Passive infrared ceiling sensor

Similar documents
Green Switch HD/HC/HS L/N/NT4658N - AM5658. Technical sheets - Automation MY HOME 1. Front view 8

Detector switch - Dual Tech SCS

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

SCS motion sensors Surface/wall mounting - PIR

Sensors SR Programming manual

Transponder reader TECHNICAL SHEET (White) (Magnesium)

Tri-level Control Sensor

UP 258E11 OPTISENS OFFICE

Installation Guide. Ceiling PIR Detector (311) Features and Connections

NEW. lighting management - stand alone detectors, power packs. Passage detection - Infrared technology. Detectors with power packs

Sensors and Detectors

PSC-BL-I-FM-DC0(-BLE) Bi-level Dimming PIR Sensor

Ceiling PIR HS presence detector. Product Guide. Overview. Features

TER Active Room Temperature Sensor (Controller),

Product and Applications Description

DALI MSensor 02 Multi-sensor for DALI system

Data sheet. Function description. Benefits

Motion detector themova P360 KNX UP WH themova P360 KNX UP GR

Tebis application software

IP65 High Bay Dual Sense Sensor

11,9. Ordering data. Max. cable length sensor head 1 basicdim ILD lx 150 lx m 1

User Manual Doc.Ref : EVO-KNX-UM. EVO-KNX Paradox KNX Interface ELAUSYS EVO-KNX. KNX Interface for Paradox alarm system. User Manual.

IP65 High Bay Dual Sense Sensor

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors

EBDSPIR-PRM-LV Product Guide

Mounting bezel Retaining spring. Detects movement within the detection range, allowing load control in response to changes in room occupancy.

Operating instructions

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor

DALI MSensor 02 Multi-sensor for DALI system

OPERATING INSTRUCTIONS

1. Product characteristics 4 2. Safety 5 3. Proper use 5 4. Operation 6

luxcontrol lighting control system basicdim basicdim ILD Compact control module with ambient light sensor and motion sensor

THE EVOLUTION OF CONTROL APP & CLOUD PORTAL

Devices for Special Applications

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Function description. Channel A light. Motion detector

Description of the application programme for KNX occupancy detectors version 3.1

Controller - 4 x 1-10 V outputs - BUS/KNX

Detector switch - Dual Tech

Presence detector Komfort attachment Installation Instructions

FR-A180 FR-A360. Occupancy detector. Use

11,1 30. Ordering data

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

Description FEATURES. l Innovative dual mount system requires only one sensor for either flush or surface mount applications

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

2. Safety. 4. Function

PRESENCE DETECTOR. PD-C360i/8 mini KNX PD-C360i/12 mini KNX / 13 7 REMOTE CONTROL PRESENCE DETECTOR

Knürr RMS Compact II. Knürr RMS Compact II 2.81

PPAD-C-230V. Ceiling PIR presence/absence detector. Product Guide. Overview. Features

Product and functional description

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC

SWITCHLITE MRE SLD MAN SWITCHLITE MRE SLD IP55

B.E.G. LUXOMAT. Find the right detector.

3. Intended use. 4. Function. 1. Product characteristics. 2. Safety. Functional description. Channel A light. Motion detector

Connections, displays and operating elements C D E G H. Installing the control unit

Touch Screen Thermostat. MTSC/SUPER/CO2, MTSC24/SUPER/CO2 Series. MTS/SUPER/CO2, MTS24/SUPER/CO2 Series. Owner s manual and technician settings

, ,

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features

Applications: 27. NETIChome mobile ios 28. NETIChome mobile Android. NETIChome basic elements

Eco-sensors - PIR. Catalogue number(s): / / Use. 1. Use Technical characteristics (continued)

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

Movement-based energy control

Premium Version Tri-level Dimming Control

S INTRUSION&FIRE ALARM AND ACCESS CONTROL PANEL

Dew point set DS 400

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

PIR OnOff Page 2-3 PIR & Radar MinMaxOff Page 3-8. Sensor Manual LedgeCircle

LPCMPIRM65 & LPCMPIRDSI65

EBDSPIR-PRM-2CH, EBDSPIR-PRM-2CH-NC

User Manual Doc.Ref : JA-KNX-UM. JA-KNX Jablotron KNX Interface ELAUSYS JA-KNX. KNX Interface for Jablotron alarm system.

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

User Manual 120/240/300 Outdoor Motion Detector

B.E.G. LUXOMAT KNX-OCCUPANCY DETECTOR

D45 System. Colour 7 handsfree indoor handset. Front view

1. Basic safety information 3 2. Proper use 3

Product Guide. Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Integrated SensorDIM LED Driver Daylight Monitoring Version

Monitoring Solutions

System 2000 System 2000 presence detector Comfort top unit. 1 Safety instructions. 2 Device components

LPC3BSP65 & LPC3BDP65

Light & Motion. Sample applications 259. Ceiling sensors. Wall sensors. Outdoor sensors. Motion. Light &

LINKABLE UNDERCABINET

Instructions manual. By-alarm. By-alarm Manager software

Rev KNX Technical Reference Manual Busch Präsenz tech 6131/ /11-500

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

LED HIGH BAY LINEAR ECO SERIES

FIRERAY 5000 range USER GUIDE

Movement controller comfort, Flush-mounted (Up) xx, xx

Laser Distance Sensor Type M Analog-Output

Technical Application Guide

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

SmartAlarm Annunciator

luxcontrol lighting control system basicdim basicdim ILD 5DPI 14f Compact control module with ambient light sensor and motion sensor

1 Safety instructions. 2 Device components. Presence detector. Operating instructions

AddressPro Digital Dimming Technical Product Information

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

MPAD-C 12-24V. Ceiling microwave presence/absence detector 12-24V AC/DC. Product Guide. Overview. Features

MWS3 Ceiling Mount Microwave Occupancy Detector

Transcription:

Passive infrared ceiling sensor 88 Description Control and command device, powered by the SCS BUS, with two different sensors, the combination of which enables managing the light level inside the room, taking into account both the presence of people, and the level of natural light, therefore ensuring efficient energy savings and better user comfort. The device has an IP 0 protection index, and is intended for ceiling mounted installation. The sensor is fitted with: - BUS wiring connector; - PIR movement sensor; - light sensor; - internal microcontroller; - two-colour LED; - multifunction key; - configurator socket. PIR movement sensor: it detects the presence of people inside the room. It s used inside rooms with free view, without obstacles, for the detection of people. Light sensor: it detects the light level inside the room, switching the load ON or OFF based on whether the light threshold set on the sensor (adjustable by the user) is lower/higher than the value detected. The light sensor has priority on the movement sensor: if the PIR sensor detects a presence, but natural light is sufficient, no load management signal is sent by the device. In order to avoid continuous switching ON and OFF, a tolerance on the threshold values must be set. Device with cover Device without cover 5 6 The sensor may be installed in a MY HOME system and can be configured both physically and virtually, or as a component of the Lighting Management system using specific configuration procedures (Plug&Go, Push&Learn, Project&Download). Technical data Power supply: 7 Vdc Absorption: 0 ma Operation: ON/OFF, dimmer Operating temperature: (-5) (+5) C Sensor type: PIR Protection index: IP0 Sensitivity: 000 lux Time delay: 0 s 55 h Coverage of the PIR sensor at.5 m: Ø 6m(8m ) Covering angle: 90/60 Maximum installation height: m Type of connection: screw clamps Standards, Certifications, Marks EN 508 Legend. LED indicator: - fixed green = BUS detected - orange flashing once = movement detected. - orange-green flashing quickly = no configuration or wrong configuration. - orange-green flashing for second = configuration being performed - red flashing quickly = acquiring the Set Point - red-green flashing quickly = sensor calibration being performed. Light sensor. Infrared PIR movement sensor. Multifunction key: - Short pressure to select the device when using the virtual configuration. - Pressure for seconds, for the acquisition of the Set Point when working in Stand Alone Mode. - Two short pressures to enter the Push&Learn procedure during operation with the Lighting Management system. - A short pressure, followed by an extended pressure of 0 sec. to reset the sensor. 5. BUS connection screw clamps 6. Configurator socket (attention, it must only be used in MY HOME systems with physical configuration)

TECHNICAL SHEETS 88 Dimensional data Covering range for item 88 75 mm The movement sensor is supplied with a lens with actual covering range area as shown in the figure below..5 m 8 m 0 mm m 5 mm 0 mm Adjustable sensitivity level Low Medium High Max. A (m) Ø (m) S (m ) Ø (m) S (m ) Ø (m) S (m ) Ø (m) S (m ).5 7 5 0 6 8 7 6 8 7 8 7 5 0 7 8 8 50 Legend: A = installation height (m) Ø = diameter (m) S = surface (m ) MY HOME configuration When installed in a MY HOME system, the device may be configured in two ways: - PHYSICAL CONFIGURATION, by connecting the physical configurators to their sockets. - VIRTUAL CONFIGURATION, by connecting the system to the PC or the web server. The Virtual configurator software must be installed on the PC. Physical configuration The features of the device are defined by 6 configurator sockets, and their functions depend on the operating mode: Room: A = 9 Light point: PL = 9 Mode: M = 0 8 PIR movement sensor sensitivity: S =0 Load ON time: T = 0 9 WARNING: Addresses A = 0 and PL = 0 do not exist

88 Possible function The device controls the load with the address indicated in A and PL. When a movement is detected, if the light level is lower than the set level, the device switches the assigned load on, and keeps it on until the time set with the configurator connected to T expires (Auto Mode). The PIR movement sensor sensitivity is set with the configurator connected to S. For correct operation, the sensor lighting set point must be set (see procedure). If the user switches the light OFF manually with a control device, the movement sensor is disabled until a movement is detected, for a time set in T. In this mode the sensor operates as a pure twilight switch, the movement sensor is disabled. When the light level falls below the set threshold, the device switches the load on, and switches it OFF when the light level exceeds the threshold again (Auto Mode). Configure A = -9 and PL = -9. GEN, ROOM and GR configurators cannot be connected. In this mode configurators S and T are not connected. In this mode the device does not directly manage a load, but sends to the scenario programmer the notification of a movement and the lighting value. In this case the device address will be connected to A and PL, which must be unique within the system. Therefore, the GEN, ROOM and GR configurators cannot be connected. In this mode the S and T configurators are not connected, as these parameters are managed directly by the scenario programmer. In this mode the device directly manages the load, maintaining a constant light level inside the room (this mode is only valid if the sensor manages a dimmer); when a movement is detected the device switches the light on and keeps it on based on the presence of people and the desired light level (Auto Mode). When a movement is detected, if the light level is lower than the set level, the device switches the assigned load on, and keeps it on until the time set with the configurator connected to T expires. During its operation the sensor maintains a constant light level based on the configurator connected to D; for example, when the outside light level increases, the device decreases the brightness of the load driven. For correct operation, the sensor lighting set point must be set (see procedure). It is possible to change the threshold set using a control that changes the brightness: this new value is set as a new sensor set-point until the next switching ON. In this mode the device operate as a pure twilight switch and manages the load directly, maintaining a constant light level inside the room, disabling the presence sensor (this mode is only valid if the sensor manages a dimmer). The switching ON of the load is manual, while the switching OFF is managed automatically by the sensor based on the desired light level (Eco Mode). When the light is OFF the sensor therefore does not switch the load on, but waits for the user to do so using a manual control. During its operation the sensor maintains a constant light level based on the configurator connected to D; for example, when the natural light level increases, the device decreases the brightness of the load driven. Once the load has been switched OFF, if the natural light level decreases the sensor will no longer switch the load on, but will wait for the user to do so manually. For correct operation, the sensor lighting set point must be set (see procedure). It is possible to change the threshold set using a control that changes the brightness: this new value is set as a new sensor set-point until the next switching ON. Configurator in M The device controls the load with the address indicated in A and PL (SEE FUNCTION WITH M=0). The switching ON of the load is manual and the device keeps the load on based on the presence of people and the desired light level (Eco Mode). 5 In this mode the device maintains a constant light level inside the room (SEE FUNCTION WITH M=). The switching ON of the load is manual and the device keeps the load on based on the presence of people and the desired light level (Eco Mode). 6 In this mode the sensor operates as a pure twilight switch, the movement sensor is disabled (SEE FUNCTION WITH M=). The switching ON of the load is manual and the device keeps the load on based on desired light level (Eco Mode). 7 0 In this mode the device operates as a pure twilight switch and directly manages a load, maintaining a constant light level inside the room, disabling the movement sensor (SEE FUNCTION WITH M=). When the light level falls below the set threshold, the device switches the load on, and switches it OFF when the light level exceeds the threshold again (Auto Mode). 8 WARNING: when managing scenarios using the information from the sensor, using the scenario programmer, the sensor must be configured exclusively in M= mode.

TECHNICAL SHEETS 88 ) Table of the active load times based on the configurator connected to T: Configurator in T Active load time in min. No configurator 5 0 sec. 5 5 0 6 5 7 0 8 0 9 0 ) Sensitivity table for the PIR movement sensor based on the configurator connected to S: Configurator in S No configurator Sensitivity Low Medium High Very high Procedure for the acquisition of the sensor lighting set-point: - Press the pushbutton for two seconds. - The LED will start flashing red quickly. - Move away from under the sensor, so that it can perform a correct measurement - After about 0 sec. the LED stops flashing and the sensor finishes the acquisition. NOTE: it is important that the set-point is reacquired every time the sensor position is changed, and every time that what is under the sensor changes. Virtual configuration Using the Virtual configurator software it is possible to perform all the functions listed below: - local lighting/movement detector - local lighting sensor - local movement sensor - central lighting detector - central lighting sensor - central movement sensor Lighting Management configuration When installed in a Lighting Management system, the device can be configured in the following ways: - Plug&Go (see the dedicated technical guide) - Push&Learn - Project&Download, Using the Virtual configurator software it is possible to perform all the functions listed below: - local lighting/movement detector - local lighting sensor - local movement sensor - central lighting detector - central lighting sensor - central movement sensor For more information on the functions see the glossary before the Technical sheets chapter. Installation mode The sensor must never be installed near heat sources or near the splitter of the cooling system.

88 5