Planning, Manufacturing, Sales, Installation and Maintenance of Gas Measuring Systems and Gas Detection Systems for explosive and toxic gases.

Similar documents
Products and performance

Dräger X-am 7000 Multi-Gas Detection

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

Danfoss gas detection unit Type GD Heavy Duty

IGD.CO.UK

Gas Detection Sensor type GDA, GDC, GDHC, GDHF, GDH REFRIGERATION AND AIR CONDITIONING. Technical leaflet

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

SUPREMATouch. Modular Fire & Gas Detection System

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Sieger Apex. Flexibility that meets your requirements

SUPREMATouch. Modular Fire & Gas Detection System

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Dräger X-am Dräger X-am 7000: Modular, rugged and waterproof.

Gas Controller Module GC-06

Model D12-IR. Digital Gas Transmitter...

portable gas analyser

GMA200-MT. Operation Manual. Gas detection controller for mounting rail assembly

incontrol Systems Inc. Flame and Gas Detection

Dräger Polytron 7000 Fixed gas detector

GMA200-MW16. Operation Manual. Gas detection controller for wall mounting

APPLICATION DATA SHEET

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Two-Channel Gas Controller

OLC(T) 100 FIXED GAS DETECTOR

gas monitoring system

SIMRAD GD10PE IR GAS DETECTOR

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

PolyGard 2-channel Gas Controller MGC-03

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Polytector III G999 for Ex zone 0

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

Danfoss gas detection units

Dependable Solutions for Gas Detection

3M Oldham OLCT 100. Description. Fixed Gas Detector

Ammonia Detection System Codes and Design Specifications

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Dräger Polytron 8700 IR Detection of flammable gases and vapors

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

Dräger PIR 3000 Detection of flammable gases and vapours

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Gas detecting sensor Types GDA, GDC, GDHC, GDHF, GDH

PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases

Industrial Grade Gas Detection Detecting The Difference

Transmitters/Sensors. OLCT Series

Stand Alone DYNAGARD SP Operation Manual

GAS DETECTION International Gas Detectors CH4 NO

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Leak detector for refrigerant gases R22, R134a, R410A, R407C...

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

Dräger X-am 7000 Multi-Gas Detection

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

CMF, CMX & CMA series

Dräger Polytron 8000 Stationary gas detector (EC)

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Dräger Polytron Pulsar 2 Open Path Gas Detector

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

GMA200-MW4. User Manual. Gas detection controller for wall mounting

SIMRAD GD10P - IR GAS DETECTOR OPERATING MANUAL

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

ALTAIR 5X Multigas Detector Product Specification

Remote alarm indicator and test combination MK2430

Dräger Polytron 8720 IR Detection of carbon dioxide

SUPREMATouch Modular Fire & Gas Detection System

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

Engineering Guideline. pac- Carriers Type Universal

P R O D U C T D ATA S H E E T

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

portable gas analyser

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

P R O D U C T D ATA S H E E T

APPLICATION DATA SHEET

Dräger Polytron 5720 IR Toxic Gas Detection

Gas detection for your safety

Murco Core Product Guide Gas Leak Detection Solutions for all your building needs

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

Dräger PIR 7200 Toxic Gas Detection Transmitter

Xgard. Fixed detectors For flammable, toxic or oxygen gases

EC24. Operation Manual. (Type MWG 2411, MWG 2412, MWG 2413 and MWG 2414)

User Manual. PolyGard Gas Controller MGC3. Two-Channel Analog Gas Controller Serial Number _E _0907. September 2007

PolyGard Digital Gas Controller DGC-05 RS-485 Bus

Touchpoint Pro Flexible Gas Control System

APPLICATION DATA SHEET

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

Entwicklung + Fertigung + Service: Heerweg 15 D, Denkendorf Tel.: / Fax.: /

GS100M Gas Detection Controller

Dräger REGARD -1 Control System

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Transcription:

Planning, Manufacturing, Sales, Installation and Maintenance of Gas Measuring Systems and Gas Detection Systems for explosive and toxic gases Survey Sales Offices: Head Office Unna Max-Planck-Str. 15a D-59423 Unna Telefon +49 2303 33 247 0 Fax +49 2303 33 247 10 info@extox.de Export Martina Bienas Max-Planck-Strasse 15a D-59423 Unna Tel. +49 2303 33 247 14 Fax +49 2303 33 247 10 Martina.Bienas@ExTox.de Hamburg Marc Kairies Heidekamp 61d D-21244 Buchholz i.d.n. Tel. +49 4181 29 95 886 Fax +49 4181 35 03 77 Marc.Kairies@ExTox.de Leipzig Ing. Dieter Reich Dürerstr. 1 D-04571 Rötha Tel. +49 34206 68 940 Fax +4934206 77 749 Dieter.Reich@ExTox.de Düsseldorf Horst Fuchs Nordstrasse 41 D-40724 Hilden Tel. +49 2103 90 95 57 Fax +49 2103 90 95 58 Horst.Fuchs@ExTox.de München Adrian Beichl Goethestrasse 11 D-82110 Germering Tel. +49 89 899606 0 Fax +49 089 899606 16 Adrian.Beichl@ExTox.de Unna Ditmar Baer Max-Planck-Strasse 15a D-59423 Unna Tel. +49 2303 33 247 18 Fax +49 2303 33 247 10 Ditmar.Baer@ExTox.de You will find information about our company ExTox GmbH, our products and general matters concerning gas detection on our Homepage www.extox.de ExTox_Uebersicht_e_V15.doc,21/08/2007, Seite 1 von 8

Control Units In General Concentrations of flammable and toxic gases as well as of oxygen are centrally evaluated after measuring them safely with our ExTox transmitters. With the ET Series ExTox offers a multiple range of control units. The graduation of features allows a selection which completely meets your requirements of your application as far as performance and costs are concerned. The control units of the ET series could be combined with all ExTox transmitters. Further options, e. g. smoke detectors or temperature sensor, may be realised easily. The control units are available in wall mounted housing, for DIN-rail installation and for installation in 19''-Rack or control panel. The power supply can flexibly be done with 230 V AC or 24 V DC. On request we could supply you with corresponding uninterruptible power supplies for our control units. The control units in combination with ExTox transmitters comply with EN 61779 and EN 45544 for Gas Detection Systems. Furthermore they are in conformity with the European Directives 94/9/EC (ATEX), 89/336/EEC (EMC) and 73/23/EEC (LVD). ET-8D Series The control unit ET-8D is a compact and easily understandable system for up to eight transmitters, which covers also complex monitoring tasks. By means of its interfaces it is easy to integrate even in higher control systems, e. g. ProfiBus. (ET-8D) (ET-16D) 8 inputs for transmitter or smoke detectors (as option) 4 digital inputs, potential free 3 freely adjustable alarm levels per channel, latching adjustable 1 fault indication per transmitter 24 relays outputs, potential free, freely adjustable RS 232- and RS 485-Interfaces for communication with PC or PLT-Systems illuminated graphic display (240 x 64) for indication of measured values, messages and alarms LEDs for alarms, operation, channel fault, device fault and service mode service mode, horn reset and re-triggering of alarms 8 analogue outputs, potential free (only Type ET-8DA) Series ET-16D to ET-64D Systems for larger applications with 16 up to 64 transmitters are based on the ET-8D. The Control Units ET-16D and ET-24D are delivered in wall mounted housings, the Control Units ET-32D to ET-64D are mounted in cabinets. ExTox_Uebersicht_e_V15.doc,21/08/2007, Seite 2 von 8

Control Units ET-4D2 Series The System ET-4D2 is the best choice for limited measuring tasks up to 4 transmitters without abdication of the benefits of series ET-8D. (ET-4D2) 4 transmitter inputs or smoke detector (as option) 4 digital input, potential free 3 freely adjustable alarm levels per channel, latching adjustable 1 fault message per transmitter 12 relay outputs, potential free, freely adjustable RS 232- and RS 485-Interfaces for communication with PC or PLT-Systems illuminated graphic display (160 x 80) for indication of measured values, messages and alarms LEDs for alarms, operation, channel fault, device fault and maintenance service mode, horn reset and re-triggering of alarms 4 analogue outputs, potential free (only Type ET- 4DA2) ET-1D Series This small system for a single measuring point offers nearly all possibilities of the bigger systems. ET-1D is simply configurable at the device via the integrated menu control. The transmitter can even be adjusted directly at the control unit. (ET-1D) 1 transmitter input 2 digital inputs, potential free 2 freely adjustable alarm levels per channel, latching adjustable 1 fault message per transmitter 4 relay outputs, potential free, for Alarm 1 and/or 2, fault and service RS 232- and RS 485-Interface for communication with PC or PLT-Systems illuminated display (4 x 20 signs) for indication of measured values, messages and alarms LEDs for alarms, operation, channel fault, device fault and service mode service mode, horn reset integrated acoustic signaller analogue output 4-20 ma (only Type ET-1DA) ExTox_Uebersicht_e_V15.doc,21/08/2007, Seite 3 von 8

Gasmess-Systeme GmbH Störung Fault Alarm 3 Alarm 2 Alarm 1 Betrieb Power F1 Betrieb Power F2 F3 F4 F5 F6 Störung Fault ExTox Gasmess-Systeme GmbH Hildebrandstraße 5 D-44319 Dortmund Tel. +49 (0)231/589409-0 Fax. +49 (0)231/589409-10 www.extox.de e-mail: info@extox.de ESC F7 QUIT CR SHIFT Integral Measuring Concepts In General It is often necessary to monitor gas concentrations even in sealed off processes or not accessible areas. Typical applications are for example silo and tank monitoring, land fill gas measurement or bio gas facilities. Direct measurement within these processes is often impossible due to adverse application conditions. Sampling from process gas and external measurement are required instead. With the integral Measuring Concepts of the IMC Series ExTox offers efficient solutions even for those measuring tasks. This Series combines all necessary components in one compact wall mounted housing from sampling and preparation of measured gas, sensor technique and evaluation. High flexibility in adaptation to the respective application conditions held the spotlight when designing the concept. Thus only the respectively necessary components are fit with. The modular construction and the use of the approved ExTox-Transmitter and Control Units ensure a cost efficient purchase and maintenance. IMC-8D Series In the IMC-8D a control unit of the ET-8D Series will evaluate the measuring signals and release the operating commands. An extension of the control unit software integrates the control and monitoring of the components for sampling and preparation of measured gas. Due to eight available measuring channels it is possible to integrate even external transmitters without additional expenses into the system, for example for monitoring ambient air. Sensors Gas suction pump Customer specific extensions, e. g. Gas multiplexer ET-8D Connectors Gas conditioning Measured gas compact wall mounted housing (1000 mm x 600 mm x 300 mm) control of sampling and preparation of measured gas as well as evaluation of status messages by ET-8D up to 8 transmitters, out of them maximum 5 internally gas suction pump electronic flow rate monitoring dust filter Hosing: PE/PP magnetic valve for test gas application 2 fans for housing, rotary speed monitored As option: Type IMC-8DA with eight 4-20 ma-output sample point switch data logger ProfiBus -Module hydrophobic gas dehumidification gas cooler condensate trap manually/automatically flame arrestor heating for enclosure lighting of enclosure ExTox_Uebersicht_e_V15.doc,21/08/2007, Seite 4 von 8

Integral Measuring Concepts IMC-4D Series In many applications the amount of measuring gases and sample points is restricted and a complex preparation of the gas sample is not necessary. Then the IMC-4D will be an alternative to the greater IMC-8D-systems. User interface and modular construction follow the design of the greater system. compact wall mounted housing (600 mm x 600 mm x 350 mm) control of sampling and preparation of measured gas as well as evaluation of status messages by ET-4D2 up to 4 transmitters, out of them maximum 3 internally gas suction pump electronic flow rate monitoring dust filter IMC-Sens Series Hosing: PE/PP magnetic valve for test gas application 2 fans for housing, rotary speed monitored As option: Type IMC-4DA with four 4-20 ma-output condensate trap manually/automatically flame arrestor heating for enclosure In the IMC-Sens the ExTox-control unit is omitted. The measuring signal of the transmitter and provided messages are evaluated externally, for example in a superior process control system. The signals are connected to central, easily accessible clamp lines. A power supply is integrated. System AS-1 The System AS-1 combines a transmitter with a gas suction pump and flow rate monitoring. Result is a compact sampling system which is protected from environmental influences and is able to be installed close by the desired measuring point. wall mounted housing (380 mm x 300 mm x 155 mm) gas suction pump flow rate monitoring with indication by the current output of the transmitter Hosing: PVC/PE (depends on gas composition) ExTox_Uebersicht_e_V15.doc,21/08/2007, Seite 5 von 8

Biogas-Monitoring Special Type IMC-Biogas The IMC-Biogas are examples for customer specific solutions which could be designed on basis of the IMC-8D or IMC-4D according to your requirements. They are aligned to the special requirements of the biogas monitoring. Select the suitable transmitters for your measuring task out of the extensive ExTox- Programme. It covers of course all current values, such as for example Methane (CH4), Oxygen (O2), Hydrogen Sulphide (H2S) and Carbon Dioxide (CO2). High-precision Measurement of CH 4 - and CO 2 We basically focus on the measuring principle of IR-Absorption, as only this principle ensures the high requirements for a precise and repeatable measurement and the high lifetime of minimum 5 years can be achieved. Durable O 2 -Measurement The build in sensor element offers a lifetime of more than 5 years. As known from other standard O 2 sensor elements lifetime is not affected by the CO 2 -content of biogas. Persistent H 2 S-Measurement The procedure used by us is also persistent against high H 2 S-concentrations. A two-stage concept protects the electro-chemical sensor element. Up to the end value of measuring range of 3000 ppm we decrease the load of the sensor without reverting to an incorrect dilution of measured gas. In case of concentrations exceeding the end value of measuring range the sensor is flushed with air at the beginning of the next measuring cycle. Extensions to IMC-8D/IMC-4D: IMC-8D-Biogas: 8 Transmitter, max. 5 internal, IMC-4D-Biogas: 4 Transmitter,max. 3 internal software extension biogas: discontinuous measurement with adjustable intervals for measuring / flushing / waiting; indication of the latest measured value during flushing and waiting phases; control of overload protection for measurement of H 2 S flame arrestor (inlet of measured gas) IMC-8D-Biogas: condensate trap including hose pump IMC-4D-Biogas: automatic condensate trap Magnetic valve to change from measured gas to flush air (discontinuous measurement) and overload protection for measurement of H 2 S Models DA with 4-20 ma-outputs ExTox_Uebersicht_e_V15.doc,21/08/2007, Seite 6 von 8

Transmitters In General There are multiple tasks which need to be fulfilled when monitoring gases and vapours. The range covers the opportune warning before it comes to the release of flammable substances, monitoring of concentrations of toxic gases at working places as well as controlling of production processes. Due to modern sensor technique based on the measuring principles catalytic combustion, electro chemistry, semi-conductor and infrared absorption the ExTox transmitters offer excellent solutions for nearly all thinkable applications, for example: measurement of flammable gases monitoring of concentrations at working places ("MAK-Monitoring") recognizing leakages oxygen monitoring You find our wide range of measuring gas and corresponding measuring ranges in the permanently actualised transmitter survey on our Homepage www.extox.de. All transmitters could be combined. Due to their modular construction accessories and spare parts are mutually extensively interchangeable, which facilitates and enables installation, adjustment and maintenance at low cost. The measuring signal of the transmitters ExSens/Sens is a linear 4-20 ma signal output. The series Sens-I / ExSens-I Series are equipped with a RS-485 bus interface additionally. Series Sens(-I) The transmitters are suitable for use under normal industrial conditions. Series ExSens(-I) The transmitters are suitable for use in hazardous areas of Zone 1 and 2. Measuring principles: catalytic combustion (WT), IR-Absorption (IR), Electrochemical Cell (EC/KE), semiconductor (HL) 4-20 ma-interface 3-wire technique (Sens-I: 5/6-wire) linear calibration curve IP 54 (with the exception of gas inlet) Material: Aluminium/Stainless steel Wall mounting; installation under ceiling and in pipes possible Power supply: 18 to 30 V DC Max. line length of 1000 m (EC: 2000 m) when using ExTox-Cable Type EC/KE suitable for Zone 2: II 3G, EEx na IIC T6 X in addition to the Sens Series: Protection: flameproof encapsulated All transmitters suitable for Zone 1: 0158 II 2G EC-Type Tests: BVS 04 ATEX 066 X, BAM 07 ATEX 0301 X (ExSens-I BG-WT, Gases: Methane to Hexane ) Certificate of Production Monitoring acc. to Module VI of Directive 94/9/EC: BVS 07 ATEX ZQS/E238 Protection: Type WT or IR EEx d IIC T4 (-20 C Tamb 60 C) Type EC EEx d IIC T5 (-20 C Tamb 49 C) EEx d IIC T4 (-20 C Tamb 70 C) Type KE EEx d IIC T6 (-20 C Tamb 43 C) EEx d IIC T5 (-20 C Tamb 58 C) EEx d IIC T4 (-20 C Tamb 70 C) IP 65 (with the exception of gas inlet) ExTox_Uebersicht_e_V15.doc,21/08/2007, Seite 7 von 8

Monitoring of Ammonia and ph in fluid Mediums In General With development of transmitters NH3-20-IS und ph-is the company ExTox has technically improved and simplified the ammonia leakage and ph-monitoring in water, water-/glycol, sole and other fluid mediums by means of the Transmitter NH3-20-IS. The new development of an interchangeable fitting with integrated control-unit ET-F enables compact design, which safes mounting space and installation cost. The transmitters could either be used in closed circuits with a pressure range of 0.5 to 6 bar or in open, pressure-less systems, such as for example basins or channels. Installation in pipe lines is done via welded sockets (G 1 1/4 A) and interchangeable fittings, which enable the mounting and dismounting of the electrode under process conditions. An immersion fitting for pressure-less measurement is also available. Transmitter NH3-20-IS The use of the ionic-selective measuring principle offers a standard measuring range of 0 to 20 ppm. This means that leakages are recognized obviously earlier than other with conventional detecting systems. Furthermore it allows the selective ammonia detection in all fluid mediums (ph-range 4 to 13). Installation in pipe lines Installation in basins/channels 009 Control unit ET-F 009 Control unit ET-F Interchangeable fitting Immersion fitting: 500, 1000 or 1500 mm Electrode, ionic-selective Membrane Electrode, ionic-selective (ET-F) Welded socket VA Cooling water tray Pipe Line Basin Standard measuring range: 0 to 20 ppm Operation temperature: -45 to +80 C ph-range of medium: 4 to 13 Power supply: 24 V DC 4-20mA output signal, linear Display for indication of measured value 2 relay outputs (Fault, Alarm) Completely configurable by ET-F Transmitter ph-is The transmitter ph-is profits of all advantages of the combined Control Unit ET-F. The solid ph-measurement is often used for applications in refrigeration and biogas production. Measuring Range: ph 0 14 Operation Temperature: 0 C +50 C Pressure Range: up to 10 bar Power Supply: 24V DC 4-20mA output signal, linear display with indication of measured values 2 relay outputs (fault, alarm) completely configurable at the ET-F ExTox_Uebersicht_e_V15.doc,21/08/2007, Seite 8 von 8