RVL471. Heating controller. G2524en. Installation Instructions. 1 Installation. 2 Commissioning

District heating controller for two heating circuits and d.h.w. according to Siemens specifications:

RVL47. Heating Controller. Installations Instructions. Installation

RVP331. Heating Controller for 2 heating circuits, d.h.w. and boiler. Building Technologies HVAC Products

RVP310. Heating Controller. Building Technologies HVAC Products

Heating Controller for 2 heating circuits, d.h.w. and boiler, communicating

RVL470. Heating Controller. Use. Functions. Series B

RVL471 Heating and Domestic Hot Water Controller Basic Documentation

G2484. Installation. - Control panel (in the panel front, on the inner wall, or on a DIN rail)

RVP360 and RVP361 Heating controllers for 2 heating circuits and d.h.w. Basic Documentation

RVL472. Heating Controller. Building Technologies HVAC Products. Series C. including d.h.w. heating

Use. Functions. Key function. Other functions

Heating and D.h.w. Controller RVL482 Basic Documentation

Operating Instructions

RVP340 Heating controller for 1 heating circuit RVP350 and RVP351 Heating controllers for 1 heating circuit and d.h.w. Basic Documentation

RVL481. Heating Controller. including d.h.w. heating

Operating Instructions Heating Controllers RVL479, RVL480, RVL481, RVL482

RVL480. Heating Controller

RVA Heating Circuit or Primary Controller Basic Documentation. Siemens Building Technologies Landis & Staefa Division

ProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data.

RVL479. Heating Controller. for use with a partner unit

RVD120, RVD140 Controllers for district heating and d.h.w. Basic Documentation

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER

Operating Instructions

RVA Cascade Controller for modulating gas-fired Boilers Basic Documentation

QAA Room Unit for Boiler Control with OpenTherm Interface Basic Documentation. Siemens Building Technologies Landis & Staefa Division

ProCon 16, 31, 47, 75, 77 & HT. RVA 46. Zone Controller Commissioning Data.

District heating controller

PRELIMINARY EDITION

District heating controller

QAW70. Room Unit. Siemens Building Technologies HVAC Products. for use with heating controllers

District Heating Controller

REA22 Room Temperature Controller

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

Self-learning Room Temperature Controller

QAW70. Room Unit. Building Technologies. for use with heating controllers

P20. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort P20. User's Guide. Installer's Guide *VI7BD502* *087R8014* *087R8014* *VI7BD502*

Installation, service and operating instruction Cetetherm Midi Compact SR144 DHWC

ProCon Boiler Controller Commissioning Quick Reference Guide

RVS13... RVS53... AVS75... AVS37... QAA75... QAA78... QAA55... Albatros2 Boiler controllers User Manual. Building Technologies HVAC Products

M116 / M450 USER AND MAINTENANCE MANUAL FOR MODULATING-CONTROL BOILER WITH GAS BURNER EQUIPPED FOR NATURAL GAS. Type : B23 ATLANTIC 2000

C37. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C37. User's Guide. Installer's Guide *VI7CE602* *087R8070* *087R8070* *VI7CE602*

RVS46.. AVS75.. AVS37.. QAA75.. QAA78.. QAA55.. Albatros 2 Zone controller User Manual. Building Technologies HVAC Products

Main Features. Functions. with automatic ignition and control functions for the heating and domestic hot water circuit

Type summary Albatros 2

Room Unit for Boiler Control QAA User manual. Building Technologies. With OpenTherm Interface

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

RVS43.. RVS63.. AVS75.. AVS37.. QAA75.. QAA78.. QAA55.. Albatros2 Boiler controllers User manual. Building Technologies HVAC Products

Room thermostat with Auto Timer, independent DHW

Albatros2 Boiler Controllers User Manual RVS13.. RVS53.. Siemens Schweiz AG HVAC Products. Edition 1.0 Controller series A CE1P2383en

Room Units and Sensors for Use in Heating Plants. Siemens Building Technologies HVAC Products SIGMAGYR. Type summary

C66. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C66. User's Guide. Installer's Guide. *vi7cc502* *087R8069* *087R8069* *vi7cc502*

INSTRUCTION FOR THE USER THC V E OIL BLU

Local Process Bus LPB

Operating Instructions

Heating Controller. Building Technologies HVAC Products. Synco 700

Weather compensated flow temperature control of heating and boiler systems

1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS...

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

ECL Comfort 110, application 130

RVS43.. RVS63.. AVS75.. AVS37.. QAA75.. QAA78.. QAA55.. Albatros2 Boiler controller User Manual. Building Technologies HVAC Products

Heating Controller SDC. District Heating Controller DHC 43 OPERATING INSTRUCTIONS

MC200. Users Instructions. HEATING DIVISION Hort Bridge Ilminster, Somerset TA19 9PS Tel: Fax:

ECL Comfort 110, application 116

C62. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C62. User's Guide. Installer's Guide *VIKME102* *087R8091* *087R8091* *VIKME102*

Roth Touchline. German quality since Quick and easy user manual 1/10

Operating instructions

BLC1.A Boiler Load Compensator

Room Unit. Building Technologies SYNERGYR

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys

Albatros 2 Solar compact controller User manual RVA Building Technologies

ECL Comfort V a.c. and 24 V a.c.

Heating Controller. Synco 700

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark

Installation Guide. ECL Comfort 210, application A Table of Contents

prestige Control Application Supplement - ACVMax

prestige Control Application Supplement WARNING

Self-learning Room Temperature Controller

The ECL Comfort 110 is a universal 1-circuit controller for use in district heating substations and district heating systems as well as boilerbased

Control Application. Supplement - ACVMax

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

Roth Touchline. German quality since User manual quick and easy guide 1/10

- Data Brochure Universal Reset Module 422

1. COMMISSIONING OF THE BOILER en DESCRIPTION FUNCTION BUTTON DESCRIPTION SYMBOL DISPLAY

prestige Control Application Supplement - TriMax

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button

Semi flush-mount room thermostats

Condensing Boiler RS100 Controller Training Program

Grant Aerona³. Air to Water High Efficiency Heat Pump Range. User Instructions

Service Instructions for use by heating contractor

Self-learning Room Temperature Controller

Technical Data Manual

Self-learning Room Temperature Controller

Albatros 2 CHP Controller User Manual OEM. RVC32.4x0. Building Technologies HVAC Products

Operating instructions

Immersion Temperature Controller

Heating Controller SDC Remote Heating Controller DHC

ECL Comfort V a.c. and 24 V a.c.

- Data Brochure Steam Control 279

BM Programming Module. For the heating engineer Installation instructions

Transcription:

G2474 74 319 0081 0 a en Installation Instructions Heating controllers RVP3... Installation Place of installation In a dry room, e.g. in the boiler room Mounting choices: Control cabinet (in the front, on the inner wall, or on a DIN rail) Control panel In the sloping front of a control desk Permissible ambient temperature: 0...50 C Electrical installation The local regulations for electrical installations must be complied with Cable tension relief must be ensured The cables from the controller to the actuators and pumps carry mains voltage The cables to the sensors should not be run parallel to mains carrying cable Permissible cable lengths For all sensors, thermostats and external contacts: Copper cable 0.6 mm dia. max. 20 m Copper cable 1.0 mm 2 max. 80 m Copper cable 1.5 mm 2 max. 120 m For room units: Copper cable 0.25 mm 2 max. 25 m Copper cable 0.5 mm 2 max. 50 m For the data bus: 0.75...2.5 mm 2 refer to the specifications contained in data sheets N2030E and N2032E Mounting and wiring the base Wall mounting 1. Separate base from the controller. 2. Hold base against the wall. Marking «TOP» must be at the top! 3. Mark fixing holes on the wall. 4. Drill holes. 5. If required, knock out holes on the base for cable entry glands. 6. Screw base to the wall. 7. Wire up base. DIN rail mounting 1. Fit rail. 2. Separate base from the controller. 3. If required, knock out holes on the base for cable entry glands. 4. Fit base to the rail. Marking «TOP» must be at the top! 5. If required, secure base (depending on the type of rail used). 6. Wire up base. Flush panel mounting Required panel cutout: 92 x 138 mm Maximum thickness: 3 mm 1. Separate base from the controller. 2. If required, knock out holes on the base for cable entry glands. 3. Insert base in the panel cutout from behind until stop is reached. Marking «TOP» must be at the top! 4. Push lateral tongues behind the front panel (refer to illustration below). 5. Wire up base. Make sure the cable lengths are such that there is sufficient space to open the control panel door. Wrong Correct Place tongues on both sides correctly they may not be located inside the cutout! Commissioning Preparatory checks 1. DO NOT switch on power yet. 2. Check wiring according to the plant connection diagram. 3. Ensure correct position and location of the levers by turning the fixing screws (refer to illustration on the lateral wall of the unit): 4. Insert controller in the base until stop is reached. Marking «TOP» must be at the top! 5. Tighten fixing screws alternately. 6. Check the motorized valve: see if it is correctly installed (observe direction of flow indicated on the valve body) in the case of a slipper valve, the slipper turns in the correct angular range (note position indicator) the manual lever is disengaged 7. Note with underfloor and ceiling heating systems! The limit thermostat must be set to the correct value. During the functional test, the flow temperature may not exceed the maximum permissible level (usually 55 C). If it does, proceed immediately as follows: Either close the valve manually, or Switch off the pump, or Close the pump isolating valve 8. Switch on power. The display must show something (e.g. the time of day). If not, the reason is probably one of the following: No mains voltage Main fuse defective Mains isolator or main switch not ON 9. If one of the operating mode buttons flashes, a room unit or contact H1 overrides the controller. Select operating mode on the room unit. Switch off contact H1. 2522Z13 2462Z06 Siemens Building Technologies / Landis & Staefa Division 74 319 0081 0 a 30.03.2000 1/10

General information about operation Setting elements: Setting knob Display; an operating line is assigned to each setting Buttons for selecting and readjusting values: To select the next operating line below To select the next operating line above To decrease the displayed value To increase the displayed value Adopting a setting value: The setting value is adopted by selecting the next operating line (or by pressing one of the operating mode buttons) Enter --.- / --:-- / --- (deactivating the function): Keep or depressed until the required display appears Block skip function: To select a single operating line quickly, two button combinations can be used: Press and to select the next line block above. Press and to select the next line block below. Setting procedure 1. Make settings on operating lines 1...41 («End-user»), table on pages 3 and 4). 2. Select plant type on operating line 51 (page 4). 3. Enter all adjusted values in the parameter list below. All functions and operating lines required for the selected type of plant are activated and can be adjusted. All operating lines that are not required are locked. 4. Enter the adjusted values in the table provided. 5. Set the service functions (independent of the type of plant). 6. Carry out the final work. Commissioning and functional check Specific operating lines for the functional check: 161 = outside temperature simulation 162 = relay test 163 = sensor test 164 = setpoints or limit values If Er (for ERROR) appears on the display: prompt operating line 50 to pinpoint the error Setting elements 1 2 3 4 BUS 2476Z01 7 8 9 10 1 Operating mode buttons (selected button is lit) 2 Service connector 3 Buttons for operating the display: Prog = select operating line + = readjust the displayed value 4 Operating Instructions 5 Button for manual operation 6 LED for manual operation 7 Buttons for d.h.w.heating ON/OFF 8 Status display (output, temperature levels, holidays) 9 LCD 10 Setting knob for room temperature readjustments 11 Buttons for manual adjustment of valve 5 6 Landis & Staefa RVP320 11 Front of RVP320 Connection diagrams A6 Room unit (QAW50 or QAW70) Outside sensor Heating circuit pump B1 Flow sensor E1 Two-stage burner M3 Charging pump B2 Boiler sensor F1 Limit thermostat Controller RVP3... B31 Storage tank sensor / thermostat F2 Safety limit thermostat S1 Remote control Operating mode Room sensor Data bus Actuator Heating circuit Return sensor M1 Circulating pump 1 ) Multi-functional output Low voltage side RVP300, RVP310, RVP320 B2* B31** 2474A03 D1 D2 B2 B31 M L N * B2 only with RVP320 ** B31 only with RVP310 and RVP320 2/10 30.03.2000 74 319 0081 0 a Siemens Building Technologies / Landis & Staefa Division

Mains voltage side RVP300 RVP310 AC 230 V F1/F2 Y2 F7 Q2 K6 AC 230 V F1/F2 F7 Q3 Y2 Q2 K6 1 ) 1 ) 2474A02 M3 2475A02 RVP320 AC 230 V Q1 F1/F2 F7 Q3 Y2 Q2 K6 1 ) F1 F2 1. 2. M1 M3 2476A02 Settings Legend for the setting tables: Adjustable Display only Line Function, display Default Range Setting Explanations, notes and tips Settings on the «End-user» level Press or to activate the «End-user» level. 1 Setpoint of NORMAL heating 20.0 C 0...35 2 Setpoint of REDUCED heating 14.0 C 0...35 3 Setpoint of holiday mode / frost protection 10.0 C 0...35 4 Weekday (for the heating program) 1-7 1...7 5 First heating period, start of 06:00 00:00...24:00 NORMAL heating 6 First heating period, end of NORMAL 22:00 00:00...24:00 heating 7 Second heating period, start of --:-- 00:00...24:00 NORMAL heating 8 Second heating period, end of --:-- 00:00...24:00 NORMAL heating 9 Third heating period, start of --:-- 00:00...24:00 NORMAL heating 10 Third heating period, end of --:-- 00:00...24:00 NORMAL heating 12 Date of first day of the holiday period --:-- 01.01.... 31.12....... 13 Date of last day of the holiday period --:-- 01.01.... 31.12....... 14 Heating curve, flow temperature setpoint TV1 at 15 C outside temperature 15 Heating curve, flow temperature setpoint TV2 at 5 C outside temperature 30 C 20...70 60 C 20...120 1 = Monday 2 = Tuesday, etc. 1-7 = entire week Day.Month Day.Month Siemens Building Technologies / Landis & Staefa Division 74 319 0081 0 a 30.03.2000 3/10

Line Function, display Default Range Setting Explanations, notes and tips 26 Setpoint of d.h.w. temperature 55 C 20...100 31 Weekday (for the switching program 2) 1-7 1...7 1 = Monday 2 = Tuesday, etc. 1-7 = entire week 32 Start of first «ON period» 05:00 00:00...24:00 33 End of first «ON period» 22:00 00:00...24:00 34 Start of second «ON period» --:-- 00:00...24:00 35 End of second «ON period» --:-- 00:00...24:00 36 Start of third «ON period» --:-- 00:00...24:00 37 End of third «ON period» --:-- 00:00...24:00 38 Time of day 00:00...23:59 Hour:Minute 39 Weekday 1...7 1 = Monday 2 = Tuesday, etc. 40 Date 01.01. Day.Month (e.g. meaning December 2)... 31.12. 41 Year 1995...2094 50 Faults Display function 0 = fault outside sensor Example of display: 20 = fault boiler sensor 30 = fault flow sensor 40 = fault return sensor 50 = fault storage tank sensor / thermostat 60 = fault room sensor 20 = error code 61 = fault room unit 06 = segment number () 62 = wrong room unit connected 02 = device number () 81 = short-circuit on data bus () 82 = same bus address used several times () 100 = two clock time masters on data bus () 140 = inadmissible bus address () Settings on the «Heating engineer s» level Press and simultaneously for 3 seconds, thus activating the «Heating engineer s» level for selecting the type of plant and for setting the plant-related variables. Selecting the plant type: RVP310: Plant type is ready selected (1 1). RVP300 and RVP320: The required plant type must be selected on operating line 51. This activates all functions and shows the operating lines required for the particular type of plant. Example of a selection Line Function, display Default Range Setting Explanations, notes and tips 51 Plant type RVP300 1 0 1 0, 2 0...... For type references, refer to the next RVP310 1 1 1 1 - section RVP320 3 1 3 0, 3 1...... 4/10 30.03.2000 74 319 0081 0 a Siemens Building Technologies / Landis & Staefa Division

Plant types Type of controller Description of plant type Plant diagram RVP300 1 0 Space heating with mixing zone. Three-position control or twoposition control, acting on mixing valve B1 A6 2474S01 E2 2 0 Space heating with district heat. Three-position control or twoposition control, acting on two-port valve E3 B1 A6 2474S02 E2 RVP310 1 1 Space heating with mixing zone. Three-position control or twoposition control, acting on mixing valve. D.h.w. heating through control of the charging pump A6 B1 E2 M3 K6 B31 K6 2475S01 RVP320 3 0 Space heating with mixing zone. Three-position control or twoposition control, acting on mixing valve. Precontrol with boiler E1 B2 M1 B1 A6 2476S01 E2 3 1 Space heating with mixing zone. Three-position control or twoposition control, acting on mixing valve. Precontrol with boiler. D.h.w. heating through control of the charging pump B2 E1 M1 A6 B1 E2 M3 K6 B31 K6 2476S02 A6 Room unit QAW50 or QAW70 E3 Heat exchanger B1 Flow sensor Data bus B2 Boiler sensor K6 Electric immersion heater / circulating pump B31 Storage tank sensor / thermostat M1 Circulating pump Room sensor Heating circuit pump Return sensor M3 Charging pump Outside sensor Controller RVP3... E1 Heat source (boiler) Heating circuit valve E2 Load (room) Siemens Building Technologies / Landis & Staefa Division 74 319 0081 0 a 30.03.2000 5/10

Parameter list Line Function, display Default Range Setting Explanations, notes and tips Block «Space heating» 61 Heating limit for NORMAL heating 17.0 C --.- or Input --.- = function inactive (ECO day) 5...+25 62 Heating limit for REDUCED heating 5.0 C --.- or Input --.- = function inactive (ECO night) 5...+25 63 Building time constant 20 h 0...50 h Light = 10 h, medium = 25 h, heavy = 50 h 64 Quick setback 1 0 / 1 0 = without 1 = with 65 Room temperature source A 0 / 1 / 2 / 3 / A 0 = no room sensor used 1 = room unit connected to terminal A6 2 = room sensor connected to terminal 3 = average of the two devices connected to terminals A6 and A = automatic selection 66 Type of optimisation 0 0 / 1 0 = with room model 1 = with room unit / room sensor Setting 0 only permits optimum start control 67 Max. heating up time 00:00 h 00:00...42:00 Max. forward shift of switching on before h occupancy starts. Setting 00:00 = no optimum start control 68 Max. early shutdown 0:00 h 0:00...6:00 Max. forward shift of switching off before h occupancy ends. Setting 0:00 = no optimum stop control 69 Max. limitation of the room temperature --.- --.- or 0...35 C Input --.- = limitation inactive. Function can only be provided with room unit / room sensor 70 Room temperature influence 4 0...20 Gain factor for influence of the room temperature. Function can only be provided with room unit / room sensor 71 Room temperature setpoint boost 5 C 0...20 with boost heating Block «Actuator heating circuit» 81 Max. limitation of the flow temperature --- --- or Input --- = function inactive 0...140 No safety function! 82 Min. limitation of the flow temperature --- --- or Input --- = function inactive 0...140 C 83 Max. limitation of the flow temperature --- --- or 1...600 Input --- = function inactive /h (function prevents cracking noise) 84 Excess flow temperature mixing valve 10 C 0...50 Excess flow temperature for primary controller / heat exchanger in interconnected plants 85 Actuator running time 120 s 30...873... s 86 P-band of control (Xp) 32.0 C 1...100 Settings required only for three-position actuator 87 Integral action time of control (Tn) 120 s 10...873... s 88 Type of actuator 1 0 / 1 0 = two-position control 1 = three-position control 89 Switching differential 2 C 1...20 Setting required only for two-position actuator Block «Boiler» 91 Boiler operating mode 0 0...2 92 Max. limitation of the boiler temperature 95 C 25...140 93 Min. limitation of the boiler temperature 10 C 5...140 94 Switching differential of boiler 6 C 1...20 95 Min. limitation of burner running time 4 min 0...10... min 96 Release limit burner stage 2 50 0...500 C * min C * min 97 Reset limit burner stage 2 10 0...500 C * min C * min 98 Locking time burner stage 2 20 min 0...40... min 0 = with manual shutdown (button ) 1 = with automatic shutdown (OFF, when there is no demand for heat) 2 = without shutdown No safety function! 6/10 30.03.2000 74 319 0081 0 a Siemens Building Technologies / Landis & Staefa Division

Line Function, display Default Range Setting Explanations, notes and tips 99 Operating mode pump M1 1 0 / 1... 0 = without shutdown in the case of protective boiler startup 1 = with shutdown in the case of protective boiler startup Block «Setpoint of return temperature limitation» 101 Setpoint of return temperature limitation, constant value --- --- or 0...140 Input --- = function deactivated Plant types 1 x, 3 x: min. limitation Plant typ 2 0: max. limitation Block «District heat» 112 Slope of max. return temperature limitation 113 Start of shifting max. return temperature limitation 114 Integral action time of max. return temperature limitation 0.7 0.0... 4.0 10 C 50...+50 30 min 0...60... min Constant value Slope Start of shifting limitation Block «D.h.w.» 121 Assignment of d.h.w. heating 0 0...2 123 Release of d.h.w. heating 2 0...2 124 D.h.w. priority, flow temperature setpoint 0 0...4 126 D.h.w sensor / d.h.w. thermostat 0 0 / 1 127 D.h.w. charging temperature boost 10 C 0...50 128 Switching differential of d.h.w. 8 C 1...20 129 Max. d.h.w. charging time 60 min --- or 5...250... min 130 Setpoint of legionella function --- --- or 20...100 131 Forced charging 0 0 / 1 D.h.w. heating with 0 = own controller 1 = all controllers in the interconnected system with the same segment number 2 = all controllers in the interconnected system 0 = 24 h per day 1 = according to the heating program(s), depending on the setting mode on operating line 121 ; start of release is always shifted forward by one hour 2 = according to switching program 2 D.h.w. priority Flow temperature setpoint acc. to 0 = absolute priority d.h.w. 1 = shifting priority d.h.w. 2 = shifting priority max. selection 3 = none (parallel) d.h.w. 4 = none (parallel) max. selection 0 = sensor 1 = thermostat Input --- = function deactivated Input --- = function deactivated 0 = none 1 = daily with the first release Block «Multi-functional relay» 141 Function «Multi-functional relay» 0 Plant types x 0: 0...2 Plant types x 1: 0...8 0 = no function 1 = relay ENERGIZED in the event of fault 2 = relay ENERGIZED when there is demand for heat 3 = circulating pump ON 24 hours per day 4 = circulating pump ON acc. to heating program(s), depending on the setting made on operating line 121 5 = circulating pump ON acc. to switching program 2 6 = changeover electric immersion heater / heating circuit acc. to own controller 7 = changeover electric immersion heater / heating circuit acc. to all controllers with the same segment number in the interconnected system 8 = changeover electric immersion heater / heating circuit acc. to all controllers in the interconnected system Siemens Building Technologies / Landis & Staefa Division 74 319 0081 0 a 30.03.2000 7/10

Line Function, display Default Range Setting Explanations, notes and tips Block «Service functions and general settings» 161 Outside temperature simulation --.- --.- or 50...+50 Simulation will automatically be terminated after 30 minutes --.- = no simulation 162 Relay test 0 0...9 0 = normal operation 1 = all contacts open 2 = burner stage 1 ON (K4) 3 = burner stages 1 and 2 ON (K4 and K5) 4 = circulating pump ON (M1) 5 = charging pump ON (M3) 6 = heating circuit valve OPEN () 7 = heating circuit valve CLOSED (Y2) 8 = heating circuit pump ON () 9 = multi-functional relay ENERGIZED (K6) To terminate the relay test: select next line, or automatically after 30 min. 163 Sensor test Sensor: = short-circuit = open-circuit Thermostat: = contact closed = contact open 164 Setpoints or limit values = no setpoint or limit value available Display function Display function 0 = outside sensor 1 = flow sensor B1 2 = room sensor 3 = room unit sensor A6 4 = return sensor 5 = storage tank sensor / thermostat B31 6 = boiler sensor B2 0 = no function 1 = flow temperature setpoint 2 = room temperature setpoint 3 = room temperature setpoint 4 = return temperature limit value 5 = d.h.w. temperature setpoint 6 = boiler temperature setpoint (switch-off point) Input --.- = no frost protection for the plant 167 Outside temperature for frost protection 2.0 C --.- or for the plant 0...25 C 168 Flow temperature setpoint for frost 15 C 0...140 protection for the plant C 169 Device number 0 0...16 Data bus address () 0 = device without bus 170 Segment number 0 0...14 Data bus address () 172 Operating mode when connection 0 RVP300: Heating circuit operating terminals H1 M are linked 0...3 mode D.h.w. RVP310 and 0 = Standby OFF RVP320: 1 = AUTO OFF 0...9 2 = REDUCED OFF 3 = NORMAL OFF 4 = Standby ON 5 = AUTO ON 6 = REDUCED ON 7 = NORMAL ON 8 = AUTO ON, 24 h / day 9 = NORMAL ON, 24 h / day 173 Gain of locking signal 100 % 0...200 % Response to locking signals 174 Pump overrun time 6 min 0...40... min 175 Pump kick 0 0 / 1 0 = no periodic pump kick 1 = weekly pump kick active 176 Winter- / summertime changeover 25.03 01.01... 31.12 Setting: earliest possible changeover date 177 Summer- / wintertime changeover 25.10 01.01... 31.12 Setting: earliest possible changeover date 178 Clock mode 0 0...3 0 = autonomous clock in the controller 1 = clock via bus (slave), without remote control 2 = clock via bus (slave), with remote control 3 = controller is the central clock (master) 179 Bus power supply A 0 / A 0 = no power supply via the controller A = power supply via the controller 8/10 30.03.2000 74 319 0081 0 a Siemens Building Technologies / Landis & Staefa Division

Line Function, display Default Range Setting Explanations, notes and tips 180 Outside temperature source A A or 00.01... 14.16 No display means: controller is autonomous (no data bus used) Input when delivered via data bus: segment or device number of source, or A for automatic identification of source 194 Hours run counter Display function Number of controller operating hours 195 Controller s software version Display function Final work 1. Enter the settings in these Installation Instructions. Keep the Installation Instructions in a safe place. 2. Enter the following in the Operating Instructions: Release of d.h.w. heating Function of switching program 2 3. Insert the Operating Instructions in the unit cover. Dimensions 93 19 max. 3 96 26 26 26 26 15 144 106,8 12 14 138 +1 0 60,4 4,5 92 +1 0 56 112 2474M01 Dimensions in mm Siemens Building Technologies / Landis & Staefa Division 74 319 0081 0 a 30.03.2000 9/10

1999 Siemens Building Technologies Ltd. 10/10 30.03.2000 74 319 0081 0 a Siemens Building Technologies / Landis & Staefa Division