Packaged Marine Design Thermal Fluid (Hot Oil) Heaters

Similar documents
Thermal Fluid Heaters

Helical Coil Heaters. Hot Oil Heaters Booster Heaters. CEI Enterprises

Williams & Davis Boilers

FUEL-FIRED VERTICAL TUBELESS BOILERS

Industrial Applications

Fuel-Fired Vertical Tubeless Boilers

MOHICAN. MOHICAN 4-Pass Water Boiler, HP, PSI Section

12711 TOWNEPARK WAY / LOUISVILLE, KY / / FAX

Concrete Applications

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

Williams & Davis Boilers

There are two devices used together for heating crude oil in petroleum refinery as in figure (1), and these devices are:

HEATEC PRODUCTS AND SERVICES FOR THE FOOD INDUSTRY

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Burner Comparisons. Typical Competitor s Burner

FXLF-9. High Efficiency Water Heaters and Boilers

1. Know your process. The following guidelines will help you navigate what can be a challenging and time consuming task.

HEATEC PRODUCTS AND SERVICES THAT EXCEED YOUR EXPECTATIONS

High Efficiency Commercial Gas Water Heaters

UTICA BOILER. SSV Submittal. Project Name: Project Location: Contractor:

SECTION HEATING BOILERS

SAMPLE SPECIFICATIONS

Condensing Hydronic Boilers 2,000,000-6,000,000 BTU/HR

Fuel-Fired Vertical Tubeless Boilers. Classic, Edge, Tribute and VMP Models From 4 to 150 BHP (138-5,021 lbs/hr)

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

Oil and Gas Heaters ZICOM EQUIPMENT PTE LTD

University of Houston Master Construction Specifications Insert Project Name SECTION DOMESTIC WATER HEATERS PART 1 - GENERAL

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

SIOUX WATER HEATERS. Hot Water for Cold Weather Concrete Production. Better Concrete Higher Profits. Sioux Water Heaters and Steam Generators

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

DIVISION FIRE-TUBE STAINLESS STEEL HEATING BOILERS

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

DOM-5. Domestic Hot Water Heaters & Boilers

PACKAGED COMMERCIAL WATERTUBE BOILERS

Originators of the Flexible Water Tube design

HEATEC TEC-NOTE. Operation and maintenance Heatec thermal fl uid heaters industrial series IMPOPRTANT NOTICE! CONTENTS. Publication No.

SUBMITTAL SCHEDULE & DATA

TURBOPOWER. Non-Condensing Gas, Oil or Combination Gas/Oil Storage Water Heater. 199 to 4000 MBH 150 to 4500 Gallons Tanks 25-year Warranty. PVI.

Columbia Boiler Company

DIVISION FINNED WATER-TUBE BOILERS

FXLF-4. High Efficiency Water Heaters and Boilers

The pictures shown in this folder are but a few samples that illustrate the variety of locations and ways our products are used.

ClearFire. Startup Guide. Model CFH. Horizontal Steam Boiler

FINNED WATER-TUBE POOL HEATERS

DIVISION FINNED WATER-TUBE BOILERS

Proven Heritage RTS STANDARD EQUIPMENT. (413) FAX: (413) You can rely on Smith Cast Iron

Domestic Hot Water Heaters and Boilers FTIIIC-6

DIVISION FINNED WATER-TUBE WATER HEATERS

FTIIIC-10. Domestic Hot Water Heaters and Boilers

Bryan Water-Pak Indirect Systems 360,000 BTU to 4,500,000 BTU Inputs 199 to 3,533 Gallons Storage Capacity

HORIZONTAL FIRE TUBE BOILERS Piping (HVAC) Pumping Equipment (HVAC).

Silhouette. Feedwater Heater. Boiler Feedwater

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

DIVISION FINNED WATER-TUBE BOILERS

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

MODEL M5M. High-Efficiency Packaged Watertube Boiler MMBTU

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

WATER-TUBE POOL HEATERS

FINNED WATER-TUBE POOL HEATERS

DIVISION FINNED WATER-TUBE WATER HEATERS

DIRECTIVE NO: D-B

WATER-TUBE POOL HEATERS

HHA Bellerive Apartments 7225 Bellerive Houston, Texas J. Allen Management Managing Agent

Multiple Heater Controller TempTracker Mod+, up to 16 heaters

High Efficiency Commercial Gas Water Heaters

Solution builder. in energy management.

Revitalize Building Mechanical Systems (4619)

SERIES 19A. mith PRESSURIZED WET BASE

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

Phantom-X 399C/500C. Residential High Efficiency Gas Boilers PHNTM399C, PHNTM500C Submittal Sheet. Wholesaler Job Name Mechanical Contractor

SIOUX Water Heaters SIOUX WATER HEATERS. Hybrid Water Heater PWP Water Heater M-1

CCLEARFIRE CONDENSING FIRETUBE BOILER DESIGNED FOR MAXIMUM HYDRONIC SYSTEM EFFICIENCY 500 TO 3,300 MBTU

Rental Boiler Specifications (Nebraska Boiler)

THE PRESSURIZED CONDENSATE RECOVERY SYSTEM:

ES2 Boiler 85% AFUE. Limited Lifetime Warranty! boiler control. option. option card. control system GREATER ENERGY SAVINGS. Cast Iron Water Boiler

CONDENSING, MODULATING, HOT WATER SUPPLY, POOL, AND HYDRONIC HEATING BOILERS

BASCO TYPE ES EXTENDED SURFACE PLATE FIN HEAT EXCHANGERS. ...world leaders in heat transfer technology

.2 Section Waste Management and Disposal..4 Section Vibration Isolation and Seismic Control Measures.

DESCRIPTION, CAPACITIES, SPECIFICATIONS, APPLICATIONS

HHA Lyerly Apartments 75 Lyerly Houston, Texas J. Allen Management Managing Agent

COMMERCIAL CONDENSING GAS WATER HEATER GALLONS, 55,000 BTU/HR 94% THERMAL EFFICIENCY

Engineer: Project Name: Project Location: Contractor:

Boiler Basics. Design and operation

SECTION FLUID HEATER. 1.2 RELATED SECTIONS A. Division 16 - Equipment Wiring Systems: Electrical characteristics and wiring connections.

Models 1005, 1505, Up to 99% thermal efficiency! Can be vented with PVC pipe Use Option D-32

Automatic Circulating Water Heaters

TWINTEMP JR. HYDRONIC SYSTEM 2/2013

CHAPTER 3 BASIC STEAM CYCLE

SECTION AIR COILS

Originators of the Flexible Water Tube design

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

ONQUEST. Featuring... Condensing Water Heater. Requires no tank linings or heat exchanger linings. Requires no anodes of any type. 10- year warranty.

Fuel-Fired Vertical Tubeless Boilers. Classic, Edge, Tribute and VMP Models From 4 to 150 BHP (138-5,021 lbs/hr)

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

HIGH-EFFICIENCY COMMERCIAL GAS WATER HEATER 3-Year Tank Warranty 1-Year Parts Warranty

Originators of the Flexible Water Tube design

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

Engineer: Project Name: Project Location: Contractor:

Transcription:

PACKAGED MARINE THERMAL FLUID (HOT OIL) HEATERS Packaged Marine Design Thermal Fluid (Hot Oil) Heaters For Heating Asphalt Barges, Tankers, And Any Other Application Requiring Dependable Heating 13 Models Starting At 500,000 BTU/HR Topping Out At 20,000,000 BTU/HR Volcanic Heaters are available with single or double wound helical coils pending requirements Volcanic Heater, Inc.

Volcanic marine type thermal fluid heaters operate within a closed loop The end mounted burner fires down the inside of the helical coil unit, heating the thermal fluid, which is pumped through the coils and travels throughout the system back to the expansion tank. These 2 pass gas flow systems operate with precise temperature control, and can reach temperatures up to 399 o with class II barge piping or higher with class I barge piping while operating at minimal low pressure. Heat transfer takes place by convection and radiation on the inside of the coil surface -- convection on the outside. The Volcanic heater, using its original Hopkins design is a long proven rugged work horse suited for on-deck usage. Volcanic marine heaters are complete packaged heaters with these great features Low maintenance. Unattended operation. Automatic running and safety controls. No rust, no corrosion, no freezing with hot oil systems. Built to customer specs. Control panel and expansion tank can be mounted in "right hand or left hand" position. No pressures associated with a thermal fluid closed loop system. Volcanic heaters come with a one year warranty. The burner and control panel are protected by a waterproof housing. Control panel and expansion tank can mount left or right. Several Volcanic Heaters can be seen "on-deck", heating asphalt cargo on this inland waterways barge

Volcanic - a sound name in Marine Heaters riding the waterways for years A Volcanic marine heater is no ordinary thermal fluid heater. It's a durable long lasting work horse unlike most "land based" designed heaters. And, Volcanic still uses the original Hopkins design helical coil concept. Volcanic heaters have been working the Canadian and American waterways from coast to coast for years. These hot oil helical coil design heaters are designed and built, in fact, overbuilt, for years of hard work on asphalt barges, tank farms, anywhere heat is needed to deliver the goods. Volcanic heaters are used with unattend operation.

System Pressure (P.S.I.G.) 1400 1000 Saturated Steam/Water Thermal Fluid 1500 500 400 300 200 100 0 0 C 50 C 100 C 150 C 200 C 250 C 300 C 350 C 0 F 122 F 212 F 302 F 392 F 482 F 572 F 650 F Operating components of the Volcanic marine heater 1 2 Miles of barge heating piping carries hot oil to users with minimal to no pressure With steam* at 338 o F (170 o C), a pressure of 100 PSIG (7 bars) is required and at 572 o F (300 o C) the pressure rises to nearly 1500 PSIG (105 bars). With thermal fluids, these temperatures are achieved *Saturated steam or pressurized water 5 6 7 at low pressures and system pressure drop for pump circulation of the fluid is the only governing factor. 9 10 8 11 3 1 The burner and electrical control panel are protected by a waterproof housing for on deck usage. Control panel meets NEC and UL Codes. 2 High combustion efficiency is obtained by pressure atomization of fuel oil and high pressure air. An electric pre-heater heats the residual fuel oils for proper atomization. 3 Electrical panel meets all required codes and can be mounted on either side of the heater package. 4 Optional controls provide full modulation with low fire start and up to 6:1 turn down ratio. Burners meet USCG requirements and ABS on request. 5 Extra heavy steel cylindrical shell surrounds the helical single 4 12 or double wound coil made from Schedule 40/80 seamless pipe. Spacers separate the coil and shell. 6 The shell is covered with layers of ceramic fiber blanket insulation. A rigidizer is sprayed on the surface to protect against velocity of exiting gases. 7 Helical Coil - single or double wound designed by Volcanic. 8 Access door allows for inspection and maintenance tasks. 9 Observation port allows for checking flame pattern and flue combustion conditions. 10 Separation/surge tank velocity of thermal fluid returning from the system is decreased to allow any steam or air in the system to escape into the expansion tank. 13 11 Expansion Tank - as the system is brought up to operating temperature, heated thermal liquid expands into the expansion tank from the separation tank. Thermal liquids expand approximately 4% by volume for each 100 o F temperature increase. When the system is shut down and the liquid cools, liquid is withdrawn from the expansion tank to maintain a filled circulating loop. 12 Cold Seal Tank - The thermal liquid system is vented to the atmosphere through this tank to expel air and any steam during system start up. 13 Circulating Pump - A centrifugal pump is used to supply thermal liquid for the entire system. Pumps are selected to meet flow and pressure drop requirements of the system. Pumps are jacketed for water cooling when thermal liquid in the pump is above 350 o F when required.

Features of the standard safety and limit controls Flame Program & Safety Control - The flame program control provides for ignition and flame failure protection for automatically ignited burners. With limit, operating controls and interlocking devices, the control automatically programs the operation of burnerblower motor, ignition, fuel valves and modulator. Low Flow Cut Out - Protects the heater and the fluid. This differential pressure switch measures pressure drop through the heater coil, indicating flow. Low flow will shut down the burner. (Manual reset). Low Level Control - This float cage type switch is usually attached to the expansion/ surge tank. It will shut the burner down on low liquid level and turn off the red limit light, and will restart the burner when the proper level has been returned and reset. High Temperature Cut Out - The sensing element is located in the heater fluid line. The set point which is set by factory technician to customer and USCG specifications, should never be above the maximum temperature permissible for the fluid used in the system. In case the set point is reached, the instrument will shut the burner down. Low Fuel Oil Pressure Cut Out - Control shuts off the burner if the pressure in the fuel oil supply line drops below the minimum required for proper atomization. Alarm circuit and Signal Light - The burner wiring is arranged in such a manner as to ring an alarm in case of flame failure. Manual resetting is required. In case of "flame failure" the button on the flame program control must be pushed. All other limit safety switches will only energize the red limit light if closed. Once the cause of stoppage is eliminated, the burner will restart after resetting. Low Fire Interlock Switch - This switch is part of the modutrol motor, and serves as a safety interlock which will prevent the burner from starting unless its components are set to provide "low fire" only. This provides for safe ignition. Volcanic Marine Heaters feature convenient lifting rings for ease and safe positioning on deck Volcanic personnel work with the customer, creating layout, piping, and heat requirements to produce a totally efficient system. When a shipyard sets out to build a vessel, a barge, Volcanic engineering and system designers will work with the customer to get the job done. Sizing of the heater, the helical coil, the pumping, the piping package, taking into consideration the vessel's holding size - everything is calculated. And when it's all sized right and up and running, we at Volcanic know it's a precise and highly efficient system that will perform without flaws for many years to come. Volcanic's Packaged System Skid mounted heaters are complete units containing all operating controls and instruments. Installatin time is minimized due to quick connections for power leads, fuel lines, stack, and thermal fluid piping lines. Volcanic service engineers complete on site start up and go through maintenance procedures with the customer.

Specifications - Volcanic Thermal Fluid Heater Model 50 75 100 200 300 400 600 800 1000 1200 1500 1800 2000 Output Cap. Million BTU/HR. 0.50 0.75 1.0 2.0 3.0 4.0 6.0 8.0 10.0 12.0 15.0 18.0 20.0 Heat Trans. Sur., Sq. Ft. *1 55 85 111 220 335 445 670 890 1110 1330 1660 2000 2220 Thermal Liq. Fow, GPM *2 50 60 75 150 225 300 425 600 725 900 1100 1350 1500 Coil Pressure Drop, PSI 8 17 8 18 18 17 23 16 15 25 11 20 10 Circulating Pump, HP *3 5.0 7.5 7.5 10.0 15.0 20.0 25.0 30.0 40.0 50.0 60.0 75.0 100.0 Burner Combustion Air, cfm 114 170 228 456 684 912 1368 1824 2280 2740 3420 4100 4560 Blower Motor, HP 1/3 0.5 0.5 1.0 2.0 3.0 5.0 7.5 15.0 20.0 25.0 30.0 40.0 *1 Provides a heat flux of 9,000 BTU/Hr. sq. ft. *2 Based on an oil temperature increase of approximately 55 o F through the heater *3 Based on centrifugal pump @ 150 ft. TDH. *4 For fuel consumption rate, consult factory. Dimensions - Volcanic Thermal Fluid Heater Model 50 75 100 200 300 400 600 800 1000 1200 1500 1800 2000 (A) Overall Height 53 53 53 64 72 78 89 89 104 104 112 119 119 (B) Shell Diameter 40 40 40 51 59 65 74 74 86 86 94 101 101 (C) Stack Diameter 8 10 12 15 18 22 26 30 33 36 40 43 45 (D) Pump Extension 38.5 38.5 38.5 44 51 54 62 62 71 71 78 82 82 (E) Base Width 54 54 54 65 75 82 94 94 108 108 118 124 124 (F) Overall Width 58 58 58 69 83 89 104 104 122 122 136 143 143 (G) Outlet Height 29 29 29 34.5 38.5 41.5 48 48 57 57 61 64.5 64.5 (H) Shell Height 49 49 49 60 68 74 85 85 100 100 108 114 115 (I) Shell Length 60 72 86 122 147 171 218 278 286 334 356 385 426 (J) Burner Length 27 27 27 30 37 37 44 44 54 54 74 77 77 (K) Base Length 46 54 66 98 123 143 178 248 253 298 320 349 390 (L) Overall Length 97 109 123 162 194 218 272 332 350 398 440 472 513 (M) Inlet Height 46 46 46 56 64 69 80 80 94 94 101 106 106 Coil Diameter 30 30 30 40 48 52 60 60 72 72 84 97 97 Pipe Size of Coil 1.5 1.5 2.0 2.5 3.0 3.5 4.0 5.0 4.0D 4.0D 5.0D 5.0D 5.0T Inlet-Outlet Size 2.0 2.0 2.0 3.0 3.0 4.0 4.0 6.0 6.0 8.0 8.0 10.0 10.0 Thermal Liquid Volume/Gal. 35 43 59 114 224 318 568 881 965 1,137 1,767 2,064 2,294 Weight Pounds 3,960 4,420 4,920 8,500 11,315 14,700 20,365 26,360 33,000 38,170 46,500 51,950 54,425 Expansion Tank Volume/Gal. 43 56 71 140 246 293 602 786 1,167 1,379 2,006 2,179 2,425 Volcanic Marine Design Heaters are built to ASME Code, Section I C I A B E F D H J K L G M VMH 1M 1z FLP11/03 Printed in USA Volcanic Heater, Inc. 201 West Hartzell St., Box 2540 Alliance, Ohio 44601 Call 330 823. 0770 Fax 330 823. 0772 www.volcanic-heater.com 8302 Reservoir Avenue Houston, Texas 77049 Call 281 860. 0063 Fax 281 860. 0096