Architecture - Engineering - Planning www.mkcinc.com Mansfield, Ohio New Philadelphia, Ohio Powell, Ohio 9-55-0 - phone 0-6-887 - phone 70-657-0 - phone 9-55-8 - fax 0--075 - fax 70-657-77 - fax SHOP DRAWING REVIEW REVIEWED FURNISH AS CORRECTED REVISE AND RESUBMIT REJECTED SUBMIT SPECIFIED ITEM This review is only for general conformance with () the design concept and () the information given in the construction documents. Corrections or comments made on a shop drawing during this review do not relieve the contractor from compliance with the requirements of the plans and specifications. Approval of a specific item does not include approval of an assembly of which the item is a component. The contractor remains responsible for: dimensions to be confirmed and correlated at the job site; information that pertains solely to the fabrication process or to the means, methods, techniques, sequences and procedures of construction; coordination of the Work with that of all other trades; and performing all Work in a safe and satisfactory manner. Date: By: Jun 6, 0 Comments: Trane RTU- was chosen File Name: 7-0a-
Westlake City Schools Submittal Cover Sheet (To be filled out and submitted with each submittal) School High School Contractor: _Turner Logistics Date 0/9/ Item: RTU- Specification Section: 7 _ Sub Specification Section: Contractor s Submittal # 7-0 Revision # 0 Submittal Type PDF Lead Time After Approval (wks) _0 Manufacturer/Supplier: _Aaon_ Intended Area of Use, Drawing # and Detail Reference: Contractor Stamp CM Stamp APPROVED Aaon / Jacco Paul Hinman 0-9- TURNER/RESOURCE Reviewed for general acceptance only. This review does not relieve the Contractor of the responsibility for making the work conform to the requirements of the contract. The Contractor is responsible for all dimensions, correct fabrication and accurate fit with the work of other trades. SUBJECT TO ARCHITECT S APPROVAL Signed: Date: CM Submittal #: Architect Stamp Engineer Stamp
6 Milford Drive, Hudson, OH 6 Cleveland (0) 6-000 Akron (0) -900 Fax: (0) 6-00 http://www.jacco.com AAON SUBMITTAL DATA For Approval X For Record AHU- Job Name - Westlake City Schools New High School Contractor - Turner Engineer - Osborn Date - -- Submitted By: Billy Kodosky Focused On The Engineered Environment
6 Milford Drive, Hudson, Ohio 6 Cleveland: (0) 6-000 Akron: (0) -900 Fax: (0) 6-00 http://www.jacco.com Sold To: Turner Date: -- Project: Westlake City Schools New High School Location: Westlake, Ohio AHU- New High School Quantity Of One () AAON Model RN, Packaged Rooftop Air Handling Units, Complete With The Following: Cabinet Double Wall Foam Panel Construction (R-) w/ G-90 Galvanized Steel Construction w/ Polyurethane Paint Stainless Steel Drain Pan Outside Air Full Modulation Economizer, DDC Actuator Standard Pleated, Throwaway Filters Optional Merv- Final Filters Energy Recovery Section Energy Recovery Section w/ Heat Wheel & Pre-Filters Heat Section In-Direct Fired Natural Gas Heating w/ SS Heat Exchanger & Modulating Gas Heat Control Refrigeration Air Cooled Condenser Section Compressorized Refrigeration System R-0a w/ DX Cooling Coil Digital Scroll Compressor 0-00% Cooling Modulation Modulating Hot Gas Reheat w/ Digital Controller Fan Cycling Fans Direct Drive Supply Air Plenum Fan Assembly w/ ODP Premium Efficiency Motor o Factory Installed Variable Frequency Drive Power Exhaust Fan Assembly w/ ODP (Premium Efficiency) Motor o Factory Installed Variable Frequency Drive Electric & Controls Single Point Power Connection w/ Terminal Strip (Non-Fused NEMA- Disconnect Switch) & v Control Circuit Unit Wired For 60 / / 60 Power Field Installed DDC Controls By Others UV Light Provided And Installed By Jacco Warranty & Service Standard One () Year Limited Equipment Warranty Parts Only Five (5) Year Limited Compressor Warranty, Parts Only Twenty-Five (5) Year Limited Heat Exchanger Warranty, Parts Only Check, Testing & Start-Up Service First Year Labor Warranty Curbs & Accessories Knocked-Down, High, Non-Insulated Roof Curb & Duct Support Rails (Shipped Loose) Spring Vibration Rail (Shipped Loose) No Curb Insulation, Gasket Material & Fasteners, Nor External Vibration Isolators & Flexible Connectors (By Others) This Submittal Is For Equipment Only. Roof Curb, Controls, Airflow Measuring, & UV Lights Will Be Submitted Separately. Submitted By: Billy Kodosky
Unit Rating 5 South Yukon Ave - Tulsa, Oklahoma 707-78 - Ph. (98) 58-66 Fax (98) 58-609 AAONEcat Ver..8 (SN: 6989-7EPRFF) A B C D 5A 5B 5C 6A 6B 6C 7 8 9 0 A B 5 6 7 8 9 0 RN-08--0-EB0A-9:VEDE-E0B-DQG-AGC-CDCAHN-00-0000000AB Tag: Music VAV AHU- Job Information Unit Information Job Name: Westlake High Approx. Op./Ship Weights: 50 / 50 lbs. Job Number: Osborn Supply CFM/ESP: 570 / in. wg. Site Altitude: 0 ft Pre-Filter FV / Qty: 57.76 fpm / 6 Refrigerant R-0A Final-Filter FV / Qty: Exhaust CFM/ESP/TSP: Outside CFM: Ambient Temperature: Return Temperature: 57.76 fpm / 6 870 /.00 /.77 in. wg. 65 95 ºF DB / 75 ºF WB 75 ºF DB / 6 ºF WB Static Pressure External:.00 in. wg. Economizer: 0. in. wg. Evaporator: 0.5 in. wg. Heating: 0.5 in. wg. Filters Clean: 0. in. wg. Cabinet: 0.05 in. wg. Dirt Allowance in. wg. Heatwheel: 0.5 in. wg. Re-Heat Coil 0.0 in. wg. Total:.7 in. wg. Cooling Section Equivalent Total Capacity: Total Capacity: Sensible Capacity: Latent Capacity: HW Total Cooling Capacity: Mixed Air Temp: Entering Air Temp: Lv Air Temp (Coil): Lv Air Temp (Unit) Digital Comp. Capacity Ratio: Supply Air Fan: SA Fan RPM / Width: Exhaust Air Fan: EA Fan RPM / Width: Evaporator Coil: Evaporator Face Velocity: Energy Recovery Wheel: AHRI Listing Information Gross Net 06.7 MBH 90.99 MBH 07.9 9.0 MBH 56.50. MBH 50.69 MBH 98.98 MBH 79.9 ºF DB 65.8 ºF WB 79.9 ºF DB 65.8 ºF WB 5.07 ºF DB 5.97 ºF WB 5.66 ºF DB 5.06 ºF WB 00% x 70D60 @ 5. BHP /.6" x RM0A @.7 BHP 9 /.90" 9.9 ft² / 6 Rows / FPI 70. fpm x ERC-56C Cooling Capacity (MBH): 98.0 Cooling EER:. Cooling IEER:. Application EER @ Op. Conditions:. Electrical Data Heating Section PreHeat Type: Heating Type: Heating CFM: Total Capacity: OA Temp: RA Temp: Entering Air Temp: Leaving Air Temp: Input: Heater Qty: Consumption: Std (No Preheat) Nat. Gas Heat 570 8.7 MBH 0.0 DB / 0.0ºF WB 75.0 ºF DB / 6.0 ºF WB 57.9 ºF DB / 5.7 ºF WB 95.6 ºF DB / 65.7 ºF WB 70.0 MBH 70.0 MBH Re-Heat Coil: Capacity: 0 MBH LA DB / WB: 70.00 ºF / 59.0 ºF RH: 5% Rating: 60//60 Minimum Circuit Amp: 50 Unit FLA: 7 Maximum Overcurrent: 60 Qty HP VAC Phase RPM FLA RLA Compressor : 60.8 Condenser Fans: 0.75 60 075. Supply Fan: 7.50 60 760.0 Exhaust Fan:.00 60 760.8 Combustion: 0.5 60 00 0.9 Heatwheel: 0.667 60 760 0.6 Cabinet Sound Power Levels* Octave Bands: 6 5 50 500 000 000 000 8000 Discharge LW(dB): 9 9 9 9 88 88 89 85 Return LW(dB): 89 86 8 77 76 7 70 6 *Sound power levels are given for informational purposes only. The sound levels are not guaranteed. Date Created/Modified: /9/0 :8:8 AM Using Ver.8 (OSN# 6989) Date Printed: //0 :5:5 PM
Energy Wheel Rating 5 South Yukon Ave - Tulsa, Oklahoma 707-78 - Ph. (98) 58-66 Fax (98) 58-609 AAONEcat Ver..8 (SN: 6989-7EPRFF) A B C D RN-08--0-EB0A-9:VEDE-E0B-DQG-AGC-CDCAHN-00-0000000AB Tag: Music VAV AHU- 5A 5B 5C 6A 6B 6C 7 8 9 0 A B 5 6 7 8 9 0 Job Name Westlake High Heat Wheel Type: Total Job Number Osborn Heat Wheel Model: ERC-56C Site Altitude 0' Heat Wheel Qty: Summer Conditions Bypass: 0 CFM Mixed Air Damper Supply Air HW Outside Air 570 CFM 65 CFM 65 CFM 79.9 ºF DB 8.6 ºF DB 8.6 ºF 95.00 ºF DB 65.8 ºF WB 67. ºF WB 67. ºF 75.00 ºF WB 7.77 gr/lb 77. gr/lb 99.0 gr/lb Return Air From Space Exhaust Air 005 CFM 865 CFM 75.00 ºF DB 90.08 ºF 90.08 ºF DB 6.00 ºF WB 7.76 ºF 7.76 ºF WB 6. gr/lb 87.9 gr/lb 870 CFM Ex Bypass: 0 CFM Cooling/Dehumidification Heating/Humidification Total Capacity: 98.98 MBH 0.00 MBH Sensible Capacity: 7.6 MBH 0.00 MBH Latent Capacity: 5. MBH 0.00 MBH Winter Conditions Bypass: 0 CFM Mixed Air Damper Supply Air HW Outside Air 570 CFM 65 CFM 65 CFM 58.7 ºF DB 8. ºF DB 8. ºF 0.00 ºF DB 5.00 ºF WB.98 ºF WB.98 ºF 0.00 ºF WB 7.9 gr/lb 9.7 gr/lb 5.5 gr/lb Return Air From Space Exhaust Air 005 CFM 865 CFM 75.00 ºF DB 8.5 ºF 8.5 ºF DB 6.00 ºF WB 8.5 ºF 8.5 ºF WB 6. gr/lb.80 gr/lb 870 CFM Ex Bypass: 0 CFM Frost Warning - Conditions for frost forming on the energy recovery wheel exists. Outside air preheat is required to prevent frost formation. Optionally, the return air humidity ratio could be lowered to prevent frost formation. See AAON literature titled 'AAONAIRE ENERGY RECOVERY' for details. Cooling/Dehumidification Heating/Humidification Total Capacity: 0.00 MBH 5.89 MBH Sensible Capacity: 0.00 MBH 75.6 MBH Latent Capacity: 0.00 MBH 78.7 MBH Date Created/Modified: /9/0 :8:8 AM Using Ver.8 (OSN# 6989) Date Printed: //0 :5:5 PM
7.0" STAR Plenum 5 South Yukon Ave - Tulsa, Oklahoma 707-78 - Ph. (98) 58-66 Fax (98) 58-609 AAONEcat Ver..8 (SN: 6989-7EPRFF) JOB INFORMATION: WHEEL SPECIFICATION: Job Name: Westlake High Max RPM:,800 Job Tag: Music VAV AHU- Diameter x Qty: 7. in. x Rep Firm: Width%: 99 Date: 0/0/0 Tip Speed: Inertia: 0,5 FPM 6 WR² OPERATING CONDITIONS: MOTOR SELECTION: Air Flow: 5,70 CFM Rated HP / Bypass: 7.5 / No Static Pressure:.7 in. Wg. Frame Size: T Plenum DP: 0.00 in. Wg. Nominal RPM: 760 Inlet Grill DP: 0.00 in. Wg. VAC/PH/HZ: 60//60 TSP:.7 in. Wg. Efficiency Premium / 0.9 Site Altitude: 0.00 Ft Enclosure Type: ODP TSP @ Sea Level:.7 in. Wg. Max Inertial Load: 6 WR² FAN PERFORMANCE: FAN SOUND POWER (Inlet/Outlet): RPM: Octave Band: (Re 0^- watts) BHP: 5. 5 6 7 8 Efficiency: 68.% 9 88 85 85 8 8 8 8 In/Out Velocity: 0/67 FPM 9 9 9 9 9 9 9 88 Plenum Out Velocity: 89 FPM SOUND POWER A-Weighted: 9 / 99 db Supply Fan Model: 70D60 @ RPM and 99% Width Design Conditions: 570 CFM @.7" SP RPM: 60% RPM BHP SYSTEM Efficiency 0 9 SP 0% 8 EFFICIENCY: 68.6 7 6 BHP 5 BHP: 5. 0% 0 5 CFM x 000 6 7 0% 8 0 Date Created/Modified: /9/0 :8:8 AM Using Ver.8 (OSN# 6989) Date Printed: //0 :5:5 PM
.0" STAR Plenum 5 South Yukon Ave - Tulsa, Oklahoma 707-78 - Ph. (98) 58-66 Fax (98) 58-609 AAONEcat Ver..8 (SN: 6989-7EPRFF) JOB INFORMATION: WHEEL SPECIFICATION: Job Name: Westlake High Max RPM:,00 Job Tag: Music VAV AHU- Diameter x Qty:.0 in. x Rep Firm: CFM: 870 Date: 0/0/0 Tip Speed: Inertia: 7,770 FPM 5 WR² OPERATING CONDITIONS: MOTOR SELECTION: Air Flow:,870 CFM Rated HP / Bypass: / No Static Pressure:.6 in. Wg. Frame Size: 8T Relief Dampers DP: 0. in. Wg. Nominal RPM: VAC/PH/HZ: 760 60//60 TSP:.77 in. Wg. Efficiency Premium / 0.895 Site Altitude: 0.00 Ft Enclosure Type: ODP TSP @ Sea Level:.77 in. Wg. Max Inertial Load: 9 WR² FAN PERFORMANCE: FAN SOUND POWER (Inlet/Outlet): RPM: 9 Octave Band: (Re 0^- watts) BHP:.7 5 6 7 8 Efficiency: 6.8% 89 87 89 8 78 77 7 67 In/Out Velocity: 89/60 FPM 89 87 89 8 78 77 7 67 Plenum Out Velocity: 8 FPM SOUND POWER A-Weighted: 89 / 89 db Exhaust Fan Model: RM0A @ 9 RPM and 00% Width Design Conditions: 870 CFM @.77" SP 60% 5 RPM BHP SYSTEM Efficiency RPM: 9 EFFICIENCY: 6.8 0% SP BHP BHP:.7 0% 0 CFM x 000 5 0% 6 0 Date Created/Modified: /9/0 :8:8 AM Using Ver.8 (OSN# 6989) Date Printed: //0 :5:5 PM
Unit Submittal 5 South Yukon Ave - Tulsa, Oklahoma 707-78 - Ph. (98) 58-66 Fax (98) 58-609 AAONEcat Ver..8 (SN: 6989-7EPRFF) A B C D RN-08--0-EB0A-9:VEDE-E0B-DQG-AGC-CDCAHN-00-0000000AB Tag: Music VAV AHU- 5A 5B 5C 6A 6B 6C 7 8 9 0 A B 5 6 7 8 9 0 Job Name: Westlake High Unit Submittal For: Job Number: Osborn Unit Submittal Date: November 9, 0 Base Option Description R Series Roof Top Unit N Generation Ninth Generation 08 Unit Size Eighteen Voltage 60V/Ø/60Hz 0 Interior Protection Standard E Refrigerant Style R-0A Variable Capacity Scroll Compressor (VCC) B Unit Configuration Air-Cooled Cond. + 6 Row Evap. Coil 0 Coil Coating Standard A Cooling/Heat Pump Staging Modulating - All Variable Capacity Compressors Heating Type Natural Gas Stainless Steel Heating Designation Heat - 70 MBtuh 9 Heating Staging Modulating Gas - Temperature Control Feature Option Description V A. RA/OA Section AAONAIRE Energy Recovery Wheel + Bypass Damper - Total + High CFM E B. RA/EA Blower Configuration Blower + Premium Efficiency Motor + VFD D C. RA/EA Blower " Backward Curved Plenum E D. RA/EA Blower Motor.0 hp - 760 rpm E. OA Control DDC Actuator 0. Heat Options Standard B. Maintenance Options 5V Convenience Outlet - Factory Wired D 5A. SA Blower Configuration Blower + Premium Efficiency Motor + VFD Q 5B. SA Blower 7'' Direct Drive Backward Curved Plenum - 60% Width G 5C. SA Motor 7.5 hp - 760 rpm A 6A. Pre Filter Type " Pleated Pre Filter - 0% Eff G 6B. Unit Filter Type " Pleated - 85% Eff - MERV C 6C. Filter Options Clogged Filter Switch + Magnehelic Gauge C 7. Refrigeration Control Fan Cycling D 8. Refrigeration Options Modulating Hot Gas Reheat C 9. Refrigeration Accessories Sight Glass + Compressor Isolation Valves A 0. Power Options Power Switch - 00 amps H. Safety Options Remote Safety Shutdown Terminals N. Controls ERW Defrost + ERW Rotation Detection. Special Controls VAV Single Zone Unit Controller - VAV Cool + VAV Heat 0 A. Preheat Configuration Standard - None 0 B. Preheat Sizing Standard - None 0 5. Glycol Percent Water or No WSHP 0 6. Interior Cabinet Options Standard - Double Wall + R- Foam Insulation + Stainless Steel Drain Pan 0 7. Exterior Cabinet Options Standard 0 8. Customer Code Standard 0 9. Code Options Standard - ETL U.S.A. Listing 0 0. Crating Standard 0. Water-Cooled Cond. Standard - None A. Control Vendors Wattmaster Controls B. Type Standard - Includes AAON Gray Paint Date Created/Modified: /9/0 :8:8 AM Using Ver.8 (OSN# 6989) Date Printed: //0 :5:5 PM
VCMX Components 5 South Yukon Ave - Tulsa, Oklahoma 707-78 - Ph. (98) 58-66 Fax (98) 58-609 AAONEcat Ver..8 (SN: 6989-7EPRFF) A B C D RN-08--0-EB0A-9:VEDE-E0B-DQG-AGC-CDCAHN-00-0000000AB Tag: Music VAV AHU- Job Name: Westlake High VCMX For: Job Number: Osborn VCMX Date: November 9, 0 5A 5B 5C 6A 6B 6C 7 8 9 0 A B 5 6 7 8 9 0 Hardware Included For VCMX Controller Part # Included Parts Assigned Channel V0750 VCMX Controller with EBUS P90 Space Temp Sensor - Field Installed MainController\AI R8890 Supply Air Temp Sensor - Field Installed MainController\AI R8890 Return Air Temp Sensor MainController\AI R8550 Outside Air Temp Sensor MainController\AI R6990 VCMX Large Expansion Module R700 Building Static Pressure Sensor LargeExpansionModule\AI P650 Proof of Flow Sensor LargeExpansionModule\BI P650 Dirty Filter Sensor LargeExpansionModule\BI R690 Space Humidity Sensor - Field Installed LargeExpansionModule\AI R7870 VCMX Full Digital Module R890 Suction Pressure Transducer VCMX Controller with EBUS 5 6 7 Analog In X X X X Analog Out X X Binary In Relay Out X X X X X Digital Sensor(s) VCMX Large Expansion Module 5 6 7 8 Analog In X X Analog Out Binary In X X X Relay Out Date Created/Modified: /9/0 :8:8 AM Using Ver.8 (OSN# 6989) Date Printed: //0 :5:6 PM
Date Created/Modified: /9/0 :8:8 AM Using Ver.8 (OSN# 6989) Date Printed: //0 :5:6 PM
Date Created/Modified: /9/0 :8:8 AM Using Ver.8 (OSN# 6989) Date Printed: //0 :5:6 PM