Electric Griddle. Owner s Manual

Similar documents
ELECTRIC GRIDDLES TMGE24, TMGE36, TMGE48. Installation and Operation Instructions 2M-Z12971 Rev. - Oct. 1, 2009 MODEL TMGE36 IL1880

ELECTRIC GRIDDLES MODELS CHROME MODELS 724TA, 736TA, 748TA, 760TA, 772TA 724TCHSA, 736TCHSA, 748TCHSA, 760TCHSA, 772TCHSA

BROIL-O-DOG MODEL 174CBA, 174SBA 175CBA, 175SBA. Installation and Operation Instructions 175CBA. 2M-Z3755 Rev. L 10/01/2015.

ELECTRIC GRIDDLES MODELS CHROME MODELS 724TA, 736TA, 748TA, 760TA, 772TA 724TCHSA, 736TCHSA, 748TCHSA, 760TCHSA, 772TCHSA

SOUP KETTLE COOKERS and HOLDERS MODELS 7C, 7H, 11C, 11H

STAR-MAX GAS GRIDDLES MODELS 615MA 624MA 636MA 648MA 615TA 624TA 636TA 648TA 624TSPA 636TSPA 648TSPA

LIGHTED WARMERS MODEL 11 QUART. Installation and Operation Instructions 11WLA. 2M-Y5817 Rev. I 12/14/10

STAR-MAX PROPANE GAS GRIDDLE

HOT FOOD HUMIDITY CABINET

DRAWER ROLL/ BUN WARMER

HOT FOOD HUMIDITY CABINET

VERTICAL CONTACT TOASTER

COMBINATION HOT DOG STEAMER & BUN WARMER

Drop-In Induction Range

3 1/2 QUART WARMERS. MODEL 3W SERIES Installation and Operation Instructions 3WLA-P. 2M-Y8316 Rev. M 6/10/2013

CONVEYOR TOASTER MODEL QCS QCS Installation and Operation Instructions 2M-HG0657 Rev. D 6/13/05

BROIL-O-DOG MODEL 174CBA, 174SBA 175CBA, 175SBA. Installation and Operation Instructions 2M-Z3755 Rev. J 10/4/06 175CBA.

HOT FOOD HUMIDITY CABINET

CONVEYOR TOASTER MODEL QCS BH, RCS BH SERIES. Installation and Operation Instructions 2M-HG0659 Rev. D 4/ QCS BH

Electric Cruise Line Single Broiler w/ Cabinet Base CLB V CLB V

Product Identification

LIGHTED WARMERS MODEL 11 QUART. Installation and Operation Instructions 11WLA. 2M-Y5817 Rev. I 12/14/10

BROIL-O-DOG MODEL 174CBA, 174SBA 175CBA, 175SBA. Installation and Operation Instructions 175CBA. 2M-Z3755 Rev. L 10/01/2015.

REFRIGERATED CONDIMENT RAIL

JetStar COUNTER POPCORN POPPER. MODEL 39 & 86 Series Installation and Operation Instructions 2M-Y8397 Rev. O 7/12/10 86-S

ULTRA-MAX GAS RADIANT CHARBROILER. ULTRA-MAX GAS LAVA ROCK CHARBROILER MODELS 8024CBB, 8036CBB, 8048CBB, 8060CBB, and 8072CBB

Electric Cruise Line Double Broiler w/ Oven Base CLB36S-2-440V CL36B2OLF440

Instruction Manual for the Globe Electric Countertop Griddles Model PG24E & PG36E

OWNERS MANUAL For IN ROOM BREWING SYSTEM MODEL REFILLABLE CAPSULES K901. Includes: Installation Use & Care Servicing Instructions

SPLIT LID TABLE TOP TWO SIDED GRILL

Instruction Manual for the Globe Electric Countertop Griddles Model PG24E & PG36E

Electric Griddles OPERATING/INSTALLATION INSTRUCTIONS

Instruction Manual for the Globe Electric Countertop Griddles Model GEG16, GEG24, GEG36 & GEG48

Professional Warming Drawer and Warming Drawer Cabinet

Installation, Operation, Maintenance, & Troubleshooting Model: CLG-36-S Electric Cruise Line Griddle Serial:

CONVEYOR SANDWICH TOASTER

BROIL-O-DOG MODEL 174CBA, 174SBA 175CBA, 175SBA. Installation and Operation Instructions 2M-Z3755 Rev. J 10/26/11 175CBA.

Refridgerated Topping Rail Model: RTR-8 Intended for other than household use. Unit must be kept clear of combustibles at all times.

HOT FOOD HUMIDITY CABINET

Installation, Operation, Maintenance, & Troubleshooting Model: CLS36-440V Electric Cruise Line Salamander Serial:

IRCS2-SBD Conveyor Toasters

Mobile Hot Food Merchandiser Series. Series: MHB Operation Manual

STANDARD FRYERS COUNTERTOP MODELS F-14 F-49 F-55 F-67 F-85 F-1725 OPERATION MANUAL. Includes INSTALLATION USE & CARE

OPERATION MANUAL COUNTERTOP ELECTRIC CHAR BROILERS. for. Models: B-40 B-44 B-50. includes: INSTALLATION, USE and CARE

OPERATIONS MANUAL DALPH1002, DALPH1503 PELLET HEATERS PALPH1002, PALPH1503 PLATE HEATERS. Alliance Products, LLC Murfreesboro, TN

Instruction Manual for the Globe Electric Countertop Panini/Sandwich Grill Models GPG1410 and GSG1410 Canadian Models GPG1410-C and GSG1410-C

COH-267. COH-2670W Half Size Convection Oven

DEEP FAT FRYER MODEL 510FF SERIES. Installation and Operation Instructions 510FF. 2M-Z15998 Rev. - 5/30/12

INSTRUCTION MANUAL. Full Size Gas Convection Oven

90 INDUSTRIAL PARK ROAD P.O. BOX 880, SACO, MAINE / (207) FAX (207)

HD-26, HD-36, HD-48 Heated Displays

HEATED DISPLAY CABINET

DH07, DH07A /DH08, DH08A CONVECTED AIR DISH HEATERS

Condiment Warmer. Instruction Manual Models #2252EX & #2253EX. Cincinnati, OH USA. Model #2252EX. Model #2253EX

PATRIOT INSTRUCTION MANUAL FMCOH-2670W HALF SIZE CONVECTION OVEN

Installation, Operation, Maintenance, & Troubleshooting Model: EQS-AP Quarter Size Convection Oven

ELECTRIC COUNTER TOP CONVECTION OVEN

ROLLING TORTILLA WARMER

Part No Revised: June TS1 TOASTER SYSTEM Instruction Manual Models # 5700 AND # 5700SF

Cheese Display Case. Instruction Manual Model #5580BV2 and Model #5580BV3 Model #5582 and Model #5583. Cincinnati, OH USA.

OWNERS MANUAL ELECTRIC STOVES

Models: DB-2-HF, DB-3-HF, DB-4-HF, and DB-5-HF. For Service Information, Call

INSTALLATION, OPERATION & MAINTENANCE AVANTCO SERIES 177AG OWNER S MANUAL

Hot Dog Hutch. Models HDH-3, HDH-3DR, & HDH-4 owner s manual. Manufacturing Numbers:

Model 2016, 2025, 2025BN, 2025ST Staging Cabinets Instruction Manual

Owner s Manual WARMER DRAWER. (Without Water Tray) Models WD-20, WD21A, & WD-35A. WD-20 Shown MANUFACTURING NUMBERS: P/N Rev.

USER MANUAL Gas Step Up Hot Plate

DEEP FAT FRYER MODEL 530TF & 530TEF SERIES. Installation and Operation Instructions 530TF. 2M-Z16001 Rev. - 5/31/2012

Hot Plate-Style Decanter Warmer

ST-120/2 ST-120/3 ST-240/4 Steam Table

5300, 5300CH, 5300EX, 5300FN

Installation, Operation, Maintenance and Service Instructions. Fryer Model: 130F

OPERATIONS MAINTENANCE MANUAL

Instruction Manual for the APOLLO Gas Countertop Griddle Models: Manually Controlled: AMG-24, AMG-36, AMG-48 & AMG-60

CRISP N HOLD FRIED FOOD HOLDING CABINET MODELS: CNH14, CNH18, CNH28, CNH40 OWNERS / OPERATORS MANUAL

PATRIOT INSTRUCTION MANUAL FMFW-1500W/C FULL SIZE COOKER/WARMER

R-RCM & R-RSB SERIES

Service Manual Models CPH2 & CPH3

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

Part No Revised January 30, 2007 SAFETY PRECAUTIONS

PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCES. This equipment is design engineered for commercial use only

Fried Food Warmers Series. Series: FW Operation Manual

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

TECHNICAL MANUAL TM... Fryer, Deep-Fat, Electric w/solid State Controls 440 Volt, 60 HZ, 3 Phase NSN:

THERMOSTATIC DROP-IN ELECTRIC GRIDDLE 136TDI, 148TDI, 160TDI

RW1HD RW2HD RW3HD RWN1 RWN2 RWN3

Instruction Manual. 36 in. and 42 in. Popcorn Staging Cabinets

Instruction Manual. Cheddar Easy All-In-One Cheese Corn Shop

TM... TECHNICAL MANUAL. Fryer, Deep-Fat, Electric w/solid State Controls NSN:

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers

Large Combo Warmer Instruction Manual Model #2206

ELECTRIC COUNTER TOP CONVECTION OVEN CCOF-4 CCOH-3, CCOH-4

MANUFACTURING NUMBERS: CORN CAROUSEL. Model CC-19 Series P/N /99. Owner s Manual

INSTALLATION AND OPERATING MANUAL

Instruction Manual for the Chefmate Countertop Soup Warmer Model CPSKB1

MINIVEYOR MULTI-PURPOSE OVEN

!"" #$% "!&' ( ( ) *

Portable Induction Ranges

Dogeroo & Super Dogeroo

Transcription:

Electric Griddle Owner s Manual Models T, T, T, 0T, T, TC, TC, TC, 0TC, TC, S, S, S, 0S, S, SC, SC, SC, 0SC, SC This manual includes material related to installation, use, cleaning, and care. Exploded view[s], as well as any available parts list[s] and wiring diagram[s] pertaining to the unit[s] covered by this manual are also included. This manual must be read and understood by all persons using or installing this appliance. Contact your Lang dealer if you have any questions concerning installation, use, or maintenance of this equipment. DO NOT DISCARD THIS MANUAL. T M-Z Rev. C 0.0

LIMITED EQUIPMENT WARRANTY Star Manufacturing [as well as its subsidiaries] warranties new products to be free from defects in material and/or workmanship for a period of one [] year from the date of original installation, except as noted below. Defects that occur as a result of normal use, within the time period and limitations defined in this warranty, will at Star s discretion have the parts replaced or repaired by Star or a Star-authorized service agency. THIS WARRANTY IS SUBJECT TO ALL LISTED CONDITIONS. Repairs performed under this warranty are to be performed by a Starauthorized service agency. Star will not be responsible for charges incurred or service performed by non-authorized repair agencies. In all cases, the nearest Star-authorized service agency must be used. Star will be responsible for normal labor charges incurred in the repair or replacement of a warrantied product within 0 miles (0. km) of an authorized service agency. Time and expense charges for anything beyond that distance will be the responsibility of the owner. All labor will need to be performed during regular service hours. Any overtime premium will be charged to the owner. For all shipments outside the U.S.A. and Canada, please see the International Warranty for specific details. It is the responsibility of the owner to inspect and report any shipping damage claims, hidden or otherwise, promptly following delivery. No mileage or travel charges will be honored on any equipment that is deemed portable. In general, equipment with a cord and plug weighing less than 0 lb. (. kg) is considered portable and should be taken or shipped to the closest authorized service agency, transportation prepaid. PORTABLE EQUIPMENT EXAMPLES LL fryer JR popcorn machine MC and MCP hot food NCPW and NCPW nacho merchandisers merchandisers QCS, QCS, and RCS toasters nacho cheese warmers except PD-A pretzel merchandisers WLA-series models condiment dispensers except specialty food warmers except HPD- and SPD-series models 0R, RW, and WSA models all pop-up toasters all butter dispensers all pastry display cabinets all nacho chip merchandisers all heat lamps all accessories CONTACT Should you require any assistance regarding the operation or maintenance of any Star equipment; write, phone, fax or email our service department. In all correspondence mention the model number and the serial number of your unit, as well as the voltage or type of gas you are using. Business hours are :00 a.m. to :0 p.m. Central Standard Time Telephone Star/Toasmaster..0 Lang.. Fax.. Email customerservice@star-mfg.com www.star-mfg.com www.langworld.com www.toastmastercorp.com WARRANTY EXCLUSIONS THE FOLLOWING WILL NOT BE COVERED UNDER WARRANTY. Any product which has not been used, maintained, or installed in accordance with the directions published in the appropriate installation sheet and/or owner s manual, including incorrect gas or electrical connection. Star is not liable for any unit which has been mishandled, abused, misapplied, subjected to harsh chemicals, modified by unauthorized personnel, damaged by flood, fire, or other acts of nature [or God], or which have an altered or missing serial number. Installation, labor, and job checkouts, calibration of heat controls, air and gas burner/bypass/pilot adjustments, gas or electrical system checks, voltage and phase conversions, cleaning of equipment, or seasoning of griddle surface. Replacement of fuses or resetting of circuit breakers, safety controls, or reset buttons. Replacement of broken or damaged glass components, quartz heating elements, and light bulbs. Labor charges for all removable parts in gas charbroilers and hotplates, including but not limited to burners, grates, and radiants. Any labor charges incurred by delays, waiting time, or operating restrictions that hinder a service technician s ability to perform service. Replacement of items subject to normal wear or items that can easily be replaced during a daily cleaning routine, such as but not limited to knobs, bulbs, fuses, quartz heating elements, baskets, racks, and grease drawers. Any loss of business or profits. ADDITIONAL WARRANTIES PRODUCTS PARTS LABOR Lang Chef-Series convection ovens years years Lang Strato-Series convection ovens years years Lang convection oven doors lifetime years Lang LG and Star Ultra-Max griddles, charbroilers, and hotplates Star-Max fryers, griddles, charbroilers, and hotplates years years years years Jetstar popcorn poppers years years Staltek roller grill coatings chrome griddle surfaces [against peeling] lava rock charbroiler grates, burners, and burner shields original Star, Lang, or Toastmaster parts sold to repair Star, Lang, or Toastmaster equipment years years 0 days 0 days The foregoing warranty is in lieu of any and all other warranties expressed or implied and constitutes the entire warranty. M-Z Rev A 0.0 i

TABLE OF CONTENTS Warranty i General Information Installation and Electrical Connection Wiring Diagrams Daily Operation Specifications Exploded View Parts List 0 M-Z Rev C Owner s Manual for Lang xx-series Electric Griddles

iii NOTES

SAFETY SYMBOLS These symbols are intended to alert the user to the presence of important operating and maintenance instructions in the manual accompanying the appliance. THOROUGHLY INSPECT YOUR UNIT ON ARRIVAL This unit has been tested for proper operation before leaving our plant to ensure delivery of your unit in perfect condition. However, there are instances in which the unit may be damaged in transit. In the event you discover any type of damage to your product upon receipt, you must immediately contact the transportation company who delivered the item to you and initiate your claim with that company. If this procedure is not followed, it may affect the warranty status of the unit. If damage or loss is not apparent until after equipment is unpacked, a request for inspection of concealed damage must be made with carrier within days. Please record the model number, serial number, voltage, and purchase date in the area below at the time of receipt.. Model Number Serial Number Voltage Purchase Date MAINTENANCE AND REPAIRS Contact your local authorized service agent for service or required maintenance. Please have the information in the above fields ready when you call to ensure a faster service. Using any part other than genuine Star factory supplied parts relieves the manufacturer of all liability. Due to periodic changes in designs, methods, procedures, policies, and regulations, the specifications contained in this document are subject to change without notice. Star reserves the right to change product specifications and design without notice. In regards to previously purchased equipment, such revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements. While Star International Holdings Inc. exercises good faith efforts to provide information that is accurate, we are not responsible for errors or omissions in information provided or conclusions reached as a result of using the specifications. By using the information provided, the user assumes all risks in connection with such use. When performing maintenance, power to the unit should be unplugged or turned off. PLEASE REFER TO THE WARRANTY PAGE FOR SPECIFIC WARRANTY INFORMATION. AUTHORIZED SERVICE AGENT LISTING Reference the listing provided with the unit or for an updated listing go to the website or call customer service to find an agent. Business hours: :00 a.m. to :0 p.m. Central Standard Time Telephone: --0 Fax: -- Email: customerservice@star-mfg.com Website: www.langworld.com Please visit www.starwebconnect.com/manuals.aspx for digital versions of any documents associated with this unit. M-Z Rev C Owner s Manual for Lang xx-series Electric Griddles

GENERAL SAFETY INFORMATION This equipment is designed and sold for commercial use only, and is intended for use by personnel trained and experienced in its operation. This is not sold for consumer use in and around the home nor for use directly by the general public in food service locations. Before using your new equipment, read and understand all the instructions and labels associated with the unit prior to putting it into operation. Make sure all people associated with its use understand the units operation and safety before they use the unit. GENERAL INSTALLATION INFORMATION The unit is shipped fully assembled with the exception of the legs which will need to be installed during the unpacking process. It is shipped ready to hardwire to an electrical connection adequate for its voltage and amp draw. If improper electrical supply can be determined through troubleshooting, contact a qualified electrician prior to using the unit. Should you require assistance, contact your local authorized service agent for any service or required maintenance. Set the unit so that the rear is 0. inches ( mm) higher than the front using the adjustable feet. Make certain the griddle has at least the minimum clearance on the sides and back as called out on the nameplate of the unit. Before using the unit for the first time, make sure to clean the unit properly. Refer to the Daily Operation section for cleaning instructions. VENTILATION Make certain not to obstruct the flow of combustion and ventilation air. Provisions for adequate air supply must be furnished. The legs supplied with the unit must be installed. Make certain that air intake openings in the bottom of the appliance are not obstructed, as they are essential for proper combustion and operation of the appliance. It is essential that some form of exhaust hood be provided over the griddle to carry off fumes and gases. The unit should never be directly connected to a flue or stack. ELECTRICAL CONNECTION For your protection we recommend that a qualified electrician work on connecting this griddle. He should be familiar with electrical installations and all electric codes. Proper connections and power supply are essential for efficient performance. The external wiring should be in conduit or an approved type of flexible cable suitable for operation at the temperature indicated on the wiring diagram for your unit, and of a proper size to carry the load. The supply circuit should be properly fused and equipped with a means of disconnecting, as required by local electrical code. The body of the griddle should be grounded. Before making any electrical connection to this unit, check that the power supply is adequate for the voltage, amperage, and requirements stated on the nameplate. This unit will be shipped ready to hard wire. Make certain to disconnect the unit from the power source before installing or removing any parts. Be absolutely sure that the ground connection for the receptacle is properly wired. Do not connect equipment to power without proper ground connections. Improper grounding may result in personal injury or fatality.

WIRING Models may be wired for operation in the field for either -phase or -phase power supplies by making line connections at the junction box located at the rear of the unit as described on the phase diagram.,, 0, and models are recommended to be wired for -phase operation. 0 and models are supplied with two junction boxes. CONNECT/PLUG UNIT INTO DEDICATED AC LINE WITH APPROPRIATE AMPERAGE/VOLTAGE AS SPECIFIED ON THE NAMEPLATE OF THE UNIT. DO NOT IMMERSE OR LET THE UNIT STAND IN WATER. DO NOT HOSE DOWN THE UNIT OR THE TABLE/COUNTER IF THE UNIT IS ON THE TABLE/COUNTER. KEEP AWAY FROM RUNNING WATER. M-Z Rev C Owner s Manual for Lang xx-series Electric Griddles

0 0 0 WIRING DIAGRAM 0 V and 0 V version S S 0 0 0 0 0 0 0 POSITION SWITCH POSITION SWITCH POSITION SWITCH S is the same with one additional section with the power connections being and. 0S griddles will use two connections with C being the same as one S and C being the same as one S. S griddles will use two connections with C and C each being the same as one S. SERVICE CONNECTIONS MODEL THREE PHASE SINGLE PHASE L L L L L,,,,,,,,,,,,,,,,,,,,, GRIDDLE ELEMENTS GRIDDLE PILOT LAMP CONTACTOR JUMPER TERMINAL BLOCK TEMP. CONTROL BOARD POSITION SWITCH TOGGLE SWITCH TRANSFORMER, CLASS 0 PROBE OVERTEMP STAT

0 0 WIRING DIAGRAM 0 V version S S 0 0 0 0V 0 V 0 YEL POSITION SWITCH BLU POSITION SWITCH POSITION SWITCH 0 S is the same with one additional section with the power connections being and. 0S griddles will use two connections with C being the same as one S and C being the same as one S. S griddles will use two connections with C and C each being the same as one S. SERVICE CONNECTIONS MODEL THREE PHASE SINGLE PHASE L L L L L,,,,,,,,,,,,,,,,,,,,, GRIDDLE ELEMENTS GRIDDLE PILOT LAMP CONTACTOR JUMPER TERMINAL BLOCK TEMP. CONTROL BOARD POSITION SWITCH TOGGLE SWITCH TRANSFORMER, CLASS 0 PROBE OVERTEMP STAT M-Z Rev C Owner s Manual for Lang xx-series Electric Griddles

WIRING DIAGRAM 0 V version T T T 0 0 V and 0 V version T T T 0 0 0 0T griddles will use two connections with C being the same as one T and C being the same as one T. T griddles will use two connections with C and C each being the same as one T. SERVICE CONNECTIONS MODEL THREE PHASE SINGLE PHASE L L L L L,,,,,,,,,,,,,,,,,,,,, GRIDDLE ELEMENTS GRIDDLE PILOT LAMP GRIDDLE THERMOSTAT TERMINAL BLOCK JUMPER [installed for 0 V, removed for 0 V]

DAILY OPERATION GRIDDLE CARE It takes very little time and effort to keep the griddle attractive and performing at top efficiency. If grease is permitted to accumulate, it forms a viscous residue and then carbonizes, making it extremely difficult to remove. To prevent this condition, the following suggestions for cleanliness should be followed. i. STANDARD STEEL SURFACE After each use, scrape the griddle with a scraper or flexible spatula to remove excess grease and food and maneuver it into the grease chute. If there is an accumulation of burned on grease and/or food, the griddle should be thoroughly scoured and reseasoned. Use pumice or griddle stone while the griddle is warm. Do not use steel wool because of the danger of steel slivers getting into the food. CHROME SURFACE After each use, scrape the griddle with a razor-sharp scraper. Following that, use a soft, damp cloth and a non-silicate, non-abrasive, non-chlorinated cleaner to wipe the surface clean. Follow this by wiping with a clean damp cloth with no cleaner. On chrome surfaces, never use pumice, griddle stones, abrasives, commercial liquid grill cleaner, and never strike the griddle surface with a sharp and/or hard instrument. ii. Daily use a clean cloth and a good non-abrasive cleaner to clean the stainless steel body of the griddle is recommended. Wipe the polished front with a soft cloth so not to scratch the finish. iii. At least once a day, remove the grease drawer and wash it using the same process as an ordinary cooking utensil. The drawer is removed by pulling forward until it is released from its track. SEASONING THE GRIDDLE HEATING SURFACE After the griddle has been thoroughly cleaned, it should be seasoned to prevent food from sticking. Before using and after each thorough scouring, season the griddle heating surface in the following manner. i. Turn the temperature control dials to 0 F ( C). ii. Using a clean cloth, not a spatula, spread a thin film of cooking oil over the griddle cooking surface. This film should remain on the hot griddle surface for half an hour. iii. Remove the excess oil and wipe clean. iv. Apply another film of cooking oil over the hot cooking area for another half hour and again remove excess oil and wipe clean. The griddle surface should now be ready for use. TEMPERATURE CONTROL SNAP-ACTION THERMOSTAT To power on the elements, turn the adjustment knob to the desired temperature. Turning the dial knob automatically maintains the selected heat range. There is one thermostat for every twelve [] inch (0 mm) wide section that operate independently. SELECTRONIC SOLID STATE To power on the elements, flip the switch corresponding to each section you wish to use to the ON position. Next, Turn the adjustment knob to the desired temperature [this system adjusts in increments of F ( C)]. COOKING Set the thermostat dial knob at the desired temperature. After a short pre-heating period, the thermostat will automatically maintain the selected temperature. IDLING During idle periods, to save on operating costs, lower the temperature setting of the thermostat to about 0 F ( C). It is not necessary to maintain cooking temperature during idle periods, as the griddle can quickly be reheated to the desired temperature. M-Z Rev C Owner s Manual for Lang xx-series Electric Griddles

SPECIFICATIONS T shown A. in. (0 mm) in. (0 mm) in. ( mm). in. (0 mm). in. ( mm). in. (0 mm) 0. in. ( mm) in. (0 mm) ELECTRICAL CONNECTION models. inches ( mm) from either side and models. inches ( mm) from right side 0 and models two [] connections, one. inches ( mm) from the right and one. inches ( mm) from the left. 0. in. ( mm) MODEL 0 HEIGHT in. ( mm) in. ( mm) in. ( mm) in. ( mm) in. ( mm). in. ( mm) WIDTH [A] in. (0 mm) in. ( mm) in. (. m) 0 in. (. m) in. (. m) DEPTH VOLTAGE kw Φ 0. in. ( mm) 0. in. ( mm) 0. in. ( mm) 0. in. ( mm) 0. in. ( mm) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 CLEARANCE Requires two electrical connections, noted as C for connection one [] and C as connection two []. These models are not CSA/cUL certified. 0 There must be at least one [] inch ( mm) of clearance between the sides and back of the unit and a wall.. 0 N/A. N/A. 00 N/A Φ L 0. 0.. Φ L. 0.. C same as C same as C same as C same as Φ L. 0. 0. APPROX. SHIP WEIGHT 0 lb. (. kg) lb. (. kg) 0 lb. (. kg) lb. (. kg) lb. ( kg) APPROX. WEIGHT INSTALLED 0 lb. (. kg) 0 lb. (. kg) 0 lb. (. kg) 0 lb. ( kg) 0 lb. (0. kg) 0 and models are not cul/csa certified

EXPLODED VIEW shown A B B 0 A A 0 0 M-Z Rev C Owner s Manual for Lang xx-series Electric Griddles

PARTS LIST Side references are from the operator s point-of-view from the front of the unit. All parts apply to chrome modelsalso except number, which has chrome or standard steel versions noted. Items labeled NP are not pictured. REF NO MODEL PART NUMBER QTY DESCRIPTION PAGE NO A B T, S K-EZG- T, S K-EZG-0 T, S K-EZG- 0T, 0S K-EZG- T, S K-EZG- TC, SC TC, SC TC, SC 0TC, 0SC TC, SC T/S K-EZG- K-EZG- K-EZG- K-EZG- K-EZG- T/S T/S N-00-0T/0S T/S T/S T/S T/S N-00-0 0T/0S T/S T/S T/S T/S K-XL- 0T/0S T/S T/S T/S T/S K-XL- 0T/0S T/S T/S T/S T/S K-XL- 0T/0S T/S griddle plate main element perimeter element element pan plate element retainer element pan 0

REF NO MODEL PART NUMBER QTY DESCRIPTION PAGE NO T/S K-EZG- T/S K-EZG- T/S K-EZG- body assembly 0T/0S K-EZG- T/S K-EZG-0 T/S G-Z T/S G-Z T/S G-Z rear panel 0T/0S G-Z T/S G-Z T E-000-0 pole terminal block [element] S E-000-0 pole terminal block [element] T E-000- pole terminal block [element] S E-000-0 pole terminal block [element] T/S E-000- pole terminal block [element] E-000-0 pole terminal block [element] 0T E-000- pole terminal block [element] 0S E-000-0 pole terminal block [element] E-000-0 pole terminal block [element] T E-000- pole terminal block [element] S E-000-0 pole terminal block [element] T/S T/S T/S E-000-0 pole terminal block [main power] 0T/0S T/S T/S T/S 0 T/S E-00-0 ground lug 0T/0S T/S ALL M-00- Lang badge ALL R-Z leg T/S T/S T/S G-Z grease drawer slide/cover 0T/0S T/S M-Z Rev C Owner s Manual for Lang xx-series Electric Griddles

REF NO MODEL PART NUMBER QTY DESCRIPTION PAGE NO 0 T/S T/S T/S C- 0 0T/0S T/S T/S T/S T/S G-0 0T/0S T/S T/S G-Z. in. (0 mm) wide bottom panel T/S T/S 0T/0S T/S G-Z. in. (0 mm) wide bottom panel G-Z. in. ( mm) wide bottom panel G-Z. in. (0 mm) wide bottom panel G-Z0. in. ( mm) wide bottom panel G-Z. in. (0 mm) wide bottom panel G-Z in. ( mm) wide bottom panel G-Z. in. (0 mm) wide bottom panel G-Z 0 in. (,0 mm) wide bottom panel S E-00-0 pole terminal block S E-00-0 pole terminal block S E-00-0 pole terminal block 0S E-00-0 pole terminal block E-00-0 pole terminal block S E-00-0 pole terminal block S C-00-0 S C-00-0 S C-00-0 0S C-00-0 S C-00-0 S, S, S, 0S, S S #- screw grease drawer #0 screw E-00-0 transformer S S E-00-0 0S S contactor? K-00-0?

REF NO MODEL PART NUMBER QTY DESCRIPTION PAGE NO ALL M-Z0 nameplate mount S S S E-00-W control board 0S S T/S T/S T/S C-00-0 tinnerman clip 0T/0S T/S S S A S E-00- control switch 0S S T T B T T-00-0 thermostat 0T T T/S T/S T/S C-00-0 0 tinnerman speed nut 0T/0S T/S T K-Z00 T K-Z0 T K-Z0 0T K-Z0 T K-Z0 S K-Z front panel S K-Z S K-Z 0S K-Z S K-Z M-Z Rev C Owner s Manual for Lang xx-series Electric Griddles

REF NO MODEL PART NUMBER QTY DESCRIPTION PAGE NO 0 T T T 0T T Y-0-0- S S S 0S S T T T R-Z 0T T S S S R-Z 0S S T T T K-EZG- 0T T S S S K-EZG- 0S S S S S E-00-0 0S S S, S, S, 0S, S S, S, S, 0S, S pilot/signal lamp die cast bezel knob assembly on/off switch plate I-0-0-00 switch boot M-Z main power on/off label

REF NO MODEL PART NUMBER QTY DESCRIPTION PAGE NO S, S, S, 0S, S S Z-0-0-0 main power switch guard S S E-00-0 0S S toggle switch M-Z Rev C Owner s Manual for Lang xx-series Electric Griddles

LANG MANUFACTURING www.langworld.com Hobson Street Smithville, Tennessee Telephone Fax Printed in the U.S.A. M-Z Rev C 0.0 Specifications are subject to change without notice.