TECHNICAL SPECIFICATION

Similar documents
TECHNICAL SPECIFICATION

Models Vallox 096 MC R Vallox 096 MC L. Document D2609 MANUAL. Valid from Type Updated Manual.

Vallox INSTRUCTIONS FOR USE AND MAINTENANCE. Compact. Supply and extract air ventilation with heat recovery

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter

TECHNICAL SPECIFICATION

145SE. Vallox. Operating, maintenance and technical instructions

096SE. Vallox. Operating, maintenance and technical instructions

Vallox Oy. manufactures ventilation units Vallox TSK Multi 80 MC. over Vallox TSK Multi 80 MC

Heat recovery unit RDKS

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

Vallox Oy. manufactures. over LOW POWER EFFICIENCY Specific electrical

KN-KWL 110 SE-EC Kontrollierte Wohnraumlüftung KN

KOMFORT EC DB Suspended heat recovery air handling units

Manual. Document ENG

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

Itho Advance heat recovery ventilation unit. comfortable. indoor climate

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing

121 SE. Vallox. Low-energy ventilation unit with heat recovery. Operating, maintenance and technical instructions

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

VALLOX VENTILATION PRICELIST 2018

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT

MRXBOXAB-ECO3 MRXBOX-ECO3

MRXBOXAB-ECO2 MRXBOX-ECO2

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

ROOM-BY-ROOM DEMAND CONTROLLED HEAT RECOVERY VENTILATION

IN LINE MIXED FLOW DUCT FANS AND ELECTRIC HEATER TD-MIXVENT HEATING System

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

GLEC exhaust FAN. Air Comfort. Air movement. Duct & Box Fans

Centrifugal air heaters hot water or electrical supply

Flexit air handling units C2 and UNI 2, 3,4

The new Xcell EC High Efficiency Range Fresh air pure and simple

REKO heat recovery units REKO HEAT RECOVERY UNITS TYPE A TYPE D

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

Brise speed speed control 2. BRIC ceiling model 3. BRIW wall model 4. BRBW wall build-in model 5. grille from ABS 6.

Ventilation Unit Zehnder ComfoAir 350

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

Eco Active H E A T R E C O V E R Y S Y S T E M S. Heat Recovery Penthouse Turret. W: T:

Whole Home Heat Recovery Ventilation

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

TECHNICAL INFORMATION HCV 4 - HCV 5 - HCH 5 - HCH 8 Demand-controlled home ventilation

AIR HEATING UNIT HEATMASTER ACJB INSTALLATION, OPERATION, MAINTENANCE AND SPARE PARTS

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

CI/SfB (57.5) November 2008

Flexit air handling units UNI 2, 3 og 4

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

Koja Oy. manufactures ventilation units Fair 80 ec

Swegon CASA R85. Ventilation unit with rotary heat exchanger HOME VENTILATION

DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION

BATHROOM EXTRACT FANS SILENT-100 Series

SOUNDER BASES AND SOUNDER BEACON BASES

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

STR-600 Impact Dryer

2013 innovation. Room-by-room demand controlled heat recovery ventilation

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h

Lo-Carbon Sentinel Kinetic Horizontal

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

66 on. Central ventilation system ZLS-DV EC according to DIN Central ventilation system ZLS EXTRACT AIR FIRE PROTECTION OUTSIDE AIR

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING

SERIES FAN VAV TERMINAL BOXES TYPE CVFB & SFTB

VENTILATION & HEATING CATALOGUE.

Ventilation unit Zehnder ComfoAir 200

MODEL: BV400 Part No:

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

Overview and Specifications

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

Product Data INDUSTRY LEADING FEATURES / BENEFITS

That allows for installation of a lowresistance ducts system directly from the appliance. CONSTANT FLOW FANS

ECOCIAT. Domestic hot water heat recovery unit. Use. Range

DOMEKT. Heat Recovery Air Handling Units

Apartment Ventilation. "Microbox" Continuous Mechanical Extract Units

FLEXIT S4 X/TT - A4 X/TT S7 X/TT - A7 X/TT

COUNTER-FLOW, HIGH-EFFICIENCY HEAT RECOVERY UNIT IDEO ECOWATT

S ILENT Series INSTALL SILENCE, INSTALL QUALITY OF LIFE. The Quietest Extractors in the World in their Category 26,5

PRODUCT DATA COMPACT S BY NILAN. Sanitary hot water production. Passive heat recovery. Comfort heating. Ventilation < 375 m 3 /h. Active heat recovery

FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 %

Breathe Fresh Air at Home

HRU ECO 4. System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible

VIESMANN VITOVENT 300-F Mechanical ventilation system with heat recovery

HOTLINE:

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

> ENGLISH VERSION. Instructions HERU 50 HERU / utg 2

Heat and energy recovery ventilators

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

ENERGY RECOVERY VENTILATION (ERV)

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

NEW VENTILATION AIR CONDITIONING AIR CLEANING HEATING SAP-Q APPENDIX Q ELIGIBLE

IDEO 325 ECOWATT. Counter-flow, high-efficiency heat recovery unit IDEO 325 ECOWATT. Low noise. Heat recovery units. Wireless programmable control

Transcription:

Vallox 50C FFCT.09.79b.8.009 Code 5 VALLOX Code 5 TCHNICAL PCIFICATION For dwelling-specific ventilation upply and extract air ventilation with heat recovery ilent operation nergy-efficient unit; high-efficiency cross-counter-cell and direct current fans Good filtering Fixed air flow measurement outlets Fan speed adjustment with a switch HR bypass as a standard feature lectrical connection Class of protection IP Fans xtract air 0.75 kw 0.76 A 6 dm /s (00 Pa) direct current (DC) upply air 0.75 kw 0.76 A 6 dm /s (00 Pa) Heat recovery Heat recovery bypass Preheating radiator (option) Counter-current cell, easonal damper lectric, 000 W >80 % Filters upply air xtract air G and F7 (F7 optional) G Weight 0 kg Ventilation adjustment options Options 0 V, 50 Hz,,5 A (preheating radiator. A) peed selection switch (standard) - upply air filter F7 - Preheating radiator

DIMNION AND MAIN PART Dimensions and duct outlets VALLOX 50 ffect C 78 Model L in the figure 7 9 6 9.5 0 5 89 87 89 8 5 60 6 50 00 5 59 Model R 5 85 09 89 87 89 Main parts upply air fan 8 upply air filter F7 (option) 5 xtract air fan 9 Outdoor air filter G 6 5 59 50 60 5 6 Heat recovery cell ummer / winter damper ummer / winter damper lock afety switch 0 0 xtract air filter G Preheating radiator (option) Plug peed selection switch 09 85 5 7 Measurement outlets Model L Duct outlets, inner diameter of collar ø 00 mm Outdoor air to the unit xtract air from the dwelling upply air to the dwelling xhaust air outside Unit weight 0 kg

VALLOX 50 ffect C PRFORMANC Air volumes Measuring points after the connection outlet. UPPLY / XTRACT AIR VOLUM /50 ffect C = xtract air fan (G filter) = upply air fan (G filter) FP = input power (total) (W) air flow (max.) (dm /s) Fan curves indicate the total pressure available for duct losses. Pa 50 upply air xtract air 00 50 00 50 00 50 0 FP.5 kw/m /s RCOMMNDD OPRATING RANG = 0 V 8, V =, V,9 V 5, V =6 V 6,5 V = 7, V 0 0 0 0 50 60 70 80 90 00 0 0 0 0 50 dm /s Volume flow rate Fan speeds Fan input power W Abluftstrom l/s ound values ound power level from the ventilation unit to supply air ducts by octave band Lw, db ound power level from the ventilation unit to extract air ducts by octave band Lw, db 5 90 80 0 0 80 0 5 Hz l/s ADJUTMNT POITION / AIR FLOW 7 l/s 96 l/s 6 l/s 5 l/s ADJUTMNT POITION / AIR FLOW 6 8 85 l/s 0 l/s l/s Medium frequency of the octave band, Hz 6 5 50 500 000 69 55 8 75 68 5 8 7 58 8 8 77 6 5 7 7 56 9 76 6 5 80 7 58 7 5 8 75 6 5 8 000 6 9 7 6 9 000 7 6 9 9 8000 5 0 0 L W, db 69 76 8 8 7 77 8 8 L WA, db(a) 5 5 58 6 A-weighted sound pressure level db (A) coming from the unit through the envelope to the rooms where the unit has been installed (0 m sound absorption) ADJUTMNT POITION / AIR FLOW (supply / extract) 0/7 l/s 80/8 l/s 00/09 l/s 0/0 l/s 7 5 58 VALLOX 50 ffect C 6 L pa, db(a) 7 6 7

VALLOX 50 ffect C OPRATION D C F B ummer / winter damper in summer position ummer / winter damper in winter position peed selector A Heat recovery bypass In winter use the heat recovery cell of VALLOX 50 ffect C recovers heat from the air leaving the dwelling and uses it to heat the air coming from the outside. In summer use when it is warm outside, it is unnecessary to heat outdoor air. The heat recovery cell is then bypassed in VALLOX 50 ffect C with the standard damper (A). The position of the damper can be changed by opening the damper release (B) and then moving the seasonal damper in another position. In the summer position air flow through the cell is prevented, and heat recovery bypass is activated. Air filtering VALLOX 50 ffect C features G coarse filtering (C) of both extract and supply air before the fans. The unit can also be equipped with an F7 fine filter (D), which captures fine dust and pollen as well as dust not seen to the eye. The filters need to be in place in the unit whenever ventilation is in operation. Antifreezing Water condensing from extract air may freeze in the heat recovery cell. Freezing can be prevented by stopping the supply air fan, or the unit can be equipped with a preheating resistor, which is switched on as needed. topping the supply air fan The antifreezing thermostat T stops the supply air fan whenever the temperature of extract air is below +5 C after the cell. The fan restarts when temperature has risen by circa three degrees, i.e. to 8 C. The limit of the thermostat () can be adjusted. If the unit includes a preheating radiator (F), the supply air fan cannot be stopped. Outdoor air preheating The unit can have been equipped with a preheating radiator at the factory. If that is the case, the antifreezing thermostat T switches the preheating radiator on whenever the temperature of extract air goes below +5 C after the cell. The preheating radiator is switched off when temperature has risen by circa three degrees to +8 C. The preheating radiator heats outdoor air before the heat recovery cell and prevents it from freezing. In very cold temperatures the preheating radiator is not enough to heat maximum air flow to a sufficient degree (in a temperature of -0 C, maximum air flow is 0 dm /s, corresponding to speed ). election of fan speed Fan speed is selected by using a separate speed selector. peed selector The speed selector can be used to select speeds,, and :. Use during absence. When the dwelling is empty, ventilation can temporarily be diminished. -. Normal use. In normal conditions air needs to be replaced once in two hours.. Boosted operation. Cooking, bathing in the sauna or bathroom, drying clothes, using the toilet, having guests or a similar situation may cause a need for higher than normal ventilation. NOT! The positions of the speed selector switch have been given preset values at the factory. The corresponding air volumes are indicated in the performance table on page. When needed, the preset values may be changed by adjusting the potentiometers in the speed selector switch. (ee separate instructions for Vallox imple Control.) Post-heating For most of the year, heat recovered from the air being extracted is enough to warm the cold air coming from the outside to a suitable temperature. If the heat of extract air is not enough, air coming from the outside may be heated further with a radiator installed outside of the unit (for instance VALLOX 000 supply air heater).

VALLOX 50 ffect C INTRNAL CONNCTION DIAGRAM 0 VDC + F F L LP T K = upply air fan = xtract air fan = arthed wire = Preheating radiator (option) = afety switch = Antifreezing thermostat upply air fan stops at +5 C (Preheating radiator on at +5 C if preheating radiator installed) = Choke C () () T T C () K () 0 VDC + N L L N L N GNY BN L Y BN RD RD GNY GNY BK BN Y BN RD RD GNY GNY BN BK 80 C 80 C 0 C F F R LP 5

XTRNAL CONNCTION DIAGRAM VALLOX 50 ffect C + - Vallox imple Control switch x 0.5 mm x 0.5 mm Voltage signal 0...0 VDC Remote monitoring control centre of the property (Control option) 0 VDC + VALLOX 50 ffect C Plug connection 0 A.8 m from the top of the unit 6

VALLOX 50 ffect C CONTROL DIAGRAM AND DCRIPTION OF OPRATION RMOT MONITORING CONTROL CNTR OF TH PROPRTY CONTROL DITRITION PANL 0 A 0V 50Hz PLUG VALLOX 50 FFCT C INTRNAL LCTRICAL AND CONTROL CONNCTION ILNCR ILNCR G G M F F7 PD LCTOR TZ PRHATING RADIATOR TZ LP HR FG T F M VNTILATION ZON Control of operation Power supply to the unit can be controlled with the 0/ switch in the distribution panel if needed. After starting, the unit operates at the power selected on the fan speed adjustment switch. There is also a safety switch inside the unit. It stops power supply when the maintenance door of the unit is opened. Fan speed adjustment Cam switch The F and F fans of the unit are controlled depending on usage with a separate -step (,, and ) cam switch located in the ventilation zone. Voltage signal control The fan power of the unit can be controlled steplessly with voltage signal 0...0 VDC. With a voltage signal lower than.5 VDC, the fans stop. upply air temperature The unit does not have a post-heating radiator for controlling the temperature of supply air. It is possible to connect a separate supply air heater (e.g. VALLOX 000 supply air heater). Heat recovery bypass witching to summer-time bypass (FG) of the heat recovery cell HR is done manually by turning the HR damper to the bypass position for the summer. Heat recovery antifreezing The antifreezing thermostat T of the HR cell stops the supply air fan F, preventing the HR cell from freezing. The fan starts automatically as soon as the risk of freezing has passed. The operating point of the antifreezing thermostat can be changed, the factory setting is +5 C. The unit can also be equipped with a preheating radiator LP, controlled by the antifreezing thermostat T. When there is a risk of frosting, the preheating radiator LP starts to heat air coming from outside to the unit, thereby preventing the HR cell from freezing. Parts list VALLOX 50 ffect C Code Name Technical data tandard / (factory settings in parentheses) Option G Filter upply air G + F7 (option) tandard F7 xtract air G FG HR bypass damper Manual tandard HR Heat recovery cell Counter-current cell, efficiency 80 % tandard F upply air fan (DC, direct current) qv = 6 dm /s (00 Pa) tandard T HR antifreezing thermostat Factory setting +5 C tandard F xhaust air fan (DC, direct current) qv =6 dm /s (00 Pa) tandard -step adjustment switch,,, switch tandard LPl Preheating radiator 000 W Option TZ Overheat protection Automatic, +0 C Included in for the heating element LP TZ Overheat protection Manually reset, +80 C Included in for the heating element LP 7

VALLOX 50 ffect C INTALLATION A Location of the ventilation unit The unit is mounted indoors, in a place where temperature does not fall below +0 C. The unit is mounted in a place where the sound pressure level coming through the envelope is not acoustically disturbing (storerooms, corridors, technical rooms, and in some cases rooms where people spend time). The unit is equipped with an adjustable base. If the unit is mounted on the wall, attention needs to be paid to the weight of the unit (0 kg) and to vibration isolation. The unit is splash protected (IP ) and can thus also be mounted in a damp room. D B C lectrical connections The unit has a plug connection.the electrical connection box of the unit is located inside the unit next to the connection outlet of the exhaust air ductwork. The cables to be connected to the unit are wired through the lead-in seals () located next to the connection outlet of the exhaust air ductwork. A B C D Duct outlets Measurement outlets Base plate Top panel Lead-in seals Installation Remove the door of the unit (latches on top edge). Remove the cover of the electrical connection box ( screws.5 x 9.5). Mount and connect necessary cables to the terminal block as specified in the connection instructions. These instructions include the internal and external electric diagrams. Channel outlets of the unit The unit is equipped with four ø 00 external connection outlets. Necessary connecting pieces (e.g. inner or bent connectors) can be attached to external connection outlets. NOT! LNGTH OF TH CONNCTING HAD OF TH CONNCTING PIC NO MOR THAN 5 MM. Fix the ducts steadily and tightly to the relevant outlets. (NOT! Unit models L/R). Implement duct insulation if needed as defined in the ventilation plan. Air flow measurement outlets The fixed air flow measurement outlets are located behind the top panel (D). To remove the top panel, open its fixing screws. Via the measurement outlets (B), you can messure the total pressure of the supply and extract air ductwork with a differential pressure instrument. Pressure readings and the unit s air volume tables (p. ) show volume air flows at various adjustment positions. The red measurement hose is on the pressure side and the black hose on the suction side of the fan. 99 Condensing water connections 7 The delivery includes a water seal. With a pipe connected to the water seal, water condensing from extract air can be led to a floor drain (not straight to the drain). The pipe must not rise after the water seal. As the screw-type coupling is located in the middle of the unit, the unit has to be mounted level with the horizontal. condensing water outlet Vallox Oy FI-00 Loimaa Finland Telephone +58 766 00 Fax +58 76 59 www.vallox.com.09.79b/.8.009/pdf