Tebis application software

Similar documents
Tebis application software

Tebis application software

Application description

0701 CO Light, HVAC, Monitoring, Brightness

Installer Manual KNX Touchscreen Thermostat

User Manual Doc.Ref : JA-KNX-UM. JA-KNX Jablotron KNX Interface ELAUSYS JA-KNX. KNX Interface for Jablotron alarm system.

KNX/EIB - Product database - Application description

KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no )

Use of the application program. Functional description. instabus EIB Application program description. October CO Touch-Manager wave

RF-KNX / TP-KNX MEDIA COUPLER CO KNX 002

Info-Display xx

User Manual Doc.Ref : EVO-KNX-UM. EVO-KNX Paradox KNX Interface ELAUSYS EVO-KNX. KNX Interface for Paradox alarm system. User Manual.

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

KNX WS1000 Style. Building Control System. Installation and Operation

ST3124. KNX Blind Actuator DC 4-fold. Operation and Installation Manual

Product and Applications Description

Devices for Special Applications

Electronic controllers. Comfort embellishes everyday life

Connections, displays and operating elements C D E G H. Installing the control unit

Owners manual animeo Solo

PRESENCE DETECTOR. PD-C360i/8 mini KNX PD-C360i/12 mini KNX / 13 7 REMOTE CONTROL PRESENCE DETECTOR

Rev KNX Technical Reference Manual Busch Präsenz tech 6131/ /11-500

OPERATING INSTRUCTIONS

Synco-GAMMA Application Guide. School building class room. Answers for infrastructure.

RAy SNMP. Application notes.

Operating instructions

Technical Manual MDT Motion Detector

NEWS THEBEN THEBEN 2

Intelligent Visualization Software

Home intelligence PRODUCT CATALOG FIBARO SYSTEM

Interior blinds and curtains guide M O T O R S A N D A U T O M A T E D S Y S T E M S R A D I O T E C H N O L O G Y S O M F Y

VIII - Advanced capabilities of KNX systems

UP 258E11 OPTISENS OFFICE

Zone Terminal, 2-fold, FM MT/U , GH Q R0111

application guide aged care

BiSens SWR-230V. Installation instructions (translation) Safety instructions. Safety instructions for radio operation

B.E.G. LUXOMAT KNX-OCCUPANCY DETECTOR

D-TECT 3 IP. GJD260 IP Motion Detector

Product and Applications Description

2CDC D Product manual ABB i-bus KNX LGS/A 1.2 Air Quality Sensor with RTC

Controller - 4 x 1-10 V outputs - BUS/KNX

Building and home evolution

D-TECT 2 IP. GJD230 IP Motion Detector

Alarm description DECS Contents

B.E.G. LUXOMAT net. KNX intelligent building automation using sensors from B.E.G.

Inside front page will be left blank

MyNice Welcome to your Nice World. The intelligent solution for the integrated management of the alarm system and of the home s automations.

Instruction Manual Model Backup Switch, 1 for 8

KNX Multitouch Pro. Menu of the KNX Multitouch Pro User manual. This document describes how to operate the user interface of the KNX Multitouch Pro.

SENSA MRE DDM MR

ProStar 325 UV-Vis Detector

BRINGING GLASS to life. Beauty from within... INNOVATION COMES BUILT-IN

Operation Manual. smart-house Controller BH8-CTRLZx

Auro KNX Manual. Auro KNX. Manual. basalte bvba hundelgemsesteenweg 1a 9820 merelbeke belgium. 1 / 23 v basalte

IP65 High Bay Dual Sense Sensor

technologies for life smart buildings DESIGN AND PRODUCTION MADE IN BARCELONA

Noval 90. The external venetian blind with linked slats. Noval 90. Linked slats external venetian blind. Baumann Hüppe Creators of light and shade

Direct Dim Microwave Presence/Absence Detector

16 and 16 plus User s Guide

Du line. Mastergenerator G3800 X016. Operation Manual. Fieldbus Installationbus

Animals:Goats:Bleat.Calls,Warbling.Baa,Movements.Rubbing,Barn,Medium.Close,Interior,BG.Dog.Barks 01:21.618

Burglar Alarm System 12: 30. Fri 03rd March. Partial Armed Disarmed. Technical Manual 03_

NeXT is a powerful stand-alone application running fully embedded in network cameras to perform an intelligent video surveillance for ATM devices.

DALI SPECIFICATION GUIDE

HyBo - Hydraulic Interface Unit AMBIENT HEATING AND DOMESTIC HOT WATER PRODUCTION FOR CENTRAL HEATING SYSTEM UNIT CODE EHIU1

integrated blinds

The WAVE Plus Instant Notification System for Schools and Colleges

IP65 High Bay Dual Sense Sensor

TOUCH PANEL INSTRUCTION MANUAL

M2M Services Ltd. RControl Alarm - Installer Manual V 1.0

Sensero-868/915 AC, Sensero-868/915 AC Plus Nr , , ,

Enjoy a new lifestyle feeling!

Synco living. Train the Trainer. Commissioning Safety & Security. Spring 2008 Page 1/21 Train the Trainer - Spring 2008

NOVEMBER 2017 Webinar New KNX Devices Nov JRA/S , LGS/A 1.2, TR/A 1.1. Webinar Competence Center Europe Building Automation

the connected Moving to home

Tri-level Control Sensor

Pandora would like to thank you for choosing our DXL 1100L service and security system

DALI MSensor 02 Multi-sensor for DALI system

Detailed operating instructions

Z-1500II and Z-3000II USER MANUAL Z-1500II und Z-3000II BEDIENUNGSANLEITUNG Mode D Emploi des Z-1500II et Z-3000II Machines à Fumée

PRODUCT CATALOG FIBARO SYSTEM

Desigo Total Room Automation User Guide Version 2.1. A6V _en_a_ Building Technologies

Total Connect Box. User manual

Intelligent living next generation SMART BUILDING TECHNOLOGY

Welcome to MultiSight TM Vision Sensor Hands-On Lab

Alarm description DECS Contents

Instructions manual. By-alarm. By-alarm Manager software

Refrigerated air dryers

DOCUMENTATION IPS640

Bespoke blinds, shutters & awnings

DOCUMENTATION IPS640

SA 2650 Kit User Manual

Web Services are based on Apache and Tomcat servers. The html/jsp (tags, beans) are fully customisable and extendable.

Single Story Enclosed Shopping Mall Smoke Control with FSCS Override - Metasys System Extended Architecture

HOA Annunciator Load Programming and Monitoring Instructions

INDOOR CLIMATE OF A SINGLE ZONE

Movement controller comfort, Flush-mounted (Up) xx, xx

External venetian blinds sunlight included 40% ENERGY SAVINGS WITH INTELLIGENT SUN SHADING

Application Sheet Fan coil unit with staged fan, heating and cooling coil (4 pipe) on triac output including lighting and blinds operation

Transcription:

Tebis application software Input/output shutters/blinds product RF descriptions Product reference Description TR521 2-fold inputs/1-fold output shutters/blinds embedded RF Input TR521 Output modules KN/EIB Connected loads Shutter and blind controls Priority Scene Status indication Visualisation system Shutters/blinds output Input module KN/EIB TR521 Connected load Up / Down Slat angle / Stop Wind alarm Rain alarm Priority Scene Visualisation system Status indication TR521 1 6T 7895a

Contents 1. Description of the functions...3 1.1 Input...3 1.2 Shutters/blinds output...4 2. Configuration and parameter setting...5 2.1 Inputs...5 2.1.1 Listofobjects...5 2.1.2 Setting the parameters...6 2.2 Shutters/blinds output...7 2.2.1 Listofobjects...7 2.2.2 Setting the parameters...7 3. Main characteristics...10 4. Physical address...10 5. Return to factory settings...10 TR521 2 6T 7895a

1. Description of the functions The application software of the STR521 can be used to configure the product s 2 inputs and its output. The main functions are as follows: 1.1 Input Emission of controls: The push buttons can emit controls for shutters and blinds, and scenes. Emission of controls: Shutters/blinds control Up, Down, Stop, Angle of the Blind Slats, Priority, Wind Alarm, Rain Alarm 1 or 2-button control Scene The Scene function emits a group of controls to various types of output to create the desired room conditions or scenarios. Example of scene 1: Leaving the dwelling (central lighting control OFF, shutters on the south side lowered to 3/4, other shutters open, heating shifted to Eco mode). Priority The Priority function allows an input to be forced into a state defined as UP or DOWN. Alarms The alarm 1 and alarm 2 functions can emit alarms cyclically from the automatic controls (anemometer, rain detector, light sensitive switch, etc.). Alarm 1 has a higher priority than alarm 2. TR521 3 6T 7895a

1.2 Shutters/blinds output Up / Down The Up/Down function allows a shutter, a blind with tilting slats, an awning or a Venetian blind, etc. to be moved up or down This function can also be used to open and close electric curtains. The control may come from push buttons (long press), switches or automatic controls. Slat angle / Stop The slat angle/stop function allows the user to alter the angle of the blind slats or to stop its movement in progress. This function allows the user to modify the level of screening or to redirect light rays coming from outside. Control comes from push buttons: A short press on the up/down push button. Wind Alarm and Rain Alarm The alarm functions allow the blinds or shutters to be set in a predefined, configurable state. These functions have the highest priority. No other control is considered if an Alarm is active. Only an end-of-alarm can reauthorise the other controls. Priority The Priority function allows the user to force a shutter or blind into a defined position. This control has priority, but a lower priority than the alarms. No other control is considered if a Priority is active. Only Endof-Priority controls or alarms will be considered. Scene The Scene function allows a set of outputs to be regrouped. These outputs can be set to a predefined, configurable status. A scene is activated by pressing on a single push button. Each output can be included in 8 different scenes. Status indication The Status Indication 1-bit function allows the previous movement of the shutter or blind to be sent. TR521 4 6T 7895a

2. Configuration and parameter setting 2.1 Inputs 2.1.1 List of objects Functions ON/OFF 1-button shutters/blinds 2-button shutters/blinds Scene Status indication Slat angle / Stop Up / Down Scene Priority Alarms 1 Alarms 2 TR521 5 6T 7895a

2.1.2 Setting the parameters Parameter setting: Input channel function The product can emit controls for lighting, shutters and blinds, heating settings and scenes. Parameter setting screen Parameters Description Value Channel function This parameter allows the type of function associated with each input to be selected. Shutters / blinds, Up / Down - Shutters / blinds, Up - Shutters / blinds, Down - Shutters / blinds, Up Priority - Shutters / blinds, Down Priority - Shutters / blinds, Alarm 1 - Shutters / blinds, Alarm 2 Scenes 1-8 Default value: Shutters / blinds, Up Channel function: Shutters / blinds, Up / Down - Shutters / blinds, Up - Shutters / blinds, Down Shutters / blinds, Up / Down This function allows the shutters or blinds to be controlled with a single button (Input). The function switches after each push (Down, STOP, Up, STOP). Altering the angle of the slats is not possible. Shutters / blinds, Up This function allows the shutters or blinds to be controlled from two push buttons (Inputs). Emission of the Up control, on closure of the input contact or on pressing the push button, and emission of the Slat angle / Stop object (short press). Shutters / blinds, Down. This function allows the shutters or blinds to be controlled from two push buttons (Inputs). Emission of the Down control, on closure of the input contact or on pressing the push button, and emission of the Slat angle / Stop object (short press). Channel function: Shutters / blinds, Alarm 1 - Shutters / blinds, Alarm 2 These functions enable cyclic emitting of alarms from the automatic controls (anemometer, rain detector, light sensitive switch, etc.). To set the shutters to the security position in the event of bad weather: linking the Alarm 1 and Alarm 2 functions to the Alarm 1 and Alarm 2 objects of the Shutters / blinds output modules. These functions have the highest priority. (Alarm 1 has a higher priority than alarm 2) Channel function: Scenes 1-8 The Scene function emits a group of controls to various types of output to create the desired room conditions or scenarios. (Panic switch, television, etc.). The value of the Scene object is defined at the time of selection of the function. TR521 6 6T 7895a

2.2 Shutters/blinds output 2.2.1 List of objects 2.2.2 Setting the parameters Up / Down and Status indication The Up/Down function allows a shutter, a blind with tilting slats, an awning or a Venetian blind, etc. to be moved Up or Down. This function can also be used to open and close electric curtains. The control may come from push buttons (long press), switches or automatic controls. Description of the Status indication 1-bit object: 0 : last upward movement 1 : last download movement Up / Down Up / Down function Output Parameters: - Complete Up movement duration: - Duration 1-bit Status indication Parameters Parameters Description Values Complete Up movement duration This parameter defines the duration of contact closure for a complete Up movement. 0 to 500 s in steps of 1 s Default value: 120 s. TR521 7 6T 7895a

Slat angle / Stop function The slat angle/stop function allows the user to alter the angle of the blind slats or to stop its movement in progress. This function allows the user to modify the level of screening or to redirect light rays coming from outside. This function is engaged by the Slat angle / Stop object. The desired angle is obtained by a succession of control pulses. Slat angle / Stop Slat angle/stop function Output 1-bit Status indication Alarm 1 and Alarm 2 functions The alarm functions allow the blinds or shutters to be set in a predefined, configurable state. The wind alarm is engaged by the Alarm 1 object and the rain alarm by the Alarm 2 object. These functions have the highest priority. Alarm 1 has a higher priority than alarm 2. No other control is considered if an alarm is active. Only an end-of-alarm can re-authorise the other controls. Alarm 1 Alarm function Output Alarm 2 Parameters: - Position on alarm: - Maintain - Upper position - Lower position 1-bit Status indication TR521 8 6T 7895a

Parameters Parameters Description Values Position on alarm This parameter defines the position of the blind or shutter when the Wind Alarm function is activated. Maintain, Upper position, Lower position. Default value: Maintain. Priority function The Priority function allows the user to force a shutter or blind into a defined position. This function is started by the Priority object. This control has priority, but a lower priority than the alarms. No other control is considered if a Priority is active. Only Endof-Priority controls or alarms will be considered. Priority Priority function Output Parameters: - Status after priority: - Maintain - Inversion 1-bit Status indication Description of the Priority object. Value Behaviour of the output 00 End-of-Priority 01 End-of-Priority 10 Priority ON (Up) 11 Priority OFF (Down) TR521 9 6T 7895a

Parameters Description Values Status after priority This parameter defines the status of the output after a Priority. Maintain, Inversion - Maintain: maintains the output in the status which existed before the Priority. - Inversion: inversion of the output status with respect to that which existed before the Priority (Down goes to Up and Up goes to Down). Default value: Maintain. 3. Main characteristics Product TR521 Maximum number of group addresses 32 Maximum number of associations 50 Parameters 8 s 11 4. Physical address Physical addressing of the radio products is done from the plug-in of the TR131. In the Physical addressing menu, select Physical addressing, then follow the instructions which appear on the screen. Default input / output links exist in the products but are none the less invisible in ETS. To configure the product, proceed as if these links did not exist. 5. Return to factory settings The return to the factory settings of the radio products is done from the plug-in of the TR131. If the product forms part of the installation (recognised by the TR131): In the Physical addressing menu, select Return to factory settings, then follow the instructions which appear on the screen. If the product does not form part of the installation (unrecognised by the TR131): In the menu Physical addressing, select Product outside installation, select Bi-directional product, then follow the instructions which appear on the screen. TR521 10 6T 7895a