Intelligent ways to save fuel heating your Commercial building. Caravan Modular Boiler System. CHS Multiple Boiler System

Similar documents
High efficiency, cast-iron gas boiler

SENTRY. High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY

VICTORYII. Cast-iron, power vent gas boiler BOILER FOR OLDER HOMES.

APPLICATION GUIDE. HOT WATER/GAS Modular Boilers CONTENTS INTRODUCTION OF FRESH WATER CODES AND STANDARDS LOCAL CODE APPROVALS

VICTORY VSPH VICTORYVSPH THE PERFECT CHOICE FOR. Cast-iron sealed combustion, direct vent gas boiler

Advanced Heating & Hot Water Systems. High Efficiency Residential & Commercial Space Heating

Gas-Fired Condensing Boilers A Green Start To Space & Water Heating

VICTORYVSPH THE PERFECT CHOICE FOR NEW RESIDENTIAL CONSTRUCTION RELIABILITY AND ECONOMY.

FXLF-9. High Efficiency Water Heaters and Boilers

MODEL M5M. High-Efficiency Packaged Watertube Boiler MMBTU

MASCOT II. Gas-Fired Wall-Mounted Combination Boiler & Water Heater

Endless water. Zero waste. Commercial. High-output, on-demand water heaters. iq Series, Gen II

STEAM / GAS APPLICATION GUIDE

Greenstar The World's Best Selling Condensing Boiler System

iq751/iq1001/iq1501 Specifications (Floor-standing units)

HYDRONIC SOLUTIONS. More than just hydronic boilers, we offer the most efficient integrated hydronic solutions on the market.

APPLICATION GUIDE HOT WATER/OIL CONTENTS WET-BASED CAST-IRON MODULAR BOILERS INTRODUCTION OF FRESH WATER CODES AND STANDARDS LOCAL CODE APPROVALS

INTRODUCING THE BRADFORD WHITE 24/7 EXPERT SUPPORT CENTER. TABLE OF CONTENTS. Technical Support: Warranty Support:

Raptor 320HB & 399HB Submittal Sheet

P-K MACH 'n' ROLL DOMESTIC HOT WATER AND COMFORT HEAT SYSTEM

clearfire Large capacity condensing boilers 4,000 to 12,000 MBTU/hr

VSL II QUICK START GUIDE

ULTRA HIGH EFFICIENCY CONDENSING BOILERS MILLION BTU/HR

ULTRA SERIES 4 HIGH EFFICIENCY CONDENSING BOILER

Phantom-X 399C/500C. Residential High Efficiency Gas Boilers PHNTM399C, PHNTM500C Submittal Sheet. Wholesaler Job Name Mechanical Contractor

SLANT/FIN AUTOMATIC VENT DAMPER For Galaxy, Sentinel and Sentry Series Boilers INSTALLATION INSTRUCTION MANUAL AND TROUBLESHOOTING GUIDE

HIGH EFFICIENCY COMMERCIAL BOILERS. Thermal Efficiency RIDE THE LOCHINVAR WAVE. Registered under U.S. Patent #9,746,176

Commercial Applications

ULTRA SERIES 4 HIGH EFFICIENCY CONDENSING BOILER HIGH EFFICIENCY CONDENSING BOILER

The WCGH High Efficiency Commercial Water Heater with Storage Tank

HIGH EFFICIENCY RESIDENTIAL BOILERS FIRE TUBE A PERFECT BOILER FOR EVERY NEED

Versa- Hydro. up to 96% Efficient

HIGH EFFICIENCY CONDENSING GAS COMBINATION BOILERS FIRE TUBE COMFORT DONE RIGHT. 95% AFUE Efficiency. f ive. nt y. pa rts w a

VSL II QUICK START GUIDE

BUDERUS. Quality. Versatility. Efficiency. Superior Design. Comfortable. Efficient. Intelligent Heating. Conventional Gas Boilers

96% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

P-K MACH HIGH EFFICIENCY, COMMERCIAL BOILERS

96% COMMERCIAL INDUSTRIAL HEATER. Condensing Gas Water Heating System. Thermal Efficiency

FXLF-4. High Efficiency Water Heaters and Boilers

Series 8H. Cast Iron Gas Fired Commercial Water Boiler

Highlights MBH 95% efficiency ENERGY STAR Qualified Low NOx emissions Space-saving design. 95% Efficient. Modulating Technology

10 : 1 Turndown Ratio

Qualifies for up to $ 1500 Energy Tax Credit! CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ALL NEW, ADVANCED USER FEATURES

Bosch Buderus SSB255/399/512 Stainless Steel Condensing Boiler

Date: Project #: Engineer: Prepared By: Bid Date:

CCLEARFIRE CONDENSING FIRETUBE BOILER DESIGNED FOR MAXIMUM HYDRONIC SYSTEM EFFICIENCY 500 TO 3,300 MBTU

AFUE 95% Heating Input 50,000 to 200,000 Btuh

EVERGREEN HIGH EFFICIENCY CONDENSING BOILER

CONDENSING HIGH EFFICIENCY BOILERS

95% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS REMOTE CONNECT CAPABLE CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

Condensing Boilers. High Efficiency. Proven Reliability, American-Made Home Heating Comfort. ANYWHERE UNMATCHED

Mascot. Gas-Fired Residential and Commercial Wall-Mounted Boiler. Easy Installation, 96% Efficiency, Fully Condensing

Commercial Gas Water Heaters

LAARS MINI-THERM Gas-Fired Residential Hydronic Boilers

APPLICATION GUIDE WET-BASE CAST-IRON MODULAR BOILERS

APPLICATION GUIDE HOT WATER/GAS

User s Information Manual

7 sizes: 55,000, 80,000, 110,000, 155,000, 199,000, 285,000 & 399,000 Btuh. One of a kind design from the inside, out!

RIELLO ARRAY. High Efficiency Condensing Boiler MBH.

MODEL EM-10 ELECTRIC BOILER CONTROL OPERATION AND INSTRUCTION MANUAL

CLEARFIRE HIGH-MASS CONDENSING FIRETUBE BOILER 500 TO 2,000 MBH

Bosch Greentherm Series

Heating Systems Company LAARS INTRODUCES. The MASCOT LX. A Boiler. An All-in-One Answer to Your Home Heating and Hot Water Needs

High Efficiency Commercial Gas Water Heaters

Product Data BW9 WATER BOILER SERIES B

Condensing Hydronic Boilers 2,000,000-6,000,000 BTU/HR

EVERGREEN HIGH EFFICIENCY CONDENSING BOILER EASY HEAT, EFFORTLESS COMORT

Seasonal Efficiency Longevity Part-Load Efficiency Condensing Operation Fast ROI MODULEX BOILERS MLX-1060 MLX-909 MLX-757

CONDEXA PRO EXCELLENCE AND VERSATILITY

AHRI Certified up to. 95% efficiency P-K MACH HIGH EFFICIENCY, COMMERCIAL BOILERS

Commercial Boilers and Domestic Water Heaters APG-5

Raypak Residential Products

LAARS MINI-THERM Gas-Fired Residential Hydronic Boilers

83.5 % UP TO 95 % 86.5 % High to Mid-Efficiency Residential & Commercial Heating Solutions. Boilers and Indirect Water Heaters

Bosch Buderus SSB1000TL/TL2/TL3/TL4 Stainless Steel Condensing Boiler

Boiler & Water Heater

Gas-Fired Condensing Boilers A Green Start to Space & Water Heating

TABLE OF CONTENTS BRADFORD WHITE BOILERS

- CAC. Commercial Air Conditioning Electrical Consumption Economizer

Technical Document Condensing hot water boilers

FAMILY PRO SIMPLY THE BEST

MECHANICAL VENTING VERSATILITY

Boilers Variable Fire Boilers

96.2% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT. MODBUS AND BACnet MSTP PROTOCOL

LAARS PENNANT. Economical efficiency for greater savings

Up To 99% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS WITH MODBUS PROTOCOL, CASCADING SEQUENCER AND FRONT-END LOADING CAPABILITY

C1050ES Tankless Water Heater

Heating Efficiency Program COLORADO

Crossover. Hybrid Water Heater HIGH EFFICIENCY. Advanced Heating & Hot Water Systems. w w w.htproducts.com

BUDERUS. Superior Equipment by Design. Comfortable. Efficient. Intelligent Heating. BUDERUS. G Cast Iron Commercial Boilers

Bosch Buderus SSB800/1000/1000TL Stainless Steel Condensing Boiler

TOTAL SYSTEM EFFICIENCY: AN INTRODUCTION TO CONDENSING BOILERS. David Grassl PE Mechanical Engineer Principal

HIGH EFFICIENCY COMMERCIAL BOILERS

Solar Energy Systems. Solar heating systems

CONDENSING BOILERS SMARTER & EASIER WITH 95% AFUE EFFICIENCY MAC COMBI MAH HEATING. with ARTIFICIAL INTELLIGENCE [AI]

Warmth, efficiency, and total peace of mind.

DATE PRODUCT WAS INTRODUCED TO THE CANADIAN MARKET: September 2018

Cast Iron Gas Boilers

Residential Product Selection Guide

Commercial Gas Water Heaters

Transcription:

Look for our Hydronic Explorer app on itunes, Google Play and at www.hydronicexplorer.com (Works on ipad, iphone & Android devices) Caravan Modular System Cast-Iron, gas or oil-fired, hot water or steam boilers. CHS Multiple System Modulating condensing gas-fired, high efficiency boilers. Since 199 BOILERS & BASEBOARD We Build Trust and Comfort Jaguar Multiple System Modulating condensing gas-fired, high efficiency boilers. Hybrid System Modulating high efficiency boilers with regular boilers Intelligent ways to save fuel heating your Commercial building www.slantfin.com

Large boilers waste fuel money because they re oversized 90 of the year. A typical single boiler s full output is generally needed for less than 10 of the year, when the coldest wether occurs. The rest of the time it wastes fuel because it fires at full capacity to meet a partial load. For much of the year, a single large boiler operates at less than 0 efficiency. Optimize hydronic heating efficiency in smaller commercial buildings with modular and multiple boiler systems. Proven again and again over the years that these boiler systems are more efficient than single large input boilers. They re also easier to install, especially in retrofit. Caravan modular boilers step-fire to use less fuel than a single big boiler. Step firing matches boiler output to load Reduces fuel bills by 0 to 0 Microprocessor controls monitor conditions, determine Caravan firing mode Wasteful short cycling eliminated 1 Controls and accessories for Caravan cast-iron modular boiler systems. SC-Series controls for Caravan modular boilers optimize performance and save energy for small or large systems. Slant/Fin SC-Series microprocessor controls maximize fuel savings of your Caravan modular boiler system. Not only do these smart SC-Series controls adjust supply water temperature based on outdoor and indoor air temperature, they actually anticipate future needs through computer logic. The controller then fires the right number of modules to maintain building comfort. Installer friendly. You enter simple parameters; the controller makes the calculations.the controller automatically calculates setpoint, reset ratio and control band. SC-Series control features Step-fires boiler modules using computer logic imizes fuel savings Monitors outdoor temperature to determine boiler water temperature Integrates control of space heating and domestic hot water Interfaces with building automation system Designed specifically for Slant/Fin Caravan gas, or oil-fired boiler systems Lead/lag equalizes equipment usage Easy to program Detailed, user-friendly documentation and high caliber factory support SC- Three stage operation.space heating only. SC-9 Nine stage operation. Space heating, domestic water or combination

Caravan Modular s: The smart way to heat your building. Gas-Fired Hot Water s GGT-00E GGHT-00E GGHT-0E GGHT-00E GGT-900E GGHT-100E GGHT-11E GGHT-100E GGT-100E GGHT-100E GGHT-100E GGT-100E GGHT-100E GGHT-10E GGHT-1E GGHT-000E GGHT-100E GGHT-0E GGHT-00E GGHT-0E GGHT-E GGHT-00E GGHT-00AE GGHT-000E GGHT-10E GGHT-00E GHT-E GGHT-00E GGHT-00E GGHT-0E GGHT-000E Modules 9 9 10 9 10 10 Module GG-00ES GG-0HES GG-HES GG-99HES GG-00ES GG-0HES GG-HES GG-99HES GG-00ES GG-0HES GG-HES GG-00ES GG-99HES GG-0HES GG-HES GG-99HES GG-0HES GG-HES GG-99HES GG-0HES GG-HES GG-99HES GG-0HES GG-HES GG-0HES GG-99HES GG-HES GG-0HES GG-99HES GG-HES GG-99HES C.S.A. Input 00 00 0 9 900 100 11 119 100 100 100 100 19 10 1 199 100 0 9 0 9 00 000 10 19 00 91 0 990 Ratings for Natural and L.P. Propane Gases. Output 0 0 9 909 9 9 11 11 1 1 11 11 19 199 11 0 0 9 00 0 Net Output 9 0 9 0 99 10 10 10 11 100 1 1 10 1 11 190 19 10 0 0 0 0 00 Net Rating (Sq. Ft.) Water 1 0 0 1 99 9 01 1 01 0 9 991 101 111 11 109 1 10 1 19 1 10 10 10 10 1.1 1. 1.1 1. 1.9 1.1 1. 1.1 1. 1. 1. 1. 1. 1. Caravan Modular System 00,000 to multi-million Btuh input Hot water and steam Gas, oil, power gas Working pressure to 100 psi efficiency up to 1.9 for gas, up to. for oil Gas Modules Cast-Iron Caravan Modules: Robust, long life design Big boiler heating capacity-small boiler simplicity Built-in back-up. If one module fails, the others continue to operate. Easy service with standard off the shelf controls and accessories. Lower maintenance cost -no special tools and controls needed 10 year factory limited warranty Advanced design cast-iron sections for long life Gas-Fired Steam s GXHT-00HEZ GXHT-900HEZ GXHT-100HEZ GXHT-100HEZ C.S.A. Input (BTU/HR) 00 900 100 100 Output 1 9 119 Oil-Fired Hot Water s LDWO-00-- LDWO-0-- LDWO-0-- LDWO-900-- LDWO-0-- LDWO-100-- LDWO-100-- LDWO-100-- LDWO-00-- LDWO-900-- LDWO-00-- Firing Rate (GPH) *.0.0.00.0.0 9.00 1.00 1.00 1.00 1.00.00 Oil-Fired Steam s LDZO-00-- LDZO-0-- LDZO-0-- LDZO-900-- LDZO-0-- LDZO-100-- LDZO-100-- LDZO-100-- Firing Rate (GPH)*...0.. 9.0 1.0 1.0 Input (BTU/HR) 0 0 9 109 10 10 100 0 90 0 Input (BTU/HR) 0 0 9 109 10 10 100 Net Rating (Steam) 1 9 Net Rating (Steam Sq Ft.) 19 9 0 Ratings for Oil Output 00 0 11 0 90 11 11 1 1 Modules Net Output 1 9 1 1 1 1 Ratings for Oil Output 9 99 0 9 10 19 1 Net Output 00 9 101 11 *Ratings apply to the use of oil at 10,000 BTU per gallon. 9.0 9.0 9.0 9.0 Net Rating (Water) (Sq. Ft.) 900 10 10 0 1000 10 10 10 Net Rating (Steam) (Sq. Ft.) 1 19 19 11 91 9 Modules Modules................... WHY ENGINEERS, BUILDING OWNERS AND HEATING PROFESSIONALS CHOOSE CARAVAN MODULAR BOILERS Step-firing saves fuel - boiler size changes to closely match boiler output to heating demand modules may be installed virtually anywhere in the building Lower installed cost, easier to service than large single input boilers Cast-iron heat exchangers provide long life, reliable performance Built-in standby, reliable Low maintenance Advanced microprocessor controls optimize energy savings Slant/Fin technical support is just a phone call away; specification details available online Slant/Fin Liberty Oil Fired Modules Net ratings are based on a piping and pick-up allowance of 1.1 for hot water & 1. for pick-up and piping allowances for steam. Slant/Fin should be consulted before selecting a boiler for installations having unusual piping and pick-up requirements. Ratings must be reduced by at,000 feet elevation and an additional for every additional 1,000 feet elevation over,000 feet.slant/fin should be consulted before selecting a boiler for installations having unusual piping and pick-up requirements. Based on 10 Btuh per square foot E.D.R at 10 F average water temperature. Based on 0 Btuh per square foot E.D.R. at 1 F steam temperature. For use with natural gas. For Propane (L.P.) gas consult factory. NOTES: 1. Many state and local codes require intermittent ignition devices for gas boilers. Please specify if necessary.. FOR LARGER SIZES, USE MULTIPLES OF THE ABOVE. Modules in excess of those shown above should be piped in parallel in two or more batteries. FOR COMPLETE SPECIFICATIONS, REFER TO CARAVAN APPLICATION GUIDES AND ENGINEERING BULLETINS.

High efficiency boilers: The clever way to heat your building. Condensing Multiple Systems The Jaguar Modulating Condensing High Multiple System Up to 9.1 thermal efficiency at minimum input 90,000 Btu s max input per boiler Modulation down to,000 Btu s For single and multiple boiler applications PVC venting up to 100' Cast aluminum alloy heat exchanger Natural Gas Built-in digital cascading control with outdoor reset for up to boilers Floor Standing Up to 0psi max working pressure (ASME) Aluminum Heat Exchanger Dimensions: " H x " W x 0" D Built-in cascading control for up to boilers Ratings CSA Input Min output Net at imum Input Combustion at imum Input J-90 90 0 90. 91. Jaguar Multiple Ratings (Based on performance of J-90 ) Htg. Consists of J-90 J-90 J-90 J-90 J-90 J-90 J-90 Input output Min Min 0 10 190 0 0 10 0 10 10 10 11 1 1 91 1 10 1 1 Net output Turndown Ratio 9 9 9 9 9 9 9 to 1 10. to 1 1. to 1 1. to 1 1. to 1. to 1. to 1 Net ratings are based on piping and pick-up allowance of 1.1. Slant/Fin should be consulted before selecting a boiler for installation having unusual piping and/or pick-up requirements.

High condensing boilers maximize fuel savings. With efficiencies up to 9, it is easy to get dramatic fuel savings over other typed of systems. The advanced technology of either the Jaguar or CHS is the perfect way to save fuel. Condensing Multiple Systems The CHS Modulating Condensing High 9 Stainless steel, down-fired fire tube design Two models 00 and 99,000 BTU/Hr Full modulation: :1 turndown Advanced Honeywell Sola Controller with backlit screen display Low NOx operation Environmentally friendly Venting to 10' Free standing or wall hung ASME Certified Heat Exchanger - up to psi Top or Bottom Connections Natural or L.P. gas Cascading control for up to boilers Exhaust Manifold Exhaust Manifold / per foot slope Ratings CHS-99 CSA Input output Min Net Combustion CHS-99 99 0 0 9. 9 B or Common Venting Option s Input Min output Net Rating Water Content Gal. Turndown Ratio CHS99 CHS99 CHS99 CHS99 CHS99 CHS99 CHS99 9 119 19 199 9 9 19 0 10 1900 0 0 00 0 990 10 10 190 10 0 1. 19...0 0.. 1. 10 to 1 1 to 1 0 to 1 to 1 0 to 1 to 1 0 to 1 Ratings CHS-00 CSA Input Min D.O.E. Capacity Net AFUE CHS-00 99 9 9 CHS00 CHS00 CHS00 CHS00 CHS00 CHS00 CHS00 s 9 9 119 19 19 09 9 Input Min D.O.E. Capacity 111 190 1 19 Net Rating 1 9 119 1 1 191 Water Content Gal. Turndown Ratio Stainless Steel Heat Exchanger For other Caravan Ratings & Specifications, go to www.slantfin.com 1. 19...0 0.. 1.. to 1 11. to 1 1 to 1 1. to 1. to 1. to 1 0 to 1

Hybrid boiler systems: Definition, Sizing, and... The shrewd way. The Hybrid System Now you can add one or more High boilers to a traditional large boiler system or a modular system such as Slant/Fin s and achieve almost the same energy savings with this hybrid system as you would with an all high efficiency system but at a much lower installed cost. What is a Hybrid System? A Hybrid System is a combination of two types of boilers used in the same system. Slant/Fin Hybrid Systems combine high efficiency condensing boilers with non condensing cast iron boilers. Why combine Condensing boilers with Non-Condensing boilers? Simply put, we combine both types of boilers because condensing boilers operating efficiency is over 90 only when the system water temperature is lower. When system water temperatures are higher a condensing boiler operating efficiency is not much higher than our non condensing boilers. A Hybrid System optimizes the use of both condensing and non-condensing boilers delivering a cost effective, yet efficient heating plant. Lower first cost, lower maintenance costs and longer boiler system life are expected with a Hybrid System. How do you decide the make up of a Hybrid System? On most existing hot water heating systems generally two thirds of the boiler system capacity will be in the non-condensing water temperature range and one third of the capacity is in the condensing water temperature range. Condensing water temperature is 10 F or lower and above 10 F water temperature we are above the condensing water temperature. Your mechanical engineer can calculate what percentage of your heating load can be satisfied in the condensing water temperature range and therefore, choose the condensing boiler capacity for your heating plant. What can you expect with a Slant/Fin Hybrid boiler system? Combining our non-condensing Caravan s with our Jaguar or CHS condensing boilers lowers your equipment and installations first cost while optimizing operating performance of the boilers with the result of low fuel costs. You should also have lower maintenance costs while increasing the life expectancy of both types of boilers. In addition you will have boiler back up in the unlikely event a boiler fails to operate. Hybrid Systems optimize the performance of both types of boilers! Copyright Slant/Fin Corp, blg. 10/09/01

Hybrid System Control As with any boiler system, it is important to properly control a hybrid boiler system. The goal is to optimize comfort and efficiency, minimize maintenance and maximize product life expectancy. End result should be good savings-to-investment ratio and return on investment. 100 9 9 Effect of Inlet Water Temperature on s, ref. ASHRAE Handbook NATURAL GAS = 100 Btuh/ft The condensing boilers are the most expensive equipment, have the higher maintenance cost and tend to have a shorter life span. Therefore, the goal is to operate the condensing boilers when they condense and have them in stand-by when they will not condense or when their operating efficiency drops. This decreases maintenance and increases expected product life. BOILER EFFICIENCY 9 9 90 CONDENSING BOILER NON-CONDENSING BOILER DEW POINT The non-condensing boilers are less expensive, have lower maintenance costs and have a longer life span. In addition, non-condensing boilers should not condense. Therefore, the goal is to operate them when the system water temperature is above the condensing range and have them in stand-by when water temperature is in condensing range. Operating them only when they do not condense decreases maintenance costs and increase expected product life. 0 10 EXCESS AIR 0 0 10 10 00 0 INLET WATER TEMPERATURE F The approximate water temperature range for condensing is below 10 F and the non-condensing return water temperature range is above 10 F. Very simply put, operate the condensing boilers when water temperature is in the condensing range. When water temperature is above the condensing range, shut the condensing boilers off and have the non-condensing boilers handle the load. If and when the non-condensing load exceeds the capacity of the non-condensing boilers (reaches peak demand), bring the condensing boilers back on line. As a general statement, if a hybrid boiler system is not oversized, peak demand may occur to 10 days during a heating season. Please remember, boiler systems tend to be oversized. A properly controlled hybrid boiler system maximizes boiler system life span and return on investment, while minimizing life cycle costs. system control manufacturers, such as, Heat Timer and Tekmar, offer nice Hybrid System controls that will coordinate operation of condensing and non-condensing boilers. Outdoor temperature boiler water reset is generally built into these controls. ONLINE RESOURCES Engineers web link: http://slantfin.com/professionals/engineer-info/ Technical Services: http://slantfin.com/professionals/technical-assistance/ E-mail: techservice@slantfin.com ph: (00) - US: www.slantfin.com Canada: www.slantfin.ca

Practice what you preach... In the fall of 01, Slant/Fin upgraded our home office s Caravan System to a Hybrid System. The existing non-condensing Gas-Fired Caravan boiler remained we added two high efficiency condensing Jaguar J-90C boilers in a primary/secondary piping arrangement to the boiler return water piping to the existing Caravan boiler system and made it a hybrid system. We upgraded the control system to a CNC step control with outdoor water temperature reset. This replaced the existing step controller with outdoor reset. The control fires the high efficiency condensing Jaguar boilers only when the system water temperature is within the condensing range. It also modulates Jaguars boiler input to maximize efficiency. When the water temperature is above the condensing range, the existing Caravan modular boiler handles the heating load and the Jaguar boilers are turned off. If the existing Caravan cannot handle the maximum heating load, the Jaguar boilers will come on line to meet the heating demand. Condensing boilers condense only when the water temperature is low and in the condensing range. The result was a payback of one heating season. In addition, there is less usage on the more expensive condensing boilers, resulting in an increased life expectancy, along with lower maintenance costs! Since 199 BOILERS & BASEBOARD We Bu ild Trust and Comfort U.S.A. Slant/Fin Corporation 100 Forest Drive Greenvale, NY 11 1--00 www.slantfin.com Canada Slant/Fin LTD/LTEE 0 Northam Drive Mississauga, Ontario LV 1H9 90--00 www.slantfin.ca Slant/Fin Corp. 01 Printed in the U.S.A. 1 Publication C-10