EEDEN technical data ERHQ AA

Similar documents
EEDEN technical data ERHQ AA. Altherma. Altherma

TABLE OF CONTENTS ERHQ BAV3

TABLE OF CONTENTS ERSQ-AAY1

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EBLQ-BB6W1

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EDHQ-BB6V3

Heating. Technical Data EEDEN ERRQ-AY1

technical data air conditioning systems RZQ-B9V3B_RZQ-B8W1B Pair, Twin, Triple, Double Twin, Application, Inverter Controlled Split Sky Air

EEDEN technical data. Altherma ERHQ AA EKHBH007AC / EKHBX007AC EKSWW

technical data air conditioning systems RZQ-B Pair/Twin/Triple/Double Twin Application, Inverter Controlled Unit Split Sky Air

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units

Heating. Technical Data. Daikin Altherma low temperature split EEDEN ERLQ-CW1

EEDE06-9. technical data. Altherma ERYQ A EKHBH007A / EKHBX007A EKSWW

General Outline: Altherma

EEDEN technical data. Altherma ERHQ AD EKHBH/X008AA ERHQ AA EKHBH/X016AB EKHWS(U) EKSOL

Air Conditioning. Technical Data EEDEN AZQS-BV1

EEDEN technical data. Altherma ERHQ AD EKHBH/X008AA ERHQ AA EKHBH/X016AB EKHWS(U) EKSOL

TABLE OF CONTENTS RMXS-E8V1B

DACA-EEDEN technical data. Engineering Data. DaikinAltherma

Air Conditioning. Technical Data EEDEN RZQSG-L(3/8)V1

Air Conditioning. Technical Data. Pair, Twin, triple, double twin EEDEN RZQ-C

technical data air conditioning systems RZQ B8W1B Split Sky Air

Air Conditioning. Technical Data EEDEN RZQG-L8/7V1

Heating Nom. dba 50 (5) 50 (5) 50 (5) Cooling Nom. dba 50 (5) 50 (5) 50 (5) Anti freeze heater (optional) W Expansion vessel Volume l 6 6 6

Air Conditioning. Technical Data EEDEN RZQSG-L(8)Y1

technical data air conditioning systems RMXS-E7V3B1 Super multi plus Split Sky Air

EEDEN technical data. air conditioning systems RZQS-DV1. Split Sky Air

Air Conditioning. Technical Data. Multi model application EEDEN MXS-E

EEDEN technical data. air conditioning systems RZQS71-140C7V1B. Split Sky Air

EEDEN technical data. Altherma TM

Air Conditioning. Technical Data. High temperature hydrobox for VRV EEDEN HXHD-A8

DESIGN MANUAL Version 1.0

EEDEN technical data. air conditioning systems RZQ-DV1. Split Sky Air

Air Conditioners. Technical Data RZQG-L

Air Conditioners. Technical Data FBQ-C

Air Conditioning. Technical Data EEDEN RXS-F8

TABLE OF CONTENTS EBLQ01-016AA6V3

technical data air conditioning systems RR-B8V3B_RR-B8W1B Pair, Twin, Triple Application Split Sky Air

technical data air conditioning systems Indoor Units FBQ-C7VEB

TABLE OF CONTENTS EDLQ AA6V3

technical data air conditioning systems RZQ C7Y1B Split Sky Air

Ventilation. Technical Data. Outdoor air processing unit, ventilation and air processing EEDEN FXMQ-MF

Air Conditioners Technical Data

technical data air conditioning systems FTXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air

50A KP 70A KP 90A KP 120A KP 150A KP 210A

Air Conditioning Technical Data RZAG-MV1

Air Conditioning. Technical Data. Low temperature hydrobox for VRV EEDEN HXY-A

Air Conditioning Technical Data RZASG-MV1

Air Conditioning. Technical Data. VRV IV S-series heat pump EEDEN16-200_2 RXYSQ-TV1

technical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air

PUHZ-SHW140YHA PUHZ-SHW230YKA

Air Conditioners. Technical Data. Heating only hydrobox for VR V HXHD-A

January Engineering Data RXSQ24-60TAVJU. Heat Pump 208/230V / 60 Hz / 1 ph. Presales Manual DAIKIN NORTH AMERICA LLC

Launching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)-

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-C

Chillers. Technical Data. Air Cooled Chiller ECDEN10-403A EUWA*-KBZW1 EUWY*-KBZW1

Air Conditioning. Technical Data. VRV IV S-series compact heat pump EEDEN RXYSCQ-TV1

TABLE OF CONTENTS EKHTS-A

Digital Inverter 4 series 8 & 10HP

Air Conditioners. Technical Data FTXS-G

technical data air conditioning systems FHYCP-B7 4-way Blow Ceiling Mounted Cassette (950x950) Split Sky Air

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FXMQ-MB

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

SiENBE Service Manual. RXYSQ4-5-6PA7Y1B, PA7V1B R-410A HEAT Pump 50Hz

Air Conditioning Technical Data AZAS-MY1

technical data air conditioning systems FHYP-B Ceiling Suspended Unit Split Sky Air

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

Air Conditioning. Technical Data. Ceiling suspended unit EEDEN AHQ-C

DESIGN & TECHNICAL MANUAL

TECHNICAL DATA & SERVICE MANUAL

Air Conditioning. Technical Data. Flexi type unit EEDEN FLXS-B(9)

technical data air conditioning systems Indoor Units FCQ-C8VEB

DESIGN & TECHNICAL MANUAL

Air Conditioning. Technical Data. VRV IV heat recovery EEDEN14-200_4 REYQ-T

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTX-J3

ON/OFF. Domestic Air conditioner. Wall mounted Type Arc-Series CAUTION HSU-14HR03/R2 HSU-18HR03/R2 1. READ THIS MANUAL CAREFULLY TO

Chillers. Technical Data. EWYD-BZ 250~580 kw

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E

Air-to-Water Heat Pump (50Hz, R410A) 5BPM0-01G (Replace: 5BPM0-01F)

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

Daikin air conditioners for your home, shops, restaurants and offices

Daikin Altherma hybrid heat pump. The natural combination

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC

DESIGN & TECHNICAL MANUAL

History List. Version Date Update Information New EHS SPLIT TDB Released. (Modify the Spec Note)

MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service manual MSZ-EF VE Series (OBH589)

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

TECHNICAL DATA & SERVICE MANUAL

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-B

condenciat cl Condensing units Outdoor condensing unit Variable speed propeller fan Use Description for direct expansion applications

Air Conditioning Technical Data FFA-A > FFA25A2VEB > FFA35A2VEB > FFA50A2VEB > FFA60A2VEB

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

R4H4. Product Specifications

Remote control infrared ARC433B76 ARC433A8 ARC433B69

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER OUTDOOR UNIT: AE22AC/ACL/AH AE28AC/ACL/AH AE38AC/ACL/AH AE42AC/ACL/AH

technical data air conditioning systems FH(Y)B-FK7 Concealed Ceiling Unit Split Sky Air

Transcription:

EEDEN08-70 technical data Altherma

Outdoor units R-410A Altherma Outdoor units 34 1 Features 1 O u t d o o r u n i A l t h e r m a E R H Q 0 1 1-0 1 6 A A R - 4 1 0 A Cost effective alternative to a fossil fuel boiler Low energy bills and low CO emissions Easy to install Total solution for year round comfort

Specifications Outdoor units R-410A -1 NOMINAL CAPACITY AND NOMINAL INPUT For combination indoor units + outdoor units Condition 1 Nominal Capacity For combination indoor units + outdoor units ERHQ011AA ERHQ014AA ERHQ016AA ERHQ011AA ERHQ014AA ERHQ016AA Indoor Units EKHBH016AB EKHBH016AB EKHBH016AB EKHBX016AB EKHBX016AB EKHBX016AB Heating capacity Cooling capacity Nominal kw 11. 14.0 16.0 11. 14.0 16.0 Nominal kw 13.9 17.3 17.8 Heating PI Nominal kw.46 3.17 3.83.46 3.17 3.83 Cooling PI Nominal kw 3.79 5.78 6.77 COP Nominal 4.55 4.4 4.18 4.55 4.4 4.18 EER Nominal 3.67.99.63 Heating capacity Cooling capacity Nominal kw 10.3 13.1 15. 10.3 13.1 15. Nominal kw 10.0 1.5 13.1 Heating PI Nominal kw 3.06 3.88 4.66 3.06 3.88 4.66 Cooling PI Nominal kw 3.60 5.9 5.95 COP Nominal 3.37 3.38 3.6 3.37 3.38 3.6 EER Nominal.78.36.0 Notes Condition 1: cooling Ta 35 C - LWE 18 C - heating Ta DB/WB 7 C/6 C - LWC 35 C ( DT = 5 C ) Condition : cooling Ta 35 C - LWE 7 C ( DT = 5 C ) - heating Ta DB/WB 7 C/6 C - LWC 45 C ( DT = 5 C ) - TECHNICAL SPECIFICATIONS ERHQ011AA ERHQ014AA ERHQ016AA ERHQ011AA ERHQ014AA ERHQ016AA Casing Colour Ivory white Material Painted galvanised steel plate Dimensions Unit Height mm 1170 1170 1170 1170 1170 1170 Width mm 900 900 900 900 900 900 Depth mm 30 30 30 30 30 30 Packing Height mm 1349 1349 1349 1349 1349 1349 Width mm 980 980 980 980 980 980 Depth mm 40 40 40 40 40 40 Weight Unit kg 103 103 103 103 103 103 Packed Unit kg 114 114 114 114 114 114 Packing Material EPS Heat Exchanger Carton Wood PP (Straps) Weight kg 11 11 11 11 11 11 Dimensions Length mm 857 857 857 857 857 857 Tube type Nr of Rows Fin Pitch mm 1.4 1.4 1.4 1.4 1.4 1.4 Nr of Passes 6 6 6 6 6 6 Face Area m² 0.98 0.98 0.98 0.98 0.98 0.98 Nr of Stages 5 5 5 5 5 5 Hi-XSS(8) Fin Type WF fin Treatment Anti-corrosion treatment (PE) Fan Type Propeller Air Flow Rate (nominal at 30V) Quantity Heating High m³/min 90 90 90 90 90 90 Cooling High m³/min 96 100 97 Altherma Outdoor units 35

Specifications Outdoor units R-410A - TECHNICAL SPECIFICATIONS Fan Discharge direction Horizontal Motor Motor Quantity Speed (nominal) Model Brushless DC motor Output W 70 70 70 70 70 70 Steps 8 8 8 8 8 8 Heating rpm 760 760 760 760 760 760 Cooling rpm 800 850 830 Fan Motor Output W 70 70 70 70 70 70 Drive Direct drive Compressor Quantity 1 1 1 1 1 1 Operation Range Level (nominal) Level (Night quiet) Motor Model JT100G-VD Type Motor Output Starting Method Crankcase Heater Hermetically sealed scroll compressor W 00 00 00 00 00 00 Inverter driven W 33 33 33 33 33 33 Heating Min CWB -0-0 -0-0 -0-0 Max CWB 35 35 35 35 35 35 Cooling Min CDB 10 10 10 Max CDB 46 46 46 Sanitary water Min CDB -0-0 -0-0 -0-0 Heating Cooling Heating Cooling Max CDB 43 43 43 43 43 43 Power Pressure Power Pressure Pressure Pressure dba 64 64 66 dba 49 51 53 49 51 53 dba 64 66 69 dba 50 5 54 dba 4 4 43 4 4 43 dba 45 45 46 Refrigerant Type R-410A Charge kg 3.7 3.7 3.7 3.7 3.7 3.7 Control ERHQ011AA ERHQ014AA ERHQ016AA ERHQ011AA ERHQ014AA ERHQ016AA Expansion valve (electronic type) Nr of Circuits 1 1 1 1 1 1 Refrigerant Oil Type Daphne FVC68D Charged Volume l 1.0 1.0 1.0 1.0 1.0 1.0 36 Altherma Outdoor units

Specifications Outdoor units R-410A - TECHNICAL SPECIFICATIONS Piping connections Defrost Method Defrost Control Liquid (OD) Quantity 1 1 1 1 1 1 Type Diameter (OD) Flare connection mm 9,5 Gas Quantity 1 1 1 1 1 1 Type Diameter (OD) Flare connection mm 15,9 Drain Quantity 3 3 3 3 3 3 Type Diameter (OD) mm 6 6 6 6 6 6 Piping Length Minimum m 5 5 5 5 5 5 Maximum m 75 75 75 75 75 75 Equivalent m 95 95 95 95 95 95 Chargeless m 30 30 30 30 30 30 Additional Refrigerant Charge kg/m See installation manual outdoor unit 4PW37976-1B Installation height difference Capacity Control Method Safety Devices Standard Accessories Notes Heat Insulation Item Maximum m 30 30 30 30 30 30 Hole Both liquid and gas pipes Pressure equalising Sensor for outdoor heat exchanger temperature Inverter controlled Fan motor thermal protector Fuse High pressure switch Tie-wraps Quantity Item ERHQ011AA ERHQ014AA ERHQ016AA ERHQ011AA ERHQ014AA ERHQ016AA Installation manual Quantity 1 1 1 1 1 1 The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Down to 3m with recharging of the outdoor unit. Refer to the installation manual of the outdoor unit. -3 ELECTRICAL SPECIFICATIONS ERHQ011AA ERHQ014AA ERHQ016AA ERHQ011AA ERHQ014AA ERHQ016AA Power Supply Name V3 Current Wiring connections Power Supply Intake Phase 1~ Frequency Hz 50 50 50 50 50 50 Voltage V 30 30 30 30 30 30 Voltage range Minimum V -10% Maximum running Current Maximum V +10% Cooling A.8 7.4 31.9 Recomended fuses A 3 3 3 3 3 3 For Power Supply For connection with indoor Remark Remark See installation manual outdoor unit 4PW37976-1B See installation manual outdoor unit 4PW37976-1B Outdoor unit only Altherma Outdoor units 37

3 38 3TW5775-1 Outdoor units R-410A Conditions 1. Cooling capacity Capacity is according to Eurovent rating standard 6/C/003-006 and valid for chilled water range D1= 3-8 C. Heating capacity Capacity is according to Eurovent rating standard 6/C/003-006 and valid for chilled water range D1= 3-8 C 3. Power input Power input is total input of indoor and outdoor unit, except the circulation pump; according to Eurovent rating standard 6/C/003-006 Pump power input to be added=90w (according EN14511) Capacity tables Altherma Outdoor units Symbols CC Cooling capacity at maximum operating frequency, measured acc. Eurovent 6/C/003-006 [kw] HC Heating capacity at maximum operating frequency, measured acc. Eurovent 6/C/003-006 [kw] PI Power input [kw], measured acc. Eurovent 6/C/003-006 [kw] LWE Leaving Water Evaporator temperature [ C] LWC Leaving Water Condensor temperature [ C] Tamb Ambient temperature [ C] RH=85% 3 MAXIMUM CAPACITY - INTEGRATED VALUE Heating capacity tables MAXIMUM CAPACITY - PEAK VALUES 3-1

Altherma Outdoor units 39 MAXIMUM CAPACITY Symbols CC Cooling capacity at maximum operating frequency, measured acc. Eurovent 6/C/003-006 [kw] HC Heating capacity at maximum operating frequency, measured acc. Eurovent 6/C/003-006 [kw] PI Power input [kw], measured acc. Eurovent 6/C/003-006 [kw] LWE Leaving Water Evaporator temperature [ C] LWC Leaving Water Condensor temperature [ C] Tamb Ambient temperature [ C] RH=85% Conditions 1. Cooling capacity Capacity is according to Eurovent rating standard 6/C/003-006 and valid for chilled water range D1= 3-8 C. Heating capacity Capacity is according to Eurovent rating standard 6/C/003-006 and valid for chilled water range D1= 3-8 C 3. Power input Power input is total input of indoor and outdoor unit, except the circulation pump; according to Eurovent rating standard 6/C/003-006 Pump power input to be added=90w (according EN14511) 3TW5775-1 3 3 - Cooling capacity tables 3 Capacity tables Outdoor units R-410A

4 40 Altherma Outdoor units Hole for anchor bolt 4-M1 1 Gas pipe connection 15.9 flare Liquid pipe connection 9.5 flare 3 Service port (in the unit) 4 Grounding terminal M5 (in switch box) 5 Refrigerant piping intake 6 Power supply wiring intake (knock out hole 34) 7 control wiring intake (knock out hole 7) 8 Drain outlet 4-1 Dimensional drawing 4 Dimensional drawing & centre of gravity Outdoor units R-410A 3TW57764-1

Altherma Outdoor units 41 EKHB 016 Indoor Unit Field Piping ø9.5 C 10T-0 Field Piping ø15.9 C 10T-0 Stop Valve (With Service Port 5/16 Flare) Accumulator Electronic expansion valve Filter Filter Heat exchanger 4-Way-Valve High Pressure Low Pressure Switch Sensor Compressor Outdoor Unit Check Valve Flare Conn. Screw Conn. Flange Conn. Pinched Pipe Spinned Pipe Heating Cooling Service Port 5/16 3TW57765-1 5 5 Piping diagram Outdoor units R-410A

6 data 6-1 pressure spectrum Outdoor units R-410A 6 ERHQ011AAV3 ERHQ014AAV3 ERHQ016AAV3 Octave band center frequency (Hz) Octave band center frequency (Hz) Octave band center frequency (Hz) 3TW57767-A NOTES 1 Data is valid at free field condition (measured in a semi-anachoic room). dba = A-Weighted sound pressure level. (A-scale according to IEC) 3 Reference acoustic pressure 0dB = 0µPa. 4 If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections. Measuring location (Discharge side) ERHQ011AAV3 ERHQ014AAV3 ERHQ016AAV3 Octave band center frequency (Hz) Octave band center frequency (Hz) Octave band center frequency (Hz) 3TW57767-1A NOTES 1 Data is valid at free field condition (measured in a semi-anachoic room). dba = A-Weighted sound pressure level. (A-scale according to IEC) 3 Reference acoustic pressure 0dB = 0µPa. 4 If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections. Measuring location (Discharge side) 4 Altherma Outdoor units

6 data 6-1 pressure spectrum Outdoor units R-410A ERHQ011AAV3 ERHQ014AAV3 ERHQ016AAV3 6 Octave band center frequency (Hz) Octave band center frequency (Hz) Octave band center frequency (Hz) 3TW57767-4 NOTES 1 Data is valid at free field condition (measured in a semi-anachoic room). dba = A-Weighted sound pressure level. (A-scale according to IEC) 3 Reference acoustic pressure 0dB = 0µPa. 4 If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections. Measuring location (Discharge side) ERHQ011AAV3 ERHQ014AAV3 ERHQ016AAV3 Octave band center frequency (Hz) Octave band center frequency (Hz) Octave band center frequency (Hz) 3TW57767-3 NOTES 1 Data is valid at free field condition (measured in a semi-anachoic room). dba = A-Weighted sound pressure level. (A-scale according to IEC) 3 Reference acoustic pressure 0dB = 0µPa. 4 If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections. Measuring location (Discharge side) Altherma Outdoor units 43