AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS Series HEAT PUMP PEH-7, 8, PEH-7 PEH-8 PEH- Cooling capacity () 18.8 22.0 28.8 Heating capacity () 19.4 22.0 28.8 High Efficiency, Powerful Heating and Cooling
7/8/HP Models Lined Up for Coercial & Residential Application New Model Outdoor Unit Dramatically Reduces the Installation Space The installation space for each outdoor unit, including service space, has been reduced to 0.65m 2. Quiet Operation The low operating noise of the newly designed outdoor units (8/HP) marks the industry leading level. Noise level (db) New model (Cooling/Heating) Previous model PUH-7MYF 59/59 65 PUH-8MYF 59/59 65 PUH-MYF 59/60 65 Saltproof Fin Treatment of Outdoor Unit Meets Various Installations Wide Operation Range Newly developed Fan Controller expands the operating ambient temperature. Outdoor Unit New MYF model 1180 Standard Finguard at Air Intake Side Enhances the Product Safety 50-5 - -15 Cooling 550 Operating ambient temp. (Outdoor) Heating Enable to Change Fan Speed(7/8HP) 7 8 External static pressure (Pa) 125 125 150 Noise level (db : at Lo-notch) Indoor Unit By introducing new 2-stage Fan Motor in the indoor unit, the fan speed can be changed (Hi/Lo) by the controller for extra comfort. (PEH- Fan speed is preset at high speed.) Affordable External Static Pressure To provide flexibility for duct extension, branching and outlet configuration. Automatic Cooling/Heating Changeover Operation for More Comfort Extra Quiet Operation Along with the innovative noise suppression features found on other Mitsubishi Electric air conditioners, the PEH Series incorporates an improved sirrocco fan to reduce noise. Limitations on Piping Length Indoor H L 50m H m L Outdoor 7 8 55 56 59 Indoor L 50m H m L Outdoor H
Enhanced System Control and Operation Ease Wiring Needs Halved Remarkable SavinginCostandLabor Interactive system management, incorporated using an original technology we call "A-Control," is provided by a single 3-wire power/control cable connecting system components. In addition, a non-polarized, dual core wire employed for the remote control line further facilitates installation work. Full System Diagnosis "A-Control" interactivity between indoor and outdoor units enables the system's self-diagnostic function to be used for examining the entire system; even abnormalities in the outdoor unit will be shown on the remote controller display. Imporvements in display details make more accurate and timely responses for maintenance and repair possible. Remote display alternately shows error code and corresponding model number Power supply wiring to outdoor unit (3-phase) 3-core transmission cable Power supply wiring to indoor unit Remote controller Transmission line (2-core) PEH-7, 8 : Single phase PEH- : 3-phase Flexible Function Setting from Remote Controllers Prepared as Standard Remote Controllers can now be used for the selection and setting of functions such as fan speed, air outlets, etc. which were previously set from the indoor unit base board. Setting changes can also be made very easily at the installation stage. LED CLOCK ERROR CODE OA UNIT ADDRESS NOT AVAILABLE Error code CHECK MODE Self diagnostic target unit address Alternate display Error delection article Building Management System Compatibility "A-Control" technology offers compatibility so that systems of the series can operate as part of the MELANS building air conditioning management system. Once connected by a special adapter (optional), the systems respond to coands given from the MELANS control center. The remote controller can also be used for general system control. M-NET (MELANS) connection Man machine interface (G-50A) Power supply unit PAC-SC50KUA (optional) City Multi Y outdoor unit Local remote controller CLOCK Local remote controller ERROR CODE OA UNIT ADDRESS NOT AVAILABLE CHECK MODE Corresponding model number Set temperature display Room temperature display Adapter PAC-SF48MA-E (optional) Outdoor unit A-cotrol remote controller Operation mode switch Operation lamp Filter sign reset switch Test run switch Check switch Ventilation (Lossnay) mode setting switch (Control linked operation with Lossnay) Wired remote controller < PAR-MAA-E > Efficient Lossnay Ventilation Management The Lossnay ventilation system can be easily connected to and controlled by the interactive "A-Control" system using an adapter. The combined interlocking system offers the ability to remove unclean air from indoor environments while adding 25% savings in operating costs for ventilation compared to conventional systems. Independent control of the Lossnay is also possible. Lossnay operation managed by "A-Control" Use of Two Remote Controllers per Group Thanks to the employment of "A-Control", the remote controller can be installed up to two sets per system. This greatly upgrades operability in residential and coercial application. PZ-53ADF-E LGH-++RS 2 Lossnay connecting cable (PZ-53ADF-E Accessories) Remote controller
Specifications Model name Service reference Power supply Indoor Outdoor Total cooling capacity (Gross) BTU/h Sensible cooling capacity (Gross) BTU/h Total cooling capacity (Net) BTU/h Total heating capacity (Net) BTU/h Capacity step % Refrigerant Refrigerant charge kg Refrigerant control Model name Service reference External finish Height Dimension Width Depth Net weight kg Indoor coil Indoor fan Indoor fan motor No. x Motor output CMM Indoor fan airflow (Lo-Hi) CFM L/S External static pressure Aq Pa Sound pressure level db(a) Drain connection Outdoor unit Model name Service reference External finish Color Height Dimension Width Depth Net weight kg Compressor No. x Motor output Outdoor coil Outdoor fan Outdoor fan motor No. x Motor output CMM Outdoor fan airflow CFM L/S Sound pressure level (Cooling/Heating) db(a) Protection devices PEH-7MYB PEH-8MYB PEH-MYB PEH-7MYB-EU PEH-8MYB-EU PEH-MYB-EU ~ 2~2V 50Hz 3N~ 380~415V 50Hz 3N~ 380~415V 50Hz 18.8 22.0 28.8 64,0 75,0 98,0 16,0 19,000 24,800 16.2 18.7 24.8 55,0 63,800 84,600 14,000 16,0 21,0 18.1 21.1 27.7 61,800 72,000 94,500 15,600 18,0 23,900.1 22.0 28.8 68,600 75,0 93,800 17,0 19,000 24,800 0 0 R-22 5.7 6.6 9.9 Capillary tube PEH-7MYB PEH-8MYB PEH-MYB PEH-7MYB-EU PEH-8MYB-EU PEH-MYB-EU Galvanized steel 428 1,380 1,580 650 67 70 84 Cross fin coil Centrifugal (plastic) Direct drive 1-pahse induction motor 3-phase induction motor 1x0.21 1x0.4 1x1.0 48/60 56/70 90 1,695/2,119 1,978/2,472 3,179 800/1,000 933/1,167 1,500 12.5 15 125 150 55 56 59 25.4 PUH-7MYF PUH-8MYF PUH-MYF PUH-7MYF-EUS PUH-8MYF-EUS PUH-MYF-EUS Acrylic resin coating MUNSELL 5Y 8/1 1,480 1,180 550 (642) 188 (193) *5 221 (226) *5 Hermetic line start 1x5.0 1x5.5 1x7.5 Cross fin coil (Saltproof treatment) Propeller-direct drive 3-phase induction motor 2 x 0.09 2 x 0.15 167 190 5,898 6,711 2,783 3,167 59/59 59/60 High pressure switch, Freeze & frost protection fuse, Overcurrent relay (compressor& indoor fan), Internal thermostat (compressor, indoor fan & outdoor fan) Note : 1. Cooling and heating capacities are based on the following conditions; Cooling : Indoor: 27 CDB, 19 CWB, Outdoor: 35 CDB Heating : Indoor: CDB, Outdoor: 7 CDB, 6 CWB Cooling and heating capacities are based on 5m pipe length. 2. Refrigerant charge volumes are factory charged (at 5m piping length). Refrigerant is enclosed in the outdoor unit. 3. The measuring point of the sound pressure level is 1m from the unit surface. 4. Specifications subject to change without notice. 5. Figure in ( ) indicates the dimension with built-in air outlet guide.
Outline Dimensions (Unit : ) Model PEH-7, 8MYB 4 31 24-3.1 holes 12 1 1 1 1 1 1 1 34 1 31 duct flange 423 344 95 152 156 650 50 5 70 15 15 33 562 46 45 1 1 1 1 1 1 1 45 1380 13 12 00 1 1 1264 Model PEH-MYB 4 26-3 holes 12 1 1 1 1 1 1 1 1 1 34 duct flange 0 0 Control box 22-3.1 holes 1280 0 199 131 25.4 (1 braze) 15.88 (5/8 braze) sensor 42 1 1 42 2 116 25 0 0 25 Drain : Rc 1 382 duct flange Controller ( side) Connect wire (PEH-PUH) ( side) 5 428 55 55 156 Duct earth point (Both duct side) Power supply ( side) 15 4-12 holes (For hanging bolt M) 14 250 98 Control box 423 1480 0 22-3 holes 131 Refrigerant pipe 28.6 (1 braze) 344 95 152 156 15.88 (5/8 braze) 650 50 5 70 15 15 42 1 1 42 2 116 25 0 0 25 33 sensor 562 Drain : Rc 1 382 Controller ( side) Connect wire (PEH-PUH) ( side) 5 duct flange 428 55 55 156 46 45 1 1 1 1 1 1 1 1580 15 14 00 2 1464 Duct earth point (Both duct side) Power supply ( side) 45 2 15 14 250 98 4-12 holes (For hanging bolt M) Model PUH-7, 8, MYF (1212) (490) (490) (1212) Detail A Detail B 4-15 holes (Hanging) 4-x holes (For mounting anchor bolt M8) 490 (Bolt pitch) A 1212 (Bolt pitch) 550 1180 B Control box 1480 15.88(5/8 flare) 7, 8MYF : 25.4(1 flange) MYF : 28.6(1-1/8 flange) 142 Wiring hole 170 95
Outline Dimensions Model PUH-7, 8, MYF (with optional air outlet guide) (Unit : ) (490) (1212) 4-15 holes (Hanging) 4-x holes (For mounting anchor bolt M8) 490 (Bolt pitch) A B 1212 (Bolt pitch) Detail A 550 92 1180 (490) (1212) Detail B Control box 1480 15.88(5/8 flare) 7, 8MYF : 25.4(1 flange) MYF : 28.6(1-1/8 flange) 142 Wiring hole 170 95 Accessory pipe (with flange) Main Optional Parts Model PAR-MAA-E PAC-SF48MA PAC-YT32PTA PAC-SE41TS-E PAC-SFRM-E PAC-SE55RA-E Description Standard remote controller M-A transmission converter Program timer Remote sensor Remote operation adapter Remote ON/OFF adapter Guaranteed Operation Range Outdoor temp. ( CDB) Cooling 50 46 0-5 - 15 24 25 Indoor temp. ( CWB) Range for continuous operation Outdoor temp. ( CWB) Heating 15 5 0-5 - -15 15 25 27 Indoor temp. ( CDB) Range for continuous operation Note: As an applicable humidity outside standard for both indoors and outdoors, we recoend use within a range of 35-80% relative humidity. However, it is a condition that there is no be dewy in surfaces of electric parts. HEAD OFFICE: MITSUBISHI DENKI BLDG., 2-2-3, MARUNOUCHI, CHIYODA-KU, TOKYO 0-83, JAPAN P 03 E-1 Prepared in Japan (KMC) New publication, effective July 03 Specifications subject to change without notice.