Transition 500-PIV Series Multi-Technology Readers Installation Manual

Similar documents
Installation Manual. Wiegand Interface Unit Four-State (WIU-4) North America T F Asia T F

Installation Manual. Wiegand Interface Unit Two-State (WIU-2) North America T F Asia T F

RMS/RPX Reader. User Manual

TruVision Bullet IR Camera Pocket Guide

TruVision Bullet IR Camera Pocket Guide

KM300 Carbon Monoxide Detection System Installation Manual

R Series Remote Annunciators and Expander Installation and Operation Guide

Model SWH-4000 Multi-Technology Mullion 125 KHz and MHz (Flex) Reader Installation Guide. Version A0 Part Number UM-104 September 2005

Model SWH-3000 Proximity Multi-Frequency 125KHz & 13.56MHz (Fixed) Reader Installation Guide. Version A0 Part Number UM-102 September 2005

TruVision IR Turret Camera TVT-2202/TVT-4202 Installation Guide

FTP-1000 Touchpad/Display Installation Manual

ATS1235 Advanced Wireless DGP on 868 MHz AM Installation Sheet

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions

IFS SFP Tranceivers User Manual

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions

VT1101M VT1102M IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions

KFP-CF Series Operation Manual

IFS Fiber Module Installation & Operation Instructions

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

GE Security. Challenger V8 & V9. User Manual

Figure 1. These Installation Instructions -1- K4866 4/00 OmniProx Reader Model Series OP-10/20/30/40

IFS Fiber Module Installation & Operation

UNC100 Integra Manual

TruPortal Wireless Locks Quick Reference

ZP2 Series Operation Manual

TransitionTMSeries Readers

NetworX NX-548E Receiver Installation Instructions

Advisor Advanced User Guide

1X-F Series Installation Manual

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

FEC403EN Installation Manual

GE Security. ATS1250/ door DGP / 4-lift DGP. Installation guide

KTD-348 Crosspoint 32 Matrix Video Switcher

R-Series Remote Annunciators and Expanders Installation and Operation Guide

Installation Instructions

KT-100 Door Controller

ATS125x/1260 Four- Door/Four-Lift DGP Programming Guide

NX-181xx NetworX Voice keypad with touch buttons User Manual

IR Speed Dome. Quick Guide UD.6L0201B1357A01

C-Bus PIR Occupancy Sensor. Installation Instructions 5751L

Installation Instructions

Installation and ZONES: Operation Manual. Model: ON STI-34108

Independent Zone Control (I.Z.C.)

SIGA-CC1 Single Input Signal Module Installation Sheet

KFP-AF Series Fire Alarm Control Panel Installation Manual

safety & regulatory information

PERMACONN PM1030 Includes DI300. Installation Manual

Long Range Radio Alarm Transmitter

(EN) RevC AS610-AS630 Outdoor Siren Installation Sheet.pdf. Remark: Rev. Date: Modif. no.

METEOROLOGICAL INSTRUMENTS

Installation and Operation Manual. Model: STI TRIGGERED OUTPUT PLUG 12VDC, 75mA, 3 SEC. EMBOSSED PROGRAMMING

VS-AXESS-4DLX Installation Manual

TX3 Series TX3-CX-1. Installation Manual

All- IN- ONE PROXIMTY STAND ALONE CONTROLLER OPERATION MANUAL MODEL: HA3021 VERSION: 3.60

Q3000 Smart Home Alarm. Kit Content and Installation Guide

/9308 External Battery Chargers Installation Instructions

DS-K2600 Series. Access Controller. Quick Start Guide UD01216B-A

Q3200 Smart Home Alarm. Kit Content and Installation Guide

International ECO Door Controller Installation Guide

Installation Manual Premier Elite IXP-W

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick

Networked Access Control Panel. Installation Guide

Wireless Weather Station. Table of Contents

The system should also be capable of recording events automatically on any compatible DVR and should be able to retrieve recordings based on events.

CARD ACCESS CONTROL SYSTEM

4100U City and Relay Cards Installation Instructions

G4 Pulsed Fiber Laser

Adam Equipment. NCSA 20plus. (P.N Revision B - September 2012)

Netbiter Tank Sensor

For Android devices MYQ-G0301 MYQ-G0301C MYQ-G0301D MYQ-G0301LA

PDU Power Distribution Unit for IP-NINJAR. User s Guide Ver

WIRELESS COLOR FORECAST STATION

Oracle Communications Performance Intelligence Center

WS-9117U-IT Wireless 915 MHz Temperature Station. Instruction Manual

Challenger V8 & V9 User Manual

INSTRUCTION MANUAL Z-WAVE DIMMER 12387

Architectural and Engineering Specification for a. Flash / Flare

Installation Guide & User Manual

Color Forecast Station. Table of Contents

1134 Wireless Wiegand Module INSTALLATION AND PROGRAMMING GUIDE

Ambient Weather WS-0211 Wireless Wendy the Weather Wizard User Manual

For ios devices MYQ-G0301 MYQ-G0301C MYQ-G0301-D MYQ-G0301LA

1. Package content. User Manual v1.3

UBC Technical Guidelines Section Edition Access Control Page 1 of 5

3M Benchtop Air Ionizer 963E. User s Guide

Table of contents. Metra WBC-WBI RFID ISO Module - Technical Manual. Page 2

C-Bus 2 Channel Bus Coupler with Remote LED Facility Installation Instructions

ATS Control Panel Manager's manual Version 2.1, 10/2006

Clipsal is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd.

Touchpad Exit Controller Administration Guide

Installation Manual. Premier IXP-W INS538

Long Range Radio Alarm Transmitter

Controllers. Centralization of Access Control Devices Made Easy. Installer Guide

Badge Reader BR Installation Guidelines. Product Summary

Pipo Communications. Model ST-888. DTMF ANI/ENI Display Decoder

Simon XTi Quick Operation Guide

Transcription:

U.S. T 888-437-3287 F 561-998-6224 Asia T 852-2907-8108 F 852-2142-5063 Australia T 61-3-9239-1200 F 61-3-9239-1299 Transition 500-PIV Series Multi-Technology Readers Installation Manual Canada T 800-267-6317 F 613-737-5517 Europe T 32-2-725-11-20 F 32-2-721-40-47 Latin America T 561-998-6100 F 561-994-6572 utcfireandsecurity.com 2010 UTC Fire & Security. All rights reserved. GE and the GE monogram are trademarks of the General Electric Company and are under license to UTC Fire & Security, 9 Farm Springs Road, Farmington, CT 06034-4065 460660001B/11-10

Copyright Disclaimer Trademarks and patents Intended use FCC compliance 2010 UTC Fire & Security. All rights reserved. This document may not be copied in whole or in part or otherwise reproduced without prior written consent from UTC Fire & Security, except where specifically permitted under US and international copyright law. Document number: 460660001B (November 2010) The information in this document is subject to change without notice. UTC Fire & Security assumes no responsibility for inaccuracies or omissions and specifically disclaims any liabilities, losses, or risks, personal or otherwise, incurred as a consequence, directly or indirectly, of the use or application of any of the contents of this document. For the latest documentation, contact your local supplier or visit us online at utcfireandsecurity.com. This publication may contain examples of screen captures and reports used in daily operations. Examples may include fictitious names of individuals and companies. Any similarity to names and addresses of actual businesses or persons is entirely coincidental. GE and the GE monogram are trademarks of the General Electric Company and are under license to UTC Fire & Security. The Transition Series product name and logo are trademarks of UTC Fire & Security. Other trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products. Use this product only for the purpose it was designed for; refer to the data sheet and user documentation for details. For the latest product information, contact your local supplier or visit us online at utcfireandsecurity.com. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. You are cautioned that any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Certification and compliance 2002/96/EC (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.info. Manufacturer Contact information UTC Fire & Security HQ and regulatory responsibility: UTC Fire & Security, 9 Farm Springs Road, Farmington, CT 06034-4065, USA For contact information see our Web site: www.utcfireandsecurity.com

Contents Contents............................................. i Figures..............................................ii Overview.............................................1 Safety...............................................2 Electrostatic discharge (ESD)..........................2 Radio Interference..................................2 Waste Electrical and Electronic Equipment...............2 Product features.......................................3 System compatibility specifications......................4 Technical specifications................................5 Physical Dimensions...................................6 Installing the reader....................................7 Mounting the reader base...............................7 Removing the cover.................................8 Connecting the reader.................................12 Cable conductors..................................12 Wiring diagrams...................................13 Configuring the reader................................24 Setup card summary...............................25 Using configuration cards............................25 Using feature cards.................................26 Resetting the reader to a known state..................27 Testing the reader....................................28 Indicators...........................................29 GE indicators.....................................29 HID indicators.....................................29 4002 (40-bit format)................................36 5502 (55-bit format)................................38 6400 (64-bit format)................................40 GSA (75-bit format).................................42 FASC-N (200-bit format).............................44 Regulatory approvals.................................46 UL..............................................46 CE.............................................47 WEEE...........................................47 Transition 500-PIV Series Reader i

Figures Figure 1: T-500-PIV Reader dimensions... 6 Figure 2: Model T-500-PIV Gang Box Mounting... 8 Figure 3: Model T-500-PIV Direct Wall Mounting... 9 Figure 4: Model T-520/525-PIV Gang Box Mounting... 10 Figure 5: Model T-520/525-PIV Direct Wall Mounting... 11 Figure 6: Wiegand Wiring Diagram... 14 Figure 7: Wiegand 2SRP Wiring Diagram... 16 Figure 8: ACU 2X or XL with an IKE Reader... 18 Figure 9: ACU 2X or XL with RRE4... 20 Figure 10: ACU RS2/4... 22 ii Transition 500-PIV Series

Overview Transition 500-PIV Series multi-technology card readers feature simultaneous compatibility with multi-vendor credential technologies GE and HID 125 Khz Proximity, and PIV (ISO 14443A) all in one reader. Using this technology combination, system administrators can now deploy the Transition readers into existing or new facilities or systems continuing to serve existing card-carrying users while migrating to the latest in security and smart-card advancements. The Transition 500-PIV Series readers feature a rugged design and can be installed almost anywhere. Durable, weatherproof, UV-resistant materials, along with advanced electronics and circuitry, protect readers against inclement weather and exposure to sunlight. Transition Series T-520-PIV T-500-PIV T-525-PIV Transition Reader 500-PIV Series 1

Safety Electrostatic discharge (ESD) WARNING: Circuit board components are vulnerable to damage by electrostatic discharge. ESD can cause immediate or subtle damage to sensitive electronic parts. An electrostatic charge can build up on the human body and then discharge when you touch a board. A discharge can be produced when walking across a carpet and touching a board, for example. Before handling any board, make sure you dissipate your body s charge by touching ground. This discharges any static electricity build-up. Radio Interference CAUTION: This is an FCC Class A product. In a domestic environment, this product may cause radio interference, in which case, the user may be required to take adequate measures. Waste Electrical and Electronic Equipment When disposing of this product, please separate it from other waste and deliver it to the appropriate recycling center in your country, in accordance with Waste Electrical and Electronic Equipment (WEEE) directive 2002/96/EC and amendment 2003/108/EC and their respective national equivalents. For more information, visit www.recyclethis.com 2 Transition Reader 500-PIV Series

Product features The Transition Series readers combine the convenience of contactless technology with flexibility of operation. The features include: Interoperable with: GE Proximity, HID Proximity, and PIV (ISO 14443A) credentials Output modes include: PIV Wiegand Exceptional read-range performance in all types of installation environments Tri-state (red, green, yellow) LED visual indicator and audio feedback for status and activity information Hold capability for preventing unwanted multiple reads Keypad modes supports standard and customizable keypad output formats. Tamper protection Available in black Accommodates interior, exterior, metal and non-metal installation environments Lifetime warranty against defective workmanship and materials. Transition Reader 500-PIV Series 3

System compatibility specifications Access Control Systems Microcontrollers and Reader Interfaces Credential Technologies Wiegand Formats Secure Perfect with PXNplus CPU firmware Picture Perfect with PXNplus CPU firmware ACUXL version 5.76 ACURS version 5.76 Micro/5-PXNplus: 2RP, 2SRP, 8RP, and WIU-4 Micro/PXNplus-2000: WIU-4 ACUXL: RRE and IKE ACURS: Directly wired Other: Micro Reader Junction Box (MRJ), Bioscript V-Flex, Universal Wedge, and Fiber Options Transceiver GE Proximity Perfect cards: Not supported. Ultralight cards: Not supported. GE Proximity (125 khz): ProxLite, ISO ProxLite, and ProxLite keytag and patches HID Proximity (125 khz): ProxCard II, ISO ProxCard II, ProxKey II, ProxCard, and Corp 1000 (all formats) GSA PIV (13.56 MHz) GE Proximity 4002 HID Proximity: Up to 64-bit (Wiegand) Corp 1000 (Custom formats) PIV (75-bit and 200-bit) 4 Transition Reader 500-PIV Series

Technical specifications For UL compliant installation notes, refer to UL on page 46 Operating Temperature Range Relative Humidity Physical Dimensions (HWD) Power Consumption Recommended Cable Specification Cabling Distance Read Range (Distances may vary depending on environment.) -31 o F to +149 o F (-35 o C to +65 o C) 5% to 95% (non-condensing) Model T-500-PIV: 5.85" (148.6 mm) x 1.75" (44.5 mm) x 1.16" (29.5 mm) Model 520-PIV and 525-PIV: 5.85" (148.6 mm) x 4.50" (114.3 mm) x 1.24" (3.17 mm) Model T-500-PIV: Average: 95 ma @ 12 VDC Peak: 254 ma @ 12 VDC Model T-520-PIV and T-52 5-PIV: Average: 120 ma @ 12 VDC Peak: 218 ma @ 12 VDC It is recommended that 20-AWG shielded cable be used for wiring reader, DOs, and DIs. Use plenum-rated cable for applications where cable is to be run above the false (suspended) ceiling in the air circulation space. Recommended: Alpha Xtra Guard1 foil shield cable, non-plenum rated Belden series security and alarm cable (commercial applications shielded), plenum-rated Wiegand: Up to 500 ft. (152.4 m) @ 12 VDC with 20 AWG shielded cable Model T-500-PIV: GE Proximity: up to 3.5" (8.89 cm) HID Proximity: up to 3.5" (8.89 cm) PIV: up to 1" (2.54 cm) Model T-520-PIV and T-525-PIV: GE Proximity: up to 5" (15.24 cm) HID Proximity: up to 5" (15.24 cm) PIV: up to 1" (2.54 cm) Transition Reader 500-PIV Series 5

Standard Operating Modes See Configuring the reader on page 24 Agency Approvals See Regulatory approvals on page 46 Wiegand Output Mode: 75-bit FCC Class A CE UL 294 Physical Dimensions Figure 1. T-500-PIV Reader dimensions 1.750" [44.5 mm] 1.160" [29.5 mm] 5.850" [148.6 mm] Front view 4.500" [114.3 mm] Side view 1.247" [31.7 mm] [148.6 mm] 5.850" Front view Side view 6 Transition Reader 500-PIV Series

Installing the reader Follow these steps to install the Transition Series reader. These steps are explained in more detail in the following sections. The recommended sequence is: 1. Mount the reader base. See Mounting the reader base on page 7. 2. Connect the reader. See Connecting the reader on page 12. 3. Configure the reader. See Configuring the reader on page 24. 4. Test the reader. See Testing the reader on page 28. Mounting the reader base The reader is suitable for mounting directly onto standard U.S. electrical gang boxes. The reader can also be mounted directly on a hollow wall. For gang box mounting instructions: See Figure 2, Model T-500-PIV Gang Box Mounting, on page 8. For direct wall mounting instructions: See Figure 3, Model T-500-PIV Direct Wall Mounting, on page 9. To mount the T-500/520/525-PIV readers: 1. Find a suitable mounting position on the door frame or wall. 2. Drill two mounting holes a minimum of 4.125 (104.8 mm) apart on the mounting surface of the door frame or wall. Refer to Figure 3, Model T-500-PIV Direct Wall Mounting, on page 9. 3. Drill one 0.625 (15.87 mm) diameter hole in wall for the pigtail wire connection. See Cable conductors on page 12 to connect the reader to the field panel and external door equipment. For dimensions, refer to Physical Dimensions on page 6. Transition Reader 500-PIV Series 7

Figure 3, Model T-500-PIV Direct Wall Mounting, on page 9. Figure 4, Model T-520/525-PIV Gang Box Mounting, on page 10. 4. Mount the reader base to the wall using the supplied screws. 5. Install the top cover to the reader base. The base plate and top cover guides should be aligned, so the connectors seat correctly. 6. Install the top and bottom security screws provided. Conceal the security screws with the plugs provided. Removing the cover To remove the cover: 1. Remove the plugs and security screws. 2. Pull the cover off the base. Figure 2. Model T-500-PIV Gang Box Mounting 8 Transition Reader 500-PIV Series

Figure 3. Model T-500-PIV Direct Wall Mounting Transition Reader 500-PIV Series 9

Figure 4. Model T-520/525-PIV Gang Box Mounting 10 Transition Reader 500-PIV Series

Figure 5. Model T-520/525-PIV Direct Wall Mounting Transition Reader 500-PIV Series 11

Connecting the reader Transition Series readers are supplied with a 12-conductor cable pigtail, which is used to connect to the host panel. Refer to the cable conductors chart to correctly match the color of each wire. Refer to Wiring diagrams on page 13 for more information on connecting the reader: CAUTION: It is important to ensure all connections are made prior to applying power. Cable conductors Color Red Black Signal 6 to 16 VDC Ground Green Data 0 White Data 1 Orange Brown Yellow Gray Pink Tan Blue Purple Green LED Control Red LED Control Beeper Control Door DI REX DI Tamper Output Hold Reserved... Drain Wire 12 Transition Reader 500-PIV Series

Wiring diagrams See the following wiring diagrams for details on connecting the reader to the microcontroller: Wiegand Wiring Diagram on page 14 Wiegand 2SRP Wiring Diagram on page 16 ACU 2X or XL with an IKE Reader on page 18 ACU 2X or XL with RRE4 on page 20 ACU RS2/4 on page 22 Transition Reader 500-PIV Series 13

Figure 6. Wiegand Wiring Diagram 14 Transition Reader 500-PIV Series

Transition Reader 500-PIV Series 15 NOTES: 1. A 470 ohm, 1/2W, pull-up resistor may be required between +12 VDC and Reader Data 0 and Data 1. The pull-up resistor should be installed at the microcontroller s terminal block. Refer to the appropriate micro manual for installation requirements. 2. Shielded cable is required. Connect reader s drain wire to the cable shield. Connect shield wires at the microcontroller. Do not pair reader Data 0 and Data 1. 3. Blocking diodes must be 1N5817 or equivalent, located on the secured side of the door. 4. Protection diodes must be 1N4002, 1N4003, or 1N4004 for the door strike assembly. 5. Fuse, power supply, door strike, diodes, and relay are provided by the installer. 6. 2RP/2SRP boards are equipped with onboard door strike relay. Refer to the Micro5 Installation Guide.

Figure 7. Wiegand 2SRP Wiring Diagram 16 Transition Reader 500-PIV Series

Transition Reader 500-PIV Series 17 NOTES: 1. A 470 ohm, 1/2W, pull-up resistor may be required between +12 VDC and Reader Data 0 and Data 1. The pull-up resistor should be installed at the microcontroller s terminal block. Refer to the appropriate micro manual for installation requirements. 2. Shielded cable is required. Connect reader s drain wire to the cable shield. Connect shield wires at the microcontroller. Do not pair reader Data 0 and Data 1. 3. Blocking diodes must be 1N5817 or equivalent, located on the secured side of the door. 4. Protection diodes must be 1N4002, 1N4003, or 1N4004 for the door strike assembly. 5. Fuse, power supply, door strike, diodes, and relay are provided by the installer. 6. 2RP/2SRP boards are equipped with onboard door strike relay. Refer to the Micro5 Installation Guide.

Figure 8. ACU 2X or XL with an IKE Reader 18 Transition Reader 500-PIV Series

Transition Reader 500-PIV Series 19 NOTES: 1. Shielded cable is required. Connect reader s drain wire to the cable shield. Connect shield wires at the microcontroller. Do not pair reader Data 0 and Data 1. 2. Protection diodes must be 1N4002, 1N4003, or 1N4004 for the door strike assembly. 3. Fuse, power supply, door strike, diodes, and relay are provided by the installer. 4. For UL listed products do not use the door relay on the IKE reader.

Figure 9. ACU 2X or XL with RRE4 20 Transition Reader 500-PIV Series

Transition Reader 500-PIV Series 21 NOTES: 1. Shielded cable is required. Connect reader s drain wire to the cable shield. Connect shield wires at the microcontroller. Do not pair reader Data 0 and Data 1. 2. Protection diodes must be 1N4002, 1N4003, or 1N4004 for the door strike assembly. 3. Fuse, power supply, door strike, diodes, and relay are provided by the installer.

Figure 10.ACU RS2/4 22 Transition Reader 500-PIV Series

Transition Reader 500-PIV Series 23 NOTES: 1. Shielded cable is required. Connect reader s drain wire to the cable shield. Connect shield wires at the microcontroller. Do not pair reader Data 0 and Data 1. 2. Protection diodes must be 1N4002, 1N4003, or 1N4004 for the door strike assembly. 3. Fuse, power supply, door strike, diodes, and relay are provided by the installer.

Configuring the reader Transition Series readers are configured using setup cards, which are badges encoded with special instructions that change the reader s behavior. Configuration cards define a set of operational parameters such as output format, supervision, REX/DI operation, and LED indicators. There are two types of setup cards available: configuration cards and feature cards. Use the supplied configuration card to advance through modes (1-3) by presenting the card to the reader multiple times. The yellow LED and long beeps indicate changes in the reader s configuration. Feature cards enable or disable only one parameter at a time, such as setting the beeper on or off. Feature cards act like a switch inside the reader, turning a feature on or off each time the card is presented. The red or green LED and short beeps indicate changes in a particular feature. See Setup card summary on page 25 for a comparison of the two types of setup cards. 24 Transition Reader 500-PIV Series

Setup card summary Card Type Behavior LED Beeper Configuration Card Sequences through modes, advancing one position each time the card is presented. Yellow LED flashes one long flash N times. N equals the current mode value. One long beep N times. N equals the current mode value. Feature Card Toggles the feature on-to-off (disabled), or off-to-on (enabled) each time the card is presented. Disabled: Red LED flashes two times. Enabled: Green LED flashes three times. Disabled: Two short beeps. Enabled: Three short beeps. Using configuration cards Configuring the reader starts with identifying the configuration, or mode, that best fits your application. Refer to Appendix A for a listing of the currently supported modes. Once the mode has been identified, follow the steps below to configure the proper reader. CAUTION: It is important to ensure all connections are made prior to applying power. 1. Select the configuration mode. See Configuration card on page 30. 2. Place the reader in tamper mode by briefly removing and replacing the reader s cover while the power is on. The reader stays in tamper mode for a minimum of 60 seconds after power is applied or the cover is replaced. 3. Present the card to the reader. The yellow LED flashes and the beeper beeps a number of times equal to the mode value. For example, if the yellow LED flashes twice and the beeper beeps twice, the reader is in mode 2. Transition Reader 500-PIV Series 25

4. Remove the card from the field (approximately 8 inches away from the face of the reader) for two seconds and present the card again. Each time the card is presented, the mode value increases by one. If there are no additional modes, the value starts over beginning with mode one. When the configuration or mode of operation you have configured exactly matches the application, then configuration is complete and no feature cards are required. However, if the configuration requires modification, continue configuring the reader with a feature card. Once the configuration is set, it is stored in the reader and will not change even after power is disconnected or turned off. Using feature cards 1. Select the feature card from Configuration card on page 30 that supports the installation application. 2. Place the reader in tamper mode by briefly removing and replacing the reader s cover while the power is on. The reader stays in tamper mode for 60 seconds (minimum) after power is applied or the cover is replaced. 3. Present the card to the reader; observe the LED and beeper. If the red LED flashes twice and the beeper beeps twice, the feature identified by the card is disabled. If the green LED flashes three times and the beeper beeps three times, the feature is enabled. 4. Remove the card from the field (approximately 8 inches away from the face of the reader) for two seconds and present the card. Once the feature is configured, it is stored in the reader and will not change even after power is disconnected or turned off. 5. If required, select the next feature card and repeat the steps above. When all features have been configured, the reader is ready for use. 26 Transition Reader 500-PIV Series

Resetting the reader to a known state At times, it may be necessary to start the configuration process over again. Under these circumstances, it is best to reset the reader to a known state. To reset the reader: 1. Select a configuration card, and identify the correct mode value from Configuration card on page 30. 2. Place the reader in tamper mode as described above. 3. Present the card to the reader until the correct mode value is indicated by the yellow LED and beeper. 4. The reader is now in the appropriate mode and ready to be reconfigured using the feature cards. Transition Reader 500-PIV Series 27

Testing the reader To verify basic reader operation: 1. Ensure the reader is installed correctly. 2. Verify the reader is not in tamper mode. To do this, make sure the reader cover and base are securely joined. 3. Apply power to the reader and verify that the power-on self test completes. See Indicators on page 29. 4. Verify that the reader is not beeping and the red LED is not flashing. If either of these two conditions exist, refer to Indicators on page 29. 5. Verify proper reader operation. a. Ensure the door is securely closed. b. Present a badge to the reader, using a badge which is properly enrolled in the host system. c. Observe that the reader behaves as described in Indicators on page 29. d. Observe that the proper LED turns on, indicating a valid access has been granted. e. Open the door to verify the reader strike relay operates properly. 28 Transition Reader 500-PIV Series

Indicators GE indicators Condition Power-on Self Test Reader Ready Badge Read Valid Access Loss of Communication (Supervised) Tamper (Supervised mode) Indicators - Green LED flashes; two short beeps, - Yellow LED flashes; three short beeps - Red LED flashes - Yellow LED flashes Yellow LED on continuously Yellow LED flashes briefly, one short beep Green LED on until door strike is deactivated Red LED flashes slowly, three short beeps every 30 seconds Red LED flashes quickly, three short beeps every 30 seconds HID indicators Condition Power-on Self Test Reader Ready * Badge Read * Valid Access * Loss of Communication (Supervised) Tamper (Supervised mode) Indicators - Green LED flashes; two short beeps, - Yellow LED flashes; three short beeps - Red LED flashes - Yellow LED flashes Default setting. Yellow LED on continuously. Yellow LED flashes briefly, one short beep. Default setting. No LED indication.the LED color is set by the DO connection. Red LED flashes slowly, three short beeps every 30 seconds Red LED flashes quickly, three short beeps every 30 seconds * Note: Configuration cards can be used to change this setting. Transition Reader 500-PIV Series 29

Appendix AConfiguration card Card No. Mode Name Action 1 3 T-Series Wiegand (Factory default setting) Sets reader to output Wiegand protocol Sets output format by card technology as follows: - GE Proximity: 4002 12- digit output - HID Proximity: number of digits determined by card - PIV: 75-bit and 200-bit output 30 Transition Reader 500-PIV Series

Appendix BKeypad configuration For modes 1-6, follow these steps: 1. Place the reader in tamper mode by briefly removing and replacing the reader s cover while the power is on. The reader stays in tamper mode for 60 seconds (minimum) after power is applied or the cover is replaced. 2. Present the Configuration Card (See Appendix A) within one minute. Cycle through the modes until Mode 3 is reached. 3. Enter the keypad entry within five seconds. The LED turns green and a short triple-beep indicates the configuration is accepted. Use the following chart to identify the appropriate keypad entry. Output Format Key Press Sequence No Parity Formats Bits Sent Parity Press 1 Press 2 Press 3 Press 4 1 key 4 None 0 1 1 key buffer (Factory default setting) 2 key buffer 3 key buffer 4 key buffer 5 key buffer 6 key buffer 7 key buffer 8 None * 0 8 None 0 2 12 None 0 3 16 None 0 4 20 None 0 5 24 None 0 6 28 None 0 7 Transition Reader 500-PIV Series 31

Output Format Key Press Sequence No Parity Formats 8 key buffer 9 key buffer 10 key buffer 11 key buffer Parity Formats Bits Sent Parity Press 1 Press 2 Press 3 Press 4 32 None 0 8 36 None 0 9 40 None 0 * 44 None 0 # Bits Sent Parity Press 1 Press 2 Press 3 Press 4 1 key 6 2 bit 1 1 2 key buffer 3 key buffer 4 key buffer 5 key buffer 1 to 5 key buffer 6 key buffer 7 key buffer 8 key buffer 9 key buffer 10 key buffer 10 2 bit 1 2 14 2 bit 1 3 18 2 bit 1 4 22 2 bit 1 5 26 2 bit # 1 2 3 26 2 bit 1 6 30 2 bit 1 7 34 2 bit 1 8 38 2 bit 1 9 42 2 bit 1 * 32 Transition Reader 500-PIV Series

Appendix CWiegand I m Alive configuration card Card Settings Description Time Interval between I m Alive messages 1 (Factory default setting.) Off. No I m Alive message. (2 beeps, 2 red LED flashes) 2 1 sec. I m Alive message is sent every second. 3 beeps, 3 green LED flashes = enabled 3 5 sec. I m Alive message is sent every five seconds. 4 beeps, 4 green LED flashes = enabled Transition Reader 500-PIV Series 33

Appendix DHID indicator configuration card Card Setting Description 1 Ready LED color 1 (Factory default setting.) Yellow. 2 beeps, 2 red LED flashes = enabled 2 Red 3 beeps, 3 green LED flashes = enabled 3 Green 4 beeps, 4 green LED flashes = enabled 4 Off 5 beeps, 5 green LED flashes 2 Valid badge read LED color 1 (Factory default setting.) Off. The LED color is set by DO connection. 2 beeps, 2 red LED flashes 2 Green 3 beeps, 3 green LED flashes = enabled 3 Yellow 4 beeps, 4 green LED flashes = enabled 4 Red 5 beeps, 5 green LED flashes = enabled 34 Transition Reader 500-PIV Series

Appendix E Wiegand format definitions This section describes the different formats: See 4002 (40-bit format) on page 36 See 5502 (55-bit format) on page 38 See 6400 (64-bit format) on page 40 See GSA (75-bit format) on page 42 See FASC-N (200-bit format) on page 44 Some micros may require firmware customization to support Wiegand formats 5502 and 6400. Contact UTC Fire & Security Sales Engineering for assistance. Transition Reader 500-PIV Series 35

4002 (40-bit format) Summary 40 bits total 38 bits badge ID 2 bits parity 12 digits The first bit transmitted is the first parity bit, P1. It is even parity calculated over the first 20 bits. The last bit transmitted is the second parity bit, P2. It is odd parity calculated over the total 40 bits. 36 Transition Reader 500-PIV Series

4002 First bit Data P1-first P2-last 1 P1 E O 2 N E O 3 N E O 4 N E O 5 N E O 6 N E O 7 N E O 8 N E O 9 N E O 10 N E O 11 N E O 12 N E O 13 N E O 14 N E O 15 N E O 16 N E O 17 N E O 18 N E O 19 N E O 20 N E O 21 N O 22 N O 23 N O 24 N O 25 N O 26 N O 27 N O 28 N O 29 N O 30 N O 31 N O 32 N O 33 N O 34 N O 35 N O 36 N O 37 N O 38 N O 39 N O 40 P2 O Transition Reader 500-PIV Series 37

5502 (55-bit format) Summary 55 bits total 53 bits badge ID 2 bits parity 16 digits The first bit transmitted is the first parity bit, P1. It is even parity calculated over the first 27 bits. The last bit transmitted is the second parity bit, P2. It is odd parity calculated over the total 55 bits. 38 Transition Reader 500-PIV Series

5502 First bit Data P1-first P2-last 1 P1 E O 2 N E O 3 N E O 4 N E O 5 N E O 6 N E O 7 N E O 8 N E O 9 N E O 10 N E O 11 N E O 12 N E O 13 N E O 14 N E O 15 N E O 16 N E O 17 N E O 18 N E O 19 N E O 20 N E O 21 N E O 22 N E O 23 N E O 24 N E O 25 N E O 26 N E O 27 N E O 28 N O 29 N O 30 N O 31 N O 32 N O... 52 N O 53 N O 54 N O 55 P2 O Transition Reader 500-PIV Series 39

6400 (64-bit format) Summary 64 bits total 64 badge ID bits 0 bits parity 20 digits The 64-bit transmission consists entirely of code bits. The bits are transmitted in the order described below, from 1 to 64. (N represents the badge number, which is 20 digits.) 40 Transition Reader 500-PIV Series

6400 First bit Data 1 N 2 N 3 N 4 N 5 N 6 N 7 N 8 N 9 N 10 N 11 N 12 N 13 N 14 N 15 N 16 N 17 N 18 N 19 N 20 N 21 N 22 N 23 N 24 N 25 N 26 N 27 N 28 N 29 N 30 N 31 N 32 N.. 61 N 62 N 63 N 64 N Transition Reader 500-PIV Series 41

GSA (75-bit format) Summary 75 bits total 14 agency code 14 system code 20 credential number 25 expiration date 2 bits parity 14 digit badge number 42 Transition Reader 500-PIV Series

GSA First bit Data P1 P2 1 P1 2 A E : : : : : : : : : 15 A : 16 S : : : : : : : : : : 29 S : 30 C : : : : 38 : E 39 : O 49 C : 50 D : : : : : : : : : : 74 D O 75 P2 Data Elements: Parity 1 Parity 2 A = Agency Code S = System Code C = Credential Number D = Expiration Date P1 - Even P2 - Odd Transition Reader 500-PIV Series 43

FASC-N (200-bit format) Summary 200 bits total 20 Agency Code 20 System Code 30 Credential Number 5 Credential Series 5 Individual Credential Issue 50 Person Identifier 5 Organizational Category 20 Organizational Identifier 5 Person/Organization Association 40 Format and error check 44 Transition Reader 500-PIV Series

Table 1. 200-bit (FASC-N) Weigand Output for GE PIV Transition Readers Position Length (BCD Digits) Length (In Bits) SS 0 1 5 Agency Code 1-4 4 20 FS 5 1 5 System Code 6-9 4 20 FS 10 1 5 Credential Number 11-16 6 30 FS 17 1 5 Credential Series 18 1 5 FS 19 1 5 Individual Credential Issue 20 1 5 FS 21 1 5 Person Identifier 22-31 10 50 Organizational Category 32 1 5 Organizational Identifier 33-36 4 20 C A R D E N C O D I N G R E A D E R O U T P U T Person/Organization Association 37 1 5 ES 38 1 5 LRC 39 1 5 Notes: 1 Each BCD character is coded on 5 bits, out of which one bit is parity. 2 SS = Start Sentinel FS = Field Separator ES = End Sentinel 3 The data could be encoded on card, either in MSB or LSB format. Transition Reader 500-PIV Series 45

Regulatory approvals UL UL Listed Installations The following are the results of the UL evaluation of the Transition Series readers: Operating temperature range: -25 o F to 125 o F (31.67 o C to 51.67 o C) Relative humidity: 5% to 85% Power consumption: Model 500-PIV: 95 ma @ 12 VDC Model 520/525-PIV: 120 ma @ 12 VDC Read range: GE Proximity: up to 4.5 (11.43 cm) HID Proximity: up to 4.5 (11.43 cm) For UL listed products, do not use the door relay on the IKE reader. Request to exit terminals on the reader are not to be connected in UL listed installations. 46 Transition Reader 500-PIV Series

CE Manufacturers Declaration of Conformity For Product Identification: Model/type: 5XX(4302XX00X) BOM revision level: A Category (description): Reader Contactless Smart Card, Proximity Brand: UTC Fire & Security Manufacturer: UTC Fire & Security Suite 100 791 Park of Commerce Blvd. Boca Raton, Florida 33487 USA EU Representative: UTC Fire & Security B.V. Kelvinstraat 7 6003 DH Weert The Netherlands Concerning A sample of the product has been tested by: Test report reference Applied standards R&TTE EMC Safety Radio CKC Labs, Inc. 5473A Clouds Rest Mariposa, CA 95338 IM04-002 ETS04-013B ETS04-029B ETS04-028B EN301 489-3 v1.3.1 EN301 489-3 v1.4.1 EN50130-4 (1995 w/a1 :98 & A2 :03 CKC Labs, Inc. 5473A Clouds Rest Mariposa, CA 95338 FL 33525 ETS04-013A ETS04-028A ETS04-029A EN300330-2 v1.1.1 (06-2001) Equipment class identifier (RF products falling under the scope of R&TTE Not Applicable x None (class 1 product) (class 2 product) Means of Conformity: We declare under our sole responsibility that this product is in conformity with Directive 93/68/EEC (Marking) and/or complies with the essential requirements and all other relevant provisions of the 1999/5/EC (R&TTE) based on test results using (non) harmonized standards in accordance with the Directives mentioned. WEEE European directives The European directive Waste Electrical and Electronic Equipment (WEEE) aims to minimize the impact of electrical and electronic equipment waste on the environment and human health. For proper treatment, recovery and recycling, you can return the equipment marked with this symbol to your local supplier upon the purchase of equivalent new equipment, or dispose of it in designated collection points. Further information can be found on the following website: www.recyclethis.com European representative for manufacture: UTC Fire & Security, B.V., Kelvinstraat 7, 6003 DH Weert, The Netherlands Transition Reader 500-PIV Series 47

48 Transition Reader 500-PIV Series