ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

Similar documents
Indicates incorrect room temperature. No second stage or AUX heating. Emergency heat does not turn on

No fan function in heat mode. Fan ON continuously. Indicates incorrect room temperature

Safety & Installation Instructions

Safety & Installation Instructions

Safety & Installation Instructions

IF79 CAUTION CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS. Installation Instructions for. Heating & Air Conditioning

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

WARNING Important Safety Information

SMART TEMP UNIVERSAL 7-DAY PROGRAMMABLE THERMOSTAT (FOR BOTH CONVENTIONAL AND HEAT PUMP SYSTEMS) INSTALLATION AND OPERATING INSTRUCTIONS

Operator: Save these instructions for future use!

WARNING Important Safety Information

ATP21W02 CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS REMOVING OLD THERMOSTAT 2 THERMOSTAT DETAILS

Smart Temp. Model

Safety & Installation Instructions

7-DAY or 5/2-DAY PROGRAMMABLE, OR NON-PROGRAMMABLE THERMOSTAT INSTALLATION AND OPERATING INSTRUCTIONS

T-32-TS Touchscreen Thermostat. Installation Manual

1F Non-Programmable Electronic Digital Multi-Stage Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

Install Guide CT100. Caution. Caution

Emerson Blue Easy Set 1H/1C

For Quick Set-Up go to Page 14

1F Non-programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

WARNING Important Safety Information

WARNING Important Safety Information

WARNING Important Safety Information

IntelliSync Thermostat / Mobile App Frequently Asked Questions

Installer Guide. WARNING Important Safety Information. 1 Specifications

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

PSP722E LARGE HYBRID DISPLAY WITH ELECTRO-LUMINESCENT DISPLAY BACKLIGHT UP DOWN IAQ INDEPENDENTLY PROGRAMMABLE FAN

Smart Temp. ApolloP/n Installation Manual. Version 1.0

USER MANUAL MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat

(-)HC-TST213UNMS 5/1/1 Day 5/2 Day Non-Programmable. Yes

Installer Guide. WARNING Important Safety Information. 1 Specifications

Programmable Thermostat. Installation, Operation and Maintenance Manual Effective January 2017

FOR BOTH CONVENTIONAL AND HEAT PUMP SYSTEMS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT!

Programmable Thermostat

Detailed Installer Guide

Comfort System T-21-P Touchscreen Thermostat Installation Manual

Installation, Programming and Operating Guide for Digital, Programmable Thermostat with Smart Fan Technology. with SFT (Smart Fan Technology )

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION. Premier Series

USER MANUAL 2000NC MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. Builder Series 5-2 Day Programmable Single Stage Heat/Cool Digital Thermostat

DAY/TIME Button: Selects hour, minute and day setting.

T8602C Chronotherm IV Deluxe Programmable Thermostats

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

PRO Installation. Thermostat Wi-Fi

CT2800 Programmable Thermostat

USER MANUAL WARNING! CONTENTS MODEL SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING

PRO Installation. Touch Wi-Fi Thermostat

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION

DAY/TIME Button: Selects hour, minute and day setting.

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

HEAT COOL 5+2 DAY PROGRAMMABLE 1-STAGE HEAT, 1-STAGE COOL. Installation Instructions TSTATCCPQ501 TSTATBBPQ501 P Digital Thermostat I2:00

Owner s Manual. Digital Thermostat. Non-Programmable

Installation Settings Guide

DP711. PurePro DP711 INSTALLATION AND OPERATING INSTRUCTIONS

Programmable Thermostat

PSPA711/PSPA _PSPA711_722_MAN_ENG5.qxd 2/8/05 9:45 AM Page 2 1 COMPATIBILITY 3 ELECTRICAL RATINGS 2 FEATURES

Commercial Touchscreen Thermostat

Set & $ave. Model Programmable Thermostat. installation and operation manual

T7200D,E Series 2000 Commercial Microelectronic Thermostats

SAS6000UTK-7 UNIVERSAL THERMOSTAT

User s Manual Quick Start Installation and Programming

Product Manual SZ1009

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

P200 Programmable Thermostat Installation Instructions & User Guide. For Installation Help. White-Rodgers.com

EL-TSTAT-8820 Safety & Installation Instructions

PRO Installation. Touch Wi-Fi Thermostat

T8624D Chronotherm IV Deluxe Programmable Multistage Thermostats

RTH8500 Series. Quick Installation Guide. Included in your box. Programmable Thermostat. Quick Install Guide Screws and anchors. RTH8500 Thermostat

MagicStat CT3300 Programmable Thermostat

Operator: SaVe these instructions forfuture use

Owner s Manual. Digital Thermostat

SC Installation, Operation & Application Guide

1F95EZ-0671 Non-Programmable 7 Day. Maximum Stages Heat/Cool 1/1 2/2 3/1 4/2

SC Installation, Operation & Application Guide

T7300F Series 2000 Commercial Microelectronic Conventional or Heat Pump Thermostat

ERV-24. Technician Settings & Operating Manual. Protected by one or more of the following patents: US 5,547,017; 5,881,806; 6,431,268; CA 2,245,135

Operator: Save these instructions for future use!

INSTALLATION & OPERATION MANUAL

Installation Instructions

T8600D Chronotherm IV Deluxe Programmable Thermostats

1F80ST /2 Day 5/1/1 Day Non-Programmable 1F86ST-0471

T8611M Deluxe Programmable Heat Pump Thermostats

6 Setting Your Program Schedule 7 Operating Your Thermostat 8 Additional Operation Features 9 Thermostat Maintenance

Programmable Load Management Thermostat

Installation guide. iheat thermostat. TB7100A1000 MultiPRO TM multispeed and multipurpose thermostat

tcu.z Commercial Programmable Thermostat Installation Instructions

QUICK INSTALLATION GUIDE

REMOVING OLD THERMOSTAT DETAILS. Model No CONTENTS YOUR THERMOSTAT REPLACES 0 PREPARATIONS. 5/2 Day Programmable Thermostat

T7100D Microelectronic Conventional Thermostat

6 Setting Your Program Schedule 7 Operating Your Thermostat 8 Additional Operation Features 9 Thermostat Maintenance

1F Non-Programmable 5/1/1 Day 7 Day

Operator: Save these instructions for future use

Detailed Installer Guide

Deluxe Programmable Thermostats

Deluxe Programmable Heat Pump Thermostat T8611M

WARNING Important Safety Information

Installation Settings Guide

Transcription:

Troubleshooting Poor Temperature Regulation This page lists problems that may affect the temperature performance of your LUX thermostat with suggested resolutions. For more detailed information please refer to the instructions that came with your thermostat. Model Problem No fan function in heat mode Fan ON continuously Indicates incorrect room temperature No second stage or AUX heating How do I set my thermostat to act as a manual thermostat? How do I remove the programming? Emergency heat does not turn on Heats or cools more than 5 degrees past its displayed set temperature TX500U Resolution Move the switch or jumper on the circuit board to its ELECTRIC POSITION for electric heat, then confirm with Fan Test below. Move Fan switch from ON to Auto. Remove the "G" wire. If fan continues to run, then either the system is mis-wired, or the problem is in the system, not the thermostat. Refer to thermostat manual to verify that your set temperature is what you expect it to be. The set temperature is always visible with "SET" on the display. Refer to your thermostats manual for calibration. Use this feature to adjust the displayed temperature up to +5 F(3 C) or -5 F(3 C) degrees. The offset may be set to 0. This needs to be set to at least 1. Refer to the WIRING section to verify that it is wired correctly. Different versions (a, b, c revisions) of this model have different ways to change setup options. Some are DIP switches on the circuit board and some are set using the front panel buttons in a menu. Refer to the user manual for your particular version for option settings. Must be set from Furn to HP. Different versions (a, b, c revisions) of this model have different ways to change setup options. Some are DIP switches on the circuit board and some are set using the front panel buttons in a menu. Refer to the user manual for your particular version for option settings. Remove thermostat body from the wall, leave the back plate in place. Verify that heating and cooling switch off within a few minutes. Replace the unit's batteries with fresh Duracell or Energizer alkaline batteries. Set unit to heat mode. Adjust set temperature to at least 5 degrees below room Then

No heat or cooling when expected adjust set temperature upward one degree at a time. Listen carefully for a soft click from the thermostat. This click should be heard near room Refer to your unit's manual to decrease the units swing setting to a narrower setting. Verify that your unit's placement and mounting are optimum per the installation section of its manual. Refer to the wiring troubleshooting guide to verify that your thermostat is wired correctly. Insure you are using the correct wiring diagram for your heating/cooling system. Note that in Cool Mode the thermostat may not activate a cooling stage until its compressor protection time has elapsed this may be a long as 5 minutes. Where the wires are coming out of the wall fill the hole with non-combustible insulation or putty to prevent drafts from affecting the thermostats performance. Move the switch or jumper on the circuit board to its ELECTRIC POSITION for electric heat, then confirm with Fan Test below. Different versions (a, b, c revisions) of this model have different ways to change setup options. Some are DIP switches on the circuit board and some are set using the front panel buttons in a menu. Refer to the user manual for your particular version for option settings. Refer to the thermostat manual to verify that your set temperature is what you expect it to be. The set temperature is always visible with "SET" on the display. Replace the batteries with fresh Duracell or Energizer alkaline batteries. Press HW_RST on the back of the thermostat. It may be necessary to reconfigure some settings after a reset. Set unit to heat mode. Adjust set temperature to at least 5 degrees below room Then adjust set temperature upward one degree at a time. Listen carefully for a soft click from the thermostat. This click should be heard near room Adjust set temperature down one degree at a time. Again listen carefully for a soft click from the thermostat near room Refer to wiring to verify that it is wired correctly for your system.

Fan Test Heat Test Cooling Test Heat Pump Test Thermostat Emergency Heat Test If your system is a low voltage system having 24VAC or less, and you are technically inclined, you may jump terminals as given below out to detect a malfunction in your system. With the power ON at the fuse box, touch the "G" wire to the "RH" terminal. The fan should come on immediately and stay on. The rush of air is usually heard. If the fan does not come on it is an indication that there is a problem with your system. Check any breaker or fuses that feed the 24VAC transformer that powers your system. To test gas or oil heating systems, take the "W1" wire off its terminal. With the power ON at the fuse box, touch the "W1" wire to the "RH" terminal for a couple of minutes and the heater should come on and stay on until the wire is removed. To test cooling, remove the "G" and "Y" wires. Connect them together with the "RC" for several minutes to observe operation. The system should come on and stay on. If the cooling fails to come on, or comes on and off, the problem is in the system. To test a heat pump system with an "O" wire, three wires must be connected together with the power terminal. The power terminal is "RH". With the power ON at the fuse box, connect the "O" and "Y", and "G" wires to the "RH" terminal for a couple of minutes and the unit should provide cool air. Wait at least 5 minutes and repeat this test without the "O" wire. The unit should provide heat. To test a heat pump system with a "B" wire, three wires must be connected together with the power terminal. The power terminal is "RH". With the power ON at the fuse box, connect the "B" and "Y" and "G" wires to the "RH" terminal for a couple of minutes and the unit should provide warm air. Wait at least 5 minutes and repeat this test without the "B" wire. The unit should provide cool air. 1. Set unit to EMER (heat) mode. 2. Adjust set temperature to at least 5 degrees below the room 3. Adjust set temperature upward one degree at a time. Wait for the Set temperature to be accepted and replaced by the room Listen carefully for a soft click from the thermostat. AUX will appear; and HEAT will flash when on.

For further assistance: 4. Repeat step 3 until the click is heard or the set temperature is at least 1 degrees above the room Remember to wait for the Set Temperature to be accepted and replaced by the room temperature before, before making the next adjustment. The click should be heard near room 5. After the click is heard, adjust set temperature downward one degree at a time. Again listen for a soft click from the thermostat. 6. Repeat step 5 until a click is heard or the set temperature is again 1 degree below the room 7. Steps 2 through 6 may be repeated to be sure that a click is heard each time the set temperature passes the room 8. If no click can be heard the thermostat is not operating properly. It must not be used to control a HVAC system until the problem is remedied. Contact your HVAC service company or our Technical Assistance Line if not resolved. Wiring Information and Troubleshooting This page provides general guidance for wiring your LUX 24VAC electronic thermostat. For more detailed information please refer to the instructions that came with your thermostat. Please make specific note regarding LOW VOLTAGE and LINE VOLTAGE directions. Do not install LINE VOLTAGE wires to a LOW VOLTAGE control. Improper installation of a "C" wire may cause damage to your system. Do no install a wire labeled "TC" from the previous thermostat to any of our controls. Installation of a "TC" wire may cause damage to your system. Do NOT wire by color of the wire, wire by the LETTER designation to which the wire was attached on the previous control. If there were no letter designations on your old thermostat, contact our Technical Assistance Department for assistance. Model Problem ALL If unsure how to connect your current wires Two wires control a heat only TX500U Resolution Never connect a low voltage thermostat to line voltage. Contact our Technical Assistance Line or your HVAC service company. Connect one wire to W1 and the other to RH leaving

system Two wires control a cool only system Two wires control heating AND cooling. Three wires for forced air heat only system, where the previous thermostat did not have a clock or timer Three wires for a heat only, forced water system that did NOT have a clock or timer Three wires control heating and cooling. One wire operates heat, one operates cooling and the third provides 24 VAC Three wires control a cooling only system. One wire operates the compressor, one operates the fan and the third provides 24 VAC Four wires control a heating and cooling, electric, gas or oil, forced air system that is NOT a heat pump Four wires control a Single Stage Heat Pump. They were labeled: G, Y, R or RH or RC, and either B or O was used Six or seven wires control a Heat Pump with an auxiliary heat stage. They were labeled: in the factory installed jumper wire between RH and RC. Connect one wire to RC leaving in the factory installed jumper wire between RH and RC and the other to Y. Currently no Lux controls are compatible with this system. The previous RH or RC wire is the 24-volt transformer wire. Connect it to RH. Leave jumper connecting RH to RC. Connect the forced air heat system to W1, and the fan wire to G. This system has a 3 wire zone valve. Connect the 24-volt power wire (usually R or RH) to RH and leave the factory installed jumper wire connecting RH to RC in place, the "valve close" wire to the A terminal and the "valve open" wire to the W1 terminal. The A terminal is powered on at all times when heat is not on. Connect the 24-volt power wire to RH. Install a jumper connecting RH to RC. This jumper is usually pre-wired. Connect the heat wire to W1, and the cooling wire to Y. Connect the 24-volt power wire to RC. Connect the cooling wire to Y and the fan wire to G. Connect the 24 VAC transformer wire to RH or RC. Install a jumper connecting RH to RC this jumper is often prewired. Connect the heat wire to W1, the cooling wire to Y and the fan wire to G. Do not connect wires to both B and O. Connect the reversing valve wire to B or O, just as the previous thermostat. Install a jumper wire from RH to RC if a jumper wire was not preinstalled. Connect the 24 VAC wire to RH. Install a second jumper wire from W1 to Y. Connect compressor wire to Y and the fan wire to G. Move dip switch #1 located on the back of the thermostat to the ON position. Set the GAS/ELECTRIC switch on the back of the thermostat to the ELECTRIC position. Once both of these changes have been made be sure to press the HW_RST button. Do not connect wires to both B and O. Connect the reversing valve wire to O or B, just as the previous thermostat. Connect 24 VAC wire to RH and leave

G, Y, R or RH or RC, and W or W2. Either B or O was used. And Emergency wire E is present For further assistance: in the factory supplied jumper wire between RH and RC. Connect compressor wire to Y and fan wire to G. It is not necessary to wire the E or X2 terminal. Connect W or W2 to the W2 terminal and add a jumper wire from W1 to Y. If you have a C (common wire) connect it to the C terminal. Move dip switch #1 located on the back of the thermostat to the ON position. Set the GAS/ELECTRIC switch on the back of the thermostat to the ELECTRIC position. Once both of these changes have been made be sure to press the HW_RST button. Contact your HVAC service company or our Technical Assistance Line if not resolved. Troubleshooting the Display Problems that may be identified from the display of your programmable thermostat are listed here with suggested resolutions. For more detailed information please refer to the instructions that came with your thermostat. Model TX500U Problem Display will not change Resolution Peel protective plastic label from display. Display blurred and unreadable Peel protective plastic label from display. Blank or fading display Display is locked or will not respond Displays reads "LO BATT" Press the small round HW_RESET button on the rear of your unit Replace thermostat batteries with fresh AA size Duracell or Energizer alkaline batteries. Be sure that they are installed with their polarity (+ and -) correct. Clean battery contacts with a pencil eraser and pry out the spring contact slightly to insure a clean, firm connection. Press the small round HW_RESET button on the rear of your unit Press the NEXT button 3 times then press the HOLD button once. This button sequence locks and unlocks the thermostat. Replace thermostat batteries with fresh AA size Duracell or Energizer alkaline batteries. Be sure that they are installed with their polarity (+ and -) correct. Clean battery contacts with a pencil eraser and pry out the spring contact slightly to insure a clean, firm

Display reads "STG. 2" or "AUX" How do I set my thermostat to act as a manual thermostat? How do I remove the programming? Display reads "OVERRIDE" What is the EMER button Displays wrong room You want to change the displayed temperature scale from F to C or from C to F Shows "8888" on display Shows "HI" or "LO" For further assistance: connection. "STG. 2" is displayed when the thermostat is turning on the first and second stages of a conventional heating system. "AUX" is displayed when the thermostat is turning on the first and auxiliary heating stages on a heat pump. Different versions (a, b, c revisions) of this model have different ways to change setup options. Some are DIP switches on the circuit board and some are set using the front panel buttons in a menu. Refer to the user manual for your particular version for option settings. "Override" appears on the display when the set temp is raised or lowered from the program Overrides are terminated at the next scheduled program period when the unit will revert to the program temperature and the "Override" indicator will be extinguished. The EMER setting is used with heat pump systems that have an emergency heat heating element. This feature disables the heat pump and allows only the emergency heat feature to operate. See Temperature Regulation. Different versions (a, b, c revisions) of this model have different ways to change setup options. Some are DIP switches on the circuit board and some are set using the front panel buttons in a menu. Refer to the user manual for your particular version for option settings. Slide the SET switch to DAY/TIME; then set the day and time. This means Out of Limit. The sensor is reading outside the thermostats display limit. Room temperature will reappear when the temperature returns to normal range. If actual room temp is not below freezing or above 99F/32C degrees, there may be a malfunction. Press the HW RESET button on the circuit board to reset. Contact your HVAC service company or our Technical Assistance Line if not resolved.