Operating manual GTL 369 GTL 369M GTL 389 GTL 389M. Temperature probe. Please keep the manual for future use.

Similar documents
Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

GMH 285 / GMH 285-BNC

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

Flameproof Manual Call Points

Original instructions Sense7-series Non-contact coded safety switch

SITRANS. Temperature transmitter Functional safety for SITRANS TW. Introduction. General safety instructions 2. Device-specific safety instructions

FSW300 Series Flow Switch

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

English. Operating manual. Safety temperature limiter STL50 Approved in accordance with: DIN EN (replacing DIN 3440) SIL 2

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

COMPACT FLAME CONTROLLER CFC 1000

Temperature Sensor TRG Original Installation Instructions English

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

COMPACT FLAME CONTROLLER CFC 2000

2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

M-Sens 2. Online-Moisture Meter for Solids. Operating Instructions. SWR engineering Messtechnik GmbH

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

Operating Manual MS220KA and MSR220KA

Magnetic-Inductive Flow Velocity Sensor PIT. Device Description

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

Electronic Temperature Controller 70304,

MANUAL Oil Level Sensor

itemp RTD TMT 187 itemp TC TMT 188 Temperature head transmitter

OPTISENS TUR 2000 Technical Datasheet

Radar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets with screw connection (16/32 A)

Instruction Manual. Electronic gas and smoke detector GRM

Magnetic-Inductive Flow Velocity Sensor PIT. Installation and Operating Instructions

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Installation manual extra-low-voltage socket outlets for panel- and surface-mounting

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

for relative humidity and temperature

3-way switching valve

BN30 OPERATING MANUAL SOCKET THERMOSTAT TRT-BA-BN30-TC-001-EN

FlowJam S Ex. Bulk Flow Detection. Operating Instructions. SWR engineering Messtechnik GmbH

M-Sens 2. Online moisture measurement for solids. Operating Instructions. SWR engineering Messtechnik GmbH PART OF THE ENVEA GROUP

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

FACTORY AUTOMATION. Instruction Manual NBB20-L2-E2B-C-V1 NBN40-L2-E2B-C-V1 Inductive Sensor

Thermocouples and Resistance Thermometers

SCHMIDT LED Measured Value Display MD Instructions for Use

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

VERSAFLOW VORTEX Supplementary instructions

Functional Safety Manual June pointek CLS500/LC500

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Installation instructions and operating manual. Sauna control system FCU1000 / FCU1200

GMA Panels with double busbar

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

Operating Instructions. Electromagnetic Flowmeter Flowcont FN Hygienic version Flowcont LN

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

Operating Manual MS220DA

Operating Guide Safe Torque Off

E21.X.01.6C-05 Operating Manual EB2000 MC page 1. Operating manual EB2000 MC. for up to 9 sensor modules. Version 3.0

Original operating instructions Safety switch with guard locking AC901S AC902S

MANUAL Overflow sensor NVF-104/34-PF

Installation instructions

EtherCAT Box Modules (EPxxxx-xxxx)

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets QUICK-CONNECT (63 A)

SITRANS T temperature transmitters A broad product family for every application. sitrans

PROCESS AUTOMATION. Instruction manual. Fieldbus Terminators F*-FT-EX1.I.IEC F*-FT-EX1.D.IEC

VC-1, VC-1-SL, VC-2-L, VC-2-SL

Warning Caution. Safety Precautions (Be sure to read these precautions before using our products.)

UFM-T100H US ES CA Power Alarm Test TM

1592P01. for liquids in piping DN

FlowJam Bulk Flow Detection

OPTIBAR DP 7060 Supplementary Instructions

Original instructions JSNY7 Magnetic switch

1 Safety instructions. 2 Device components. Presence detector. Operating instructions

Temperature measurement with current output and PNP/NPN transistor switching output output 2 reprogrammable as switching output TS-400-LI2UPN8X-H1141

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Operating instructions

7NG , 7NG

Operating Guide Safe Torque Off

Temperature sensors SensyTemp TSP Measuring insets TSA

Alarm System SECURE AS 302

Installation manual plugs and connectors QUICK-CONNECT (63 A)

WDB2 Series Bearing Temperature Sensor

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

Energy management function at adsorption dryer PDAD

Instruction Manual September 2010 SITRANS LVL200S

Installation and Operating instructions for. C9900-U battery pack. Version: 2.0 Date:

Duct and Rough Service Carbon Monoxide Sensor

OPTIBAR P 1010/2010 C Supplementary instructions

Installation, Operating and Servicing Instructions

Series: MBC1-TC Mini Benchtop Temperature Controller

BES M30EP-PFC12F-S04G-D12 BES Q40ZU-PFC15B-S04G-D12 BES Q40ZU-PFC20F-S04G-D12 Inductive Safety Sensors User's Manual

Installation and assembly instructions. for standard configuration radial blowers

FDBZ290 Air sampling smoke detection kit Technical Manual

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Service package PDAD- -SP (en) Assembly instructions d [ ]

AIRGOCLEAN 10 E OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN

Transcription:

Operating manual Temperature probe GTL 369 GTL 369M GTL 389 GTL 389M Please keep the manual for future use. L02.0.3X.6C-01

GREISINGER electronic GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49(0)9402-9383-0 Fax -33 www.greisinger.de info@greisinger.de Table of contents Page 1 Intended use (application area)... 3 1.1 Safety signs and symbols... 3 1.2 Safety instructions... 4 1.3 Product liability and warranty... 4 1.4 Standards and directives... 4 1.5 Approval... 4 2 Product description... 5 2.1 Scope of supply... 5 2.2 Ambient temperature... 5 2.3 Design of temperature probe... 5 2.4 Type label... 6 3 Mounting and electrical installation... 6 3.1 Mechanical mounting... 6 3.2 Welding instructions... 7 3.3 Electric installation... 8 3.4 Connection... 8 4 Operating elements and functions (GTL 369M / GTL 389M)... 9 5 Commissioning, maintenance and servicing... 10 5.1 Commissioning... 10 5.2 Maintenance... 10 5.3 Servicing... 10 6 Technical data... 11 6.1 Mechanical design / dimensions... 12 6.2 Ordering code... 13 6.3 Accessories... 14 7 Device transport and storage... 14 8 Returns... 14 9 Disposal... 15 10 Imprint... 15 11 EC conformity certificate... 16 2 /16

1 Intended use (application area) The chapter Product description provides details on the application area. The operational safety of the device is only ensured for the intended use according to this manual. Any changes not described in this manual must only be done by personnel authorized by the manufacturer due to security and warranty aspects. Unauthorized reconstructions or changes are expressly prohibited. Application-specific hazards may be provoked by improper or not intended use of this device. The device must not be used in potentially explosive areas or for security-related components according to SIL. General safety notices, application This manual must be kept at a place at which it can be looked at any time by the qualified personnel. All procedures described in this manual must be done only by skilled and authorized personnel with adequate protective clothing. All rights reserved. 1.1 Safety signs and symbols Warnings are labeled in this document with the followings signs: GEFAHR Caution! This symbol warns of imminent danger, death, serious injuries and significant damage to property at non-observance. Attention! This symbol warns of possible dangers or dangerous situations which can provoke damage to the device or environment at non-observance. Note! This symbol point out processes which can indirectly influence operation or provoke unforeseen reactions at non-observance. Table 1 3 / 16

GREISINGER electronic GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49(0)9402-9383-0 Fax -33 www.greisinger.de info@greisinger.de 1.2 Safety instructions Read this document carefully before you use the device. Assure that the device is suitable for the desired application The operator is responsible for interference-free operation. He must assure the accordance to required job safety measures of the current applicable regulations during the whole period of application. GEFAHR 1.3 Product liability and warranty Disclaimer: The content of the manual is checked for conformity to the described device. However, differences cannot be excluded completely. Therefore we cannot guarantee full conformity. All information of this manual are continuously checked and necessary corrections are included to the following editions. Technical modifications are reserved. Additionally all claims are subject to the latest General Terms of Delivery for Products and Services of the Electrical Industry (ZVEI). Please note that Greisinger electronic cannot check or repair devices without the specified, fully completed form (see chapter 8, Returns ). 1.4 Standards and directives Conform to EMVG 2004/108/EG CE-conformity EN 61326-2-3:2007-05 Vibration test EN60068-2-6 1.5 Approval EHEDG Conform to FDA and 3A 4 /16

2 Product description The GTL 369 and GTL 389 are compact temperature probes. The GTL 369M and GTL 389M are compact temperature probes with for collecting and converting temperature input signals. 2.1 Scope of supply Temperature probe This operating manual Possibly further documents 2.2 Ambient temperature Restrictions dependent on ambient temperature (recommended values) Max. ambient temperature Max. process temperature Note up to 20 C 150 C up to 40 C 130 C 140 C if t 30min up to 60 C 110 C 120 C if t 30min Note: The max. permitted process temperature depends on the ambient temperature and must not be exceeded to ensure faultless functioning. 2.3 Design of temperature probe housing type label no thread sensor tip Figure 1 5 / 16

GREISINGER electronic GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49(0)9402-9383-0 Fax -33 www.greisinger.de info@greisinger.de 2.4 Type label The type label provides important identification data: Type and article name Technical data Serial number Figure 2 GTL 369 / 389 Figure 3 GTL 369M / 389M 3 Mounting and electrical installation 3.1 Mechanical mounting The correct seating of the device, correct function and sealing of the connection can only be ensured by suitable welded sleeves e.g.: GKEV-25/76, GEMK-25/76. The device is not suitable for use in abrasive materials. No additional sealing material (e.g. Teflon tape) must be used on the sealing cone or on the thread. Use a suitable welding mandrel for the correct installation of GHMadapt welded sleeves. The switch must not be sued as a welding aid. Figure 4 Compression fitting 6 /16

3.2 Welding instructions Welding in tanks: Figure 5 1. Drill a hole with the outer diameter of the sleeve, max. tolerance +0.2 mm 2. Tack the sleeve in place at 4 points (Fig. 5) Note the correct sequence of the tacking 3. Screw in the welding aid (see Product information GHMadapt AMH121, -122, -123) 4. Weld the sections between the tacks 4 sections for thread M12 Welding in pipes: In addition to the APH pipe system, ball sleeves or sleeves with a welding shoulder for pipes with collars are also available. Note the maximum permissible tightening torque when mounting! Remove the switch before carrying out any welding work on the tank. This will avoid damage to the electronics due to inductive coupling. The case must not be used for screwing in! Tightening will result in damage to the electronics. Use the hexagonal provided for screwing in the switch. In order to avoid excess heating or warping of the sleeve during the welding process, allow a pause between the individual sections so that the sleeve can cool down. 3.2.1 Instructions for installation to EHEDG The installation without gap and dead space is based on the hygienic elastomer-free sealing principle. For this purpose, we offer corresponding fitting accessories such as sleeves and adapters with the GHMadapt sealing principle. 7 / 16

GREISINGER electronic GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49(0)9402-9383-0 Fax -33 www.greisinger.de info@greisinger.de 3.3 Electric installation GEFAHR The device must be installed only by a qualified electrician. The national and international regulations for the installation of electrical systems of the relevant operator country apply. Power supply according to DIN EN66664-1, SELV, PELV. 3.4 Connection GTL 369M GTL 369 Figure 6 Figure 7 GTL 389M GTL 389 Figure 8 Figure 9 8 /16

4 Operating elements and functions (GTL 369M / GTL 389M) The transmitter integrated in GTL 369M / GTL 389M provides several configuration possibilities. For parameterization the GTL - Configuration tool is needed. The operating manual of the GTL - Configuration tool provides detailed information. The following parameters are supported: Measuring range Filter Default state Parameter measuring range: 5 predefined and a freely selectable measuring range can be chosen. M1: -10..+40 C M2: 0..50 C M3: 0..100 C M4: 0..150 C M5: 0..200 C MB: measuring range freely selectable, span 50 K Parameter filter Integrated software filter (low-pass filter) to smooth the output signal. 4 filter steps are available: 0: Filter off, maximal reaction time 1: T 90 approx. 250 ms 2: T 90 approx. 800 ms 3: T 90 approx. 3000 ms Parameter default state This parameter allows selecting whether < 3.75 ma or > 20.5 ma is outputted in case of a detected error. 9 / 16

GREISINGER electronic GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49(0)9402-9383-0 Fax -33 www.greisinger.de info@greisinger.de 5 Commissioning, maintenance and servicing 5.1 Commissioning 1. Check the integrity at the sleeve. 2. Ensure that the M12-plug is correctly fitted. 5.2 Maintenance When cleaning take care that case surface and seals are not attacked by the cleaning agent. If the case is cleaned using a high-pressure cleaning appliance, ensure not to direct the spray jet at the electrical connection. Deposits of cleaning agents on the thread must be avoided. 5.3 Servicing Clean the switch (and especially the sealing cone) and the auxiliary tool after dismantling and before refitting the device carefully with suitable tools and agents, in order to maintain the integrity and hygiene requirements. The device itself cannot be repaired. 10 /16

6 Technical data Housing Probe head Protection tube and tip Protection class : 1.4305 (V2A) : 1.4404 (V4A) : IP67 / IP69K Ambient conditions Working temperature : -20..+70 C Storage temperature : -20..+85 C Climate class : EN 60068-2-38:06/2010 Vibrations : EN 60068-2-6 Sensor Sensor type : Pt100 to IEC 60751 Temperature range : -40..200 C (probe tip) Accuracy : class A, class AA Response time : FS Ø 3 mm: T 90 1.5 s : FS Ø 6 mm: T 90 7.4 s Process temperature : -20..+200 C (see chapter 2.2) : CIP-/SIP-capable Process pressure : max.10 bar Process material : 1.4404 (V4A) Process connection : no thread : suitable welded sleeves e.g. : GKEV-25/76, GEMK-25/76 Electric connection : M12-plug or cable gland Transmitter (GTL 369M / GTL 389M) Supply voltage : 10..28 V DC Measuring ranges : -10 C..+40 C, 0 C..+50 C, 0 C..+100 C : 0 C..+150 C, 0 C..+200 C : or freely selectable within range -20..200 C Measuring span : 50K Accuracy : 0.2% FS Temperature drift : 0.01 % FS/K Reaction time* : 200 ms (filter off) : filter selectable in 4 steps Initialization time : 1.5 s Output : 4..20 ma, 2-wire Sensor break / short circuit: 3.75 ma or 20.5 ma 11 / 16

GREISINGER electronic GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49(0)9402-9383-0 Fax -33 www.greisinger.de info@greisinger.de 6.1 Mechanical design / dimensions GTL 369 GTL 369M GTL 389 GTL 389M Figure 10 12 /16

6.2 Ordering code 1. 2. 3. 4. 5. 6. GTL - - - - - 1. Design type 369 cable connection M12-plug 369M cable connection M12-plug with integrated transmitter 389 fixed cable 2.5 m 389M fixed cable 2.5 m with integrated transmitter 2. Fitting length EL 0050 50 mm 0100 100 mm 0150 150 mm 0250 250 mm xxxx any EL in mm (e.g. 320 = 320 mm) Ø 6: max. 1000 mm 3. Diameter protection tube and probe tip 6 Ø 6 mm, without taper 3 Ø 6 mm, with tapered probe tip Ø 3 mm 4. Accuracy class A class A D class AA (1/3 class B) 5. Transmitter GTML2 (programmable) only for design types 369M and 389M 00 without transmitter (design types 369 / 389) M1 measuring range -10..+40 C M2 measuring range 0..50 C M3 measuring range 0..100 C M4 measuring range 0..150 C M5 measuring range 0..200 C MB transmitter with special measuring range in C (state special measuring range separately e.g.: 0..75 C or -20..+30 C) keep a minimum range of 50 C 6. Option 00 without option TK Teflon cable for connection via fixed cable (only available for 182 and 182M) 13 / 16

GREISINGER electronic GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49(0)9402-9383-0 Fax -33 www.greisinger.de info@greisinger.de 6.3 Accessories For sleeves, adapters and connection cables, see separate product information Accessories Hygienic Design. 7 Device transport and storage The case must be packed carefully and stress-free for transport (no automatic binding of the packaging). The device must be stored under the ambient conditions specified in the technical data. 8 Returns GEFAHR Legal regulations for the protection of the environment and our personnel require that returned devices which have come into contact with media can be handled without risk to personnel and the environment. If you send a device back to us for checking or repair, we must request that you pay strict attention to the following requirements: A returns form can be downloaded from our homepage under: Download / Repair/Service. The repair can be carried out quickly and without further questions if: 1. A completed form is available for every device. 2. The device has been cleaned and returned in packaging which prevents any damage to the device. 3. The completed form and any possible safety data sheet on the measurement medium are attached to the outside of the packaging. 14 /16

9 Disposal The device components and packaging must be separated by materials for disposal. The legal regulations and guidelines applicable at the relevant time must be observed. The device must not be disposed of as general waste. If a device is to be disposed of, send it back to us direct with the completed Returns form specified under Point 8 and we will then take care of proper disposal. 10 Imprint Managing Director: Günther Oehler Place of fulfillment and jurisdiction: Regenstauf Copyright: GREISINGER electronic GmbH. All rights reserved. Reprinting, digital use of any type and duplication is allowed only with the written permission of GREISINGER electronic GmbH. 15 / 16

11 EC conformity certificate