HIPPS High Integrity Pressure Protection System

Similar documents
HIPPS High Integrity Pressure Protection System

Addressing Challenges in HIPPS Design and Implementation

High Integrity Pressure Protection System

Safety Instrumented Systems

IEC61511 Standard Overview

SIL Safety Guide Series MS Single-Acting Spring-Return Hydraulic Linear Actuators

Digital EPIC 2 Safety manual

FUNCTIONAL SAFETY IN FIRE PROTECTION SYSTEM E-BOOK

Practical Methods for Process Safety Management

InstrumentationTools.com

Safety in the process industry

The SIL Concept in the process industry International standards IEC 61508/ 61511

FUNCTIONAL SAFETY: A PRACTICAL APPROACH FOR END-USERS AND SYSTEM INTEGRATORS

Fire and Gas Detection and Mitigation Systems

Safety Transmitter / Logic Solver Hybrids. Standards Certification Education & Training Publishing Conferences & Exhibits

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

Presenter Joe Pittman

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

Functional Safety Solutions

Tank protection example using Simatic

Safety Instrumented Systems Overview and Awareness. Workbook and Study Guide

100 & 120 Series Pressure and Temperature Switches Safety Manual

Numerical Standards Listing

Process Safety - Market Requirements. V.P.Raman Mott MacDonald Pvt. Ltd.

, CFSE, Senior Manager, ABB Taiwan;, 2011/9/2. Functional Safety. ABB Group September 5, 2011 Slide 1

Failure Modes, Effects and Diagnostic Analysis

Functional Safety: the Next Edition of IEC 61511

United Electric Controls One Series Safety Transmitter Safety Manual

Overfill Prevention Control Unit with Ground Verification & Vehicle Identification Options. TÜVRheinland

Measurement of Safety Integrity of E/E/PES according to IEC61508

Why AC800M High Integrity is used in Burner Management System Applications?

Numerical Standards Listing

Reliability of Safety-Critical Systems Chapter 1. Introduction

Session Four Functional safety: the next edition of IEC Mirek Generowicz Engineering Manager, I&E Systems Pty Ltd

ADIPEC 2013 Technical Conference Manuscript

Safety Instrumented Systems The Smart Approach

Failure Modes, Effects and Diagnostic Analysis. Rosemount Inc. Chanhassen, Minnesota USA

SAFETY MANUAL. Intelligent Sensors for H 2 S Gas Applications

Functional Safety Manual June pointek CLS500/LC500

Options for Developing a Compliant PLC-based BMS

Emerson Automation Solutions Products & Services

Proof Testing Level Instruments

Integrated but separate

Safety Integrity Verification and Validation of a High Integrity Pressure Protection System to IEC 61511

Functional Safety Manual Oil Leak Detector NAR300 System

ULT NE WORKSHOP ON THE PREVENTION OF WATER POLLUTION DUE TO PIPELINE ACCIDENTS

Deluge Valves. Model 68 DE\ EL. Electrically Actuated Remote-Reset Deluge Valve. Dorot Fire Protection Division. Certification & compliance by design

SAFETY MANAGER SC Ensure safety, simplify operations and reduce lifecycle costs

Guidelines. Safety Integrity Level - SIL - Valves and valve actuators. February Valves

INTERNATIONAL STANDARD

ACCURATE FAILURE METRICS FOR MECHANICAL INSTRUMENTS IN SAFETY APPLICATIONS

Failure Modes, Effects and Diagnostic Analysis. PR electronics A/S Rønde Denmark

Failure Modes, Effects and Diagnostic Analysis

User s Manual. YTA110, YTA310, YTA320, and YTA710 Temperature Transmitters. Manual Change No

The evolution of level switches and detectors

Technical Paper. Functional Safety Update IEC Edition 2 Standards Update

Is your current safety system compliant to today's safety standard?

FUNCTIONAL SAFETY MANUAL

Flow Control. ... The Heating, Ventilation and Air Conditioning Industry. Fan N.C. Boiler

FUNCTIONAL SAFETY OF ELECTRICAL INSTALLATIONS IN INDUSTRIAL PLANTS BY OTTO WALCH

Australian Standard. Functional safety Safety instrumented systems for the process industry sector

C. B. Trading Corporation

Failure Modes, Effects and Diagnostic Analysis

Custom Engineered Design. English

BRIDGING THE SAFE AUTOMATION GAP PART 1

Failure Rate Data, Safety System Modeling Concepts, and Fire & Gas Systems Moderator: Lori Dearman, Webinar Producer Thursday, May 16th, 2013

INTERNATIONAL STANDARD

2015 Functional Safety Training & Workshops

Applying Layer of Protection Analysis (LOPA) to Accelerator Safety Systems Design. Feng Tao

ue short form catalog Leaders in Safety, Alarm & emergency Shutdown

Aeon International Ltd Blenheim House, Falcon Court Preston Farm Industrial Estate Stockton on Tees TS18 3TS, United Kingdom

Tasmanian supplier of high quality instrumentation, control and electrical equipment for all industries. Mining, Food and Beverage, Water and

White Paper. Integrated Safety for a Single BMS Evaluation Based on Siemens Simatic PCS7 System

Ronald Sigmond 26 Oct 2016 FLAME MONITORING, GAS HANDLING SYSTEMS AND BURNERS

Simply reliable: Process safety from Endress+Hauser

Our Portfolio. Valve Automation Centre 18 Airpark Place Guelph, ON N1L 1B2 Canada Phone: +1 (519)

Pekos Valves stocks on line

Process Safety. Allan Rentcome Director Engineering Process Safety Technologies. Insert Photo Here

WATER-TUBE POOL HEATERS

APPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview


SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY

IEC PRODUCT APPROVALS VEERING OFF COURSE

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis

SAFETY RELAY APPLICATION

We Manufacture Critical Service Valves For The Worlds Industries

Our Portfolio WINNER

The agri-motive safety performance integrity level Or how do you call it?

Beyond Compliance Auditing: Drill til you find the pain points and release the pressure!

WATER-TUBE POOL HEATERS

Assessment of the Safety Integrity of Electrical Protection Systems in the Petrochemical Industry

USER APPROVAL OF SAFETY INSTRUMENTED SYSTEM DEVICES

THE ULTIMATE SOLUTION FOR GAS DETECTION SYSTEMS. DRÄGER REGARD

Numerical Standards Listing

GAS MONETIZATION PIPELINES

NEOTeCHA Reactor Sampling Type PV

NFPA 85 COMPLIANCES OF BMS: A CASE STUDY OF BOILER CONTROL AT SBM OFFSHORE MALAYSIA COMPANY 1. AHMED ABOUELRISH 2 Universiti Teknologi Petronas

USER S INFORMATION MANUAL

PRIMATECH WHITE PAPER CHANGES IN THE SECOND EDITION OF IEC 61511: A PROCESS SAFETY PERSPECTIVE

Transcription:

HIPPS High Integrity Pressure Protection System

L&T Valves L&T Valves Limited (Formerly Audco India Limited) is a wholly owned subsidiary of Larsen & Toubro. Backed by a fifty-year track-record of excellence and world-leading innovation, the company provides engineered flow-control solutions for key sectors of the economy such as oil & gas, power, petrochemicals, chemicals, fertilizers and pharmaceuticals. Product Range: Gate, Globe & Check Valves Valves for Power Pipeline & Process Ball Valves Triple-offset Butterfly Valves Flanged & Wafer-type Butterfly Valves Double Block and Bleed Plug Valves Control Valves Customised Solutions Designs for the valves are created by an experienced team of valve experts who have a deep understanding of user-industry processes. An extensive manufacturing and quality assurance infrastructure ensure that world-class designs are transformed into high performance products. Every phase of manufacture is governed by an institutionalised environment, health and safety policy. L&T Valves marketing network spans the globe reinforced by strategic alliance with key international distributors. In India, it has a presence in every industrial centre through a network of offices, field engineers, distributors, automation centres and service franchisees. 2

High Integrity Pressure Protection System L&T Valves offers a range of customised capable High Integrity Pressure Protection Systems (HIPPS) for over-pressure protection leveraging our expertise of five decades in flow-control and system integration. High Integrity Pressure Protection System (HIPPS) is a Safety Instrumented System (SIS), which by definition, is a distinct, reliable system used to safeguard a process to prevent a catastrophic release of toxic, flammable, or explosive chemicals. In industrial plants, flare systems are primarily used for burning off flammable gases released by pressure relief valves during unplanned over-pressurization of plant equipment. Flaring and venting constitute a significant source of greenhouse gas (GHG) emissions, and the elimination of GHG emissions from flaring in the world would account for at least 10% of total emissions reductions as per the Kyoto protocol. HIPPS can be employed to prevent over-pressurization of a plant by shutting-off the source of the high pressure gas rather than by releasing it to the atmosphere. This system closes the source of over-pressure within two seconds and has at least the same reliability as a safety relief valve or flare system. As per ASME Section VIII, UG-140, which covers Over-pressure Protection by System Design, HIPPS can be used for the following applications: Chemical reactions so fast the pressure propagation rate could result in loss of containment prior to the relief device opening Chemical reactions so fast the lowest possible relieving rate yields impractically large vent areas Exothermic reactions occurring at uncontrollable rates Plugging, polymerization, or deposition formed during normal operation Reactive process chemicals relieved into lateral headers with polymerization and thus plugging, rendering the relief device useless; Multi-phase venting, where actual vent rate is difficult to predict Reducing GHG through regulations such as Kyoto protocol 3

Community Emergency Response Plant Emergency Response Mitigation Relief Valve/ Rupture Disk Prevention Safety Instrumented System (HIPPS) Codes & Standards API 521 and ASME code case 2211 spell out the conditions when a SIS can be used as an alternative to a pressure relief device. HIPPS must provide an installation that is as safe as or safer than the pressure relief device that it replaces. Control and Monitoring Process In addition, the SIS design must comply with international standards IEC 61511 and IEC 61508. IEC 61508 is a standard for functional safety of electrical, electronic and programmable electronic equipment and included mechanical components that are necessary to execute the safety function. IEC 61511 was developed for integrators, SIS designers and users as it deals with process sector implementation of the IEC 61508 standard. IEC 61511 has been adopted in the US as ANSI/ ISA S84.00.01. Implementing HIPPS as an SIS would result in risk reduction of the plant facility by prevention method rather than mitigation. The recommended safety integrity levels for HIPPS would be either or SIL-4. The Risk reduction factor RRF and Average probability of failure on demand (PFD avg. ) listed in IEC 61508 are: Safety Integrity Level Risk Reduction Factor (RRF) PFD (Avg. Probability of Dangerous Failure on Low Demand Mode) PFH (Avg. Frequency of Dangerous Failure on High Demand Mode) SIL-4 100,000 to 10,000 10-5 to <10-4 10-9 to <10-8 10,000 to 1000 10-4 to <10-3 10-8 to <10-7 SIL-2 1000 to 100 10-3 to <10-2 10-7 to <10-6 100 to 10 10-2 to <10-1 10-6 to <10-5 IEC 61508 lists possible methods to determine applicable Safety Integrity Levels, such as Risk Graph Method given below. Starting point for risk reduction elimination Consequence Slight Injury No influence to the environment Death to 1 person Periodic influence to the environment Frequency & exposure time Rare Frequent Possibility of avoiding hazardous events Possible Almost impossible Possible Almost impossible Probability of unwanted occurrence Relatively High a SIL1 SIL-2 Low -- a SIL-2 Very Low -- -- a Death to several people Permanent influence to the environment Many People Killed Rare Frequent SIL-4 h SIL-4 SIL-2 a: No special safety requirements h: An E/PE safety related system is not sufficient Source - IEC 61508-5, Figure E.2 & DIN 19250 4

Components of a HIPPS system M A PST M A PST A typical HIPPS system comprises the following: Three pressure sensors (2oo3 voting) that detect the over pressure in the line A logic solver which receives and processes the input signal from the sensors and transmits the output to the Solenoid Valve in the final element. A final element (Actuated Valve) which perform the emergency closure action via a Solenoid Operated Valve (SOV) to bring the process to a safe state. Typically, 3 SOVs are used - a manual-reset SOV (M), an auto-reset SOV (A) and one for Partial Stroke Testing (PST). The above schematic is a typical HIPPS architecture and the components in the loop can vary according to customer specification and requirement. L&T Valves can offer you a Ready to Fit skid designed for customer requirements. Pressure Transmitters The pressure transmitters detect the high pressure in the system and the safety loop may include a minimum of three transmitters, which operate in a 2oo3 voting logic, to achieve the requirement. Thus failure of one transmitter channel to respond will not affect safety integrity. If a fault develops on one transmitter channel this would be revealed by an alarm and can be intervened without causing HIPPS activation. Transmitters used in a voting arrangement are diverse, that is, of different manufacturers or technologies, to reduce the likelihood of common mode failures. Common pressure transmitters used employ capacitance, piezo-resistive or Silicon resonant technology. Based on the requirement, the three pressure transmitters can either be directly connected to the main line with double block and bleed valve arrangement or alternatively a High Integrity Manifold Block (HIMB) shall be used to connect Gauge Pressure Transmitters with process. When provided, HIMB shall have integrated block and bleed facility for three transmitters & shall be mechanically interlocked with tamper-proof facility in such a way that only one pressure transmitter can be isolated or vented at any one time. Logic Solver The Logic Solver processes signals from the sensors and closes the final element by de-energising the SOV. The logic solver hardware must be designed to meet the performance requirements, as a minimum, in accordance with IEC 61508. The logic solver can be either solid state, or programmable electronic systems (PE). Programmable electronic systems are provided with additional self-diagnostics and fault tolerance. Control systems from L&T Electrical and Automation 5

Final Element Final elements (Actuated Valves) are accorded the highest priority in a HIPPS loop as studies suggest that they account for 50% of safety loop failures historically and calculations suggest that their contribution to PFD avg. is the highest when compared with the sensors and logic solver. Thus selection and design of valves and actuator is of paramount importance in a safety loop. Safety loop failures Final Elements 50% Sensors 42% Logic Solver 8% Contribution to PFD avg. Final Elements 49% Sensors 26% Logic Solver 25% SIL-4 Contribution to PFD avg. Final Elements 45% Sensors 19% Logic Solver 36% Source: Oreda (Analysis of Safety Loop Failures) Source: Exida Shutdown Valves Selection of valves for HIPPS systems depends on reliability of the valve failure stroke, seat tightness, and impact of process conditions on valve drive train and seat design. A 1oo2 voting logic is normally specified for the HIPPS shutdown valves (in accordance with IEC 61511). Trunnion-mounted Ball Valves (TMBV) are preferred for HIPPS applications as they provide the best flow performance for shut down applications. Soft and metal seats can be offered. Triple-offset Butterfly Valves (TOBV), can be used in clean tight shutoff applications such as LNG where pressure drop is not a concern. The disc seat could either be a laminar seat or a solid seat based on the application. Product Range and Options Valve Types Trunnion Mounted Ball Valve Triple Offset Butterfly Valve Sizes 2 to 56 3 to 64 Pressure Rating Class 150 to 2500 Class 150 to 600 Temperature Range -196 C to 400 C -196 C to 538 C Seat Options Body Materials Actuation Options Metal-Graphite Laminated Seat, Soft Seat, Metal Seat Solid Metal Seat Carbon Steel, Stainless Steel, Duplex & Super Duplex Steels, Special Alloys, Carbon Steel with Stainless Steel/ Inconel Overlay Pneumatic and hydraulic. Fail safe position provided by spring return. 6

Features of Final Element: Certified to L&T Actuated TMBV and TOBV are certified to by an independent third party Partial Stroke Testing (PST) Partial stroke testing capability is built into each HIPPS shutdown valve, for testing (closure limited to 30%) and real time diagnostics. The PST data could be recorded with remote status indication in SCADA or an equivalent protocol. Fast Acting HIPPS valves designed to go from full open to full close in 2 seconds Tight Shut-off Leakage requirements as per Class V or VI of ANSI/ FCI 70-2 Fugitive Emission Meets ISO 15848-1 requirements Fire Safe Valves fire safe tested to API 607 or API 6FA 7

L&T Valves Limited Mount - Poonamallee Road, Manapakkam, Chennai 600 089, INDIA Tel. : + 91 44 2249 8201 Email: ContactUs@Lntvalves.com www.lntvalves.com CIN Number: U74999MH1961PLC012188 Registered Office: L&T House, N. M. Marg, Ballard Estate, Mumbai - 400 001, INDIA Publication Number: VB001/0714 As we continuously endeavour to improve our products, the data given herein is subject to change. Please refer www.lntvalves.com for the latest publication.