Bunch Length Interferometer System

Similar documents
SPECTRAL INSTRUMENTATION

MODEL-BASED OPTIMIZATION OF AN INFRARED GAS SENSOR

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

Technical specifications of FT-IR Spectrometer

FTIR-OEM IR source, interferometer & detector modules for modular and OEM applications

The Optical Scattering Calibration System at SNO+ IOP 2015

An FT-NIR Primer. NR800-A-006

Laser Diagnostics and Optical Measurement Techniques

This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore.

Optical Time Domain Reflectometry (OTDR)

高等食品分析 (Advanced Food Analysis) II. INSTRUMENTS FOR OPTICAL SPECTROSCOPY *Instruments for optical spectroscopy: Optical spectroscopic methods are

Doc. No. SP R0. CXI Detector stage. Prepared by: Signature Date Jean-Charles Castagna Design Engineer

Understanding total measurement uncertainty in power meters and detectors

Copyright 2017 by Lasermate Group, Inc.. All rights reserved.

OIL FILM DETECTOR (Flame-proof Version) SODL-1600

Content. Laser physics Laser treatment parameters Laser safety. by Fotona d.o.o., 2017

AUBURN UNIVERSITY X-RAY SAFETY STANDARD OPERATING PROCEDURES

Laser Safety Products. Edition 20

Chapter 1. Introduction

The FEL Facility Optical Diagnostics and FEL Characterization

Montanez, Boutet, Fox, Van Campen, Hays, Woods

Physics Requirements for the CXI Detector Stage

North Dakota State University Laser Safety

Information for Proper Posting & Laser Area Sign Templates

SECTION 1: STARTING 1.1 UNPACKING AND INSPECTION

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

Identify the key elements of the laser source, regardless of the type of measurement or sensor required;

Instruction Manual. Self-Leveling Rotary Laser Level Model Nos and

FIRERAY 5000 range USER GUIDE

FLIM/FFS and Nanoimaging Upgrade of Olympus confocal microscopes

Low-Frequency Raman Spectroscopy Enabling Affordable Access to the Terahertz Regime

HiRadMat facility at the CERN SPS

InfinityLab Quick-Connect Bio-inert Heat Exchanger

Eurys Series. User Guide. Broadband Faraday Rotators & Optical Isolators Small Aperture (5mm)

Measuring THz Radiation choose a Pyroelectric Detector or Golay Cell?

FEATURE ARTICLE. The PLCA-800 Series Inline Particle Sensor for Chemical Solutions. Yoshihito Yuhara. Abstract

WHAT IS LASER ULTRASONIC TESTING?

Approved by Principal Investigator: Date: Approved by Laser Safety Officer: Date:

Radiation and Laser Safety

QIAcube HT Unpacking and Installation Instructions

Victoreen & 660-8

Laser Distance Sensor Type M Analog-Output

Modular: available in any length Current monitoring & error detection Wavelengths: from UV to Visible and IR. LOTUS Line lights

UC IRVINE LASER SAFETY NEWSLETTER

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No &

MME Standard Operating Procedure (SOP)

Carnegie Mellon University Radiation Safety Committee

PART V: WORKING WITH LASERS

Doc. No. SP R0. CXI Reference Laser. Prepared by: Jean-Charles Castagna Signature Date Design Engineer

Specifications Wavelength Range: 190 nm to 800 nm continuous

Compact Raman spectrometer system for low frequency spectroscopy

SAM. Interface Robot & Trainer Board. User Guide V0211

clear & preserve vision OptoYag&SLT

MOXTEK MULTI-LAYER OPTICS AND X-RAY TECHNOLOGY

Illustra Essentials HD IR Vari-Focal Dome Network Camera Quick Start Guide

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

CALIFORNIA INSTITUTE OF TECHNOLOGY LASER SAFETY MANUAL. January, 1998

Hands-On Laser Beam Path Alignment Practical. Environment, Safety, Health & Quality Office SERF E141 Last updated: 12/28/2017

Thermal Stripper, TSFB-125 User Manual

OPTICAL TIME DOMAIN REFLECTOMETRY (OTDR) Dr. BC Choudhary Professor, NITTTR, Chandigarh

Laser Damage Measurements

M15-GSL12P30 M15-GSL12P30S Heat Spy Infrared Thermometer User Manual

This is to certify that the optical output of the: SENSORNET LR-DTS Temperature Sensing System: (Variants Mark 1, Mark 2a and Mark 2b)

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

Appendix C X-Ray Diffraction User s Guide and Approval Form

Instruction Manual E4 ChamberIR Heater

Rice University Laser Safety Manual

Installation & Service Manual. Models ALF 20, 30, 40, 50, 60, 80

CL3 HYBRID MULTI-LINE LASER INSTRUCTION MANUAL

Modular LIBS System. User s Manual. May 2015 Doc. Ref.: UM/ /02

OIL FILM DETECTOR (Long-distance correspondence Version)

Table of Contents. Check the LCLS Project website to verify 2 of 12 that this is the correct version prior to use.

Optical Time-Domain Reflectometry for the Transport Spatial Filter on the OMEGA Extended Performance Laser

Electronic Self-Leveling Horizontal Rotary Laser Level Model No Instruction Manual

SYNCHROTRON RADIATION ABSORPTION AND VACUUM ISSUES IN THE IR*

Modular: available in any length Current monitoring & error detection Wavelengths: from UV to Visible and IR. LOTUS Line lights

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL

Laser Safety Self-Audit Checklist

WG Container & Cargo X-Ray Scanning Portal

A. Administrative. B. Labeling and Posting. C. Control Measures. Laser Safety Self-Audit Checklist. Building Room Principal Investigator Date

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No , &

Chemistry Instrumental Analysis Lecture 14. Chem 4631

LASER SAFETY. Class 2 and 2a - low power, low risk Class 2 and 2a lasers have low power and emit visible light. They will cause harm if viewed

SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION

DEVELOPMENT OF THE INFRARED INSTRUMENT FOR GAS DETECTION

Analisi del Focus-shift su sorgenti multikw. Luca Porcelluzzi Ophir Spiricon Europe GmbH

Hazard Analysis, Mitigation, and Operating Procedures for (Laser name) Laser

Laser Use at Subaru Telescope (NAOJ) Laser Safety Policy

Title: Laser Safety Effective Date: 9/91 Revision: 2/97 Number of Pages: 7

LASER INTERFEROMETER GRAVITATIONAL WAVE OBSERVATORY - LIGO - CALIFORNIA INSTITUTE OF TECHNOLOGY MASSACHUSETTS INSTITUTE OF TECHNOLOGY

XEUS mirror calibration:

Magneplanar 20.7 Instruction Manual

Beam Loss Position Monitoring with Optical Fibres at DELTA

Development of a variable output LED-365 irradiance standard

Low-Power Detectors. Key Features. 818 Series. Power levels from pw to 2W. Wavelengths from 190 nm to 1800 nm. Proprietary detector optics

Thermal Stripper, TSAB-40 User Manual

Wavelengths: From UV to Visible and IR COBRA TM Max

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

ProStar Ceiling Fan PS52. Installation Instructions Instrucciones de instalación Instructions d installation

Transcription:

Bunch Length Interferometer System Thank you for purchasing the RadiaBeam Bunch Length Interferometer System (BLIS). This manual will give you some basic guidelines for the installation of the device. We have also included a paper detailing the experimental procedure and data analysis. Please contact us at (800) 589-7001 with any questions or support needs. CAUTION!!! The beamsplitters used in the BLIS are very fragile. Never touch them, and use extreme caution when working around them. 1. Operating principle The BLIS is a compact THz interferometer designed for the autocorrelation of the intense, sub-mm and mm-wavelength, spatially-coherent radiation pulses. Before operating BLIS the user must obtain 1 or 2 THz detectors, of which the most common room-temperature operated devices are Golay cells. While the BLIS geometry is prearranged to install Golay cells, it can be easily adapted for other types of bolometers or pyroelectric detectors.

The device schematics (above) include the following components: 1. 45 -beamsplitter 2. 90 -beamsplitter 3. Front surface mirror on translation stage 4. Detector focusing mirror 5. Reference detector focusing mirror The incoming spatially coherent THz radiation pulse, I(t), initially amplitudesplits at the 45 -beamsplitter (1). The transmitted component split again at the 90 beamsplitter (2) and recombines with the other initially reflected component, which has subsequently been reflected off the mirror (3), which is attached to the translation stage. The path-length difference between the two arms, τ, can be varied by moving the translation stage. By systematically measuring the signal at the detector for different values of τ, one can obtain the autocorrelation function of the input pulse: ( ) " I ( t) I ( t +! ) S! # dt The intensity of the fraction of the input pulse transmitted through the 90 beamsplitter can be measured with the reference detector, allowing normalization of the intensity at the autocorrelation detector. The reference detector option is strongly recommended in situations with significant shot-to-shot fluctuations in the intensity of the incoming pulse.

Due to the strong diffraction anticipated at the longer-wavelength end of the THz spectrum, the BLIS system was engineered to be very compact, in order to minimize losses and errors in the measurements. 2. Basic installation The BLIS can be used with or without nitrogen flow. For information about the steps necessary for nitrogen-flow operation, see Section 3. In this section, the basic installation steps are discussed. It is critical for the proper operation of the BLIS to have an input THz pulse collimated before the interferometer entrance. Typically, when dealing with sources of small spatial extent (e.g. coherent transition radiation), this collimation is achieved with the focusing parabolic mirror approximately one focal length removed from the source. It is generally recommended to install BLIS as close to the source as possible, enabling use of relatively short focal length collimating mirrors (EFL = 15-30 cm). Both output ports of the device include focusing 90 parabolic mirrors (4,5) to maximize the signal at the detectors. To optimize the error-tolerance, the focusing mirrors are chosen to have a very small focal length (EFL = 50.8 mm). Note: if one chooses to use larger detectors (such as cooled bolometers, in the case where signal strength demands it), which may not be positioned at the focal spots of the parabolic mirrors, we recommend that the user does not replace the mirrors (4,5) but rather builds an additional transport line from the original BLIS mirror focus towards the detector entrance. The Translation Stage is operated with a Newport ESP100 Controller. Connect the cable from the BLIS to the Axis 1 connector on the back of the ESP100. The ESP100 communicates through RS232 with a computer and should be connected to the computer with a standard serial cable (not a null-modem cable). The ESP100 comes with a CD-ROM which includes an operating manual and some useful programs. The user may communicate directly through RS232 with commands, or use the ESP-Util program to control the motion of the stage. Note: the ESP-Wizard program should first be used to generate an initialization script for the stage, MFN25-PP. Then this script should be

opened in ESP-Util or sent directly via RS-232 to begin operation with the controller. Please see the manual (on the ESP100 CD-ROM) for more information. While all the components of BLIS are pre-aligned by the manufacturer, the user should check the alignment of the system when it is placed in the location at which it will be used. For this purpose there is an alignment laser integrated into BLIS at the location of the focusing mirror (4). The mirror has a small hole at the center to allow a laser beam to be injected backwards into the system. There are 3 basic steps: 1. Insert the alignment laser into its holder, behind focusing mirror (4). Point the BLIS so that it s input port is facing a flat white surface (i.e., a wall), at least 1 meter away. Turn the laser on. If only one spot is visible on the wall, then the alignment is acceptable, and no adjustment needs to be done in this step. If there are two spots, then continue to align the internal optics. The bright spot is the laser reflected off mirror (3) and beamsplitter (1). The dim spot is the laser reflected from beamsplitter (1) to beamsplitter (2), and then transmitted back through beamsplitter (1). Remove the lucite tube containing the reference focusing mirror (5) (be careful not to touch the beamsplitter). You will see three set screws in the wall of the BLIS, which control the alignment of beamsplitter (2). Adjust these set-screws with a 5/64 hex wrench until the two spots overlap. Now both beamsplitters and the front surface mirrors are aligned with respect to each other. 2. Now the alignment laser is used to properly position the focal point of the focusing mirrors (4) and (5) at the detector entrance port. First place the detector(s) in position. If the laser spots hit the detector window(s) correctly then proceed to the next step. If not, rotate the focusing mirror until the reflected laser spot hits the center of the detector. The mirror is held by one 1/4-20 bolt; this must be loosened with a 3/16 hex wrench. Then, using a finger (use gloves) inserted into the hole cut in the lucite tube, the mirror can be rotated, and the bolt re-tightened when in correct position.

3. By either translating the whole device, or by manipulating transport/collimating mirrors (not included into the BLIS), make sure that the alignment laser beam is guided towards the source of the input THz pulse, at the appropriate angle. Now that the optics are aligned and the detectors are in place, the user may carry out the measurement. Warning!!! For the CTR bunch length measurements with BLIS and Golay cells, one has to minimize detectors exposure to x-rays. Excessive irradiation will degrade Golay cells performance prematurely. 3. Nitrogen-flushed installation In the THZ spectrum range of interest there are numerous intense water vapor absorption lines. It is strongly recommended while using BLIS to nitrogen-flush the whole transport-blis system. The user must design their transport system to be nitrogen sealed. For convenience, an extension of the BLIS from the input port is designed to attach to a 3.5 OD tube. If the end of user s transport line is designed to be 3.5 OD tube, it can be inserted into the BLIS input port and secured with 1/4-20 bolts. This will complete the nitrogen seal from the transport line to the BLIS. The nitrogen connection must be included in the user s transport line. The nitrogen will then flow through the transport line, through the BLIS, and exit through the alignment laser hole in reference mirror (4). Warning!!! The nitrogen flow should be very gentle, as low as possible to ensure that, while water vapor is being evacuated from the system, there is no significant pressure differential around the beamsplitters. The beamsplitters are very fragile and small pressure/flow will break it. Once the transport system has been installed, the steps of Section 2 (above) can be followed to complete the setup.