Smardt Oil-Free Chillers

Similar documents
Magnetic Bearing Technology: Achievements in Higher Efficiency

Chiller Manufacturer should have been manufacturing chillers utilizing magnetic bearing, oil free technology for more than 10 years.

Presented By: John Dolan, P.E.

Midea VFD Centrifugal Chiller Technology

Technical Development Program

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

Innovation for a Better & Greener Future

REVOLUTIONARY ENERGY SAVINGS

$42,000. Danfoss Turbocor Compressors Give INTERTECH PLASTICS A RESHORING ADVANTAGE. saved annually

MTW Series Modular Oil Free Centrifugal Chillers

Chapter-8 Capacity Control of Refrigeration Systems

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

Smardt vs. McQuay Comparison of Standard Options and Other Benefits < 400 tons

Water-cooled chillers with High Speed Centrifugal Compressors

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Cutting Edge Compressor Technology

Air conditioning 23XRV

Air-cooled Screw Chillers Model RTAF G Process

Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw

sm All Product Catalog

Chiller Plant Design. Julian R. de Bullet President debullet Consulting

CVGF. Water Cooled Centrifugal Chillers

All Chiller Products. Water Cooled and Air Cooled Modular Chillers Available in 208, 230, 460 & 575 Volts Application Ranges from 30 to 1,000 Tons

HVAC Water chiller selection and optimisation of operation

Screw Water Cooled Chiller SCW210

HVAC Clinic. Helical Rotary & Centrifugal Water Chillers

MLC Air Cooled Chillers MLC-FC Free Cooling Chillers MLC-AD Adiabatic Chillers

Method to test HVAC equipment at part load conditions

Product Line Introduction. Karl Zhang Technical support engineer

Series. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost

Update Dedicated Heat Recovery Chiller Technology. Don Frye. Gulf South

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Engineered for flexibility and performance

The Refrigeration Cycle. Jerry Cohen President Jacco & Assoc.

Scroll Water Cooled Chiller

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Your Chiller Solution For Efficiency And Reliability. McQuay Dual Compressor Centrifugal Chillers 160 to 2500 Tons

Liebert CW kW. Chilled Water Cooled Precision Air Conditioning For Data Centers. Precision Cooling For Business-Critical Continuity

opti-visor ultra-efficient chiller plant automation Typical specification

Variable refrigerant flow (VRF) systems

Air-Cooled MagLev Chiller Product Catalog

How to Cut Chiller Energy Costs by 30%

MEDICAL CHILLER SYSTEMS

Nirvana. Cycling Refrigerated Dryers

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

Flexible & Innovative. Cooling Solutions

APS Chiller Seminar. Don Brandt, CEM-AEE, BEAP-ASHRAE ASHRAE and IEEE Life Member 3/16/2017

Control Systems. Design & Manufacturing. Eco-Friendly. High Performance

Water-Cooled Modular Chillers. Product Data Catalog. Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X

Leadership, Innovation, Advanced Technology Synergise Here!

Trailblazer air cooled scroll chillers

Air Cooled Scroll Chiller / Heat Pump

System Drop-in Tests of R-134a Alternative Refrigerants ARM-42a and R-1234ze(E) in an Air- Cooled Screw Chiller and a Water-cooled Centrifugal Chiller

Chiller Plant Design. Application Guide AG McQuay International. Elevation Difference. Column Height When Pump Is Off

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

Parilla Thermal Storage Project Case Study. May Page 1 of 11

OIL FREE CENTRIFUGAL CHILLER

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

PACKAGED AIR COOLED Product Data Catalog

Summary Comparison of Simulation Program Features

NQ Series Portable Chillers

H EDRICK ASSOCIATES OF GRAND RAPIDS West Michigan s Factory Representative

Technical Report #3 Mechanical Systems Existing Conditions Evaluation

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

Air Cooled Packaged Systems AIRAH Back to Basics

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

Optimised for high ambient operation (up to 55 C ambient) EWAD-MZ. Air cooled chiller

YORK AMICHI SERIES AIR-COOLED DC INVERTER SCROLL CHILLERS AND HEAT PUMPS

unico turbo fl kw R134a MICRO CHANNEL OIL FREE INVERTER FLOODED CLASS E C Energy Class RCGROUP SpA fiftycoolyears C_GNR_0113

Refrigerant Type Heat Recovery Unit for Temperature & Humidity Control Room

2. CURRICULUM. Sl. No.

XStream Water-cooled screw chillers and Water/Water Heat pumps

AC SYSTEM CONFIGURATION- CENTRAL CHILLER PLANT

commercial refrigeration products

Centrifugal Chiller. GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series

RECORD SUBMITTAL COVER SHEET

Water Cooled Flooded Chiller Product Data Catalog. Made in U.S.A.

Integrated VarIable refrigerant flow ahu/pau (r410a)

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

Symbolic photo. T CLASS WATER COOLED CHILLERS Oil-Free Centrifugal Chiller

Be sustainable while protecting your business

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

Life-Cycle Energy Costs and Greenhouse Gas Emissions for Gas Turbine Power

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Understanding Head Pressure Control. Walter H Langille, M.A.Sc., P.Eng Sales Engineer KeepRite Refrigeration

On Balance: Heat Rejection Control a Packaged Solution

BES-TECH TECHNOLOGY & SYSTEM INTEGRATION

Energy Efficiency Through Waste Heat Recovery. Heat Recovery Centrifugal Chillers and Templifier Water Heaters

Centrifugal, Magnetic Bearing, Compressor Water Chiller Model WMC-035T, 110 to 175 Tons

YORK AMICHI SERIES AIR-COOLED DC INVERTER SCROLL CHILLERS AND HEAT PUMPS

SUBCRITICAL & TRANSCRITICAL SYSTEMS

Improving Cold Chain Competitiveness with Danfoss Energy Efficiency Solutions.

Centrifugal Compressor Water Chillers Catalog 605 Models WSC, WDC, WCC, HSC

19DV Back-to-Back Centrifugal Liquid Chiller with PUREtec TM Refrigerant and Greenspeed TM Intelligence

DC Inverter Smart VRF Products(R410A)

PRODUCT RANGE: ROOFTOP PACKAGE

Transcription:

Smardt Oil-Free Chillers

Company History in Brief Turbocor compressor invented in Australia in 1993 Turbocor was relocated to Montreal in 1999 Danfoss forms 50/50 partnership in 2004 Smardt was founded in 2004 to manufacture chillers Product range grows from 60 to over 800 tons in 2005 Air cooled models extend from 60-250 tons ARI Certifications were completed in 2007 Over 7,000 compressors, 1,000 chillers installed NEW 220 ton compressor. 1,320 ton chiller slated for 2008

The Quantum Group World Leaders Worlds largest chiller group specializing in Turbocor oil-free centrifugal technology, heat exchanger innovation and Kiltech Control Systems.

The Remarkable Turbocor Compressor 100% Oil Free eliminates oil system maintenance costs. R134a Refrigerant meets Montreal protocol and is not subject to phase-out. Magnetic Bearings eliminate frictional losses. One moving part assures long service life. Unmatched Efficiency as low as.31 kw/ton IPLV. Low In-Rush Current reduces installed cost and peak load. Lowest Noise-Only 72 dba.

The Turbocor Compressor Synchronous brushless DC motor Inverter speed control Soft-Start (<2amps Inrush) 2 stage centrifugal compressor Pressure and temperature sensors Inlet Guide Vanes Motor and bearing control

VFD and Inlet Guide Vane Operation The Compressors speed adjusts automatically to match the load and current operating conditions so that optimum efficiency is gained. Primary capacity control is done using the onboard VFD and only use the Inlet Guide Vanes to supplement VFD controls. IGVs prevent surge conditions at low turndown. IGVs normally operate at the 110% position. The slower the compressors, the greater the efficiency. As speeds is reduced, energy consumption is reduced by the cube. Speed Energy 3

The Magnetic Direct-Drive System Magnetic bearings and sensors keep the shaft properly centered and positioned at all times. The rotor shaft is held in position with ten separately controlled electro magnetic cushions which continually changes in strength to keep the shaft centrally positioned. The shafts position is monitored with 10 sensor coils who s signal is fed back to a digital controller. Movements of less than.00002 are sensed and adjustments are made accordingly. Back up carbon or roller bearings are fitted to catch the shaft and prevent damage should a control or bearing failure occur. Shaft is monitored and positioned 100,000 / sec.

What Happens with a Power Outage? In the case of a power outage, the compressor is fully protected. Within 0.5 of a micro-second, the motor becomes a generator which then feeds power to the various controls and bearing actuators during a controlled coast-down. The onboard capacitors have adequate power to fully support the bearing system during the switch from motor to generator mode. Capacitors are replaced every five years. After the compressor comes to a complete stop, the rotor de-levitates normally onto touchdown bearings. Carbon or roller touchdown bearings are also used as a back up bearing system to act as a cradle for the rotor during the off-mode. The system then determines if normal power is restored, if YES, the shaft levitates. If there is a call for cooling, the rotor will then begin to rotate. The entire cycle from loss of power to normal operation takes about 3-5 minutes.

Compressor Sizes and Uses Model Capacity IPLV Turndown TT300 90 tons.38 12 tons TT400 140 tons.33 65 tons TT500 220 tons.31 TBD Chilled Water Range 25F to 60F 134a limited Condenser Water Range 50F to 90F Ambient Range 10F to 108F Heat recovery to 120F Rule of thumb 12 degrees between LWT and ECT

The Magnetic Bearing System Permanently magnetized shaft does not require electrical power for operation. 97% energy efficient Uses 0.5% of the energy required for conventional bearings for same service Eliminate high mechanical friction losses Eliminate oil-related heat transfer losses Eliminate cost of oil management systems (controls and hardware) Increase equipment life through elimination of wear surfaces

Compact Size - Easy to Service 125 HP motor is in the foreground. 150 HP Turbocor permanent magnet motor behind. Variable-speed, magnetic bearing and cooling controls.

High Capacity Smaller Size

Oil-Free Eliminates Piping Complexity No need for elaborate piping designs compared with oil management systems. No traps and risers Lower installed costs Eliminates leak sources Enables centrifugal chiller with remote condenser to be placed at distance.

Lowest Cost of Service Annually check electronics for tight connections No oil service or oil disposal - EVER. Replace capacitors every five years

Automatic Bearing Compensation This compressor continued to operate even though this hole saw slug was embedded in the 1st stage impeller. The compressor is not designed to pump hole saw slugs, however when faced with this problem, the auto-balance feature was robust enough to handle the challenge. The compressor continued to operate at 35,000 rpm with this imbalance.

Lowest Noise and Vibration Levels Best in Class low sound levels. No moving mechanical part touches any part of the housing or frame to transmit acoustic energy. Tested at 72 dba at 1 meter with no sound attenuation. Screw compressors, by comparison, are approximately 80 dba or higher. Vibration is essentially non-existent. The chiller with 5 compressors operating at full speed only produces 75 DB of sound at 10 feet., about the sound level of your television.

Turbocor Monitoring Software

Turbocor Monitoring Software

Why Is Smardt So Compelling?

Why Is Smardt So Compelling?

The Dramatic Effects of Oil Oil affects heat exchanger efficiency Oil causes 50% of downtime and cost

The Dramatic Effects of Oil Percent Oil ASHRAE 601 sampling shows average percentages of oil present in chillers Efficiency loss in heat exchangers account for substantial operation costs Percent Oil

The Dramatic Effects of Oil Efficiency loss - % In the ten chillers tested in the ASHRAE study, the average overcharge of oil in the system was 12.88%, this equated to an average energy loss of about 21% Percent of oil

Smardt Chillers Compared with Screws ARI 550/590-1998 Conditions Leading Screw WATER COOLED Smardt Chiller with TT300 WATER COOLED Load ECW F/C LCHW F/C SST F/C SCT F/C COP kw/ton SST F/C SCT F/C COP kw/ton 100% 85/29.5 44/6.7 42/5.6 98/36.7 5.33 0.64 42/5.6 98/36.7 5.56 0.63 75% 75/23.9 44/6.7 42.3/5.8 89.6/32 5. 73 0.6 42.3/5.8 85/29.5 7.31 0.48 50% 65/18.3 44/6.7 42.5/5.9 89.6/32 * 5.49 0.64 42.5/5.9 72.2/2.2 11.38 0.30 25% 65/18.3 44/6.7 42.8/6. 89.6/32 * 4.11 0.845 42.8/6 70/21.1 10.86 0.32 IPLV COP kw/ton 5.4.65 9.55 0.36 Conclusion The Smardt Chiller using the Turbocor TT300 compressor is 45% more efficient than the leading screw compressor

Smardt Chillers Compared with Screws ARI 550/590-1998 Conditions Leading Screw AIR COOLED Smardt with TT300 AIR COOLED Load Air F/C LCHW F/C SST F/C SCT F/C COP kw/ton SST F/C SCT F/C COP kw/ton 100% 95/35 44/6.7 35.5/2 122/50 3.19 1.10 35.5/2 122/50 3.08 1.13 75% 80/26.7 44/6.7 36.5/2.5 104/40 4.20 0. 83 36.5/2.5 104/40 4.44 0.79 50% 65/18.3 44/6.7 37.5/3 86/30 5.26 0.69 37.5/3 82.5/28 7.23 0. 48 25% 55/12.8 44/6.7 38/3.5 86/30 3.98 0.88 38/3.5 66.2/19 9.77 0.35 IPLV COP kw/ton 4.6 0.76 6.32 0. 55 Conclusion The Smardt Air Cooled Chiller using the Turbocor TT300 compressor is 29% more efficient than the leading screw compressor

Standard 90 Ton Compact Chiller Oil-Free design eliminates frictional losses and high cost. Lowest IPLV in the industry. Variable-speed Drive. Flooded evaporator for thermal buffer and close approach. Cleanable condensers. NEMA 1 Panels Standard. Kiltech Controls Standard Marine Water Box Option. FATMAX Option. Ashrae 90.1 thoughts

Standard Design 350 Ton Chiller Standard design uses stacked heat exchangers Split systems are available. Multiple Circuits available. NEW Condenserless and Condensing Units available SOON. NO Oil acid burnout.

Multiple Compressor Chillers Up to six compressors in one circuit Provides the ability to use the entire heat transfer surface even when using few compressors, thereby ensuring very close approach temperatures.

NEW Split-able Shell Chiller Shell can be split to transport short sections into equipment rooms. Enables the efficiency and lower cost of single-circuit while enabling transport through doors, elevators and around corners Results in Dual-Circuits Components can be Shipped-Loose

High-Efficiency - Multiple Compressors Staging compressors must reduce head pressure to add compressors. Can affect set point temporarily. More noticeable with more compressors. Process applications may require hot gas bypass at each compressor to assure steady set point. Thermal mass tanks can be helpful for datacenters, museums, critical temp applications.

Compact Parallel Modular Approach Enables transport of compact, low capacity modules and assemble high capacity systems in the equipment room. Common headers can allow optional variable flow systems while ensuring correct fluid velocities. Isolation valves required for stepped flow Set Point Reset required for constant flow because of effect of mixing.

Air Cooled Chillers 90 to 250 Tons Up to three compressors and 12 fans 250 tons now. 350 tons 2008. Minimum compressor starting temp 32 degrees. Maximum 108 ambient.

Air Cooled Chillers 90 to 270 Tons Standard two-speed fans. Optional variable-speed fans with low-noise and self-contained VFD. Can significantly reduce overall energy usage. All condenser coils are coated. Options Thermoguard and ElectroFin. Evaporative pre-cooling systems show savings of 30% compared with normal air-cooled operation. To 125 degrees F.

ASME Heat Exchanger Manufacturing Smardt makes its own heat exchangers Group buying power, proven designs Superior, reliable performance Precise liquid controls.

Advanced Engineered Components Smardt makes its own heat EXV. 6,000 Step design assures correct refrigerant metering under every condition. Used for expansion and load-balancing requirements. Precisely controls liquid level for increased system stability. NOT a fixed orifice design. Smardt makes its own Discharge Check Valve. Industrial design provides highly reliable seating and lower pressure drop. Solves refrigerant reverse direction issues. SUPERIOR & RELIABLE OPERATION

Advanced, Easy to Use Chiller Controls

Advanced, Easy to Use Chiller Controls Real-Time Trending Most Comprehensive

Compressors and Heat Exchangers Developed from the ground up using Turbocor performance maps and optimized with proprietary heat transfer technologies. 3rd Order Trend Surface ( zp),( x1, x2, Y)

Control System Highlights Easy to use graphical touch-screen interface. Proven compressor performance maps are self-contained. Monitors 150 compressor and flow control parameters. Adjusts compressor speed and Inlet Guide Vane position in real-time to precisely match system output to demand input. Multiple layers of operational safety protect compressor. Embedded Web & FTP Servers for remote access, diagnostics & control. System uses advanced algorithm that can adjust evaporator flow rate, condenser flow rate and remote tower fan speed. Provide a complete, zero-loss heat transfer system from cooling demand to heat rejection - at the lowest possible kw consumption.

Control System kw Optimization

Smardt Control System Advantages Up to 18% better performance at part load Real time cooling capacity estimation Real time efficiency estimation Real time power analysis Increased load stability Predictable / repeatable performance Real-time compressor staging optimization Variable-speed plant integration

Features of Smardt Controls Utilizes internal compressor staging optimization algorithms to precisely match total system output from demand to final heat rejection. Uses the DDC network to coordinate the operation of multiple system components to optimize overall system operation. Many can be performed right on the chiller. Provides control based on adaptive methods rather than static temperature & pressure set-points. Permits equipment to operate as close as possible to its natural curve at part loads.

NEW CPECS Plant Control System CPECS - Central plant energy control system

CPECS - Features Complete packaged central plant variable speed system. Optimized control specifically designed for SMARDT/Powerpax chillers Chilled water pump duty standby capability Condenser water pump duty standby capability Tower fan duty standby capability. Web monitoring Plant kw/ton (COP) monitoring Chiller kw/ton (COP) monitoring Battery backed up redundant controller BAS communication protocols easily handled Lon, BacNet and Modbus Rapid payback on investment typically under 3 years for new or existing chiller. One year data logging of all major variables. Multiple chiller optimized sequencing Chiller isolation valve control Chilled water decoupling valve control Multiple cooling tower isolation valve and sequencing control Monitoring of up to 4 critical zones (temperature and differential coil pressure) Complete override capability Plant error condition monitoring Choice of variable speed drives Yaskawa or ABB Direct communications to all drives

Smardt Training and Certification Conducted by those most knowledgeable in Turbocor technologies and application nuances. Classes in Montreal, Florida and California Includes Compressor, Controls and Chillers

Smardt Variable Speed Factors Power is proportional to the speed cubed To achieve power reduction, the speed of fans, pumps and compressors should be reduced at lower loads. Emerging VFD plant controllers optimize the technology. Flooded designs with water in tubes can limit flow range due to velocity and laminar flow issues. DX can be better solution in some applications, but with efficiency loss. Cooling tower selections optimized for lower temp and flow. Can increase installed cost yet reduce operational costs.

Variable vs Constant Speed While Constant Speed Chiller Efficiency is nearly constant between 60% & 100% loading, the Efficiency of Variable Speed Centrifugal Chillers increases dramatically as load falls in that range. The Efficiency of Variable Speed Centrifugal Chillers is more significantly improved by the Reduction in Condensing Water Temperature down to 50F. Ideally provide condenser water relief and set point reset in real time by controlling tower fan and condenser pumps.

Recent Application Notes Heat Recovery 118 F maximum. Special high-lift compressor required. Only works with TT300, no TT400s. New 120 ton TT350 high-lift compressor to be introduced soon Controller has settable minimum flows to avoid laminar conditions. New Danfoss Operating Envelope. 25 F min at 25% max glycol. Staging relief valves required for process applications to increase temperature stability. Also needed for most glycol and low unloading. Surging can cause extremely high temps at impeller. Caused by pressure ratio too high, low charge, miss-set EXV, low suction.

Recent Application Notes NEW Johnson controls N2 interface. Factory run tests now available to 270 tons for water cooled and air cooled to 150 tons. Glycol applications above 25% may require DX, not flooded design. Differential temp for TT300 is @ 7-8 F. 10-12 F for TT400. This is the difference between the entering condenser and leaving chilled water. NEW product range to be released this month, wider range. No 5-6 compressor TT400s until June 1 tube exchangers in R&D. NEW web-based software BETA now in testing. Field use Q2.

San Diego Case Study Before and After $175,000 annual energy savings $423,000 implementation cost $205,000 Utility Rebate

Example Multiple Compressor System Lowest kw per ton in energy usage. Single flooded evaporator circuit assures lowest approach temperature. Provides compressor redundancy.

HVAC vs Process applications R134a limits use in process. Can provide chilled water temps to about 25 degrees F. No Ice-Rinks YET. High reliability and compressor redundancy. Data Centers can take advantage of condenser water relief not reduced load. R&D data center modules, DX racks, refrigerant distribution

Example Air-Cooled Chiller Systems Models from 90 to 250 tons Operates well in medium-hot ambient

NEW 38,000 Square Foot Factory Heat exchanger manufacturing Air-cooled chiller manufacturing Room to expand with rapid growth

Why Chose Smardt and Turbocor? More Experience than Anyone Widest Product Range to Meet Needs Lowest Energy Consumption Reliable - Lowest Maintenance Cost Easily Serviced with Advanced Controls Interfaces with Most BMS Systems

Why Chose Smardt and Turbocor? International Service & Support Global business functions & documents Always One-Step-Ahead Superior Custom Engineered Components Advanced Web Based Tools Lowest Total Cost of Ownership

Why Chose Smardt and Turbocor? ASHRAE Expo Energy Innovation Award Canadian Energy Award Frost & Sullivan

Contacting Smardt Smardt, Inc. 1800 Trans Canada Highway Dorval, Quebec H9P 1H7 Phone: (514) 426-8989 Fax: (514) 416-5757 www.smardt.com President: Roger Richmond-Smith Technical Support: Jeremy Ouellette, Esteban Ochando Business Development: Jackson Ball