Advanced Fire Alarm Systems Training Program Outline (5 Day)

Similar documents
Minimum Standards for Engineers Practicing Fire Protection Engineering in the State of Oklahoma September 14, 2016

1. Floor above/floor below notification. 2. Private alarm notification. 3. Not Used 4. Voice alarm notification. 5. Not Used.

Fire Alarm System Fundamentals

NFPA 72 Code Changes vs 2013

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course

NFPA Siemens Industry, Inc. All rights reserved. usa.siemens.com/infrastructure-cities

AGENDA NFPA TECHNICAL COMMITTEE ON NOTIFICATION APPLIANCES. Report on Comments Meeting, October 13-14, Richmond Marriott, Richmond, VA

Unified Fire Authority - Fire Prevention Bureau

Florida Building Code 2010

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

Significant Changes to the 2012 IFC Semiconductor Fabrication Facilities. Scott Stookey Senior Technical Staff International Code Council, Austin TX

1.3 REFERENCE STANDARDS

PART 1 GENERAL Quality Assurance A. Fire Alarm Contractor Qualifications:

CAN/ULC-S1001, INTEGRATED SYSTEMS TESTING OF FIRE PROTECTION & LIFE SAFETY SYSTEMS Simon Crosby, LEL, CET, CFPS October 21, 2015

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST FIRE ALARM SYSTEM INSTALLATION

CAN/ULC S Integrated Systems Testing of Fire Protection and Life Safety Systems and Fire Protection Commissioning

CHAPTER 61G15-32 RESPONSIBILITY RULES OF PROFESSIONAL ENGINEERS CONCERNING THE DESIGN OF FIRE PROTECTION SYSTEMS

Maintaining Building and Fire Safety During Active Assailant Events and Other Terrorist Events

CAN/ULC-S INTEGRATED SYSTEMS TESTING OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS

Automatic Fire Alarm Association Webinar On Inspection, Testing, And Maintenance Of Fire Alarm Systems

Liberty Township Fire Department Fire Prevention Bureau. Clean Agent Fire Protection Plan Submittal Checklist

1 Exam Prep Fire Alarm Signaling Systems Tabs and Highlights

Fire Alarm System Inspection and Testing Report

PART 1 GENERAL Quality Assurance A. Fire Alarm Contractor Qualifications:

MNEC NFPA 72 WHITE PAPER

Questions/Comments for Richard Roux from Webinar on 7/11/13

SECTION : FIRE ALARM & DETECTION SYSTEMS

CAN/ULC-S1001, INTEGRATED SYSTEMS TEST OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS

The 2013 National Fire Alarm and Signaling Code

Bold items are particular to the City of Euless

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Brighton Area Fire Authority

BUILDING CODE INTERPRETATION

2. HVAC and smoke control systems; fire, smoke, and combination fire/smoke dampers. 5. Central control and monitoring system.

COUNTY OF KINGS KINGS COUNTY JAIL EXPANSION PHASE III

FIRE ALARM SYSTEMS & 780 CMR. Dave LeBlanc, PE, FSFPE March 17, 2015

First Revision No. 158-NFPA [ Global Input ] Submitter Information Verification. Committee Statement


Smoke Detector Activation of any smoke detector shall start the alarm verification mode.

STATE FIRE MARSHAL S REQUIRED FIRE PROTECTION SYSTEMS NARRATIVE REPORT

MODULE 8. Tying the Systems Together: Emergency Control Functions and Interfaces

Standard of Practice - Fire Alarm Systems. NOTE: Significant revisions or additions to the previous standards are highlighted in italics.

SPECIFICATION: AlarmLine TM INTELLIGENT LINEAR HEAT DETECTION

2018 NICET Code Transition Changes

NFPA Changes

Innovative protection that combines power and flexibility

Principal s Guide for Fire Safety Planning in Schools. To be kept in School Administration Office

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 5, 2018

University Design Standard Fire Alarm Systems

Table OUT OF SERVICE. Building Fire Video 1/15/ Inspection, testing and maintenance. Standards Further Referenced by FCNYS

I. Scope: II. Environmental Health and Safety Fire Alarm System Impairment Program - Guideline Revision Date: April, 2018

M E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot

Agency for Health Care Administration

Fire Alarm Wiring. Circuit types, styles and limitations

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

SECTION 907 FIRE ALARM AND DETECTION SYSTEMS

Releasing Systems. Rob Mennie Senior Consultant Gage-Babcock & Associates Ltd.

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)

ONYX FirstVision Specification Interactive Firefighters Display

SECTION FIRE ALARM STANDARDS REVISED CONSTRUCTION STANDARD

Risk Management Services

Recommended Amendments to the 2015 International Existing Building Code North Central Texas Council of Governments Region

M E M O R A N D U M. NFPA Technical Committee on Building Services and Fire Protection Equipment

Fire Protection System and Life Safety Evaluation of Building X. Anthony W. Sublett

APPENDIX H (DESIGN SUBMISSION CRITERIA)

Valuation: # of Plans Submitted: # of pages: Type of Work (select one): New Addition Existing System/Modification Project Name: Scope of Work:

Fire Sprinkler Plan Submittal Form

Fire Alarm System Training

The Technical Committee on Commissioning and Integrated Testing

Fire Alarm Acceptance Testing & On-Going Maintenance with The Joint Comm. Standards / Reporting. Prepared Especially for : OSFM TEC 2016

Martin Huber 26September 2017 F&G SOLUTIONS FOR THE PROCESS INDUSTRY

2019 COURSE CATALOG (rev )

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

Revised March 2015 Fire Alarm Systems Verification. Schedule I(A) Services. *Manditory Site visit required*

Oklahoma. 265: Incorporated national codes and standards The following national codes and standards are incorporated by reference:

Full Service Central Station Fire Alarm Listing Evaluation

Narrative Reports As Regulated by 780 CMR, Section 903.0

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

TRAINED CROWD MANAGER VENUE SPECIFIC TRAINING CURRICULUM OUTLINE

Fort Rouge Leisure Centre Section HVAC Upgrades Phase 2 Page 1 of 5 Bid Opportunity No March 2013 FIRE ALARM SYSTEMS

Prefunctional Checklist

SPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE SHP PRO CONTROL PANEL SYSTEM

ICC Annual Conference October 2016

Agency for Health Care Administration

EC 5.10 FIRE PREVENTION MANAGEMENT

MAINTENANCE OF FIRE PROTECTION DEVICES WITHIN RESIDENTIAL SUITES OF MULTI-FAMILY BUILDINGS

FIRE INSPECTORS GUIDELINES FOR PLAN REVIEWS AND INSPECTIONS OF NEW CONSTRUCTION / ADDITIONS AND CHANGE OF OCCUPANCY

H BUTCH BROWNING FIRE MARSHAL BUILDING REHABILITATION

NFPA Changes

2012 OBC Changes. Summary of key changes to Life Safety and Fire Protection Systems for CFAA January 22, 2014

MANUAL OF DESIGN CRITERIA AND SPECIFICATIONS FOR FIRE DETECTION AND ALARM SYSTEMS PUBLIC SCHOOLS IN NEW MEXICO

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

El Reno Fire Department Fire Alarm Plan Review Worksheet

MULTI-PHASED FIRE ALARM AND MASS NOTIFICATION SYSTEM UPGRADES: The Authority Having Jurisdiction (AHJ) and Proper Planning

Fire alarm system specification for multiple tenant retail buildings

Fire Prevention Coffee Break Training. February 2017

Transcription:

Advanced Fire Alarm Systems Training Program Outline (5 Day) Day 1 Prescriptive and Performance-Based Design Understand the methodology in accessing the threat of fire within a structure. Know the difference and application between prescriptive and performance based design. Topics include hazard analysis, fire signatures and heat growth rates. Building Codes and Standards Understand building codes and how they determine building classification which governs type of system installed. Review building codes to determine special requirements for fire alarm systems. Know the difference between codes and standards and when and how they are applied. Insurance Agencies and Organizations Become familiar with the role of insurance agencies and organizations and how they influence fire alarm design and installations. Know the requirements for acceptance and system approval, and the protocols of each agency. Occupancy Classifications Understand the codes that govern the occupancy classifications of buildings and structures. Know the fire protection standards of various occupancy classifications and the requirements. Be familiar with documentation requirements for fire protection and detection systems. Project Specifications Project specifications consist of the body of information that should guide designers, installers, and Authority Having Jurisdiction (AHJ) through all phases of the project. Understand the purpose, definitions, and types of specifications. Day 2 Combustion - Theory and Principles Develop and understanding of the chemical reaction in the combustion process and the signature produced. Understand the stages of material heating and thermal particulates. Know advantages of various methods of detection.

Smoke Propagation Principles in Buildings Develop an understanding of the properties and characteristics of smoke movement. Know the effects of pressure, temperature and partitions affecting the expansion of heated gases produced by combustion. Prevention of Nuisance and False Alarms Know the proper selection and placement of automatic detectors and maintenance programs for reliable and proper operation of fire alarm systems. Understand system program features to reduce unwanted alarms from utilizing alarm verification, positive alarm sequencing, cross zoning and presignal. Also electronic and pneumatic retard mechanisms for sprinkler water devices. Hazard Protection Analysis Understand the methods used to determine the risk for a particular facility. Know the factors that influence a design and inputs from insurance agencies, stakeholders and authority having jurisdiction. Determine suitable detection methods and technologies to satisfy performance requirements. Hostile Environment Design Considerations Discuss various environmental hazards and conditions associated with fire alarm system installation. Know the proper device selection or installation method to reduce or prevent damage. Be able to apply codes determined by environment. Day 3 Reliable and Survivable Systems Types of design and installation methods to allow for continuous operation of systems. Location and protection of equipment and wiring depending on environment. Understand equipment listing, system reliability, system survivability, installation methods and environmental considerations. Detector Spacing Review the various smoke detection principles and the advantages of their application. Know the code requirements for location and spacing of smoke detection. Be able to lay out detectors within a given space. Know the code requirements for location and spacing of thermal detection. Understand how elevations affect response and detection principles. Be able to lay out thermal detectors within a given space. Systems for Smoke Control Know the requirements, purpose and methods of smoke control in buildings. Discussing placement of detectors and building functions controlled by the fire alarm system. Understand smoke movements and how it is purge or contain for occupant relocation and egress. Sprinkler System Interface Understand the operation and interconnection to a fire alarm system of various sprinkler wet and dry pipe alarm devices such as water flow, pressure, temperature, and level, retarding devices, gate valve supervisory switches, and fire pumps.

Ancillary Systems Understand the function of ancillary systems permitted by the code, such as fan shutdown, elevator capture, and smoke management systems. Know their purpose, location, operation, restrictions, circuit and supervision requirements. Special Hazard Protection Systems Be able to lay out a fire detection system for protection of special hazards. Facilities discussed shall include data centers, telecom and server rooms, document storage and critical processes. Know the proper location and spacing of smoke detectors, manual release and abort stations. Understand the interconnection to the building fire alarm system and HVAC equipment interface of. Interconnection of Systems Discuss the interconnection of systems associated with fire alarm functions. Know the purpose, operation and connection requirements. Covers extinguishing systems, to include sprinkler, clean agent, co2, dry/wet chemical and foam. Also detector selection and system configurations Day 4 Voice Systems Understand how factors that affect intelligibility determine the selection and placement of speakers. Know the operation of big audio and arrays for outdoor applications and proper tapping of speakers for indoor operation. Basic understanding of Mass Notification Systems (MNS) and Emergency Communication Systems (ECS). Intelligibility Standards Know the approved methods to demonstrate adequate intelligibility of voice systems. Understand the factors that affect intelligibility and acoustically designated spaces. Understand intelligibility methods (CIS, STI), materials and acoustic properties and acoustically designated spaces (ADS). Surge and Transient Protection Understand the principles of induction and sources of disruptive energy on fire alarm systems. Know the types and methods of protection to minimize those effects. Be able to apply type of suppression methods for the anticipated hazard. Electricity and Electronics Understand the difference between DC and AC circuits, and know the characteristics of each. Be able to identify series and parallel circuits, as well as calculate current, voltage and resistance. Become familiar with electronic components and their usage. NFPA 70 Understand how the National Electric Code (NEC) governs the installation methods and materials required for fire alarm systems. Know how to use box and conduit fill, conductor characteristics and other tables.

Tactile Notification Understand the operation, selection, location, spacing, mounting, and use of tactile and alternate visible alarm notification appliances. Topics include digital signage, LED, text messaging and distributed recipients Shop and Riser Drawings Know the requirements that govern the need for shop drawings and what is included. Understand the purpose of plans, wiring diagrams, riser diagram and matrix, to include sequence of operation. Become familiar with information required to show the number and size of conductors, tagging conventions, conduit and the location of each system component. Day 5 Project Management Be familiar with project timelines and the installation of fire alarm and protection systems. Demonstrate ability to communicate with agencies and coordination of general trades to meet project deadlines. Know the methods of tracking progress and characteristics of each. Contract Documents Understand the various agencies that govern the content of contract documents and when they are used. Be familiar with terms and purpose of site programs. Know procedures for contract administration and coordination of communication during a project. Construction Plans and Drawings Acquire a working knowledge of various types of plans used in the construction industry. Use standard plans to determine dimensions, types of materials, elevations, locations, and other information needed for a building fire alarm system. Be able to generate a bill of material listing symbol, description, manufacturer and part number of all equipment used. Project Correspondence Utilize common rules of grammar and punctuation to form clear sentences and paragraphs in composing project documents. Adhere to industry accepted guidelines for routing and distribution. Be familiar with common forms and methods of communication in the construction industry. Know the purpose and application of standard documents submitted. Proposal Generation Determine the proper selection of systems and components to satisfy customer specifications. Understand how local, state and agency requirements affect the selection and design of fire alarm systems. Project Close-Out Know the various documentation that is required to for project close out. Understand the proper distribution of materials and archive procedures of documents. Understand the Record of Completion, test reports, and as-builts.

Course Evaluation An Exam will be administered at the conclusion of the course. Students will be limited to one-hour and the exam will consist of 60 questions. References allowed during exam will be NFPA 72, the National Fire Alarm Code (2007), NFPA 70, the National Electric Code (2008), NFPA, 101 the Life Safety Code (2006) and the International Building Code (IBC) (2006). Sincerely, Paul J. Inferrera, SET