MODELS. WATER HEATER VENT PACKAGE For Natural Gas or LP

Discontinued Old-Style Switch

MODEL UC1 INSTALLATION INSTRUCTIONS

MODEL HS115-3, HS115-4 & HS115-5 WIRING DIAGRAM ADDENDUM

CONVERSION TIPS FOR OLD HSUL & HST SERIES POWER VENTERS IMPORTANT!!! UC1 BOARD VERSION X.06 UPDATES

MODELS HSJ HS1 HS2 OWNER INSTRUCTIONS, DO NOT DESTROY. Recognize this symbol as an indication of important Safety Information!

Tjernlund Side Wall Venting Products

TJERNLUND PRODUCTS, INC.

24 VAC SYSTEM CONTROL KIT Model: CK-91F and CK-91FG

24 VAC SYSTEM CONTROL KIT

SYSTEM CONTROL KIT READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

MODEL COP2 (Includes COP2 Control and Transducer) INSTALLATION INSTRUCTIONS

MODEL DCOP1 INSTALLATION INSTRUCTIONS

MODEL CDB8 INSTALLATION INSTRUCTIONS

24 VAC SYSTEM CONTROL KIT

IN-FORCER TM MODELS PAI-1G & PAI-2G PAI-10 & PAI-2O

INSTALLATION INSTRUCTIONS

MODEL UCRT (UC1 with speed control) INSTALLATION INSTRUCTIONS

XCHANGER TM MODEL X2D

MODEL SS1 INSTALLATION INSTRUCTIONS

POWER VENTER SYSTEM MODEL: PVO-300, PVO-600

COMMERCIAL COMBUSTION AIR IN-FORCER TM MODELS PAI-3 PAI-4 PAI-5 PAI-6 PAI-7

INSTALLATION INSTRUCTIONS

POWER VENTER SYSTEM. Model: PVG-100, PVG-300, PVG-600

Mighty Venter Power Vent System

120 VAC SYSTEM CONTROL KIT Model: CK-63

PVE SERIES POWER VENTER SYSTEM MANUAL

120 VAC SYSTEM CONTROL KIT

SIDEWALL POWER VENTER KIT

SYSTEM CONTROL KIT. Model: CK-62. Designed for use on SWG Series Power Vent Hoods for controlling oil fired heating appliances with 120 VAC controls.

POWER VENTER SYSTEM. Model: PVO-300, PVO-600

POWER VENTER. Model: PVE Series

SIDEWALL POWER VENTING KIT

SYSTEM CONTROL KIT Model: CK-41P

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

RS Chimney Fan For Gas & Oil Applications. Installation & Operating Manual USA CAN

MODEL SS1-R INSTALLATION INSTRUCTIONS

LGB Gas fired boiler

COMBUSTION AIR SYSTEM Model: CAS-3

WARNING FLAIR INTERNATIONAL CORPORATION 600 OLD WILLETS PATH HAUPPAUGE, NEW YORK U.S.A. TEL.: (516) FAX: (516) AMERICAN

MODEL SS2 INSTALLATION INSTRUCTIONS

READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

e Bath Fan with Light User s Guide

INSTALLATION AND OPERATION INSTRUCTIONS

24 VAC SYSTEM CONTROL KIT

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

Service Parts, Kits and Accessories

e Bath Fan with Light User s Guide

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

ENERVEX ADC100 DRAFT CONTROL

120 VAC SYSTEM CONTROL KIT

ADC150 Automatic Draft Control

(Information about THERMAL dampers for gas-fired appliances available on request.) WARNING

EBC 10 Fan Control USA CAN. Product Information. ... Chapter 1+2. Mechanical Installation. ... Chapter 3. Electrical Installation. ...

SIDEWALL POWER VENTER KIT

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2

COMBUSTION AIR SYSTEM

INSTALLATION AND OPERATION INSTRUCTIONS

CSD-1 COMMERCIAL BOILER CONTROLS

e Heater/Exhaust Fan/Light User s Guide

e Bath Fan with Light User s Guide

RSIF Power Venter USA CAN. Product Information. ... Chapters Mechanical Installation. ... Chapter 3. Electrical Installation. ...

55-Gallon Dispenser Package

INSTALLING AND OPERATING YOUR MONTIGO GAS-BURNING FIREPLACE

DBF 4XL Dryer Booster Fans

OWNER S GUIDE COMMERCIAL POWER VENTER KITS USED IN CONJUNCTION WITH FLUE DAMPERED COMMERCIAL WATER HEATERS TABLE OF CONTENTS

MODEL SS1-R INSTALLATION INSTRUCTIONS

DR-180 Through the Wall Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE

15Hp/20Hp Deluxe Compressor-Dryer System

Installation Instructions for P/N: Algas-SDI thermostat retrofit kit

INSTALLATION INSTRUCTIONS

USER S INFORMATION MANUAL

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

ELECTRONIC FIREPLACE DAMPER

BIG BOOT COMBUSTION AIR KIT Model: CAS-2BB, CAS-2CB, CAS-2B375

INSTALLATION INSTRUCTIONS

SLANT/FIN AUTOMATIC VENT DAMPER For Galaxy, Sentinel and Sentry Series Boilers INSTALLATION INSTRUCTION MANUAL AND TROUBLESHOOTING GUIDE

CINCINNATI, OH USA

INSTALLATION AND OPERATION INSTRUCTIONS

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

Installation, Operation and Owner s Manual. Power Vent System

ELECTRONIC FIREPLACE DAMPER

INSTALLATION & OPERATION MANUAL

Sound Cover [ , , , ]

USER MANUAL OLM SERIES WARM AIR OIL FIRED FURNACE

External Roof-mounted Power Vent System

Q382A,B Pilot Burners

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

ENERVEX IPVB INLINE POWER VENTER

USER MANUAL SLO / SFLO115 SERIES OIL FIRED WARM AIR FURNACES

OPERATING INSTRUCTIONS SMO112 WARM AIR OIL FIRED FURNACE

UVST (SMOOTH FACE) UVCST (HEAT CIRCULATING) INSTALLATION & OPERATING INSTRUCTIONS

CT500 Electronic Thermostat

Construction Heater GENERAL HAZARD WARNING

breeze easytm model # F100-1W

Bathroom Exhaust Fan/Fluorescent Light Combination

Bathroom Exhaust Fan/Fluorescent Light Combination

RSIF Power Venter. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

CT2700 An Electronic Round Programmable Thermostat

Transcription:

TJERNLUND PRODUCTS, INC. 1601 Ninth Street White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 (651) 426-2993 FAX (651) 426-9547 Visit our web site www.tjernlund.com PRESSURE SWITCH AND INSTALLATION WITH TRADITIONAL The Diagram Below shows how to connect the JA1 Thermocouple Junction Adapter, Linear Limit Spill Switch and Gas Pressure Switch with a traditional gas valve. Typical Tjernlund models this applies to are VP2-F, VP3-F & WHKE. WIRES FROM LINEAR LIMIT ROLLOUT SWITCH TRADITIONAL CONTROL SUPPLY PRESSURE SWITCH THERMOSTAT / CONTROL. WA R HOT M V A C ATI O N PILOT LINE SEE VP-2F, VP-3F OR WHKE MANUAL FOR WIRING OPTIONS JA1 BURNER LINE INSTALL BRASS 1/8-NPT MALE x 1/4" INTO. PRESSURE SWITCH AND INSTALLATION WITH NEW THERMOPILE The Diagram Below shows how to connect the Linear Limit Spill Switch and Gas Pressure Switch with a Thermopile Style Gas Valve. NOTE: The JA1 Thermocouple Junction Adapter is not used with this style of gas valve. The 1/8 - NPT, 2 long male nipple and 1/8 - NPT coupler must be installed into the gas valve pressure tap port as shown below. The Linear Limit Switch must be wired in series with the water heater ECO safety circuit WHITE wire from thermopile gas valve. PRESSURE SWITCH THERMOSTAT / CONTROL. SUPPLY NEW THERMOPILE STYLE CONTROL WIRES FROM LINEAR LIMIT ROLLOUT SWITCH WIRE NUTS BY OTHERS WHITE WHITE SEE VP-2F, VP-3F OR WHKE MANUAL FOR WIRING OPTIONS PILOT LINE BURNER LINE JUNCTION ADAPTER IS NOT USED RED INSTALL 1/8 - NPT, 2" LONG MALE NIPPLE INTO. INSTALL 1/8 - NPT COUPLER INSTALL BRASS 1/8 - NPT MALE x 1/4" COMPRESSION FITTING INTO COUPLER. WATER HEATER FIGURE 8050053 8/13/15 2015 TJERNLUND PRODUCTS, INC. ALL RIGHTS RESERVED. P/N: 8505032

TJERNLUND PRODUCTS, INC. 1601 Ninth Street White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 (651) 426-2993 FAX (651) 426-9547 Visit our web site www.tjernlund.com WHKE MILLIVOLT INTERLOCK KIT FOR USE WITH UC1 UNIVERSAL CONTROL, MAC1E OR MAC4E AUXILIARY CONTROLS DIAGRAM A1 (For interlocking only with UC1 Universal Control, MAC1E or MAC4E auxiliary controls) This Safety Interlock System may only be used on Category 1, millivolt heating appliances equipped with a draft hood or draft diverter. PURPOSE To provide a means for Venter actuation and appliance shut-down in the event of flue blockage, down drafts or Venter failure. OPERATION The Gas Pressure Switch senses gas pressure when the gas valve opens, completing the circuit between A & B of the UC1, MAC1E or MAC4E control which activates the Venter. The Linear Limit Spillage Sensor circuit is normally closed and will not affect normal appliance operation. When concentrated spillage of combustion gases occurs from the draft hood or diverter, the Linear Limit Spillage Sensor circuit will open preventing burner operation by disrupting the heater s millivolt safety circuit. DIAGRAM A2 REPLACEMENT PARTS LIST ITEM DESCRIPTION 950-2064 Linear Limit Spillage Sensor with manual reset, 185 o set point and 6 foot cable 950-2080 Gas Pressure Switch 950-0470 Thermocouple Junction adapter INSTALLATION DO NOT CUT THE COPPER CAPILLARY SENSING TUBE OR LIMIT WILL BE DESTROYED AND APPLIANCE WILL BE DISABLED. SWITCH ROUTING CLIP DRAFT DIVERTER 1. Shut off fuel supply to the appliance. 2. Attach Linear Limit spillage sensor to draft hood (A1) or diverter (A2), see respective diagram. DIAGRAM B Copper capillary sensing tube should not come in direct contact with metal surfaces. Linear Limit spillage sensor should be mounted so that capillary will sample temperature of gases spilling from vent or chimney, not temperature of metal surface. 3. 30 Millivolt water heaters require the 950-0470, Thermocouple Junction Adapter. Unscrew thermocouple from gas valve and screw in Thermocouple Junction Adapter. Screw thermocouple into Thermocouple Junction Adapter. Connect Linear Limit cables to spade connections on Thermocouple Junction Adapter, (see Diagram B). On 750 Millivolt (power pile) heaters, wire Linear Limit spill switch in series with high limit (ECO) of heater. 4. Using cable routing tabs from wire routing packet, attach Linear Limit control cable to appliance maintaining a safe distance from hot surfaces, e.g. appliance vent pipe and hot water pipes. SPILL SWITCH 950-0470 (JA1)

PRESSURE SWITCH INSTALLATION The gas pressure switch is mounted on the casing of the water heater adjacent to the heater's thermostat/gas control valve. It should be mounted close enough so that the supplied 1/4" tubing will reach from the gas pressure switch fitting to the thermostat/gas valve pressure tap port. The two provided screws are self-tapping and drilling. The screws do not require the use of a drill and their 1/2" length assures that the inner tank will not be penetrated. 1. Mount the gas pressure switch by securing it to the heater casing with a screw in each of the two mounting holes. Mount gas pressure switch so that diaphragm is in a VERTICAL position, (See Diagram C). 2. Install the supplied 1/8"-NPT pipe plug to the 90 o port of the supplied 1/8-NPT black pipe tee, (See Diagram C). Use thread sealant, do not over tighten. 3. Install the 1/8-NPT black pipe tee to the gas pressure switch, (See Diagram C). Use thread sealant, do not over tighten. CAUTION: Utilize the hex nut on the gas pressure switch when attaching the black pipe tee. 4. Install the supplied Brass 1/8-NPT male x ¼" compression fitting to the 1/8-NPT black pipe tee, (See Diagram C). Use thread sealant, do not over tighten. 5. Remove the PRESSURE TAP plug from the underside of the thermostat/gas control valve and install the supplied Brass 1/8-NPT male x ¼" compression fitting, (See Diagram C). Use thread sealant, do not over tighten. DO NOT alter the heater's PILOT LINE, (See Diagram C). 6. Using a tube cutter, cut the appropriate length of the supplied 1/4" tubing to reach from the gas pressure switch fitting to the fitting of the thermostat/gas control valve. Make sure each end of the tubing is not pinched closed. 7. Use the 1/4" tubing to connect gas pressure switch fitting to the fitting on the thermostat/gas control valve. 8. Conduct a gas leakage test of all connections as outlined in the latest edition of NFPA 54, ANSI Z223.1, part 4. or local codes. NOTE: A "gauge port" can be accessed by removing the 1/8-NPT pipe plug that is on the 1/8-NPT black pipe tee (attached to the gas pressure switch). DIAGRAM C PRESSURE SWITCH SUPPLY THERMOSTAT/ CONTROL THERMOSTAT / CONTROL. BURNER LINE PILOT LINE INSTALL BRASS 1/8-NPT MALE x 1/4" INTO. FIGURE 700S107 2/13/04

R UC1 UNIVERSAL CONTROL, MAC1E OR MAC4E AND WHKE INTERLOCK KIT CONNECTED WITH A MILLIVOLT APPLIANCE RED JUMPER POSITION MUST BE THE SAME AS APPLIANCE INTERLOCK VOLTAGE. WHKE PRESSURE SWITCH SUPPLY 115 VAC 50/60 Hz GROUND J2 J1 XL XN 115V UNIVERSAL CONTROLLER DRY 24V CALL JUMPER SPILL SWITCH 950-0470 (JA1) LEGEND: 115 VAC 5 VDC BOARD- GENERATED POWER. DO NOT SUPPLY POWER! MILLIVOLT D/N 9183046-9 CRIMP GROUND WIRE TO GROUNDING SPADE TERMINAL IN ELECTRICAL BOX. SAFETY CIRCUIT ACROSS P1 & P2 OF UC1 IS NOT UTILIZED IN THIS APPLICATION. SPILL SWITCH MUST BE INTERLOCKED WITH HEATING EQUIPMENT AS SHOWN. 30 MILLIVOLT WATER HEATERS REQUIRE USE OF THE 950-0470. ON 750 MILLIVOLT (POWER PILE) WATER HEATERS WIRE SPILL SWITCH IN SERIES WITH HIGH LIMIT (ECO) OF WATER HEATER. SPILL SWITCH, 950-0470 AND PRESSURE SWITCH ARE INCLUDED WITH WHKE KIT. CONNECTIONS WITH UC1, MAC1E OR MAC4E Each millivolt appliance interlocked with the UC1, MAC1E or MAC4E must have its own WHKE kit installed. The WHKE Gas Pressure Switch actuates the Venter through the A - B Dry contacts. The Linear Limit switch disables the heater in the event of a venting malfunction. Each millivolt appliance interlocked with the UC1, MAC1E or MAC4E must have its own Linear Limit spill switch. 1. Wire WHKE Gas Pressure Switch across A and B terminals on UC1, MAC1E or MAC4E. Do not supply voltage to A and B terminals. 2. Wire WHKE Linear Limit in series with thermocouple junction adapter or high limit ECO of heater. 3. Make sure RED voltage jumper on UC1, MAC1E or MAC4E is in the DRY position. 4. If not previously completed, connect 115 VAC supply voltage to L & N terminals on UC1. Crimp Ground wire to grounding spade terminal in UC1. Important: Installer must supply overload and disconnect protection. 5. If not previously completed, connect ground from UC1 whip to Venter ground. Connect Black and White leads from UC1 whip to Venter motor leads. Connect Blue and Yellow leads from UC1 whip to Venter Fan Prover switch. Prover Leads are not polarity sensitive. If using a Draft Inducer and only venting millivolt appliances the PS1505 Fan Proving Switch is not necessary, see below for further information. DRAFT INDUCERS WITH ONLY MILLIVOLT APPLIANCES (PS1505 FAN PROVER NOT REQUIRED) When venting only millivolt gas control(s) with a draft inducer, the PS1505 fan prover is not necessary. It will, however, be necessary to "jumper" the P1 and P2 terminals on the UC1 Universal Control. Remove the call jumper across J1 and J2 and place it across P1 and P2 on the UC1. Deactivate the Prover Status Check circuit by pushing the #9 dip switch up, or to the "deactivated" position in the UC1 Universal Control. See Prover Status Check Dip Switch Settings in the Venter or UC1 instruction manual. The P1 & P2 proving switch circuit of the UC1 cannot control the burner operation of a millivolt gas control. When using a WHKE millivolt interlock kit, the appliance safety shutdown is accomplished by the Linear Limit spill switch which detects flue gas spillage. WARNING: The P1 & P2 proving switch circuit must only be jumpered when venting strictly millivolt appliances where the safety is provided by the Linear Limit. HS-SERIES POWER VENTERS WITH ONLY MILLIVOLT APPLIANCES (FAN PROVING SWITCH PROVIDED) When venting only millivolt gas control(s) with an HS-Series power venter connect Fan Prover leads as outlined above in step 5. The fan prover will not control the millivolt gas valve, but its inclusion is beneficial to proper sequencing of the UC1 control. MULTIPLE APPLIANCE INTERLOCKS WITH A MILLIVOLT AND A 24-115 VAC CONTROLLED APPLIANCE When using a WHKE millivolt interlock kit the millivolt appliance safety shutdown is accomplished by the Linear Limit spill switch which detects flue gas spillage. The P1 & P2 proving switch circuit of the UC1 Universal Control cannot control the burner operation of a millivolt gas control. When co-venting a 24-115 VAC gas control with a millivolt gas valve (i.e. furnace and water heater combo) the P1 & P2 proving switch circuit only interlocks the 24-115 VAC gas control. The millivolt appliance safety shutdown is accomplished by the Linear Limit spill switch which detects flue gas spillage. WARNING: Do not jumper the P1 & P2 proving switch circuit when co-venting millivolt and 24-115 VAC gas valves.

WHKE OPERATION CHECK 1. Confirm power is supplied to the UC1 Control. (LED #6 RED Version 4.06 or later) or (LED #5 RED Versions prior to 4.06 ) on UC1 should be on. 2. Initiate a call for heat on appliance WHKE is installed on. LED #1 (AMBER) on UC1, MAC1E or MAC4E should be on. 3. The UC1 motor relay will close and activate the Venter motor. LED #3 (GREEN) on UC1 should be on. 4. Burner should fire and (LED #2 BLUE Version 4.06 or later on UC1, Version F of MAC1E / MAC4E) or (LED #2 GREEN Versions prior to 4.06 on UC1, or prior to Version F on MAC1E / MAC4E) should also be on. Venter should operate simultaneously with burner ignition. Verify burner lights off properly. WHKE SAFETY INTERLOCK TEST The Linear Limit switch must disable the heater in the event of a venting malfunction. The following procedure is necessary to confirm that the appliance is disabled in the event of a venting malfunction. 1. Remove power to the UC1 Universal Control. 2. Adjust thermostat to call for heat. 3. Venter should not run with UC1 power removed, but the appliance should fire. 4. Flue gas spillage will emit from the draft hood or diverter. Linear Limit spillage sensor should open in less than two minutes, preventing thermostat signal from reaching burner. If Linear Limit does not open, remove call for heat, reposition Limit and repeat steps 1-4. 5. Wait 2-3 minutes and push reset button on Linear Limit spill spill switch. COMBUSTION AIR TEST The Linear Limit spill switch is designed to alert the user to a potentially hazardous condition. It is not designed to, and cannot replace regular chimney inspection, appliance servicing and combustion testing. DO NOT USE THE LINEAR LIMIT AS A SUBSTITUTE FOR PROFESSIONAL APPLIANCE MAINTENANCE. 1. Close all doors and windows of the building. If appliance is installed in utility room or closet, close the entrance door to this room. Close fireplace dampers. Turn on clothes dryer and all exhaust fans such as range hoods, bathroom exhausts and whole house fans to maximum speeds. 2. Place in operation the appliance that the WHKE has been installed on. Set thermostat for continuous operation. 3. Allow fans and appliance to operate for 15 minutes. 4. Tripping of the Linear Limit Spillage Sensor circuit during the 15 minute appliance operation indicates an unsafe operating condition. Check appliances for venting malfunction and check for adequate combustion air. Turn off fuel supply to appliance and DO NOT OPERATE UNTIL UNSAFE VENTING CONDITION IS INVESTIGATED BY PROFESSIONAL CONTRACTOR OR UTILITY SERVICE PERSONNEL. 5. Return all windows, doors and fans to their previous conditions of use. NOTE: For further assistance contact Tjernlund Products, Inc. Customer Service Department at 1-800-255-4208. 7:30 AM-4:30 PM CST. TJERNLUND LIMITED ONE YEAR WARRANTY Tjernlund Products, Inc. warrants to the original purchaser of this product that the product will be free from defects due to faulty material or workmanship for a period of (1) year from the date of original purchase or delivery to the original purchaser, whichever is earlier. Remedies under this warranty are limited to repairing or replacing, at our option, any product which shall, within the above stated warranty period, be returned to Tjernlund Products, Inc. at the address listed below, postage prepaid. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF, AND TJERNLUND PRODUCTS, INC. EXPRESSLY DIS- CLAIMS LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OF THIS PRODUCT. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES AND NO AGENT IS AUTHORIZED TO ASSUME FOR US ANY LIABILITY ADDITIONAL TO THOSE SET FORTH IN THIS LIMIT- ED WARRANTY. IMPLIED WARRANTIES ARE LIMITED TO THE STATED DURATION OF THIS LIMITED WARRANTY. Some states do not allow limitation on how long an implied warranty lasts, so that limitation may not apply to you. In addition, some states do not allow the exclusion or limitation of incidental or consequential damages, so that above limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which may vary from State to State. Send all inquiries regarding warranty work to Tjernlund Products, Inc. 1601 9th Street, White Bear Lake, MN 55110-6794. Phone (651) 426-2993 (800) 255-4208 Fax (651) 426-9547 Email fanmail@tjfans.com. REV. A 04/06 2006 TJERNLUND PRODUCTS, INC. P/N 8504108