Unifying Alarms and Operating Envelopes for the Achievement of KPI s and Business Objectives

Similar documents
Q&A Session from Alarm Management Workflow Webinar (Apr.24/2013)

2012 Honeywell Pacific Users Group. Sus tain.ability.

Enhance Alarm Management

Diagnostics with fieldbus

DynAMo Alarm & Operations Management

Real Time Pipeline Leak Detection on Shell s North Western Ethylene Pipeline

SIL DETERMINATION AND PROBLEMS WITH THE APPLICATION OF LOPA

Alarms and Events. Defining Alarm Conditions. Database-Generated Alarms

BRIDGING THE SAFE AUTOMATION GAP PART 1

DeltaV Analyze. Introduction. Benefits. Continuous automated DeltaV System alarm system performance monitoring

Critical Condition Management on a Corporate Scale. Lyondell Is a Major Global Chemical Company

Cold Storage Management Standard Operation Procedure

A SURVEY OF OCCUPANT RESPONSE TOWARDS AN AUDIBLE FIRE ALARM

Statistical cluster analysis and visualisation for alarm management configuration. Butters, T D and Güttel, S and Shapiro, J L and Sharpe, T J

Safety Instrumented Systems

Next Generation Alarm Management With DynAMo Alarm and Operations Management

Influence of the magnitude of the angle of attack on the voltage produced by a miniature wind turbine

Combining Old and New Systems in Existing Buildings and Other Retrofit Tales. By Paul Jewett CFAA Technician Number 11

A GUIDE TO THE REGULATORY REFORM ORDER (FIRE SAFETY) 2005 (RRO)

Implementing a Funeral Home Emergency Action Plan

Corporate. Management. Line. Management. Plant. Manager HSSE. Maintenance Manager. (Plant. Operations Manager. Process Safety) Plant.

/ / White Paper. Focusing on user experience

THE RELIABILITY OF RADON REDUCTION TECHNIQUES. CB Howarth

EFDC Draft Local Plan Consultation Theydon Bois Guidance Notes Extended Version

Alarm Management Standards Are You Taking Them Seriously?

Lone Worker USER TRAINING

Affordable wireless monitoring without compromise

2012 Honeywell Users Group EMEA Tyron Vardy A Guide to Effective Alarm Management

Product introduction Layers of Protection Layer 3: Safety System Instrumented & Mechanical. Layer 2: Alarms Manual action needed

Fire alarm provisions for alerting the Fire Service

ADIPEC 2013 Technical Conference Manuscript

Unwanted Fire Alarms. Marty Ahrens National Fire Protection Association 1 Batterymarch Park Quincy, MA (617)

Museum Archive Dehumidification in Hot & Humid Climates

2015 Honeywell Users Group Europe, Middle East and Africa. Incident Response at your Fingertips Adrian Fielding, Honeywell

Presented at the ISPE ISA Automation Forum VP, Engineering Services

Economic and Effective Alarm Management

Net2. Total Access Control.

Net2 Access Control. Paxton Access

excellence in Dependable Automation ALARM MANAGEMENT

The diagram shows the inside of an incorrectly wired three-pin plug. What two changes need to be made so that the plug is wired correctly?

Lesson Plan. homework check: NPM 9 p. 424 # 1 6, 8. note: Optimum Area and Perimeter

HYDROCARBONENGINEERING June June 2015

Grower Summary PO 005

Dell DR Series Appliance Cleaner Best Practices

Construction Set: Smart Home

ABB Ability System 800xA Alarm Management

Audio Verified Alarms Best Practices

Alarm Services. Introduction. Benefits. Service Data Sheet October Know and improve your alarm performance

Home Fires Are Common, Deadly and Preventable

Netbiter Tank Sensor

Wildlife Food Plot Project

Pushing Process Limits Without Compromising Safety

DEFECTOVISION IR. Non-Destructive Testing of Steel Billets and Tubes

What's new in LogTag Analyzer 2.8

DeltaV Analyze. DeltaV Analyze. Introduction. DeltaV Product Data Sheet. Continuous automated DeltaV System alarm system performance monitoring

Today, we re going to talk about emergency action and fire prevention. We hope we never have to face an emergency situation like a fire in our

Cool, calm and collected No cause for alarm on the Grane oil rig

Intelligent alarm management

Bimetal Disc Thermostat. Product Information and Application Notes

Alarm Management. Version Prepared by: Michael Davis- Hannibal. Softcon Software Control Services (Pty) Ltd.

Patriot Systems Limited

Patriot Systems Limited

Smart Combiners Installation Guide. For Obvius A89DC-08 sensor modules

The Top 10 Worst Performing Alarm Systems in Industry

5 Cool Tips for Getting the Right Air Conditioning System pg. 1

999 AMBULANCE POLICE

A guide to the changes between BS 8418:2010 and BS 8418:2015

Control System Studio - CSS - Alarm Handling

Ovation Alarm Management System

Video Verified Alarms Best Practices

Exception Handling for Optimal Batch Production

Energy Using Products Directive: Implementation of Lot 17

Integrated but separate

80-6-ISD A Better Solution for Proper Space Air Distribution

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12

Compact Product Suite Compact HMI 6.0 Overview ABB

Session Four Functional safety: the next edition of IEC Mirek Generowicz Engineering Manager, I&E Systems Pty Ltd

Alarm Management Services

Functional Safety: the Next Edition of IEC 61511

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

Think System Solution to get it right first time

by WebWay CONXTD Home Transforming Security Monitoring

6 th Pipeline Technology Conference 2011

THE SIGNIFICANCE OF RELIABLE PRESSURE CONTROL IN OILFIELD BURNER SYSTEMS

02 21st Century Trends Resources 8/24/2017. Trends in Human Machine Interface (HMI) Old School Trends. The Future of HMI

DYNAMO ALARM MANAGEMENT

Electrical Fires in Finland

Session Number: 3 Making the Most of Alarms as a Layer of Protection

NEMA Standards Publication SB Fire Service Annunciator and Interface

Process Simulation and Optimization of Cryogenic Operations Using Multi-Stream Brazed Aluminum Exchangers

ENFORCER OWNER'S MANUAL. SLI 840 / SLI 840C (315 MHz) SLI / SLI 840C-4 ( MHz) Remote Controlled Keyless Entry System with Alarm

3. PLAN AND IMPLEMENT A CROP MONITORING PROGRAM

Alarm Enforcement or not?

New requirements for IEC best practice compliance

Effective Alarm Management for Dynamic and Vessel Control Systems

INTEGRA. Alarm control panel. Uncompromised Security for Your Company

White Paper: CCPS Process Safety Metrics Review Considerations from an ASM Perspective

Guide to Successful Continuous Temperature Monitoring in Medical Refrigerators and Freezers

Stavros Chrysanthou Madrid DynAMo Alarm Management Secrets to unlocking complete Operational Integrity

Embracing Change: High Performance Graphics to Improve Operations Water/Wastewater Case Study

Transcription:

Geometric Process Control Unifying Alarms and Operating Envelopes for the Achievement of KPI s and Business Objectives Robin Brooks, Alan Mahoney, John Wilson, Na Zhao, Process Plant Computing Ltd (PPCL), Gerrards Cross, UK Timothy Triplett, Coherent Technologies Inc., Palestine, Texas Robin_Brooks@PPCL.com Copyright PPCL 2010 1

The Role of the Operator Control the Equipment ALARM!! Meet Business Objectives Respond to Alarms Copyright PPCL 2010 2

The Role of the Operator What, apart from the Operator, connects? Control the Equipment Alarms Business Objectives Copyright PPCL 2010 3

The Role of the Operator What, apart from the Operator, connects? Control the Equipment Alarms Business Objectives An Operating Envelope Copyright PPCL 2010 4

The Role of the Operator What, apart from the Operator, connects? Control the Equipment Alarms Business Objectives An Operating Envelope How to see it How to use it Copyright PPCL 2010 5

Alarm Terminology - 1 Economic Alarms Emergency alarms, HiHi-LoLo Alarms Must be attended to Now. Sometimes based on metallurgical properties eg. Max tube temperature Warning alarms, Hi-Lo Alarms An acceptable operator response can be to ignore alarms because many are false... sometimes this will be wrong Alerts inside HiLo Limits, informal, not under change control This is too many levels so there is a trend to combine HiHi-LoLo into Safety Alarms. 100% 0% ESD Limit High/High Emergency Alarm Limit High Warning Alarm Limit Operating Point Low Warning Alarm Limit Low /Low Emergency Alarm Limit ESD Limit Copyright PPCL 2010 6

Alarm Terminology - 2 Safety Alarms Safety & ESD Alarm Limits Often automatic with no operator intervention possible The GPC method should not be used for Safety Alarm limits. Better Economic Alarms reduce the demand rate on Safety Alarms hence the probability of failure on demand (PFOD) thus increasing plant safety - EEMUA 100% 0% ESD Limit High/High Emergency Alarm Limit High Warning Alarm Limit Operating Point Low Warning Alarm Limit Low /Low Emergency Alarm Limit ESD Limit Copyright PPCL 2010 7

Alarm TRIPS Bursting Discs Automatic Safety Systems Economic Alarms Normal Operation Understanding of Alarms Human Intervention Required No Intervention Allowed $ Expensive $ Emergency Shutdown System Relief Valves We think of Alarms defining the boundary of the Normal Operation Operating Envelope which is where we achieve Business Objectives Copyright PPCL 2010 8

TRIPS Bursting Discs Alarm Automatic Safety Systems Economic Alarms Normal Operation Human Intervention Required No Intervention Allowed $ Expensive $ Emergency Shutdown System Relief Valves Reality is different. Because we don t know where the boundary of Normal is we have to widen the Alarm Limits to keep annunciations to a tolerable level but as the Alarms were meant to define the boundary of Normal, we just changed the definition of Normal Copyright PPCL 2010 9

TRIPS Bursting Discs Human Intervention Required Automatic Safety Systems Normal Operation No Intervention Allowed $ Expensive $ Understanding of Alarms Emergency Shutdown System Relief Valves Rationalising Alarms using one-at-a-time methods reduces response time, worsens achievement of Operating Objectives and makes process control harder because we only widen limits to reduce the Annunciation Rate and rarely have time to narrow them. Copyright PPCL 2010 10

TRIPS Automatic Safety Systems Economic Alarms Normal Operation Emergency Shutdown System We need this picture of process and result data for many variables Alarm Bursting Discs Human Intervention Required No Intervention Allowed $ Expensive $ Relief Valves Copyright PPCL 2010 11

2-d simplified Operating Envelope Quality Constraints Q>a*PV1+b*PV2+c What happens when PV3, PV4 etc changes? Process variable Good Product Operating Envelope PV1 Nearly Redundant quality parameter Redundant quality parameters Process variable PV2 Copyright PPCL 2010 12

2-d simplified Operating Envelope Quality Constraints Q>a*PV1+b*PV2+c Process variable PV1 Good Product Operating Envelope What happened when PV3, PV4 etc changed Was a nearly redundant quality parameter but now very important Still a redundant quality parameter but much less so Process variable PV2 Copyright PPCL 2010 13

N-d Operating Envelope Because we can t visualise an n-d envelope we use Alarms as probes intended to touch its surface in many places. But we haven t had a way to set alarm limits to do this Copyright PPCL 2010 14

The Observed Problem - Plentiful data but no Information Copyright PPCL 2010 15

The Root Problem Human brains are visually oriented A picture is worth 1000 words We understand graphs not numbers But we can only draw a graph of 2 or 3 variables.. 435 x-y graphs are necessary to show all the interactions between just 30 variables. Copyright PPCL 2010 16

One point in a 27-dimensional graph Copyright PPCL 2010 17

13,444 points in a 27-dimensional graph 178 variables at 5-minute intervals for 3 months Notice how clearly different Modes of operation, process excursions and where the plant has actually operated stand out. This cloud of points is the population of the All Previous Experience Operating Envelope Copyright PPCL 2010 18

TRIPS Existing HiLo Alarm Limits The existing alarm limits were imported from the DCS. Operation with no standing alarms was never achieved in this 92-day period. Which Operating Envelope are these alarm limits wishing to identify? Copyright PPCL 2010 19

TRIPS Performance of Existing Alarms Annunciations per hour and Standing Alarm Count over 92 days. Mode shown by colour Copyright PPCL 2010 20

Three Operating Modes TRIPS Pink shows the Kerosene Mode Operating Envelope Blue shows the LGO Mode Operating Envelope Black shows Stand-by Mode Operating Envelope Only one set of Alarm Limits for all three Modes lumped together. A permanent compromise Operating Envelope that is never right Copyright PPCL 2010 21

New Lumped-Mode Alarm Limits Standby Mode in green. Some alarm limits have been moved inwards to ensure known extremes of operation are alarmed. Copyright PPCL 2010 22

Performance of Lumped-Mode Alarm Limits These limits might meet EEMUA Guidelines for Alarm Performance but wont help the Operator achieve the plants operating objectives. A Separate set of Alarm Limits are needed for each Mode Copyright PPCL 2010 23

Starting Point for the Alarm Review Three months of operating data for Kerosene Mode with existing alarms moved in to the boundaries of where the plant has actually operated. In the Review Meeting individual alarm limits will be moved to exclude known bad operation and deleted if considered unnecessary. The next slide gives an example of how the screen might then look together with trend plots for the whole year of Annunciation Rate per hour and Standing Alarm Count. These update automatically as further changes are made to the alarms. Copyright PPCL 2010 24

In the Alarm Review Meeting - 1 Several alarm limits have been moved inwards to eliminate operation that the Review Meeting considers undesirable. The eliminated points are in black and are less than 2% of all the data for the year. These are the points that would be alarmed by one or more variables if experienced again in the future. The next slide shows the Annunciation Rate and Alarm Count that would result. Copyright PPCL 2010 25

In the Alarm Review Meeting - 2 Annunciations/hour and Standing Alarm Count for 92 days of operation in Kerosene Mode. Further changes to the Alarm Limits will update these trends. The Review Meeting might use these pictures to lead them to a closer investigation of the period of alarm activity to the right of the centre line. Perhaps the operating log will show that it corresponds to a known plant incident. Copyright PPCL 2010 26

Using Alarms to achieve KPI s Turquoise the Operating Envelope for in-specification Kerosene Pink the No-Alarms Operating Envelope for the new alarm limits Should Pink be larger than Turquoise? Why don t we operate inside the in-spec Envelope now? Copyright PPCL 2010 27

Using Alarms to achieve KPI s Turquoise the Operating Envelope for in-specification Kerosene Pink the No-Alarms Operating Envelope for the new alarm limits Should Pink be larger than Turquoise? Why don t we operate inside the in-spec Envelope now? Is it because we couldn t see it until now? Copyright PPCL 2010 28

Using Alarms to achieve KPI s Alarm performance of the in-spec Envelope is poor so move to it in several stages of improving control followed by tightening of limits Copyright PPCL 2010 29

Better Alarms Improve Process Operation before after New HiHi/LoLo limits forced better operation to avoid nuisance Trips. Trip Rate at implementation 2%, 2 years later 0.1% Copyright PPCL 2010 30

OK, so what s better?? The ability to visualise whole systems The interaction of alarms Effect of alarm combinations Estimate alarm-on periods Maximise operator response time Earlier warning Eliminate nuisance alarms SPEED a complete analysis in a few minutes Copyright PPCL 2010 31

Process Performance Monitoring CVE Graphical presentation of KPI s with control limits and prebuilt Queries for different timeperiods allows easy understanding Still a pdf report but graphical and many fewer pages Report production automated Today s many-page pdf report Ves file can be provided to allow further investigation or drill-down Copyright PPCL 2010 32

Alerts Recognise that defining the Operating Envelope with fixed alarm limit values implies Independence between process variables hence process operation in a rectangular box (a hypercube) enclosing the envelope Alerts account for interaction between variables so give a much better model of an Operating Envelope. Copyright PPCL 2010 33

The Used Operating Region Used Operating Region Range P1 2-D Range P2 The Operating Zone Copyright PPCL 2010 34

The Best Operating Zone Concept Used Operating Region Range P1 2-D Range P2 The Operating Zone What would a 20-variable Zone look like? Copyright PPCL 2010 35

Using Alarms to achieve KPI s Turquoise the operating envelope for in-specification Kerosene Pink the no-alarms operating envelope for the new alarm limits Does Pink need to be larger than Turquoise? Why don t we operate inside the in-spec envelope now? Perhaps it is because we haven t been able to see it? Copyright PPCL 2010 36

Building the Alerts Model 1. Using Visual Explorer, decide with hindsight where you should have operated by applying objectives (eg. Inside HiLo Alarm Limits) as a query. 2. Focus on the yellow points, remove unwanted variables and save as. These points represent best past experience to be enforced in the future. 3. Open the file in Process Modeller to create the envelope ready for use. Operating objective is to remain an interior point of the envelope. Copyright PPCL 2010 37

Alert Limits Keep the process inside the Green envelope to keep the process inside its HiLO alarm limits. This is the job of Process Control Copyright PPCL 2010 38

Correcting Alert Violations Copyright PPCL 2010 39

Alarms and Alerts in context Copyright PPCL 2010 40

Public and Private Alerts HiLo Alarms ignore interaction between variables so give late warning of process excursions GPC Alerts take interaction fully into account and display to the operator as a picture. Their role is to keep the process inside the HiLo Limits. They provide corrective advice for the operator Todays Operator Alerts are values set by the operator and used at his discretion. They can co-exist with the new GPC Alerts. We suggest Public and Private Alerts as a naming convention. Copyright PPCL 2010 41

Results of Field Trial Quality Improvement 2% immediate Process KPI Improvement More expected as Operators gain more confidence and implement more of the Advice More expected when the Optimiser is turned on Operations Improvement High acceptability of operator Advice Advice reduced start-up time by factor of 6 Copyright PPCL 2010 42

Results - 2 HiLo Alarms Went from 51% correct to 90% correct on first attempt Now even better so less dependent solely on operator vigilance Alerts Previously impossible to set at constant values Now multi-variable alarms are so good they are advising operators where to operate and have warned of danger of equipment damage long before any one variable detected a problem. Copyright PPCL 2010 43

The New GPC Alarm Rationalisation TRIPS Make Consistent Tighten Objectives Copyright PPCL 2010 44

Geometric Process Control for Rationalising Alarm Limits Benefit from Fewer false alarms increased belief in remainder Lower annunciation rates More time for the operator to think and respond Earlier warnings of process excursion A Safer Process with higher KPI achievement And Saves at least 20% of man-hours in Alarm Review Meetings Reduces Process Engineers time for Change Management Move towards the in-spec Operating Envelope Copyright PPCL 2010 45