Q Model AuCS A Accessory

Similar documents
Marine Q 1300 Ice Machine

Service Manual Q MODEL DISPENSER Q160/290/300

S1800M Model Ice Machines. Installation Use and Care Manual

Manitowoc. UG Series Ice Machines. Installation, Use & Care Manual

Undercounter Ice Machines

Undercounter Ice Machines

Owner / Operator Use and Care Guide I SERIES 224 ICE CUBE MACHINE

Ice Machines J Model Service Manual

ES60 UnderCounter Model Ice Machines. Installation, Use & Care Manual

iaucs Automatic Cleaning System Installation, Operation and Maintenance Manual Original Document

QM45 UnderCounter Model Ice Machines. Installation, Use & Care Manual

Installation Use and Care

Q130/Q210/Q270 Series Ice Machines

Manitowoc. QF0400 Model Flake Ice Machine. Installation, Use & Care Manual

UG Series Ice Machine

S Model Ice Machines

Q210/Q270 Undercounter Ice Machines

Part Number STH045 8/15

Part Number STH045 3/14

Indigo Series. QuietQube Ice Machine. Technician s Handbook. Part Number STH026 6/15

UnderCounter Ice Machines

INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO-200/250

Undercounter Ice Machines. Technician s Handbook

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

Reach-In Refrigerators and Freezers Service Manual

KOOLAIRE Ice Machines

VANTAGE. Installation Manual. Release Date: April 16, 2003 Publication Number: INS Revision Date: January 22, 2015 Revision: E

MIGHTY PRO 1/4 HP CHILLER

Viking Use & Care Manual

Hoshizaki America, Inc.

MODULAR CRESCENT CUBER

EC S 040 A. Installation Instructions 1-1. General Information. Model Numbers. Model Numbers Identification. This manual covers the following models:

Service Manual Models CPH2 & CPH3

Installation Manual CARBONATOR With Plain-Water Booster

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

SELF-CONTAINED FLAKER

Beverage Ice Chests DB, DBC, FB, FBC, 1522 & 2123

Undercounter Ice Machines. Technician s Handbook

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

INSTRUCTION MANUAL BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

OWNERS MANUAL For IN ROOM BREWING SYSTEM MODEL REFILLABLE CAPSULES K901. Includes: Installation Use & Care Servicing Instructions

INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO VALVE

ICE DISPENSER. Installation/Service Manual

Flake & Nugget Machines RFF/UFF/RNF/UNF Models Technician s Handbook

Hoshizaki America, Inc.

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

Manitowoc. Indigo Series Ice Machines With R290 Refrigerant. Technician s Handbook

Frosty Factory of America, Inc.

ICE DISPENSER. D45 and D90 Installation Manual. Release Date: August, 1995 Publication Number: Revision Date: March 27, 2014 Revision: D

Installation, Operation and Maintenance Manual

SERVICE/INSTALLATION MANUAL ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250

INSTALLATION AND OPERATING MANUAL

INSTRUCTION MANUAL BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

PROAIR Air Conditioner. CR43 Model INSTRUCTION MANUAL nvent Rev. H P/N

InstructIon Manual KrEs EQuIPMEnt stands

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

Reliability is a beautiful thing TM MODULAR FLAKER F-800MAH(-C) F-800MWH(-C) INSTRUCTION MANUAL

PRECISION PRECISION. Installation and Operating Instructions FLOW. AUTOMATIC REGULATOR

Hoshizaki America, Inc.

BLG-HGP Model Bottom Mounted Full-Length Swing Glass Door Freezer Merchandisers

Eclipse Technical Training CME686 CME810 CP686 CP886 CP1086

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

SAVE THESE INSTRUCTIONS HOUSEHOLD USE ONLY

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

Hoshizaki America, Inc.

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

MAXUM 5 5 Gallon Box Extractor

KM-900MAH KM-900MWH KM-900MRH KM-900MRH3

T-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N

Instruction Manual. Bucket Oil Pump

For more Parts Information:

Operation and Maintenance Manual

RecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual

Ui REFRIGERATOR SPEC SHEET

ISSUED: FEB. 23, 1998 REVISED: OCT. 15, 1999 HOSHIZAKI MODULAR FLAKER MODEL F-450MAF(-C)

Technical Training Prodigy Undercounter Cubers. Models CU1526, CU2026 and CU3030

Installation & Operation Manual Ice Cream Freezers

CH250 AND CH251 CHILLERS

Xaact Spot. Xaact Hot Spot

Hoshizaki America, Inc.

ADVANTAGE SERIES KXRP28 AIR-TO-AIR HEAT EXCHANGER

UNDERCOUNTER DISHWASHER

INSTALLATION & OPERATING INSTRUCTIONS MODEL #17900 KEGERATOR MANUAL

VP17A BUNN OPERATING & SERVICE MANUAL

T-Series Air Conditioner T15 Model


IMPORTANT INFORMATION - PLEASE READ CAREFULLY

MIM-500FA, MIM-650FA, MIM-900FA, MIM-1000FA

Electric Mini Tank Water Heaters ME10 ME25 ME40 ME60

V-SERIES Air Conditioner. VA08 Model INSTRUCTION MANUAL nvent Rev. F P/N

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers

AUC Cell Washer. User Manual

CUBE ICEMAKER MODELS SCU25, SCU35, SCU45, SCU75, SCU95, SCU120 INSTALLATION AND SERVICE MANUAL VERSION 2

Hoshizaki America, Inc.

Installation & Service Manual

Rules for Safe Operation

Hoshizaki America, Inc.

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532

KML-600MAH KML-600MWH KML-600MRH

Transcription:

Q Model AuCS A Accessory (Automatic Cleaning System) Installation Use and Care Manual This Manual Covers Installation, Use and Care Information for the AuCS A Accessory. We reserve the right to make product improvements at any time. Specifications and design are subject to change without notice. Part Number 80-1218-3

Safety Notices When installing or using the AuCS A accessory, be sure to pay close attention to the safety notices in this manual. Disregarding the notices may lead to serious injury and/or damage to the ice machine or AuCS accessory. Throughout this manual, you will see the following types of safety notices: WARNING Text in a Warning box alerts you to a potential personal injury situation. Be sure to read the Warning statement, and then proceed carefully. Text in a Caution box alerts you to a situation in which you could damage the ice machine or AuCS accessory. Be sure to read the Caution statement, and then proceed carefully. Procedural Notices When installing or using the Model AuCS A accessory, be sure to read the procedural notices in this manual. These notices supply helpful and important information. Throughout this manual, you will see the following types of procedural notices: Important Important boxes serve two functions: They call the operator s attention to important information. They also provide the service technician with information that may help in performing a procedure more efficiently. Disregarding this information may slow down the work. NOTE: Text set off as a Note provides you with simple, but useful, extra information. Use only Manitowoc approved Ice Machine Cleaner (part number 94-0546-3) and Sanitizer (part number 94-0565-3) with the AuCS accessory. Read and understand all information printed on the bottles before use.

Table of Contents Section 1 - General Information Table of Contents Freight Damage and Claims Procedure...1-1 Model/Serial Number Location...1-1 Owner Warranty Registration Card...1-2 Warranty Coverage...1-2 Component Location and Identification...1-3 Compatible Ice Machine Models...1-4 Section 2 - Installation Instructions General...2-1 Electrical Service...2-1 Location/Mounting...2-2 Connection to Ice Machine...2-4 Determine Type of Solution Needed...2-12 Installing Bottle of Solution...2-12 Changing Solution Type...2-13 Hose Priming...2-13 Setting Frequency of Cleaning...2-14 Removal From Service/Winterization...2-14 Section 3 - Operation Automatic Operation...3-1 Manual Start Operation Q Models...3-1 QDUAL...3-3 Changing Switch Position During Automatic Operation Q Models...3-2 Q1400C...3-2 QDUAL... 3-3 i

Table of Contents THIS PAGE INTENTIONALLY LEFT BLANK ii

Section 1 General Information Section 1 General Information Freight Damage and Claims Procedures 1. Shortages Check the number of cartons delivered against the quantity shown on your receipt. If the quantities do not match, have the driver note the shortage and file your claim with the freight company. 2. No-Fault Claim Procedure Manitowoc assumes responsibility for all freight damage claims involving participating carriers, with the following exceptions: When the trucking company loses the equipment. When fire destroys the equipment en route. When a traffic accident damages the shipment en route. 3. Visible Damage A. If a carton appears damaged in any way, open the carton and inspect the contents in the presence of the driver. Note the nature and extent of the damage on the freight bill. B. Notify your local Manitowoc distributor to inspect the merchandise within 15 days of delivery. Do not attempt to repair the damage. 4. Concealed Damage A. If damage is noticed at the time of installation, notify the distributor immediately and ask for an inspection. B. Do not destroy packing materials until the inspection is completed. These conditions must be met before your claim can be processed by the distributor. 5. Claims Manitowoc Ice, Inc. and your local distributor will arrange to repair or replace the equipment. Model/Serial Number Location Record the model and serial number of the AuCS A accessory in the space provided below. These numbers are required when requesting information from your local Manitowoc distributor, service representative, or Manitowoc Ice, Inc. The model and serial number are listed on the OWNER WARRANTY REGISTRATION CARD. They are also listed on the MODEL/SERIAL NUMBER DECAL affixed to the side of the AuCS A accessory. Model Number Serial Number Model Number Serial Number Model/Serial Number Location Ice Machine Remote Condenser or Condensing Unit MODEL AND SERIAL NUMBER PLATE SV1275 Bin/Dispenser AuCS A Accessory 1-1

General Information Section 1 Owner Warranty Registration Card GENERAL The packet containing this manual also includes warranty information. Warranty coverage begins the day your new AuCS A accessory is installed. Important Complete and mail the OWNER WARRANTY REGISTRATION CARD as soon as possible to validate the installation date. If you do not return your OWNER WARRANTY REGISTRATION CARD, Manitowoc will use the date of sale to the Manitowoc distributor as the first day of warranty coverage for your new AuCS A accessory. Warranty Coverage GENERAL The following Warranty outline is provided for your convenience. Contact your local Manitowoc representative or Manitowoc Ice, Inc. if you need further warranty information. PARTS Manitowoc warrants the AuCS A accessory against defects in materials and workmanship, under normal use and service for three (3) years from the date of original installation. LABOR Labor required to repair or replace defective components is covered for three (3) years from the date of original installation. EXCLUSIONS The following items are not included in the ice machine s warranty coverage: 1. Normal maintenance, adjustments and cleaning as outlined in this manual. 2. Repairs due to unauthorized modifications to the ice machine or the AuCS A accessory, or the use of non-standard parts without prior written approval from Manitowoc Ice, Inc. 3. Damage caused by improper installation of the ice machine, AuCS A accessory, electrical supply, water supply or drainage, or damage caused by floods, storms, or other acts of God. 4. Premium labor rates due to holidays, overtime, etc.; travel time; flat rate service call charges; mileage and miscellaneous tools and material charges not listed on the payment schedule. Additional labor charges resulting from the inaccessibility of the ice machine and AuCS A accessory are also excluded. 5. Parts or assemblies subjected to misuse, abuse, neglect or accidents. 6. Damage or problems caused by installation, cleaning and/or maintenance procedures inconsistent with the technical instructions provided in this manual. AUTHORIZED WARRANTY SERVICE To comply with the provisions of the warranty, a refrigeration service company, qualified and authorized by a Manitowoc distributor, or a Contracted Service Representative must perform the warranty repair. NOTE: If the dealer the ice machine and AuCS A accessory were purchased from is not authorized to perform warranty service, contact the Manitowoc distributor or Manitowoc Ice, Inc. for the name of the nearest authorized service representative. 1-2

Section 1 General Information Component Location and Identification MOUNTING SLOTS DISPENSING PUMP COMMUNICATION WIRE (9 FEET LONG) VINYL TUBE (9 FEET LONG) VINYL TUBE PLASTIC CAP CONTROL BOARD ELECTRIC POWER CORD (8 FEET LONG) PUMP OSCILLATING DIODE SV1630G COMMUNICATION CONNECTION QDUAL COMMUNICATION WIRE IS SUPPLIED WITH ICE MACHINE AND IS LOCATED ON THE BACK OF THE CONTROL BOX COMMUNICATION CONNECTION COMMUNICATION WIRE IS SUPPLIED WITH AUCS CLEANING FREQUENCY SELECTOR SWITCH RELAY ELECTRIC CORD TO DISPENSING PUMP ELECTRIC CORD FOR POWER TO AuCS PUMP OSCILLATING DIODE CONTROL BOARD SV3065 1-3

General Information Section 1 Compatible Ice Machine Models The AuCS A accessory can be used on all Manitowoc ice machines capable of accepting the AuCS accessory. Q Model Undercounter (Q130, Q210, Q270) QM model (QM20, QM30, QM45) and Flake Ice Machines (QF800, QC700, QF400) are not AuCS compatible. Listed models are compatible with the AuCS A accessory Q MODELS J MODELS Air, Water or Remote Condenser Air, Water or Remote Condenser B MODELS Air, Water or Remote Condenser B150 Q200 J200 B200 J250 B250 Q280 Q320 J320 B320 Q370 Q420 J420 B420 Q450 J450 B450 Q600 J600 B600 Q800 J800 B800 Q1000 J1000 B1000 Q1300 J1300 B1300 Q1600 Q1800 J1800 B1800 QUIETQUBE MODELS Q600C Q800C Q1000C Q1400C QDUALC ICE BEVERAGE MODELS IB600C IB800C IB1000C SU1000C (SerVend UC300 Dispenser) 1-4

Section 2 Installation Instructions Section 2 Installation Instructions General These instructions are provided to assist the qualified installer. Check your local yellow pages for the name of the nearest Manitowoc Ice Machine Distributor or call Manitowoc Ice, Inc. for information regarding installation and start-up services. WARNING Improper installation will affect dispensing rate. Install only within the parameters outlined in this installation manual. Please contact your local Manitowoc Distributor or call Manitowoc Ice, Inc. for assistance if you encounter a problem that is not covered by this manual. 12.12" 30.78 CM 3.43 " 8.7 CM 12 30.48 CM 9 274.3 CM Electrical Service WARNING All wiring must conform to local, state, and national codes. Voltage/Cycle/ Phase Runnin g Amps N.E.M.A Electrical Plug Configuration 115/60/1.3 5-15P 220/240/50/1.1 No plug attached 115 VOLT WIRING The 115/60/1 AuCS has an eight (8) foot cord which must be plugged into a 15 amp electrical outlet. Never use an extension cord. If an outlet is not in reach of the AuCS power cord, have an outlet installed. 220/240 VOLT WIRING The 220/240/50/1 AuCS can be wired to: The terminal block located in the ice machine. With a separate plug. To a separate disconnect. TERMINAL BLOCK LOCATED IN ICE MACHINE Dimensions 8 243 CM SV1632G PRE-WIRED TO ICE MACHINE L 1 N GROUND L 1 N GROUND TO SEPARATE FUSE/ CIRCUIT BREAKER. DISCONNECT ALL POLES. REFER TO ICE MACHINE INSTALLATION INSTRUCTIONS FOR FUSE RATING. N L 1 PRE-WIRED AT AuCS ACCESSORY 220/240/50/1 Wiring AuCS POWER CORD SV1633G 2-1

Installation Instructions Section 2 Location/Mounting Do not install in an area where the air temperature falls below 35 F or exceeds 110 F. The AuCS A must be protected if it will be subjected to temperatures below freezing. Refer to Removal From Service/Winterization. HEIGHT REQUIREMENT (Refer to drawing on page 2-3.) Either the base or the top of the AuCS A must be within 2 of the base of the ice machine. Do not mount the AuCS A too high or too low. The cleaner or sanitizer may siphon (or dispense improperly)into the ice machine water trough if the AuCS A is mounted too high or too low. DISTANCE REQUIREMENT (Refer to drawing on page 2-3.) The AuCS A must be mounted within 9 feet of the ice machine to accommodate the low voltage communication wire and tubing. The tubing may be shortened to accommodate a run of less than 9 feet. Do not extend the length of the 9-foot low voltage modular communication wire or tubing. The correct amount of solution will not dispense. FASTENING TO BIN OR DISPENSER 3. Align the AuCS A key slots with the mounting bracket tabs. Verify the tabs are at the top of the key slots and that the AuCS A is level. 4. Remove the backing from the adhesive bumpers (part D, page 2-4.) Attach bumpers to the mounting bracket directly above the AuCS A control box. This eliminates upward movement and stops the tabs from disengaging the key slots. BRACKET Mounting to Ice Machine GASKET FASTENING TO WALL The AuCS A is mounted to the wall using the two key slots in the back wall of the accessory. Screw fasteners (not supplied) must hold the entire weight of the AuCS A accessory (approximately 10 lb.). 6.56 16.6 CM BUMPER SV1640G The AuCS A accessory may be mounted to the bin or dispenser only when permitted by local electrical codes. NOTE: The ice machine s serviceability may be reduced when the AuCS A is mounted to the bin or dispenser. Wall mounting is recommended. 1. Set the mounting bracket (part F, page 2-4) over the bin top rail at desired location (refer to figure). 2. Remove the backing from the foam adhesive tape (part E, page 2-4). Apply tape to mounting bracket, and along the entire bin rail. Key Slot Dimensions SV1634G 2-2

Section 2 Installation Instructions BASE OF ICE MACHINE NO! TOO HIGH 2 5 CM 2 5 CM BOX BASE OR BOX TOP MUST BE WITHIN 2 (5 CM) OF ICE MACHINE BASE NO! TOO LOW NOTE: BOX MUST ALSO MOUNT WITHIN REACH OF 9 TUBING AND LOW VOLTAGE COMMUNICATION WIRE. Height and Distance Requirements SV1639G 2-3

Installation Instructions Section 2 Connection to Ice Machine GENERAL PVC CONDUIT FITTING (A) INSTALLATION A ½ PVC CONDUIT FITTING ½ LOCKNUT (C) B HOSE CLAMPS C LOCKNUT ½ PVC CONDUIT FITTING (A) D BUMPER PVC Conduit Fitting (A) Installation SV1636G 1. Insert the PVC fitting (A) into the AuCS A and tighten with the lock nut (C). Parts Identification E F FOAM TAPE BRACKET SV1635G WARNING Disconnect the electric power supply to the ice machine at the electrical disconnect before proceeding. 2. If required for access, remove the front, top, and right side panels from the ice machine. 3. Remove the 7/8 access hole plug located on the back of the corner post of the ice machine 4. Insert the PVC conduit fitting (Part A) and tighten with the lock nut (Part C). 2-4

Section 2 Installation Instructions Connection to Ice Machine (cont.) Q320 Q370 Q420 Q600C Q800C Q1000C Q200 Q280 Q450 Q600 Q800 Q1000 Q1300 Q1600 Q1800 1-1/8 DIAMETER ACCESS HOLE 1-1/8 DIAMETER ACCESS HOLE 5 3 1.5 1.5 ½ PVC CONDUIT FITTING (A) ½ LOCKNUT (C) ½ LOCKNUT (C) ½ PVC CONDUIT FITTING (A) SV1637G PVC Conduit Fitting (A) Installation 2-5

Installation Instructions Section 2 IB600C IB800C IB1000C Q1400C 1-1/8" DIAMETER ACCESS HOLE 1-1/8" DIAMETER ACCESS HOLE 5.9" 7.5" 2" 3.0" QDUAL 1-1/8" DIAMETER ACCESS HOLE 7.5" 2" 2-6

Section 2 Connection to Ice Machine (cont.) PVC CONDUIT CONNECTION (NOT SUPPLIED) Connect the ½ PVC conduit from the AuCS A to the ice machine. Install 1/2 conduit to protect the tubing and modular wire from damage or access. Installation Instructions NOTE: AuCS SHOWN IS 115 VOLT WITH POWER CORD ATTACHED NOTE: A pulling elbow is recommended for easier routing of the vinyl tubing and modular wire. SV1638G Typical PVC Conduit Installation 2-7

Installation Instructions Section 2 Connection to Ice Machine (cont.) WATER INLET VALVE ACCESS HOLE SV1641G WATER INLET BARBED FITTING WATER INLET BARBED FITTING Vinyl Tubing Installation (Typical 22 Ice Machine Shown) IB600C IB800C IB1000C SV3064 ROUTE TUBING SV1780 QDUAL WATER INLET BARBED FITTING ROUTE TUBING AND CONNECT TO 90 ELBOW Q1400C SV1770 RH 2-8

Section 2 Installation Instructions Q1400C ONLY A. 1/4" DIA x 4" LG VINYL TUBING B. 1/2" PVC CONDUIT FITTING (QTY 2) C. 90 THREADED ELBOW D. 1/4" FERRULE NUT E. 90 BARBED ELBOW A. Slide the 1/4" ferrule nut (part D) onto the 1/4" tubing (part A) B. Connect the 1/4" ferrule nut (with 1/4" tubing) to the 90 threaded elbow (part C) and hand tighten. C. Locate the 7/16" diameter hole in the bulkhead of the ice machine. (See illustration). D. Remove the plastic plug from the hole. E. Insert the threaded end of the barbed elbow (part E) into the hole. Screw the 90 threaded elbow (part C) to the barbed elbow (part E). Hand tighten. Be sure the threaded elbow (part C) outlet tube points downward, toward the water trough. F. 3/8" HOSE CLAMP (QTY 2) G. 1/2" LOCKNUT (QTY 2) 2-9

Installation Instructions Connection to Ice Machine (cont.) COMMUNICATION WIRE CONNECTION Insert the low voltage communication wire through the ½ conduit connecting the AuCS A to the ice machine. Section 2 Plug into the jacks on the ice machine control board and the AuCS A control board. (Refer to drawing for routing communication wire in ice machine.) CONTROL BOARD COMMUNICATION WIRE GROUND WIRE (Q1300/Q1800 ONLY) ROUTE WIRING THROUGH ACCESS HOLES AS SHOWN COMMUNICATION WIRE 30 AND 48 INCH 22 INCH SV1642G Low Voltage Communication Wire Connection QDUAL ONLY: The communication wire is attached to the rear of the ice machine control box. The communication wire included with the AuCS A is not used. AUCS CONTROL BOARD COMMUNICATION PORT QDUAL COMMUNICATION PORT 2-10

Section 2 Connection to Ice Machine (cont.) VINYL TUBING CONNECTION 1. Insert the tubing into the ½ conduit from the AuCS to the ice machine. 2. Slide the 3/8 hose clamp (B) onto the tubing and connect it to the barbed fitting on the AuCS dispenser pump. WATER INLET Installation Instructions AuCS INLET 3/8 HOSE CLAMP (B) 8 VINYL TUBING SV1644G MODULAR WIRE LEAD SV1643G Connecting Vinyl Tubing to Dispenser Pump Using 3/8 Hose Clamp (B) 3. Route the tubing through the bulkhead heyco fitting and into the water compartment. 4. Determine the amount of tubing required and cut off the excess. 5. Slide the 3/8 hose clamp (Part B) onto the tubing and connect it to the water inlet barbed fitting. Connecting Vinyl Tubing to Water Inlet Barbed Fitting AFTER INSTALLATION WARNING Read and understand this entire manual prior to operation of the AuCS A accessory. You must understand all warning and caution statements and follow all safety precautions to assure proper operation of the AuCS A accessory. 2-11

Installation Instructions Section 2 Determine Type Of Solution Needed Use only Manitowoc-approved Ice Machine Cleaner (part number 94-0546-3) or Sanitizer (part 94-0565-3) in the AuCS A It is a violation of Federal law to use these solutions in a manner inconsistent with their labeling. Read and understand all labels on the bottles before use. The AuCS A accessory will dispense Cleaner OR Sanitizer. It cannot dispense both at the same time. Do not mix Cleaner and Sanitizer solutions together. It is a violation of Federal law to use these products in a manner inconsistent with their labeling. MANITOWOC ICE MACHINE CLEANER Part Number 94-0546-3 Ice Machine Cleaner is used to control build-up and to remove lime scale or other mineral deposits. It will not sanitize the ice machine. It is recommended for use in places that have lime scale or other mineral deposits built up, but no problems with slime. MANITOWOC ICE MACHINE SANITIZER Part Number 94-0565-3 Ice Machine Sanitizer is used for sanitizing and controlling algae build-up (slime) and other bacterial growth. The ice machine should be sanitized on a regular schedule, following Manitowoc recommendations and local regulations. It is recommended for use in places such as pizzerias, bars, bakeries, etc., that have airborne bacteria (yeast). Sanitizing is also recommended in places that do not have lime scale (or other mineral deposit problems). Amount of Cleaner or Model Sanitizer Dispensed Q200 Q280 Q320 Q370 Q420 Q450 Q600 Q600C IB600C *2.4 ounces (70 ml) Q800 Q800C IB800C Q1000 Q1000C IB1000C SU1000C Q1400C Q1300 Q1600 Q1800 QDUAL *4.8 ounces (140 ml) *The dispense rate is automatically controlled Installing Bottle Of Solution WARNING Wear rubber gloves and safety goggles (and/or face shield) when handling Cleaner or Sanitizer. Follow instructions listed under Changing Solution Type on the next page when changing from Cleaner to Sanitizer or from Sanitizer to Cleaner. 1. Place the bottle into the AuCS A accessory. 2. Slide the tube to the bottom of the bottle and hand-tighten the cap. Bottle Installation TUBE MUST BE CLOSE TO BOTTLE BOTTOM SV1645 WARNING Do not use 1 gallon bottles of Cleaner or Sanitizer on the AuCS A 2-12

Section 2 Changing Solution Type Do not mix Cleaner and Sanitizer solutions together. It is a violation of Federal law to use these products in a manner inconsistent with their labeling. Use the following procedure to flush the system prior to changing from Cleaner to Sanitizer or from Sanitizer to Cleaner. 1. Remove the bottle of Cleaner or Sanitizer from the AuCS A. Insert a 16 oz. bottle of water. 2. Repeat the following until the water bottle is empty (approximately 8 times): A. Move the ice machine toggle switch to CLEAN. B. The water pump and dump valve will turn on. The dump valve will shut off after approximately 45 seconds. C. The pump will run for 60 seconds and then dispense for 10 seconds. (The Q1300, Q1600, Q1800 and QDUAL will dispense for 20 seconds). D. Move the switch to OFF after step C is completed. 3. Install a new bottle of either Cleaner or Sanitizer solution. Refer to Installing Bottle of Solution on previous page. Hose Priming Installation Instructions The dispenser pump requires priming only upon initial installation, or if the hose between the AuCS A and the ice machine has been pumped dry. WARNING Do not blow into or suck on the hose in an attempt to prime it. Do not prime the hose until installation is complete. Repeat the following procedure three times: 1. Move the ice machine toggle switch to CLEAN. 2. The water pump and dump valve will turn on. The dump valve will shut off after approximately 45 seconds. 3. The control waits until the water pump runs for 60 seconds, then energizes the AuCS A pump for 10 seconds. (The Q1300, Q1600, Q1800, and QDUAL will energize for 20 seconds). 4. Allow the ice machine to complete the cleaning or sanitizing cycle. Refer to Manual Start Operation for details. Important The priming procedure starts the automatic cleaning mode. Upon moving the ice machine toggle switch to ICE, the ice machine will run through 6 rinse cycles before making ice. 2-13

Installation Instructions Section 2 Setting Frequency Of Cleanings The AuCS A is factory-set to clean (or sanitize) the ice machine approximately once every two weeks. For less frequent cleaning, set the selector switch as indicated below. (Refer to Component Location and Identification for selector switch location.) Switch Time Between Position Cleanings 0 No cleaning (OFF) 1 Approximately 2 weeks (1120 harvests) 2 Approximately 4 weeks (2240 harvests) 3 Approximately 12 weeks (6720 harvests) NOTE: Switch positions 4-9 are inoperative. Do not use them. Important Using the AuCS A accessory is supplemental to regular cleaning and sanitizing (per Manitowoc recommendations and local regulations). Removal From Service/Winterization Leaving solutions in the AuCS A in freezing temperatures may result in severe damage to the dispensing pump. A failure of this nature is not covered by the warranty. If the AuCS A is to be removed from service for extended periods, or if it is to be exposed to ambient temperatures of 32 F (0 C) or below, follow this procedure: 1. Remove the Cleaning or Sanitizing solution bottle. 2. Follow the instructions under Hose Priming to pump all of the solution out of the dispensing pump and line. 2-14

Section 3 Ice Machine Operation Section 3 Ice Machine Operation Automatic Operation The following occurs when the toggle switch is in the ICE position: The ice machine control board counts the number of ice harvest cycles. The AuCS A accessory interrupts the ice making mode and starts the cleaning (or sanitizing) mode when the harvest count equals the Frequency of Cleaning setting of the AuCS A When the automatic cleaning (or sanitizing) cycle is complete (approximately 25 minutes, QDUAL 40 minutes), ice making resumes automatically, and the Harvest Count is reset to zero. Important Opening the curtain switch will interrupt the cleaning (or sanitizing) sequence. The sequence will resume from the point of interruption when the curtain re-closes. NOTE: The harvest count is reset after the AuCS A cycle is completed. It cannot be reset by unplugging the modular wire, changing the switch position, power loss, etc. Manual Start Operation (QDUAL SEE PAGE 3-3) Step 1 Set the toggle switch to the OFF position after ice falls from the evaporator at the end of a Harvest cycle. Or, set the switch to the OFF position and allow the ice to melt off the evaporator. Never use anything to force ice from the evaporator. Damage may result. Step 2 To start the automatic cleaning system, move the toggle switch to the CLEAN position. The water will flow through the water dump valve and down the drain. The Clean light will turn on to indicate the ice machine is in Clean Mode. The AuCS A pump energizes automatically to add cleaner or sanitizer to the ice machine. Step 3 The ice machine will automatically time out a ten minute cleaning or sanitizing cycle, followed by six rinse cycles, de-energize the Clean light and stop. This entire cycle lasts approximately 25 minutes. Step 4 After the cleaning or sanitizing cycle stops, move the toggle switch to the ICE position. Step 5 The ice machine may be set to start and finish a cleaning (or sanitizing) cycle, then automatically start ice making again. You must wait about one minute into the cleaning cycle (until water starts to flow over the evaporator), then move the toggle switch from CLEAN to ICE position. When the cleaning (or sanitizing) cycle is completed, an ice making sequence will start automatically. Important The Q1400C ice machine can not perform step 5. The toggle switch position must be changed from CLEAN to ICE after the AuCS A cycle has been completed. 3-1

Ice Machine Operation Section 3 Changing Switch Position During Automatic Operation Q MODELS/IB MODELS/SU1000C If the toggle switch is moved to OFF prior to the pump dispensing (less than 45 seconds into the cycle) then switched to: Q1400C If the toggle switch is moved to OFF prior to the pump dispensing (less than 45 seconds into the cycle) then switched to: ICE CLEAN A normal ice-making mode begins. A manual clean cycle begins. ICE CLEAN A normal ice-making mode begins. A manual clean cycle begins. (See Manual Start Operation, page 3-1.) (See Manual Start Operation, page 3-1.) If the toggle switch is moved to OFF after the pump dispenses (more than 45 seconds into the cycle, but before rinse cycles begin) then switched to: ICE CLEAN The clean portion of the cycle begins. After completion of the 10-minute Clean and 6 rinse cycles, the counter resets and a normal ice-making mode begins. A manual clean cycle begins. (See Manual Start Operation, page 3-1.) After completion of the 10-minute Clean and 6 rinse cycles, the counter resets and the ice machine awaits a change in the toggle switch position. If the toggle switch is moved to OFF after the 6 rinse cycles have begun and then switched from off to: ICE CLEAN The rinse portion of the cycle restarts and continues. After completion of the 6 additional rinse cycles, the counter resets and a normal ice-making mode begins. A manual clean cycle begins. (See Manual Start Operation.) After completion of the 10-minute Clean and 6 rinse cycles, the counter resets and the ice machine awaits a change in the toggle switch position. If the toggle switch is moved to OFF after the pump dispenses (more than 45 seconds into the cycle, but before rinse cycles begin) then switched to: ICE CLEAN The ice machine runs 6 rinse cycles, resets the counter and starts a normal icemaking mode. A manual clean cycle begins. (See Manual Start Operation ) After completion of the 10-minute Clean and 6 rinse cycles, the counter resets and the ice machine awaits a change in the toggle switch position. If the toggle switch is moved to OFF after the 6 rinse cycles have begun and then switched from off to: ICE CLEAN The ice machine runs 6 rinse cycles, resets the counter and starts a normal icemaking mode. A manual clean cycle begins. (See Manual Start Operation.) After completion of the 10-minute Clean and 6 rinse cycles, the counter resets and the ice machine awaits a change in the toggle switch position. Important After solution is dispensed (cleaner or sanitizer), the Q1400C ice machine must run 6 rinse cycles. Changing toggle switch position, disconnecting power, etc will not override the 6 rinse cycles. Each time the toggle switch is moved from Off to Ice (or power is interrupted), the six rinse cycles begin again. 3-2

Section 3 QDUAL ONLY Manual Start Operation Step 1 Set the toggle switch to the OFF position after ice falls from the evaporator at the end of a Harvest cycle. Or, set the switch to the OFF position and allow the ice to melt off the evaporator Never use anything to force ice from the evaporator. Damage may result. Step 2 To start the automatic cleaning system, move the toggle switch to the CLEAN position. The water will flow through the water dump valve and down the drain. The Clean light will energize to indicate the ice machine is in the Clean Cycle. Th ice machine will purge water for two minutes. The water fill valve will energize and remain energized until water contacts the water level probe. The AuCS A will then automatically add cleaner or sanitizer to the ice machine. Step 3 The ice machine will automatically time out a ten minute cleaning or sanitizing cycle, followed by six rinse cycles, de-energize the Clean light and stop. This entire cycle lasts approximately 40 minutes. Step 4 After the cleaning or sanitizing cycle stops, move the toggle switch to ICE position. Step 5 The ice machine may be set to start and finish a cleaning (or sanitizing) cycle, then automatically start ice making again. You must wait about 2 minutes into the cleaning cycle (until water starts to flow over the evaporator), then move the toggle switch from CLEAN to ICE position. After the fluid has been dispensed opening the curtain (bin switch) will interrupt the AuCS A sequence. The sequence resumes when the curtain closes. When the cleaning cycle (or sanitizing) is completed, an ice making sequence will start automatically. Ice Machine Operation Changing Switch Position During Automatic Operation If the toggle switch is moved to OFF prior to the pump dispensing (less than 2 minutes into the cycle) then switched to: ICE CLEAN A normal ice-making mode begins. A manual clean cycle begins. (See Manual Start Operation, page 3-1.) If the toggle switch is moved to OFF after the pump dispenses (more than 2 minutes into the cycle, but before rinse cycles begin) then switched to: ICE CLEAN The clean portion of the cycle begins. After completion of the 10-minute Clean and 6 rinse cycles, the counter resets and a normal ice-making mode begins. A manual clean cycle begins. (See Manual Start Operation, page 3-1.) After completion of the 10-minute Clean and 6 rinse cycles, the counter resets and the ice machine awaits a change in the toggle switch position. If the toggle switch is moved to OFF after the 6 rinse cycles have begun and then switched from off to: ICE CLEAN The rinse portion of the cycle restarts and continues. After completion of the 6 additional rinse cycles, the counter resets and a normal ice-making mode begins. A manual clean cycle begins. After completion of the 10-minute Clean and 6 rinse cycles, the counter resets and the ice machine awaits a change in the toggle switch position. 3-3

MANITOWOC ICE, INC. 2110 South 26th Street P.O. Box 1720 Manitowoc, WI 54221-1720 Phone: (920) 682-0161 Fax: (920) 683-7585 Web Site - www.manitowocice.com 2002 Manitowoc Ice, Inc.