an ISO 9001:2008 Registered Company GOLL ST. - SAN ANTONIO, TX ph fax MINI SPACE SAVER HEAT /COOL

Similar documents
an ISO 9001:2008 Registered Company MINI SPACE SAVER HEAT /COOL/DEFROST QUZ-A VUZ-A

MINI SLIMLINE COOL VUY-A VUY-A

an ISO 9001:2008 Registered Company ShortPac HEAT/COOL (05000-QUX-A/05000-VUX-A)

COMPAC GEN II HEAT/COOL VUX-A. an ISO 9001:2008 Registered Company #10 SUCTION HOSE COMPRESSOR #8 DISCHARGE HOSE EVAPORATOR DRIER CONDENSER

SUPER GEN II HEAT/COOL VUX-A. an ISO 9001:2008 Registered Company EVAPORATOR #10 SUCTION HOSE COMPRESSOR #8 DISCHARGE HOSE DRIER CONDENSER

an ISO 9001:2015 Registered Company

1956 FORD F-100 TRUCK

Chevrolet Corvette Auxiliary Electric Condenser Fan Kit with Trinary Switch ( CCA)

Chevrolet Pickup Condenser Kit with Drier with Condenser Mounted Forward From Stock Position (021553)

1964 ½-66 Ford Mustang Condenser Kit with Drier with Driver Side Connections (011065)

Chevrolet Impala Condenser Kit with Drier (021062)

Chevrolet Chevelle Condenser Kit with Drier (021166)

an ISO 9001:2008 Registered Company

Ford Falcon, Ranchero Condenser Kit with Drier (014150)

Mopar B-Body Condenser Kit with Drier

Streamline Gen II Oval Control Panel Polished (48104-RHQ)

Chevrolet Camaro Condenser Kit with Drier (021179)

Toyota FJ40 Evaporator Upgrade Add-On Kit (751202)

an ISO 9001:2008 Registered Company

Camaro A/C Install Instructions

Gen II Heater with Defrost

Performance Automotive Air Conditioning

BC BRONCOS AIR CONDITIONING UNIT

TOYOTA FJ-40 DIRECTIONS

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST EARLY 1955 CHEVROLET PICKUP

Chevrolet Pickup Evaporator Kit (754563)

Heavy Duty Heater / Air Conditioner Model R-8545

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST CHEVROLET CHEVELLE/ EL CAMINO NOTE: INSTRUCTIONS DEPICT CHEVELLE

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST PLYMOUTH BELVEDERE

an ISO 9001:2008 Registered Company CORVETTE REV A 11/1/10, COVETTE EVAP INST PG 1 OF 24

Installation Instructions

HEAT/ COOL/ DEFROST FORD THUNDERBIRD

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST MUSTANG

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1968 CHEVROLET IMPALA

Mopar B-Body Condenser Kit with Drier

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST FORD PICKUP

specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic hi l PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST FORD TRUCK

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST CHEVROLET NOVA

Streamline Control Panel RHQ

INSTALLATION AND COMMISSIONING MANUAL. Neos 100S Integra 20X, 30S, 35X, 40X, 50X

SEA FROST SHORE ASSIST SA-1 R-12 THIS MANUAL IS SUPPLEMENTAL TO THE SEA FROST R-12 ENGINE DRIVE MANUAL INSTALLATION INSTRUCTIONS

Installation Manual Mopar Engine Compartment Upgrade Kit

PRELIMINARY INSTALLATION. Operation & Service Manual. Carrier Transicold Europe 03/09/07 Viento - Installation/Rev- #1/56

SEA FROST BAITFREEZER 110-VOLT AIR-WATER Twin Valve

A/C-HEATER SYSTEM - MANUAL

Heater with Air Conditioning. E-Series Ford Aeromaster

Installation Manual Mustang DOCUMENT # ClassicAutoAir / 3.12vs.a

CAMARO

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

INSTALL INSTRUCTIONS KK-S-HVAC SPRINTER VAN REAR HVAC SYSTEM

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

TOOLS REQUIRED: Crimping tool A/C Recovery Unit Wrench set up to 1 ¼ 4 Hole saw

WELCH INDUSTRIES - PAGE 1 OF 5

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

Installation Manual Mustang

ULTIMATE A/C BANTAM SYSTEM. INSTALLATION INSTRUCTIONS 2019 RestomodAir / 03.19

INSTALLATION INSTRUCTIONS PT-A HEAT/AC STANDARD KIT FORD E-SERIES VANS

Attach the drain tube through the hole.

CIRRUS AIRPLANE MAINTENANCE MANUAL

HEATING AND VENTILATION

Kawasaki Teryx Firestorm Heater Kit Instructions.

SEA FROST BD 12 OR 24-VOLT D.C. AIR-COOLED SYSTEM

Installation Manual. Truck Edition V-520 RT Series Model 10, 20, 30 and 50 Single Temperature Systems. TK IM (Rev.

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

2002 Dodge Caravan SE

WKS 2200 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

DUAL VOLTAGE ICE BOX CONVERSION SYSTEM 120 VOLTS A.C. & 12/24 VOLTS D.C. MODELS: SCQT-4408F-U1-L SCQT-4408F-U1-I OWNER'S GUIDE

Installation Instructions

Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS

INSTALLATION INSTRUCTIONS

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

1969 Camaro DOCUMENT # ClassicAutoAir / 3.12vs.a

Heater for BRP Commander. Caution: Before using this product, read this manual and follow all safety instructions. Owner s Manual

Heating and ventilation system,

R-2000 HEADLINER Air Conditioner Unit

Table of Contents SPECIFICATIONS Page 2. FOR THE INSTALLER Page 3. FOR THE PLUMBER Page 4. INSTALLATION Page 5. INITIAL START UP Page 6

Truck Edition V-520 RT Series Models 10, 20, 30 and 50 Single Temperature Systems TK IM (Rev. 8, 1/16)

Rotary Control Panel (49200-RHA)

DLCSRA. INSTALLATION INSTRUCTIONS Outdoor Unit Ductless Split System Sizes 09 to 36 TABLE OF CONTENTS

PROAIR Air Conditioner. CR43 Model INSTRUCTION MANUAL nvent Rev. H P/N

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

WineZone Ceiling Mount Ductless Split 15

KR Series Air Defrost Unit Coolers Operating and Installation Manual

1932 Ford Under Dash Pod with Louver Assembly (492008)

DCC-2200 / DCC-2300 CLIMATE CONTROL MODULE for Vintage Air Gen II Modules

Send Via: Direct Fax: Feedback ID: Additional Request: Action: MISSING To: DAN GRIMWOOD

Warning Do not attempt to install A/C units unless you are experienced with servicing A/C systems! Wire Cutter / Crimper Socket set

Mechman 170-Amp Alternator Cable Kit (220013)

SERVICE MANUAL FOR 6636A & 6636B SERIES TWO TON HIGH EFFICIENCY PACKAGED AIR CONDITIONERS

This site is based on a but applies to all 1971-on Saab 99 and Saab 900.

HEATING AND AIR CONDITIONING

R-8725/R-8730 Underdash Drop In Evaporator

Motor Vehicle Air Conditioning (MVAC) System operation and the refrigerant cycle

SECTION 50 - CAB CLIMATE CONTROL

Installation Instructions

Product Support Bulletin

Installation Instructions

installation and start-up instructions HUMIDIFIERS AND HUMIDISTAT

Installation Instructions

Installation Instructions

Transcription:

an ISO 9001:2008 Registered Company 18865 GOLL ST. - SAN ANTONIO, TX. - 78266 - ph.210-654-7171 - fax 210-654-3113 MINI SPACE SAVER HEAT /COOL 01000-QUX-A 01000-VUX-A 900101-VUX-A REV C 3/5/14, MINI SPACE SAVER HC EVAPORATOR KIT PG 1 OF 14

TABLE OF CONTENTS PAGES 1. COVER 2. TABLE OF CONTENTS 3. PACKING LIST 4. INFORMATION PAGE 5. PASSENGER COMPARTMENT 6. EVAPORATOR INSTALLATION 7. A/C LINES AND FITTINGS INSTALLATION 8. CONTROL PANEL INSTALLATION 9. HEATER HOSE ROUTING/INSTALLATION 10. A/C HOSE ROUTING 11. HOSE ROUTING ILLUSTRATION 12. WIRING DIAGRAM 13. ADJUSTING THERMOSTAT 14. EVAPORATOR KIT PACKING LIST 2 900101-VUX-A REV C 3/5/14, MINI SPACE SAVER HC EVAPORATOR KIT PG 2 OF 14

1. 2. 3. 4. EVAPORATOR KIT PACKING LIST No. QTY. PART No. DESCRIPTION 1 1 8 1 55302-VUE-A 63250-VUE 06250-VUE 63512-KUB EVAPORATOR SUBCASE I K KIT 2 1/2" DUCT HOSE EVAPORATOR MTG. KIT EVAPORATOR KIT 01000-QUX-A 01000-VUX-A ** BEFORE BEGINNING INSTALLATION OPEN ALL PACKAGES AND CHECK CONTENTS OF SHIPMENT. PLEASE REPORT ANY SHORTAGES DIRECTLY TO VINTAGE AIR WITHIN 15 DAYS. AFTER 15 DAYS, VINTAGE AIR WILL NOT BE RESPONSIBLE FOR MISSING OR DAMAGED ITEMS. 900101-VUX-A REV C 3/5/14, MINI SPACE SAVER HC EVAPORATOR KIT PG 3 OF 14 3

MINI SPACE SAVER HEAT/COOL IMPORTANT NOTICE-PLEASE READ FOR MAXIMUM SYSTEM PERFORMANCE VINTAGE AIR RECOMMENDS THE FOLLOWING: THIS KIT DOES NOT CONTAIN HEATER HOSE. YOU MUST PURCHASE 8 FEET OF 5/8" DIA. HEATER HOSE FROM VINTAGE AIR (31800-VUD) OR FROM YOUR LOCAL PARTS RETAILER. SAFETY SWITCHES: A COMPRESSOR SAFETY SWITCH MUST BE INSTALLED ON EVERY A/C SYSTEM. A BINARY SWITCH (PART# 24679-VUS) DISENGAGES THE COMPRESSOR CLUTCH IN CASE OF EXTREME LOW PRESSURE CONDITIONS (REFRIGERANT LOSS) OR EXCESSIVELY HIGH HEAD PRESSURE (406 PSI.) TO PREVENT COMPRESSOR DAMAGE OR HOSE RUPTURE. A TRINARY SWITCH (PART# 24678-VUS) COMBINES HI/LOW PRESSURE PROTECTION WITH AN ELECTRIC FAN OPERATION SIGNAL AT 254 PSI. COMPRESSOR SAFETY SWITCHES ARE EXTREMELY IMPORTANT SINCE AN A/C SYSTEM RELIES ON REFRIGERANT TO CARRY LUBRICATION THROUGH THE SYSTEM. SERVICE INFO: ATTENTION: SYSTEM COMPONENTS: THE COMPRESSOR, EVAPORATOR, CONDENSER & DRIER ARE CAPPED. CAPS MAY BE UNDER PRESSURE WITH DRY NITROGEN. BE CAREFUL REMOVING CAPS. DO NOT REMOVE CAPS PRIOR TO INSTALLATION. REMOVING CAPS PRIOR TO INSTALLATION WILL CAUSE COMPONENTS TO COLLECT MOISTURE AND LEAD TO PREMATURE FAILURE AND REDUCED PERFORMANCE. EVACUATE THE SYSTEM FOR 35-45 MINUTES WITH SYSTEM COMPONENTS (DRIER, COMPRESSOR, EVAPORATOR, AND CONDENSER) AT A TEMPERATURE OF AT LEAST 85 F. ON A COOL DAY. THE COMPONENTS CAN BE HEATED WITH A HEAT GUN OR BY RUNNING THE ENGINE WITH THE HEATER ON BEFORE EVACUATING. LEAK CHECK AND CHARGE TO SPECIFICATIONS. VINTAGE AIR SYSTEMS ARE DESIGNED TO OPERATE WITH R134a REFRIGERANT ONLY! USE OF ANY OTHER REFRIGERANTS IS A FIRE HAZARD AND COULD DAMAGE EITHER YOUR AIR CONDITIONING SYSTEM OR YOUR VEHICLE. USE OF ANY OTHER REFRIGERANTS WILL VOID ALL WARRANTIES OF THE AIR CONDITIONING SYSTEM AND COMPONENTS. USE OF THE PROPER TYPE AND AMOUNT OF REFRIGERANT IS CRITICAL TO PROPER SYSTEM OPERATION. VINTAGE AIR RECOMMENDS OUR SYSTEMS BE CHARGED BY WEIGHT WITH A QUALITY CHARGING STATION OR SCALE. REFRIGERANT CAPACITIES FOR VINTAGE AIR SYSTEMS (FOR OTHER SYSTEMS, CONSULT MANUFACTURER GUIDELINES) R134a SYSTEM CHARGE WITH 1.8 lbs. (1 lbs. 12 oz) OF REFRIGERANT LUBRICANT CAPACITIES: NEW COMPRESSOR - NO ADDITIONAL OIL NEEDED 4 900101-VUX-A REV C 3/5/14, MINI SPACE SAVER HC EVAPORATOR KIT PG 3 OF 14 USED COMPRESSOR - CONSULT VINTAGE AIR

INSTALLATION INSTRUCTIONS MINI/SPACE SAVER HEAT/COOL MINI SPACE SAVER HEAT/COOL THE VINTAGE AIR MINI/SPACE SAVER HEAT & COOL WAS DESIGNED ESPECIALLY FOR YOUR STREET ROD. IT WILL FIT NEATLY BEHIND THE DASH OF YOUR CAR, OUT OF SIGHT. READ THE DIRECTIONS COMPLETELY AND REMOVE ALL PARTS FROM THE BOX TO IDENTIFY EACH OF THEM WITH THE PACKING LIST. THE INSTALLATION OF THIS UNIT VARIES ACCORDING TO THE BODY MANUFACTURER OR MODIFICATIONS TO THE ORIGINAL BODY. THE COWL VENT MAY REMAIN OPERATIONAL (SEE STEP 2, BELOW). TAKE YOUR TIME AND DOUBLE CHECK BEFORE DRILLING OR CUTTING. NOTE: THE EVAPORATOR WAS DESIGNED TO FIT ON THE PASSENGER SIDE. 1. BEFORE BEGINNING, REMOVE THE COWL VENT HANDLE AND GLOVE BOX TO EASE INSTALLATION. IF THE DASH IS EASILY REMOVABLE, REMOVE IT NOW. CHECK FOR AND FILL IN ANY HOLES IN THE FIREWALL AND FLOOR. INSULATE AND SEAL THE FIREWALL, FLOOR, DOOR PANELS AND HEAD LINER TO REDUCE THE AMOUNT OF HEAT ENTERING INTO THE CAR. 2. THE EVAPORATOR SHOULD FIT WITH THE UPPER BLOWER MOTOR TOWARD THE TOP OF THE COWL. THE DUCT HOSE OUTLETS FACE THE UPPER CAVITY. THE DRAIN OUTLET Drain IS ALWAYS outlet ON is THE always BOTTOM on (DOWN) the bottom (down)side SIDE OF THE EVAPORATOR of the evaporator, (SEE FIGURE see 1, figure BELOW). 1 below. OPTIONAL KICK PANEL VENTS FIGURE 1 900101-VUX-A REV C 3/5/14, MINI SPACE SAVER HC EVAPORATOR KIT PG 5 OF 14 5

3. BRACKETS ARE FURNISHED TO MOUNT THE EVAPORATOR CASE USING THE COWL VENT (ATTACH TO FIREWALL AS SHOWN IN FIGURE 2, BELOW). 4. THE COWL VENT HANDLE WILL WORK IF MOVED TO THE SIDE. YOU CAN ALSO CONVERT TO ELECTRIC OR CABLE OPERATION. IF YOU CLOSE OFF THE COWL VENT, THE UNIT WILL FIT HIGHER IN THE CAR. NOTE: TO MOUNT THE UNIT HIGHER, SIMPLY DETERMINE THE NEW LOCATION, AND THEN MARK AND REDRILL THE BRACKET TO FIT AS DESCRIBED IN STEP 6, BELOW (SEE FIGURE 2, BELOW). 5. WHEN FITTING EVAPORATOR: TO THE DASH MOUNT HEADER A. REMOVE BLOWER MOTOR COVER. B. ATTACH FRONT AND REAR BRACKETS TO THE EVAPORATOR USING 1/4-20 -X 1/2 BOLTS. C. FIT REFRIGERATION FITTINGS WITH HOSES FOR PROPER CLEARANCE INSIDE THE CAR Page 11. (REFER TO HOSE ROUTING INSTRUCTIONS ON PAGE 11). 9/32 Holes FIGURE 2 6. HAVE A HELPER ScribeHOLD THE UNIT UP AS HIGH AS POSSIBLE, WITH THE BLOWER HOUSING AGAINST THE PASSENGER If SIDE KICK PANEL. LOCATE THE BRACKET ON THE TOP RIGHT SIDE OF THE BLOWER HOUSING. SCRIBE THROUGH THE 1/4 HOLE 9/32 IN THE BRACKET TO MARK THE FIREWALL. CHECK TO SEE IF THE LOCATION YOU MARKED LOOKS OK AND WILL CLEAR 1/4-20 OBSTRUCTIONS x 1 bolt ON and BOTH nut. SIDES Using OF THE the FIREWALL. rear evaporator IF SO, DRILL A 9/32 HOLE IN THE FIREWALL. ATTACH THE EVAPORATOR TO THE FIREWALL BY THE BLOWER MOTOR BRACKET WITH A 1/4-20 X 1 BOLT AND NUT. USING 1/4-20x1 THE REAR bolt EVAPORATOR and nut. BRACKET AS A GUIDE, MARK AND DRILL THROUGH THE 1/4 HOLE IN THE BRACKET. ATTACH THIS BRACKET TO THE FIREWALL WITH A 1/4-20 X 1 BOLT AND - NUT. THIS WILL. LOCATE This THE support EVAPORATOR bracket HORIZONTALLY. will attach NOW to SECURE the THE dash FRONT mount EVAPORATOR header SUPPORT STRAP TO THE UNIT WITH THE 1/4-20 X 1/2 BOLT. THIS SUPPORT BRACKET WILL ATTACH TO THE DASH MOUNT HEADER. WITH THE UNIT HELD IN PLACE AND LEVEL, MARK THROUGH THE 1/4 HOLE AT THE TOP OF THE BRACKET TO THE SHEET Drill METAL a 9/32 HEADER. mounting MAKE SURE hole. THAT Secure THE SPOT the MARKED mount strap WILL to PROVIDE the cowl A GOOD MOUNTING LOCATION FOR THIS 1/4-20 BRACKET. x DRILL 1 bolt A 9/32 and MOUNTING nut. HOLE. SECURE THE MOUNT STRAP TO THE COWL HEADER WITH A 1/4-20 X 1 BOLT AND NUT AS SHOWN IN FIGURE 2, ABOVE. NOTE: THE VENTS THAT ARE BEING USED SHOULD BE IN PLACE AT THIS TIME. See figure 1, page 5. 7. THE DUCT HOSE SHOULD BE PUT ON THE EVAPORATOR AT THIS POINT AND RUN TO THE VENTS TO ENSURE PROPER CLEARANCE (SEE FIGURE 1, PAGE 5). 6 900101-VUX-A REV C 3/5/14, MINI SPACE SAVER HC EVAPORATOR KIT PG 6 OF 14

HOLD TO RESIST TWISTING TIGHTEN PRESS TAPE #6 HOSE #10 HOSE #10 SUCTION HOSE FIGURE 3 LUBRICATE O'RINGS O-RING #6 LIQUID HOSE FOR A PROPER SEAL OF FITTINGS INSTALL SUPPLIED O-RINGS O'RINGS AS SHOWN AND LUBRICATE WITH SUPPLIED OIL. O-RING, O'RING, SLIDE OVER MALE INSERT TO SWAGED LIP SUPPLIED OIL OIL FOR FOR O-RINGS O'RINGS #6 O-RING O'RING #8 O-RING O'RING #10 O-RING O'RING FIGURE 3A 8. INSERT THE CAPILARY TUBE INTO THE COIL THRU THE LOCATION STICKER LOCATED ON TOP OF THE EVAPORATOR TO A DEPTH OF 4½. WITH REFRIGERATION HOSES AND DUCT HOSES ON THE UNIT, LIFT IT IN PLACE. MAKE SURE THAT THE FIREWALL FITTINGS ARE ACCESSIBLE WITH THE UNIT IN PLACE. IF NOT, TIGHTEN ALL REFRIGERATION FITTINGS INSIDE THE CAR NOW, WHILE YOU CAN REACH THEM. LIFT THE UNIT INTO PLACE, AND TIGHTEN THE BRACKET BOLTS TO SECURE TO THE EVAPORATOR. 9. ROUTE HEATER HOSES (REFER TO HEATER HOSE ROUTING INSTRUCTIONS, PG. 9). 10. WITH YOUR UNIT IN PLACE, STRETCH THE DUCT HOSE TIGHTLY TO THE DASH VENT, AND RECHECK THE LENGTH. TRIM TO ENSURE THAT THE HOSE IS ENSURED TAUT, WITH A MINIMUM OF KINKS OR SHARP BENDS IN THE HOSE. THIS WILL ENSURE MAXIMUM AIRFLOW. 11. MAKE ELECTRICAL AND/OR VACUUM CONNECTIONS, ACCORDING TO THE DIAGRAM FURNISHED ON PG. 12. NOTE: THE RED 12GA. WIRE WITH THE 30 AMP CIRCUIT BREAKER SHOULD BE CONNECTED TO A 12 VOLT POWER SOURCE OF AT LEAST 12GA. WIRE. CONNECT MOLDED PLUG WITH THE (RED, YELLOW, ORANGE) WIRES TO THE CORRESPONDING PLUG FROM THE BLOWER MOTOR. THE RED WIRE FROM THE BLOWER MOTOR WITH THE WHITE EXTENSION AND RING TERMINAL MUST BE GROUNDED. THE BLUE AND YELLOW WIRES FROM THE BLOWER MOTOR MUST BE PLUGGED TOGETHER. THE BLUE CLUTCH WIRE RUNS FROM THE THERMOSTAT TO THE COMPRESSOR SAFETY SWITCH AND FROM THE SAFETY SWITCH TO THE COMPRESSOR. BE CAREFUL TO ENSURE THAT THIS WIRE IS NOT PINCHED OR IN A POSITION TO RUB ON A SHARP EDGE AS IT GOES THRU THE FIREWALL. AN OPTIONAL VACUUM RESERVOIR WITH CHECK VALVE WILL HELP SYSTEM WORK UNDER A VARIETY OF CONDITIONS. (VINTAGE AIR PART #31200-VUS VACUUM RESERVOIR). 900101-VUX-A REV C 3/5/14, MINI SPACE SAVER HC EVAPORATOR KIT PG 7 OF 14 7

IF PREVIOUSLY REMOVED, REINSTALL DASH AND INSURE THAT THE DUCT HOSE IS SECURELY ON THE DASH VENT HOSE ADAPTERS. DON T FORGET TO WRAP ANY EXPOSED #10 FITTINGS INSIDE THE CAR TO PREVENT CONDENSATION. CONTROL PANEL OPERATION IF YOU ARE USING AN OPTIONAL CONTROL PANEL, REFER TO THE INSTRUCTIONS FURNISHED WITH THE PANEL FOR OPERATION. CHECK OPERATION (SEE FIGURE 4). THE SWITCH ON THE LEFT IS THE FAN SWITCH - CONTROLS 3 SPEED FAN MOTOR. THE SWITCH ON THE RIGHT IS THE MODE SELECTION. FULL COUNTER-CLOCKWISE POSITION IS ECONOMY POSITION. AMBIENT TEMPERATURE AIR SHOULD COME OUT OF DASH VENTS. IN THE FIRST POSITION (A/C POSITION), COLD AIR SHOULD COME OUT OF THE DASH VENTS. THE SECOND POSITION (HEAT POSITION), HOT AIR SHOULD COME OUT OF THE FLOOR VENT. IF VACUUM OPERATED, THE HEATER CONTROL VALVE SHOULD BE RECEIVING A VACUUM SIGNAL AND BE OPEN. FAN SPEED CAN BE OPERATED IN ANY MODE POSITION NOTE: WHEN IN DEFROST MODE POSITION TURN THERMOSTAT KNOB FULL COUNTER CLOCKWISE AND THEN CLOCKWISE 1/8 TURN OR UNTIL THERMOSTAT CLICKS ON, THIS WILL GIVE OPTIMUM DEFROST PERFORMANCE. OFF LOW MED. HIGH ECONO A/C HEAT 8 FAN SWITCH FIGURE 4 MODE SWITCH 900101-VUX-A REV C 3/5/14, MINI SPACE SAVER HC EVAPORATOR KIT PG 8 OF 14

HEATER HOSE INSTALLATION AFTER THE EVAPORATOR IS IN PLACE, RUN 5/8 HEATER HOSE FROM THE HEATER TUBE NEAREST THE BLOWER ON THE EVAPORATOR THRU THE FIREWALL OR BEHIND THE KICK PANEL THRU FLOOR TO THE INTAKE MANIFOLD HEATER CONNECTION. INSTALL THE HEATER CONTROL VALVE IN THIS LINE. (PRESSURE) SEE FIGURE BELOW. (BE SURE TO FOLLOW FLOW ARROW ON HEATER CONTROL VALVE) INSTALL 5/8 HEATER HOSE ON THE REMAINING HEATER TUBE. ROUTE HOSE THRU FIREWALL OR BEHIND KICK PANEL THRU FLOORBOARD AND OUT TO WATER PUMP CONNECTION. (SUCTION) FILL RADIATOR WITH AT LEAST A 50/50 MIXTURE OF APPROVED ANTIFREEZE AND WATER. IT IS THE OWNER S RESPONSIBILITY TO KEEP THE FREEZE PROTECTION AT THE PROPER LEVEL FOR THE CLIMATE IN WHICH THE VEHICLE IS OPERATING. FAILURE TO FOLLOW ANTIFREEZE RECOMMENDATIONS WILL CAUSE HEATER CORE TO CORRODE PREMATURELY AND POSSIBLY BURST IN THE A/C MODE AND/OR FREEZING WEATHER, VOIDING YOUR WARRANTY. CHECK COMPLETE A/C ASSEMBLY FOR PROPER OPERATION. VINTAGE AIR RECOMMENDS THAT ALL A/C SYSTEMS BE SERVICED BY A CERTIFIED AUTOMOTIVE AIR CONDITIONING TECHNICIAN ONLY. SEE INSIDE COVER FOR SERVICE INFORMATION. START ENGINE AND RUN, UNTIL NORMAL OPERATING TEMPERATURE IS REACHED. PLACE SWITCH IN HEAT POSITION (SEE FIGURE 4, PAGE 8), AND SELECT FAN SPEED DESIRED. THE SYSTEM WILL HEAT THE VEHICLE. IMPORTANT: (BE SURE THE ENGINE THERMOSTAT HAS OPENED, AND THE APPROVED ANTIFREEZE MIXTURE HAS BEEN CIRCULATED THRU THE HEATER CORE BEFORE TESTING THE A/C MODES). WHEN VALVE IS CLOSED, INLET SIDE OF VALVE SHOULD BE HOT AND OUTLET SIDE SHOULD BE COOL. WHEN THE VALVE IS OPEN, BOTH INLET AND OUTLET SIDES SHOULD BE HOT. EVAPORATOR UNIT CLAMPS HEATER CONTROL VALVE GROMMETS CLAMPS TO VACUUM SOLENOID FROM MANIFOLD TO HEATER CORE 900101-VUX-A REV C 3/5/14, MINI SPACE SAVER HC EVAPORATOR KIT PG 9 OF 14 9

PUSH THE 5/16 I.D. HOSE ONTO THE STRAIGHT #6 FITTING. (SEE HOSE ROUTING ILLUSTRATION ON PG. 11). INSTALL THE FITTING ONTO THE EXPANSION VALVE (FINGER TIGHT). PUSH THE 1/2 I.D. HOSE ONTO THE STRAIGHT #10 FITTING, AND INSTALL THE FITTING ONTO THE #10 LINE ON THE EVAPORATOR. (SEE HOSE ROUTING ILLUSTRATION PG. 11). AT THIS TIME, TRY TO DETERMINE WHERE YOU WANT YOUR LINES TO GO THRU THE FIREWALL. MOVE THE HOSES TO THAT POINT. HOLD THE FITTINGS UP TO THEIR RESPECTIVE HOSES, AND DETERMINE IF THE HOSES WILL CONFORM TO THE LOCATION FOR THE BULKHEAD FITTINGS OR OPTIONAL BULK- HEAD PLATE (VINTAGE AIR PART #34215-VUQ OR 34217-VUQ). THE ½ HOSE IS HARD TO BEND AT A SHARP ANGLE, AND THE FITTINGS TAKE UP A CERTAIN AMOUNT OF SPACE. BEFORE YOU DRILL HOLES IN YOUR FIREWALL, MAKE SURE THAT YOU CAN MAKE THE HOSES FIT WHERE YOU HAVE PLANNED. THE ENGINE COMPARTMENT APPEARANCE IS A CONSIDERATION WHEN CHOOSING THIS LOCATION. WHEN YOU HAVE DECIDED WHERE YOU WANT TO PLACE YOUR BULKHEAD FITTINGS, MARK THESE POINTS WITH A GREASE PENCIL, AND MAKE A TEMPLATE FROM THE INSIDE LOCATING WHERE THE HOLES WILL BE CUT. WITH THIS TEMPLATE, LOCATE THE SAME POINTS ON THE OUTSIDE OF THE FIREWALL. MARK THESE POINTS WITH A GREASE PENCIL. DETERMINE THE BEST LOCATION FOR THE DRIER THAT WILL ALLOW ADEQUATE ROOM FOR THE HOSE AND FITTINGS THAT CONNECT THE DRIER TO THE BULKHEAD FITTING. MOUNT THE DRIER. (KEEP THE DRIER CAPPED AS MUCH AS POSSIBLE, IF YOU MUST SCREW THE FITTING TO THE DRIER, TAPE IT CLOSED). AT THIS POINT, CUT HOLES FOR BULKHEAD FITTINGS, AND INSTALL THEM. USING THE HOSE ROUTING ILLUSTRATION AS A GUIDE, ROUTE REMAINING A/C LINES, AND CUT TO LENGTH. INSTALL A/C VENTS THAT WILL BE USED AT THIS TIME. NOTE: THE DRIER IS USUALLY MOUNTED WHERE YOU HAVE ROOM FOR IT. JUST REMEMBER TO MOUNT IT IN THE COOLEST SPOT POSSIBLE AND VERTICALLY SO THE SIGHT GLASS IS DIRECTLY ON TOP. (NOT NEXT TO THE EXHAUST MANIFOLD). IT CAN BE MOUNTED INSIDE THE VEHICLE AS WELL. CENTER OUTLET: YOU MAY USE THE CENTER PANEL FURNISHED, OR YOU CAN MOUNT THE VENTS IN DASH. IF YOU USE THE CONTROL PANEL, THE TOP MOUNTING LIP SHOULD BE BACK ¼ x ½ FROM LOWER LEADING EDGE OF DASH. LOCATE THE 2½ I.D. HOSE, AND ROUTE FROM THE DASH VENTS TO THE EVAPORATOR. AT THIS TIME, YOU SHOULD HAVE THE REFRIGERATION HOSES CUT TO THEIR PROPER LENGTH. PAY CLOSE ATTENTION TO THE ORIENTATION OF ANY HOSE WITH TWO ANGLED FITTINGS. ANY HOSE WITH TWO ANGLED FIT- TINGS MUST BE MARKED FROM THE HOSE TO THE FITTINGS TO ASSURE THEY WILL REMAIN IN THIS POSITION AFTER CRIMPING. THE RUBBER HOSE IS ONLY CAPABLE OF A MINIMAL AMOUNT OF TWIST TO AID ALIGNMENT. REMOVE HOSES AND CRIMP ENDS. IF YOU DO NOT HAVE ACCESS TO THE PROPER EQUIPMENT, YOU MUST TAKE THEM TO A QUALIFIED A/C SERVICE CENTER FOR CRIMPING. (SEE CRIMPING INSTRUCTIONS SUPPLIED WITH THE HOSE KIT). WITH THE EVAPORATOR TRIAL FIT COMPLETE, YOU MAY REMOVE UNIT AND LOWER IN VEHICLE. AFTER CRIMPING HOSES, LOCATE THE #6 A/C HOSE WITH THE STRAIGHT FITTING. LUBRICATE A #6 A/C O-RING AND THE THREADS ON THE FITTING, AND INTSTALL ON THE EXPANSION VALVE. TIGHTEN CAREFULLY. REFER TO FIGURES 3 & 3A, PAGE 7. 10 LOCATE THE #10 A/C HOSE WITH THE STRAIGHT FITTING. LUBRICATE A #10 O-RING AND THE THREADS ON THE FITTING, AND INSTALL ON THE #10 LINE OF THE EVAPORATOR. TIGHTEN CAREFULLY. REFER TO FIGURES 3 & 3A, PAGE 7. WRAP THE #10 FITTING WITH PRESS TAPE, AND COVER ALL EXPOSED METAL SURFACES. (DO NOT WRAP THE #6 HOSE, FITTING, OR THE HEATER CORE TUBES). SEE FIGURE 3, PAGE 7. 900101-VUX-A REV C 3/5/14, MINI SPACE SAVER HC EVAPORATOR KIT PG 10 OF 14

TYPICAL HOSE ROUTING DIAGRAM EVAPORATOR SAFETY SWITCH BINARY (ENGINE DRIVEN FAN) TRINARY (ELECTRIC FAN) # 10 SUCTION HOSE COMPRESSOR RECEIVER/DRIER (NOTE FLOW DIRECTION) CONDENSER # 8 DISCHARGE HOSE #6 LIQUID LINE DIRECTION OF REFRIGERANT FLOW INDICATED BY ARROWS 11 900101-VUX-A REV C 3/5/14, MINI SPACE SAVER HC EVAPORATOR KIT PG 11 OF 14

WIRING/VACUUM DIAGRAM HEAT & COOL (REQUIRED) COMPRESSOR SAFETY SWITCH (BINARY TYPE) V.A. #24677-VUS BLUE A/C CLUTCH YELLOW RED ORANGE BLUE BLACK BLACK MODE SWITCH FAN SPEED SWITCH A/C THERMOSTAT L M H L M H ORANGE B C BLACK B C RED YELLOW WHITE GROUND POWER RELAY 87 87a 86 85 30 BLUE RED HIGH BLOWER RELAY WHITE GROUND BLUE 87 87a 86 85 30 PURPLE AUX. ORANGE BLOWER MOTOR RED CONNECT TO KEY ON IGNITION SOURCE (5AMP FUSE) BLUE YELLOW PLUGGED TOGETHER WHITE GROUND A/C HEATER DOOR RED HEATER RED CONTROL VALVE BLACK TEE VACUUM SOLENOID WHITE GROUND BAT. 30 AMP CIRCUIT BREAKER TO BATTERY OR BATTERY TERMINAL ON REGULATOR, ALTERNATOR, OR STARTER SOLENOID. BLACK ENGINE VACUUM TO INTAKE MANIFOLD VACUUM SOURCE VACUUM RESERVOIR OPTIONAL VACUUM RESERVOIR VINTAGE AIR PART#31200-VUS 12 WIRES = VACUUM LINES = RED BLACK 900101-VUX-A REV C 3/5/14, MINI SPACE SAVER HC EVAPORATOR KIT PG 12 OF 14

THERMOSTAT (TYPICAL) COLDER CLOCKWISE ADJUSTABLE THERMOSTAT ADJUSTABLE KNOB (TYPICAL) CAPILLARY TUBE TO EVAPORATOR COIL WARMER COUNTER CLOCKWISE FIGURE A MINI SPACE SAVER EVAPORATOR AIR CONDITIONING ADJUSTMENTS: THE AIR CONDITIONER THERMOSTAT CONTROLS COIL TEMPERATURE, IT IS SHIPPED ADJUSTED FULLY COLD (CLOCKWISE), IN THE MAJORITY OF CASES THE A/C WILL OPERATE CORRECTLY AS SHIPPED. TURNING THE KNOB ON THE THERMOSTAT TO THE RIGHT (CLOCKWISE) MAKES THE SYSTEM OPERATE COLDER. IF THE THERMOSTAT IS SET TOO COLD THE EVAPORATOR WILL "ICE UP" - THE EVAPORATOR COIL IS RESTRICTED WITH ICE AND COLD AIR FLOW WILL BE REDUCED. TURNING THE KNOB TO THE LEFT (COUNTER CLOCKWISE) MAKES THE SYSTEM OPERATE WARMER. THE COMPRESSOR CLUTCH WILL CYCLE OFF FREQUENTLY AND THE A/C SYSTEM WILL NOT GET AS COOL AS IT COULD. ADJUSTING A/C THERMOSTAT 1.) SYMPTOM: THE A/C WORKS WELL AT FIRST THEN QUITS COOLING. THE AIR FLOW FROM THE VENTS IS LOW AND THE COMPRESSOR CYCLES INFREQUENTLY. SOLUTION: THE THERMOSTAT IS SET TOO COLD AND THE EVAPORATOR IS "ICING UP" AND RESTRICTING AIR FLOW. ALLOW THE ICE TO MELT AND SET THE THERMOSTAT WARMER (COUNTER CLOCKWISE) 10% OF A TURN EACH ADJUSTMENT UNTIL THE SYMPTOMS DIMINISH. 2.) SYMPTOM: A/C NEVER GETS COLD AND THE COMPRESSOR CLUTCH CYCLES FREQUENTLY. SOLUTION: THE THERMOSTAT IS SET TOO WARM. SET THE THERMOSTAT COLDER (CLOCKWISE) 10% OF A TURN EACH ADJUSTMENT UNTIL THE COMPRESSOR CLUTCH CYCLES INFREQUENTLY. AVOID SETTING THE THERMOSTAT TOO COLD. 3.) SYMPTOM: THE A/C NEVER GETS COLD, SOMETIMES EVEN BLOWS HOT, AND THE A/C COMPRESSOR CLUTCH INFREQUENTLY CYCLES OFF. SOLUTION: THE HEATER MAY BE ON AT ALL TIMES. CAREFULLY FEEL AROUND THE HEATER HOSES AT THE FIREWALL. THEY SHOULD BE COLD WHEN THE A/C IS ON. IF THE HOSES ARE HOT THEN: A) - THE HEATER CONTROL VALVE MAY BE INSTALLED BACKWARDS. CHECK THE FLOW DIRECTION ARROW ON THE VALVE AGAINST THE ILLUSTRATION IN YOUR INSTALLATION INSTRUCTIONS. B) - IF CABLE OPERATED: THE VALVE MAY BE MISADJUSTED. C) - IF VACUUM OPERATED: IT MAY BE GETTING VACUUM AT ALL TIMES (CHECK ELECTRIC SOLENOID). 900101-VUX-A REV C 3/5/14, MINI SPACE SAVER HC EVAPORATOR KIT PG 13 OF 14 13

1. 2. 3. 4. EVAPORATOR KIT PACKING LIST No. QTY. PART No. DESCRIPTION 1 1 8 1 55302-VUE-A 63250-VUE 06250-VUE 63512-KUB EVAPORATOR SUBCASE I K KIT 2 1/2" DUCT HOSE EVAPORATOR MTG. KIT EVAPORATOR KIT 01000-QUX-A 01000-VUX-A CHECKED BY: PACKED BY: DATE: 1 2 4 3 900101-VUX-A REV C 3/5/14, MINI SPACE SAVER HC EVAPORATOR KIT PG 14 OF 14