Vitodens 100W WB1B - Service and Maintenance

Similar documents
Detailed Cleaning Instructions

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

Applications and Piping Strategies for Condensing Boilers - Introduction

Raptor 320HB & 399HB Submittal Sheet

Model SSV-399 GAS BOILER PARTS, KITS & OPTIONAL ACCESSORIES

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners

GB Condensing Gas Boiler

TECHNICAL INSTRUCTIONS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

40 SERIES GAS BURNER MODEL 400 NATURAL GAS/PROPANE INSTALLATION INSTRUCTIONS AND OWNER S HANDBOOK

GB Condensing Gas Boiler

National Comfort Products 539 Dunksferry Road Bensalem, PA (215) Fax: (215)

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

TECHNICAL INSTRUCTIONS

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

Vitocrossal 300, CU3A - Introduction

Q - Series Boiler. Troubleshooting Manual

TECHNICAL INSTRUCTIONS

ClearFire - Hydronic Startup Report

ProCon Streamline Gas Condensing Boiler. Installation and Operating Manual.

SCN60 Residential Nugget Ice Machine

Suggested Specifications Prestige Excellence 110

VIESMANN. Service instructions VITOLADENS 300-T. for contractors. Vitoladens 300-T Type VW3B Inox-Radial heat exchanger for oil fired condensing Unit

NAVIEN AMERICA INC FITCH AVENUE IRVINE, CALIFORNIA, USA

Forced draught natural gas/propane burner

VIESMANN. Service instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

A Better Boiler Just Got Better. Better Boilers. New Size Available. Express Setup. Load Status. User Setup. Installer Setup. Diagnostics.

Up to 94.6% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER

Oil TRIANCO. EuroStar Range BURNER DETAILS TRIANCO - OIL BURNER. To be retained by householder

BAXI LUNA 310 Fi TECHNICAL INFORMATION

Automatic Circulating Water Heaters

USER S INFORMATION MANUAL

Indirect gas-fired air heater

SAFETY AND OPERATING MANUAL

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

Ultra Boiler Series 1 & 2 Jacket Parts

COMMERCIAL MODELS: XTHERM 1005 THROUGH 2005

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

UTICA BOILER. SSV Submittal. Project Name: Project Location: Contractor:

Viessmann Academy Seminar Vi 101, Introduction to Viessmann

Statement of Responsibilities

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

VIESMANN. Service instructions VITODENS 200-W. for contractors

RAYPAK ILLUSTRATED PARTS LIST

Mikrofill Ethos Condensing combination boiler. Maintenance Instructions 24cc

Technical Data Manual Model Nos. and pricing: see Price List

TECHNICAL INSTRUCTIONS

TECHNICAL INSTRUCTIONS

Low Water Cutoff (LWCO) IQ Option Card p/n , for Hot Water Boilers

New Power Vented Rheem FVIR Tanks

Technical Data Manual

Energy-Efficient, Environmentally-Friendly Heating Solutions. Baxi Luna HT Residential Troubleshooting Guide

Single stage operation forced draught natural gas/propane burner

Gas-Fired Condensing Boilers A Green Start to Space & Water Heating

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-400 INDIRECT FIRED SPACE HEATERS

Preventative Maintenance Tables

PRO 2000i LOW LEVEL DEPOSITOR

VSL II QUICK START GUIDE

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

GP COMBUSTION EQUIPMENT INC 100 Sheldon Dr., Units 16/17 Cambridge, Ontario N1R 7S7. Model C Forced Draft Burners. Natural Gas or Propane MODEL C10

WATER-TUBE POOL HEATERS

TECHNICAL INSTRUCTIONS

C1210ES Tankless Water Heater

VIESMANN. Installation and service instructions VITODENS 111-W. for contractors

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

USER S INFORMATION MANUAL (2,4)SG13B

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

User s Information Manual

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

WATER-TUBE POOL HEATERS

Owner s Guide Installation & Operation

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model MICROGENUS PLUS. R EN - Edition 02-01/04/2007

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers

Bosch Buderus SSB800/1000/1000TL Stainless Steel Condensing Boiler

Engineer: Project Name: Project Location: Contractor:

Bosch Greentherm T9800 SE 199 Gas Tankless Water Heater

Owner s Guide Installation & Operation

AFUE 95% Heating Input 50,000 to 200,000 Btuh

Highlights MBH 95% efficiency ENERGY STAR Qualified Low NOx emissions Space-saving design. 95% Efficient. Modulating Technology

INSTALLATION AND MANINTENANCE INSTRUCTIONS

OR Replacement Instructions Heat Exchanger Assembly, ASME

VSL II QUICK START GUIDE

DOMESTIC HOT WATER Follow operational sequence

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

Mascot. Gas-Fired Residential and Commercial Wall-Mounted Boiler. Easy Installation, 96% Efficiency, Fully Condensing

DIVISION FINNED WATER-TUBE BOILERS

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

WD7664 / WD7663 Maxon Burner Ellis Whisper Dryer Installation & Start UP

Project Name: Location: Engineer: Contractor: I. GENERAL

Service manual. Riva Plus HE. M296.28SR/C System boiler. Wall hung, fanflue, roomsealed, high efficiency gas boiler

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

External Module Floor Standing Condensing Oil Boiler Range ADDENDUM ATTENTION INSTALLERS - UPDATED INFORMATION!

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model CLAS. R EN - Edition 01-01/02/2007

KGA092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

Universal Fire Tube Boiler Wall Mount Models

DIVISION FINNED WATER-TUBE BOILERS

Electronic Ignition Water Heater

Installation and User Manual for Model UF424 and UN324

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

Transcription:

- Service and Maintenance

Foil 2, 11/2015 Viessmann Manufacturing W 10-26: 37-91 MBH input. W 10-35: 37-118 MBH input. Natural Gas or LPG (conversion kit supplied with boiler). Altitudes up to 10,000 ft. (coding change required). Temperature range 86 F - 178 F. Venting up to 200 equivalent length. Outdoor reset, & OpenTherm control compatible.

Foil 3, 11/2015 Viessmann Manufacturing Locating the boiler model number Located on the rating plate mounted on the left side of the outer cover.

Foil 4, 11/2015 Viessmann Manufacturing Locating the boiler serial number Located inside the outer cabinet on the left side of the burner compartment

Foil 5, 11/2015 Viessmann Manufacturing Removing The Boiler Cover There are two screws 1 holding the cover in place. Loosen the screws before removing the cover (screws are captive and will remain in the boiler). Flip up the control cover panel and lift the cover off.

Foil 6, 11/2015 Viessmann Manufacturing Checking The Flue Collar And Flue Gas Sensor Gaskets Inspect the flue gas collar gasket and the flue gas temperature sensor to make sure the seal is still good, and they are still positioned correctly. If either of these are damaged or misaligned, flue gas can enter the burner cabinet and cause damage.

Foil 7, 11/2015 Viessmann Manufacturing Parts List The service manual contains drawings that help to identify the boiler s components. The parts catalogue available as a PDF download on the Viessmann Canada website will also provide the current part number for these components.

Foil 8, 11/2015 Viessmann Manufacturing Piping Connections 30 psi PRV Boiler service drain/purge valve Gas 3/4 NPT Boiler service fill/purge valve 3/4 NPT 3/4 NPT

Foil 9, 11/2015 Viessmann Manufacturing Automatic Air Vent And Air Scoop Serviceable automatic air vent. Isolate the boiler s supply and return connection. Drain the water from the heat exchanger (~1US Gal). Remove the hand tight air vent.

Foil 10, 11/2015 Viessmann Manufacturing Servicing The Automatic Air Vent The air vent can be disassembled by pushing down on the top locking ring and turning the locking ring off. Lift the top off the vent and disassemble the insides for cleaning. Usually a good rinse in a sink will be sufficient to remove deposits that can prevent the float from being buoyant. Reassemble in the reverse order. Make sure not to damage the O-ring on the base. The vent is tightened hand tight into the air scoop. Locking Ring O Ring

Foil 11, 11/2015 Viessmann Manufacturing Servicing The Condensate Trap The condensate trap should be inspected and if debris has built up inside, it should be removed and flushed clean. A dirty trap can lead to backed up condensate that can prevent the burner from operating.

Foil 12, 11/2015 Viessmann Manufacturing Cleaning the condensate trap Disconnect the hoses attached to the trap and remove for cleaning. If you expect to flush the fireside of the heat exchanger with water remember to clean the trap afterwards.

Foil 13, 11/2015 Viessmann Manufacturing Cleaning the condensate trap The trap needs to be re-primed after the service is complete before the boiler is put into service. Minimum of 10 Fl. oz. (0.3 Ltr) of water is required to prime the trap. Sports bottle can be used to put water into combustion air test port

Foil 14, 11/2015 Viessmann Manufacturing Condensate Drain Line Make sure the flexible condensate drain line is terminated into a larger pipe so it can breath. Piping the trap rigid into a waste drain without an air gap may cause the trap to not siphon correctly. Air Gap required, Do Not pipe rigid to drain Condensate Hose

Servicing Burner And Heat Exchanger Service, Web Based Training Foil 15, 11/2015 Viessmann Manufacturing

Foil 16, 11/2015 Viessmann Manufacturing Burner Service Close the gas service isolation valve before removing the burner. The gasket between the gas line and gas valve should be replaced any time that connection is opened. Fully modulating burner input for either Natural Gas or Propane. Service to the burner is recommended annually, especially when operated with LP Gas. Cylinder burner Ignition & Ionization electrode Burner Refractory Burner seal gasket Gas valve Premix blower assembly

Foil 17, 11/2015 Viessmann Manufacturing Burner Service Place the burner on a clean dry surface. Inspect components: Refractory (flaking is normal, cracks are a sign of damage). Cylinder (look for hotspots or damage to the mesh). Electrode Clean the burner and electrode with a non-metallic brush. Use a vacuum as required (compressed air can push surface dirt into the burner). Gasket (if cracked or brittle, replace)

Foil 18, 11/2015 Viessmann Manufacturing Cleaning And Inspecting The Electrode The electrode gap and spacing should be checked when the electrode is inspected and cleaned. Checking the porcelain for cracks can be done at the same time. Do not use a metallic object to clean the electrode as this will reduce the life of the electrode. It may be necessary to remove the electrode for cleaning. Do not damage the gasket. Replace the electrode if it cannot be cleaned with a non metallic brush

Foil 19, 11/2015 Viessmann Manufacturing The Heat Exchanger High grade 316Ti stainless steel. 1.5 mm wall thickness. Compact radial design. Intensive heat transfer with single pass. Flue gas gaps via material embossed pins on coil. 45 PSIG MAWP * * Shipped with 30 PSIG PRV standard. Designed and manufactured by Viessmann in Germany

Foil 20, 11/2015 Viessmann Manufacturing The Heat Exchanger Condensation occurs on the outside of coil. Self-cleaning on condensing surface of heat exchanger. Narrow gap width 0.8 mm + or 0.01mm. Flue gas Condensate

Foil 21, 11/2015 Viessmann Manufacturing Cleaning The Heat Exchanger Using a NON-Metallic brush clean the loose deposits from the heat exchanger. A vacuum can aid in removing the dirt from the heat exchanger (compressed air may push the dirt further into the coil).

Foil 22, 11/2015 Viessmann Manufacturing Viessmann Coil Cleaning Tool It may be necessary if the heat exchanger is severely plugged to use the Viessmann coil cleaning tool. Use a vacuum to assist removing the debris from the heat exchanger. Part # 7840 112

Foil 23, 11/2015 Viessmann Manufacturing Cleaning The Heat Exchanger Severe deposits or staining that cannot be removed with a brush and vacuum can be removed with a chemical cleaning. Follow Material Safety Data Sheet (MSDS) of the cleaning agent manufacturer. Cleaning agents must not contain hydrocarbon-based solvents or potassium. If required remove coatings and (yellowish brown) surface discoloration with phosphoric acid based Antox 75 E Plus, or citric acid based CitriSurf 3050 by Stellar Solutions Inc. Rinse thoroughly with water.

Foil 24, 11/2015 Viessmann Manufacturing Before You Reassemble And Fire The Boiler Be sure to clean the condensate trap after flushing the dirt from the heat exchanger. If the refractory has gotten very wet, dry it with a hair dryer or heat gun before firing the burner.

Foil 25, 11/2015 Viessmann Manufacturing Minimum & Maximum Flow Requirements There are minimum and maximum flow rates specified for the boiler. Flow rates below the minimum may not allow the flow proving switch to close. Flow rates above the maximum will effect the boiler efficiency by reducing the delta T. T-T

Foil 26, 11/2015 Viessmann Manufacturing Primary / Secondary Piping For Low Mass Boilers It is always recommended, with low mass boiler such as the Vitodens 100, that a primary / secondary piping layout is used. This ensures correct flow through the boiler at all times. Hydraulic system decoupling with Low Loss Header Vitodens Primary Secondary

Foil 27, 11/2015 Viessmann Manufacturing Checking The Flue Gas Temperature Sensor If it is suspected the flue gas sensor is not operating correctly it can be checked with a temperature meter and an ohm meter. Take the temperature at the probe tip and compare it to the corresponding ohm reading on the chart. Flue Vent Limit sensor Safety Setting 230 F / 110 C

Foil 28, 11/2015 Viessmann Manufacturing Checking The Boiler Water Temperature Sensor (AHL) The boiler water temperature sensor can be checked in the same manner as the flue gas temperature sensor. Make sure you use the correct chart for each sensor, as some sensors in the boiler have different ranges. AHL sensor

Foil 29, 11/2015 Viessmann Manufacturing Checking The Gas Pressure Check the inlet gas pressure at high fire before doing the combustion analysis. Running pressures should be between: 4 wc and 14 wc for Natural Gas. 10 wc and 14 wc for LPGas.

Foil 30, 11/2015 Viessmann Manufacturing Testing The Products Of Combustion A combustion test should be performed any time the burner has been serviced and when the boiler is commissioned. Insert the test probe of the combustion analyzer into the test port in the boiler s flue gas collar. Perform a Relay Test Products of Combustion Port

Foil 31, 11/2015 Viessmann Manufacturing Performing A Combustion Test Turn the heating dial to the right all the way to the reset position, wait for SERV to be displayed on the screen then turn the dial back into the control range. Wherever the dial position is set will be the boilers current firing rate during the test. Check combustion in High and Low fire positions. blinking visible

Foil 32, 11/2015 Viessmann Manufacturing Burner Adjustments Adjustment to the fuel air mixture can be done at the adjustment points on the burner. If the CO 2 is within the ranges published in the manual no adjustment is required.

Foil 33, 11/2015 Viessmann Manufacturing Testing The Products Of Combustion When the boiler is vented with a coaxial venting system the integrity of the flue gas pipe cannot be visually inspected. Using a combustion analyzer into the combustion air test port will test for products of combustion in the fresh air that might be present if the vent pipe gaskets are compromised. Testing for products of combustion in the combustion air stream: Insert combustion analyzer into Combustion Air Port. With the burner operating, readings should be less than 0.2% CO 2, and greater than 20.6% O 2 If readings are outside these limits check the venting system for leaks. Combustion Air Port Products of Combustion Port

Foil 34, 11/2015 Viessmann Manufacturing Power Pump Module Power Pump Module

Foil 35, 11/2015 Viessmann Manufacturing Main Control Fuse Located inside the Power Pump Module 6.3A main Fuse Power Pump Module

Foil 36, 11/2015 Viessmann Manufacturing Main control Interface Note: Power switch turns the power off to the Control Module not the Power Pump Module. Programming & CombiPLUS DHW set point selector dial Programming & Heating set point adjustment Control power switch Pressure Gauge LCD window

Foil 37, 11/2015 Viessmann Manufacturing LCD Display Call for DHW Call for heat Temperature F, Fault #, Program code value, display Fault Service mode Burner on Modulation Eco / Comfort mode indicators (CombiPLUS only)

Foil 38, 11/2015 Viessmann Manufacturing Faults And Fault Reset Faults are displayed on the main LCD window The fault code chart in the Service manual will provide clarification of the faults Fault Indicator Fault Code

Foil 39, 11/2015 Viessmann Manufacturing Fault Code Checker There is now a fault code checker on the Viessmann Canada website under the Pro Login tab. http://www.viessmann.ca This is also included in the VitoApp available through the Android Play Store or the Apple Store. The App if free on either system. Link to the Service Manual

Foil 40, 11/2015 Viessmann Manufacturing Call For Heat But Burner Won t Fire And No Fault Code Is Displayed The DHW or Heating Icon is displayed but the burner is not operating. This is typically a sign of no, or low water flow. There is no alarm for this condition. Check the pump, flow switch, closed valves, switch orientation etc. When flow is adequate the boiler will operate. Call for heat or Call for DHW Burner not on Flow Switch

Boiler Coding Quick Reference Chart Service, Web Based Training Foil 41, 11/2015 Viessmann Manufacturing

Boiler Coding Quick Reference Chart Service, Web Based Training Foil 42, 11/2015 Viessmann Manufacturing

Foil 43, 11/2015 Viessmann Manufacturing For More Information 1. Contact your local Viessmann Sales Representative 2. Download literature and technical manuals by going to the ProLogin section of the Viessmann website: http://www.viessmann.ca/en/residential/downloads/ma nuals.html 3. Get more training at one of our in-depth 1 or 2-day Academy seminars. Go to the Academy section of the Viessmann website for the full schedule of all our inhouse training. 4. Recordings of this and other Viessmann Academy Webinars are available on-line at our website: http://www.viessmann.ca/en/company/academy/webinar s.html

- Service and Maintenance