Isolators, RABs and Mobile Clean Rooms in Aseptic Processing. Gary Partington Walker Barrier Systems

Similar documents
BARRIER TECHNOLOGY RABS & ISOLATORS FOR ASEPTIC PROCESSING

The Logistics of Filling and Freeze Drying using Multiple Isolators. The use of isolator technology to fill and lyophilize pharmaceuticals

Aseptic Barrier Systems

A company for the design and manufacture of cleanroom equipment

CBC s Inspection Findings and Possible Remedies Thereto

Factory & Hospital hygiene, Chap 21(7 th edition) Principles of GMP, Chap 23 (8 th edition )

The DECON RTP canister VHP decontamination system

Fedegari Aseptic Technology Integration: Case Study. Sergio Mauri, Director, Global Integrated Projects

Biological Safety Cabinets. Presented by Mr. Rene Soetens President

Rapid transfer port technology

INDEX 45 FILTER DRYER VALVE CLEANING 46 FILTER DRYER CAKE REMOVAL 47 X-AXIS CENTRIFUGE CONTAINMENT

Containment of Basket Filtration Centrifuges ABSTRACT

VHP M100 BIODECONTAMINATION SYSTEM

SECTION LABORATORY EQUIPMENT CONSTRUCTION STANDARD PART 1: GENERAL Scope of Standard

XPert Balance and Bulk Powder Enclosures

Biological Safety Cabinets or Fume Hoods Which one to use?

Biological Safety Cabinets. Biological Safety Cabinets

Esco PCR Cabinet, Model PCR-4A_. Shown with optional support stand. Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR

MassBioLogics Welcomes. The New England Chapter Parenteral Drug Association. March 12, 2008

VHP ARD BIODECONTAMINATION SYSTEM

Innovation in air purification unmatched air quality

AIR SHOWERS CAP701 SERIES

Safe Operating Procedure (Revised 2/10)

VHP ARD Mobile Biodecontamination System

Animal Tissue Culture SQG 3242 Equipment and Lab design. Dr. SITI PAULIENA MOHD BOHARI

CLEAN AIR SYSTEM.

Pharmaceutical Facility Design

Biosafety Cabinets and Fume Hoods Supplemental Material (OHS_BIO304)

Ventilation for Healthcare Facilities

VWR symphony CO 2 INCUBATORS

BSC CLASS II, TYPE A2 BIOLOGICAL SAFETY CABINET SERIES. Optimum protection of personnel, product and environment. BSC Class

Howorth Air Technology. Pharmaceutical Containment Solutions

Ventilation for Healthcare Facilities. Topics to be Covered

Clarification Proposal Annex 1, PDA: A Global. Cleanroom and. Association. Clean Air Devices. Hasim Solmaz Lighthouse Worldwide Solutions

Standard Operating Procedure M.I.C.E.

Howorth Air Technology. Pharmaceutical Containment Solutions

Precision Containment for All Applications

ANIMAL RESEARCH PRODUCTS. Biological Safety Cabinets Animal Transfer Stations

General Purpose Laminar Flow Cabinets, Horizontal and Vertical. Horizontal Flow Vertical Flow

Faster UltraSafe Class II Microbiological Safety Cabinets. Protection, safety, reliability. And more.

GLOVEBOXES. Low-Cost Solutions for High Technology. Vol. 3, No. 18

Clean Air Laminar Flow Ceiling CG 3 A CLEAN AIR WORLD. Draft-free, comfortable room climate. Minimal, undisruptive noise level

SECTION BIOLOGICAL SAFETY CABINETS AND LAMINAR AIRFLOW WORK STATIONS

6/19/2015 BIOLOGICAL SAFETY CABINET. Types of Classes. Types of BSC.

Gloveboxes. Hoods & Vacuum Chambers Turnkey Systems

Soot Mitigation Strategies

Adv. 8.4 Guidelines for Biosafety Cabinets Rev

2010 International Conference on Biocontainment

VHP M100 Biodecontamination Systems

Gelaire BH-EN and UltraSafe cabinets

PhEn-602. Pharmaceutical Facility Design

Laboratory & Process Equipment

DRYAIR Turnkey Dry Room Standards

Faster BH-EN and BHG Class II Microbiological Safety Cabinets

Pharmacy Solution Set

Refrigerated Dryers. Cycling; Non-Cycling; High Pressure; High Temperature ,000 scfm

FLUID BED EQUIPMENT. Drying

LABGARD NU-602 CLASS II TYPE A2 ANIMAL HANDLING BIOLOGICAL SAFETY CABINET

BioSafety Cabinet- Class 100

Florida International University. Biosafety Cabinet Program

VHP M100 Biodecontamination Systems: Closed Loop

Environmental Health and Safety Biological Safety Program Guidance Document

Refrigerated Dryers. Cycling; Non-Cycling; High Pressure; High Temperature ,000 scfm

Safe Use of a Class II Biological Safety Cabinet

Microbiological Safety Cabinets

TOWER DRYERS TOTA TOT L VA AL V LUE. TOTA ALUE. TOT L SYSTEMS. AL SYSTEMS.

Washing Systems for Pails, Buckets and Jars

DOWNDRAFT BENCH SERIES

ORION. Safety Class 2 100% exhaust. ALMOST Rocket Science

PASSION THAT DRIVES PERFORMANCES. WASHINGSOLUTIONS

How to comply with CDC Guidelines

Lead-Lined Cabinetry. 7 Vreeland Road, Florham Park, NJ or

Automatic Cyanoacrylate Fuming Chamber 24 33T 60T 72XL. Safely Detect Quality Latent Prints and Reproducible Results

B. Design meeting requirements of the particular class and type of cabinet as follows:

Thermo Scientific 1300 Series A2

GLOVEBOXES. Low-Cost Solutions for High Technology. Vol. 3, No. 19

Down flow clean air cabinet Star of the Universe. Fortuna

GETINGE GEW 2100LS CAGE AND RACK WASHER PREVENTING CONTAMINATION IN ANIMAL CARE

L a b o r a t o r y E q u i p m e n t C a t a l o g

SMA Microbial Air Sampler System Product Guide

Sterilizer Model LS2020 Series Beta Star Life Science Products of R-V Industries

Bag Sealers Vacuum Sealers Vacuum Chambers Band Sealers Medical Packaging Flow Wrappers

Cold Energy Saver. Thermal Mass Cycling Refrigerated Air Dryers ( scfm)

Introducing The Reliance 200 and 250 Glassware Washing Systems.

Membrane Technologies DMD Series Dryers ESM Series Dryers

BLUE GALAXY DEPYROGENATION TUNNELS. Solid Dose Sol

Specifications. The Liquid Super Separator is a new concept of air filtration that is totally different from

STERITITE INSTRUCTIONS FOR USE

Micro 6. Main Features

COMPETITIVE INITIATIVE POWDER COATING SPRAY SYSTEM MINES TECHNICAL SPECIFICATION

Sentry Air Systems, Inc.

Clean Air Products 90-Degree Low Profile Left Hand ADA Compliant Air Shower Purchase Specification

TYPICAL CPA SPECIFICATIONS

Stability & Shelf Life

Fume Hood Safety TYPES OF FUME HOODS

SECTION AIR DUCT ACCESSORIES

CONSIDERATIONS ON FACILITY AND ENGINEERING CONTROLS IN THE WAKE OF USP <800>

Benchtop CO 2 Incubator. the Oasis 6400 series

ENVAIR lab CO2 Tri-Gas Incubator

Commissioning of a Mobile CL3 Laboratory: Lessons Learned

Transcription:

Isolators, RABs and Mobile Clean Rooms in Aseptic Processing Gary Partington Walker Barrier Systems gpartington@walkerbarrier.com

Isolators have been around the pharmaceutical industry since the early 1980s and in the nuclear industry (glovebox technology) since the 1950s. The intent of isolators is to create an airtight barrier or enclosure around a piece of equipment or process which provides absolute separation between the operator and product. The operator can perform tasks through half-suits or glove ports. Isolators provide a specific environment inside the isolator using HEPA filters. The environment can be positive pressure or negative, can have humidity control, oxygen control, use unidirectional airflow and can either protect the product from the operator as with aseptic processes or protect the operator from the product as with potent product handling. The earliest uses of aseptic isolators were for sterility testing. Sterility test isolators make up most of the aseptic isolators in use and are available in many different sizes and configurations.

Guidance for Industry Sterile Drug Products Produced by Aseptic Processing Current Good Manufacturing Practice Aseptic processing using isolation systems separates the external clean room environment from the aseptic processing line and minimizes its exposure to personnel. A well-designed positive pressure isolator, supported by adequate procedures for its maintenance, monitoring, and control, offers tangible advantages over traditional aseptic processing, including fewer opportunities for microbial contamination during processing. The guidance expands on such areas as: Materials of Construction Airflow/pressure differential/air classification Glove Integrity Transfer of Materials/supplies Decontamination Environmental Monitoring

Benefits of Isolator Technology for Aseptic Processing Ability to maintain sterility of equipment over a period of time Less expensive to operate versus clean room Virtually no sterility false positives No gowning required

Enclosures that are sealed to some standard of leak tightness, that contain within them a qualified controlled environment, at variance with the surrounding conditions. What is an Isolator

Isolator Design Considerations Types of Products to be Tested or Produced? Size of Isolator System? Ergonomic Mock Up? Materials of Construction? Method of Decontamination (Manual or Automatic)? Material Compatibility? Laminar or Turbulent Air Flow? Controls System? Transfer of Equipment and Material? Illumination of Enclosure?

Isolator Design Considerations Strategic Location of Gloves and Half-Suits Panel HEPA Filters for Aseptic Applications Shelving for Storage Oversize Blowers for rapid aeration Built-In Steritest System Rapid Transfer Ports (alpha-beta doors) Pass-Through Connections for Service Trash Receptacle and Evacuation of Filtrates Internal Fans for Sterilant Distribution Ports for Environmental Monitoring Mechanical Aids for Transferring Materials Glove Supports During Decontamination Autoclave, Oven and Freeze Dryer Interface Manual vs Automatic Valves PLC Control System Integration with VH2O2 Generators providing fully automatic decontamination cycles Pass-Through/ Ports for Services or Environmental Monitoring. Optional Yellow Lighting Built-In Steritest System

Design Considerations Design Tools 3D CAD Mock ups are an important part of isolator design. Construction is of wood and often uses actual components. Operators can perform ergonomic studies before final design. Mock Up Construction

Mock Up Construction It is important to involve the end user in the mock up evaluation

Isolator Raise/Lower Mechanically Adjusted Shelving and Hooks for Storage Operator Raise/Lower Hatchback Window

Materials of Construction 304 SS Flashing Polyurethane Casters Polyurethane enclosure 304 SS Shelf Advantages Lower Cost Easily Assembled/Disassembled Lightweight Good Visibility Good Flexibility for Glove Ports Disadvantages Difficult to Leak Test Subject to Punctures Canopies Need Replacing Limited Resistance to Chemicals Adsorption and Permeation of Hydrogen Peroxide 304 SS Frame

Materials of Construction Glove Ports - Ultem Gloves - Hypalon Gaskets FDA silicone 316L SS Shell Internal corner radius 5/8 Surface finish <22 Ra Laminated safety glass Polyurethane Casters 304 SS Frame High Resistance to Chemicals More Easily Leak Tested Durable No Adsorption/Permeation of Hydrogen Peroxide Better Aesthetic Appearance

Airflow: Product Protection / Airborne Capture Unidirectional / Turbulent HEPA Quality 99.997% Cleanliness Grade A - C Design Parameters Pressure: Typically +0.10 to +0.25 inches of water column Validated Decontamination of Internals: Requires good circulation to ensure even distribution of sanitant Concentration of VHP post Decontamination is typically <1ppm

Location Classified room not required. Limit access to non essential staff. Provide adequate space around isolators for maintenance, staging and moving of transfer isolators. Temperature and RH control of room is important, but no environmental monitoring of room is required. Uniform temperature conditions in room required so not to affect isolator sterilization methods.

Air Handling Systems HEPA filters are required. Meets Class 100 conditions at rest for sterility test and during operation for filling lines (UAF). Constant air over pressure required. Unidirectional (filling lines) or turbulent (sterility testing). The 2003 European Commission Guide to GMP (Revision to Annex 1) refers to laminar air flow (aka unidirectional) in isolators, but it deals with the manufacture of sterile medicinal products. There is no requirement for laminar air flow in a sterility test isolator. Turbulent airflow isolators have been used in sterility testing since the early 1980s and are still manufactured today. Typically no requirement for air velocity or air changes exist on sterility test isolators.

Air Handling Systems Sterility test isolators are closed systems. The 2004 Aseptic Processing Guide, still in use today says: Turbulent flow can be acceptable within closed isolators, which are normally compact in size and do not house processing lines. Other aseptic processing isolators employ unidirectional airflow that sweeps over and away from exposed sterile materials, avoiding any turbulence or stagnant airflow in the area of exposed sterilized materials, product, and container closures. In most sound designs, air showers over the critical area once and then is systematically exhausted from the enclosure. The air handling system should be capable of maintaining the requisite environmental conditions within the isolator.

Air Handling Systems- Positive Pressure Turbulent airflow HEPA filter Inlet and Outlet HEPA filters are provided at 99.97% efficiency for 0.3 micron particles Variable speed blower with pressure controller provides constant positive pressure

Gloves & Gloveports Ultem Molded Gloveports and retainers. Other materials include polypropylene and stainless steel Gloves made of Hypalon, Neoprene, or Butyl Gloves designed with a double o-ring groove to allow safe glove change-out Retainer secures glove in place, eliminating risk that glove will be pushed off the port during operation. Retainer also eliminates wrinkling of the sleeve inside the isolator resulting in a smooth surface for more effective cleaning.

Glove Testing Glove testing should be done on a routine basis. Test methods include: Visual inspection Ammonia testing with the isolator Pressure decay testing Available systems can be portable or integrated with the isolator. Measure one glove at a time or multiple gloves at a time.

Transfer Ports and Interface Interface Isolators Isolators Isolators are attached to exit door of pass-through sterilizers, depyrogenation ovens and lyophilizers to allow direct transfer of media, supplies, glassware, product etc. into the isolator system. RTP Systems RTPs allow 2 isolators to be connected and move supplies aseptically from one isolator to the other.

Rapid Transfer Ports (RTP) allow materials and product to be transferred from one isolator (or container) to another isolator without breaking integrity of the system. RTP Docking Sequence 1. RTP Alpha flange 2. RTP Beta Flange 3.Beta approaches Alpha 4. Beta sealed to Alpha 5. Double door opened 6. Transfer begins

Interface Isolators include: Autoclave Depyrogenation oven Lyophilizer Filling Machines Interface Isolators

Selector Switch (Low Level) Types of Controls PLC (Mid-Level) This level of control system is referred to as manual. A standard system would contain the following: A single loop Red Lion controller to control pressure Manual valves Switches for Phase selection An Allen-Bradley PICO controller (this is not a PLC) Pilot lights Audible alarm Some options: Type X purge system for classified environments This system is typically used for the low cost isolator or a simple standard isolator. It can also be easily integrated into a Class I, Division I environment. This has limited capabilities and options. This level of control system is most common, having many features and greater flexibility for future capabilities. A standard system contains the following: 6 color, PanelView+ 600 or 1000 touchscreen Allen-Bradley Micrologix or CompacLogix PLC Pneumatic valves An emergency stop button Automatic control of all features PID loop tuning Some options: Type X purge system for classified environments Humidity control Oxygen control Ammonia leak test pressure control This system is the most commonly used and will fit most customer needs.

Aseptic Isolators Sterility Testing The use of barrier isolator technology for sterility testing of pharmaceuticals and medical devices has clearly demonstrated the ability to significantly decrease and even eliminate the incidence of false positive results. The superior testing results have not only increased laboratory testing confidence but have also decreased overall operation costs.

Glove Sterility Testing Isolator Glove Sterility Test Isolator Available in 3, 4 and 6 glove sizes Stainless steel and glass construction with oversize blower and valves allow for rapid decontamination. Ability to decontaminate and test in the same day. No RTP required. No validation of sterility" maintenance required. Optional airlock

Large Sterility Test Isolator Systems Sterility Test System with Transfer Isolator and Work Station Isolator. Features Include: 350mm RTP System Optional PLC with Automatic Valves Large, Locking Casters Positive Pressure Ventilation/Filtration System Distribution Fans 316L Stainless Steel & Glass Construction

Decontamination (H2O2) Isolator PLC system communicates directly with portable hydrogen peroxide generator. Automatic valves require no operator intervention. System can be automatically decontaminated overnight. Isolator PLC system communicates directly with integrated hydrogen peroxide generator. Cycle enhancements may include catalytic converters and heat.

Decontamination (other agents) Chlorine Dioxide is widely used in decontaminating in the animal research enclosures. Nitrogen Dioxide is being tested for use in the pharmaceutical industry o NO 2 has a much lower oxidation potential (-0.8 V) than other sterilants (not principle mechanism of microbial inactivation) o o o o o Stable in the vapor form Initial studies show faster cycle times than other agents Low temperature and pressure requirements Material compatibility should be verified Residuals easily removed via aeration (minimal absorption)

Fill Machine Isolators Syringe Fill Machine Isolator Vial Fill Machine Isolator & Integrated Lyophilizer

Aseptic/Containment Filling System RadioPharmaceutical Liquid Filling Interface Isolator Integrated Base on Filler 350mm RTP for Component Entry Manipulators Unidirectional Ventilation/Filtration System 1.25 thick 316L Stainless Steel & Lead Glass Construction Customer Nuclear Exhaust

Other Aseptic Isolator Uses Unidirectional Lyophilizer Interface Isolator. Includes pop-up half-suit, Oxygen Control and RTP system Horizontal Unidirectional Flow Combo Isolator. Used for drum lid removal, cone placement and drum separation Formulation and Sampling Isolator Horizontal Unidirectional Flow Powder Addition Isolator

Environmental Monitoring Non Viable Monitor Viable Monitor Viable and non-viable particle monitoring can be conducted inside an isolator Both are required in a filling machine isolator Particle monitoring is not required in a sterility test isolator but is gaining popularity

Restricted Access Barrier RABs Restricted Access Barrier (RABs) were developed to enhance aseptic process carried out in conventional clean rooms. As defined by the ISPE in 2005, a RAB system is to include: Rigid wall enclosure ISO 5 UAF environment Gloves for set up and interventions Automation of the process wherever possible High level disinfection Rare open door interventions RABs qualification will be similar to a clean room and includes: Air exchange rates Airflow velocity Pressure differential Smoke tests Environmental monitoring

Open RABs Restricted Access Barriers (RABs) Open Passive RABs utilize existing clean room overhead air supply systems to deliver HEPA filtered air over a critical process before returning air back into the clean room without the need for additional fans or filters. The RABs enclosure is not sealed to the filling machine. Open Active RABS have an onboard fan/filtration units to supply HEPA Filtered air over a critical process before returning air back into the clean room. The RABs enclosure is not sealed to the filling machine. Diagrams from BioQuell

Restricted Access Barrier (RABs) Closed RABs Closed RABs is a positive pressure system with an onboard fan/filtration units to supply HEPA Filtered air over a critical process which then passes through exhaust filters before being recirculated. Airflow recirculates with the RABs enclosure. RABs typically are not decontaminated, unless the filling machine and all other openings can be sealed. All RABs can include glove ports, RTP systems, access doors with interlocks and EM systems as required.

Restricted Access Barriers (RABs) For existing equipment, a site visit is typically required to measure the equipment and develop a 3D model of the RABs and equipment to be enclosed. Mock ups can be built from plastic components for review on site.

Restricted Access Barriers (RABs) RABs delivery and set up Installed Open-Passive RABs

Restricted Access Barriers (RABs) Passive, open RABs installed over a filling machine. RABs utilizes clean room ventilation filtrations system and are mounted to the facility floor. Access doors are provided with no glove ports. Any door opening/operator intervention inside the RABs should be documented.

Mobile Clean Room (MCR) The Mobile Clean Room Why Go Mobile? HVAC and MCR Features Construction Extended Width Transportation and Positioning Requirements

Clean, flexible manufacturing space Pre-engineered and ready-to-use Constructed and shipped to your facility Key Applications: Manufacturing R&D Processing Dimensions Square Feet: 440 Overall: 48 L x 18 W x 12 H Main Room: 25 x 17-7 Weight: ~35,000 lb. Mobile Clean Room (MCR)

Significantly reduce construction costs Considered equipment so write off faster Reduce operating costs by 20% Rapid deployment Install process equipment at one location, then move the MCR with the process closer to your market Intellectual property containment Flexible Mobile Clean Room (MCR)

ISO 7 MCR with redundant systems* (Redundant HVAC system includes fans, cooling coils, HEPA filters, T & RH sensors) *Note: All savings are approximate, compared to stick-built clean rooms

MCR HVAC ISO Class 5, 6, 7 or ISO Class 8 Clean Air Zoned pressure control between rooms BSL1 positive pressure or BSL2+ and BSL3 negative pressure operation 20-40 Air Changes per Hour Temperature control from 64-75 0 F Relative humidity reduction to 45-50% Ceiling HEPA s Mechanical Room

Bidirectional or unidirectional personnel flow Entry personnel airlock Mechanical equipment airlock with 6-foot wide doors Exit personnel airlock Positive or negative sink operation Cascading pressure operation between rooms Cooling and RH reduction by chilled water (electric chilled water options available) Electric or hot water air re-heat Clean room doors with windows, door closers, interlocks, adjustable sweeps FM-200 fire suppression system to NFPA 70 code Clean room fluorescent T5HO (upgrade to LED available) Sealed construction for VHP decontamination Side windows MCR Design Considerations

Epoxy coated interior walls and floors with radius corners Epoxy coatings are field repairable if need arises BI/BO recirculating redundant supply HEPA filters Redundant supply fans Room supply HEPAs with room side or roof side changeable BI/BO redundant exhaust filters and exhaust fans Condensate pump RH/temperature reduction by chilled water Hot water or electric reheat air PLC controlled with Ethernet Easy maintenance access Utility panel for additional service entry Rigid aluminum construction Floor loading of 500 lb./square foot Floor hard points available for heavy process equipment such as centrifuges MCR Design Considerations Epoxy Coved Flooring

Mobile Clean Room (MCR) Extended Width Doubles the manufacturing space. Built and shipped in two halves.

Joined together in customer facility.

MCR Uses ISO 8 manufacturing space with ISO 5 isolators

Example of ISO 8 extended width MCR might include: Vial washer/dry heat tunnel 100VPM vial fill machine Autoloader Capper External Vial Washer Isolators for fill machine, autoloader & capper VHP generator

New facility ready for MCRs

MCR Facility Requirements: Indoor facility ISO 8 hallway to connect to MCR Inlet air: conditioned room air 500-1500 CFM Inlet air: 52 F dew point Exhaust air duct Chilled water: 40 F at 15 GPM Hot Water reheat: 150 F at 10 GPM Electric options available for hot/chilled water Compressed air 60-80 PSIG, 10 CFM Electric Power 208 VAC 3 Phase, 200 Amps Condensate drain

Thank You