MIST SYSTEM CONFIGURATION AND PROGRAMMING INSTRUCTIONS R03

Similar documents
20 Series INSTALLATION MANUAL ENG-R00

E7/2 and E8 Chambers. Installation Manual ENG R00

Conviron CMP5090 User Guide

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

LaserFOCUS VLF-250 Engineering Specification

Intelligent Security & Fire Ltd

Knight Trak II Instruction Manual

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Reach-In. PLanT GROWTh. Reach-In

DC200 Digital Dispenser Operating Manual

EXPERT TRI-STAR. Temperature controller. User s Manual

aura-t TP536/EU ventilation systems

aura-t TP536/GBR ventilation systems

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Factory Packaged Controls. MHGRV-X Controller Field Technical Guide

4-PGM Expansion Module

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

Open-area Smoke Imaging Detector. Engineering Specification

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

8-zone Expansion Module

Moxa Proactive Monitoring User s Manual

Surveyor Excel. Fire Alarm Control Equipment Network version. Programming Manual MASTER MANUAL. VERSION 14.0 and Above

Dehumidifying Dryers DP DP 615 Series

Faster Temperature (& Humidity) Chamber

C-Bus 2 Channel Bus Coupler with Remote LED Facility Installation Instructions

ID50series. intelligent fire alarm panels

EBC20. Instructions for fitting, installation and operation. Read and save these instructions!

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

C2 Compact Range Installation & Programming Manual

Xtralis VESDA LCD Programmer Quick Reference Guide

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

See the table on the following Page for full descriptions of each Pin Type.

BDR16 User Manual ENG R00

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

edwardsvacuum.com VACUUM PUMPS EOSi ROTARY SCREW PUMP

SWITCHLITE MRE DDM ADJ

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)

Spa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert)

A2000 Chamber INSTALLATION, OPERATION, AND MAINTENANCE MANUAL ENG R01

ED-18 Analog Output Series Magnetic Encoder SPECIFICATIONS

Control/Communicator Installation Manual

LC-3DPRINT BOX. Instruction For Use. LC-3DPrint Box

Incutrol/2 Regulator

Operating Display SCREENS

Quick start guide. BiPAP AVAPS

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

/18 (JRK) MTD User Manual OJ Electronics A/S

Programmable Interactive User Manual

C - B u s C - T o u c h U s e r s G u i d e C T Series

TRAULSEN TECHNICAL BULLETIN

HARDWIRED CONTROL PANELS

intelligent fire alarm ID60series panels

MWS3A-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

STT700 Temperature Transmitter Lightning Protection Device Specifications 34-TT-03-20, June 2017

GTC15 Temperature Controller Operation Manual

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

E Wired Intruder Detector

Quick start guide. English

Quick start guide. BiPAP AVAPS

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

C-Bus PIR Occupancy Sensor. Installation Instructions 5751L

Sensor Control Panel

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

MPT Electric Fire Pump Controller

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

CC408. Quick Reference Guide Solution 880

Operator's Handbook. Interactive Fire Alarm System Release 3. Information Panel, BV-320. Protecting life, environment and property...

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

F series. echoflex. Slim Line Dimming Controller. Product Overview ER1S-FC

Ceiling Microwave presence/absence detector 12-24V AC/DC

T8000 Series T8600 MODBUS Touch Screen Thermostat

Version 1.03 January-2002 USER S MANUAL

ST3124. KNX Blind Actuator DC 4-fold. Operation and Installation Manual

PRODUCT BULLETIN. Rev. A Monitoring Station offering PN Rev. B as a direct replacement. OVERVIEW / DESCRIPTION

AQUATROL Zone Synchronizing Universal Injection/Mixing Boiler Reset Controls AQ252

DOG2 MEMS SERIES CAN J1939 INCLINOMETER

TEC210x-2 Series Networked Thermostats

F series. Complete Room Controller. echoflex Powered by ETC. Product Overview ERDRC-FC

T5000 T5000 LCD Digital Fan Coil Thermostat--More Models

Dryer Controller M720

Compact Ultra Low Temperature Chamber

Heart icon. Model designation Run icon. Low battery icon Start/Stop button

STT 3000 Series STT250 /150 Surge Protection Device Specifications

User manual and installation guide

Algo-Tec 6500/6600 INTERACTIVE ADDRESSABLE FIRE CONTROL SYSTEM

MTC User Manual

CELLTROL II BIOREACTOR CONTROL SYSTEM OPERATIONS MANUAL

Touchpad Exit Controller User Guide

Electro-Sentry. Users Manual

Summit 3208GLD USER MANUAL. Electronics Line

Protégé EliteSuite Eclipse LED Keypad Installation Manual ELT-KLES

Quick Programmer s Manual

CATALOGUE. Request to Exit Products Relays, Fuses & Timers TROJAN DEVELOPMENTS Product Catalogue.

SERIES 3000 INTELLIGENT FIRE ALARM CONTROL PANEL ENGINEERING PROGRAMING MANUAL TABLE OF CONTENTS.. 1 INTRODUCTION.. 3 SYSTEM POWER UP.

UEZ 2000/1 LSN, UEZ 2000 LSN, Intrusion Control Centers

BTC15 Temperature Controller Operation Manual

ReFreeX H426V1 User manual

RADIANT HEATING AND COOLING SYSTEMS CLIMATE CŎNTROL ZONING SYSTEM INSTALLATION GUIDE. Climate Cŏntrol Zoning System Installation Guide

Transcription:

MIST SYSTEM CONFIGURATION AND PROGRAMMING INSTRUCTIONS 261134R03

MIST SYSTEM CONFIGURATION AND PROGRAMMING INSTRUCTIONS PLEASE READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE OPERATING. Published by: CONVIRON 590 Berry Street Winnipeg, Manitoba Canada R3H 0R9 www.conviron.com November 2017 2017 Controlled Environments Limited. Conviron is a registered trademark of Controlled Environments Limited. All other trademarks are the property of their respective owners. Information subject to change without written notice.

CONVIRON SERVICE AND TECHNICAL SUPPORT For additional support, please contact us directly. Head office Technical Services Conviron 590 Berry St. Winnipeg, Manitoba, Canada R3H 0R9 Conviron Technical Services North America Europe Toll free +1.800.363.6451 +44.(0).800.032.6422 Telephone +1.204.786.6451 +44.(0).1638.781.731 Fax +1.204.786.7736 +44.1638.741.112 Email info@conviron.com service@conviron.eu November 2017 261134R03 5

1.0 Precautions These precautions should be read and understood before proceeding with configuration. Accessing the 700-HX Key Protection switch may require access to the main electrical Control Panel. The Control Panel contains high voltage equipment, and should only be accessed by persons with appropriate electrical knowledge. November 2017 261134R03 7

2.0 Misting Timer Configuration and Programming Instructions The 700-HX Relay Timer is used in conjunction with the CMP6050 to control timing for misting events. Its operation is controlled by misting system Aux output set points entered into programs in the CMP6050 controller. When configured as indicated in these instructions, it provides two settable timers: One timer to indicate the amount of time per cycle for the misting system to be on (Set 2) during the misting period One timer to indicate the amount of time per cycle for the misting system to be off (Set 1) during the misting period When the CMP6050 Aux output corresponding to the misting system is 0001 (on), it will trigger the 700-HX to begin counting down on and off timers in a continuous loop until the end of the misting period, which occurs when the misting system Aux output set point is 0000 (off). 2.1 Misting Cycle Timing Diagram Below is an example timing diagram indicating how the misting system functions. The misting period begins at 4:00 and ends at 20:00. Misting on time is 1800s (30min) and off time is 5400s (90min). Start of Misting Period ON Time = Set 2 OFF Time = Set 1 One Mist Cycle End of Misting Period Misting Duty Cycle ON OFF CMP6050: Misting system Aux output value 0001 0000 Time 00:00 12:00 24:00 November 2017 261134R03 9

2.2 Timer Overview 1 2 3 4 5 TIMER 700-HX 12:34m s OUT RST SET 1 2 12:34 h MODE A B C D h m s 7 8 9 10 6 RST 11 12 1 - Key Protection Indiator 5 - Mode Key 9 - Set Value (Sub) Display 2 - Control Output Indicator 6 - Reset Key 10 - Up Keys A-D 3 - Reset Indicator 7 - Present Value (Main) Display 11 - Down Keys A-D 4 - Set Value 1, 2 Indicator 8 - Time Unit Indicators 12 - Key Protection Switch 10 November 2017 261134R03

2.3 Factory Settings Only: Configuring the Timer for Operation 1. Ensure Key Protection switch is in the OFF position. Switch is located on top of the timer relay. Access to control panel may be required. 2. Set timer as Twin Timer. Switch to Function Mode (press and hold the Mode and the Up portion of the D key for one second, release both keys when Mode changes). Function mode will show a FUnC in red on the top section of the display and in green on the lower right section of the screen either twn, for the twin timer mode or tim, for the regular timing mode. Use the D key to set the timer to twn. Press and hold Mode and the Up portion of the D key to return to Run Mode. 3. Set parameters for the twin timer in Function Setting Mode. To switch to Function Setting Mode from Run Mode, press and hold the Mode key for three seconds and oftr should appear in red on the upper section of the display. This indicates Function Setting Mode is active. 4. Set Off Time Range (oftr). This is the amount of time the misting system will be off. Use the D key to select ----s. This allows the user to set each timer over a range of 1-9999 seconds. Other ranges can be chosen by user if needed. Press the Mode key to move to the next configurable parameter. 5. Set On Time Range (ontr). This is the amount of time the misting system will be on. Use the D key to select ----s. This allows the user to set each timer over a range of 1-9999 seconds. Other ranges can be chosen by user if needed. Press the Mode key to move to the next configurable parameter. 6. Set Timer Mode (timm). Down = timer will count down remaining time. Up = timer will count elapsed time. Use the D key to select down. This will ensure a user can always determine the remaining time for the active timer. Press the Mode key to continue to the next configurable parameter. 7. Set Timer Output Mode (totm). Indicates whether counting will begin with the off or on timer. Use the D key to select ton. This will ensure each misting period begins with the misting system on. Press the Mode key to continue to the next configurable parameter. 8. Set Input Signal Width (iflt). Use the D key to select to select 20nS. Press the Mode key to continue to the next configurable parameter. 9. Set upper limit for Set 1 (SL1H) and Set 2 (SL2H) timers. This sets the maximum value for Set 1 or Set 2 timers. Using the A-D Up/Down keys, set the values for SL1H and SL2H to 9999. 10. Set Key Protect Level (kypt). This allows the user to disable certain keys on the front panel of the timer. Use the D key to select KP-2. This will allow a user to modify the time for both on and off timers, but will lock all other buttons to avoid unwanted changes. 11. Set On Count Alarm to 0 (on-a). On Count Alarm (on-a) and on On Count Alarm Monitor (on-c) functionality are not used. 12. Press and hold the Mode key for three seconds. This will exit Function Setting Mode and return to Run Mode. 13. Slide Key Protection Switch to ON. The 700-HX Timer relay is now ready for operation. November 2017 261134R03 11

2.4 Client Settings: Programming the Misting System Once the timer is configured for operation, values for Set 2 (misting on time) and Set 1 (misting off time) can be entered at the timer, and timelines defining the beginning and end of the misting period can be programmed in the CMP6050 controller. 1. Set misting system on time (Set 2). Press the Mode key to toggle between Set 1 and Set 2. Use the A-D Up and Down keys to input misting on time. 2. Set misting system off time (Set 1). Press the Mode key to toggle between Set 1 and Set 2. Use the A-D Up and Down keys to input misting off time. 3. Create or open an existing program. At the CMP6050 interface, navigate to or create a program in which you want misting to occur (See the CMP6050 Operator s Manual for more information on creating and editing programs). 4. Create a timeline and input the desired misting system start time. In the misting system Aux ouput column for that timeline, input 0001 as the set point (see below). 5. Create a timeline and input the desired misting system stop time. In the misting system Aux output column for that timeline, input 0000 as the set point. 6. Save changes to the program. Mist system Aux output Aux number may change depending on chamber configuration Mist system ON Mist system OFF 12 November 2017 261134R03

Conviron - Head Office Winnipeg, Canada conviron.com Conviron - US Pembina, USA conviron.com Conviron Europe Ltd. Cambridgeshire, UK conviron.co.uk Conviron GmbH Berlin, Germany conviron.de Conviron - China Shanghai, China conviron.cn Conviron - Australia Melbourne, Australia conviron.com.au www.conviron.com info@conviron.com

Management System Certified to ISO 9001 261134R01 Nov 2017 2016 Controlled Environments Limited. Conviron is a registered trademark of Controlled Environments Limited. All other trademarks are the property of their respective owners. Information subject to change without written notice.