HOW TO MAINTAIN FOUNTAINS:

Similar documents
CAST STONE COLLECTION

c=) MODEL: NSD10037 PACKING DIAGRAM UMP AND (3) SHIMS ' IGHTS AND TRANSFORMER. LOWER COLUMN ESERVOIR BASE CASTING POLYFOA

CAST STONE COLLECTION

MODEL: NSD10020 PACKING DIAGRAM \ _\ CARDBOARD (2) CORD COVERS AND PART--+- i----1 :ASTING POLYFOAM UMP. c=j-transformer AND L_J LIGHT

ACIDS & ACID CLEANERS

CAST STONE COLLECTION

Installation Guide for the 2x2

GRANITE COMPOSITE SINK

Fleck 5600 Carbon Filter Installation & Start Up Guide

CAST STONE COLLECTION

en-us Use and Care Manual, Installation Instructions Washer WAT28400UC

Two Tier Illumifalls Patio Pond

Model K 520 M Part No

SAFETY, OPERATION AND MAINTENANCE MANUAL. MX-1408 SELF-CONTAINED EXTRACTOR This unit is intended for commercial use.

SAFETY AND OPERATING MANUAL

Unpacking and removing shipping bolts. Connecting the drain line Leveling the washer Connecting to the power supply

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

IMPORTANT SAFETY INSTRUCTIONS WARNING: When using electric appliances, basic

K 2.90 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS

SimplyClear Pressurized Filter Product Manual

PolyMax H2-24 Dutch Bucket System

POOL WINTERIZING INSTRUCTIONS

Clean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions?

Disappearing Fountains

CARE AND MAINTENANCE OF PRAVOL DURA-SHIELD COMPOSITE DECK BOARDS

CLEAN WATER PUMP. MODEL No: Hippo4A OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

Energy-Free Waterers SF-2C, SF-4C, EF-2C, EF-4C

Vacuum-ultraviolet Ozone Systems. Installation & Operation Manual. Model OZ-SPA

5700-E Sediment Filter Installation & Start-Up Guide

MLT100 Mirror Waterfall Fountain Bronze

Model:CH601. Warm & Cool Mist Humidifier. User Manual

SAFETY OPERATION & MAINTENANCE MANUAL X-405 CARPET EXTRACTOR This unit is intended for commercial use.

AllClear G2 Series Pressurized Filters Product Manual

PZ2 Series Manual. PROZONE INTERNATIONAL, Inc. Ozone Water Purification Systems. INSTALLATION GUIDE and OPERATION MANUAL. Prozone PZ2 Series

GENERAL CLEANING AND MAINTENANCE FOR ELEVATOR INTERIORS.

Because you re not like everyone else. MISTING FAN MF18W OWNER S MANUAL

Owner s. 18 Misting MF18W. To view

SUS-12 Steam Cleaner User Manual

AquaStream. ½ HP Floating Fountain. Please Keep for Your Records. Model #AS05 6A, 120V/60Hz Owner s Manual UNIT IDENTIFICATION

7800 Neutralizer Installation & Start-Up Guide

18 MaxxAir Portable Evaporative Cooler Owner s Manual This Manual covers the EC18DVS MaxxAir Portable Evaporative Cooler.

WINTERIZATION INDUSTRY BEST PRACTICE

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

STONETECH Maintenance & Care Porcelain, Ceramic & Quarry Tile with Cement Grout

3/4.8 AERODYNE 3/4.8L CLASS FIVE+

SAFETY OPERATION & MAINTENANCE MANUAL X-612 CARPET EXTRACTOR

Stainless Steel Kitchen Sink

Pavers Spade, rake (metal prongs), wheelbarrow, wooden stakes, string line, tape measure, pegs and spirit level

SolidFlo G2 Solid Handling Pumps Product Manual

Model K 3000 G Part No

K 3.97 M. Specifications or visit our website: In USA call: Part No

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA

Diamond Whirlpool/Air pool INSTALLATION & OPERATION INSTRUCTION

K 2.97 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS

SAFETY INFORMATION GO TO VAPAMORE.COM TO SEE THE MR-1000 FORZA INSTRUCTIONAL VIDEO

SAFETY INFORMATION WHEN USING THE STEAM CLEANER, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING. around water.

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA

Clean Water Made Easy

Model K 240 plus Part No

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

K Specifications. Max. Water Volume

There are certain common-sense steps that should be taken to protect your sculpture and ensure its longevity.

48 MaxxAir Portable Evaporative Cooler Owner s Manual

Pool Weasel Vacuum Users Guide

Operations and Safety Manual

ClearSpring Mini. Waterfall Filter. IMPORTANT SAFETY INSTRUCTIONS ClearSpring Mini (Item #110572) 5-YEAR WARRANTY.

Model K 5800 G Part No

AquaBlox Water Matrix

ACRYLIC PEDESTAL TUB

PolyMax H1-10 Dutch Bucket System

T1 SCRUBBER DRYER OPERATOR MANUAL

PRE-ASSEMBLED RADIANT CONTROL PANEL INSTALLATION MANUAL

OWNER S MANUAL WASHING MACHINE

Steam Mop with Foldable Handle 1500W

SUBCOURSE EDITION EN US ARMY ENGINEER SCHOOL PLUMBING FIXTURES (PLUMBING IV)

MANUAL PX4 ENGLISH. Nimbus Combi NIMC-90N NIMC-105N NIMC-120N Super Nimbus Combi ELECTRIC SAUNA HEATER / STEAM GENERATOR

INSTALLATION AND OPERATION. -, 3. -is INSTRUCTIONS FOR COOLAIR S EVAP-PAD COOLING SYSTEM. Coo/ah AMERICAN COOLAIR CORPORATION

FLOW-THROUGH FURNACE HUMIDIFIER

SMALL PAVER PROJECT. Home Gardeners School March 19, Presented by Robert W. Bellek Owner

22 Water Fall Instructions

Model K 330 M Part No

J-PRO V 230V Dual Voltage Chlorinator Installation & Start-Up Guide

SUBMERSIBLE WATER PUMPS

ProPet Washer. I-1020 Page 1 of 6 Rev. D /15/11

CWS Plus Sediment Filter Installation & Start Up Guide

HydroCycle Vertical Aeroponic Systems

All purpose Cleaner I. All-purpose Cleaner II. Drain Cleaner. 1 quart of warm water. clear water. 1 Tbsp. ammonia* 4 Tbsp.

How to Fix a Leaky Toilet:

Before using your machine, you must familiarize yourself with all of its components.

Instructions for installation and use English

User s Information Manual

Hoshizaki America, Inc.

INSTALLATION AND INSTRUCTION MANUAL

INSTRUCTION BOOKLET. Electric Steam Sterilizer

K Specifications. Max. Water Volume

PUDDLE PUMP PUDDLE PUMP. MODEL No: PSP125 OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

Owner s Manual FS-10/FreshSpa

SPIKA NG ICE MAKER MAINTENANCE

Ecosystem Pond Manual

Clean Water Made Easy. Fleck 7000 Tannin Filter Installation & Startup Guide. Questions?

Transcription:

HOW TO MAINTAIN FOUNTAINS: Thank you for your purchase of a fountain! In this care sheet you will find important information about installing and maintaining your fountain. Products are made with the upmost care and best materials possible. With proper care and maintenance, your fountain will last for years and generations to come. BASIC INFO: ~ Place fountains on a flat, solid base. Examples include: a concrete foundation, compacted gravel, or paver stones. Fountains need to be on a level surface to operate correctly. ~ Fountains with a large one-piece pond basin, (48 diameter and up) the basin must be placed on a soft surface like sand or gravel (not dirt). If a pond basin is to be installed on a hard surface like concrete or pavers, a 1-2 layer of sand must be applied over the surface. The sand will help with leveling by allowing the basin to settle and be completely supported, reducing the risk of possible stress cracks due to uneven support. Sand can be grouted after installation to prevent and run-off. ~Fountains do not require a permanent water line as fountains come with recirculating pumps. Fountains can be filled using a hose, bucket, etc. when needed. ~ You need to have electrical outlet in close range to the location of the fountain. Pumps have a three prong plug and the cord length is usually 12 ft long, so the outlet needs to be fairly close. Fountain pumps should only be plugged into a GFCI protected, outdoor outlet. ~ Water level must be full to the rim AT ALL TIMES (not doing so will cause the concrete to shock and crack). We not responsible for cracked items after delivery or pick up. ~During the winter months, protect your fountain from harsh or freezing weather by draining the fountain and covering it with a weather proof tarp, or dismantle it and store it indoors. This will protect your fountain from cracking and/or severe damage. ~ Never fill a bowl with water when it is hot to the touch (doing so will shock the concrete and crack). Fill the bowl in the early morning or at night when it is cool out. ~ Keep the water pump clear of leaves and debris so that it does not get clogged *Clean pump filter at least once a month, depending on the area the fountain is. In heavily wooded areas, the pump needs to be checked and cleaned more often. ~ If the fountain develops algae or build up, drain the water from the fountain and scrub off with a brush or soft carwash sponge. Try not to scrub too hard or vigorously. Doing so may cause the stain to come off. Rinse after algae is scrubbed off. *To prevent algae build up, use an algae reducer solution, such as Fountec or CrystalClear-Sparkle, to reduce any build up. Do not use Chlorine or any other pool chemicals! Chlorine and most pool chemicals will damage the fountain and pump. ~Hard water should be filtered before filling your fountain; you can use a hose-attached prefilter, such as the PreFresh Spa & Pool Water Fill Filter, available online or at a local swimming pool supply store. In areas with severe hard water, only distilled water should be used to fill your fountains. Filtering the water will not remove all mineral content in hard water, lime scale and white residue can still appear on your fountain, which should be removed immediately. ~Any white residue (white scale, lime scale, calcium buildup, or efflorescence) that builds up on the fountain should be removed immediately. This buildup is normal and unavoidable in areas with a high mineral content (hard water) in the local water supply. The best way to remove any white residue would be to gently scrub a mixture of Protec or (CrystalClear-SubLime) and water along the surface of the fountain. A mixture of 3 parts white vinegar and 1 part water will also work and removing any white residue. Failure to remove any white residue will stain and/or damage the fountain. Adding Protec or SubLime to the fountain s water will help in softening the hard water, regular use in accordance to the instructions is recommended. The manufacturer's warranty does not cover damage due to white scale, lime scale, calcium buildup, efflorescence, or freeze damage. Please thoroughly review this care sheet for more information. ~ Most fountains have no interlocking component parts. The component parts are held together by gravity only. Gluing or cementing the component parts together is not recommended. The parts may need to be dismantled to replace the pump, hardware, or to move the fountain to another location.

Steel Securing Bar Wall, Fence, or Post Eye Bolt Clear Vinyl Tubing PVC Threaded Elbow (back of fountain) Small Turn- Buckle Side View 3 prong power cord G-280 Pump Hard Surface. (See Step 2) Installation Instructions:1. Read the How to Maintain Fountains instruction sheet included with your shipment. (On reverse side) 2. Place base of fountain on a hard or solid surface, such as a conrete pad, pavers stones, bricks, or compacted pea gravel. Make sure base is level with the ground. If not level, place a shim under to level 3. Place basin on top of base and center. 4. Place pump in left compartment towards rear of basin. Drape pump cord over basin and run along back of base so it is not visible. 5. Connected clear vinyl tubing to nozzle on pump and secure. Temporarily drape tubing over back of bowl. 6. With two or more people, lift top component of fountain and place on top of basin as shown. To ensure that there is no damage, place burlap (used for packaging) around edges of basin. 7. Cut tubing to length and attach to PVC elbow on back of ftn. 8. Secure top of fountain to a wall, post, or fence using supplied turn-buckle and eyebolt. Turn buckle should attach to the steel bar towards the top and back of fountain. 9. Fill basin full of water and plug in pump. Adjust water flow using blue dial on front of the pump. 10. Enjoy your new fountain!

Step 5 Steel Bar (on back of ftn) used for securing fountain to wall, fence, or post. Steel wire recommended for securing Step 4 Clear Vinyl Tubing. Secure to copper connection G-280 Pump w/ water-flow adjustment knob. Step 2 Step 3 Slide power cord through rubber stopper and secure rubber stopper in the 2 PVC coupling. Check for tight fit to avoid leaks. 110V 3 prong power cord. Plug into 110v GFCI outdoor outlet. Turn blue knob to adjust water flow. Step 1 Hard Surface such as a concrete pad, compacted pea gravel, paver stones, or bricks

See Back for Fountain Care Instructions Cut 5 piece of PVC tubing and place in hole uder ball. Tubing should go inside hole on top of column Clear Vinyl Tubing Giannini adjustable pump. Turn blue nob to reach desired water flow. 110V 3 prong power cord. Plug into 110v GFCI outdoor outlet. Connect clear tubing to hole inside column. Tubing should extend only 2-4 inches inside column. Slide power cord through rubber stopper and secure rubber stopper in the 2 PVC coupling. Check for tight fit to avoid leaks. Hard Surface such as a concrete pad, compacted pea gravel, paver stones, or bricks. If surface is not exactly level, wood or plastic shims may be used to level founain.

Connect clear tubing to hole inside top fineal. Tubing should extend only 2-4 inches inside fineal. Clear Vinyl Tubing Adjustable pump. Turn blue nob to reach desired water flow. Place large bowl on large pedestal. With someone s help, tilt both the pedestal and bowl together (very slightly) to pull out pump cord from bottom of pedestal 110V 3 prong power cord. Plug into 110v GFCI outdoor outlet. Slide power cord through rubber stopper and secure rubber stopper in the 2 PVC coupling. Check for tight fit to avoid leaks. Hard Surface such as a concrete pad, compacted pea gravel, paver stones, or bricks. If surface is not exactly level, wood or plastic shims may be used to level founain.

Step 4 Place small support plate inside small bowl. Run tubing through hole into 1 PVC. Conect tubing to ball fineal. Tubing should extend 2-4 inside ball fineal. Clear Vinyl Tubing Step 3 Place medium support plate inside medium bowl. Run tubing through hole into 1 PVC. PVC Pipe to stop drainge of bowls when fountain turned off Step 2 Place large support plate inside large bowl. Run tubing through hole into 1 PVC. 110V 3 prong power cord. Plug into 110v GFCI outdoor outlet. Turn blue knob to adjust water Step 1 flow. Slide power cord through rubber stopper and secure rubber stopper in the 2 PVC coupling. Check for tight fit to avoid leaks. Hard Surface such as a concrete pad, compacted pea gravel, paver stones, or bricks

Clear Vinyl Tubing. Run throughout the center of fountain. 1/2 BarbxBarbxBarb Tee. Connect vinyl tubing as shown Secure 2 PVC Pipe (5-6 in Length) into PVC Coupling. This PVC pipe stops water from draining into pond when Fountain is off Slide power cord through rubber stopper and secure rubber stopper in the 2 PVC coupling. Check for tight fit to avoid leaks. Pump with 110V 3 prong power cord. Plug into 110v GFCI outdoor outlet. Turn blue knob to adjust water Hard Surface such as a concrete pad, compacted pea gravel, paver stones, or bricks. If surface is not exactly level, wood or plastic shims may be used to level founain.

Concrete Pad Diagram for #1108 Romana Coping, #1109 Tuscania Coping, & #1115 Sparta Coping 1 Threaded Pipe for Drainage 2 Coupling At Least 15 From Edge of Pad 2 PVC Pipe conduit for Electrical (Pump & Optional Lighting.) Use only only 90 Sweep Elbows Plug into GFCI Protected Outlets. Can also be hardwired by an electrician. 11-6 (138 ) 3-4 Thick

Concrete Pad Diagram for Classico Coping, Venice Coping, Regina Coping & Pietra Coping 1 Threaded Pipe for Drainage 2 Coupling At Least 15 From Edge of Pad 2 PVC Pipe conduit for Electrical (Pump & Optional Lighting.) Use only only 90 Sweep Elbows Plug into GFCI Protected Outlets. Can also be hardwired by an electrician 8 (96 ) Diameter 3-4 Thick

Concrete Pad Diagram for 1 Threaded Coupling for Drainage 2 Coupling At Least 15 From Edge of Pad 2 PVC Pipe conduit for Electrical (Pump & Optional Lighting.) Use only only 90 Sweep Elbows. Plug into GFCI Protected Outlets. Can also be hardwired an Electrician. 11-2 (134 ) 3-4 Thick

Concrete Pad Diagram for Viginti Pond Coping 52.5 1 Threaded Coupling for Drainage Pump 2 Coupling At Least 30 From Edge of Pad 125 125 Electrical Cord for Lights (Optional) 2 PVC Pipe conduit for Electrical (Pump & Optional Lighting.) Use only only 90 Sweep Elbows Plug into 110v GFCI Protected Outlets. Can also be hardwired by an electrician Concrete Pad Thickness: 3-4