Gage Unamplified Noncompensated Flow-Through

Similar documents
Pressure Sensors: Measurement Type: Gage, Vacuum Gage; Signal Conditioning: Unamplified; Pressure Range: ± 15.0 psi; Port Style: Straight

Interactive Catalog Replaces Catalog Pages

Interactive Catalog Replaces Catalog Pages

zu verkaufen: 54 Stück Honeywell Drucksensoren 143PC03D neu, und in Originalverpackung Preis: Euro per Stück

Miniature Low Pressure Sensors. 24PC Series, Uncompensated/Unamplified 0.5 psi to 250 psi. Datasheet

Miniature Low Pressure Flow-Through Sensors. 26PC Series, Compensated/Unamplified 1 psi to 100 psi. Datasheet

MSP100 Pressure Transducer

DP86 Constant Voltage with Fitting

MSP100 Pressure Transducer

MS1471 SPECIFICATIONS. PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost

Basic Board Mount Pressure Sensors. NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi] Datasheet

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi]

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Standard SPECIFICATIONS FEATURES APPLICATIONS

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 1 Bar to 10 Bar [15 psi to 150 psi]

Issue C. Installation Instructions for the Basic Amplified Board Mount Pressure Sensors, ABP Series

85 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

MS4525DO SPECIFICATIONS FEATURES APPLICATIONS

FSS-SMT Series. Low Profile Force Sensor

Installation Instructions for the MicroPressure Board Mount Pressure Sensors MPR Series Compact, High Accuracy, Compensated/Amplified

SSC Series Standard Accuracy Plastic Silicon Pressure Sensors ±2 % Total Error Band, Digital Output, SMT and DIP, 1 psi to 150 psi

82 Constant Voltage SPECIFICATIONS. 316L SS Pressure Sensor 19mm Diameter Package 0-100mV Output Absolute and Gage Temperature Compensated

MSP340 Pressure Transducer

MS4525 SPECIFICATIONS

Installation Instructions for the Honeywell Force Sensors FSA Series Compensated/Amplified

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

86BSD Digital Output

Force Sensors Line Guide

Interactive Catalog Replaces Catalog Pages

154BC SPECIFICATIONS. Please refer to the 154N uncompensated and constant voltage datasheets for more information on different features of the 154.

D5100 Industrial Differential Pressure Transducer

Sub psi SPECIFICATIONS

Board Mount Pressure Sensors Line Guide

D5100 Industrial Differential Pressure Transducer

M7100 Pressure Transducer

Product Training Module: Honeywell TruStability Board Mount Pressure Sensors: Uncompensated/Unamplified NSC Series

Selecting Honeywell Board Mount Pressure Sensors

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Model Super TJE. Ultra Precision Pressure Transducer DESCRIPTION FEATURES

MSP300 Pressure Transducer

86BSD Digital Output

19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control

154BC SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

Honeywell Zephyr Analog Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

Model A-5. Low Range Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES

86BSD Digital Output

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM. Datasheet

U5300 Industrial Pressure Transducer

M5800 Pressure Transducer with Rotatable Display

WARNING MISUSE OF DOCUMENTATION

SX Series Silicon Pressure Sensors 0 psi to 1 psi to 0 psi to 150 psi

Installation Instructions for the

M5200 Industrial Pressure Transducer

Airflow Sensors Line Guide

85 Uncompensated SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage

M5800 Pressure Transducer with Rotatable Display

Airflow Sensors Line Guide

Model HL-Z. High Line Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES POTENTIAL APPLICATIONS

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:

Honeywell Zephyr Digital Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

MEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Oil & Gas. Features:

86A SPECIFICATIONS. 316L SS Pressure Sensor Small Profile V High Level Output Gage, Absolute ASIC Calibrated

U5700 Submersible Liquid Level Pressure Transducer

TruStability Board Mount Pressure Sensors

PRODUCT TRAINING MODULE: Honeywell Zephyr Airflow Sensors HAF Series High Accuracy

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6120/6121 Series

Product Training Module: Basic Board Mount Pressure Sensors Uncompensated/Unamplified NBP Series

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

Model 424. Wing Union/Hammer Union Pressure Sensors DESCRIPTION POTENTIAL APPLICATIONS FEATURES

U5600. Wireless Pressure Transducer SPECIFICATIONS

Honeywell Zephyr Digital Airflow Sensors: HAF Series High Accuracy 20 SLPM or 200 SLPM

Heavy Duty Pressure Transducers

FC22 Compression Load Cell

Heavy Duty Pressure Transducers Line Guide

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6130/6131 Series with SPI Communication

89BSD Digital Output

HIH-4030/31 Series Humidity Sensors

Honeywell HumidIcon Digital Humidity/Temperature Sensors. HIH6100 Series ±4.0 %RH Accuracy. Datasheet

HIH-4010/4020/4021 Series Humidity Sensors

SPECIFICATIONS. SENSOR SOLUTIONS ///LM Page 1 09/2015

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

MEMS Pressure Sensor Solutions

Pressure Transducers Ultrahigh-Purity

SUBMERSIBLE Flush Diaphragm Liquid Level Sensor AST4520

Modus Model DA General Eastern Low Differential Pressure Alarm Controller

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

LOW PRESSURE Intrinsically Safe Transducer AST44LP

HIH-5030/5031 Series Low Voltage Humidity Sensors

HIH-4000 Series Humidity Sensors

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4400

Analog Room Pressure Monitor RPC Series

Issue C CAUTION

Sensors in Ventilators

FC23 Compression Load Cell

Honeywell HumidIcon Digital Humidity/Temperature Sensors. HIH9000 Series ±1.7 %RH Accuracy. Datasheet

Transcription:

Gage Unamplified Noncompensated Flow-Through FEATURES Measures positive and negative gage pressures Flow-through port design fits in-line with application Popular port sizes: - 8 mm (.315 in.) OD (1/4 in. ID tubing or standard connectors) - 0.144 in. OD (1/8 in. ID tubing) 24PC Series Medical grade ISO 10993-1 (USP Class 6) port material Silicon sensor chip 24 inch wire harness with splash proof connector Minimal deadspace efficient cleansing and disinfecting 24PC SERIES PERFORMANCE CHARACTERISTICS at 10.0 ±0.01 VDC EXCITATION, 25 C Min. Typ. Max. Units Excitation --- 10 12 VDC Null Shift, 25 to 0, 25 to 50 C --- ±2.0 --- mv Null Offset 30 0 +30 mv Linearity, P2 > P1, BFSL --- ±0.5 --- %Span Span Shift, 25 to 0, 25 to 50 C --- ±5.0 --- %Span Repeatability & Hysteresis --- ±0.2 --- %Span Response Time --- --- 1.0 msec Input Resistance 4.0 K 5.0 K 6.0 K ohms Output Resistance 4.0 K 5.0 K 6.0 K ohms Stability over One Year --- ±0.5 --- %Span Unamplified ENVIRONMENTAL SPECIFICATIONS Operating Temperature Storage Temperature Shock Vibration Media Compatibility 40 to +85 C ( 40 to +185 F) 55 to +100 C ( 67 to +212 F) Qualification tested to 150 g Qualification tested to 0 to 2 khz, 20 g sine Limited only to those media which will not attack polysulfone, silicon, fluorosilicone, silicone, EPDM, and neoprene seals 24PC SERIES FLOW THROUGH ORDER GUIDE Pressure Sensitivity Catalog Range Span, mv mv/psi Overpressure Listing psi Min. Typ. Max. Typ. psi Max. 24PCE Type 0.5 25 35 45 70 20 24PCA Type 1.0 30 45 60 45 20 24PCB Type 5.0 85 115 145 23 20 24PCC Type 15 165 225 285 15 45 24PCD Type 30 240 330 420 11 60 24PCF Type 100 156 225 294 2.25 200 24PCG Type 250 145 212 280 0.85 500 Honeywell MICRO SWITCH Sensing and Control 1-800-537-6945 USA 1-815-235-6847 International 1-800-737-3360 Canada 21

Gage Unamplified Noncompensated Flow-Through 24PC Series SENSOR SELECTION GUIDE 2 4 PC A F* N 5 G Product Circuit Pressure Pressure Type of Port Termination Pressure Family Type Transducer Range Seal Type Style Measurement 2 20PC Family 4 Noncompensated A 1 psi B 5 psi C 15 psi D 30 psi E 0.5 psi F 100 psi G 250 psi E EPDM F Fluorosilicone N Neoprene S Silicone G Small N Large (.350 dia.) P Large (.315 dia.) 2 4-pin DIP 5 Wire harness 6 4-pin SIP Example: 24PCBFG5G Non-compensated 5 psi sensor, fluorosilicone seal, small flow-through ports, wire harness, and gage pressure measurement. *Other media seal materials may be available. Note: Not all combinations are established. Contact 800 number before final design. See Accessory Guide, page 27. G Gage 22 Honeywell MICRO SWITCH Sensing and Control 1-800-537-6945 USA 1-815-235-6847 International 1-800-737-3360 Canada

Gage Unamplified Compensated Flow-Through FEATURES Measure positive and negative gage pressures Flow-through port design fits in-line with application Popular port sizes: - 8 mm (.315 in.) OD (1/4 in. ID tubing or standard connectors) - 0.144 in. OD (1/8 in. ID tubing) 26PC Series Medical grade ISO 10993-1 (USP Class 6) port material Silicon sensor chip 24 inch wire harness with splash proof connector Minimal deadspace efficient cleansing and disinfecting 26PC SERIES PERFORMANCE CHARACTERISTICS at 10.0 ±0.01 VDC Excitation, 25 C Min. Typ. Max. Units Excitation --- 10 16 VDC Repeatability & Hysteresis --- ±0.20 --- %Span Response Time --- --- 1.0 msec Input Resistance 5.5 K 7.5 K 11.5 K ohms Output Resistance 1.5 K 2.5 K 3.0 K ohms Stability over One Year --- ±0.5 --- %Span Weight --- 2 --- grams Total error calculation, see page 105. Unamplified ENVIRONMENTAL SPECIFICATIONS Operating Temperature Storage Temperature Compensated Temperature Shock Vibration Media (P1 & P2) 40 to 85 C ( 40 to +185 F) 55 to +100 C ( 67 to +212 F) 0 to +50 C (32 to +122 F) Qualification tested to 150 g MIL-STD-202. Method 213 (150g halfsine, 11 msec) Limited only to those media which will not attack polyetherimide, silicon, fluorosilicone, silicone, EPDM, and neoprene seals. 26PC SERIES ORDER GUIDE Pressure Over- Catalog Range Linearity Null Shift Null Offset Span Shift Span Sensitivity pressure Listing (psi) (% span) (mv) (mv) (% span) (mv) mv/psi psi Typ. Max Typ. Max Min. Typ. Max. Typ. Max. Min. Typ. Max. Typ. Max. 26PCA TYPE 1 0.25 0.5 ±0.5 ±1.0 1.5 0 +1.5 ±1.0 ±2.0 14.7 16.7 18.7 16.7 20 26PCB TYPE 5 0.4 0.5 ±0.5 ±1.0 1.5 0 +1.5 ±1.0 ±1.5 47 50 53 10.0 20 26PCC TYPE 15 0.25 0.5 ±0.5 ±1.0 1.5 0 +1.5 ±0.75 ±1.5 97 100 103 6.67 45 26PCD TYPE 30 0.1 0.2 ±0.75 ±1.5 1.5 0 +1.5 ±0.75 ±1.5 97 100 103 3.33 60 26PCF TYPE 100 0.1 0.2 ±1.0 ±2.0 2.0 0 +2.0 ±0.5 ±1.5 95 100 105 1.0 200 26PCJ TYPE 38* 0.1 0.5 ±0.7 ±1.5 1.5 0 +1.5 ±1.0 ±1.5 37.5 39.5 41.5 2.63 60 26PCK TYPE 38* 0.1 0.5 ±0.7 ±1.5 1.5 0 +1.5 ±1.0 ±1.5 37.5 39.5 41.5 2.63 60 *Accuracy specifications calculated at 15 psi. Honeywell MICRO SWITCH Sensing and Control 1-800-537-6945 USA 1-815-235-6847 International 1-800-737-3360 Canada 23

Gage Unamplified Compensated Flow-Through 26PC Series SENSOR SELECTION GUIDE 2 6 PC A F* N 5 G Product Circuit Pressure Pressure Type of Port Termination Pressure Family Type Transducer Range Seal Type Style Measurement 2 20PC Family 6 Compensated, Calibrated A 1 psi B 5 psi C 15 psi D 30 psi F 100 psi J 38 psi K 38 psi (passivated) E EPDM F Fluorosilicone N Neoprene S Silicone G Small N Large (.350 dia.) P Large (.315 dia.) 2 4-pin DIP 5 Wire harness 6 4-pin SIP Example: 26PCBFG5G Compensated, calibrated 5 psi sensor, fluorosilicone seal, small flow-through ports, wire harness, and gage pressure measurements. *Other media seal materials may be available. Note: Not all combinations are established. Contact 800 number before final design. See Accessory Guide, page 27. G Gage 24 Honeywell MICRO SWITCH Sensing and Control 1-800-537-6945 USA 1-815-235-6847 International 1-800-737-3360 Canada

Gage Unamplified Flow-Through MOUNTING DIMENSIONS (for reference only) Large Port Sensor N 24/26PC Series 20PC CIRCUIT NOTES 1. Circled numbers refer to Sensor Terminals (interface pins). 2. V 0 increases with pressure change. 3. V 0 V 2 V 4 PIN DESIGNATION Pin 1 V s (Red) Pin 2 Output, + (White) Pin 3 Ground, (Black) Pin 4 Output, (Green) EXCITATION Unamplified Large Port Sensor P Flow-Through Construction NOTE: Wire harness (PC-15175) may be purchased separately. Honeywell MICRO SWITCH Sensing and Control 1-800-537-6945 USA 1-815-235-6847 International 1-800-737-3360 Canada 25

Gage/Unamplified Flow-Through 24/26PC Series MOUNTING DIMENSIONS (for reference only) Small Port Sensor (1 x 4) Small Port Sensor (2 x 2) Small Port Sensor (G) 26 Honeywell MICRO SWITCH Sensing and Control 1-800-537-6945 USA 1-815-235-6847 International 1-800-737-3360 Canada

Accessories 22/24/26PC Series ACCESSORIES SELECTION GUIDE Catalog Listing Description Drawing PC-10182 Steel lockring (included with Port Style A, 1 x 4 terminals only) 22, 24, 26PC only Figure 1 PC-15111 Cable retaining clip for large port Flow-Through sensor only Figure 4 PC-15110 Single hole plastic bracket Figure 3 PC-15015 Mounting bracket Figure 6 PC-15132 Plastic Mounting bracket Figure 5 20PCWHRC Flow-Through wire harness and retaining clip Figure 2 26PCBKT Mounting bracket for large port Flow-Through sensor only Figure 7 PC-15202 Mounting bracket for Luer Port Figure 8 PC-15204 Mounting bracket for Straight Port Figure 9 Unamplified Figure 1 PC-10182 Steel Lockring Figure 2 20PCWHRC Wire Harness and Retaining Clip Figure 3 PC-15110 Single Hole Plastic Bracket Figure 4 PC-15111 Cable Retaining Clip Figure 5 PC-15132 Plastic Mounting Bracket Honeywell MICRO SWITCH Sensing and Control 1-800-537-6945 USA 1-815-235-6847 International 1-800-737-3360 Canada 27

Accessories 22/24/26PC Series Figure 6 PC-15015 Mounting Bracket Figure 7 26PCBKT For use with N, P Large Ports Figure 8 PC-15202 For use with C Luer Port Figure 9 PC-15204 For use with A Straight Port Note: PC-15202 and PC-15204 are Printed Circuit Board mountable and solderable; designed to be used in a.063 thick PC Board with a recommended mounting hole size of.125 ±.005 in. 28 Honeywell MICRO SWITCH Sensing and Control 1-800-537-6945 USA 1-815-235-6847 International 1-800-737-3360 Canada