CO1709 INSTRUCTION MANUAL

Similar documents
ElEctronIc 2 DIal tap timer co1701 InstructIon Manual

Pixel Pot Vertical Planting Kit

Your Pope Simple Set Automatic Tap Timer

Your GardenMate Easy Dial Automatic Tap Timer

Certified to CSA STD. C22.2 No.117

EH " (40cm) Remote Control Wall Fan

MICRO IRRIGATION Installation Guide. Installation hints Wetta product guide Design your own irrigation system

POLIVAC PREDATOR MKIII OPERATIONS MANUAL & TROUBLE SHOOTING GUIDE

New. Products. 2017/2018 Season

OPTIONAL SPRING MTG HANGING CENTRES WATER CONN'S: TWO BSP MALE. 19 mm (3/4") ELECTRICAL CONDUIT HOLES ACCESS PANEL OUT (WATER) IN 485 MOUNTING

2-ZONE EASYFIT INTRUDER ALARM

S D HWP 77, 96. Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance. Fig. 1 Nomenclature. Fig.

CRX Single Zone Wireless Controller. Installation and User Guide. 1. Getting to know your CRX2 wireless controller

PolyMax H1-10 Dutch Bucket System

S Y D. HWP 35, 47, 58 (c/w EC Motor & UC7 Controller) Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance

Parts & Material Included

HEAT PUMP PROGRAMMABLE THERMOSTAT

2-ZONE EASYFIT INTRUDER ALARM

Set & $ave. Model Programmable Thermostat. installation and operation manual

Agrifim A675CT Timer. Frequently Asked Questions

AC-12200E Portable Air Conditioner

INSTRUCTION BOOK. BioDoser. Simple, Fully Programmable Dosing System. BioDoser. Version 1.0b, 25-Oct Please read before you call us for advice.

Orbit ArizonaMist. Installation ra

PolyMax H2-24 Dutch Bucket System

Installation and Operating Instructions

CONTENT PAGE INFORMATION INSTALLATION BREWER SETUP BREWING CLEANING KEY BREWER GRINDER MANUAL MODE DILUTION GRINDER MODE PACKS MODE

Portable Air Conditioner

Battery Powered In-line Valve with Watering Timer RBC 7000

Vertical Planting Kit with Watering System Installed

EH0533 Indoor Climate Control

PIPE DREAMS 96. Aeroponic Garden IMPORTANT:

PINK MAGNETIC RECUMBENT BIKE

Battery Powered Actuator with Watering Timer RBC MVA

Operators manual Slim/B Water heater

Instruction Manual. Model: EPA 16 Portable Airconditioner

SAN JUAN FRESH WATER COOLING SYSTEMS

USER MANUAL AKC cm 4 Burners, Stainless Steel Hob

OWNER S MANUAL. How to install, operate and maintain your. EcoWater Systems Automatic Sediment Filter. EcoWater Systems Poland

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For models WA-1010E, WA-1010H, WA-1010M

DIY GUIDE.

DIY. Home Irrigation Installation Planner

WSK300 Multifunction Wall Control

WARNING Important Safety Information

A HEATER KIT With Diesel Engine Connection Fittings

Reverse Cycle Split System Air Conditioner

WATERING AND FEED KITS

Hodge Clemco Ltd. MJC Mini Cartridge Filters Owners Manual. TSOM 556 Date of issue 13/07/04. Hodge Clemco Ltd

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

How to Build A State-of-the-Art, High Yielding Aeroponic Growing System

Programmable Thermostat

Water Distiller Service Manual

PLEASEREADANDSAVETHESEINSTRUCTIONS. NewAir AC-14000E, AC-14000H Portable Air Conditioner Owner's Manual

Flexible Gas Tubing. Semi-Rigid Corrugated Stainless Steel Tube System PRODUCT GUIDE.

CONTENTS. 1.1 General terms of delivery Voltage Water treatment... 2

HydroCycle Vertical Aeroponic Systems

Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors. 1 Set Up. 1.1 Connect the Gateway

Programmable Towel Radiator Manual

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

User and Installation Instructions. Electric Auto-Fill Water Boilers EB3F, EB4F, EB6F, EB6TF IS339 ECN3539

Installation Instructions and User Guide. Thermostatic Recessed Dual Control Shower Valve. Models covered: CAS SHCVO C, COB SHCVO C, ORB SHCVO C,

Installation, Operating and Servicing Instructions

VADA - Rain2Main Automatic Rainwater Controller

WARNING DESCRIPTION PART NUMBER QTY PLUMBING, DYNATEMP DRAIN QUENCH BRACKET, THERMOSTAT DRAIN QUENCH

AP Water Filter System Installation and operating instructions

Feed Whiz INSTRUCTION MANUAL

Moisture inside the drum is due to final testing.

ASSEMBLY INSTRUCTIONS

DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe

WASHING MACHINE READ THIS MANUAL CAREFULLY TO DIAGNOSE TROUBLE CORRECTLY BEFORE OFFERING SERVICE.

SERVICE MANUAL. Ecoboiler Model range: T20 ( ) T30 ( )

USER MANUAL STAY IN BED L I G H T C L O C K

INSTALLATION AND OPERATION INSTRUCTIONS

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017

Installation & Operating Instructions

Gas Range Catalogue. Tel: +44 (0) Fax: +44 (0) Website:

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

Installation Instructions for P/N: Algas-SDI thermostat retrofit kit

User and Installation Instructions. Wall Mounted Water Boiler WMB3F/B and WMB3F/W IS435 ECN3461

Owner s Manual TABLE OF CONTENTS

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

Installation and Operation Manual

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

WHYNTER PORTABLE AIR CONDITIONER

It is essential to read this manual carefully before it is installed and used for the first time. EFL6KWH

Parasitic Cysts - Cryptosporidium and Giardia, Chemicals, Heavy Metals, Dissolved Salts, Offensive Tastes and Odours, Sediment, Dirt,

MIDAS. Installation instructions 110/220

16 OUTDOOR MISTING FAN

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

TYBOX PAC. * _rev1* User guide. Programmable thermostat for heat pumps

Parenzo Range. Basin Mixer, Bath Filler & Bath Shower Mixer. Assembly instructions

Watch the heatsava video

Installation, commissioning and servicing instructions

Wall-Mounted Planting Kit Mini

USER GUIDE Wireless room thermostat with hot water control (DHW & single zone CH)

DRAIN WATER TEMPERING INSTALL

Service Parts

Thermostatic exposed shower valve and bath/shower mixer systems Installation guide

Twin & Triple Exposed Thermostatic Shower Valve Installation & Operating Guide

Floor Standing Bath Shower Mixer. Fitting instructions. Please keep these instructions for future reference and request of replacement parts.

Transcription:

MISTING TIMER CO1709 INSTRUCTION MANUAL CO1709 MISTING Timer.indd 1

Table of Contents Technical Data...p1 Glossary...p2 Applications & Safety Instructions... p3 Connecting to the Tap... p4 Timer Control Glossary... p5 Programming the Timer - AUTO RUN... p6 Programming the Timer - Manual ON or OFF...p7 Hints & Tips... p8 Troubleshooting / Misting System Range... p9 Warranty / QR Code...Back Page CO1709 MISTING Timer.indd 2

Technical Data Tap Connection: 20mm BSP Female Hose Connection: 12mm Hose Snap-on or 20mm BSP Male Water pressures: 100kPa - 500kPa Water Temperature: Max. 40ºC Irrigation Medium: Clean Water Batteries: 2 x 1.5V AAA Alkaline Batteries (Not Supplied) Change every 12 months. 1 CO1709 MISTING Timer.indd 3

Glossary 2 1 2 3 1. Universal Tap Adaptor 2. Tap Connection 3. Union Nut 4. LCD Display 4 7 5 6 8 5. Control Keys 6. Battery Compartment 7. Clear Screw-on Cover 8. Snap-on Hose Connection Th at se is Sa Fo To be of Us aw CO1709 MISTING Timer.indd 4

Applications & Safety Instructions t r The HOLMAN Misting Timer is designed for applications where you want to turn water OFF and ON at regular intervals. The timer will run ON for a minimum of 5 seconds and OFF for a minimum of 5 seconds. The maximum OFF time is 96 hours, 59 minutes, 59 seconds and the maximum ON time is 24 hours, 59 minutes, 59 seconds. Any time in 1 second intervals can be set between these limits. Safety Instructions For reasons of long life reliability, only use good quality ALKALINE batteries. Use only clean water. To prevent the tap timer failing through weak batteries during a prolonged absence, the batteries must be replaced before re-use. The functional reliability of the tap timer depends on the functional capability of the batteries. Programme the tap timer before connecting to the water tap with the tap closed. Use the tap timer in outdoor areas only. Before the start of the frost period the tap timer must be stored away from frost and damp. The temperature of water through the tap timer must not exceed 40ºC. 3 CO1709 MISTING Timer.indd 5

Connecting to the Tap Note: Firstly program the timer to the settings you require. (See Programming on opposite page) For connection you need a water tap with a 20mm or 25mm thread. 1. Unscrew the union nut (3) to enable the water tap connection (2) to move freely. 2. Screw the tap timer firmly onto the water tap by the tap connection. Turn the unit to face you so the LCD Display (4) and Control Keys (5) can be easily seen. 3. Screw the Union Nut (3) up tight. 4. Connect your hose to the Snap-on Hose Connection (8) or unscrew the Hose Connection and screw on a misting filter or irrigation piping directly to the misting timer thread at the base of the unit. Note: Screw the connection by hand. DO NOT use a wrench. Always keep the Clear Screw-on Cover 4 (7) closed on the unit to prevent dirt from getting into the mechanism, preventing operation. T e N A ( CO1709 MISTING Timer.indd 6

Timer Controls Glossary The Misting Timer is very easy to programme: OFF Time ON Time Timer ON Manual Increase Decrease w Auto Run Note: Fit 2 x 1.5V AAA A ALKALINE Batteries (Ensure they are good quality) Reset Auto / Manual Operation Timer OFF Set Time 5 CO1709 MISTING Timer.indd 7

Programming the Timer - AUTO RUN Note: OFF & ON time is set in hours, minutes and seconds. Factory setting on power up is OFF 30 minutes & ON 3 Minutes. Programming is easy, simply scroll through the digits and adjust them up or down. When setting AUTO cycle, the LCD must show OFF. Press the ON/AUTO/OFF button until OFF is shown. STEP 1 - SET OFF TIME Next - SET ON TIME A) Push SET Button - Adjust Hours Up or Down B) Push SET Button - Adjust Minutes Up or Down C) Push SET Button - Adjust Seconds Up or Down A) Push SET Button - Adjust Hours Up or Down B) Push SET Button - Adjust Minutes Up or Down C) Push SET Button - Adjust Seconds Up or Down STEP 2 - SET TO AUTO RUN 6 Push ON / AUTO / OFF Button until AUTO shows on the LCD. The unit will start watering. Pu No - I - I - I - I f - T CO1709 MISTING Timer.indd 8

Programming the Timer - Manual ON or OFF Push ON / AUTO / OFF Button until ON or OFF shows on the LCD. TO Notes: - If in ON position the timer will stay OPEN. - If in OFF position the timer is CLOSED. n wn - If in AUTO position the timer will sequentially run OFF time & then ON time. - If you set ON or OFF time to less than 5 seconds the timer will stay ON or OFF for 5 seconds. - The timer will continue to turn ON & OFF as per the settings while in the AUTO mode. 7 CO1709 MISTING Timer.indd 9

Hints & Tips T 1. CHANGING BATTERIES - Always wait for 5 minutes after you remove the batteries & install new ones. - This allows time for the electronic circuit to RESET & CLEAR itself. - Always change batteries regularly. If using on rapid ON & OFF cycles you may need to change batteries more often. 2. RESET - The RESET Button can be used to REBOOT the electronic circuit. - This will cancel all settings. Use a paperclip or small screwdriver to push the button through the RESET hole in the timer decal. 8 T If c in C H A Is Is h CO1709 MISTING Timer.indd 10

Troubleshooting Misting System Range Troubleshooting Batteries MS20001 - Universal Misting Tap Adaptor (Qty x 1) MS20002 - Misting Tee (Qty x 2) If battery power becomes low, the valve MS20003 - Misting Elbow (Qty x 2) closes automatically. In this case please MS20004 - Threaded Misting Tee with Jet (Qty x 2) insert new ALKALINE batteries. MS20005 - Threaded Misting Elbow with Jet (Qty x 2) MS20006 - Mounting Clip with Masonry Nail (Qty x 10) MS20007 - Misting Tube (5 Metres Flexible PVC) MS20008 - Misting Tube Lengths 60cm (Qty x 5) MS20009 - Brass & Stainless Steel Misting Jets (Qty x 5) MS20010 - Brass Anti-Drain Valve (Qty x 1) MS20011 - Plastic Misting Tube Cutter (Qty x 1) MS20012 - Misting Filter (Qty x 1) Checking Functionality Faults Have batteries been correctly inserted? Are the batteries flat? Is the water tap open? Is the program data correct? has the unit been set to Manual OFF? MK21013 - Misting System (Comprehensive Pack) MK21014 - Misting System (Expansion Kit) 9 CO1709 MISTING Timer.indd 11

Warranty Warranty: We will honour all statutory guarantees that this product is of acceptable quality. (including that it is fi t for purpose) HOLMAN Industries: 47 Walters Drive, Osborne Park, WA 6017. Ph: +61 8 9204 1011 www.holmanindustries.com.au Scan the QR Code above to see more information on the Misting System - including a product guide video. CO1709 MISTING Timer.indd 12