SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Similar documents
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. F2 LABS Peters Road Middlefield, OH Wendy Fuster Phone: Ext.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. CISCO SYSTEMS, INC. 170 West Tasman Drive San Jose, CA Mr. Gerald Thorpe Phone:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. NATIONAL TECHNICAL SYSTEMS Boyce Road Fremont, CA Ms. Laura Bader Phone:

CERTIFICATE OF ACCREDITATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

This annex is valid from: to Replaces annex dated: Prolonged until

CERTIFICATE OF ACCREDITATION

ANSI-ASQ National Accreditation Board/ACLASS

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

CERTIFICATE OF ACCREDITATION

EMC Bayswater Pty Ltd

Annex to the Accreditation Certificate D-PL according to ISO/IEC 17025:2005

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION

Compliance Engineering Ireland Ltd

Compliance Engineering Ireland Ltd

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

CERTIFICATE OF ACCREDITATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1

IAS Accreditation Number

Overview of International Lighting Standards Steve Coyne Director, Light Naturally UNEP Consultant

STS Directory Accreditation number: STS 0009

LED Reliability and Current Standards for Measurement

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SECTION INTERIOR LIGHTING

Reflector T2 and GU10 6,000 hours

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Joint CELMA / ELC Guide on LED related standards

Test Report. Appliance EMF Testing

Challenges in SSL Design and Photometric testing Gautam Brahmbhatt, Head Technical (Verification Service)

Safety Certification of Solid-State Lighting Products. September 23, 2009 Todd Straka Director - Lighting Services

Energy Star Directional Luminaire Test Report ELEC-TECH INTERNATIONAL CO LTD. LED Downlight

Laboratory Honeywell Technology Solutions, Bangalore-EMC Lab, 19/2, Devarabisanahalli Village, K.R. Puram, Varthur Hobli, Bangalore, Karnataka

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Fluorescent Lamps - Guide for Electrical Measurements

EU Declaration of Conformity Annex

AUGUST 2016 CONTENTS:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. COLTS LABORATORIES, INC. 702 Stevens Avenue Oldsmar, FL Daryl Neely Phone: x204

EU Declaration of Conformity Annex

Fast. Precise. Versatile. UL Lighting Sciences

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

INDEX. Ⅰ. Company Overview. Ⅱ. Business Line. Ⅲ. Business Planning. Ⅳ. Appending - Certificates

S R 8 Circular LED Engine Product Specification

Navigating the Safety Certification Process for LED Lighting Products Todd Straka, Director Lighting Services

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Energy Solutions LED Accelerator Program PRODUCT QUALIFICATION REQUIREMENTS 2015

Mains-related EMC-issues associated with Lighting Equipment. P.A. Beeckman PGI/Philips Innovation Services EMC Kennismarkt Oost - October 12, 2012

Efficient Lighting MVE Infrastructure Status Report and Overview. Steve Coyne. Consultant, UNEP en.lighten

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:

Annex 7: Harmonised Standards for Products covered by Ecodesign and Energy Labelling Regulations. Page 1 of 26

10.6 Schedule of Accreditation

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

THE HIGH STRIP FIXTURE SERIES PERFORMANCE KEY FEATURES INCLUDE: LED Fixture Series for General, Direct and Indirect Illumination

EU Declaration of Conformity

EU Declaration of Conformity Annex

IEEE Wireless Personal Area Networks

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:

EU Declaration of Conformity Annex

EU Declaration of Conformity

ACMA mandated EMC standards

EU Declaration of Conformity Lampenwerk Wipperfürth

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

Hong Kong Association for Testing, Inspection and Certification Ltd. S.W.N. Ho. (Electrical Products Testing)

EU eclaration of Conformity

This is a preview - click here to buy the full publication

Solid State Lighting Sub-Assembly Interfaces for Luminaires. Andrew D. Jackson Philips Lighting Corporate Regulatory and Certification Laboratory

Product Compliance Andy Guest

Product Tests Report

EU Declaration of Conformity

Commentary from a Certification Body. Mike Violette Director American Certification Body

Transcription:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 INTERTEK TESTING SERVICES NA, INC. 5 25800 Commercentre Dr. Lake Forest, CA 92630 Mr. Jay Kogoma Phone: 949-448-4100 ELECTRICAL Valid to: December 31, 2017 Certificate Number: 2085.01 In recognition of the successful completion of the A2LA evaluation process, (including an assessment of the laboratory s compliance with A2LA s ENERGY STAR Accreditation Program requirements 1 ) accreditation is granted to this laboratory at the location listed above as well as the satellite laboratory location listed below to perform the following energy efficiency, product safety, and electromagnetic compatibility tests: Test Technology: Test Method(s) 2, 3, 4 : Product Safety ITE/Telecom (excluding Abrasion; Enclosed/Sealed Parts; CRT/High Vacuum; Flammable liquids; UV Radiation and Annex AA Mandrel) Power Transformers, Power Supplies, Reactors and Similar Products (excluding Vibration and Resistance to Tracking) Household (excluding Switches, Coated PWBs and Proof Tracking) IEC 60950; IEC 60950-1 6 ; EN 60950; EN 60950-1 6 ; UL 1950; UL 60950; UL 60950-1 6 ; CAN/CSA 60950; CAN/CSA 60950-1; AS/NZS 60950; AS/NZS 60950.1; SI 60950 Part 1; IEC 62040-1-1; IEC 62040-1-2 IEC 61558-1; IEC 61558-2-6; AS/NZS 61558.1; AS/NZS 61558.2.6 IEC 60335-1; EN 60335-1; UL 60335-1; CSA 60335-1; AS/NZS 3350 Other Household Standards IEC 60335-2-27 (excluding Radiation, toxicity and similar hazards); IEC 60335-2-82 (excluding Resistance to rusting [Salt Spray]); IEC 60335-2-41; IEC 60335-2-60; IEC 60335-2-75; IEC 60335-2-98; AS/NZS 3136, Issue:2001/06/11; Amendment No.1: 2001/11/12 and Amendment No.2: 2005/06/17 (A2LA Certificate No. 2085.01) Revised 11/28/2017 Page 1 of 13

Product Safety(cont.) Medical (excluding Expelled parts; Flammable gases and Oxygen bomb) Other Medical Standards (excluding shock and vibration) Laboratory Equipment (excluding Vicat Softening and CRT/High Vacuum) IEC 60601-1 6 ; EN 60601-1 6 ; UL 60601-1 6 ; CSA C22.2 No. 60601-1; AAMI ES60601-1; AS/NZS 3200 IEC 60601-1-1; IEC 60601-1-4; IEC 60601-1-6; IEC 60601-1-8; IEC 60601-1-10; IEC 60601-1-11 (excluding sections 4.2.2, 10.1.2, 10.1.3); IEC 60601-2-2; IEC 60601-2-3; IEC 60601-2-6; IEC 60601-2-10; IEC 60601-2-12; ISO 80601-2-12; IEC 60601-2-16; IEC 60601-2-18; IEC 60601-2-22; IEC 60601-2-25; IEC 60601-2-27; IEC 80601-2-30; IEC 60601-2-41; IEC 60601-2-49; IEC 60601-2-51; ISO 80601-2-55; ISO 80601-2-56; IEC 60601-2-57; IEC 80601-2-58; IEC 80601-2-60; ISO 80601-2-61; IEC 62304; IEC 62366 IEC 61010-1 6 ; EN 61010-1 6 ; UL 61010-1 6 ; CAN/CSA C22.2 No. 61010-1 Other Laboratory Equipment AS 61010; IEC 61010-2-010; IEC 61010-2-030; IEC 61010-2-081; IEC 61010-2-091; IEC 61010-2-101; Audio/Video (excluding Vicat Softening; Vibration Endurance; Bump; Resistors/ Switches; CRT/High Vacuum and Annex H Insulating winding wires) IEC 60065; EN 60065; UL 60065; CAN/CSA 60065; AN/NZS 60065; IEC 62368-1 Laser IEC 60825-1 Lighting (excluding Rough service luminaires, Protective measures against UV radiation, and Resistance to tracking) IEC 60598-1; EN 60598-1; ANSI/UL 1598; ANSI/UL 1598B Other Lighting Standards CAN/CSA C22.2 No. 74; CAN/CSA 250.0; IEC 60598-2-1; IEC 60598-2-2; IEC 60598-2-3; IEC 60598-2-4; IEC 60598-2-5; IEC 60598-2-6; IEC 60598-2-7; IEC 60598-2-8; IEC 60598-2-9; IEC 60598-2-11; IEC 60598-2-17; IEC 60598-2-18; IEC 60598-2-19; IEC 60598-2-22; IEC 60598-2-23; IEC 60598-2-24; IEC 60598-2-25; IEC 60968; IEC 6203; IEC 60061-1; IEC 60081; IEC 60901; IEC 61347-2-3; ANSI/IEEE C62.41.1; ANSI/IEEE C62.41.2; ANSI C78.20; ANSI C78.21; ANSI C78.23; ANSI/ANSLG C78.357; ANSI C78.376; ANSI C78.377; ANSI C78.389; ANSI/ANSLG C78.42; ANSI/ANSLG C78.43; ANSI C78.5; ANSI/ANSLG C78.81; ANSI/IEC C78.901; ANSI 79.1; (A2LA Certificate No. 2085.01) Revised 11/28/2017 Page 2 of 13

Product Safety(cont.) Other Light Standards (cont.) ANSI/ANSLG C81.62; ANSI/ANSLG C82.14 ANSI/NEMA C82.2; ANSI/ANSLG C82.11; ANSI C82.4; ANSI C82.6; ANSI C82.77; ANSI/IES RP-16; ANSI/UL 153; ANSI/UL 935; ANSI/UL 1029; ANSI/UL 1310; ANSI/UL 1574; ISO 03745; ISO 7574-4 B.2.1; LRC ACTV Test; NEMA LL9; NEMA LSD 45 Lighting Performance (cont.) CIE Pub. No. 13.3; CIE Pub No 15; IES LM-9; IES LM-10; IES LM-15; IES LM-31; IES LM-35; IES LM 40; IES LM-41; IES LM-46; IES LM-47; IES LM-49; IES LM-51; IES LM-58; IES LM-65; IES LM-66; IES LM-79; IES LM-82; IES LM-84 Photobiological IEC 62471; IEC 62471-2; EN 62471; EN 62471-2; CIE No. 63 Energy Efficiency Household Electrical Appliances: IEC 62301 Measurement of Standby Power ENERGY STAR Tests Lighting & Fans Lamps Luminaries Luminaries Supporting Test Methods(s) ENERGY STAR Program Requirements for Lamps (Light Bulbs) Ver. 1.1: Elevated Temperature Light Output Ratio; ; Run-Up Time (Supported by Lighting Performance listed above) ENERGY STAR Program Requirements for Luminaires Ver. 1.2 (Supported by Lighting Performance listed above) ENERGY STAR Program Requirements for Luminaires Ver. 2.0 (Supported by Lighting Performance listed above) ENERGY STAR Program Requirements for Lighting Luminaires Ver. 1.2: Requirement Category Methods of Measurement and Reference Documents Non-directional SSL Luminaires and Subcomponents (Table 9) Efficacy, Output, Lumen IES LM-79-08 Maintenance, CCT, CRI, Color Electrical and Photometric Measurements of Solid-State Lighting Maintenance Products (section 10 not required for non-directional or subcomponents) Power Factor ANSI C82.77-2002 Harmonic Emission Limits Related Power Quality Requirements for Lighting Equipment (A2LA Certificate No. 2085.01) Revised 11/28/2017 Page 3 of 13

Colorimetry8 Efficacy, Light Output, Lumen Maintenance, CCT, CRI, Color Maintenance, Light Source Life IES LM-82-12 Characterization of LED Light Engines and LED Lamps for Electrical and Photometric Properties as a Function of Temperature Directional Solid State Luminaires (Table 11) Zonal Lumen Distribution, Color IES LM-79-08 sections 10 and 12 Angular Uniformity, Luminaire Electrical and Photometric Measurements of Solid-State Lighting Photometry Products (Goniophotometer) Color Angular Uniformity IES LM-58-13 Guide to Spectroradiometric Measurements CCT CIE Pub. No. 15-2004 Colorimetry10 Efficacy, Light Output, Lumen Maintenance, CCT, CRI, Color Maintenance Lamps: CFL Directional (Table 16) Efficacy, Output, Center Beam Intensity, Lumen Maintenance, Lifetime, CCT, CRI Lumen Maintenance, Lifetime, Rapid Cycle Stress Test Power Factor CCT IES LM-79-08 Electrical and Photometric Measurements of Solid-State Lighting Products IES LM-66-11 Electrical and Photometric Measurements of Single-Ended Compact Fluorescent Lamps. IES LM-65-10 Life Testing of Compact Fluorescent Lamps ANSI C82.2-2002 Fluorescent Lamp Ballasts, Methods of Measurement of (includes supplements) ANSI C78.376-2001 Specifications for the Chromaticity of Fluorescent Lamps Colorimetry (A2LA Certificate No. 2085.01) Revised 11/28/2017 Page 4 of 13

Minimum Center Beam Intensity PAR and MR lamps Lumen Maintenance, Lifetime ETLOR (Elevated Temperature Light Output Ratio) Run Up Time ENERGY STAR Online CBCP Tool Tool for Calculating Minimum Center Beam Intensity for Lamps Version 1.1: Elevated Temperature Life Testing for Lamps Version 1.1: Elevated Temperature Light Output Ratio for Lamps Version 1.1: for Lamps Version 1.1: Run-up Time Lamps: CFL Omnidirectional and Decorative (Table 18) Efficacy, Output, Center Beam IES LM-66-11 Intensity, Lumen Maintenance, Electrical and Photometric Measurements of Single-Ended Lifetime, CCT, CRI Compact Fluorescent Lamps. Lumen Maintenance, Lifetime, Rapid Cycle Stress Test CCT Power Factor Efficacy, Lumen Maintenance, Lifetime IES LM-65-10 Life Testing of Compact Fluorescent Lamps ANSI C78.376-2001 Specifications for the Chromaticity of Fluorescent Lamps ANSI C82.2-2002 Fluorescent Lamp Ballasts, Methods of Measurement of (includes supplements) US DOE 10 CFR 429 Certification, Compliance, and Enforcement for Consumer Products and Commercial and Industrial Equipment US DOE 10 CFR 430 Appendix W to Subpart B Energy Conservation Program for Consumer Products Efficacy, Lumen Maintenance, Rapid Cycle Stress Test, Lifetime Colorimetry Lumen Maintenance, Lifetime Run Up Time for Lamps Version 1.1: Elevated Temperature Life Testing for Lamps Version 1.1 for Lamps Version 1.1 (A2LA Certificate No. 2085.01) Revised 11/28/2017 Page 5 of 13

Lamps: SSL Directional (Table 20) Efficacy, Output, Center Beam Intensity, Luminous Intensity Distribution, Lumen Maintenance, Lifetime, CCT, CRI, Color Maintenance, Color Angular Uniformity IES LM-79-08 Electrical and Photometric Measurements of Solid-State Lighting Products Power Factor ANSI C82.77-2002 Sections 6 and 7 Harmonic Emission Limits Related Power Quality Requirements for Lighting Equipment Colorimetry CCT ANSI C78.377-2011 Specifications for the Chromaticity of Solid State Lighting Products Minimum Center Beam Intensity PAR and MR lamps Lumen Maintenance, Lifetime Lumen Maintenance, Lifetime ETLOR ENERGY STAR Online CBCP Tool Tool for Calculating Minimum Center Beam Intensity for Lamps Version 1.1: Elevated Temperature Life Testing for Lamps Version 1.1: Ambient Temperature Life Testing for Lamps Version 1.1 Elevated Temperature Light Output Ratio for Lamps Version 1.1 Lamps: SSL Omnidirectional and Decorative (Table 22) Efficacy, Output, Center Beam IES LM-79-08 Intensity, Luminous Intensity Electrical and Photometric Measurements of Solid-State Lighting Distribution, Lumen Maintenance, Products Lifetime, CCT, CRI, Color Maintenance, Color Angular Uniformity, Power Factor ANSI C82.77-2002 Sections 6 and 7 Harmonic Emission Limits Related Power Quality Requirements for Lighting Equipment (A2LA Certificate No. 2085.01) Revised 11/28/2017 Page 6 of 13

Colorimetry Lumen Maintenance, Lifetime for Lamps Version 1.1: Elevated Temperature Life Testing Lumen Maintenance, Lifetime for Lamps Version 1.1: Ambient Temperature Life Testing for Lamps Version 1.1 ENERGY STAR Program Requirements for Lighting Luminaires Ver. 2.0: Requirement Category Methods of Measurement and Reference Documents Non-directional SSL Luminaires and Subcomponents (Table 5) Efficacy, Output, Lumen IES LM-79-08 Maintenance, CCT, CRI, Color Electrical and Photometric Measurements of Solid-State Lighting Maintenance Products (section 10 not required for non-directional or subcomponents) Efficacy, Light Output, Lumen Maintenance, CCT, CRI, Color Maintenance, Light Source Life IES LM-82-12 Characterization of LED Light Engines and LED Lamps for Electrical and Photometric Properties as a Function of Temperature Colorimetry8 Lumen Maintenance: Option 2 IES LM-84-14 Measuring Luminous Flux and Color Maintenance of LED Lamps, Light Engines, Source EPA ENERGY STAR Test Method Power Factor ANSI C82.77-10-2014 Harmonic Emission Limits Related Power Quality Requirements for Lighting Equipment Standby Power Consumption IEC 62301 Edition 2.0 2011-01 Household electrical appliances Measurement of standby power (A2LA Certificate No. 2085.01) Revised 11/28/2017 Page 7 of 13

Directional Solid State Luminaires (Table 7) Zonal Lumen Distribution, Color IES LM-79-08 sections 10 and 12 Angular Uniformity, Luminaire Electrical and Photometric Measurements of Solid-State Lighting Photometry Products (Goniophotometer) Efficacy, Light Output, Lumen Maintenance, CCT, CRI, Color Maintenance IES LM-79-08 Electrical and Photometric Measurements of Solid-State Lighting Products Colorimetry10 Color Angular Uniformity IES LM-58-13 Guide to Spectroradiometric Measurements Source EPA ENERGY STAR Test Method Power Factor ANSI C82.77-10-2014 Harmonic Emission Limits Related Power Quality Requirements for Lighting Equipment Standby Power Consumption 12 IEC 62301 Edition 2.0 2011-01 Household electrical appliances - Measurement of standby power LampsV1.0: CFL Directional Lamps (Table 11) Efficacy, Output, Center Beam IES LM-66-11 Intensity, Lumen Maintenance, Electrical and Photometric Measurements of Single-Ended Lifetime, CCT, CRI Compact Fluorescent Lamps. Lumen Maintenance, Lifetime, Rapid Cycle Stress Test IES LM-65-10 Life Testing of Compact Fluorescent Lamps Colorimetry Lumen Maintenance, Lifetime for Lamps Version 1.0: Elevated Temperature Life Testing ETLOR (Elevated Temperature Light Output Ratio) for Lamps Version 1.0: Elevated Temperature Light Output Ratio for Lamps Version 1.0: Run Up Time for Lamps Version 1.0: Run-up Time (A2LA Certificate No. 2085.01) Revised 11/28/2017 Page 8 of 13

Lamps V1.0: CFL Omnidirectional and Decorative Lamps (Table 13) Efficacy, Output, Center Beam IES LM-66-11 Intensity, Lumen Maintenance, Electrical and Photometric Measurements of Single-Ended Lifetime, CCT, CRI Compact Fluorescent Lamps. Lumen Maintenance, Lifetime, Rapid Cycle Stress Test CCT IES LM-65-10 Life Testing of Compact Fluorescent Lamps ANSI C78.376-2001 Specifications for the Chromaticity of Fluorescent Lamps Lumen Maintenance, Lifetime Elevated Temperature Life Test ENERGY STAR Program Requirements Product Specification for Lamps Version 1.0: Elevated Temperature Life Testing for Lamps Version 1.0: Run Up Time for Lamps Version 1.0: Run-up Time LampsV1.0: Solid State LED Directional Lamps (Table 15) Efficacy, Output, Center Beam IES LM-79-08 Intensity, Luminous Intensity Electrical and Photometric Measurements of Solid-State Lighting Distribution, Lumen Maintenance, Products Lifetime, CCT, CRI, Color Maintenance, Color Angular Uniformity Colorimetry Lumen Maintenance, Lifetime for Lamps Version 1.0: Elevated Temperature Life Testing Lumen Maintenance, Lifetime for Lamps Version 1.0: Ambient Temperature Life Testing ETLOR for Lamps Version 1.0: Elevated Temperature Light Output Ratio (A2LA Certificate No. 2085.01) Revised 11/28/2017 Page 9 of 13

LampsV1.0: Solid State LED Directional Lamps (Table 15, cont.) for Lamps Version 1.0: Lamps: Solid State LED Omnidirectional and Decorative Lamps (Table 17) Efficacy, Output, Center Beam IES LM-79-08 Intensity, Luminous Intensity Electrical and Photometric Measurements of Solid-State Lighting Distribution, Lumen Maintenance, Products Lifetime, CCT, CRI, Color Maintenance, Color Angular Uniformity Colorimetry Lumen Maintenance, Lifetime for Lamps Version 1.0: Elevated Temperature Life Testing Lumen Maintenance, Lifetime for Lamps Version 1.0: Ambient Temperature Life Testing for Lamps Version 1.0: On the following products or types of products: Industrial, Scientific, Medial (ISM), Information Technology Equipment (ITE), Audio/Video for Professional Use, Intentional Radiators, Telecommunications, Appliances, Power Tools, Photovoltaic Modules, and Unintentional Radiators. 1 A2LA provides accreditation to the U.S. EPA s Conditions and Criteria for Recognition of Laboratories for the ENERGY STAR Program by verifying an organization s compliance to A2LA document R222 - Specific Requirements - EPA ENERGY STAR Accreditation Program and to the related test methods listed above Accreditation by A2LA does not infer Recognition by the EPA for ENERGY STAR testing. Please verify this organization s recognition status at the EPA s website, located at http://www.energystar.gov/index.cfm?fuseaction=recognized_bodies_list.show_rcb_search_form 2 When the date, revision or edition of a test method standard is not identified on the scope of accreditation, the laboratory is required to be using the current version within one year of the date of publication, per part C., Section 1 of A2LA R101 - General Requirements- Accreditation of ISO-IEC 17025 Laboratories. (A2LA Certificate No. 2085.01) Revised 11/28/2017 Page 10 of 13

3 For Product Family Standards listed on this scope of accreditation, the laboratory is found to be compliant with all test methods referenced within the Product Family Standard. As such, if outdated versions of the specific test methods are identified by the Product Family Standards listed on this scope of accreditation, it is not necessary to explicitly list the outdated versions of the specific test methods on the scope. In addition, the laboratory is capable of issuing accredited test reports to the outdated versions of the specific test methods although the outdated versions are not listed on this scope of accreditation. 4 The laboratory is only accredited for testing activities outlined within the test methods listed above. Reference to any other activity within these standards, such as risk management or risk assessment, does not fall within the laboratory s accredited capabilities. 5 This accreditation covers testing performed at the main laboratory listed above, and the satellite laboratory listed below. 25791 Commercentre Dr. Lake Forest, CA 92630 Test Technology: Test Method(s) 2, 3, 4 : Emissions Radiated & Conducted (3 meter Semi-Anechoic Chamber) CFR 47 FCC, Part 15B (using ANSI C63.4-2009 and 2014) and Part 18 (using MP-5); IEC/CISPR 11 6 ; EN 55011; AS/NZS CISPR 11 6 ; KN 11; CAN/CSA-CEI/IEC CISPR 11 6 ; CNS 13803; IEC/CISPR 13; EN 55013; AS/NZS CISPR 13; CNS 13439; CISPR 14-1 (excluding clicks); EN 55014-1 (excluding clicks); KN 14-1 (excluding clicks); AS/NZS 1044; AS/NZS CISPR 14; CNS 13783-1; IEC/CISPR 22; EN 55022 6 ; AS/NZS CISPR 22; SI 961 Part 6.1; CSA/CSA CISPR 22; KN 22; CNS 13438 (1-6GHz); HCTA 1007 (ISM Equipment); HCTA 1035 (Low Power Devices) Current Harmonics IEC/EN 61000-3-2 6 ; KN 61000-3-2 Flicker & Fluctuations IEC/EN 61000-3-3 6 ; KN 61000-3-3 Transmitters & Receivers Immunity CFR 47 FCC Part 15, Subpart C (using ANSI C63.10-2013); Subpart E (using ANSI C63.10-2013, excluding DFS testing); DGT LP0002; RSS-Gen; RSS-102 (excluding SAR testing); RSS-210; RSS-247 (excluding DFS testing); RSS-310; ETSI EN 301 893 (excluding DFS testing); ETSI EN 300 220-1; ETSI EN 300 220-2; ETSI EN 300 330-1; ETSI EN 300 330-2; ETSI EN 300 440-1; ETSI EN 300 440-2 Electrostatic Discharge IEC/EN 61000-4-2 6 ; KN 61000-4-2 Radiated Immunity IEC/EN 61000-4-3 6 ; KN 61000-4-3 Electrical Fast Transient/Burst IEC/EN 61000-4-4 6 ; KN 61000-4-4 (A2LA Certificate No. 2085.01) Revised 11/28/2017 Page 11 of 13

Immunity (cont.) Surge Immunity IEC/EN 61000-4-5 6 ; KN 61000-4-5 Conducted Immunity IEC/EN 61000-4-6 6 ; KN 61000-4-6 Power Frequency Magnetic Field Immunity Voltage Dips, Short Interruptions, and Line Voltage Variations IEC/EN 61000-4-8 6 ; KN 61000-4-8 IEC/EN 61000-4-11 6 ; KN 61000-4-11 Generic & Product Specific EMC Standards Radio Equipment EN 301 489-1; EN 301 489-3; EN 301 489-17 Audio/Video IEC/EN 55103-1; IEC/EN 55103-2 Multimedia Equipment CISPR 32; EN 55032; KN 32; AS/NZS CISPR 32 (excluding A/V IO port emission voltage test) Household IEC/EN 55014-2; KN 14-2; IEC 62233 ITE/Telecom IEC/CISPR 24; EN 55024; KN 24; SI 961 Part 6.2; ICES-003; VCCI V-3 (up to 6 GHz); EN 301 489; EN 300 386 Laboratory IEC/EN 61326 Medical IEC/EN 60601-1-2 6 Generic IEC/EN 61000-6-1; KN 61000-6-1; IEC/EN 61000-6-2; KN 61000-6-2; IEC/EN 61000-6-3; KN 61000-6-3; IEC/EN 61000-6-4; KN 61000-6-4 Lighting IEC/EN 61547; IEC/EN 55015; CISPR 15; KN 15 Photovoltaics Photovoltaic IEC 60891; IEC 60904-1; IEC 60904-2; IEC 60904-3; IEC 60904-5; IEC 60904-6; IEC 60904-7; IEC 60904-8; IEC 60904-9; IEC 60905-10; IEC 61215 (hail test 25mm balls only); IEC 61345; IEC 61646; IEC 61721; IEC 61730-1; IEC 61730-2; UL 1703; UL 61730-1; UL 61730-2; IEC TS 62727 6 This laboratory meets A2LA R104 General Requirements: Accreditation of Field Testing and Field Calibration Laboratories for these tests or calibrations. (A2LA Certificate No. 2085.01) Revised 11/28/2017 Page 12 of 13

Testing Activities Performed in Support of FCC Declaration of Conformity and Certification in Accordance with 47 Code of Federal Regulations and FCC KDB 974614, Appendix A, Table A.1: Rule Subpart/Technology Test Method Maximum Frequency Unintentional Radiators Part 15B ANSI C63.4:2014 40 GHz Industrial, Scientific, and Medical Equipment Part 18 FCC MP-5 (February 1986) 40 GHz Intentional Radiators Part 15C ANSI C63.10:2013 40 GHz U-NIII without DFS Intentional Radiators Part 15E ANSI C63.10:2013 40 GHz (A2LA Certificate No. 2085.01) Revised 11/28/2017 Page 13 of 13

Accredited Laboratory A2LA has accredited INTERTEK TESTING SERVICES NA, INC. Lake Forest, CA for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated 8 January 2009). Presented this 7 th day of December 2015. President and CEO For the Accreditation Council Certificate Number 2085.01 Valid to December 31, 2017 Revised November 28, 2017 For the tests to which this accreditation applies, please refer to the laboratory s Electrical Scope of Accreditation.