Product Data. 24ACB7 Performancet Stage Air Conditioner with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS

Similar documents
Product Data. 24ACB7 Performancet 2---Stage Air Conditioner with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. INDUSTRY LEADING FEATURES / BENEFITS Efficiency S S S Sound S S S S Comfort S

Product Data. CA16NW Single---Stage Air Conditioner with Puronr Refrigerant /2 To 5 Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 24AAA5 Single---Stage Air Conditioner with Puronr Refrigerant /2 To 5 Tons INDUSTRY LEADING FEATURES / BENEFITS.

Product Data INDUSTRY LEADING FEATURES / BENEFITS MODEL 126CNA PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1-1/2 TO 5 NOMINAL TONS

Product Data. Efficiency S. S S Indoor air quality accessories available Comfort S System supports Edger Thermidistatt or standard

INDUSTRY LEADING FEATURES 1-1/2 5 / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS. BA15NA SINGLE -STAGE AIR -CONDITIONER WITH PURONr REFRIGERANT 1-1/2 TO 5 TONS.

Product Data. CA14NA Single---Stage Air Conditioner with Puronr Refrigerant /2 To 5 Tons INDUSTRY LEADING FEATURES / BENEFITS.

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 113A LegacytLine 13 Air Conditioner with Puronr Refrigerant 1-1/2 to 5 Nominal Tons (Sizes )

Product Data INDUSTRY LEADING FEATURES / BENEFITS MODEL 126B PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1-1/2 TO 5 NOMINAL TONS

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S.

Product Data. 25HCB6 Performancet Stage Heat Pump with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS.

Product Data. Efficiency S S S Sound S Comfort S. S S S S S S Durability. WeatherArmort protection package: S S S

SERIES 15 HEAT PUMP WITH PURON

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS.

Product Data. 24ABC6 Comfortt16 Air Conditioner with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Installation Instructions

Product Data. Efficiency

Product Data. 24AHA4 Performance Series Air Conditioner with Puron Refrigerant 1-1/2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 116B Legacyt Line 16 Air Conditioner with Puronr Refrigerant 1-1/2 to 5 Nominal Tons

Product Data. Model 113A Legacy-RNC Series Air Conditioner with Puronr INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S

Nominal Capacity /2Ton 024 2Tons /2Tons 036 3Tons /2Tons 048 4Ton 060 5Ton

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Product Data. Efficiency

R4H4. Product Specifications

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS.

Product Data INDUSTRY LEADING FEATURES / BENEFITS MODEL 126B PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1 1/2 TO 5 NOMINAL TONS

N4H4. Product Specifications

INDUSTRY LEADING FEATURES 2 5 / BENEFITS

N4A6. Product Specifications

R4H4. Product Specifications

Product Data. Efficiency

Product Data. Efficiency

Product Data. S Sound level as low as 67 dba Comfort. S System supports Thermidistatt or standard thermostat controls Reliability

A 14 SEER Heat Pump with R---410A Refrigerant Series

Product Data. Efficiency. S S Reliability

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

Product Data. 224ANS PREFERREDt SERIES HEAT PUMP WITH PURONr REFRIGERANT 1-1/2 TO 5 NOMINAL TONS INDUSTRY LEADING FEATURES / BENEFITS

Product Data. S Up to 20.5 SEER / 15.5 EER S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound

WCH5**4. Product Specifications

Product Data PA13NA PA13PA FEATURES AND BENEFITS

Product Data. Efficiency

Product Data INDUSTRY LEADING FEATURES / BENEFITS. BH13NA SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT. Efficiency S S Reliability S

Advance Product Data

Advance Product Data

Product Data. 24ABA3 Baset13 Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S

Product Data. Efficiency

Advance Product Data

Product Data. controls Reliability S Puronr refrigerant - environmentally sound, won t

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data. 38CKD (60 Hz) 13 SEER Air Conditioner Sizes FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data. 38QRR Performancet Series Heat Pump with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

R 410A Ducted Horizontal Air Conditioner. Model Number Voltage Size (tons) Nominal Btu/hr Operating Weight lbs (kg) HC4A318AKA

Product Data. 38CKS (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 AVAILABLE OPTIONS

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40QAC / 38HDR 40QAQ / 38QRR Ceiling---Suspended Duct Free Split System Sizes 018 to 060

Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 FEATURES

R 410A Ducted Horizontal Air Conditioner

Advance Product Data

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 24ANB1 Infinityr Stage Air Conditioner with Puronr Refrigerant 2to5NominalTons

Product Data. 38CKC 50 Hz Air Conditioner. Sizes 018 thru 060 FEATURES

PAJ3. Product Specifications

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

WCA3**4. Product Specifications

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MVC / 38MVC 40MVQ / 38MVQ High---Wall Duct Free Split System Sizes 009 to 024

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MKCB / 24AHA4 / 124ANS 40MKQB / 25HHA4 / 224ANS High---Wall Ductless Split System Sizes 18 to 32

Product Data. 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes ( /2 to 5 Nominal Tons) FEATURES AND BENEFITS.

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT

PAR5. Product Specifications

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MKCC / 24AHA4 / 124ANS 40MKQC / 25HHA4 / 224ANS Cassette Ductless Split System Sizes 18 to 34

Product Data. Fig. 1 - Unit 50VR -A

Product Data. Fig. 1 - Unit 50VG -A

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Product Data PA13 AIR CONDITIONER 1 AND 3 PHASE 1-1/2-5 TONS ( ) FEATURES AND BENEFITS AVAILABLE SIZES:

Model PA10 ELECTRIC AIR CONDITIONER SS-PA10-06 FEATURES. coated for a long-lasting, rustresistant,

WJH4 Product Specifications

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Product Data. 38YCC 50 Hz Heat Pump. Sizes 024 thru 060 FEATURES/BENEFITS

PHD3. Product Specifications

14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS 208/ , Single Phase

Product Data. 50ZPB Single---Packaged Air Conditioner System With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes )

SPLIT-SYSTEM HEAT PUMP UNIT. Model PH12 SS-PH12-11 FEATURES

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Product Data. PA4Z SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES )

Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner. Sizes 018 thru 060 FEATURES

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

Product Data PA3Z- B SINGLE- PACKAGED AIR CONDITIONER SYSTEM WITH R- 410A REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES )

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Submittal Data 558F SINGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNITS NOMINAL TONS DESCRIPTION FEATURES

Commercial High-Efficiency Condensing Units

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

10 SEER SPLIT-SYSTEM HEAT PUMP UNIT. Model PH10 SS-PH10-05 FEATURES

TECHNICAL SPECIFICATIONS

Product Data PF4MNP FAN COIL SIZES 018 THRU 060 STANDARD FEATURES AIR HANDLER TECHNOLOGY AT ITS FINEST

Transcription:

24ACB7 Performancet 17 2---tage Air Conditioner with r Refrigerant 2to5Tons Product Data Carrier Air Conditioners with r refrigerant provide a collection of features unmatched by any other family of equipment. The 24ACB has been designed utilizing Carrier s refrigerant. The environmentally sound refrigerant allows you to make a responsible decision in the protection of the earth s ozone layer. This product has been designed and manufactured to meet Energy tarr criteria for energy efficiency when matched with appropriate coil components. Refer to the combination ratings in the Product Data for system combinations that meet Energy tarr guidelines. NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI directory (www.ahridirectory.org) for the most up -to -date ratings information. INDUTRY LEADING FEATURE / BENEFIT Efficiency ound Comfort Up to 17.7 EER / Up to 13.7 EER Microtube Technologyt refrigeration system Indoor air quality accessories available ound level as low as 72 dba ystem supports Thermidistatt or standard 2 -stage thermostat controls Reliability Durability r refrigerant - environmentally sound, won t deplete the ozone layer and low lifetime service cost. Front -seating service valves 2 -stage scroll compressor Internal pressure relief valve Internal thermal overload Low pressure switch High pressure switch Filter drier Balanced refrigeration system for maximum reliability WeatherArmor Ultrat protection package: Applications olid, Durable sheet metal construction teel louver coil guard Baked -on, complete outer coverage, powder paint Long -line - up to 250 feet (76.2 m) total equivalent length, up to 200 feet (60.96 m) condenser above evaporator, or up to 80 ft. (24.38 m) evaporator above condenser (ee Longline Guide for more information.) Low ambient cooling (down to 0_F / -17.8_C ) with approved low ambient accessory kits.

MODEL NUMBER NOMENCLATURE 1 2 3 4 5 6 7 8 9 10 11 12 13 N N A A A/N N N N A/N A/N A/N N N 2 4 A C B 7 3 6 A 0 0 3 0 Product eries Product Family Tier 24=AC A=RE AC C=Performance Major eries EER 7=17 EER Cooling Capacity Variations Design Variation Not Defined Voltage A=tandard 3=208---230---1 Minor eries 0, 1, 2... Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program For verification of certification for individual products, go to www.ahridirectory.org. This product has been designed and manufactured to meet Energy tar criteria for energy efficiency when matched with appropriate coil components. However, proper refrigerant charge and proper air flow are critical to achieve rated capacity and efficiency. Installation of this product should follow all manufacturing refrigerant charging and air flow instructions. Failure to confirm proper charge and air flow may reduce energy efficiency and shorten equipment life. FEATURE TANDARD FEATURE Unit ize --- eries 24---31 36---31 48---31 60---32 Refrigerant X X X X Maximum EER Rating* 17.0 17.7 17.0 16.0 2---tage croll Compressor X X X X Low Ambient Cooling Capability with Approved Kits X X X X Crankcase Heater w/temperature witch O O X X Louvered Coil Guard X X X X FieldInstalledFilterDrier X X X X Front eating ervice Valves X X X X Internal Pressure Relief Valve X X X X Internal Thermal Overload X X X X Long Line capability X X X X Low Pressure witch X X X X High Pressure witch X X X X X = tandard O = Accessory * With approved combinations 2

REFRIGERANT PIPING LENGTH LIMITATION Liquid Line izing and Maximum Total Equivalent Lengths { for Cooling Only ystems with r Refrigerant: The maximum allowable length of a residential split system depends on the liquid line diameter and vertical separation between indoor and outdoor units. ee Table below for liquid line sizing and maximum lengths : ize 024 AC with 036 AC with 048 AC with 060 AC with Liquid Line Connection 3/8 3/8 Liquid Line Diam. w/txv 0 --- 5 (0---1.5) Maximum Total Equivalent Length Outdoor Unit BELOW Indoor Unit AC with Refrigerant Maximum Total Equivalent Length{: Outdoor unit BELOW Indoor Vertical eparation ft (m) 6 --- 10 (1.8---3.0) 11---20 (3.4---6.1) 21---30 (6.4---9.1) 31---40 (9.4---12.2) 41---50 (12.5---15.2) 51---60 (15.5---18.3) 61---70 (18.6---21.3) 71---80 (21.6---24.4) 1/4 75 75 75 50 50 --- --- --- --- --- --- --- --- 5/16 250* 250* 250* 250* 250* 225* 175 125 100 3/8 250* 250* 250* 250* 250* 250* 250* 250* 250* 5/16 175 150 150 100 100 100 75 --- --- --- --- 3//8 250* 250* 250* 250* 250* 250* 250* 250* 250* 3/8 3/8 250* 250* 250* 250* 250* 250* 230 160 --- --- 3/8 3/8 250* 250* 250* 225* 190 150 110 --- --- --- --- * Maximum actual length not to exceed 200 ft (61 m) { Total equivalent length accounts for losses due to elbows or fitting. ee the Long Line Guideline for details. --- --- = outside acceptable range ize 024 AC with 036 AC with 048 AC with 060 AC with Liquid Line Connection 3/8 3/8 Liquid Line Diam. w/txv 25 (7.6) Maximum Total Equivalent Length Outdoor Unit ABOVE Indoor Unit AC with Refrigerant Maximum Total Equivalent Length{: Outdoor unit ABOVE Indoor Vertical eparation ft (m) 26---50 (7.9---15.2) 51---75 (15.5---22.9) 76---100 (23.2---30.5) 101---125 (30.8---38.1) 126---150 (38.4---45.7) 151---175 (46.0---53.3) 176---200 (53.6---61.0) 1/4 100 125 175 200 225* 250* 250* 250* 5/16 250* 250* 250* 250* 250* 250* 250* 250* 3/8 250* 250* 250* 250* 250* 250* 250* 250* 5/16 225* 250* 250* 250* 250* 250* 250* 250* 3/8 250* 250* 250* 250* 250* 250* 250* 250* 3/8 3/8 250* 250* 250* 250* 250* 250* 250* 250* 3/8 3/8 250* 250* 250* 250* 250* 250* 250* 250* * Maximum actual length not to exceed 200 ft (61 m) { Total equivalent length accounts for losses due to elbows or fitting. ee the Long Line Guideline for details. REFRIGERANT CHARGE ADJUTMENT Liquid Line ize Charge oz/ft (g/m) 0.60 (17.74) 3/8 (Factory charge for lineset = 9 oz / 266.16 g) 5/16 0.40 (11.83) 1/4 0.27 (7.98) Units are factory charged for 15 ft (4.6 m) of 3/8 liquid line. The factory charge for 3/8 lineset 9 oz.(266.16 g). When using other length or diameter liquid lines, charge adjustments are required per the chart above. Charging Formula: [(Lineset oz/ft x total length) (factory charge for lineset)] = charge adjustment Example 1: ystem has 15 ft of line set using existing 1/4 liquid line. What charge adjustment is required? Formula: (.27 oz/ft x 15ft) (9 oz) = (-4.95) oz. Net result is to remove 4.95 oz of refrigerant from the system Example 2: ystem has 45 ft of existing 5/16 liquid line. What is the charge adjustment? Formula: (.40 oz/ft. x 45ft) (9 oz.) = 9 oz. Net result is to add 9 oz of refrigerant to the system NOTE: Conditions must be favorable for charging by subcooling method. Indoor temperature must be 70_F to80_f (21.1_C to 26.7_C), and outdoor temperature must be 70_F to 100_F (21.1_C to 37.8_C). If outside these conditions, adjust charge for long line sets by weigh -in method. 3

LONG LINE APPLICATION An application is considered Long Line, when the refrigerant level in the system requires the use of accessories to maintain acceptable refrigerant management for systems reliability. ee Accessory Usage Guideline table for required accessories. Defining a system as long line depends on the liquid line diameter, actual length of the tubing, and vertical separation between the indoor and outdoor units. For Air Conditioner systems, the chart below shows when an application is considered Long Line. For Air Conditioner systems, the chart below shows when an application is considered Long Line. AC with r Refrigerant Long Line Description ft (m) Beyond these lengths, a TXV is required Total Length Outdoor Unit Above or Below Indoor Unit TXV required beyond 50 ft. (15.2 m) TXV required beyond 20 ft. (6.1 m) AC with r Refrigerant Long Line Description ft (m) (Beyond these lengths, long line accessories are required) Liquid Line ize Units On ame Level Outdoor Below Indoor Outdoor Above Indoor 1/4 + TXV No accessories needed within allowed lengths allowed lengths No accessories needed within 175 (53.3) 5/16 + TXV 120 (36.6) 50 (15.2) vertical or 120 (36.6) total 120 (36.6) 3/8 + TXV 80 (24.4) 35 (10.7) vertical or 80 (24.4) total 80 (24.4) Note: ee Residential Piping and Long Line Guideline for details VAPOR LINE IZING AND COOLING CAPACITY LO Acceptable vapor line diameters provide adequate oil return to the compressor while avoiding excessive capacity loss. The suction line diameters shown in the chart below are acceptable for AC systems with refrigerant: Unit Nominal ize (Btuh) Vapor Line izing and Cooling Capacity Losses r Refrigerant 2 -tage Air Conditioner Applications Maximum Liquid Line Diameters (In. OD) Vapor Line Diameters (In.) OD 26---50 (7.9---15.2) 51---80 (15.5---24.4) 81---100 (24.7---30.5) Cooling Capacity Loss (%) Total Equivalent Line Length ft. (m) 101---125 (30.8---38.1) 126---150 (38.4---45.7) 151---175 (46.0---50.3) 176---200 (53.6---60.0) 201---225 (61.3---68.6) 024 5/8 0 1 1 2 3 3 4 4 5 2 --- tage 3/8 3/4 0 0 0 0 1 1 1 1 1 AC 036 5/8 1 2 4 5 6 7 9 10 11 2 --- tage 3/8 3/4 0 0 1 1 2 2 3 3 4 AC 7/8 0 0 0 0 1 1 1 1 2 048 3/4 1 2 2 3 4 5 6 7 7 2 --- tage 3/8 7/8 0 1 1 2 2 2 3 3 3 AC 1 --- 1/8 0 0 060 3/4 1 2 4 5 6 7 9 10 11 2 --- tage 3/8 7/8 0 1 2 2 3 4 4 5 5 AC 1 --- 1/8 0 0 0 1 1 1 1 1 1 Applications in this area may be long line and may have height restrictions. ee the Residential Piping and Long Line Guideline. Applications in this area are not recommended due to insufficient oil return PHYICAL DATA UNIT IZE ERIE 24---31 36---31 48---31 60---32 Compressor Type Ultratech 2---tage croll REFRIGERANT (R---410A) Control TXV ( Hard hutoff) Charge lb (kg) 6.64 (3.01) 9.26 (4.20) 12.94 (5.87) 12.70 (5.76) COND FAN Propeller Type, Direct Drive Air Discharge Vertical Air Qty (CFM) 2481 3068 4700 4700 Motor HP 1/12 1/10 1/4 1/4 Motor RPM 800 825 825 825 COND COIL Face Area (q ft) 19.38 19.38 25.12 25.12 Fins per In. 25 20 20 20 Rows 1 2 2 2 Circuits 5 7 7 7 VALVECONNECT.(In.ID) Vapor 3/4 7/8 7/8 7/8 Liquid 3/8 REFRIGERANT TUBE (In. OD) Rated Vapor* 3/4 7/8 1 --- 1/8 1 --- 1/8 Liquid 3/8 *Units are rated with 25 ft (7.6 m) of lineset length. ee Vapor Line izing and Cooling Capacity Loss table when using other sizes and lengths of lineset. 226---250 (68.9---76.2) 4

ELECTRICAL DATA UNIT IZE --- ERIE 24---31 V/PH OPER VOLT* COMPR FAN MAX FUE{ MCA or MAX MIN LRA RLA FLA CKT BRK AMP 58.3 11.1 0.6 14.5 20 36---31 83.0 15.3 0.7 19.8 35 208---230/1 253 197 48---31 104.0 21.2 1.3 27.8 40 60---32 152.9 28.8 1.3 37.3 60 * Permissible limits of the voltage range at which the unit will operate satisfactorily { Time --- Delay fuse. FLA --- Full Load Amps LRA --- Locked Rotor Amps MCA --- Minimum Circuit Amps RLA ---RatedLoadAmps NOTE: Control circuit is 24---V on all units and requires external power source. Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection. Complies with 2010 requirements of AHRAE tandards 90.1 A-WEIGHTED OUND POWER LEVEL UNIT IZE---VOLTAGE,ERIE TANDARD TYPICAL OCTAVE BAND PECTRUM (dba, without tone adjustment) RATING (dba) 125 250 500 1000 4000 8000 24---31 73 --- High tage 49.0 58.0 66.5 69.5 61.0 57.5 74 --- Low tage 52.0 59.5 67.0 69.5 61.0 55.0 36---31 74 --- High tage 53.5 61.5 68.0 71.0 62.5 57.5 73 --- Low tage 54.0 61.5 67.5 68.0 63.0 56.0 48---31 74 --- High tage 54.5 59.5 67.0 68.0 60.0 53.5 72 --- Low tage 55.5 61.5 67.0 66.0 60.5 55.0 60---32 75 --- low stage 71.0 70.0 69.0 70.0 63.0 60.0 74 --- high stage 69.0 68.0 69.0 71.0 61.0 59.0 NOTE: Tested in accordance with AHRI tandard 270---08. (Not listed with AHRI). CHARGING UBCOOLING (TXV-TYPE EXPANION DEVICE) THERMOTAT UNIT IZE---VOLTAGE, ERIE REQUIRED UBCOOLING _F (_C) 24---31 10 (5.6) 36---31 14 (7.8) 48---31 13 (7.2) 60---32 14 (7.8) PART NUMBER PROGRAM GA ELECTRIC HEAT COOL Performance TP --- PAC01 7 --- Day 1 1 TP --- NAC01 NP 1 1 THERMOTAT ACCEORIE PART NUMBER BRIEF DECRIPTION THERMOTAT UED WITH YTXCCRR01 Indoor Remote Room Temperature ensor All TP --- thermostats TP --- EXP01 --- A ExP Computer Programming Accessory TP---P thermostats TTATXXCNV10 Thermostat Conversion Kit (4 to 5 wire) --- 10 pack All Carrier branded thermostats TX --- LBP01 LargeDecorativeBackplate TP --- Pxx, TP --- Nxx, TC --- Pxx TTATXXEN01---B Outdoor Air Temperature ensor All TP --- thermostats AvailablethroughRCD 5

ACCEORIE ORDER NUMBER DECRIPTION 24---31 36---31 48---31 60---32 KAACH1701AAA CRKC HTR KIT X X KAAL0201LL OL VALVE KIT X X X X KAAW0101AAA WINTER T KIT X X X X KAFT0101AAA FRZ THERM KIT X X X X KAH2501AAA HARD TART KIT X X KAH2801AAA HARD TART KIT X X KALA0301410 LOW AMBIENT KIT X X X X KAF0101AAA PRT FEET KIT X X X X KAH2301COP OUND BLKT KIT X X KAH2401COP OUND BLKT KIT X X X = Accessory = tandard * Not backward compatible to previous series. ACCEORY UAGE GUIDELINE Accessory Required for Low Ambient Cooling Applications (Below 55 F / 12.8 C) Required for Long Line Applications* Required for ea Coast Applications (within 2 miles/3.2 km) Compressor tart Assist Capacitor and Relay Yes Yes No Crankcase Heater Yes (standard on some units) Yes (standard on some units) No Evaporator Freeze Thermostat Yes No No Hard hutoff TXV Liquid Line olenoid Valve Yes (standard w/factory approved indoor unit) No Yes (standard w/factory approved indoor unit) ee Residential Piping and Long Line Guideline Yes (standard w/factory approved indoor unit) Low---Ambient Pressure witch Yes No No upport Feet Recommended No Recommended Winter tart Control Yes No No * For tubing line sets between 80 and 200 ft. (24.38 and 60.96 m) and/or 35 ft. (10.7 m) vertical differential, refer to Residential Piping and Longline Guideline. Accessory Description and Usage (Listed Alphabetically) 1. Compressor tart Assist - Capacitor and Relay tart capacitor and relay gives a hard boost to compressor motor at each start up. Usage Guideline: Required for 2 -stage non -communicating units in the following applications: - Long line - Low ambient cooling uggested for all compressors in areas with a history of low voltage problems. 2. Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance of liquid slugging. Usage Guideline: Required in low ambient cooling applications. Required in long line applications. uggested in all commercial applications. 3. Evaporator Freeze Thermostat An PT temperature-actuated switch that stops unit operation when evaporator reaches freeze -up conditions. Usage Guideline: Required when low ambient kit has been added. 4. Low -Ambient Pressure witch A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits. The control will maintain working head pressure at low -ambient temperatures down to 0_F (-17.8_C) when properly installed. Usage Guideline: A Low -Ambient Pressure witch must be used when cooling operation is used at outdoor temperatures below 55_F (12.8_C). 5. upport Feet Four stick -on plastic feet that raise the unit 4 in. (101.6 mm) above the mounting pad. This allows sand, dirt, and other debris to be flushed from the unit base, minimizing corrosion. Usage Guideline: uggested in the following applications: Coastal installations. Windy areas or where debris is normally circulating. Rooftop installations. For improved sound ratings. 6. Thermostatic Expansion Valve (TXV) A modulating flow -control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Kit includes valve, adapter tubes, and external equalizer tube. Hard shut off types are available. NOTE: When using a hard shut off TXV with single phase reciprocating compressors, a Compressor tart Assist Capacitor and Relay is required. Usage Guideline: Required to achieve AHRI ratings in certain equipment combinations. Refer to combination ratings. Hard shut off TXV or LL required in air conditioner long line applications. 7. Winter tart Control This control is designed to alleviate nuisance opening of the low -pressure switch by bypassing it for the first 3 minutes of operation. No 6

DIMENION 7

CLEARANCE Clearances (various examples) Wall Wall 24 ervice 6 (152.4 mm) 12 (304.8) 24 (609.6) ervice Wall 6 (152.4) 12 (304.8) 12 (304.8) 12 (304.8) Wall 24 (609.6) ervice 24 (609.6) ervice 24 (609.6) ervice A07833 24 (609.6) 24 (609.6) 24 (609.6) Note: Numbers in ( ) = mm IMPORTANT: When installing multiple units in an alcove, roof well, or partially enclosed area, ensure there is adequate ventilation to prevent re -circulation of discharge air. 8

TETED AHRI COMBINATION RATING NOTE: Ratings contained in this document are subject to change at any time. For AHRI ratings certificates, please refer to the AHRI directory www.ahridirectory.org Additional ratings and system combinations can be accessed via the Carrier database at: www.mycarrierratings.com For performance data at specific application &/or design conditions with various indoor unit combinations, the equipment performance calculator can be accessed at : http://rpmob.wrightsoft.com/ Outdoor Model Indoor Coil Model Furnace Model Cooling Capacity EER EER ID CFM HIGH LOW 24ACB724A**031 CNPV*3117AL* 58CV(A,X)090---16 24,000 13.0 17.0 835 670 24ACB736A**031 CNPV*4821AL* 58CV(A,X)090---16 36,000 13.0 17.0 1005 835 24ACB748A**031 CNPV*6124AL* 58CV(A,X)135---22 48,000 13.0 17.0 1355 1010 24ACB760AB*032 CAP**6124AL** --- --- 56,500 12.0 14.5 1625 1300 AHRI Air Conditioning, Heating & Refrigeration Institute EER Energy Efficiency Ratio --- 80_F (26.6_C) indoor db/67_f (19.4_C) indoor wb & 95_F (35_C) outdoor wb. EER easonal Energy Efficiency Ratio NOTE: 1. Ratings are net values reflecting the effects of circulating fan motor heat. upplemental electric heat is not included. 2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other combinations are determined under DOE computer simulation procedures. 3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature. 4. Do not apply with capillary tube coils as performance and reliability are affected. 9

DETAILED COOLING CAPACITIE# EVAPORATOR AIR CFM 600 650 700 750 800 835 900 EWB F( C) CONDENER ENTERING AIR TEMPERATURE F ( C) 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7) ystem ystem ystem ystem ystem ystem Total ens Total ens Total ens Total ens Total ens Total ens 24ACB724A*031 Outdoor ection With CNPV*3117A**+58CV(A,X)090---16 Indoor ection --- High 57 (13.9) 24.35 24.35 1.59 21.95 21.95 1.68 19.59 19.59 1.78 17.29 17.29 1.90 15.06 15.06 2.03 12.92 12.92 2.18 62 (16.7) 25.97 21.39 1.60 23.22 19.39 1.69 20.53 17.42 1.79 17.94 15.51 1.90 15.45 13.65 2.03 13.09 11.86 2.18 63 (17.2) 26.50 17.74 1.60 23.69 16.00 1.69 20.94 14.30 1.79 18.29 12.65 1.91 15.74 11.06 2.03 13.32 9.54 2.18 67 (19.4) 28.68 18.42 1.61 25.64 16.63 1.71 22.68 14.88 1.80 19.82 13.18 1.92 17.07 11.54 2.04 14.47 9.98 2.19 72 (22.2) 31.66 15.36 1.63 28.31 13.79 1.72 25.04 12.27 1.82 21.89 10.80 1.93 18.87 9.39 2.06 16.01 8.05 2.21 57 (13.9) 25.14 25.14 1.60 22.64 22.64 1.69 20.19 20.19 1.80 17.81 17.81 1.91 15.50 15.50 2.04 13.29 13.29 2.18 62 (16.7) 26.46 22.38 1.61 23.65 20.29 1.70 20.90 18.25 1.80 18.25 16.26 1.91 15.71 14.32 2.04 13.33 13.26 2.19 63 (17.2) 26.98 18.42 1.61 24.11 16.62 1.70 21.29 14.87 1.80 18.57 13.16 1.92 15.98 11.52 2.04 13.51 9.95 2.19 67 (19.4) 29.19 19.14 1.63 26.08 17.29 1.72 23.05 15.48 1.81 20.12 13.72 1.93 17.32 12.03 2.05 14.66 10.41 2.20 72 (22.2) 32.19 15.83 1.64 28.75 14.22 1.73 25.41 12.65 1.83 22.20 11.14 1.94 19.12 9.70 2.07 16.20 8.32 2.21 57 (13.9) 25.85 25.85 1.61 23.27 23.27 1.71 20.74 20.74 1.81 18.28 18.28 1.92 15.90 15.90 2.05 13.62 13.62 2.19 62 (16.7) 26.90 23.34 1.62 24.03 21.18 1.71 21.23 19.06 1.81 18.53 16.98 1.92 15.97 15.81 2.05 13.65 13.65 2.20 63 (17.2) 27.40 19.08 1.62 24.46 17.23 1.71 21.59 15.42 1.81 18.83 13.66 1.92 16.18 11.97 2.05 13.67 10.34 2.20 67 (19.4) 29.63 19.84 1.64 26.45 17.93 1.73 23.35 16.07 1.82 20.38 14.26 1.93 17.52 12.51 2.06 14.82 10.84 2.21 72 (22.2) 32.64 16.28 1.65 29.13 14.63 1.74 25.73 13.02 1.84 22.46 11.48 1.95 19.33 10.00 2.08 16.37 8.58 2.22 57 (13.9) 26.50 26.50 1.63 23.85 23.85 1.72 21.24 21.24 1.82 18.71 18.71 1.93 16.26 16.26 2.06 13.93 13.93 2.20 62 (16.7) 27.30 24.28 1.63 24.37 22.04 1.72 21.53 19.84 1.82 18.80 17.68 1.93 16.29 16.29 2.06 13.95 13.95 2.20 63 (17.2) 27.76 19.72 1.63 24.77 17.82 1.72 21.86 15.96 1.82 19.04 14.15 1.93 16.35 12.41 2.06 13.82 10.73 2.20 67 (19.4) 30.00 20.53 1.65 26.77 18.56 1.73 23.63 16.64 1.83 20.59 14.78 1.94 17.70 12.98 2.07 14.96 11.25 2.21 72 (22.2) 33.03 16.71 1.66 29.46 15.02 1.75 26.01 13.38 1.85 22.68 11.80 1.96 19.51 10.29 2.08 16.51 8.84 2.23 57 (13.9) 27.10 27.10 1.64 24.38 24.38 1.73 21.70 21.70 1.83 19.10 19.10 1.94 16.60 16.60 2.07 14.20 14.20 2.21 62 (16.7) 27.65 25.20 1.64 24.69 22.88 1.73 21.82 20.59 1.83 19.13 19.13 1.94 16.62 16.62 2.07 14.22 14.22 2.21 63 (17.2) 28.08 20.35 1.64 25.05 18.40 1.73 22.09 16.49 1.83 19.23 14.63 1.94 16.51 12.83 2.07 13.94 11.11 2.21 67 (19.4) 30.34 21.20 1.66 27.05 19.18 1.74 23.86 17.21 1.84 20.78 15.29 1.95 17.85 13.44 2.08 15.08 11.66 2.22 72 (22.2) 33.37 17.13 1.67 29.75 15.40 1.76 26.25 13.73 1.85 22.88 12.12 1.96 19.67 10.57 2.09 16.63 9.09 2.24 57 (13.9) 27.50 27.50 1.65 24.72 24.72 1.74 22.00 22.00 1.83 19.36 19.36 1.95 16.81 16.81 2.07 14.38 14.38 2.22 62 (16.7) 27.89 25.83 1.65 24.90 23.45 1.74 22.03 22.03 1.83 19.39 19.39 1.95 16.84 16.84 2.07 14.40 14.40 2.22 63 (17.2) 28.29 20.79 1.65 25.22 18.80 1.74 22.23 16.85 1.84 19.35 14.96 1.95 16.61 13.13 2.07 14.02 11.38 2.22 67 (19.4) 30.54 21.66 1.66 27.22 19.61 1.75 24.00 17.60 1.85 20.90 15.65 1.96 17.95 13.76 2.08 15.16 11.94 2.23 72 (22.2) 33.58 17.41 1.68 29.93 15.67 1.76 26.39 13.97 1.86 23.00 12.33 1.97 19.77 10.77 2.10 16.70 9.27 2.24 57 (13.9) 28.17 28.17 1.66 25.31 25.31 1.75 22.51 22.51 1.85 19.79 19.79 1.96 17.18 17.18 2.08 14.67 14.67 2.23 62 (16.7) 28.32 26.95 1.66 25.34 25.34 1.75 22.55 22.55 1.85 19.82 19.82 1.96 17.20 17.20 2.08 14.70 14.70 2.23 63 (17.2) 28.63 21.58 1.66 25.50 19.52 1.75 22.47 17.51 1.85 19.55 15.56 1.96 16.77 13.67 2.08 14.15 11.85 2.23 67 (19.4) 30.88 22.51 1.68 27.51 20.38 1.76 24.24 18.31 1.86 21.10 16.29 1.97 18.11 14.34 2.09 15.28 12.46 2.24 72 (22.2) 33.93 17.93 1.69 30.22 16.14 1.78 26.64 14.41 1.87 23.20 12.73 1.98 19.92 11.12 2.11 16.82 9.58 2.25 ee notes on page 14 10

DETAILED COOLING CAPACITIE# (CONTINUED) EVAPORATOR AIR CFM 450 500 550 600 650 670 700 EWB F( C) CONDENER ENTERING AIR TEMPERATURE F ( C) 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7) ys. ys. ys. ys. ys. ys. Total ens Total ens Total ens Total ens Total ens Total ens 24ACB724A*031 Outdoor ection With CNPV*3117A**+58CV(A,X)090---16 Indoor ection --- Low 57 (13.9) 17.62 17.62 1.05 16.16 16.16 1.25 14.68 14.68 1.48 13.20 13.20 1.76 11.79 11.79 2.07 10.43 10.43 2.44 62 (16.7) 18.73 15.76 1.04 17.00 14.15 1.24 15.27 12.56 1.48 13.57 11.03 1.75 11.95 9.57 2.07 10.46 10.45 2.44 63 (17.2) 19.10 13.04 1.04 17.34 11.64 1.24 15.56 10.27 1.47 13.83 8.95 1.75 12.16 7.70 2.07 10.58 6.53 2.44 67 (19.4) 20.70 13.55 1.02 18.79 12.11 1.22 16.89 10.70 1.46 15.02 9.35 1.73 13.24 8.06 2.06 11.55 6.85 2.43 72 (22.2) 22.95 11.31 1.00 20.84 10.04 1.20 18.74 8.82 1.44 16.71 7.65 1.71 14.76 6.54 2.04 12.91 5.51 2.42 57 (13.9) 18.38 18.38 1.05 16.84 16.84 1.25 15.28 15.28 1.48 13.74 13.74 1.75 12.25 12.25 2.07 10.84 10.84 2.44 62 (16.7) 19.20 16.75 1.04 17.41 15.05 1.24 15.63 13.38 1.48 13.90 11.76 1.75 12.28 12.28 2.07 10.85 10.85 2.44 63 (17.2) 19.56 13.72 1.04 17.73 12.26 1.24 15.90 10.83 1.48 14.11 9.45 1.75 12.40 8.15 2.07 10.78 6.92 2.44 67 (19.4) 21.19 14.29 1.02 19.21 12.78 1.22 17.25 11.30 1.46 15.33 9.89 1.74 13.49 8.54 2.06 11.76 7.27 2.44 72 (22.2) 23.47 11.79 1.00 21.29 10.47 1.20 19.13 9.20 1.44 17.03 7.99 1.72 15.02 6.85 2.05 13.12 5.78 2.43 57 (13.9) 19.06 19.06 1.05 17.44 17.44 1.25 15.81 15.81 1.48 14.21 14.21 1.75 12.66 12.66 2.07 11.19 11.19 2.44 62 (16.7) 19.60 17.71 1.04 17.77 15.93 1.24 15.96 14.17 1.48 14.23 14.23 1.75 12.68 12.68 2.07 11.21 11.21 2.45 63 (17.2) 19.94 14.38 1.04 18.06 12.86 1.24 16.18 11.37 1.48 14.34 9.94 1.75 12.59 8.58 2.08 10.94 7.29 2.45 67 (19.4) 21.60 15.00 1.02 19.57 13.42 1.22 17.55 11.89 1.46 15.58 10.42 1.74 13.70 9.01 2.06 11.93 7.68 2.44 72 (22.2) 23.90 12.24 1.00 21.66 10.89 1.20 19.44 9.57 1.44 17.29 8.32 1.72 15.24 7.14 2.05 13.30 6.04 2.43 57 (13.9) 19.66 19.66 1.05 17.98 17.98 1.25 16.28 16.28 1.48 14.62 14.62 1.75 13.02 13.02 2.08 11.50 11.50 2.45 62 (16.7) 19.96 18.65 1.04 18.11 16.78 1.24 16.31 16.31 1.48 14.65 14.65 1.75 13.04 13.04 2.08 11.52 11.52 2.45 63 (17.2) 20.26 15.03 1.04 18.33 13.45 1.24 16.41 11.90 1.48 14.54 10.42 1.76 12.76 9.00 2.08 11.08 7.67 2.45 67 (19.4) 21.94 15.69 1.03 19.86 14.06 1.23 17.80 12.47 1.46 15.79 10.93 1.74 13.88 9.47 2.07 12.08 8.09 2.45 72 (22.2) 24.26 12.68 1.00 21.96 11.29 1.20 19.70 9.94 1.44 17.50 8.65 1.72 15.41 7.44 2.06 13.44 6.30 2.44 57 (13.9) 20.20 20.20 1.05 18.46 18.46 1.25 16.71 16.71 1.48 15.00 15.00 1.76 13.35 13.35 2.08 11.78 11.78 2.45 62 (16.7) 20.31 19.56 1.05 18.49 18.49 1.25 16.74 16.74 1.48 15.02 15.02 1.76 13.37 13.37 2.08 11.80 11.80 2.45 63 (17.2) 20.54 15.66 1.05 18.58 14.03 1.25 16.62 12.42 1.48 14.72 10.89 1.76 12.90 9.42 2.09 11.21 8.03 2.46 67 (19.4) 22.24 16.37 1.03 20.11 14.68 1.23 18.01 13.03 1.47 15.97 11.44 1.75 14.03 9.92 2.07 12.21 8.48 2.45 72 (22.2) 24.57 13.12 1.00 22.22 11.68 1.20 19.91 10.29 1.44 17.68 8.97 1.73 15.56 7.72 2.06 13.56 6.54 2.45 57 (13.9) 20.41 20.41 1.05 18.64 18.64 1.25 16.87 16.87 1.48 15.14 15.14 1.76 13.47 13.47 2.08 11.88 11.88 2.46 62 (16.7) 20.46 20.36 1.05 18.67 18.67 1.25 16.90 16.90 1.48 15.16 15.16 1.76 13.49 13.49 2.08 11.90 11.90 2.46 63 (17.2) 20.64 15.91 1.05 18.66 14.25 1.25 16.69 12.63 1.48 14.78 11.07 1.76 12.96 9.58 2.09 11.26 8.17 2.46 67 (19.4) 22.34 16.64 1.03 20.20 14.92 1.23 18.09 13.25 1.47 16.04 11.64 1.75 14.09 10.10 2.08 12.26 8.64 2.45 72 (22.2) 24.67 13.29 1.01 22.31 11.84 1.21 19.99 10.43 1.45 17.75 9.09 1.73 15.61 7.83 2.06 13.60 6.64 2.45 57 (13.9) 20.70 20.70 1.05 18.90 18.90 1.25 17.10 17.10 1.48 15.34 15.34 1.76 13.64 13.64 2.08 12.03 12.03 2.46 62 (16.7) 20.73 20.73 1.05 18.93 18.93 1.25 17.13 17.13 1.48 15.36 15.36 1.76 13.66 13.66 2.08 12.05 12.05 2.46 63 (17.2) 20.79 16.28 1.05 18.79 14.59 1.25 16.80 12.94 1.49 14.87 11.35 1.77 13.04 9.83 2.09 11.33 8.38 2.47 67 (19.4) 22.49 17.03 1.03 20.33 15.28 1.23 18.20 13.58 1.47 16.13 11.93 1.75 14.16 10.36 2.08 12.33 8.87 2.46 72 (22.2) 24.82 13.53 1.01 22.44 12.06 1.21 20.10 10.64 1.45 17.84 9.28 1.73 15.69 7.99 2.07 13.66 6.78 2.45 ee notes on page 14 11

DETAILED COOLING CAPACITIE# (CONTINUED) EVAPORATOR AIR CFM 900 975 1005 1200 1350 720 780 835 960 1080 EWB F( C) CONDENER ENTERING AIR TEMPERATURE F ( C) 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7) ys. ys. ys. ys. ys. ys. Total ens Total ens Total ens Total ens Total ens Total ens 24ACB736A*031 Outdoor ection With CNPV*4821A**+58CV(A,X)090---16 Indoor ection --- High 57 (13.9) 35.84 35.84 2.28 33.31 33.31 2.47 30.78 30.78 2.70 28.23 28.23 2.96 25.63 25.63 3.26 22.99 22.99 3.58 62 (16.7) 38.02 31.58 2.30 35.06 29.75 2.49 32.11 27.93 2.72 29.14 26.10 2.97 26.15 24.26 3.26 23.16 22.40 3.58 63 (17.2) 38.77 26.12 2.30 35.74 24.49 2.50 32.71 22.86 2.72 29.66 21.22 2.98 26.58 19.58 3.27 23.48 17.94 3.58 67 (19.4) 41.84 27.07 2.33 38.59 25.41 2.52 35.31 23.74 2.74 32.02 22.07 3.00 28.69 20.39 3.29 25.34 18.71 3.60 72 (22.2) 46.07 22.49 2.37 42.48 20.99 2.56 38.88 19.49 2.77 35.25 17.98 3.03 31.59 16.46 3.31 27.88 14.95 3.63 57 (13.9) 36.91 36.91 2.30 34.29 34.29 2.50 31.67 31.67 2.73 29.01 29.01 2.99 26.31 26.31 3.28 23.57 23.57 3.60 62 (16.7) 38.68 32.98 2.32 35.66 31.09 2.51 32.63 29.20 2.74 29.60 27.31 2.99 26.56 25.39 3.28 23.61 23.61 3.60 63 (17.2) 39.40 27.07 2.32 36.30 25.40 2.52 33.20 23.73 2.74 30.07 22.04 3.00 26.93 20.36 3.28 23.76 18.68 3.60 67 (19.4) 42.51 28.10 2.35 39.17 26.38 2.54 35.82 24.67 2.76 32.44 22.95 3.02 29.04 21.23 3.30 25.62 19.50 3.62 72 (22.2) 46.76 23.13 2.40 43.10 21.60 2.58 39.41 20.07 2.79 35.69 18.53 3.04 31.95 16.98 3.33 28.17 15.43 3.64 57 (13.9) 37.31 37.31 2.31 34.65 34.65 2.51 31.99 31.99 2.74 29.30 29.30 2.99 26.56 26.56 3.28 23.78 23.78 3.60 62 (16.7) 38.93 33.53 2.33 35.87 31.61 2.52 32.83 29.70 2.74 29.77 27.78 3.00 26.72 25.82 3.29 23.82 23.82 3.60 63 (17.2) 39.63 27.45 2.33 36.51 25.76 2.52 33.38 24.06 2.75 30.22 22.37 3.00 27.05 20.67 3.29 23.85 18.96 3.60 67 (19.4) 42.75 28.49 2.36 39.37 26.76 2.55 36.00 25.03 2.77 32.59 23.29 3.02 29.17 21.56 3.31 25.71 19.81 3.62 72 (22.2) 47.01 23.39 2.40 43.32 21.84 2.58 39.60 20.29 2.80 35.85 18.74 3.05 32.08 17.18 3.34 28.27 15.62 3.65 57 (13.9) 39.58 39.58 2.37 36.72 36.72 2.56 33.84 33.84 2.79 30.92 30.92 3.04 27.97 27.97 3.33 24.98 24.98 3.65 62 (16.7) 40.28 36.94 2.38 37.11 34.86 2.57 33.98 32.74 2.79 30.97 30.97 3.04 28.01 28.01 3.33 25.01 25.01 3.65 63 (17.2) 40.84 29.78 2.38 37.56 27.98 2.57 34.29 26.19 2.79 31.00 24.39 3.04 27.69 22.59 3.33 24.38 20.78 3.64 67 (19.4) 44.00 30.99 2.41 40.46 29.14 2.59 36.93 27.31 2.81 33.39 25.47 3.07 29.82 23.62 3.35 26.24 21.77 3.66 72 (22.2) 48.33 24.94 2.45 44.46 23.32 2.63 40.57 21.70 2.84 36.66 20.07 3.09 32.73 18.44 3.38 28.78 16.81 3.69 57 (13.9) 41.01 41.01 2.41 38.01 38.01 2.60 34.98 34.98 2.82 31.93 31.93 3.08 28.84 28.84 3.37 25.70 25.70 3.68 62 (16.7) 41.19 39.34 2.41 38.05 38.05 2.60 35.03 35.03 2.82 31.97 31.97 3.08 28.88 28.88 3.37 25.73 25.73 3.68 63 (17.2) 41.54 31.48 2.42 38.18 29.61 2.60 34.82 27.74 2.82 31.44 25.87 3.07 28.06 23.99 3.36 24.68 22.09 3.67 67 (19.4) 44.70 32.80 2.45 41.09 30.89 2.63 37.47 28.98 2.85 33.83 27.06 3.10 30.19 25.13 3.38 26.53 23.19 3.69 72 (22.2) 49.07 26.06 2.49 45.10 24.39 2.67 41.11 22.71 2.88 37.11 21.04 3.12 33.08 19.36 3.41 29.04 17.68 3.72 24ACB736A*031 Outdoor ection With CNPV*4821A**+58CV(A,X)090---16 Indoor ection --- Low 57 (13.9) 26.16 26.16 1.51 24.56 24.56 1.75 22.93 22.93 2.02 21.26 21.26 2.34 19.53 19.53 2.71 17.74 17.74 3.15 62 (16.7) 27.22 23.86 1.51 25.33 21.80 1.74 23.44 19.77 2.02 21.51 17.78 2.34 19.57 19.55 2.71 17.77 17.77 3.15 63 (17.2) 27.75 19.50 1.50 25.81 17.73 1.74 23.86 15.99 2.01 21.86 14.30 2.34 19.80 12.63 2.71 17.68 11.01 3.15 67 (19.4) 30.15 20.35 1.48 28.03 18.51 1.72 25.90 16.71 2.00 23.75 14.95 2.32 21.53 13.24 2.70 19.24 11.56 3.13 72 (22.2) 33.42 16.77 1.46 31.06 15.17 1.70 28.71 13.59 1.98 26.32 12.07 2.30 23.88 10.60 2.67 21.37 9.16 3.10 57 (13.9) 26.97 26.97 1.52 25.30 25.30 1.75 23.60 23.60 2.02 21.87 21.87 2.34 20.07 20.07 2.72 18.21 18.21 3.15 62 (16.7) 27.71 25.00 1.51 25.78 22.85 1.75 23.85 20.74 2.02 21.92 21.84 2.34 20.11 20.11 2.72 18.24 18.24 3.15 63 (17.2) 28.20 20.29 1.51 26.21 18.45 1.74 24.21 16.66 2.02 22.17 14.90 2.34 20.07 13.18 2.72 17.90 11.50 3.16 67 (19.4) 30.62 21.18 1.49 28.44 19.28 1.73 26.27 17.42 2.00 24.06 15.60 2.33 21.79 13.82 2.70 19.46 12.09 3.13 72 (22.2) 33.92 17.30 1.46 31.51 15.64 1.70 29.09 14.04 1.98 26.65 12.48 2.31 24.16 10.96 2.68 21.60 9.49 3.11 57 (13.9) 27.64 27.64 1.52 25.91 25.91 1.75 24.16 24.16 2.03 22.37 22.37 2.35 20.52 20.52 2.72 18.59 18.59 3.15 62 (16.7) 28.12 26.02 1.51 26.16 23.78 1.75 24.23 24.10 2.03 22.41 22.41 2.35 20.55 20.55 2.72 18.62 18.62 3.15 63 (17.2) 28.57 20.99 1.51 26.54 19.10 1.75 24.49 17.26 2.02 22.41 15.45 2.35 20.28 13.68 2.72 18.08 11.95 3.16 67 (19.4) 30.99 21.93 1.49 28.78 19.97 1.73 26.56 18.06 2.01 24.30 16.19 2.33 22.00 14.36 2.71 19.64 12.57 3.14 72 (22.2) 34.32 17.77 1.47 31.86 16.08 1.71 29.39 14.44 1.99 26.91 12.85 2.31 24.38 11.29 2.68 21.77 9.79 3.11 57 (13.9) 28.98 28.98 1.52 27.13 27.13 1.76 25.27 25.27 2.03 23.35 23.35 2.35 21.38 21.38 2.73 19.34 19.34 3.16 62 (16.7) 29.01 29.01 1.52 27.17 27.17 1.76 25.30 25.30 2.03 23.39 23.39 2.35 21.41 21.41 2.73 19.37 19.37 3.16 63 (17.2) 29.25 22.53 1.52 27.14 20.52 1.76 25.03 18.57 2.04 22.87 16.64 2.36 20.67 14.76 2.74 18.42 12.92 3.17 67 (19.4) 31.69 23.58 1.50 29.39 21.49 1.74 27.09 19.46 2.02 24.76 17.47 2.34 22.39 15.52 2.72 19.97 13.62 3.15 72 (22.2) 35.05 18.80 1.48 32.49 17.03 1.72 29.94 15.32 2.00 27.37 13.65 2.32 24.76 12.02 2.70 22.08 10.44 3.13 57 (13.9) 30.06 30.06 1.53 28.11 28.11 1.77 26.14 26.14 2.04 24.13 24.13 2.36 22.07 22.07 2.74 19.93 19.93 3.17 62 (16.7) 30.11 30.11 1.53 28.15 28.15 1.77 26.18 26.18 2.04 24.16 24.16 2.36 22.10 22.10 2.74 19.96 19.96 3.17 63 (17.2) 29.77 23.95 1.53 27.60 21.84 1.77 25.42 19.77 2.05 23.22 17.74 2.37 20.98 15.75 2.75 18.70 13.78 3.19 67 (19.4) 32.21 25.10 1.51 29.85 22.90 1.75 27.49 20.76 2.03 25.11 18.66 2.36 22.70 16.60 2.73 20.24 14.57 3.17 72 (22.2) 35.58 19.75 1.49 32.95 17.90 1.73 30.34 16.12 2.01 27.70 14.38 2.34 25.03 12.68 2.71 22.29 11.04 3.14 ee notes on page 14 12

DETAILED COOLING CAPACITIE# (CONTINUED) EVAPORATOR AIR CFM 1200 1300 1355 1500 1600 1700 960 1010 1120 1280 1440 EWB F( C) CONDENER ENTERING AIR TEMPERATURE F ( C) 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7) ys. ys. ys. ys. ys. ys. Total ens Total ens Total ens Total ens Total ens Total ens 24ACB748A*031 Outdoor ection With CNPV*6124A**+58CV(A,X)135---22 Indoor ection --- High 57 (13.9) 47.30 47.30 2.91 44.22 44.22 3.23 41.02 41.02 3.61 37.80 37.80 4.04 34.62 34.62 4.56 31.52 31.52 5.16 62 (16.7) 50.25 41.83 2.93 46.59 39.45 3.25 42.79 37.01 3.62 39.01 34.60 4.05 35.32 32.24 4.56 31.77 29.95 5.17 63 (17.2) 51.23 34.57 2.93 47.48 32.43 3.25 43.59 30.24 3.63 39.71 28.08 4.06 35.92 25.98 4.57 32.25 23.96 5.17 67 (19.4) 55.28 35.82 2.95 51.21 33.62 3.27 47.04 31.41 3.65 42.87 29.21 4.09 38.78 27.06 4.60 34.83 25.00 5.21 72 (22.2) 60.74 29.68 2.97 56.26 27.68 3.30 51.68 25.68 3.68 47.07 23.68 4.12 42.67 21.79 4.65 37.97 19.81 5.24 57 (13.9) 48.75 48.75 2.94 45.52 45.52 3.26 42.20 42.20 3.64 38.85 38.85 4.08 35.56 35.56 4.59 32.33 32.33 5.20 62 (16.7) 51.12 43.71 2.95 47.36 41.24 3.27 43.48 38.72 3.65 39.61 36.23 4.08 35.87 33.78 4.59 32.38 32.38 5.20 63 (17.2) 52.07 35.84 2.96 48.22 33.65 3.28 44.23 31.40 3.65 40.26 29.19 4.09 36.38 27.03 4.60 32.63 24.95 5.20 67 (19.4) 56.14 37.18 2.98 51.97 34.92 3.30 47.69 32.64 3.68 43.42 30.38 4.12 39.25 28.19 4.63 35.21 26.06 5.24 72 (22.2) 61.64 30.52 3.00 57.05 28.49 3.33 52.36 26.44 3.71 47.70 24.43 4.15 43.13 22.47 4.67 38.69 20.58 5.29 57 (13.9) 49.48 49.48 2.96 46.20 46.20 3.28 42.80 42.80 3.66 39.39 39.39 4.09 36.03 36.03 4.61 32.74 32.74 5.22 62 (16.7) 51.56 44.72 2.97 47.74 42.20 3.29 43.82 39.65 3.66 39.92 37.10 4.10 36.17 34.58 4.61 32.79 32.79 5.22 63 (17.2) 52.48 36.53 2.97 48.57 34.30 3.30 44.54 32.02 3.67 40.53 29.78 4.10 36.60 27.60 4.62 32.81 25.49 5.22 67 (19.4) 56.56 37.91 2.99 52.33 35.62 3.32 48.00 33.31 3.69 43.69 31.01 4.13 39.47 28.79 4.65 35.39 26.63 5.26 72 (22.2) 62.08 30.97 3.01 57.42 28.92 3.34 52.68 26.85 3.72 47.97 24.82 4.17 43.35 22.84 4.69 38.88 20.92 5.31 57 (13.9) 51.23 51.23 3.00 47.78 47.78 3.33 44.22 44.22 3.70 40.65 40.65 4.14 37.14 37.14 4.66 33.69 33.69 5.27 62 (16.7) 52.58 47.33 3.01 48.66 44.69 3.33 44.65 42.00 3.70 40.72 40.58 4.14 37.19 37.19 4.66 33.74 33.74 5.27 63 (17.2) 53.41 38.29 3.01 49.38 35.97 3.34 45.25 33.63 3.71 41.12 31.31 4.14 37.11 29.05 4.66 33.23 26.87 5.26 67 (19.4) 57.51 39.78 3.03 53.15 37.41 3.35 48.71 35.02 3.73 44.29 32.66 4.17 39.97 30.35 4.69 35.81 28.12 5.30 72 (22.2) 63.05 32.12 3.05 58.27 30.02 3.38 53.40 27.90 3.76 48.57 25.81 4.21 43.85 23.78 4.73 39.27 21.82 5.35 57 (13.9) 52.31 52.31 3.03 48.75 48.75 3.35 45.10 45.10 3.73 41.42 41.42 4.17 37.81 37.81 4.69 34.28 34.28 5.30 62 (16.7) 53.20 49.06 3.03 49.23 46.33 3.36 45.22 44.88 3.73 41.48 41.48 4.17 37.86 37.86 4.69 34.32 34.32 5.30 63 (17.2) 53.95 39.47 3.04 49.85 37.11 3.36 45.65 34.71 3.73 41.47 32.34 4.17 37.40 30.03 4.68 33.47 27.80 5.29 67 (19.4) 58.05 41.04 3.05 53.63 38.62 3.38 49.12 36.18 3.76 44.64 33.76 4.20 40.26 31.41 4.72 36.04 29.12 5.33 72 (22.2) 63.61 32.89 3.07 58.75 30.75 3.40 53.81 28.60 3.79 48.91 26.48 4.23 44.12 24.41 4.76 39.49 22.42 5.38 57 (13.9) 53.29 53.29 3.06 49.64 49.64 3.38 45.88 45.88 3.76 42.12 42.12 4.20 38.42 38.42 4.72 34.80 34.80 5.33 62 (16.7) 53.79 50.73 3.06 49.81 47.89 3.38 45.95 45.95 3.76 42.18 42.18 4.20 38.47 38.47 4.72 34.84 34.84 5.33 63 (17.2) 54.43 40.62 3.06 50.27 38.21 3.39 46.01 35.77 3.76 41.77 33.35 4.20 37.65 30.99 4.71 33.68 28.70 5.32 67 (19.4) 58.53 42.28 3.08 54.05 39.81 3.41 49.47 37.32 3.78 44.94 34.84 4.22 40.51 32.44 4.74 36.24 30.10 5.35 72 (22.2) 64.10 33.64 3.10 59.16 31.47 3.43 54.15 29.28 3.81 49.20 27.12 4.26 44.36 25.03 4.79 39.67 23.01 5.40 24ACB748A*031 Outdoor ection With CNPV*6124A**+58CV(A,X)135---22 Indoor ection --- Low 57 (13.9) 34.79 34.79 1.95 32.17 32.17 2.27 29.47 29.47 2.63 26.72 26.72 3.04 23.95 23.95 3.52 21.20 21.20 4.07 62 (16.7) 36.22 32.17 1.94 33.19 29.54 2.26 30.08 26.91 2.62 26.94 24.30 3.04 24.00 24.00 3.52 21.24 21.24 4.07 63 (17.2) 36.92 26.30 1.93 33.83 24.03 2.25 30.63 21.75 2.62 27.37 19.49 3.04 24.11 17.30 3.52 20.88 15.17 4.07 67 (19.4) 40.15 27.45 1.91 36.84 25.12 2.23 33.42 22.79 2.59 29.95 20.49 3.01 26.47 18.23 3.49 23.02 16.05 4.04 72 (22.2) 44.69 22.68 1.87 41.06 20.65 2.19 37.33 18.62 2.56 33.54 16.62 2.98 29.75 14.67 3.46 25.97 12.78 4.01 57 (13.9) 35.48 35.48 1.95 32.81 32.81 2.27 30.04 30.04 2.63 27.23 27.23 3.05 24.40 24.40 3.52 21.59 21.59 4.07 62 (16.7) 36.64 33.15 1.94 33.58 30.45 2.26 30.44 27.75 2.63 27.30 27.20 3.04 24.45 24.45 3.52 21.63 21.63 4.07 63 (17.2) 37.32 26.98 1.94 34.18 24.66 2.26 30.94 22.33 2.62 27.63 20.03 3.04 24.33 17.79 3.52 21.07 15.62 4.08 67 (19.4) 40.58 28.18 1.91 37.22 25.80 2.23 33.76 23.42 2.60 30.24 21.06 3.02 26.71 18.76 3.50 23.22 16.53 4.05 72 (22.2) 45.14 23.15 1.87 41.47 21.09 2.20 37.68 19.02 2.57 33.84 16.99 2.99 29.99 15.01 3.47 26.17 13.10 4.02 57 (13.9) 36.87 36.87 1.95 34.08 34.08 2.27 31.19 31.19 2.63 28.25 28.25 3.05 25.31 25.31 3.53 22.38 22.38 4.07 62 (16.7) 37.49 35.25 1.95 34.37 32.41 2.27 31.24 31.24 2.63 28.30 28.30 3.05 25.36 25.36 3.53 22.42 22.42 4.07 63 (17.2) 38.08 28.43 1.94 34.86 26.01 2.26 31.53 23.59 2.63 28.15 21.19 3.05 24.76 18.85 3.53 21.43 16.59 4.09 67 (19.4) 41.40 29.73 1.91 37.95 27.25 2.24 34.39 24.77 2.61 30.78 22.31 3.03 27.17 19.91 3.51 23.60 17.58 4.06 72 (22.2) 46.01 24.15 1.88 42.22 22.02 2.20 38.32 19.89 2.57 34.40 17.78 3.00 30.46 15.73 3.48 26.55 13.75 4.03 57 (13.9) 38.62 38.62 1.96 35.67 35.67 2.28 32.63 32.63 2.64 29.54 29.54 3.06 26.44 26.44 3.53 23.35 23.35 4.08 62 (16.7) 38.70 38.62 1.95 35.73 35.73 2.27 32.68 32.68 2.64 29.59 29.59 3.06 26.48 26.48 3.53 23.39 23.39 4.08 63 (17.2) 38.98 30.46 1.95 35.66 27.91 2.28 32.23 25.35 2.64 28.75 22.82 3.07 25.29 20.35 3.55 21.88 17.94 4.10 67 (19.4) 42.34 31.94 1.93 38.79 29.29 2.25 35.13 26.67 2.62 31.42 24.07 3.04 27.71 21.52 3.52 24.06 19.04 4.07 72 (22.2) 47.00 25.53 1.89 43.09 23.30 2.22 39.09 21.07 2.59 35.04 18.88 3.01 30.99 16.73 3.49 26.97 14.66 4.04 57 (13.9) 40.11 40.11 1.96 37.03 37.03 2.28 33.85 33.85 2.65 30.63 30.63 3.07 27.39 27.39 3.54 24.17 24.17 4.09 62 (16.7) 40.18 40.18 1.96 37.09 37.09 2.28 33.91 33.91 2.65 30.68 30.68 3.07 27.43 27.43 3.54 24.20 24.20 4.09 63 (17.2) 39.70 32.42 1.97 36.29 29.74 2.29 32.80 27.05 2.66 29.25 24.39 3.08 25.73 21.77 3.56 22.32 22.12 4.12 67 (19.4) 43.09 34.04 1.94 39.46 31.27 2.26 35.72 28.51 2.63 31.92 25.76 3.06 28.16 23.08 3.54 24.46 20.44 4.09 72 (22.2) 47.76 26.84 1.90 43.76 24.52 2.23 39.67 22.21 2.60 35.52 19.93 3.03 31.38 17.70 3.51 27.28 15.54 4.06 ee notes on page 14 13

DETAILED COOLING CAPACITIE# (CONTINUED) EVAPORATOR AIR CFM 1500 1625 1750 2000 1100 1225 1350 1475 EWB F( C) CONDENER ENTERING AIR TEMPERATURE F ( C) 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7) ys. ys. ys. ys. ys. ys. Total ens Total ens Total ens Total ens Total ens Total ens 24ACB760AB032 Outdoor ection With CAP**6124AL* Indoor ection --- High 57 (13.9) 52.86 52.86 3.81 51.03 51.03 4.17 49.08 49.08 4.58 46.93 46.93 5.05 44.52 44.52 5.60 41.77 41.77 6.21 62 (16.7) 55.69 48.76 3.84 53.31 47.64 4.19 50.79 46.46 4.60 48.06 45.18 5.07 45.06 43.75 5.60 41.74 41.74 6.21 63 (17.2) 56.79 39.92 3.85 54.36 38.80 4.20 51.76 37.63 4.61 48.94 36.37 5.07 45.81 34.99 5.61 42.35 33.48 6.22 67 (19.4) 61.31 41.44 3.90 58.67 40.31 4.25 55.83 39.13 4.65 52.75 37.85 5.12 49.38 36.47 5.66 45.62 34.95 6.26 72 (22.2) 67.55 33.95 3.96 64.42 32.75 4.30 61.47 31.63 4.72 58.04 30.35 5.18 54.28 28.96 5.72 50.16 27.42 6.33 57 (13.9) 54.39 54.39 3.88 52.47 52.47 4.23 50.41 50.41 4.64 48.15 48.15 5.12 45.60 45.60 5.66 42.74 42.74 6.27 62 (16.7) 56.55 50.96 3.90 54.10 49.81 4.25 51.51 48.60 4.66 48.72 47.26 5.12 45.72 45.62 5.66 42.80 42.80 6.27 63 (17.2) 57.59 41.39 3.91 55.07 40.26 4.26 52.40 39.08 4.66 49.48 37.79 5.13 46.28 36.40 5.67 42.72 34.86 6.27 67 (19.4) 62.15 43.03 3.95 59.42 41.89 4.30 56.50 40.68 4.71 53.33 39.39 5.18 49.84 37.98 5.71 45.99 36.44 6.32 72 (22.2) 68.43 34.93 4.02 65.39 33.78 4.37 62.16 32.57 4.77 58.63 31.26 5.24 54.80 29.86 5.78 50.53 28.32 6.38 57 (13.9) 55.76 55.76 3.94 53.76 53.76 4.29 51.60 51.60 4.71 49.24 49.24 5.18 46.59 46.59 5.72 43.60 43.60 6.34 62 (16.7) 57.31 53.09 3.95 54.80 51.91 4.31 52.18 50.65 4.71 49.87 48.12 5.19 46.66 46.66 5.72 43.67 43.67 6.34 63 (17.2) 58.26 42.83 3.96 55.68 41.69 4.31 52.92 40.47 4.72 49.93 39.18 5.19 46.67 37.77 5.72 43.03 36.21 6.33 67 (19.4) 62.85 44.57 4.01 60.03 43.41 4.36 57.05 42.19 4.76 53.79 40.87 5.23 50.24 39.46 5.77 46.31 37.90 6.37 72 (22.2) 69.20 35.92 4.08 65.95 34.66 4.42 62.68 33.47 4.83 59.12 32.16 5.29 55.14 30.71 5.83 50.83 29.18 6.44 57 (13.9) 58.07 58.07 4.06 55.90 55.90 4.42 53.58 53.58 4.83 51.01 51.01 5.30 48.19 48.19 5.84 44.96 44.96 6.45 62 (16.7) 58.62 57.09 4.07 56.08 55.76 4.42 53.66 53.66 4.83 51.09 51.09 5.30 48.25 48.25 5.84 45.03 45.03 6.46 63 (17.2) 59.34 45.61 4.07 56.62 44.43 4.42 53.75 43.19 4.83 50.63 41.85 5.29 47.24 40.41 5.83 43.48 38.79 6.43 67 (19.4) 63.96 47.56 4.12 61.03 46.38 4.47 57.88 45.12 4.87 54.51 43.77 5.34 50.80 42.30 5.87 46.76 40.71 6.48 72 (22.2) 70.34 37.66 4.19 67.07 36.47 4.53 63.58 35.22 4.93 59.85 33.88 5.40 55.75 32.43 5.94 51.28 30.87 6.55 24ACB760AB032 Outdoor ection With CAP**6124AL* Indoor ection --- Low 57 (13.9) 39.47 39.47 2.61 36.39 36.39 2.93 33.18 33.17 3.30 29.90 29.90 3.71 26.63 26.63 4.17 23.40 23.40 4.69 62 (16.7) 41.54 36.96 2.59 37.89 34.50 2.92 34.11 31.99 3.29 30.29 29.44 3.71 26.70 26.70 4.17 23.44 23.44 4.69 63 (17.2) 42.47 30.19 2.59 38.74 28.02 2.92 34.87 25.80 3.29 30.92 23.57 3.71 27.01 21.39 4.17 23.18 19.23 4.69 67 (19.4) 46.16 31.48 2.56 42.12 29.27 2.89 37.96 27.00 3.27 33.75 24.71 3.68 29.56 22.50 4.15 25.47 20.32 4.67 72 (22.2) 51.16 25.80 2.52 46.73 23.82 2.86 42.18 21.81 3.24 37.59 19.81 3.66 33.03 17.84 4.13 28.56 15.92 4.65 57 (13.9) 41.11 41.11 2.64 37.86 37.86 2.97 34.48 34.48 3.34 31.05 31.05 3.75 27.62 27.62 4.21 24.23 24.23 4.73 62 (16.7) 42.45 39.32 2.63 38.70 36.74 2.96 34.84 34.07 3.33 31.11 31.11 3.75 27.67 27.67 4.21 24.27 24.27 4.73 63 (17.2) 43.35 31.80 2.63 39.49 29.54 2.96 35.50 27.24 3.33 31.45 24.93 3.75 27.43 22.64 4.22 23.51 20.42 4.74 67 (19.4) 47.06 33.20 2.60 42.89 30.88 2.93 38.60 28.53 3.31 34.28 26.17 3.73 29.98 23.86 4.19 25.80 21.61 4.72 72 (22.2) 52.13 26.86 2.56 47.56 24.83 2.90 42.87 22.76 3.28 38.15 20.70 3.70 33.47 18.67 4.17 28.89 16.70 4.69 57 (13.9) 42.54 42.54 2.67 39.15 39.15 3.00 35.63 35.63 3.37 32.05 32.05 3.79 28.47 28.47 4.25 24.94 24.94 4.77 62 (16.7) 43.25 41.59 2.67 39.54 38.98 3.00 35.69 35.69 3.37 32.10 32.10 3.79 28.52 28.52 4.25 24.98 24.98 4.77 63 (17.2) 44.04 33.35 2.67 41.92 41.92 2.98 36.00 28.63 3.37 31.86 26.24 3.79 27.77 23.88 4.26 23.78 21.57 4.78 67 (19.4) 47.76 34.85 2.64 43.49 32.46 2.97 39.11 30.03 3.35 34.69 27.60 3.77 30.32 25.20 4.24 26.05 22.85 4.76 72 (22.2) 52.88 27.89 2.60 48.19 25.79 2.94 43.39 23.67 3.32 38.57 21.56 3.74 33.80 19.49 4.21 29.12 17.46 4.73 57 (13.9) 43.82 43.82 2.71 40.29 40.29 3.04 36.62 36.62 3.41 32.91 32.91 3.83 29.16 29.16 4.29 25.55 25.55 4.81 62 (16.7) 44.56 42.51 2.70 40.36 40.36 3.04 36.68 36.68 3.41 32.96 32.96 3.82 29.24 29.24 4.29 25.59 25.59 4.81 63 (17.2) 44.62 34.87 2.71 40.58 32.45 3.04 36.41 29.99 3.41 32.20 27.53 3.83 28.04 25.08 4.30 24.01 22.68 4.83 67 (19.4) 48.34 36.48 2.68 43.99 34.01 3.01 39.45 31.46 3.39 35.02 28.98 3.81 30.58 26.50 4.28 26.27 24.06 4.80 72 (22.2) 53.48 28.88 2.64 48.68 26.73 2.98 43.67 24.54 3.35 38.90 22.39 3.78 34.04 20.27 4.25 29.30 18.21 4.78 { Total and sensible capacities are net capacities. Blower motor heat has been subtracted. } ensible capacities shown are based on 80_F (27_C) entering air at the indoor coil. For sensible capacities at other than 80_F (27_C), deduct 835 Btuh (245 kw) per 1000 CFM (480 L/) of indoor coil air for each degree below 80_F (27_C), or add 835 Btuh (245 kw) per 1000 CFM (480 L/) of indoor coil air per degree above 80_F (27_C). # Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per AHRI standard 210/240---2008. If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur. ** ystem kw is total of indoor and outdoor unit kilowatts. At TVA rating indoor condition (75_F edb/63_f ewb). All other indoor air temperatures are at 80_F edb. EWB Entering Wet Bulb NOTE: When the required data fall between the published data, interpolation may be performed. Extrapolation is not an acceptable practice. 14

CONDENER ONLY RATING* T CONDENER ENTERING AIR TEMPERATURE F ( C) F( C) 55 (12.78) 65 (18.33) 75 (23.89) 85 (29.44) 95 (35.0) 105 (40.56) 115 (46.11) 125 (51.67) 24ACB724A**31 TCG 28.00 25.00 21.90 18.90 16.00 13.30 10.70 8.50 30 (---1.11) DT 71.60 81.50 91.40 101.20 111.00 120.80 130.80 140.90 KW 1.20 1.30 1.40 1.51 1.63 1.76 1.92 2.11 TCG 31.20 27.70 24.30 21.00 17.80 14.80 12.10 9.60 35 (1.67) DT 73.20 83.00 92.80 102.60 112.40 122.20 132.10 142.10 KW 1.23 1.33 1.43 1.53 1.65 1.79 1.95 2.14 TCG 34.60 30.70 26.90 23.20 19.80 16.50 13.50 10.70 40 (4.44) DT 74.80 84.60 94.40 104.10 113.90 123.50 133.40 143.30 KW 1.25 1.35 1.45 1.56 1.68 1.82 1.98 2.17 TCG 38.20 33.90 29.70 25.70 21.90 18.30 15.00 12.00 45 (7.22) DT 76.60 86.30 96.00 105.70 115.20 124.90 134.70 144.60 KW 1.28 1.38 1.48 1.58 1.70 1.84 2.01 2.20 TCG 42.00 37.30 32.60 28.30 24.10 20.20 16.60 13.40 50 (10.0) DT 78.40 88.00 97.60 107.10 116.70 126.30 136.00 145.90 KW 1.31 1.40 1.50 1.60 1.72 1.87 2.03 2.23 TCG 46.10 40.90 35.80 31.00 26.50 22.30 18.40 14.80 55 (12.78) DT 80.20 89.70 99.20 108.60 118.10 127.70 137.40 147.10 KW 1.34 1.43 1.52 1.63 1.75 1.89 2.06 2.26 TCG 50.50 44.70 39.20 33.90 29.00 24.40 20.20 16.30 60 (15.56) DT 82.00 91.40 100.80 110.20 119.70 129.20 138.80 148.40 KW 1.37 1.45 1.54 1.65 1.77 1.92 2.09 2.28 24ACB724A**31 TCG 13.50 13.60 13.30 12.80 12.20 11.30 10.40 9.40 30 (---1.11) DT 66.80 76.80 86.70 96.50 106.30 116.00 125.70 135.70 KW 0.77 0.89 1.03 1.18 1.35 1.53 1.74 1.96 TCG 15.20 15.20 14.90 14.40 13.70 12.90 11.90 10.90 35 (1.67) DT 68.00 78.00 87.90 97.70 107.40 117.10 126.90 136.90 KW 0.77 0.89 1.02 1.17 1.34 1.53 1.74 1.98 TCG 16.90 16.90 16.60 16.00 15.30 14.50 13.50 12.50 40 (4.44) DT 69.30 79.30 89.00 98.80 108.50 118.20 128.10 138.10 KW 0.76 0.88 1.01 1.17 1.34 1.53 1.75 1.99 TCG 18.80 18.70 18.30 17.80 17.00 16.20 15.20 14.10 45 (7.22) DT 70.60 80.50 90.30 100.00 109.70 119.40 129.20 139.20 KW 0.75 0.87 1.00 1.16 1.33 1.53 1.76 2.01 TCG 20.80 20.60 20.20 19.60 18.90 18.00 17.00 15.90 50 (10.0) DT 72.00 81.80 91.50 101.20 110.80 120.50 130.40 140.30 KW 0.74 0.86 0.99 1.15 1.33 1.53 1.76 2.02 TCG 22.90 22.70 22.20 21.60 20.80 19.90 18.80 17.80 55 (12.78) DT 73.40 83.20 92.80 102.40 112.10 121.70 131.50 141.40 KW 0.73 0.84 0.98 1.14 1.32 1.53 1.77 2.03 TCG 25.10 24.80 24.30 23.70 22.80 21.90 20.80 19.70 60 (15.56) DT 74.90 84.60 94.10 103.70 113.30 122.90 132.60 142.40 KW 0.72 0.83 0.97 1.13 1.32 1.53 1.77 2.04 24ACB736A**31 --- High TCG 34.80 32.30 29.80 27.40 25.00 22.60 20.10 17.60 30 (---1.11) DT 71.10 80.60 90.10 99.60 109.10 118.50 127.80 137.20 KW 1.72 1.87 2.04 2.25 2.47 2.72 3.00 3.29 TCG 38.50 35.70 33.10 30.40 27.80 25.10 22.40 19.60 35 (1.67) DT 72.60 82.00 91.50 100.90 110.30 119.70 128.90 138.20 KW 1.76 1.91 2.08 2.28 2.50 2.76 3.03 3.33 TCG 42.40 39.40 36.50 33.60 30.70 27.80 24.80 21.80 40 (4.44) DT 74.20 83.60 93.00 102.40 111.70 120.90 130.10 139.20 KW 1.81 1.95 2.11 2.31 2.53 2.79 3.06 3.37 TCG 46.50 43.30 40.20 37.00 33.90 30.70 27.50 24.20 45 (7.22) DT 75.90 85.20 94.50 103.80 113.00 122.20 131.30 140.30 KW 1.87 1.99 2.15 2.34 2.57 2.82 3.10 3.40 TCG 50.90 47.50 44.00 40.60 37.20 33.80 30.30 26.70 50 (10.0) DT 77.60 86.80 96.10 105.30 114.40 123.50 132.50 141.40 KW 1.92 2.04 2.19 2.38 2.60 2.85 3.13 3.44 TCG 55.50 51.80 48.10 44.50 40.80 37.00 33.20 29.40 55 (12.78) DT 79.40 88.50 97.70 106.80 115.90 124.90 133.80 142.60 KW 1.99 2.09 2.24 2.42 2.64 2.89 3.17 3.47 TCG 60.40 56.40 52.50 48.50 44.50 40.40 36.40 32.30 60 (15.56) DT 81.20 90.20 99.30 108.40 117.40 126.30 135.00 143.80 KW 2.05 2.15 2.29 2.47 2.68 2.93 3.20 3.51 ee notes on page 19 15

CONDENER ONLY RATING* CONTINUED T CONDENER ENTERING AIR TEMPERATURE F ( C) F( C) 55 (12.78) 65 (18.33) 75 (23.89) 85 (29.44) 95 (35.0) 105 (40.56) 115 (46.11) 125 (51.67) 24ACB736A**31 --- Low TCG 20.70 20.10 19.50 18.80 18.00 16.90 15.60 14.10 30 (---1.11) DT 65.70 75.40 85.10 94.80 104.50 114.10 123.60 133.10 KW 1.18 1.31 1.47 1.66 1.88 2.13 2.43 2.78 TCG 23.10 22.40 21.80 21.00 20.10 19.00 17.60 16.00 35 (1.67) DT 66.80 76.50 86.10 95.80 105.40 115.00 124.50 134.00 KW 1.16 1.30 1.46 1.65 1.87 2.12 2.42 2.76 TCG 25.60 25.00 24.20 23.40 22.40 21.20 19.80 18.10 40 (4.44) DT 68.00 77.60 87.30 96.90 106.50 116.00 125.40 134.90 KW 1.13 1.28 1.45 1.64 1.86 2.11 2.41 2.75 TCG 28.40 27.70 26.90 26.00 24.90 23.70 22.10 20.30 45 (7.22) DT 69.30 78.80 88.40 98.00 107.50 117.00 126.40 135.80 KW 1.11 1.26 1.43 1.63 1.85 2.10 2.40 2.73 TCG 31.40 30.60 29.70 28.70 27.60 26.20 24.60 22.70 50 (10.0) DT 70.60 80.10 89.60 99.20 108.60 118.00 127.40 136.70 KW 1.08 1.24 1.42 1.61 1.84 2.09 2.39 2.72 TCG 34.60 33.70 32.70 31.70 30.40 29.00 27.30 25.30 55 (12.78) DT 72.00 81.50 90.90 100.40 109.80 119.10 128.40 137.60 KW 1.06 1.22 1.40 1.60 1.83 2.08 2.38 2.71 TCG 38.10 37.00 36.00 34.80 33.50 31.90 30.10 28.00 60 (15.56) DT 73.50 82.90 92.30 101.60 111.00 120.20 129.40 138.60 KW 1.03 1.20 1.38 1.59 1.82 2.07 2.36 2.69 24ACB748A**31 --- High TCG 44.30 42.30 39.70 36.70 33.50 30.30 27.10 24.20 30 (---1.11) DT 69.60 79.40 88.90 98.30 107.70 117.10 126.50 136.00 KW 2.00 2.27 2.56 2.88 3.24 3.67 4.16 4.76 TCG 49.40 47.10 44.10 40.80 37.30 33.80 30.40 27.20 35 (1.67) DT 71.20 80.80 90.30 99.60 108.90 118.20 127.60 137.00 KW 2.04 2.31 2.60 2.91 3.28 3.70 4.21 4.80 TCG 54.80 52.00 48.70 45.10 41.30 37.50 33.90 30.40 40 (4.44) DT 72.80 82.30 91.60 100.90 110.20 119.40 128.70 138.00 KW 2.08 2.35 2.63 2.95 3.32 3.75 4.25 4.86 TCG 60.40 57.20 53.50 49.60 45.50 41.40 37.50 33.80 45 (7.22) DT 74.40 83.80 93.00 102.20 111.40 120.60 129.80 139.10 KW 2.12 2.38 2.67 2.99 3.36 3.79 4.31 4.91 TCG 66.10 62.60 58.60 54.30 49.90 45.50 41.40 37.40 50 (10.0) DT 76.00 85.30 94.50 103.60 112.70 121.80 131.00 140.20 KW 2.15 2.41 2.70 3.02 3.40 3.84 4.36 4.98 TCG 72.10 68.10 63.80 59.10 54.40 49.80 45.30 41.10 55 (12.78) DT 77.60 86.80 95.90 105.00 114.00 123.10 132.10 141.30 KW 2.18 2.44 2.73 3.06 3.44 3.89 4.42 5.04 TCG 78.20 73.80 69.10 64.10 59.10 54.20 49.50 44.90 60 (15.56) DT 79.30 88.40 97.40 106.40 115.40 124.30 133.30 142.30 KW 2.20 2.46 2.76 3.09 3.48 3.94 4.48 5.11 24ACB748A**31 --- Low TCG 27.10 26.70 25.90 24.60 23.00 21.00 18.70 16.20 30 (---1.11) DT 65.00 74.70 84.40 93.90 103.40 112.80 122.20 131.50 KW 1.44 1.66 1.90 2.18 2.49 2.84 3.25 3.71 TCG 30.20 29.70 28.80 27.50 25.90 23.80 21.50 18.80 35 (1.67) DT 66.00 75.70 85.30 94.80 104.30 113.70 123.10 132.40 KW 1.41 1.64 1.88 2.16 2.47 2.83 3.23 3.69 TCG 33.50 33.00 32.10 30.70 29.00 26.90 24.40 21.70 40 (4.44) DT 67.10 76.80 86.30 95.80 105.30 114.60 124.00 133.30 KW 1.38 1.61 1.86 2.14 2.45 2.81 3.22 3.68 TCG 37.00 36.50 35.60 34.20 32.40 30.20 27.70 24.80 45 (7.22) DT 68.30 77.90 87.40 96.90 106.30 115.60 124.90 134.10 KW 1.35 1.58 1.84 2.12 2.44 2.79 3.20 3.66 TCG 40.90 40.30 39.40 37.90 36.10 33.80 31.20 28.20 50 (10.0) DT 69.50 79.10 88.60 98.00 107.40 116.60 125.80 135.00 KW 1.32 1.56 1.81 2.10 2.42 2.78 3.18 3.64 TCG 45.00 44.50 43.50 42.00 40.10 37.80 35.00 31.90 55 (12.78) DT 70.90 80.40 89.80 99.20 108.50 117.70 126.90 136.00 KW 1.29 1.53 1.79 2.08 2.40 2.76 3.16 3.62 TCG 49.60 49.00 47.90 46.40 44.40 42.00 39.20 35.90 60 (15.56) DT 72.30 81.80 91.10 100.40 109.70 118.80 127.90 137.00 KW 1.26 1.50 1.77 2.06 2.38 2.74 3.15 3.60 ee notes on page 19 16