Installation and Operation Manual

Similar documents
MODEL SST 2 40 FREEZE PROTECTION THERMOSTAT MODEL SST FIXED SET POINT THERMOSTAT. Installation and Operation Manual

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Freeze Protection Thermostat TRACON MODEL GPT 3 Installation and Operation Manual

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

ADDITIONAL INFORMATION

Model GPT 3 Freeze Protection Thermostat

SAFETY INFORMATION AND WARNINGS

Model GIT 4 Gutter Snow and Ice Melting Control

MANUAL Rev. C 02/15 (800) Environmental Technology, Inc.

MODEL GF PRO AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

SC-40 Satellite Contactor

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

SAFETY INFORMATION AND WARNINGS

PROJECT MANAGEMENT Transmittal No 17D

Warranty Info: ETI s warranty policy can be viewed at:

Installation, Operation & Service Manual

SMPG1 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL FOR SINGLE-PHASE HEATING CABLES PRODUCT OVERVIEW

SMPG3 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL. For three-phase heating cables PRODUCT OVERVIEW

CHAPTER 20 SERVICE EQUIPMENT

100A / 200A. Maximum Heating Load: Enclosure Type: NEMA 4

INSTALLATION, OPERATION AND MAINTENANCE

tcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

NXM2G Installation and Operating Manual

Liebert Fin/Tube Condenser Warranty Inspection Check Sheet

ECW-GF, ECW-GF-DP DIGITAL ELECTRONIC CONTROLLERS AND REMOTE DISPLAY PANEL PRODUCT OVERVIEW

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

THERMAL MANAGEMENT SOLUTIONS

DTA. Motor thermistor relay. Benefits. Description

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

CSI Master Format 2004 Guide Specification for: Snow Melting (Mineral Insulated)

FPC-02 Series. Installation and Operating manual

SPA HEATER INSTALLATION, OPERATION AND MAINTENANCE

THERMAL MANAGEMENT SOLUTIONS

WATLOW IND. FIREBAR Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

SECTION LOW VOLTAGE LIGHTING CONTROLS

M Series Fan Filter Units

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

SECTION RADIANT-HEATING ELECTRIC CABLES / MATS

Public Safety DAS Annunciator Panel

PART GENERAL 1.01 SECTION INCLUDES

SECTION RADIANT-HEATING ELECTRIC CABLES PART 1 - GENERAL 1.1 SECTIONS INCLUDES

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated)

TC-5231 Series, TC-5232, & TC-5241 Series

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

SECTION AUTOMATIC TRANSFER SWITCHES

INSTALLATION / OPERATING INSTRUCTIONS

Remote Relay Module (RRM)

TMC Temperature Monitoring Control Temperature Range -30 to 250 F (-35 to 120 C)

INSTALLATION & OPERATION MANUAL

Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual

Dual Input ph/orp Analyzer

PURGE/PRESSURIZATION SYSTEM

AGF Manufacturing Inc. Model Owner s Manual INST-5400A_V /15

CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

Installation Instruction Manual ILS-S

Dual Input Toroidal Analyzer

Greentrol Automation, Inc.

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

Scully ST-15 WX. Technical Manual. Multi-Point Liquid-Level Detection System

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

- Data Brochure. This brochure is for Thermostats 510 and 511 (with sensor). The section on the 079 slab sensor installation is for the 511 only!

Figure 1. Figure 2. See notes 1 and 2 below.

BACKUP BATTERY INSTALLATION INSTRUCTIONS

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

GRUNDFOS INSTRUCTIONS CMBE. Installation and operating instructions. Drinking Water System Component NSF / ANSI 61 NSF / ANSI 372

ROOF AND GUTTER DE-ICING ICESTOP SYSTEM

Installation Instructions

OPERATION MANUAL. CLASSIC 10 and CLASSIC 18 SERIAL NUMBER FROM JANUARY 2009 (0109) TO PRESENT

INSTALLER S & OWNER S MANUAL

59T, 66T Series Electric Water Heater Controls

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

Powers Controls ET 134 Low Temperature Detection Thermostat

IceStop System INSTALLATION AND OPERATION MANUAL FOR ROOF AND GUTTER DE-ICING SYSTEMS

Oxygen (O2) Single-Point Gas Detection System

Quest Power Electric Heat EHS 31 Pro

INSTALLER S & OWNER S MANUAL

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

Radiant Thermostat 519

FLCH4R Garage and Utility Electric Heater

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

Powers Controls Low Temperature Detection Thermostat

Instruction Manual WARNING

Drexan Energy Systems Inc.

Owner s Manual Phoenix FireBird

PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Rev D.01

Transcription:

Electronic Thermostats with Ground Fault Equipment Protection Model SST 2 40 Freeze Protection Thermostat P/N 22744 MANUAL We Manage Heat Model SST 2 175 Fixed Set Point Thermostat P/N 23708 Installation and Operation Manual Environmental Technology, Inc. 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239 FAX (574) 233-2152 or (888) 234-4238 http://www.networketi.com/ 22804C 12/14 (800) 234-4239 http://www.networketi.com Environmental Technology, Inc.

Model SST 2 Safety Make all electrical connections in compliance with the National Electric Code (NFPA 70) and local electrical code. If you have questions concerning the installation or application, contact Customer Service. Additional Information More information is regularly made available through our website, www.networketi.com. Please visit us online for datasheets, manuals, white papers, technical articles and more. The most current and up to date version of this and every other manual for our products can be found in Acrobat (pdf) format to view online or to print. This is to assist you in installing and using our products to the best effect possible. If you have any comments about this or any other material from Environmental Technology please contact us. Contacting Environmental Technology For assistance, contact Customer Service. Office hours are 8:00 AM until 5:00 PM ET. Voice: Fax: E-mail: Mail: (800) 234.4239 (USA and Canada) or (574) 233.1202 (elsewhere) (888) 234.4238 (USA and Canada) or (574) 233.2152 (elsewhere) helpdesk@networketi.com Environmental Technology, Inc. 1850 North Sheridan Street South Bend, IN 46628 2 of 8 Environmental Technology, Inc. http://www.networketi.com (800) 234-4239 12/14 22804C

General Model SST 2 Description The C-UL-US listed SST 2 Fixed Set Point Thermostats replace electromechanical thermostats in cost-sensitive applications requiring ground fault equipment protection (GFEP). The SST is classified to UL and CSA safety standards by UL for use in temperature-regulation applications. It is the ideal low-cost thermostat for areas not subject to mechanical abuse. Installation Unpacking Immediately inspect the packing material for damage. Unpack the SST 2, taking care not to damage the packaging material. Save the packaging material until normal operation has been established. If the unit must be returned, take care to ensure that it is repackaged as it was received. Packing List SST 2 40 22744 SST 2 40 Freeze Protection Thermostat 19272 Temperature Sensor 22804 SST 2 Installation and Operation Manual SST 2 175 23708 SST 2 175 Fixed Set Point Thermostat 23846 Temperature Sensor, High Temp 22804 SST 2 Installation and Operation Manual Initial Inspection Inspect the SST for shipping damage. If any of the following problems are found contact the Customer Service Department. Contents incomplete or incorrect Internal or external mechanical damage Customer service is available between 8:00 a.m. and 5:00 p.m. ET at (574) 233 1202 or (800) 234 4239. In the event of shipping damage, keep the packing materials for inspection by the carrier. Normally, Environmental Technology, Inc. will repair or replace the SST without waiting for the claims settlement. 22804C 12/14 (800) 234-4239 http://www.networketi.com Environmental Technology, Inc. 3 of 8

Model SST 2 Location Housed in a NEMA 4X rated enclosure, the SST fixed set point thermostat can be mounted in either indoor or outdoor environments. The SST controller was designed to operate in an ambient temperature range of 40 to 130 F ( 40 to 55 C). Using the integral mounting flanges, the SST is intended to be installed on a fixed, flat, vertical surface. The mounting flanges accommodate 1 /4" (6mm) fasteners. The SST fixed set point thermostat nonmetallic enclosure is furnished with two 3 /4" (21mm) conduit entries. The conduit entry at the top left side of the enclosure is for line voltage supply branch circuit conductors. The lower conduit entry provides for heater load branch circuit conductors. The installed weather-tight fitting is for the low voltage, NEC Class 2, temperature sensor. The temperature sensor may be located up to 2,000' (610m) from the SST-2. Supply Voltage The SST fixed set point thermostat operates from 120, 208, 240 or 277 VAC at 50/60 Hz. For line supply and load connections, use 10 AWG or larger wires rated for at least 75 C (167 F) at 300 VAC. Contactor Rating The heater contactor provides two (2) Form A (DPST) definite purpose contacts rated for up to 30 amp AC heater loads at voltages at or below 277 VAC. NEC Class 2 Low Voltage Connections All low voltage wiring shall use 18 AWG or greater stranded conductors with thermoplastic insulation rated for at least 75 C (194 F) at 300 VAC. The temperature sensor is supplied with a 20' (6m) 2-wire jacketed cable lead. The temperature sensor lead may be up to 500' (152.4m) using 18 AWG 2-wire jacketed cable, or up to 2,000' (609.6m) using 12 AWG 2-wire jacketed cable. Temperature Sensor The temperature sensor is required for the operation of the SST. The temperature sensor connects via wire nuts to the two blue wires in the SST enclosure. Connect the sensor s RED wire to either SST-2 BLUE wire and connect the sensor s BLACK wire to the remaining blue wire. (NOTE: It does not matter which sensor wire is connected to which BLUE wire in the enclosure.) The sensor should be located near the heater being controlled and is used to monitor its temperature. Its placement is dependent upon application: Consider/confirm ambient air temperatures for chiller lines, etc. Water supply lines (in-line heating) on pipe under insulation Sprinkler system freeze protection on pipe under insulation (consider pipe temperatures in unheated facilities) 4 of 8 Environmental Technology, Inc. http://www.networketi.com (800) 234-4239 12/14 22804C

Operating Instructions Model SST 2 Power On Startup Test When power is applied to the SST 2 fixed set point thermostat, the LED indicator lights in the SST enclosure will cycle for two seconds and then turn off, except for the green SUPPLY indicator, which will remain lit whenever the SST senses supply power. Next, the SST 2 fixed set point thermostat performs a self-test of the ground fault circuitry. This is the same test automatically performed approximately every 24 hours. Failure of the ground fault circuitry self-test will disable the SST; call Customer Service. Operation The SST 2 fixed set point thermostat does not require user attention during normal operation. Status indicator SUPPLY (green) power applied SUPPLY (green, flashing) bad thermistor HEAT (yellow) call for heat GFEP (red) ground fault condition GFEP (red, flashing) failed GFEP test GFEP (red, flashing, rapid) GFEP test in progress GFEP Test To manually verify the operation of the ground fault circuitry, momentarily press the GFEP TEST/RESET switch on the SST. This should not normally be necessary as the SST will test the ground fault circuitry when power is applied to the unit and once approximately every 24 hours as long as power is supplied to the unit. GFEP Reset In the event that a ground fault condition is detected by the SST heaters will be turned off, if on, and heaters will be prevented from further operation until the ground fault condition has been reset. The red GFEP Fault indicator will be continuously on as long as there is power to the SST and a ground fault condition remains. The ground fault condition will be persistent and will be remembered by the SST even if the unit loses power. To clear the ground fault condition momentarily press the GFEP TEST/RESET switch on the SST. Maintenance The SST 2 does not require routine maintenance. For technical help, questions or comments concerning this product or any Environmental Technology, Inc. products contact the Customer Service Department between 8:00am and 5:00pm ET at: Voice: Fax: E-mail: 800.234.4239 (USA and Canada) or 574.233.1202 (elsewhere) 888.234.4238 (USA and Canada) or 574.233.2152 (elsewhere) helpdesk@networketi.com 22804C 12/14 (800) 234-4239 http://www.networketi.com Environmental Technology, Inc. 5 of 8

Model SST 2 Specifications General Area of use Approvals Nonhazardous locations Enclosure Protection Cover attachment Entries Material Mounting Front Panel Interface Status indicator Remote Interface Alarm relay Summary alarms Control Supply voltage Contact type Maximum Ratings Temperature Sensor Set point NEMA 4x Polycarbonate cover, machine screws 1 3/4" entry (bottom right) for NEC Class 2 sensor connections 3 1-1/16" entries (bottom left and left) for supply, load power and (right) NEC Class 2 alarm relay connections Polycarbonate Wall mounted SUPPLY (green) power applied SUPPLY (green, flashing) bad thermistor HEAT (yellow) call for heat GFEP (red) ground fault condition GFEP (red, flashing) failed GFEP test GFEP (red, flashing, rapid) GFEP test in progress Isolated SPDT 1 AMP Class 2 contact No Power Ground Fault Condition GFEP function test failure Bad or missing Thermistor P/N 22744: 40 F (4.4 C) P/N 23708: 175 F (80 C) Dead band 2 F (1 C) Sensor type Thermistor network Circuit type NEC Class 2 Lead Length 120, 208, 240 or 277 volts, single phase (automatically selected) Two Form A DPST Voltage: 277 VAC Current: 30 amps Up to 2,000' (610m) using 12 AWG 2-wire jacketed cable Up to 500' (152m) using 18 AWG 2-wire jacketed cable Ground Fault Equipment Protection (GFEP) Set point 30 ma Automatic self test Mode A: Verifies GFEP function before contactors operate Mode B: Verifies GFEP function every 24 hours Manual test/reset TEST/RESET switch on front panel Environmental Operating temperature Storage temperature Enclosure: 40 F to 130 F ( 40 C to 55 C) Std Temp (SST 2 40) Sensor: 40 F to 220 F ( 40 C to 104 C) High Temp (SST 2 175) Sensor: 40 F to 300 F ( 40 C to 149 C) 67 F to 167 F ( 55 C to 75 C) 6 of 8 Environmental Technology, Inc. http://www.networketi.com (800) 234-4239 12/14 22804C

Appendix A. SST 2 Dimensions. Model SST 2 7 7 /16" (189mm) 4 1 /4" (108mm) 1 1 /16 (27mm) Conduit Entry 1 1 /16 (27mm) Conduit Entry 3 / 8" (10mm) Ø Temperature Sensor 1 7/16" (37mm) 20' (6m) Sensor Cable, 3/16" (5mm) Ø Appendix B. SST 2 Wiring. 22804C 12/14 (800) 234-4239 http://www.networketi.com Environmental Technology, Inc. 7 of 8

Model SST 2 Appendix C. SST 2 Wiring Diagram. ORDERING INFORMATION Order Number Description 22744 Model SST 2 40 Freeze Protection Thermostat 19272 Temperature Sensor (included with 22744) 23708 Model SST 2 175 Fixed Set Point Thermostat 23846 Temperature Sensor, High Temp (included with 23708) LIMITED WARRANTY ETI s two year limited warranty covering defects in workmanship and materials applies. Contact Customer Service for complete warranty information. DISCLAIMER Environmental Technology, Inc. makes no representations or warranties, either expressed or implied, with respect to the contents of this publication or the products that it describes, and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. Environmental Technology, Inc. reserves the right to revise this publication, and to make changes and improvements to the products described in this publication, without the obligation of Environmental Technology, Inc. to notify any person or organization of such revisions, changes or improvements. The ETI logo, Snow Switch, Floorstat, Tracon, We Manage Heat, APS, RCU, CIT, GIT, SIT are registered trademarks of Environmental Technology, Inc. Copyright 2013 Environmental Technology, Inc. All rights reserved. 8 of 8 Environmental Technology, Inc. http://www.networketi.com (800) 234-4239 12/14 22804C