False Alarm Management

Similar documents
False Alarm Management

Different types of Fire Alarm System

Silent Knight Software Suite Intelliknight Training

one Operating instructions SenTRI ONE panel-based Fire detection and alarm system

Laptop / PC Programming Manual

ZERIO PLUS EDA-Z5008, Z5020 & Z5100

Digiplex LED Keypads User s Manual

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

LOG BOOK & CERTIFICATES

CSP-204 CSP-208 CSP-104 CSP-108

The EN54 Part 2, 4 and 13 Fire System

Intelligent Security & Fire Ltd

HS-5100, HS-5200, HS-5400 ANALOGUE ADDRESSABLE CONTROL PANELS. User Manual. Approved Document UI-ELAN-02 Revision 03

IDS816 User Manual H Issued January 2009

user manual Document No , Revision 03 November 2015

Watchguard WGAP864 User Manual

Operating instructions SENTRI4 Control panel based Fire detection and alarm system

NX-148 LCD CODE PAD TABLE OF CONTENTS

XFP NETWORKABLE ANALOGUE ADDRESSABLE FIRE ALARM CONTROL PANEL. user manual and log book. approved document no. DFU Rev 1

Contents. Glossary

PREMIER M PLUS USER MANUAL, MAINTENANCE GUIDE & LOG BOOK 8-24 ZONE CONVENTIONAL FIRE ALARM PANEL LOG BOOK & CERTIFICATES

ZM2 OPERATING AND MAINTENANCE INSTRUCTIONS

[ [ ADMIN PANEL USER GUIDE

Conventional Fire System. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI User Manual

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

user manual and log book XFP NETWORKABLE ANALOGUE ADDRESSABLE FIRE ALARM CONTROL PANEL

Operating instructions Vigilon panel and Network node Fire detection and alarm system

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

TV2 Room Pressure Monitor Quick Start Guide

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

ZP2 Series Operation Manual

PARAGON PLUS USER INSTRUCTIONS USER INSTRUCTIONS J?>5 J?>5 J?>5 J?>5 J?>5 J?>5 B??=

3.1 Introduction. 3.1 Introduction

Algo-Tec 6500/6600 INTERACTIVE ADDRESSABLE FIRE CONTROL SYSTEM

Spa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert)

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad...

WeatherLink for Alarm Output Addendum

Monitoring Operator Guide. Access Control Manager Software Version

IDS S E C U R I T Y IDS816. User Manual. MANUAL NO A ISSUED November 2004 VERSION 1.00

ABORT Light flashes during an abort delay time; is on during or after an alarm report to the central station. EMERGENCY ACTIVATION KEYS

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Destiny Destiny Owners Manual

Fire detection and alarm system Operating instructions

Ovation Alarm Management System

Intelligent Single Loop Fire Alarm Control Panel

Control/Communicator Installation Manual

Protégé Eclipse LED Keypad User Manual PRT-KLES

Lyric Gateway. User Reference Guide. Ref: LCP300-L/LCP300-LC /16 Rev A

Xtralis VESDA LCD Programmer Quick Reference Guide

Control Panel User Guide

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections.

A GUIDE TO FIRE DETECTION AND ALARM SYSTEMS

Unwanted Fire Alarms. Marty Ahrens National Fire Protection Association 1 Batterymarch Park Quincy, MA (617)

Wireless Security System

Intelligent Security & Fire Ltd

TV2 Clean Room Monitor

IDS S E C U R I T Y IDS816. User Manual MANUAL NO C ISSUED APRIL 2005 VERSION 2.00

HARDWIRED CONTROL PANELS

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

Ammonia Leak Detector Manual

ViewMatrix. Software for Online Monitoring & Control of Matrix2000 Conventional Fire Alarm Panels. Version: 2.0 Revision: 0.1

Logbook. Precept EN Fire Detection/Alarm Panel. & Precept EN Repeater

Document No Issue 4 user manual

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

DCS2000 DEMENTIA CARE SYSTEM USER GUIDE. For Software Version 1.2 1

Alarms Updated 03/26/2018

Ceiling PIR HS presence detector. Product Guide. Overview. Features

Digiplex LED Keypads. User s Manual

NetworX NX-8V2. LED Keypad User Manual

Control Panel User Guide (TO BE RETAINED BY THE USER)

Standard for the Installation of Carbon Monoxide (CO) Detection and Warning Equipment

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual

DXL ALA Settings Guide

IDS800 USER MANUAL. Summary of Operation. + [ ] 2 IDS800 USER MANUAL NO K ISSUED APR 2003 VER 1.44

KFP-CF Series Operation Manual

AFP-300/400 OPERATORS MANUAL INTELLIGENT FIRE DETECTION AND ALARM SYSTEM SOFTWARE VERSION 2.2 REVISION AUS 3

IDS S E C U R I T Y IDS816. User Manual MANUAL NO B ISSUED DEC 2004 VERSION 2.00

DESTINY OWNER S MANUAL

Security Management System - Configuring Video Analytics

HILLS Series LED Code Pad User Manual

RANGEOVERVIEW Integrated Emergency Lighting & Fire Detection System

Operator s Manual Part: InfoAlarm Product: 4100U, 4100ES Rev. B

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

Monitor Alarms and Events

Intruder alarm system Operating Instructions

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure.

Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA series Protocols)

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

The EN54 Part 2 & 4 Fire System

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

Policy for safe working on Fire Alarm Systems at Loughborough University and Loughborough University in London

ZSC100 Gas Detection and Alarm System Controller

Installation, Operating and Maintenance Manual

Beacon 800 Gas Monitor Operator s Manual

Transcription:

False Alarm Management This document is intended only for fire system professionals who are already experienced in the selection and positioning of fire detectors. Whenever you apply any False Alarm Management technique, always take the time to think through the system design to ensure that genuine fires will still give the required response. AlarmCalm is Advanced s False Alarm Management (FAM) solution. It includes, hardware, software and intelligent loop devices for alarm acknowledgement. When used with an Advanced MxPro 5 or Axis EN FACP, the FAM option in Advanced s DynamixTools config software gives users unprecedented control of false alarm strategy, implementation and management. AlarmCalm allows users to manipulate both Verification Times and Investigation Delays to Outputs. Both are handled in the same simple but powerful fashion and both play an important role in total FAM. This document covers the specific Verification options. Investigation Delays to Outputs are not included but are managed in the same fashion. 680-513 REV 01

Alarm Verification (Confirmation) Alarm Verification can be configured by selecting the False Alarm Management icon from the MxPro configuration software.. Please ensure your panels are running 051-02, or higher, firmware before using this feature. Background When Alarm Verification is selected the panel will carry out additional checks before determining that an alarm signal from a detector is a real fire. What happens during the verification process can be tailored to the particular requirements of each building. There are two fundamental methods of fire verification which to a large extent are dictated by the ability of the occupant to take action to prevent the situation turning into a full unwanted fire alarm. Verification Method Type A (Not Displayed) With this method the panel allows any qualifying detector to go briefly into alarm for up to 60s without it causing a fire. The panel display will show normal providing the detector clears within this period.

Verification Method Type B (Displayed) This method offers greater flexibility and can also allow individual detectors to go into alarm for longer periods before determining that a fire has occurred. Throughout the verification, the panel and any associated repeater panels will provide information on the location of the alarm. It is also easy to program the panel to give audible and visual warnings that are targeted specifically at occupants in the vicinity of the potential alarm (e.g. in the room in which the toast is burning). Options also allow confirmation of the fire by detector mode change, or by a second detector. Building Areas AlarmCalm allows users to configure up to 200 Building Areas per FACP. These are virtual areas, independent of fire zones that can have individual or bacth FAM setting applied. They allow total false alarm configuration to be set for any site or system.

Verification by Building Area The Configuration program first shows a default setting that will apply to all areas of the building covered by the selected panel. It is often necessary to have different verification strategies for different areas of the building. Each panel supports up to 200 building areas. Areas can be added from the Add Building Area icon The quickest way to specify requirements is to first to enter the parameters that apply to most of the areas covered by the panel, and then add only the exceptional areas. E.g. A multi-occupant building with 50 apartments, all with identical verification requirements. The building also has 4 escape corridors Verification is not allowed in the escape corridors. Let s say the escape corridors are in areas 10, 15, 20 & 27. There is no need to define each individual apartment. Add only the escape areas, with all 50 apartments being specified in the Other Areas column. E.g.

Building Area Concept Why area, why not just use zones? As default the Building area is indeed just the same as the detection zone. i.e. zone 1 = Building Area 1 zone 2 = Building Area 2 etc. There is no need to change this relationship if this is sufficient to specify the false alarm management requirements. Leaving the Building Area for a device the same as the zone number is generally the quickest and easiest way. If more flexibility is required the definition of building area can be adjusted using the Extended Building Area Settings option. Deselecting the Use zone number for point building area allows detection points to be assigned to any required area. This is useful if the area in which verification is required does not align with a zone boundary e.g. where several rooms, each requiring independent verification, are within the same detection zone. How do I assign devices to a Building Area? If the Extended Building Area Settings are not used, the Building Area for a device will automatically be set to the zone number. If Extended Building Area Settings are used, the Building Area can be assigned from the Point Details view. e.g.

How many detectors can be in a single Building Area? This is not restricted. An area can contain just a single detector, or at the other extreme every device on a panel could be assigned to a single Building Area. Can two or more areas be in verification at the same time? Yes. Each area can be in a state of alarm verification, independent of what is happening in other areas. E.g. hotel with each room assigned to different areas. Multiple rooms can be in verification for different reasons - steam from shower in one room while excessive use of aerosol in another room. Can I limit the number of areas simultaneously in verification? Yes. In some situations it may well be desirable to enter a fire condition if multiple areas are in verification at the same time. The Maximum Areas in Verification allows a limit to be placed on this. Setting Maximum Areas in Verification to 1 will mean that a fire will be deemed to occur if more than a single Building Area is in alarm at any instant in time. Setting Maximum Areas in Verification to 20 will allow 20 different Building Areas to be simultaneously in verification. If an alarm occurs in another location while the others are still in verification, then the panel will deem a fire to have occurred. All areas will then enter the fire condition.

Day And Night Settings In some situations the verification requirements may differ according to time of day, or an area being occupied / unoccupied. The Time Clock option allows any one of the 10 programmable time clocks to be used for this purpose. Each Building Area then has independent Day and Night settings :- In addition to these settings, certain types of detector also have the ability to change modes. For these detectors the Mode (When Verifying) can also be set differently during the daytime and night time on the Loop/Show Details Point Details screen. e.g.

Adjustable Parameters for each Building Area Operation Allow Verification Allow Acknowledge Setting Yes The selected Verification Inputs will enter verification before a fire is confirmed N o - All detection devices in the area go immediately into fire alarm. Yes - Alarms requiring extended time to clear or investigate can be acknowledged by occupants in the area, or from the control panel. No Alarm acknowledgment facility not used in this area. Verified by 2 nd Device Verified by Mode Change Yes A fire alarm is confirmed immediately when a 2 nd detector in the area signals an alarm. No More than one device can signal an alarm while the panel is still within the verification time. Yes Multimode detectors have the option to change their mode to the specified Verification mode during the verification process. If the alarm signal is also received from the detector once it has changed mode, a fire is immediately confirmed. Verification Inputs The types of detector that are allowed to be used for verification can be readily defined for each area. These can be set for Heat Detectors Smoke Detectors Multi Sensors Other inputs. The options available are :- All All detectors of the specified type will be verified. None of the specified type of device will be verified Per Point Detection points are individually set to verify or not verify. Verification Outputs The types of output that can automatically activate during verification are : Sounders Beacons Relays The options available for each type of output are :- All All of the specified type of outputs in the area will activate during verification. None of the specified type of outputs will activate. Per Point Only individually selected outputs of the specified type will activate.

Verification Times With verification Type B there are a number of adjustable timing parameters. In the following examples we will consider the effects of these times on a smoke detector signal, however the principles are also the same for other types of detector. The Verification Time starts from the instant the smoke in the detector increases above the Alarm Threshold. The panel will turn on any Verification Outputs (i.e. outputs in the same building area as the smoke detector) while verifying the alarm. In the example in Figure 1, by the end of the verification time, the smoke has cleared from the detector, avoiding a full fire alarm condition. The panel will hold the Building Area in the verification state until the Verification Hold Time has elapsed. If the smoke increases and remains above the Alarm Threshold prior to the Verification Hold Time elapsing, the panel will go into full fire alarm condition. Figure 1. Smoke cleared, no alarm. In figure 2, smoke is still above the alarm threshold at the end of the verification time, so the panel goes to full fire alarm condition. Figure 2. Smoke not cleared - Alarm

The AlarmCalm Button & Alarm Acknowledgement Facility (AAF) Building occupants are often able to recognize and acknowledge potential unwanted alarms, such as from burnt toast. The Alarm Acknowledgement Facility supports various methods of AAF input signals that in turn extend the time to investigate and rectify the situation before a full fire alarm condition is raised. The occupier must press an AAF input, like the AlarmCalm Button (loop device) before the Verification Time has elapsed, as in Figure 3 below, allowing an additional time 2 nd Stage Time for the smoke to clear. Figure 3. Smoke cleared after acknowledgement. No alarm Once the smoke clears the panel will automatically cancel the verification and return to normal (as long as the Verification Hold Time has also elapsed). The 2 nd Stage Time begins when the AAF button is pressed. If the smoke is still present at the end of the 2 nd Stage Time, a full fire condition will be raised as in figure 4. Figure 4. Smoke does not clear after acknowledgement fire alarm.

AlarmCalm Buttons Alarm Acknowledgement from Loop Inputs AlarmCalm Buttons are loop powered devices and can be placed at any required address on the loop. Placing an AlarmCalm pushbutton in each Building Area allows the occupants in that area to acknowledge a potential false alarm without effecting occupants in other areas. From the Device Selector, check the default Zone number corresponds with the required Building Area, and then click on the AlarmCalm Button icon. Point Details then show how the device is being used. In the example below the AlarmCalm Button acknowledges detectors and silences verification outputs in zone 73. Alternatively, if Building Area is being kept separate to the zone number, the example below acknowledges detectors and silences the verification outputs in Building Area 153.

Global Acknowledgement It possible to configure panel inputs with an Alarm Acknowledgement Facility (AAF) regardless of the Building Area in verification. To do this, define the Input Action as Acknowledge. e.g. Used For gives the following AAF Options :- AAF Only AAF (with Silence) Verification alarm in any Building Area is acknowledged without any effect on the verification outputs. Verification alarm in any Building Area is acknowledged and verification outputs are turned off. Delaying Outputs / AAF Dual function button. Acknowledges both Investigation Delay- To- Outputs (Post Fire Alarm investigation) and verification alarms.

Verification and Networks Each panel is configured with it s own verification strategy. This allows most verification settings to be changed without undue concern over how this may effect other panels on the network. Verification information does pass over the network. As default, all nodes will be aware of verification alarms occurring at other nodes on the network. You may wish to control (limit) the effects of this in some situations. Network Displays All displays on the network will, for type B verification, identify the zone and location text of any detector in verification alarm. If you do not wish to display this information at certain nodes, un-tick the Network Pre Alarm zone status qualifier for those zones. e.g. to suppress verification alarms occurring in zones 1..9 elsewhere on the network :- Maximum Areas in Verification As default the Maximum Areas in Verification includes both fires occurring on the panel being configured and those occurring on other panels on the network. If verification alarms occurring at certain other panels on the network should not be included, then they can be excluded according to the sector assigned to each networked panel. e.g. to exclude the verification alarms from sector 2 :-

Alarm Acknowledgement over Network Global acknowledgement of verification alarms is supported over the network. If acknowledgements from certain other panels on the network should not be accepted, then they can be excluded according to the sector assigned to each network panel. To do this, un-tick the Investigation box for unwanted sectors as required. e.g. to ignore acknowledgements from Sector 3 :- Duplication of Building Area numbers in a network. Building Areas should generally be unique to each panel on the network. This is automatically enforced when the Building Area is left the same as the zone number. Frequently Asked Questions Q) Once configured and in use on site, how do I know if verification has been used? A) All verification alarms from detectors will be recorded in the panel event log. Q) I want to configure a multi sensor to change into a heat only mode while verifying, but I can t get the Point Details to show it s Mode (when verifying). A) The configuration program will only display this information if it is relevant, so it is likely that the device has not been set to verify alarms for that area of the building, or for that category of device. For the area in question, ensure that the following have been set : a) Allow Verification - YES b) Verified by Mode Change - YES c) Multi Sensors - ALL (or per point)