Available online at ScienceDirect. Procedia Engineering 84 (2014 )

Similar documents
Available online at ScienceDirect. Procedia Engineering 135 (2016 )

Simulation of Full-scale Smoke Control in Atrium

Performance-based Fire Design of Air-supported Membrane Coal Storage Shed

Full-scale Experiment of Longitudinal Ventilation Smoke Control System and Central Smoke Exhaust System in City Underwater Tunnel

2012 International Symposium on Safety Science and Technology Factor analysis of high-rise building fires reasons and fire protection measures

A study of Transient Performance of A Cascade Heat Pump System

Procedia - Social and Behavioral Sciences 195 ( 2015 ) World Conference on Technology, Innovation and Entrepreneurship

Available online at ScienceDirect. Energy Procedia 91 (2016 ) 35 41

A Numerical study of the Fire-extinguishing Performance of Water Mist in an Opening Machinery Space

Analysis of the influence of open door size on fire smoke diffusion law in protective engineering

Design of Humidity Monitoring System Based on Virtual Instrument

Two-Pipe Fiber Bragg grating Temperature Sensor Applied in Cable Trench and Cable Pit

ScienceDirect. Development progress of critical equipment in the CSNS cryogenic hydrogen system

2012 International Symposium on Safety Science and Technology Investigation on compressed air foams fire-extinguishing model for oil pan fire

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

A Study into the Standardization of Using Fire Detectors in Rail Vehicles for China

INDOOR HUMAN THERMAL COMFORT OPTIMAL CONTROL WITH DESICCANT WHEEL COOLING SYSTEM

Available online at ScienceDirect. Procedia Engineering 135 (2016 )

The Effect of Quantity of Salt on the Drying Characteristics of Fresh Noodles

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Evaluation on Combustion Characteristics of Finishing Materials for Exterior Walls

Study of Numerical Analysis on Smoke Exhaust Performance of Portable Smoke Exhaust Fan

Research on fire protection methods and a case study "Futurum"

Available online at ScienceDirect. Procedia Engineering 135 (2016 )

The Application of Double-deck Inorganic Composite Fire Resisting Shutters in Constructional Engineering Bai-Xia ZHOU*

ZONE MODEL VERIFICATION BY ELECTRIC HEATER

Available online at ScienceDirect. Procedia Engineering 62 (2013 ) Charles M Fleischmann a, *, ZhiJian Chen b

RADIATION BLOCKAGE EFFECTS BY WATER CURTAIN

ScienceDirect. The Undrained Shear Strength of Overconsolidated Clays

The Development of Fire Risk Assessment Method for Heritage Building

OPTIMIZATION OF VENTILATION MODE OF SMOKE CONTROL SYSTEM IN HIGH-RISE BUILDING FIRE

Simulation of Evacuation Process in a Supermarket with Cellular Automata

The empirical research on the consumers' willingness to participate in E-waste recycling with a points reward system

Smoldering Propagation Characteristics of Flexible Polyurethane Foam under Different Air Flow Rates

ASSESSMENT OF FIRE BEHAVIOUR OF TIMBER PARTITION MATERIALS WITH A ROOM CALORIMETER

Open Access Operation Modes and Energy Analysis of a New Ice-Storage Air- Conditioning System

Simulation study of evacuation in high-rise buildings

Available online at ScienceDirect. Energy Procedia 78 (2015 )

Ecological Landscape Planning and Design of an Urban Landscape Fringe Area: A Case Study of Yang an District of Jiande City

PRELIMINARY EXPERIMENTAL STUDY OF DOUBLE-SKINNED FAÇADE

An experimental study of the impact of tunnel suppression on tunnel ventilation

Available online at ScienceDirect. Physics Procedia 67 (2015 )

Yunyong P. Utiskul, Ph.D., P.E., CFEI

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

Available online at ScienceDirect. New Framework of Intelligent Evacuation System of Buildings

The Experimental Study and Simplified Model of. Water Mist Absorbing Heat Radiation

Available online at ScienceDirect. Energy Procedia 70 (2015 ) Yanjun Dai*, Xian Li, Ruzhu Wang

Recent BRANZFIRE enhancements and validation

Fire Dynamics Simulation and Evacuation for a Large Shopping Center (Mall), Part II, Evacuation Scenarios

ASSESSMENT OF TIMBER PARTITION MATERIALS WITH FIRE RETARDANTS WITH A ROOM CALORIMETER

Several Ideas on Fire Detecting Alarm for Power Supply and Distribution System

Heat transfer enhancement in an air process heater using semi-circular hollow baffles

NUMERICAL STUDIES ON BARE CABIN FIRES WITH OPERATION OF SMOKE EXTRACTION SYSTEM

Effect of Inclination Angle in Heat Pipe Performance Using Copper Nanofluid

Residential Building Walls and Environment in Amman, Jordan

FIRE DYNAMICS IN FAÇADE FIRE TESTS: Measurement, modeling and repeatability

Fire Situations and Prevention Measures of residential building

Hot Issues in Fire Engineering 28 February 2012

Numerical Simulation of Thermal Comfort Degree in Radiant Floor Cooling Room. Architecture, Beijing , China

A study for a fire spread mechanism of residential buildings with numerical modeling

Available online at ScienceDirect. Procedia Engineering 102 (2015 )

Construction of Wireless Fire Alarm System Based on ZigBee Technology

Test One: The Uncontrolled Compartment Fire

Passive fire protection. 6 Passive fire protection. 6.1 Fire compartmentation. Passive fire protection

EPSRC Research Project: Real Fires for the Safe Design of Tall Buildings

CFD Analysis of Fire Characteristics on Subway Junction Station

Fabrication and characterisation of slim flat vacuum panels suitable for solar applications

Experimental Study to Evaluate Smoke Stratification and Layer Height in Highly Ventilated Compartments

Fire safety engineering applied to high-rise building facades

Experimental Analysis of Open, Simple and Modified Greenhouse Dryers for Drying Potato Flakes under Forced Convection

Available online at ScienceDirect. Procedia Engineering 146 (2016 )

COMPARISON OF CFD MODELLING WITH FIRE TESTS Comparison of CFD Modelling with Results of Full Scale Compartment Fire Tests in a Residential Unit

13th COTA International Conference of Transportation Professionals (CICTP 2013)

PRELIMINARY STUDIES ON MECHANICAL SMOKE EXHAUSTS IN LARGE SPACE BUILDING FIRES

Fire propagation over combustible exterior facades exposed to intensified flame in Japan

Experimental Study on the Effects of Compression Parameters on Molding Quality of Dried Fish Floss

Challenges of Fire Fighting in Fire Engineered Built Environment

An Analysis of Compartment Fire and Induced Smoke Movement in Adjacent Corridor

Copy of article submitted to Fire Safety Engineering for publication January/February 2009

Thermodynamic analysis of air cycle refrigeration system for Chinese train air conditioning

Numerical investigation on the effect of channelled and unchannelled screens on smoke contamination in atriums upper balconies with open upstand

Development and Full-Scale Tests of a Water Mist System inside High Speed Trains

Fire Resistance - Implications for regulations and standards of the September 11th terrorist attacks on the world trade centre Tom Lennon, FRS, BRE

LAMINATION AND CHARACTERIZATION OF A POLYETHYLENETEREPHTHALATE FLEXIBLE MICRO HEAT PIPE

Influences of temperature of vapour-condenser and pressure in the vacuum chamber on the cooling rate during vacuum cooling

EVALUATION ON PERFORMANCE OF PHOTOELECTRIC SMOKE DETECTORS IN THE ZONE DETECTION SYSTEM

Structure Improvement and Flow Field Analysis of Condenser in Freeze drying Equipment

Available online at ScienceDirect. Procedia Engineering 89 (2014 )

2. Gas B. The column of hot gases, flames, and smoke rising above a fire; also called convection column, thermal updraft, or thermal column

Mathematical Modeling of Fires

FULL-SCALE FIRE TESTS OF A TWO-STORY CROSS-LAMINATED TIMBER STRUCTURE

Available online at Energy Procedia 6 (2011) MEDGREEN 2011-LB

DEVELOPMENT OF THE INFRARED INSTRUMENT FOR GAS DETECTION

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY

THE EFFECT OF HEAT LOAD ARRANGEMENT ON THE PERFORMANCE OF RADIANT PANELS

Fire Resistance Proficiency Testing of Gypsum/Steel-Stud Wall Assemblies. William L. Grosshandler 1

The study of sewage sludge thermo-drying efficiency

Anatomy of a Fire. Christopher Crivello, MSFPE, PE. Douglas Nadeau, MSFPE, PE, CFPS, LEED AP

Research on Evaluation of Fire Detection Algorithms

FIRES IN BUILDING & CONSTRUCTIONS

Transcription:

Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 84 (2014 ) 553 557 2014ISSST, 2014 International Symposium on Safety Science and Technology Research on fire endurance of tempered glass based on infrared imaging technology LI Mingxuan*, LU Guojian, HU Zhongri, MEI Xiujuan, LI Le,WANG Liping Sichuan Fire Research Institute of MPS, Chengdu, 610039, China Abstract The tempered glass is widely used in the buildings because of its good transparence and fire endurance under the protection of the sprinkler.the fire backdraft may occur under the good ventilation condition after the tempered glasses fall apart in fire, which can endanger the human evacuation and fire rescue. By the testing of the surface temperature of the tempered glass exposed to the building fire, the critical temperature of the glass fracture can be acquired and the basis for the prediction and prevention of the fracture of the tempered glass then can be provided, which is useful for the performance-based design of the fire safety. The infrared imaging equipment is firstly used in China for the research on the fire endurance of the tempered glass. 2014 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license Peer-review (http://creativecommons.org/licenses/by-nc-nd/3.0/). under responsibility of scientific committee of Beijing Institute of Technology. Peer-review under responsibility of scientific committee of Beijing Institute of Technology Keywords: tempered glass; fire endurance; infrared imaging technology; critical temperature 1. Introduction With the emergence of diversity of new architectural styles, new materials, and large volume buildings, the visual translucency and continuity are required in more and more buildings. So the traditional fire compartment, such as firewalls and fire-resistant rolling shutters are unable to meet such requirements, and more and more tempered glass are used in the doors, windows and fire compartment. The poor ventilation condition in the combustion chamber and the lack of oxygen may cause the extinguishing or smoldering of fire, however the good ventilation condition caused by the fractured glass may form the fire backdraft, which can endanger the fire fighters and occupants in the building. During the performance-based design of fire safety, the time and possibility of the * Corresponding author. Tel.: +0-086-028-875-11960; fax: +0-086-028-875-11960. E-mail address: robustlee@sohu.com 1877-7058 2014 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/3.0/). Peer-review under responsibility of scientific committee of Beijing Institute of Technology doi:10.1016/j.proeng.2014.10.467

554 Li Mingxuan et al. / Procedia Engineering 84 ( 2014 ) 553 557 glass fracture will greatly influence the smoke spread. Many researches on glass fracture have been done at home and abroad, but the fire fuel are almost the oil, the fire load is also low, and the glasses used in the test are almost in small size, which do not comply with the real building fire conditions. Thus, a mathematical algorithm for glass breakage prediction in the FDS is needed [1], and the full-scale test with the tempered glass is used to analyze the fire endurance of the tempered glass. Many tests of the fire endurance of the tempered glass with the sprinkler protection have been conducted in China [2,3], in which the integrity of the tempered glass can maintain for a long time. However, the tests for the fire endurance of the tempered glass without the protection of the sprinkler have seldom been done, and the efficiency of the protection of the sprinkler for the tempered glass needs to be further validated. 2. Experimental setup The testing room with the size of 10 m(l) 10 m(w) 5 m(h) for the full-scale test of the fire endurance of the tempered glass is located at the large-space testing building in Dujiangyan City. The two walls of the testing room are constructed of concrete block of 20cm thickness, the other two walls are formed by the tempered glass assembly with the aluminum columns, which is shown in Fig. 1. The facade A is composed of 5 aluminum columns and 4 tempered glass panes with the size of 2.5m(L) 5m(W) 0.012m(T). The facade B is composed of 6 aluminum frames and 5 tempered glass panes with the size of 2m(L) 5m(W) 0.012m(T). Each of the tempered glasses of facade B is protected by the window sprinklers installed at top of the tempered glass, and the activation temperature of the sprinkler is 68.The space between the tempered glass and the frame is filled with the fire sealant. The tests for the fire endurance of the tempered glass with or without the protection of the window sprinkler are analyzed respectively. And the mechanical ventilation system with the ventilation volume of 60m 3 /m 2.h is used in the combustion chamber, which complies with China s codes for building fire protection. The fresh air can be supplied into the combustion chamber through the door. At the center of the combustion chamber and near each of the tempered glass, the thermocouples are positioned at the height of 1.8 m, 3.5 m and 4.8 m from the ground separately, so the temperature of the gas, the tempered glass and the glass edges can be measured, which is shown in Fig. 2. Two infrared (IR) cameras are positioned 11 m away from the front of facade A, so the temperature distribution on both sides of the tempered glass can be recorded. For the better application, the highest Heat Release Rate(HRR) satisfies the requirements for the ordinary places, such as shopping mall, etc. with the reference to Technical Specification for Building Smoke Control [1]. The maximum fire load of the shopping mall with sprinkler protection can reach 4MW, while the fire load of public hall without any sprinkler protection can reach 8 MW. The fire sources are wood cribs, which have been calibrated by the cone calorimeter according to ISO9705 and SBI before the test [2]. Fig. 1. Testing room. Fig. 2. Tempered glass of Façade A. 3. Data analysis 3.1. Fire scenario I For the wood crib fire test of 4 MW, Fig. 3 shows the temperature rise of the tempered glass of façade A at 10

Li Mingxuan et al. / Procedia Engineering 84 ( 2014 ) 553 557 555 minutes after the ignition, in which the temperature is about 100 at 3 m height, and about 40 at 1m height. Fig. 4 shows the temperature rise of the tempered glass of façade A at 20 minutes after the ignition, in which the temperature is about 180 at 3 m height, and about 80 at 1m height. The temperature difference between the upper part and the lower part is great because of the smoke stratification. The gas temperature of the upper part is higher than that of the lower part, because the fresh air comes in from the outside, and the convection between the different smoke layers causes the different temperature distribution on the tempered glass. Fig. 5 shows the timedependent temperature of the tempered glass of façade A at 0.5 m 1.5 m 2.5 m and 3.5 m height during the test, and the temperature difference between the upper part and the lower part is not over than 100. Fig. 6 shows the temperature of the 4 points in the horizontal direction for façade A at 3 m height. It shows clearly that the temperature difference in the horizontal direction is not over than 20. It is shown in Fig. 3 and Fig. 4 that the surface temperature of the tempered glass exposed to the fire source is not obviously higher than that of the other part of the tempered glass [3], which demonstrates that the radiation is not the dominant factor for the temperature rise of the tempered glass. The integrity of the tempered glass maintains well during the test, and no glass fracture or collapse happens [4]. Fig. 3. Temperature distribution on glass 2 and glass 3 at 10 minutes. Fig. 4. Temperature distribution on glass 2 and glass3 at 20 minutes. Fig. 5. Time-dependent temperature of glass 2 at 4 different heights. Fig. 6. Time-dependent temperature of 4 points of glass 2. 3.2. Fire scenario For the wood crib fire test of 8 MW, Fig. 7 shows that the left upper part of the tempered glass 2 breaks at 540 seconds after the ignition, when the highest temperature on the unexposed side is 300 and the highest temperature on the exposed side reach 700,which are recorded by the thermocouples. The right upper part of the tempered glass 3 breaks at 660 seconds after the ignition, when the highest temperature on the unexposed side reaches 335 and the highest temperature on the exposed side reaches 650, which are recorded by the thermocouples. Fig. 8 shows that the lower part of the tempered glass 2 breaks at 680 seconds after the ignition, when the fracture temperature of the upper part on the unexposed side is 350 and the lower part temperature is 100, while the highest temperature of the upper part on the exposed side reaches 620, and the lower part temperature is 150, which shows the great temperature difference between the exposed side and the unexposed side. Fig. 9 shows the

556 Li Mingxuan et al. / Procedia Engineering 84 ( 2014 ) 553 557 time-dependent temperature of the tempered glass 2 at 0.5 m, 1.5 m, 2.5 m and 3.5 m height, and the temperature difference between the upper part and the lower part is around 200. Fig. 10 shows the time-dependent temperature of the tempered glassof 4 points in the horizontal direction at the 3m height, which clearly shows that the temperature difference in the horizontal direction is narrow. 4. Results Through the full-scaled fire tests of 4 MW and 8 MW, the integrity of the tempered glass used in the shopping malls and public buildings without any protection of window sprinkler is studied, the temperature distribution on the tempered glass is measured, the different temperatures of the glass fracture are recorded and the following results are included: (1) The infrared camera(ir) can be used to record the surface temperature of the tempered glass during the whole test, so the thermocouple installation may be reduced, but the calibration with the thermocouple shall be carried out before the test. (2) The temperature of the upper part of the tempered glass is higher than that of the lower part because of the smoke stratification [5], which shows that the convection has more influence on the temperature rise than the radiation. Because the tempered glass has no good heat conductivity, the strain caused by the temperature difference is the key factor leading to the glass breakage. (3) The tempered glass maintains good integrity in the wood crib fire test of 4 MW, which demonstrates that the tempered glass used as the compartment item is reliable in the shopping mall under the sprinkler protection [6]. (4) The tempered glass does not maintain the integrity well in the wood crib fire testof 8MW without any sprinkler protection, and the temperature difference between the exposed side and the unexposed side when the tempered glass cracks, is about 300. So the tempered glass can be used as fire compartment item only when the reliable window sprinkler is used. (5) The tempered glass of facade B maintains good integrity in the tests, which demonstrates the effectiveness of the sprinkler protection. Fig. 7. Temperature distribution on glass 2 and glass 3 at 540 seconds. Fig. 8. Temperature distribution on glass 2 and glass 3 at 680 seconds. Fig. 9. Time-dependent temperature of glass 2 at 4 different heights. Fig. 10. Time-dependent temperature of 4 horizontal points on glass 2.

Li Mingxuan et al. / Procedia Engineering 84 ( 2014 ) 553 557 557 5. Conclusions and future works The traditional fire compartment items such as fire wall, fire-resistant rolling shutter, etc. are not characterized with transparence, which can t meet the needs of the building designers and owners. The testing results show that the tempered glass can be used as the fire compartment item under the sprinkler protection. However, the relationship between the temperature difference and the thermal strain of the heated tempered glass should be studied in the future research to set up the mathematical model for the prediction of the tempered glass breakage in the building fire. Acknowledgement This research project is funded by Twelfth Five-Year National Science and Technology Research Program (Grant No.2011BAK03B01). References [1] Li Mingxuan, Lu Guojian. Full-scale experimental study on tempered glass endurance under fire exposure. Fire Science and Technology, 2013, 32(5): 493-496. [2] Mei Xiujuan, Zhang Zejiang. Experiment study on single tempered glass with protection of sprinkler as fire compartmentation item. Fire science and technology, 2007, 26(5): 500-502. [3] N.D. Pope, C.G. Bailey. Development of a Gaussian glass breakage model within a fire field model. Fire Safety Journal, 2007, 42(7):366 376. [4] Li Jianhua, Zheng Huanghua. Study on Break behavior of common window glass. Fire Science. 1999, 3(8): 21-23. [5] Sarah Mladenka, Walter Romero,ChrisYeldell,Ofodike, Ezekoye, MichaelE. Cournoyer. Chemical hood glass failure under thermal loading associated with fire. Journal of Chemical Health&Safety, 2012: 11-13. [6] Chan-Wei Wu, Ta-Hui Lin. Full-scale evaluations on heat resistance of glass panes incorporated with water film or sprinkler in a room fire. Building and Environment, 2007, 42(8): 3277 3284.