Indirect Fired Water Heater

Similar documents
Light Duty Commercial Electric Water Heater

Commercial Electric Water Heater Gallon Capacity, up to 58 KW in all Three Phase Voltages, Over 6 KW in all Single Phase Voltages

Shipboard Electric Water Heater

Shipboard Electric Water Heater

Shipboard Electric Water Heater

Heat Pump Water Heater

Tepid Water Delivery System

Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW

PROVIDES TEPID WATER FOR EMERGENCY SHOWER

Semi-Instantaneous Indirect Fired Water Heater

ASME Packaged Indirect Fired Water Heater

ASME Packaged Electric Water Heater

COMMERCIAL CONDENSING GAS WATER HEATER GALLONS, 55,000 BTU/HR 94% THERMAL EFFICIENCY

COMMERCIAL CONDENSING GAS WATER HEATER GALLONS, 55,000 BTU/HR 94% THERMAL EFFICIENCY

Packaged Steam Fired Water Heater

Packaged Semi-Instantaneous Steam Fired Water Heater

Tankless On Demand Electric Water Heater

Packaged Instantaneous Circulation Heater Full KW Selection In All Voltages, Single or Three Phase

Tankless Electric Water Heater Available 3-27 kw in Single Phase Voltages

SECTION DOMESTIC WATER HEATERS

Tankless Electric Water Heater Available up to 54 KW in Single or Three Phase Voltages

High Capacity Instantaneous Steam Fired Water Heater

ASME and Non-ASME Storage Vessels

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR COMMERCIAL INDIRECT POWERED WATER HEATER

DI/RO GAS TANKLESS WATER HEATER

OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D

96% COMMERCIAL INDUSTRIAL HEATER. Condensing Gas Water Heating System. Thermal Efficiency

OPERATING AND MAINTENANCE MANUAL FOR COMMERCIAL ELECTRIC WATER HEATER. ELECTRIC HEATER COMPANY BASE MODEL SH and H

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

Easy Installation & Service

INSTALLATION AND OPERATING INSTRUCTIONS

EHB Series. STONESTEEL Commercial Electric Water Heaters Individually Mounted Elements Vertical or Horizontal CEMLINE CORPORATION

DHW Tanks Indirect Tanks for Domestic Hot Water. New! Single coil tanks with electric element

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR POINT OF USE STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL PS

Technical Data Manual Model Nos. and pricing: see Price List

Portable CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

Stainless Steel Indirect Water Heaters

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR COMPACT POINT-OF-USE ELECTRIC WATER HEATER

OPERATING AND MAINTENANCE MANUAL FOR BOILER WATER OR HIGH TEMPERATURE HOT WATER (HTHW) POWERED WATER HEATER

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

MAXIM. Power Combustion Storage Water Heater Gas, Oil or Combination Gas/Oil. 199 to 1200 MBH 125 and 250 Gallon Tanks 15-year Warranty. PVI.

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

THE HARD WATER WATER HEATER

Portable C2N Series - Light Industrial Heaters Tankless Water Heating Solutions

Dunkirk H 2 O. Innovative. Efficient. Dependable. Dunkirk.

Portable C1N Series - Light Industrial Heaters Tankless Water Heating Solutions

SNA-SKID Series - Preassembled Safety Shower Heater Skid Tankless Water Heating Solutions

OPERATING AND MAINTENANCE MANUAL FOR STEAM FIRED WATER HEATER. ELECTRIC HEATER COMPANY BASE MODEL ST and STH

EB-M*-** Midsize Electro-Boiler BL509. EB-S-**/EB-WX-**-2 TS Standard Electro-Boiler BL506. EB-CX-** TS Commercial Electro-Boiler BL508

TABLE 1 Electrical Specifications

Control and power circuit fusing to meet N.E.C.

STORAGE TANK INSTALLATION and OPERATION MANUAL

INDIRECT FIRED WATER HEATERS

Suggested Specifications Prestige Excellence 110

SECTION ELECTRIC WATER HEATERS

INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER. Compact Design. High Recovery. Energy Efficient. Stainless Alloy Construction

Immersion Heaters. Screw Plug Immersion Heater

COBREX. Semi-Instantaneous. Steam-Fired Domestic Hot Water Generator. Up to 7000 MBH 150/ 175/ 215 Gallon Tank 25-year Warranty. PVI.

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

TABLE 1 Electrical Specifications. Phase

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water

OPERATING AND MAINTENANCE MANUAL FOR PACKAGED ELECTRIC TEPID WATER HEATING SYSTEMS BASE MODEL ESS

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

SERVICE MANUAL. Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models

COMMERCIAL SPACES WATER HEATING SOLUTIONS WATER HEATERS

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Electro-HELPS XV ELECTRO-BOILER SPECIFICATIONS. A complete product line to fi t all your application needs. Made in USA

Keltech SNA-Series - Safety Shower Heaters Tankless Water Heating Solutions

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

C D E F. Tubular Industrial Process Circulation Heaters. Circulation Heaters. View Product

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Installation & Operation Manual Models: TSU

Precision Storage Vessels ELECTRIC WATER HEATERS

Tubular Industrial Process

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Taco 00 Series Cartridge Circulators

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Discontinued. SN Series - Safety Shower Heaters Tankless Water Heating Solutions. Standard Equipment. Construction. Code Compliance and Certifications

Stainless Steel Unvented Cylinders

=Classic range= Classic range technologies. Magnesium anode. Sheathed heating element

Water Heaters. Solar Applications

Technical Data Manual Model Nos. and pricing: see Price List

Stainless Steel Indirect Water Heaters

Advanced Heating & Hot Water Systems. Stainless Steel Indirect & Storage Tanks

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

199,000 to 4,000,000 Btu/h 150 to 4500 Gallons Storage

CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

Owner s Manual Therma-Stor II Heat Recovery System

SECTION ELECTRIC WATER HEATERS

INSTALLATION AND SERVICE MANUAL

ARTESIAN 220 & 340 Instantaneous Indirect Water Heater By Dunkirk Boilers INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL

SPH Series. Vertical Packaged Storage Boiler Water Fired Plate Heat Exchanger Water Heaters CEMLINE CORPORATION

SECTION PLUMBING EQUIPMENT

INSTANT-FLOW C-MICRO WATER HEATER

DIVISION FINNED WATER-TUBE BOILERS

INSTANT-FLOW C-MICRO WATER HEATER

TABLE 1. Specifications: Dimensions: 6¼ x 9 5/8 x 2 ¾

Pipe Thread Heaters. Construction Features. Star Electric to Order Call " 2-1/2" Pipe Thread Heaters

TURBOPOWER. Non-Condensing Gas, Oil or Combination Gas/Oil Storage Water Heater. 199 to 4000 MBH 150 to 4500 Gallons Tanks 25-year Warranty. PVI.

Transcription:

Indirect Fired Water Heater 35-119 Gallon Capacities Features Heavy Duty Construction Hydrastone cement lining provides long tank life Copper-silicon tappings cannot rust or corrode High impact composite jacket cannot rust or corrode and eliminates damage High Efficiency 2" thick polyurethane foam insulation reduces standby heat loss providing the industry's highest efficiency heater. Advanced Heating Heating coil can be easily removed for simple maintenance Heavy gauge copper fin tube coil provides maximum heat transfer TransFlow Applications Residential Industrial Facilities Commercial Buildings Office Buildings Schools NO GLASS LINING TransFlow (Top Mount T T70C Shown) The Hubbell TransFlow Water heater uses Boiler Water as the source for heating potable water. Utilize Existing Boiler Water Supply To Make Hot Water The Hubbell T water heater utilizes an existing supply of boiler water to heat domestic potable water. The Transflow model storage tank is fitted with a specially designed, high efficiency heating coil which transfers heat from the boiler water to the domestic water in the tank. It s advanced design has no moving parts and does not require any electrical connections, while the high quality materials used in construction of its tank and heating coil ensures long service life. When you specify and install a Hubbell Transflow water heater, you will have confidence in knowing that the owner will be provided with a quality product that is a trouble-free and long lasting source for hot water. A Highly Efficient and Long Lasting Water Heater

TransFlow Water Heater Specifications Tank: Capacities: Orientation: Size: Tank Rating: Type: Material: Rating: Approvals: Jacket: Color: Hydrastone Cement Lined Steel 35 thru 119 Gallons Vertical 3 /4" Hose Connection 150 psi WP, 300 psi TP Removable Copper Fin Tube 150 psi WP, 300 psi TP culus, AHRI, IBR High Impact Colorized Composite White and Black Operation Voltage: Switching Relay: Temperature Range: 110-160 F Differential: Tank Warranty (Residential) Top Mount : Side Mount : Tank Warranty (Commercial) Top Mount : Side Mount : 24 Volt AC/DC (Constant) S.P.S.T, 120 Volt, 10 Amp max. 2-20 F (Adjustable) 10 Years 7 Years 5 Years 3 Years Standard Equipment 1 /2" thick Hydrastone cement lined steel tank All copper-silicon non-ferrous tank openings Removable heating coil High efficiency copper fin tube heating coil Immersion adjustable electronic thermostat to control the flow of boiler water through the heating coil ASME rated temperature and pressure relief valve set at 150 psi, 210 o F, 200,000 BTU max 2" thick polyurethane foam insulation meets or exceeds the requirements of ANSI, ASHRAE, IESNA 90.1-2007 High impact colorized composite protective jacket Pressure Drop Chart Optional Equipment 1. 1 1 /2" Male NPT inlet and outlet water connections 2. Double wall copper heating coil with a leak detection port 3. Integrally welded seismic attachment points 4. Electric back-up heating element in various wattages in single or three phase voltages (consult factory). 5. Bulb and capillary mechanical thermostat (100-240 F) to accept 24-600 VAC operation voltage; SPST switch 120 Volt (16 Amp), 208 Volt (9 Amp), 240 Volt (8 Amp). Please note: Optional equipment may impact overall dimensions and weight. Please request submittal drawing from factory. 2

SIDE MOUNT COIL Outline Dimensions 45 o T&P Relief Removable Heat Exchange 45 o Hot Water Outlet Combination Cold Water and Sensor Side Mount 10 o Hot Water Outlet 1" Protective Jacket T&P Relief Optional Additional Tank Cross Section Optional Additional Combination Cold Water and 24" Withdrawal Space Side View 2" Foam Insulation Immersion Controller Boiler Water Heating Boiler Water Outlet Front View A B Hydrastone 1 /2" Steel Pressure Vessel C D Dimensions Standby Heat Loss F/Hour Diameter Height A Dimensions (Inches) B C T&P D / Outlet Size (NPT) TS65 65 0.44 26 48 8 10 14 40 3/4" 308 TS80 80 0.41 26 58 8 10 14 51 3/4" 338 TS80C 80 0.41 26 58 8 10 14 51 1-1/2" 340 TS120 119 0.39 28 69.25 8 11 17 62 3/4" 420 TS120C 119 0.39 28 69.25 8 11 17 62 1-1/2" 425 Shipping Weight (Lbs) Heating Selection Chart with Recovery Ratings Position TS65 65 Side TS80 TS80C TS120 TS120C 80 Side 119 Side Type No. Connection Size (NPT) 1st Hour Rating Continuous Demand Rating (Gal/Hr) Boiler Water Flow Rate (GPM) Single Wall 20S 1" 295 235 13 Double Wall 10D 3/4" 142 82 11 Single Wall 20S 1" 307 235 13 Double Wall 10D 3/4" 154 82 11 Single Wall 20S 1" 339 235 13 Double Wall 10D 3/4" 186 82 11 Recovery ratings based upon the supply of 200 F boiler water to a single heating coil to heat domestic potable water from 50-140 F. For 180 F boiler water reduce recovery ratings by 25%. Recovery ratings based upon one heating coil installed in tank. For additional coils, use the continuous demand rating. 3

TOP MOUNT COIL Hot Water Outlet and Relief Heating Outlet (To Boiler) Outline Dimensions 3/4" and Outlet Top View Heating (From Boiler) Cold Water Immersion Thermowell 3/4" Hot Water Outlet T&P Relief 8" C E Withdrawal Space Foam Insulation Tank Cross Section Hydrastone 1 /2" Steel Pressure Vessel A Heating (From Boiler) Hot Water Outlet Heating Outlet (To Boiler) Relief 1 1/2" and Outlet TT70C Only 10 o Top View 30 o 20o 30 o Thermowell T&P Relief Immersion Thermowell A 3" D C B Foam Insulation Tank Cross Section Hydrastone 1 /2" Steel Pressure Vessel Dimensions Standby Heat Loss F/Hour Diameter Height 1 1/2" MNPT Cold Water Dimensions (Inches) A B C T&P D Relief Size / Outlet Size (NPT) Withdrawal Space E TT35 35 0.72 22.75 39 8 Top 14 Top 3/4" 3/4" 36" 185 TT50 50 0.56 26 40 8 Top 14 Top 3/4" 3/4" 36" 238 TT70 70 0.45 28 46.5 8 Top 14 Top 3/4" 3/4" 41" 290 TT70C 70 0.45 28 46.5 8 8 14 38.5 3/4" 1-1/2" 41" 290 Shipping Weight (lbs.) Heating Selection Chart with Recovery Ratings Position TT35 35 Top TT50 50 Top TT70 70 Top Number Type Connection Size (NPT) 1st Hour Rating Continuous Demand Rating (Gal/Hr) Boiler Water Flow Rate (GPM) 15S Single Wall 3/4" 230 203 6 15D Double Wall 3/4" 124 94 4 15S Single Wall 3/4" 250 214 6 15D Double Wall 3/4" 142 94 4 16S Single Wall 3/4" 335 271 6 16D Double Wall 3/4" 175 111 4 TT70C 70 Top 19S Single Wall 1" 385 321 13 Recovery ratings based upon the supply of 200 F boiler water to the heating coil to heat domestic potable water from 50-140 F. For 180 F boiler water reduce recovery ratings by 25%. 4

Heating Design Top Mount Plumbing connections located in flange simplifies installation and improves tank longevity O-ring gasket design provides reliable and trouble free sealing Heating surface area predominately located in the coldest part of the tank for greater temperature differentials resulting in significantly improved heat transfer Incoming cold water is distributed directly over the heating coils thereby significantly reducing mineral build up. Counter flow design increases heat transfer efficiency and hot water output. Top Mount Typical Installation Installation Key Shut-off Flow Check Circulation Pump Union T&P/Relief & Brass "T" Hot Out to Fixtures Residential Boiler Supply Min. 3/4" Zone Expansion Tank Dielectric Union Air Scoop with Expansion Tank Cold In Recommended Min. 3/4" Hot Out to Fixtures Min. 1-1/2" Commercial Boiler Supply Commercial with Additional Hot Out to Fixtures Min. 1-1/2" Hot Out Min. 1-1/2" Boiler Supply Min. 1-1/2" Cold In Min. 1-1/2" Recommended Cold In Min. 1-1/2" Recommended 5

SIDE MOUNT TOP MOUNT T S Number Designation TS Step 1 : TS= Side Mount Step 2 : Gallons 65-119 Step 3 # s Upper: 0,1,2 Step 4 # s Lower: 1,2 T T Number Designation TT Step 5 #: See Selection Chart Step 6 KW Selection: 1.5-20 KW Complete this section only when specifying a backup electric heating element. Complete this section only when specifying a backup electric heating element. Step 7 Voltage / Phase / Hz: A = 120-1-60 RS = 208-1-60 S = 240-1-60 W = 277-1-60 T4S = 480-1-50/60 Step 8 No. Elements: 1 = Upper Position Only (Single) 2 = Upper & Lower Position (Dual) Step 1 : TT= Top Mount Step 2 : Gallons 35-70 Step 3 #: See Selection Chart Step 4 KW Selection: 1.5-20 KW Step 5 Voltage / Phase / Hz: A = 120-1-60 RS = 208-1-60 S = 240-1-60 W = 277-1-60 T4S = 480-1-50/60 Step 6 No. Elements: 1 = Upper Position Only (Single) 2 = Upper & Lower Position (Dual) Master Specification: TransFlow Job Name engineer Representative contractor GENERAL Provide a quantity of Transflow water heater(s) No. as manufactured by HUBBELL Electric Heater Co., Stratford, CT. The entire unit is to be complete with all operating controls and requires only plumbing and electrical service connections. The tank shall be all welded steel commercial construction designed for 150 psi working pressure and contain gallons of storage. The tank shall be lined with seamless Hydrastone cement to a minimum thickness of ¾"on 100% of all interior tank surfaces and does not require any type of anodic protection. The tank shall be designed and fabricated with non-ferrous copper-silicon threaded tappings and non-ferrous inlet and outlet piping for maximum corrosion resistance. Steel tank tappings will not be acceptable. The entire tank is to be insulated with a minimum of 2" thick polyurethane foam insulation and exceed the latest ASHRAE standard for stand-by heat loss. The complete heater shall be supplied with a high impact colorized composite protective jacket which cannot rust or corrode and does not require painting. The cold water inlet shall be ¾" Female NPT ( Optional Specification: 1 1 /2" Male NPT ) and include a non-corrosive strata-flow diffuser which prevents incoming cold water from mixing too rapidly with hot water in the tank. A ¾" hose connection drain is supplied. The hot water outlet shall be ¾" Male NPT ( Optional Specification: 1 1 /2" Male NPT ). A separate Female NPT tapping is to be provided for relief valve installation. An ASME rated automatic reseating combination temperature and pressure safety relief valve set at 150 psi and 210 F shall be factory supplied. HEATING COIL The tank shall be fitted with a heating coil which transfers heat from the boiler water to the domestic water. Boiler water shall be in the tubes and domestic water in the tank. The heating coil shall be of single wall ( ISO 9001:2008 ISO Optional Specification: double wall ) copper fine tube construction for maximum heat transfer efficiency and coil longevity. The coil shall be fully removable from the tank to allow for periodic inspection and maintenance without the need to move or lift the storage tank from its installed position. Back-Up Electric The water heater will be supplied with a back-up heater. The back-up heater shall be a single electric immersion heating element ( Optional Speci ication: 119 gallon models only: a dual upper and lower element) rated at KW each and designed to operate at volts phase Hz with all necessary operating controls factory mounted, wired and tested. The heating element(s) shall be copper or incoloy sheath electric immersion type sized to obtain the rated recovery. Water temperature shall be controlled through an adjustable 110-170 o F snap action surface thermostat. An over-temperature manual reset Hi-Limit shall be factory installed to disconnect all conductors to the heating element in the event of an overtemperature condition in the pressure vessel. THERMOSTAT The tank shall be fitted with an immersion 110-160 F adjustable electronic temperature controller to control the flow of boiler water through the heating coil. The temperature controller requires a constant 24 volt power supply to operate. The switching relay is a S.P.S.T. 120 volt 10 Amp Max relay which opens or closes the control circuit to the circulation pump or zone valve (by others) in order to regulate the flow of boiler water through the coil and thereby maintain the desired water temperature in the tank. WARRANTY The water heater manufacturer shall warranty all components against defects in workmanship and material for a period of one (1) year from date of start-up and the pressure vessel including the heating coil for five (5) years from date of start-up, (residential applications seven (7) years) provided that the unit is started within three (3) months of date of shipment and installed and operated within the scope of the tank design and operating capability. Each water heater shall be shipped with a complete set of installation and operating instructions including spare parts list and approved drawings. Committed to continuous improvement... Continuing research results in product improvement; therefore specifications are subject to change without notice. For the most updated information, consult the factory directly. Made in the U.S.A. The Electric Heater Company P.O. Box 288 Stratford, CT 06615-0288 Phone: 203-378-2659 Fax: 203-378-3593 info@hubbellheaters.com www.hubbellheaters.com Rev C