IMPROVE SAFETY WITH ARC FLASH LABELING COMPLY WITH THE 2015 NFPA 70E REGULATIONS

Similar documents
2012 Edition. Tech Topics: Standards & Codes. Note 4, Issue 1. Points of Interest: Introduction. Background. Changes to Definitions in Article 100

SUMMARY: Policy Title: Electrical Safety Work Practice Program. Policy Number: UNIV-EHS 430 Policy Approved: January 2014

NFPA 70E Edition Update

Electrical Safety for Facility Managers and Building Owners

NFPA 70E Elevates Safety. with Heightened Risk Awareness

Guide to Compliance with the Electrical Workplace Safety Standards in the United States

Electrical Hazards and NFPA-70E: Protecting Your Employees

HESNI ANNUAL CONFERENCE May 3, 2012 Aramark Conference Center, Downers Grove

Electrical Safety Compliance: NFPA 70E

PROTECTING AGAINST ARC FLASH HAZARDS

IEEE Std IEEE Recommended Practice for Electrical Installations on Shipboard Safety Considerations

NFPA 70E Electrical Safety in the Workplace

NECA. Standard for Electrical Safety in the Workplace

Arc Flash Analysis. Arc flash hazard analysis is required to determine the risk to personnel, warn them of the

Applying the 2012 NFPA 70E. Arc Flash Standard

NECA & Salisbury Assessment Solutions Partnership

Your Global Automation Partner. Minimizing Arc Flash Exposure in Industrial Applications. White Paper - W1000

NFPA 70E. Electrical Safety in the Workplace. KTR Associates. Joseph Deane, PE. Engineering Solutions

NFPA 70E Electrical Safety & Arc Flash Training

NECA S System Approach to Electrical Safety for NFPA 70E

NECA S System Approach to Electrical Safety for NFPA 70E

Changes to NFPA 70E. - The Role of PdM &Safe PdM Work Practices. Tim Rohrer Exiscan LLC

NFPA 70E Standard for Electrical Safety in the Workplace. EEI Safety and Health Meeting May 2011

May is National Electrical Safety Month, an AND THE ELECTRICAL INSPECTOR. by Mark Hilbert and Laura L. Hildreth

Arc Flash Protection Training - NFPA 70e Electrical Safety

Arc Flash Analysis: IEEE Method versus the NFPA 70E Tables July 2017 / 1910DB1702

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

SEL Arc-Flash Solutions

SALISBURY ASSESSMENT SOLUTIONS

SEL Arc-Flash Solutions

T22 - Arc Flash Hazards and Arc Resistant Equipment- Understanding the Standards

Short Circuit Current Rating

Protection from Electric Shock and Arc Flash. Meeting OSHA Regulations and NFPA 70E Standards.

Electrical Safety Program

DEMYSTIFYING FR CLAIMS: AN ERGODYNE WHITE PAPER

Safety Meeting Topic #37 NFPA 70E What is it?

NFPA 70E Update: Key Changes You Need to Know to Assure Compliance

PREVIEW COPY. Table of Contents. Annexes and Supplemental Materials Lesson One Article 90: Introduction and Purpose... 3

2014 National Electrical Code & NFPA 70E/Arc Flash

Document Number: ELECTRICAL SAFETY ZSD-HMSAFESA Issue Date: July 4, 2017 Revision #: 3 Next Review Date: July 4, 2022

6/23/ National Electrical Contractors Association and Intec, Inc.

Understanding 2015 Changes to NFPA 70E Safety-related work practices and maintenance requirements mandate more robust electrical safety programs for

PREPARING YOUR ORGANIZATION FOR NFPA 70E 2015

SECTION C. Section Cable Trays for Electrical Systems: Additional identification requirements for cable tray systems.

Rutgers Environmental Health and Safety (REHS)

Janine Bain Rhonda Lewis Harland Hirst Sandra Olive David Johnson Edward Maurer Kathy Felsten Joe Halle

How to reduce exposure to arc flash hazards

Webinar November 12, 2014

VeriSafe Absence of Voltage Tester The safe way to verify the absence of voltage

PANELBOARDS & BUILDING DISTRIBUTION

Implementing an Energized Electrical Work Program. SESHA Hill Country Chapter. Brett Jay Davis, PE Zephyr Environmental Corporation

COMPLIANCE without compromise SAFETY without sacrifice YOUR RESULTS MATTER

How many time has your company been asked by an owner or customer to work on equipment energized?

Brian McCauley December 2017

Compliance without compromise Safety without sacrifice

Electrical Preventive Maintenance (EPM) Program

Centennial Energized Electrical Work Permit Instructions

The safe way to verify the absence of voltage.

Brown University Revised June 29, 2012 Facilities Design & Construction Standards SECTION ELECTRICAL DESIGN CRITERIA

General Safety Training

Section: TABLE OF CONTENTS Accident Prevention Signs, Tags, Labels, Signals, Piping System Identification and Traffic Control

ENERGY CONTROL LOCKOUT/TAGOUT PROGRAM PLAN

Labeling to Article 690 of the National Electrical Code Routing and Protecting PV Cables

Your Turnkey Solution for Mitigating the Hazards of Arc Flash Incidents in the Workplace

Electrical Management

Welcome DISCLAIMER. Testing Electric Fire Pumps You Need to Understand the Arc Flash Hazard 5/1/ NFPA Conference & Expo

Arc Flash Codes & Compliance: What You Need to Know to Deliver Both Protection and Performance

PGR-8800 TECHNICAL FAQ

General Safety Training

Electrical Safety Program

Regional Training. Seminar. » EasyPower Hands-On» Protective Device Coordination» Arc Flash Hazard Analysis. March 12-16, 2018 Austin, TX

You and OSHA. What and How To Comply. PRESENTED BY: Joan M. Spencer Compliance Assistance Specialist Tampa Area Office

UNDERSTANDING 2015 CHANGES TO NFPA 70E

NFPA 70E Arc Flash Considerations for MV Equipment. By: Dominik Pieniazek, P.E. HV Engineering, LLC

Installation Instructions

Installation Instructions

SALAMA SAFETY SIGNS SALAMA SAFETY SIGNS SAFETY SIGNS PHOTOLUMINESCENT

Arc Fault Detection Devices (AFDDs) Protecting People and Property

Directive on Laser Safety. NRC Occupational Safety and Health Manual

ELECTRICAL SAFETY GUIDELINE

ISO INTERNATIONAL STANDARD. Safety identification Escape and evacuation plan signs. Identification de sécurité Plans d'évacuation et de secours

OSHA Subpart F Fire Protection and Prevention

UNDERSTANDING 2015 CHANGES TO NFPA 70E

SECTION IDENTIFICATION FOR ELECTRICAL SYSTEMS

Safety Manual: Emergency Response

West Virginia University Laser Safety Program

Occupational Safety Next Review Date: 12/20/17. Scope: University Wide Original Creation Date: 2009

A. Product Data: For each electrical identification product indicated. B. Comply with 29 CFR and 29 CFR

A. Shop Drawing submittals shall include, but not be limited to, the following:

Installation Instructions

INITIAL ELECTRICAL ASSESSMENT REPORT (EAR)

Navigating the Safety Certification Process for LED Lighting Products Todd Straka, Director Lighting Services

EQUIVALENT INITIAL ELECTRICAL SAFETY ASSESSMENT

Development of standards for MV Switchgear for Arc Flash protection. ABB Group May 20, 2013 Slide 1

17 TH APRIL 2017 Switch Board Monitoring Protecting Switchboard. Courtesy of ABB. Paul Lee

MACHINE GUARDING. Hazards of Unguarded Machines. Occupational Safety and Health Regulations (OSHA)

Remote Relay Module (RRM)

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. AND BONDING. 2010, The McGraw-Hill Companies, Inc.

Fluke IR Windows Easier NFPA 70E compliance without compromising on product performance.

State of North Carolina Department of Environment and Natural Resources Division of Waste Management. Safety and Risk Management Program

Transcription:

IMPROVE SAFETY WITH ARC FLASH LABELING COMPLY WITH THE 2015 NFPA 70E REGULATIONS By Thomas Smith, Product Specialist, Brady Corporation Last updated: February, 2015

The Occupational Safety and Health Administration (OSHA) is citing and fining employers for failure to protect employees from the dangers of arc flash. For guidelines on how to protect employees, OSHA refers employers to the NFPA 70E standard, Standard For Electrical Safety In the Workplace. This document provides information on the most current arc flash labeling requirements, as well as best practices for creating and maintaining such labels. In the 2015 version of the NFPA 70E standard, arc flash labeling requirements are covered under Article 130.5(C) and 130.7(E)(1). Additional labeling requirements are also included in Article 110.16 of the 2014 version of the National Electric Code (NEC). This whitepaper will provide guidance for complying with both standards. What Needs to be Labeled? Arc flash labeling is the responsibility of the employer, not the manufacturer or installer of the equipment. The NEC provides the following examples of electrical equipment that must be field marked with a warning label: Switchboards Panel boards Industrial control panels Meter socket enclosures Motor control centers This is not an all-inclusive list. Labeling is required for any piece of electrical equipment that is likely to require examination, adjustment, service or maintenance while energized, creating the potential for an arc flash incident to occur. Thus, many employers are also labeling bus ducts and other electrical equipment not specifically called out in the NEC. Any modifications or renovations to electrical equipment that will change data on the label will require an updated arc flash risk assessment and label according to the 2015 NFPA 70E standard. At minimum, the safety program needs to be audited at intervals not to exceed 3 years and arc flash risk assessment shall be periodically reviewed at intervals not to exceed 5 years. Equipment installed prior to the 2002 NEC provision does not require a label. However, should it be modified or upgraded in any way, then a label must be affixed. In fact, an OSHA representative has stated that even changing a fuse or circuit breaker could be considered a modification that would require labeling. Labels applied prior to September 30, 2011 are acceptable if they contain the available incident energy or required level of PPE. From a safety perspective, the hazard is the same regardless of when the equipment was installed. Consequently, most employers are simply labeling all the appropriate equipment, regardless of when it was installed. The NEC requirement states that the marking must be in a location that is clearly visible to qualified persons before they begin work. Typically, the label is placed outside the panel or enclosure door. In some cases, companies choose to put the label inside the door to protect it from harsh environments; however, this should only be done if the door must be opened (allowing the label to be seen) in order to remove the panel face or enclosure. The key point is that the label should be easily noticeable by workers before they may be exposed to any potentially dangerous live parts. What Needs to Appear on the Label? Article 110.16 in the NEC states that relevant electrical equipment shall be field marked to warn qualified persons of potential electric arc flash hazards. In Article 130.7(E)(1), the NFPA 70E standard further notes that the design and formatting of the labels should conform with ANSI Z535 Series of Standards For Safety Signs & Tags. Thus it is recommended that the header, message and pictogram, if used, be formatted according to ANSI standards. Currently there is not a widely-accepted symbol for indicating an arc flash hazard. Brady offers stock arc flash labels both with and without a symbol, employing a pictogram composed of a red explosive graphic inside of a triangular border for this purpose. Neither the NFPA 70E nor the NEC requirements specify whether to use a Danger or Warning header; however, NFPA 70E does recommend identifying those situations in which there is an extreme hazard to the worker. A commonly used guideline is to use a red Danger header when the voltage is over 600 volts or when the incident energy is over 40 cals/cm 2. Many employers have also Page 2

standardized to using the Danger signal word to indicate a situation where serious injury or death WILL occur. If it is less than that threshold, an orange Warning header is used. The employer has the final decision on which words appear on the labels, but it is imperative that consistency be maintained on all the labels throughout the facility. It is also important to note that arc flash labels must be able to withstand their usage environment. This means that the print should not fade and the adhesive should be aggressive enough to avoid peeling. When necessary, an overlaminate should be applied to protect the printed surface from harsh chemicals and exposure to sunlight. Once an arc flash risk assessment has been conducted, in which the arc flash boundary, the incident energy at the working distance and the personal protective equipment required has been determined, Article 130.5 (C) in the 2015 edition of NFPA 70E further dictates that the label must contain these important elements: 1. Nominal System Voltage A value assigned to a circuit or system for the purpose of conveniently designating its voltage class (i.e. a 12-volt battery, 24-volt system or 480-volt electrical panel). 2. Arc Flash Boundary The distance at which an electrical arc can flash outward, which may endanger employees working on electrical equipment, where up to 2nd degree burns are likely to occur. Among key changes from 2012 standards, the Prohibited Approach Boundary has been deleted. No additional protective equipment was required when crossing the prohibited boundary after the LIMITED and RESTRICTED boundaries were previously implemented, therefore this delineation was removed. Also the hazard/ risk category 0 has been deleted because because the new PPE table only specifies for work within the arc flash boundary. Additional Boundary Requirements: Conductive Articles of Jewelry and Clothing - Watchbands, bracelets, rings, key chains, necklaces, metal frame glasses, etc. shall not be worn within the restricted approach boundary. Working Space - Shall not be used for storage. Space shall be kept clear to permit safe operation and maintenance. Barricades - When the arc flash boundary is greater than the limited approach boundary, barricades shall not be placed closer than the arc flash boundary. Note: Depending on the application the arc flash boundaries may extend to the other side of the wall. Insulated Tools - Employees shall use insulated tools when working inside the restricted approach boundary of exposed energized electrical conductors. 3. At least one of the following: a. Available incident energy and the corresponding working distance (An incidental energy analysis is used to help predict the incident energy of an arc flash for a specified set of conditions. Incident energy is the amount of energy impressed on a surface, a certain distance away from the source, generated during an electrical arc event. This should be measured and labeled in cal/cm 2 ). Or the arc flash PPE category in Table 130.7(C)(15)(A) (b) or 130.7(C)(B) for equipment. But not both. OR b. Minimum arc rating of clothing (This also should be expressed in cal/cm 2. Arc rated clothing indicates it has been tested for exposure to an electrical arc. This was formally expressed as flame resistant in previous NFPA editions). OR c. Site specific level of PPE. Page 3

Finally, some safety-conscious employers go one step further by including shock hazard information on the label. After all, as long as you are going through the trouble to warn employees of arc flash hazards, why not provide similar safety guidance for the other electrical hazard shock? These labels provide complete arc flash hazard information, plus shock hazard information on the applicable voltage, approach boundaries, and insulated glove and tool requirements. Brady Write-On Labels Brady provides several versions of stock arc flash labels, which can be written on using a permanent pen or marker. The labels shown at the right meet all current NEC and NFPA 70E requirements, including the updated 2015 version, and are available with either Danger or Warning headers. These labels include write-in fields for indicating the arc flash boundary incident energy and corresponding working distance, nominal system voltage, arc rating of clothing, PPE hazard category and check boxes for designating the required PPE. This type of extensive label provides employees with the most complete information for protecting themselves from arc flash hazards. Labels With Pre-Printed Arc Flash PPE Category and PPE Lists Brady also offers pre-printed arc flash labels with the arc flash PPE category and a list of the required PPE, relieving the employer from having to hand-write this information. As with the check box labels, a version for both arc flash and shock hazards is available. Make-it-Yourself Arc Flash Labels Large facilities may need to create hundreds - if not thousands - of customized arc flash labels. In this case, Brady s industrial printing systems are the ideal solution. This option avoids the time and trouble associated with handwriting many labels and it allows labels to be printed in batches as the project transitions from one area of the plant to another. Brady s printer options for creating arc flash labels include the IP Thermal Transfer Printer, the PR Plus Printer, BBP 31, BBP 33 and BBP 85 Sign and Label printers. Brady label materials are designed for industrial, smooth or rough surfaces and outdoor use and employ thermal-transfer printing to provide the optimum in UV, chemical and abrasion resistance. For single color printers, label materials with a pre-printed colored ANSI Danger or Warning header are available; this allows users to print only the black text while still creating a color label that meets the ANSIZ535 standard for safety signs and labels. If you want to print multiple colors, Brady has printer models with that capability as well, where the printer will produce the entire multi-color label on a white label stock. In addition, MarkWare and LabelMark software applications include preformatted arc flash templates that allow users to quickly fill in the blanks on their PC, then send the file to a Brady printer to print. The templates can also be easily customized to include a logo or other company-specific information. When large quantities of labels need to be created and managed, users often prefer to store the label information in a spreadsheet. Brady software allows this data to be downloaded and automatically merged into the label creation software for output to the Brady printer. Page 4

Finally, many companies have begun using commercial power management software from companies such as SKM, EasyPower and ETAP to assist in mapping out their electrical system and creating one-line diagrams. In recent years, many of these third-party applications have added arc flash analysis modules which use the one-line information to calculate incident energy values, flash protection boundaries and other pertinent arc flash variables. Brady software and printing systems can also be used throughout the plant for other forms of safety and facility identification, such as pipe marking, equipment identification, chemical labels, barcode labels and inventory labels. This provides an even greater and faster return on your system investment, since it can have ongoing, beneficial use for a variety of purposes long after the primary arc flash labeling project is complete. Your Opportunity to Reduce the Risk With the rising frequency of reported arc flash accidents, and the potential for serious injury or death, arc flash deserves the concern it is generating within OSHA and the safety industry. To increase safety and ensure compliance throughout the workplace, it is essential to learn and identify arc flash hazards in your facilities. Train your employees in safe work practices and utilize the labels and awareness aids that are available to you to keep the message in the forefront of your workers minds, and reinforce the desired behavior in your own facility. Brady can help you achieve these goals with industry-leading products, training resources, services and more. For more information on arc flash label solutions, go to www.bradyid.com/arcflash. Or call 1-888-272-3946 to arrange for a Brady salesperson to visit your site. Page 5