Mitocell: Instructions for Use

Similar documents
Assembly of a Microbial Fuel Cell

Operating Instructions

I N ST R UC T I ON MODEL 2612 & 2712 SLICERS MODELS 2612 ML ML FORM (12-98) 2612 SLICER

Quick Start Guide LIQ-QSG-Hx438, Rev A June Rosemount Hx438. Amperometric Steam Sterilizable Dissolved Oxygen Sensors

Dissolved Oxygen Sensors

, '0''/).''$ /*'( 1'%* 00) ',))% *)) $ 3:36;$ !"## $%& '()*+,,,( '()*

Glass and Dishwashers AMX / AUX Series

RK/ RK Oxygen Detector Operator s Manual

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600

Ion OneTouch Template Kit Publication Part Number Revision E Date 31 October 2011

ExStik DO600 USER GUIDE. Dissolved Oxygen Meter. 99 Washington Street Melrose, MA Phone Toll Free

Tracer DO PockeTester TM Code 1761

Hot Chocolate Dispenser

º CP0398/01 Padholder assy Switch 2-cup

OPERATION MANUAL KLEENSCREEN FILTRATION SYSTEM SUPPLEMENT INSTRUCTION MANUAL FOR: Gas Fryer Models. Electric Fryer Models

7911A Constant Temperature Ice Bath. User s Manual

Introduction... 3 Setup & Suggestions... 4 Basic Use... 4 Setting Time... 4 Setting Temperature... 5 Setting Height / Pressure...

ROTARY VACUUM EVAPORATOR RVO 004

RK/ RK Carbon Monoxide Detector Operator s Manual

HydroFlux Welder Torch System T0-102 / T0-103

Glass and Dishwashers AMX / AUX Series

1 L Rotary Vacuum Evaporator Instruction Manual

CT-7 Series Toxic Gas Transmitter Operator s Manual

MODEL SK2750. COMPRESSOR SERVICE KIT For use on 2750 Series Compressors

Manual Diffusion Cell Operation Manual REV. B DATE: 19Sep2012

Service Manual 26 Self Trimming Export Fireplace with 3 Stage On/Off Remote

Enteral Pump Instructions for Use To Assemble When the low

AA Z** V2** W** U1* V** U2** USER MANUAL U* E D L U3* M N S ** T* O Q P P3 P2 P1 R** AD* PRINTED IN P.R.C /01

BAMOSOFT Control. Water hardness monitor INSTRUCTIONS MANUAL DUR. BAMOSOFT Control. Water hardness monitor / M1 01 C

2006G2 OPERATING INSTRUCTIONS. 2006G2 Pressure-Vacuum Hand Pump July 2011 SOILMOISTURE

RK CO 2 Transmitter Operator s Manual

INSTRUCTIONS FOR SAFE USE INSTRUCTIONS FOR SAFE USE

BMW E36 Thermostat Removal And Coolant Flush

POWER WASHER MODEL NO: JET 9000 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING: Do not use the machine without reading this manual PART NO:

MS200/300/400 Magnetic Stirrer. Instruction Manual

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

OPERATING & SERVICE PARTS MANUAL 700ES ENERGY SMART WRAPPER SERIES C

AUC Cell Washer. User Manual

OPERATING & SERVICE PARTS MANUAL 700ES ENERGY SMART WRAPPER SERIES B

RK Carbon Monoxide Transmitter Operator s Manual

Operating Instructions

I N ST. MODEL 2912PS AUTOMATIC SLICER... with Portion Scale 701 S. RIDGE AVENUE TROY, OHIO

SERVICE MANUAL REFRIGERATION

MiniCO, MiniH 2 S, MiniOX, MiniOX Remote, MiniCl 2. , and MiniClO 2. Responder Detectors Instruction Manual "! WARNING

Operator s Manual CAYENNE HEAT N SERVE 4/3 RECTANGULAR RETHERMALIZER ENGLISH

INSTALLATION AND MAINTENANCE GUIDE TRENDY 1000 T ELECTRONIC LAVATORY FAUCET

RK-02 Multi Point Detector Operator s Manual

SINGLE SPEED SYRINGE PUMP

FACSCalibur Startup Procedures

ALLERGEN MIXING ASSISTANT

Fluoride. by ProMinent May 2016

kéìíê~=iqd=qìåöëíéå=dêáåçéê= lééê~íáçåë=j~åì~ä=

Cleaning the internal optics surfaces

MODEL COMPRESSOR SERVICE KIT For use on Midmark Power Air Oil-less Compressor Models P21, P22 & P32

PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO:

6. Cooling System XCITING 400i. This chapter covers the location and servicing of the cooling system components for the KYMCO XCITING 400i.

FAILURE TO ADHERE TO THESE WARNINGS CAN RESULT IN FIRE, SERIOUS INJURY, ELECTRICAL SHOCK AND/OR DEATH. Technical Service

SuperKlean Washdown Products

INSTALLATION & OPERATION Rev 1.00A DISTRIBUTED EXCLUSIVELY BY CMA DISHMACHINES KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841

Water Distiller Service Manual

AEM EASY DRUM M A N U A L

Commercial Air Purifier. Model HMA-3500-TC. Air Purification Unit. User Guide. Knock out odors at their source

Tornado Operations & Maintenance Manual

ASSEMBLY & OPERATING INSTRUCTIONS

Service Manual 26 Self Trimming Fireplace with 3 Stage Remote

Combustible Gas Sample-Draw Detector Operator s Manual

Service Manual. Senseo Up HD7880/80 HD7880/81 14/04. Philips Consumer Lifestyle

Determination of the enthalpy of vaporization of liquids

Instruction Manual. Self-Leveling Rotary Laser Level Model Nos and

RK Hydrogen Sulfide Transmitter Operator s Manual

Technical Data. Name: ERIKA Automat fully automatic machine to divide and to round dough pieces of the same size

Instruction Manual CHLORALERT TM Series T17CA4000 Chlorine Gas Leak Detector CAPITAL CONTROLS

Reliability in Laboratory Centrifuges Since Operator s Manual. Models 614B, 614L, 614U/UL and 614V/VL Laboratory Centrifuge. Rev. 5.

Refrigerator KE T

ACME DIAGNOSTICS STANDARD OPERATING PROCEDURE

Daily Cleaning Instructions: KL1Plus

Pos-D Positive-Displacement Pipette for Problem Liquids

RAPIDS 4WD ROBOTIC POOL CLEANER SETTINGS AND TROUBLESHOOTING GUIDE

INSTRUCTION MANUAL. Stirring hotplate (with probe and stand) Brand : (Dragon laboratory)

FLAME115 INFRARED HEATER SERVICE MANUAL INDEX FIRE 115 WARNING

D3000. Installation & Setup Guide

Magnetic Stirring Systems with Heat

Use and Care Guide. Over the Patient Units and Swing Mount Units

Using the Lely Robot Sampler CanWest DHI Robot Manual

INSTRUCTION MANUAL CMY

D14 & D18 Upright Vacuum

I N S T R U C T I O N S

Table of Contents. English

OPERATOR'S MANUAL HD-500/550

Hozelock Ltd. Midpoint Park, Birmingham B76 1AB. England Tel: +44 (0)

ValkyrieTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S.

Service Manual. Model Number: DFR2651L. UL Part Number

RK Multi Point Detector Operator s Manual

Orrin. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR OWNER S MANUAL

OPERATOR'S MANUAL HD-400

Sanitise Syrup Lines & Valves. Taylor PH61 Cleaning every 14 days

SERVICE MANUAL DISHWASHERS DIVA ACCESSIBILITY DISHWASHERS

ZD-985 Desoldering Station

Multi-Mode Electrode pro

Transcription:

Mitocell: Instructions for Use 1 Introduction The Mitocell (MT200) is designed for the measurement of the respiration rate of either 50 or 100µl sample volumes of mitochondria and cell suspensions. The larger Mitocell (MT200A) is designed for volumes of 0.3, 0.5 and 1.0ml sample volumes. The glass top with a central channel forms the water jacket. It is secured on to the grey base unit with a black plastic clamp ring. When the polycarbonate plunger is inserted into the central channel of the glass top and the electrode is inserted in the bottom of the base unit the small respiration chamber is formed. The plunger has a central capillary, through which substrates or inhibitors may be injected during a respirometry run. The grey base unit contains the built in magnetic stirrer which rotates the spinbar in the respiration chamber. (Diagram 1). Both mitocells are supplied with stir bars, volume adjustment rod(s) (setting pieces) and hexagon key. The spinbars for the MT200 should be kept on the magnet in order to maintain their magnetic properties when not in use. The MT200 is supplied with a red volume adjustment rod, and is supplied pre-assembled with the volume set to 50 microlitres (allowing for a stir bar in the chamber). (Diagram 2). The MT200A is supplied with three volume adjustment rods. The red rod is for volume of 0.3ml, the white rod is for a volume of 0.5ml and the black rod is for volumes of 1.0ml. The MT200A is supplied pre-assembled with the volume set to 0.5ml. (Diagram 3) Both Mitocells are designed to work with the standard Strathkelvin oxygen electrode (not supplied).

Diagram 1 Diagram 2 Diagram 3

2 Assembly Connect a pumped source of constant temperature water (regulated to ± 0.1 C) to the two tubes on the rear of the Mitocell. Allow the water to enter the water jacket slowly at first, to avoid the production of small air bubbles, which can impair visibility of the respiration chamber. Invert the Mitocell until all air bubbles have been flushed away. Unscrew the black cap of the electrode holder at the base of the unit. Ensure that the electrode and inside of the electrode holder are thoroughly dry. Insert the electrode and pass the cap over the electrode cable and screw it on tightly. The electrode tip now forms the base of the respiration chamber. Remove the plunger from the cell and drop a stir bar into it. If you have a 781 oxygen meter or a 928 interface, insert the plug from the 5 V mains power unit into the lower of the two power sockets on the back of the unit, and plug the power unit into the mains supply. If you have a 782 oxygen meter, connect the link power cable between the 5Vdc out socket on the rear of the 782 meter and the lower power socket on the back of the Mitocell. Switch the power unit on. The indicator on the Mitocell panel will illuminate. The integral stirrer can then be turned on and off by pressing the stirrer on/off membrane button, showing a stir bar symbol, just below the indicator light. When the stirrer is operating the light flashes. Connect the oxygen electrode cable to the socket on the front of the 781 oxygen meter or 928 interface or the back of the 782 oxygen meter. You are now ready to calibrate the electrode. 3 Calibration of the electrode The electrode should be recalibrated each day, and should be left connected to the meter, with the meter switched on, if in daily use. Read the section in the 781, 782 or 928 manual on electrode calibration. High point calibration: Circulate water at the temperature of the experiment, through the water jacket. Remove the plunger and half fill the respiration chamber with aerated water. Switch on the stirrer. Calibrate the high point, then suck out the water and dry the chamber with a wick of absorbent tissue. Zero calibration: Half fill the respiration chamber with sodium sulphite solution. It is not necessary to stir. Complete the zero calibration, then suck out the solution and wash out several times with distilled water to remove all traces of the sulphite solution. Finally dry the chamber with a wick of absorbent tissue. 4 Running an experiment To run an experiment, pipette the required volume of the respiring suspension plus 10µl into the respiration chamber. (i.e for a volume of 50µl pipette 60µl). The suspension should already be at the same temperature as the Mitocell. (The extra volume allows liquid to partially fill the central channel of the plunger, which

minimises the diffusion of oxygen from the air). Make sure no air bubbles are introduced with the sample during this procedure. Insert the plunger into the respiration chamber, displacing the air and excess liquid into the capillary of the plunger. Turn on the stirrer and start recording the oxygen change. During the course of an experiment, substrates or inhibitors can be injected directly into the chamber, using the Strathkelvin modified syringe supplied. (spares can be purchased if required). These syringes have a spacer which ensures that the needle does not touch and possibly damage the membrane of the electrode. During injection hold the plunger in place to avoid the introduction of air bubbles. At the end of the run remove the plunger and spin bar. Return the stir bar to its magnet in order to keep it magnetised and ready for use (MT200 only). Between runs, the contents of the respiration chamber can be removed by suction, followed by rinsing with distilled water. Finally remove any residual moisture with a wick of absorbent tissue. Take care not to damage the electrode membrane during this process. 5 Changing the volume of the chamber 1. Drain the water from the Mitocell as in Section 6 below. Remove the electrode. Remove the plunger. 2. Unscrew the black plastic clamp ring to release the glass top. 3. (i) For the MT200 remove and invert the glass top. (ii) For the MT200A remove the glass top 4. (i) For the MT200 insert the longer end of the red volume rod into the base of the central channel for a 100 µl sample volume or the shorter end for 50 µl. (ii) For the MT200A drop the red rod into the central channel for 0.3 ml, white for 0.5 ml and black for 1ml 5. (i) For the MT200 - while holding the rod in place insert the plunger into the other end of the channel until it seats on the rod. (ii) For the MT200A Insert the plunger into the central channel on top of the rod. For both the MT200 and MT200A. Insert the hexagonal key into the small hole on the side of the circular adjustment collar on the plunger. Use the key to loosen the set screw inside the collar. Slide the collar until it rests on the of the glass top. 6. Secure the collar to the plunger by tightening the collar set screw with the hexagon key, just tight enough to prevent the collar moving. Take care not to over-tighten the screw as this may fracture the plunger. 7. Remove the volume rod, refit the glass top and secure with the plastic clamp ring. Before inserting the electrode ensure that electrode and inside the electrode holder have been dried thoroughly. Re-insert the electrode and screw its cap on tight.

6 Cleaning the chamber and water jacket If you need to clean the complete unit, proceed as follows: Switch off the pumped water supply. Disconnect the outlet and inlet water supply tubes and drain the water jacket. Remove electrode (it is important that the electrode is removed before disassembly). Unscrew the clamp ring and remove the glass top. Wash the glass top in detergent solution, followed by several rinses. Ensure that the glass top is completely dry before reassembly. 7 Electrode Care See 781, 782 or 928 manual. 8 Setting stirring speed The default speed for the stirrer is 1100 rpm, which is optimal for the small stainless steel stir bar of the MT200. It is possible to select a different speed by carrying out the following steps: To set selected speed: 1. Ensure that the unit has been powered off for at least 1 minute. 2. Hold down the button on the top panel and turn on the power (turn on at wall, or plug in the power cable). 3. Continue to hold down the button until the rapid indicator flashes stop (after 80 flashes). 4. The indicator will then flash slowly 10 times. Release the button after the number of flashes that corresponds to the speed desired. No. flashes Speed (rpm) 1 400 2 500 3 600 4 700 5 800 6 900 7 1000 8 1100 (default) 9 1200 10 1300 To reset default speed: 1. Ensure that the unit has been powered off for at least 1 minute. 2. Hold down the button on the top panel and turn on the power (turn on at wall, or plug in the power cable). 3. The indicator will flash rapidly. Release the button while it is doing so.

9 Tips and troubleshooting The stir bar may be most easily removed from the respiration chamber by using a syringe needle or straightened paper clip to pick it up magnetically. Take care not to touch the electrode membrane. An increase in noise level on the oxygen traces when the stirrer is switched on usually indicates that the electrode membrane is damaged. A new membrane should be fitted. If the stirrer does not start when the stirrer on/off button is pressed (ie. the indicator does not begin to flash), unplug the power lead from the back of the Mitocell and plug it in again. Alternatively, switch off at the wall, wait 15 seconds and than switch on again. 10 Power supply Caution use only the 5 volt power unit provided. This can operate a number of Mitocells, each one powered from its neighbour with a link cable supplied by Strathkelvin Instruments. If your Mitocell was purchased with a Model 782 oxygen meter, a link cable was supplied instead of a power unit. This should be plugged into the 5V dc out socket on the rear of the 782 meter. Company/manuals/mitocellmanual.doc 15.12.05.