Loops and Power Lines

Similar documents
A. Connected to the equipment ground B. Bonded to the box C. Connected to nearest water pipe D. Connected to a ground rod

3510 East Atlanta Avenue, Phoenix, AZ USA

Operating Instructions

Addressable NAC Output Module D327A

teambrite Supply Mytee Escape ETM-LX-115 Electric Truckmount, 115V with 165 ft hose set and carpet cleaning wand Includes the following items:

MD12-2 Vehicle Loop Detector

Sidel Combi-Combi Therm & CO2 Counter Installation Guide

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Building Division 201 SE 3 rd STREET (Second Floor) OCALA, FL Phone: (352) BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS

CHAPTER 20 SERVICE EQUIPMENT

MD12-1 Vehicle Loop Detector

Soltron Sea Shell XXS-35

Multi-Core Fire Resistant Cable

F I R E G A R D D C EXTENDED PERFORMANCE RELEASE DEVICE SAFE A N D SECURE

MBCE-110/230FR Flame Sensor Module

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

GPF Dimming Panels. GRAFIK Systems SPECIFICATION SUBMITTAL

Ozone Generator Systems

Rocky Mountain Chapter IAEI Annual Meeting Northglenn, CO March 18-19, 2004

MBCE-110/230UV Flame Sensor Module

STERI-VAC CENTRAL SUCTION SYSTEM

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

GCW SERIES Gas Cylinder Warmers

Operating Instructions

Liquid Helium Level Instruments

VIKING RANGE CORPORATION, P.O. DRAWER 956, GREENWOOD,MS USA

CRYOGENIC EXPERTS, INC. World Wide Web Toll Free FOR CEXI Phone (805) Facsimile (805)

CHAPTER SIX Automatic Gates

2009 ELECTRICAL CODE REQUIREMENTS

ASSEMBLY AND OPERATING INSTRUCTIONS. Read these instructions carefully before using this device.

Installation and Operation Manual Low Power (LP) DC Power System

Operating Instructions

3226 Trunk Port FXO Doorphone

Industrial Contractors Supplies

Public Safety DAS Annunciator Panel

OWNER S MANUAL MODEL TG 9000ES Industrial Generator

Subpanels. Bring Big Amps to Distant Spaces. A subpanel is a secondary breaker box BY CLIFFORD A. POPEJOY

ELECTRICAL SAFETY INSPECTION REPORT

Data Bulletin. Determining the Cause of AFCI Tripping Class 760

PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Rev D.01

ENGINEERING CONTROLS FOR SILICA DUST (DUST COLLECTION SYSTEM)

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Apr06 Rev A

CONTENTS CONSIDERATIONS. General Plumbing Component Connection ILLUSTRATION. Control System CONFIGURATION. Voltage Verification CONNECTION

IDP-Zone-6 Six Zone Interface Module

EZ CLEAN IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. External Aquarium Filter

SECTION ELECTRICAL IDENTIFICATION

Cookson Company 1901 South Litchfield Road Goodyear, AZ Phone:

Michigan Chapter IAEI Annual Meeting Ann Arbor, Michigan Code Panel Questions December 5 th and 6 th, 2013

Securitron Magnalock Corporation S. 51 st St., Ste. 102 Phoenix, AZ Phone: (800) MAGLOCK

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

MMF Six Zone Interface Module

Incident Summary (Reference # )

DAP III Zone Master User s Guide

Arc-Fault Circuit Interrupters (AFCIs) Frequently Asked Questions

FlowMark Model Mark-II-SC Installation Operation Manual. EPA Est.#: FL-1

Company, Inc. Location

Incident Summary (Reference # )

MBCE-110/230FR Flame Sensor Module

Models Product Information. Important Safety Instructions REV

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

For more information, please visit or call toll free at

DOOR MONITORING/DURESS SYSTEM

INSTALLATION AND OPERATING INSTRUCTIONS. For Reliance Controls Emergency Power Transfer Switch Kit Model Number 30216BRK

08/17/2011 Rev. 4 PULL STATION EXHAUST HOOD 10 TO 20 FEET FROM HOOD LOCATE ONE NEAR EVERY POINT OF EGRESS FROM HOOD

NEC 2017 Changes and Their Effect Upon the ICT Industry

IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER

Installation Instructions

ELSEMA MD2010. Application Controls automatic doors or gates when a vehicle is present. Description

Hi-lume 3D Overview. Fluorescent Dimming Ballasts Hi-lume 3D Architectural Dimming

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES

F1202 TRACE HEATING. Road & Ramp

RAIN COLLECTOR HEATER

HEAT PUMP INSTALLATION MANUAL

WARNING USER S MANUAL. Model iq 2000 Series Dust Collector with manual shaker

SECTION (16075) - IDENTIFICATION FOR ELECTRICAL SYSTEMS

TPI Corporation P.O. BOX 4973 JOHNSON CITY, TN

TECHNOLOGY CORP. Taking a bite out of energy costs. Instruction Manual for the ORKA Remote Thermostat/Humidity Controller.

SIMPLEX WEATHERPROOF CONTROL PANELS

Installation Instructions

Installation Instructions

SLATE. Sub-Base Module INSTALLATION INSTRUCTIONS R8001S9001

INSTALLATION INSTRUCTIONS FOR ENTRANCE CONTROL SYSTEM MODEL GL-RO-3

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

Electricity Unit Notes. Agriculture Mechanics I

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

Data Sheet. Self regulating heating tapes. RS stock numbers

A HOMEOWNERS HANDBOOK

America s Best Home Products, L.C. 855-GF14FAN. CoolMyGarage.com

PZ2 Series Manual. PROZONE INTERNATIONAL, Inc. Ozone Water Purification Systems. INSTALLATION GUIDE and OPERATION MANUAL. Prozone PZ2 Series

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Operating Instructions

Afci TR Duplex 20A 125V La. Features amperage rating 20. Dimensions and Weight Width 3.3. Long Description

HOME LOAD MANAGER INSTALLATION MANUAL Hardware Revision 1.4 & Higher

TOKISTAR LIGHTING INSTRUCTION MANUAL. Advantage Series. Xenon Lamp. Socket. Side View. 2.4 O.C. (60 mm) 3 O.C. (75 mm) 4 O.C. (100 mm) 6 O.C.

Ozone Generator Systems

FreezGard. Self-regulating crankcase heater. Product Overview

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

Transcription:

BD Loops 8161 Monroe Ave Stanton, CA 90680 P: 714-723-0946 F: 714-890-1603 BD Loops Loops and Power Lines.......... Observations of a loop s performance when laid directly over power lines.

Loops and Power Lines Observations of a loop s performance when laid directly over power lines. Purpose: Observe and record the affect power lines have on loop performance. Hypothesis: When the loop is connected to a fully featured detector module there will be no visible/recordable effect. Loop may experience interference when connected to a more basic detector module. Materials: BD Loops preformed saw-cut loop made with 16AWG wire. Both loop and lead-in section are made with untwisted jacketed wire. o 1 - SC 24-20 (4x8 (24ft) loop with a 20ft lead-in) 1 EDI Detector Model#LMA-1800 (detector has a deflector meter to show how much an object changes the inductance of a loop) 1-EDI Oracle Detector Model Detector has 20 levels of sensitivity. 1 Diablo DSP-11 Sand bags to hold loop in place Untwisted power extension cords. Power Tools: Heat Lamp, Shop Vac, Table Saw, Grinder, and 3 Heat Guns. Procedure: We laid out a 6 x6 preformed direct burial loop and directly tied an untwisted power line directly to one of the loop s legs with cable ties. Approx. 15 of Twisted and untwisted power lines were laid over the loop. The loop was connected to 3 different detectors set to the highest sensitivity and the power was surged (turned on and off) to see if any crosstalk or false detections occurred. Each detector was tested by holding a metal bar over the loop to check if they were able to obtain a proper detection. 2

The detection test with the metal bar was repeated when the power was being surged to see if there would be any interference. Power tools were connected to the power lines until the circuit popped. The circuit was overloading at 44.5 amps. Power Tool Amps Heat Lamp 2.5 Shop Vacuum 1 Table Saw 2 Grinder 3 Total: 44.5 or 4,895 watts P o w er Li ne Loop cable tied directly to power line. Loop tied directly to power line Results: EDI LMA 1800 3

Sensitivity Level: 9 (Highest) False Detection: No Crosstalk: No Detect Metal Bar: Yes EDI Oracle Sensitivity Level: 20 (Highest) False Detection: No Crosstalk: No Detect Metal Bar: Yes The EDI Oracle has a DEFLECTOMETER streaming graph which shows the call strength over time (in 6 second intervals) The streaming graph showed no activity when the power was on or surged, it only showed activity when the metal bar was placed over the loop to check the detector. Diablo DSP-11 Sensitivity Level: N/A False Detection: No Crosstalk: No Detect Metal Bar: Yes Note: The graph activity is from the metal bar test. Results show that all the detector modules did not experience interference, or false detections when the power was on or when the power surged. There were no false detections or interference recorded on any of the detector modules. Conclusion: Loops laid over power lines are unlikely to experience false detections or interference for most common applications. 4

What this means, BD Loops comments: This is a frustrating myth that BD Loops has been trying to combat since 2013. As you can see in the test results all 3 detectors did not experience cross talk or false detections during the test. We added more power tools until we were able to trip the circuit breaker. Even with the overloaded circuit no cross talk or false detections occurred. Standard gate power feed ranges from 200-300 watts on average, our test surge went up to 4,895 watts (or over 10x). This is something that we find puzzling, the NEC (National Electric Code) requires that power lines be direct buried at least 24 below the surface (18 if under concrete slab). When power lines are run in a non metallic raceway the NEC requires a minimum burial depth of at least 18 below the surface (12 if under concrete). NEC does not apply to inductance loops. If there is no interference from power lines tied directly to a loop, where did the 3 standoff from electrical lines recommendation that is taught in gate and door industry schools come from? Why on earth would we need harder to follow standoff guidelines than the NEC? I would like to see the testing that determined this standard, it appears to be based on hearsay. Power lines are often run under the driveway, keeping a 3 stand off distance from electrical lines would make installing inductance loops impossible for a large number of applications. Why are industry schools teaching installers installation standards with no supporting evidence? Why are these schools making it harder to installers to do their jobs? 3