VACUUM PUMP Micro Cartridge Pump

Similar documents
MULTI-STAGE, MULTI-FUNCTION AND MODULAR INTERMEDIATE VACUUM MODULES SERIES MI

VACUUM PUMPS VSM 진공펌프

MVG. Modular Vacuum Grippers. US5

Air. Pressure. Motion. nnnnnnnn

Self-regulating vacuum pumps. Characteristics. bar (Nl/s) Specifications

Vacuum generation Content

multi-stage vacuum generators - general information

Control unit PPT/RS,, Controls the functions of the conveyor. Fully pneumatic. The maximum recommended distance between the conveyor and contr

Vacuum generators VADM/VADMI

MMEngineering. Suction lifter. Lightning fast suction for lifting and moving. with only on vaccum line. Suction lifters Vacuum-operated

RA 2000 Series RA 15/6T & TB Conversion Valve

FIPA Vacuum Components

RA15/6T & TB Conversion Valve

REFRIGERANT SYSTEM SERVICE WARNINGS

5/12/2018 Climate Control System General Information and Diagnostics - Air Conditioning (A/C) System Recovery, Evacuation and Charging - G

PORTABLE DEW POINT MONITOR

SECTION 50 - CAB CLIMATE CONTROL

NT 27/1. Cartridge filter with float. Robust bumper

Premium Micro Desoldering station

Digital LEAD FREE. Soldering Soldering. Temperature range. Station. N1-06 Nozzle ø0.6 N1-08 Nozzle ø0.8 N1-10 Nozzle ø1.0 N1-13 Nozzle ø1.3. ø2.


Temperature control of individual floor-heated rooms or mixed floor-heating/radiator systems

HEATING AND AIR CONDITIONING

NT 27/1. Cartridge filter with float. Robust bumper. Robust metal latches

16. Hose Replacement. Disconnect power supply to the AR400.

Vacuum mixers Wamix-Classic and Wamix-Injector

Technical Datasheet. Suction Controllers, Flow Meters & Accessories

Vacuum related component model series variation

KIT-UR-V. IST-KIT-UR-V Page 1 of 12 REVISIONS DOCUMENT LAYOUT MOUNTING INSTRUCTIONS AND OPERATING MANUAL

AIRTERM DIRT AND AIRTERM MAG COMBINED SELF-CLEANING DIRT SEPARATORS / DEAERATORS

Premium Desoldering station with Electric Pump

Instruction Manual DIGITAL MANIFOLD FOR HVAC/R SYSTEMS

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A

Low air consumption vacuum generators

Wiring Transmitter and Detectors. mounting hole. A023a. mounting hole. A024a

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

8008 CIRCULATION UNIT FOR SOLAR THERMAL SYSTEMS, FLOW AND RETURN.

16 mm. Ionizer Nozzle type. Ion balance ±10 v. Slim design: Thickness dimension 16 mm RoHS compliant. Series IZN10

NT 35/1 Ap. ApClean (semi-automatic filter cleaning system) Practical cable storage compartment. Mobility and power

Productinformatie BAFA.NL BAFA.NL A.U.K. MÜLLER GMBH & CO. KG

VACUUM TECHNIQUE CATALOGUE 5.0 VACUUM A RESOURCE FOR EVERYONE. I N N O V A T I V E S O L U T I O N S I N V A C U U M T E C H N I Q U E

premium line Stations Different equipment designed for a specific soldering or rework job

Pressure Transducers Ultrahigh-Purity

VACUUM VALVES AND HOSES

The Safest Connections...

Self-regulating vacuum pumps. Characteristics. Ø max. vacuum air drawn in L2 model nozzle (%) Specifications. Curves: see page 9/27.

Phone: Fax :

SIHI Dry GD S Sizes S450, S650

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Oil & Gas. Features:

User manual Flushing device VAS 6337/1a

Characteristics. Ø nozzle. model

Introduction pisave optimize pisave onoff pisave release pisave sense pisave restrict...488

PD10. Serial Plates with Side Ports for ISO Valves. Technical Features. Technical Data. Functional Description. Page 1. Size 10 (D05) p max

Barrier Washer. Parts. Refer to Page 3 for Model Numbers. BAR17P_

New TERMOVAR Loading Unit. The link between bio-energy boiler and storage tank system

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:

Min Series. Modular Venturi Vacuum Pumps Min Series. Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off

Miniature Low Pressure Sensors. 24PC Series, Uncompensated/Unamplified 0.5 psi to 250 psi. Datasheet

HITACHI ROTARY COMPRESSOR MODEL SG153BG3GC I. SPECIFICATION. This specification is applied to SHANGHAI HITACHI rotary compressor. 2.

Measurement Solutions for Refrigeration Technology.

REFRIGERANT ON-VEHICLE INSPECTION AC 14

Measurement Solutions for Refrigeration Technology.

ACORE Filtration Co.,Ltd provides engineering,

Connectors for Optic Fibre Cable

Conveyors C. Conveyors C

INSTALLATION & MAINTENANCE

USER MANUAL UR500VAC UR480VAC UR500VAC-E UR480VAC-E UR500VAC-A UR500VAC-J AUTOMATIC DUST VACUUMS MODELS UNI-RAM CORPORATION ONTARIO CANADA

HNC-120BE-L/R-B HNC-150BE-L/R-B HNC-180BE-L/R-B HNC-210BE-L/R-B COUNTER SHOWCASE MODEL SERVICE MANUAL HOSHIZAKI

Vacuum suction nozzle OVEM-...-1P/1N

Air operated diaphragm pumps. Catalogue 2011 rev 1

Differential pressure gauge with electrical contact type Model: P650 series

Vehicle Level Heating and Air Conditioning Description and Operation A/C System - Manual. A/C System - Manual

INSTRUCTION MANUAL 4-WAY BALL VALVE Digital Manifold

User Manual. Single Diaphragm Dosing Pump SP-177. We set standards. Industriestrasse 56 FAX: FL-9491 Ruggell

Electronic flushing and pressure testing unit with oil-free compressor. REMS Multi-Push EN ZVSHK 1) DVGW 2) for Professionals

Desoldering Tool. New. Portable Desoldering Tool. Packing List. Specifications

1 L Rotary Vacuum Evaporator Instruction Manual

The DAUREX Quick Clean Pumps

Refrigerator. Installation Guide. Free Standing Appliance

Tri-Tech Medical Inc.

Installation & Maintenance Instructions KAPTIV ZERO AIR LOSS CONDENSATE DRAIN 04/08

Self-regulating vacuum pumps. Characteristics. Ø max. vacuum air drawn in L2 model nozzle (%) Specifications. Curves: see page 9/27.

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

SERVICE MANUAL CLASSIC PLUS 14

CERTUS 11 / 12 EVACUATION & REFRIGERANT CHARGING EQUIPMENT FOR FLAMMABLE GASES

Product overview Suction Guns, suction machines, Vac-Blast Cleaners

Complex Vacuum Generator realizing Stable and High-Speed Response Vacuum Generator VN Series

EDITION 5 R R ENGINEERS FIRST

NT 35/1 Ap. NT 35/1 Ap, ,

REFRIGERANT RECOVERY DEVICES AND ACCESSORIES

C 9000 Polymer Quick-Acting Safety Coupler Range

Installation Instructions for the MicroPressure Board Mount Pressure Sensors MPR Series Compact, High Accuracy, Compensated/Amplified

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

SERVICE MANUAL CLASSIC PLUS 14

SERVICE MANUAL OFFICE PRO 18

MEGA. cal electronic gas alarm. Installation, Operation, and Maintenance Instructions. Part No Rev. D Pg.

EL400 OPERATION MANUAL

SERVICE MANUAL MUH-A18WV - MUH-A24WV - MUH-A30WV - E1. Wireless type Models HFC

T a b l e o f C o n t e n t s

Pressure Sensors: Measurement Type: Gage, Vacuum Gage; Signal Conditioning: Unamplified; Pressure Range: ± 15.0 psi; Port Style: Straight

Transcription:

Pump Max. vacuum level : -85 kpa Max. flow rate : 6.5 NI/min Supply air pressure :.~.6 bar, max 7bar (43.5~87 psi, max 0.5 psi) Air consumption : 6.8~0.6 NI/min Supply air type : Dry compressed air Working temperature : - 0ºC ~ + 80ºC Noise level : 50 ~ 60dBA Feature Integrated with VMECA vacuum cartridge Low Energy consumption & Saving cost Compact (0mm) design with Light weight High vacuum level (Max. -85kPa) in low compressed air (~3bar) Modular system Quick response time & High flow Integrated with air control valve & vacuum release valve Push-in type direct hose fitting Easy to assemble & disassemble control valve unit Order No. MC 0 - M4 - A - PG 3 4 Model MC 0 - Micro cartridge VC0 3 Valves Air Supply Vacuum Release A (N.C. : Normal Closed) (N.C. : Normal Closed) B (N.C. : Normal Closed) - Body type S - Single unit M - Stack No mark - - Only CL type valve is available Remark : No mark is not available for Manifold type M4-4Stack 4 Vacuum Switch M6-6Stack No mark - Starndard (P)C - M8-3Pin Connector type M8-8Stack (P)G - LED wire type(3m lead wire) M0-0Stack Remark : (P) Output type : PNP open collector VCM8 4 : ㆍM8-3pin female connector ㆍAvailable for C or PC type 5 Sealing No mark - Starndard (NBR) V - Viton E - EPDM Specifications subject to change without notice.

Control Unit (for Micro Pump) Pressure range Mpa(kgf/cm²) : 0~0.7 (0~7) Inner shock / vabration (m/s²) : 300 / 50 Supply air type : Dry compressed air Working temperature : - 0ºC ~ + 80ºC electrical power consumption (W) Feature Integrated with VMECA vacuum cartridge Low Energy consumption & Saving cost Compact (0mm) design with Light weight : Standard - 0.85 (Lamp, rated voltage approval) Power saving mode - 0.45 High vacuum level (Max. -85kPa) in low compressed air (~3bar) Modular system Quick response time & High flow Integrated with air control valve & vacuum release valve Push-in type direct hose fitting Easy to assemble & disassemble control valve unit Order No. CU 0 - M4 - A - PG 3 4 Model CU 0 - Body type Control Unit for Micro cartridge VC0 3 Valves Air Supply Vacuum Release A (N.C. : Normal Closed) (N.C. : Normal Closed) B (N.C. : Normal Closed) - Only CL type valve is available S - Single unit M - Stack M4-4Stack M6-6Stack M8-8Stack M0-0Stack 4 Vacuum Switch No mark - Starndard (P)C - M8-3Pin Connector type (P)G - LED wire type(3m lead wire) Remark : (P) Output type : PNP open collector VCM8 4 : ㆍM8-3pin female connector ㆍAvailable for C or PC type 5 Sealing No mark - Starndard (NBR) V - Viton E - EPDM Specifications subject to change without notice.

Vacuum Flow (Nl/m) Vacuum Flow (Nl/m) VACUUM PUMP Pump Performance Data Model Max. Vacuum -kpa (-mmhg) Supply Air pressure (MPa) 0 (0) Vacuum flow (Nl/min) at different vacuum level kpa (-mmhg) 0 (75) 0 (50) 30 (5) 40 (300) 50 (375) 60 (450) 70 (55) 80 (600) 90 (675) 50 0..5 6.3..6 0.7 - - - - - VC0.. 85 0. 4. 9.4 3.3..4 0.8 0.4 0.8-83 0.6 6.5.9 5..3.4.3 0.9 0.3 0. - Model Supply Air pressure (MPa) Consumption (Nl/min) 0 (75) Time, s/l, to evacuate a volume to different vacuum level kpa (-mmhg) 0 (50) 30 (5) 40 (300) 50 (375) 60 (450) 70 (55) 80 (600) 90 (675) 0. 6.8 0.68 3 6..8 7. - - - - VC0.. 0. 9.6 0.4.48 4.3 6.9 9. 5.3 7.4 50. - 0.6 0.6 0.34.6 3.9 7 0.4 7.5 30.9 6.4 - Vacuum flow (Nl/min) at different vacuum level 0.Mpa 0.Mpa 0.6Mpa Evacuation time 0.Mpa 0.Mpa 0.6Mpa 8 70 6 4 0 60 50 40 8 6 4 0 0 0 0 30 40 50 60 70 80 90 30 0 0 0 0 0 0 30 40 50 60 70 80 90 Vacuum level (-kpa) Vacuum level (-kpa) Application 3 Specifications subject to change without notice.

Dimension Standard MC 0 - S M5 Valve & Switch type MC 0 - S - C - PG Specifications subject to change without notice. 4

Dimension Valve & Switch type MC 0 - S - A - PG Vacuum Release Valve Air Supply Manifold type MC 0 - M6 - A - PG Vacuum Release Valve Air Supply 5 Specifications subject to change without notice.

Dimension Control unit for MC0 CU 0 - M4 - A - PG Vacuum Release Valve Air Supply Specifications subject to change without notice. 6