VWR Laboratory Refrigerators and Freezers

VWR LABORATORY REFRIGERATORS AND FREEZERS. Versatile Storage Options Designed for Your Needs

Versatile new products for multiple applications and specialty conditions. New Products Catalog

Pharmacy. Refrigerators and Freezers MEET STATE AND FEDERAL GUIDELINES

SILVER. Versatile new products for multiple applications and specialty conditions. Futura Silver Series Product Catalog

Laboratory & Pharmacy Refrigerators

Upright Chromatography Refrigerators

Vaccine & Pharmacy Upright Glass Door Refrigerators

Freezers. Upright Laboratory & Plasma. i.series Horizon Series

Freezers. Laboratory & Plasma. i.series Horizon Series

Freezers. Laboratory & Plasma. i.series Horizon Series. Distinctly. Innovation can be beautiful.

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

Refrigerators. Upright Blood Bank. i.series Horizon Series

Thermo Scientific Revco Value Freezers and Refrigerators. General Purpose Explosion Proof Flammable Material Chromatography

Upright Freezers. Laboratory Plasma. TrueBlue. Reliability & Support. i.series Horizon Series

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

Biomedical Freezer 37 38

Upright Refrigerators. Blood Bank. TrueBlue. Reliability & Support. i.series Horizon Series

FREE ZERS LABORATORY FREEZERS -30 O C. i.series TM Horizon Series TM

Undercounter Refrigerators and Freezers. Laboratory/Pharmacy Blood Bank. TrueBlue. Reliability & Support. i.series Horizon Series Scientific Series

DOUBLE DOOR FREEZER.

ULTRA.GUARD ultra low temperature freezer

86 C freezers. New Benchmark. New Brunswick sets the standard for extraordinary freezer quality, support, and energy savings

Thermo Scientific Revco UxF -80C Series Upright ULT Freezers

Protect your research

NEW! Thermo Scientific Revco PLUS Ultra-Low Temperature Upright Freezers. Maximizing Critical Sample Protection and Storage

Cardinal Health Ultra-Low Freezers. Protecting your samples requiring ultra-low storage

Pass-Thru Refrigerators. Pharmacy & Blood Bank. TrueBlue. Reliability & Support. i.series Horizon Series

Laboratory Pharmacy Blood Bank. Upright Refrigerators and Freezers

Cardinal Health Refrigerators and Freezers. Keeping your samples safe

Platelet Storage. i.series Horizon Series

Thermo Scientific Revco Laboratory Refrigerators and Freezers

NEW! Thermo Scientific Revco PLUS -86 C Freezers. Protecting Your Life s Work

BIOMEDICAL FREEZERS ULTRA LOW TEMPERATURE FREEZERS LOW TEMPERATURE FREEZERS

REFRIGERATOR M E D I C A L.

Keeping your samples safe

Thermo Scientific Flammable Material and Explosion-Proof Refrigerators and Freezers. Safe cold storage for Hazardous material

NEW! TSX Series high-performance undercounter refrigerators

Platelet Storage. i.series Horizon Series

StableClimate Stability Chambers

NEW! TSX Series high-performance undercounter refrigerators

NEW! Thermo Scientific Revco PLUS Ultra-Low Temperature Upright Freezers. Maximizing Critical Sample Protection and Storage

Stability Chambers & Rooms

Pharmacy Refrigerator

Thermo Fisher Scientific ULT Clinic. Peter Diebold Cold Storage Specialist

Reliable cooling solutions...

Ultra-Low. Temperature. Freezers. Advantage Series. Basic Series. Microprocessor Control. Solid-State Electronic Control

TSX Series High-Performance Refrigerators and Freezers

& Freezers. Selection Guide. Laboratory Refrigerators & Freezers. Accessories & Options

Undercounter Units. 20 Call or Text for pricing on True and other great brands! UNDERCOUNTERS & WORKTOPS (19 24) REFRIGERATION

Multi-Lab REFRIGERATORS Frigidere medicale

Undercounter Refrigerator Operation Manual

-86 C ULTRALOW TEMPERATURE FREEZERS. NuAire, Inc Fernbrook Lane Plymouth, MN U.S.A

Undercounter Refrigerator Operation Manual i.series and Horizon Series

Digital incubating/ refrigerating benchtop shakers

Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter

TSX Series High-Performance Refrigerators and Freezers

MEDICAL DEVICES. Refrigerators HELMER HIGH QUALITY REFRIGERATORS

TEMPERATURE FREEZERS -90

NEW Cold Storage Offers that deliver the right cold storage solutions at the right time. That s smart

Refrigerators & ULT Freezers

-86 C Ultra-Low Freezers. How It s Made. Matters

Igloo. Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter

FITOCLIMA 600 & 1200 STABILITY

BUSINESS SOLUTIONS. Biomedical REFRIGERATORS & FREEZERS FOR BIOMEDICAL NEEDS

Environmental Chambers. 2-Door & 3-Door Extra Large Capacity

TwinGuard ULTRA LOW TEMPERATURE FREEZERS SERIES

our obsession your samples Thermo Scientific Revco High-Performance Laboratory Refrigerators and Freezers

TSX Series High-Performance Refrigerators and Freezers

Fri.med. Srl Via Riva, 26/ Buttigliera d Asti (AT) Italy Tel Fax

Advance Blood Storage system from Meditech

TSX Series High-Performance Refrigerators and Freezers

Thermo Scientific HERAfreeze Top and Basic Freezers Solutions for safe sample storage

Ultra low temperature freezers -40 C and -86 C. NEXUS Series

ICS PACIFIC G135L MEDICAL

TwinGuard ULTRA LOW TEMPERATURE FREEZERS

MEDICAL REFRIGERATORS

TSX Series High-Performance Refrigerators and Freezers

REFRIGERATOR P H A R M A C Y.

PR-L2466W- PA. Operating Instructions. High Performance Refrigerator PR-L2466W-PA

Ultra low temperature freezers -40 C and -86 C. NEXUS Series

Laboratory refrigerators and freezers

New. ENERGY STAR Certified VIP ECO Earns Industry s Lowest Energy Consumption Rating for Ultra-Low Temperature Freezers 1

Constant climate chambers

FITOCLIMA 600 & 1200 STABILITY

FITOCLIMA 600 & 1200 PHARMA

Protection, safety, reliability. And more.

PPR-S GD. 145 Litre Pharmacy Refrigerator (Under Bench) QCPP Approved

-86 C ULTRA-LOW TEMPERATURE FREEZERS SERIES

Environmental Chambers Series: reach-in & benchtop capacities

Thermo Scientific HERAfreeze Top and Basic Freezers Solutions for safe sample storage

-86 Ultra Low Temperature Freezer

Product Catalog. summitmedicalrefrigerators.com l Medical & Pharmacy Refrigeration. Scientific & Laboratory Refrigeration

Twin Guard Series -86 C Ultra-Low Freezer Featuring SANYO -86 Dual Cool Independent Refrigeration Systems MDF-U500VXC

Full Adjustable Shelves

GENERAL PURPOSE LABORATORY GRADE REFRIGERATORS AND FREEZERS. Versatile 4 C and -20 C preservation for laboratory research and life science materials.

Ultra-Low Temperature Freezer powered by Smart-Lab TM System

ULTRA LOW TEMPERATURE FREEZER. User Manual

Platelet bags constant shaking for long periods of time.

Blanket and Solution Warming Cabinets

Transcription:

REFRIGERATORS AND FREEZERS laboratory chromatography ultra low temp pharmacy vaccine hazardous flammable undercounter performance qualified

ULTRA LOW TEMP The LRP Ultra-Low Temperature Freezer delivers rich features and benefits for the most demanding cold storage applications. Designed to utilize standard racks, this unit offers energy efficient operation with low noise by utilizing two high efficiency compressors that keep decibel levels low; while still having a 300 BTU/h reserve capacity. The interior of the unit features a triple gasket seal, vacuum relief port, five double walled insulated doors, and 5 ½ -6 of Urethane insulation in critical areas. 115V and 230V models available in 17 and 21 cu. ft. sizes, 230V only in 25 cu. ft. Features & Benefits: Added Sample Security 21 audible & visual alarms Voltage booster to protect the compressor during periods of low voltage Battery backup for alarms Rear access port for central building alarm system Reserve Capacity with High Efficiency & Low Noise Two high efficiency compressors 300 BTU/h reserve capacity Low decibel levels User Friendly Maintenance Easy to access and clean condenser filter Low profile casters with locks Control Center Large LCD control panel Oversized LED temperature display Password protected Ergonomic Door Handle Easy one-hand open & close Key lockable for sample security Diagnostic Capabilities RS-232 accommodates downloading of event logs External Monitoring 4-20mA output Remote alarm contacts Compatible with external alarms and monitoring systems Two year parts and labor warranty, plus an additional three years on compressor parts Chart Recorder LRP-115V-1786 Model Cu. Ft. Temp 2 Box Capacity # of Racks EXT/INT Doors Shelves Width (in.) Depth (in.) Height (in.) Shipping Weight Ultra Low Temperature LRP-115V-1786 17-50 C to -86 C 320 20 1 Solid/5 insulated 4 38 37 80 700 LRP-230V-1786 17-50 C to -86 C 320 20 1 Solid/5 insulated 4 38 37 80 700 LRP-115V-2186 21-50 C to -86 C 400 25 1 Solid/5 insulated 4 43 37 80 759 LRP-230V-2186 21-50 C to -86 C 400 25 1 Solid/5 insulated 4 43 37 80 759 LRP-230V-2586 25-50 C to -86 C 480 30 1 Solid/5 insulated 4 49 37 80 829 2

VALI-DATE SERIES plus The Vali-Date Plus Series units are performance qualified to help satisfy qualification and validation requirements. These units feature a microprocessor temperature controller and display which allows for precise temperature control, verification and recovery versus mechanical style thermostats. An interior fan driven, forced-draft air circulation system provides excellent temperature uniformity and recovery after door openings. Critical samples and supplies are security backed with an extensive package of audible and visual alarms. Auto defrost freezer models have programmed defrost cycles that will reach air temperatures of approximately 0 C. In addition, enhanced operation manuals are included to make the commissioning as well as the Installation Qualifications virtually effortless. These manuals feature multi-point temperature mapping via LRP s NIST traceable data acquisition equpiment assuring reproducible operation. if provided with a Requirements Document, LRP will make every effort to fulfill or exceed each condition. Microprocessor Temperature Controller: - Digital Display - Audible and Visual High & Low Temperature Alarms - Door Ajar Alarm - Battery Back-up for audible and visual alarms - Power Failure Alarm - Sensor Error Alarm - Remote Alarm Contacts - High & Low Non-volatile Temperature Memory with reset - Audible Alarm Mute Button Enhanced Operation Manual - Multi-point Temperature Mapping via LRP s NIST traceable data acquisition Swivel Casters (Adds 4 to unit height) Interior Light Stainless Steel Interior / Exterior Three year parts and labor warranty, plus an additional two years on compressor parts Chart Recorders Additional Shelves PQ-AF49 PQ-R49G PQ-R72S Vali-Date Plus Series Refrigerators PQ-R23S 23 0 C to 10 C Cycle Single Swing Solid Door 3 27 30 79 1/3 330 PQ-R23G 23 0 C to 10 C Cycle Single Swing Glass Door 3 27 31 79 1/3 355 PQ-R49S 49 0 C to 10 C Cycle Double Swing Solid Door 6 54 30 79 1/2 485 PQ-R49G 49 0 C to 10 C Cycle Double Swing Glass Door 6 54 31 79 1/2 515 PQ-R72S 72 0 C to 10 C Cycle Triple Swing Solid Door 9 78 30 79 1/2 670 PQ-R72G 72 0 C to 10 C Cycle Triple Swing Glass Door 9 78 31 79 1/2 715 Vali-Date Plus Series Freezers PQ-AF23 23-18 C to -25 C* Auto Single Swing Solid Door 3 27 30 79 1/3 330 PQ-AF49 49-18 C to -25 C* Auto Double Swing Solid Door 6 54 30 79 3/4 525 *Note: Auto defrost freezer models have programmed defrost cycles that will reach air temperatures of approximately 0 C 3

LABORATORY/PHARMACY plus The Laboratory Plus Series Refrigerators feature a microprocessor temperature controller and display, allowing for precise temperature control, verification and recovery versus mechanical style thermostats. An interior fan driven, forced-draft air circulation system provides excellent temperature uniformity and recovery after door openings. Critical samples and supplies are security backed with an extensive package of audible and visual alarms. Microprocessor Temperature Controller: Digital Display - Audible and Visual High & Low Temperature Alarms - Door Ajar Alarm - Battery Back-up for audible and visual alarms - Power Failure Alarm - Sensor Error Alarm - Remote Alarm Contacts - High & Low Non-volatile Temperature Memory with reset - Audible Alarm Mute Button Swivel Casters (Adds 4 to unit height) Interior Light - Excludes ARU-3004-GP Three year parts and labor warranty, plus an additional two years on compressor parts LRP-49 Door Locks Chart Recorders Solid Door Conversion Additional Shelves ARU-3004-GP LRP-72 4 Laboratory Plus Series LRP-10 10 0 C to 10 C Cycle Single Swing Glass Door 3 25 24 53 1/5 220 LRP-12 12 0 C to 10 C Cycle Single Swing Glass Door 3 25 24 62 1/5 240 LRP-19 19 0 C to 10 C Cycle Single Swing Glass Door 4 27 25 79 1/3 295 LRP-23 23 0 C to 10 C Cycle Single Swing Glass Door 4 27 30 79 1/3 375 LRP-26 26 0 C to 10 C Cycle Single Swing Glass Door 4 30 30 79 1/3 355 ARU-3004-GP 30 0 C to 10 C Cycle Single Swing Glass Door 5 36 34 79 1/3 515 LRP-33 33 0 C to 10 C Cycle Double Slide Glass Door 8 40 30 79 1/3 425 LRP-35 35 0 C to 10 C Cycle Double Swing Glass Door 8 40 31 79 1/3 425 LRP-37 37 0 C to 10 C Cycle Double Slide Glass Door 8 44 30 79 1/3 440 LRP-41 41 0 C to 10 C Cycle Double Slide Glass Door 8 47 30 79 1/3 450 LRP-45 45 0 C to 10 C Cycle Double Slide Glass Door 8 51 30 79 1/2 480 LRP-47 47 0 C to 10 C Cycle Double Slide Glass Door 8 54 30 79 1/2 505 LRP-49 49 0 C to 10 C Cycle Double Swing Glass Door 8 54 31 79 1/2 510 LRP-69 69 0 C to 10 C Cycle Triple Slide Glass Door 12 78 30 80 3/4 695 LRP-72 72 0 C to 10 C Cycle Triple Swing Glass Door 12 78 31 80 3/4 690

basic The Laboratory Basic Series Refrigerators offer a robust and reliable refrigeration system controlled by a mechanical (dial) thermostat. The Basic Series provides an economical choice for general purpose applications where the precision of a microprocessor temperature controller and security alarms are not required. These units are not intended for high-value laboratory supplies, biologicals and pharmaceuticals where precise temperature controls, maintenance and monitoring displays/ alarms are required. Mechanical Thermostat Interior Light - Excluding ARU-3004-G Three year parts and labor warranty, plus an additional two years on compressor parts LRB-26 Door Locks Additional Shelves Solid Door Conversion Casters Chart Recorders Temperature Displays LRB-33 LRB-47 Laboratory Basic Series LRB-10 10 0 C to 10 C Cycle Single Swing Glass Door 3 25 24 53 1/5 200 LRB-12 12 0 C to 10 C Cycle Single Swing Glass Door 3 25 24 62 1/5 200 LRB-19 19 0 C to 10 C Cycle Single Swing Glass Door 4 27 25 79 1/3 275 LRB-23 23 0 C to 10 C Cycle Single Swing Glass Door 4 27 30 79 1/3 355 LRB-26 26 0 C to 10 C Cycle Single Swing Glass Door 4 30 30 79 1/3 335 ARU-3004-G 30 0 C to 10 C Auto Single Swing Glass Door 5 36 34 72 1/3 372 LRB-33 33 0 C to 10 C Cycle Double Slide Glass Door 8 40 30 79 1/3 405 LRB-35 35 0 C to 10 C Cycle Double Swing Glass Door 8 40 31 79 1/3 405 LRB-37 37 0 C to 10 C Cycle Double Slide Glass Door 8 44 30 79 1/3 440 LRB-41 41 0 C to 10 C Cycle Double Slide Glass Door 8 47 30 79 1/3 450 LRB-45 45 0 C to 10 C Cycle Double Slide Glass Door 8 51 30 79 1/2 460 LRB-47 47 0 C to 10 C Cycle Double Slide Glass Door 8 54 30 79 1/2 485 LRB-49 49 0 C to 10 C Cycle Double Swing Glass Door 8 54 31 79 1/2 490 LRB-69 69 0 C to 10 C Cycle Triple Slide Glass Door 12 78 30 80 3/4 675 LRB-72 72 0 C to 10 C Cycle Triple Swing Glass Door 12 78 31 80 3/4 670 5

CHROMATOGRAPHY plus The Chromatography Plus Series Refrigerators feature a microprocessor temperature controller and display, allowing for precise temperature control, verification and recovery versus mechanical style thermostats. One interior duplex electrical outlet and two side wall port holes are provided to simplify the setup and operation of laboratory procedures. An interior fan driven, forced-draft air circulation system provides excellent temperature uniformity and recovery after door openings. Critical samples and supplies are security backed with an extensive package of audible and visual alarms. All Chromatography Plus units require two electrical outlets. Microprocessor Temperature Controller: - Digital Display - Audible and Visual High & Low Temperature Alarms - Door Ajar Alarm - Battery Back-up for audible and visual alarms - Power Failure Alarm - Sensor Error Alarm - Remote Alarm Contacts - High & Low Non-volatile Temperature Memory with reset - Audible Alarm Mute Button One GFCI protected duplex electrical outlet Two 2 access ports with spring loaded, self-closing gasketed metal covers - ARU-3004-GCP has one side-wall access port Swivel Casters (Adds 4 to unit height) Interior Light - Excludes ARU-3004-GCP Three year parts and labor warranty, plus an additional two years on compressor parts CRP-72 Locks Chart Recorders Solid Door Conversion Additional Shelves Electrical Duplex Outlet CRP-49 CRP-19 6 Chromatography Plus Series CRP-10 10 0 C to 10 C Cycle Single Swing Glass Door 3 26 24 53 1/5 220 CRP-12 12 0 C to 10 C Cycle Single Swing Glass Door 3 26 24 62 1/5 240 CRP-19 19 0 C to 10 C Cycle Single Swing Glass Door 4 28 26 79 1/3 313 CRP-23 23 0 C to 10 C Cycle Single Swing Glass Door 4 28 31 79 1/3 350 CRP-26 26 0 C to 10 C Cycle Single Swing Glass Door 4 31 31 79 1/3 355 ARU-3004-GCP 30 0 C to 10 C Cycle Single Swing Glass Door 5 36 34 79 1/3 516 CRP-33 33 0 C to 10 C Cycle Double Slide Glass Door 8 41 31 79 1/3 425 CRP-35 35 0 C to 10 C Cycle Double Swing Glass Door 8 41 32 79 1/3 420 CRP-37 37 0 C to 10 C Cycle Double Slide Glass Door 8 45 31 79 1/3 440 CRP-41 41 0 C to 10 C Cycle Double Slide Glass Door 8 48 31 79 1/3 450 CRP-45 45 0 C to 10 C Cycle Double Slide Glass Door 8 52 31 79 1/2 480 CRP-47 47 0 C to 10 C Cycle Double Slide Glass Door 8 55 31 79 1/2 505 CRP-49 49 0 C to 10 C Cycle Double Swing Glass Door 8 55 32 79 1/2 510 CRP-69 69 0 C to 10 C Cycle Triple Slide Glass Door 12 79 31 80 3/4 695 CRP-72 72 0 C to 10 C Cycle Triple Swing Glass Door 12 79 32 80 3/4 690

basic The Chromatography Basic Series Refrigerators offer a robust and reliable refrigeration system controlled by a mechanical (dial) thermostat. The Basic Series provides an economical choice for general purpose applications where the precision of a microprocessor temperature controller and security alarms are not required. These units are not intended for high-value laboratory supplies, biologicals and pharmaceuticals where precise temperature controls, maintenance and monitoring displays/alarms are required. One interior duplex electrical outlet and one side wall port hole are provided to simplify the setup and operation of laboratory procedures. All Chromatography Basic Series units require two electrical outlets Mechanical Thermostat One GFCI protected duplex electrical outlet One 2 access port with spring loaded self-closing, gasketed metal cover (right side) Interior Light - Excludes ARU-3004-GC Three year parts and labor warranty, plus an additional two year compressor parts warranty CRB-45 Locks Casters Additional Shelves Chart Recorders Temperature Displays Solid Door Conversion Electrical Duplex Outlet Access Port, 2 Diameter ( Excludes ARU-3004-GC) CRB-19 CRB-69 Chromatography Basic Series CRB-10 10 0 C to 10 C Cycle Single Swing Glass Door 3 25 24 53 1/5 215 CRB-12 12 0 C to 10 C Cycle Single Swing Glass Door 3 25 24 62 1/5 233 CRB-19 19 0 C to 10 C Cycle Single Swing Glass Door 4 28 26 79 1/3 304 CRB-23 23 0 C to 10 C Cycle Single Swing Glass Door 4 28 31 79 1/3 355 CRB-26 26 0 C to 10 C Cycle Single Swing Glass Door 4 31 31 79 1/3 335 ARU-3004-GC 30 0 C to 10 C Auto Single Swing Glass Door 5 36 34 72 1/3 373 CRB-33 33 0 C to 10 C Cycle Double Slide Glass Door 8 40 31 79 1/3 405 CRB-35 35 0 C to 10 C Cycle Double Swing Glass Door 8 40 32 79 1/3 420 CRB-37 37 0 C to 10 C Cycle Double Slide Glass Door 8 44 31 79 1/3 440 CRB-41 41 0 C to 10 C Cycle Double Slide Glass Door 8 48 31 79 1/3 450 CRB-45 45 0 C to 10 C Cycle Double Slide Glass Door 8 52 31 79 1/2 460 CRB-47 47 0 C to 10 C Cycle Double Slide Glass Door 8 55 31 79 1/2 485 CRB-49 49 0 C to 10 C Cycle Double Swing Glass Door 8 55 32 79 1/2 490 CRB-69 69 0 C to 10 C Cycle Triple Slide Glass Door 12 79 31 80 3/4 675 CRB-72 72 0 C to 10 C Cycle Triple Swing Glass Door 12 79 32 80 3/4 670 7

SOLID DOOR REFRIGERATORS plus The Solid Door Plus Series Refrigerators feature a microprocessor temperature controller, allowing for precise temperature control, recovery and maintenance versus mechanical style thermostats. Critical samples and supplies are security backed with an extensive package of temperature security and alarms. Microprocessor Temperature Controller: - Digital Display - Audible and Visual High & Low Temperature Alarms - Door Ajar Alarm - Battery Back-up for audible and visual alarms - Power Failure Alarm - Sensor Error Alarm - Remote Alarm Contacts - High & Low Non-volatile Temperature Memory with reset - Audible Alarm Mute Button Swivel Caster Platform (Adds 5 to unit height) Three year parts and labor warranty, plus an additional two years on compressor parts Chart Recorders ARU-3004-P ARU-3004-P Large Capacity Plus Refrigerators ARU-2004-P 20 0 C to 10 C Cycle Single Solid Door 4 32 32 78 1/4 258 ARU-3004-P 30 0 C to 10 C Cycle Single Solid Door 5 36 34 80 1/3 498 8

basic The Solid Door Basic Series Refrigerators provide an economical choice for general purpose applications where the precision of a microprocessor temperature controller and security alarms are not required. These units are not intended for high-value laboratory supplies, biologicals and pharmaceuticals where precise temperature controls, maintenance and monitoring displays/alarms are required. Mechanical Thermostat - Excludes ARU-1704 18 months parts and labor warranty Door Lock (for ARU-1704) Caster Platform (for ARU-2004 and ARU-3004) Solar Powered Temperature Display Battery Operated Temperature Display with High/Low Alarm ARU-3004 General Purpose Refrigerator ARU-0904 9 0 C to 10 C Cycle Single Solid Door 4 22 23 57 1/6 148 ARU-1404 14 0 C to 10 C Cycle Single Solid Door 3 28 32 60 1/4 197 ARU-1704 17 0 C to 10 C Auto Single Solid Door 4 32 30 66 1/4 210 ARU-2004 20 0 C to 10 C Cycle Single Solid Door 4 32 32 71 1/4 246 ARU-3004 30 0 C to 10 C Auto Single Solid Door 5 36 34 73 1/3 360 9

MANUAL & AUTO DEFROST FREEZERS plus Both the Manual and Auto Defrost Plus Series Freezers, featuring a microprocessor temperature controller, allow for precise temperature control, recovery and maintenance versus mechanical style thermostats. Critical samples and supplies are security backed with an extensive package of temperature security and alarms. Manual defrost units also feature five insulating inner doors and a manual defrost operating system to limit product-damaging temperature spikes. In addition to the elimination of damaging auto defrost cycles, the inner doors help reduce cold air loss during main door openings and greatly improve temperature recovery. Periodic manual defrosting is required. Microprocessor Temperature Controller: Digital Display - Audible and Visual High & Low Temperature Alarms - Door Ajar Alarm - Battery Back-up for audible and visual alarms - Power Failure Alarm - Sensor Error Alarm - Remote Alarm Contacts - High & Low Non-volatile Temperature Memory with reset - Audible Alarm Mute Button Five Insulating Inner Doors - Excludes AFP-3020 Swivel Caster Platform (upright units only; adds 5 to unit height) Three year parts and labor warranty, plus an additional two years on compressor parts MFP-3020 Chart Recorders Plus Manual Defrost Freezers MFP-2020 20-18 C to -22 C Manual 1 Solid/5 inner 4 32 32 78 1/3 314 MFP-2030 20-28 C to -32 C Manual 1 Solid/5 inner 4 32 32 78 1/3 315 MFP-3020 30-18 C to -22 C Manual 1 Solid/5 inner 4 36 34 80 1/3 464 MFP-3030 30-28 C to -32 C Manual 1 Solid/5 inner 4 36 34 80 1 462 MCFP-1520 (chest) 15-18 C to -22 C Manual Single Solid Door 2 baskets 48 29 35 1/4 196 MCFP-2020 (chest) 20-18 C to -25 C Manual Single Solid Door 3 baskets 61 30 35 1/4 230 MCFP-2520 (chest) 25-18 C to -22 C Manual Single Solid Door 3 baskets 73 30 35 1/4 264 Plus Auto Defrost Freezer AFP-3020 30-18 C to -22 C* Auto Single Solid Door 5 36 34 80 1/2 435 *Note: Auto defrost freezer models have programmed defrost cycles that will reach air temperatures of approximately 0 C 10

basic The Manual and Auto Defrost Basic Series Freezers are intended for general purpose applications where precise temperature control and maintenance are not essential and there are no requirements for temperature alarms. Manual defrost units have been designed to operate without product damaging auto defrost cycles. Periodic manual defrost is required on these units. If defrost cycles are not an issue, auto defrost units are available. Auto defrost units have programmed defrost cycles that will reach air temperatures of approximately 0 C. Mechanical Thermostat on -20 C units Microprocessor Temperature Controller on -30 C units Five insulating Inner Doors on -30 C units 18 months parts and labor warranty Solar Powered Temperature Display Caster Platform (for 20 and 30 cu. ft. upright units) Battery Powered Temperature Display with High/Low Alarm Chart Recorders MCFB-2520 MFB-3020 Standard Manual Defrost Freezers MFB-1420 14-15 C to -25 C Manual Single Solid Door 3 28 32 60 1/3 195 MFB-1720 17-15 C to -25 C Manual Single Solid Door 3 32 30 66 1/3 210 MFB-2020 20-15 C to -25 C Manual Single Solid Door 4 32 32 71 1/3 229 MFB-2030 20-27 C to -33 C Manual 1 Solid / 5 Inner 4 32 32 71 1/3 245 MFB-3020 30-15 C to -25 C Manual Single Solid Door 5 36 34 73 1/3 356 MFB-3030 30-27 C to -33 C Manual 1 Solid / 5 Inner 4 36 34 73 1 390 MCFB-1520 (chest) 15-15 C to -25 C Manual Single Solid Door 2 baskets 48 29 35 1/4 196 MCFB-2020 (chest) 20-15 C to -25 C Manual Single Solid Door 3 baskets 61 30 35 1/4 230 MCFB-2520 (chest) 25-15 C to -25 C Manual Single Solid Door 3 baskets 73 30 35 1/4 264 Standard Auto Defrost Freezers AFB-1420 14-15 C to -25 C* Auto Single Solid Door 3 28 31 60 1/4 220 AFB-1720 17-15 C to -25 C* Auto Single Solid Door 4 32 27 66 1/3 238 AFB-2020 20-15 C to -25 C* Auto Single Solid Door 4 32 32 71 1/4 245 AFB-3020 30-15 C to -25 C* Auto Single Solid Door 5 36 34 73 1/2 365 *Note: Auto defrost freezer models have programmed defrost cycles that will reach air temperatures of approximately 0 C 11

FLAMMABLE MATERIAL refrigerators & freezers Meet NFPA and OSHA guidelines 45 and 70 for the refrigerated storage of flammable (volatile) materials in general laboratory work areas. There are no electrical components located in the interior of the unit and the compressor s electrical components have been sealed in a vapor-proof enclosure for additional safety. These units are NOT designed for use in environments where volatile/explosive conditions could potentially exist. Mechanical Thermostat Adjustable temperature range, factory preset UL Listed One year parts and labor warranty Digital Temperature Display Caster Platform (20 & 30 cu. ft. units only) Additional Shelf (Refrigerator units only) FS-3020 12 Flammable Material Storage FS-1404 14 0 C to 10 C Cycle Single Solid Door 3 28 34 60 1/3 236 FS-1420 14-18 C to -25 C Manual Single Solid Door 3 28 34 60 1/3 233 FS-1704 17 0 C to 10 C Cycle Single Solid Door 3 32 32 66 1/3 264 FS-1720 17-18 C to -25 C Manual Single Solid Door 3 32 32 66 1/3 261 FS-2004 20 0 C to 10 C Cycle Single Solid Door 4 32 34 71 1/3 316 FS-2020 20-18 C to -25 C Manual Single Solid Door 4 32 34 71 1/3 313 FS-3004 30 0 C to 10 C Cycle Single Solid Door 5 36 36 73 1/3 381 FS-3020 30-18 C to -25 C Manual Single Solid Door 5 36 36 73 1/3 378 FS-RFC-30 30 Avg. 4 C/-20 C Cycle /Manual Single Ext./ Single Int. 3 36 36 73 1/3 396 Flammable Material Storage with built-in Digital Temperature Display FS-1404-DTD 14 0 C to 10 C Cycle Single Solid Door 3 28 34 60 1/3 236 FS-1420-DTD 14-18 C to -25 C Manual Single Solid Door 3 28 34 60 1/3 233 FS-1704-DTD 17 0 C to 10 C Cycle Single Solid Door 3 32 32 66 1/3 264 FS-1720-DTD 17-18 C to -25 C Manual Single Solid Door 3 32 32 66 1/3 261 FS-2004-DTD 20 0 C to 10 C Cycle Single Solid Door 4 32 34 71 1/3 316 FS-2020-DTD 20-18 C to -25 C Manual Single Solid Door 4 32 34 71 1/3 313 FS-3004-DTD 30 0 C to 10 C Cycle Single Solid Door 5 36 36 73 1/3 381 FS-3020-DTD 30-18 C to -25 C Manual Single Solid Door 5 36 36 73 1/3 378

In addition to the base offering of flammable material storage refrigerators and freezers, select units with digital displays, alarms, and chart recorders are also available. These units meet NFPA and OSHA guidelines 45 and 70 for the refrigerated storage of flammable (volatile) materials in general laboratory work areas. There are no electrical components located in the interior of the unit and the compressor s electrical components have been sealed in a vapor-proof enclosure for additional safety. These units are NOT designed for use in environments where volatile / explosive conditions could potentially exist. Mechanical Thermostat Digital Temperature Display Audible and Visual Alarm Package Remote Alarm Contacts UL Listed One year parts and labor warranty FS-2020-DA-CR Caster Platform Additional Shelf (Refrigerator units only) FS-2004 DTD FS-3004-DA Flammable Material Storage with built-in Digital Temperature Display and Alarm FS-2004-DA 20 0 C to 10 C Cycle Single Solid Door 4 32 34 78 1/3 356 FS-2020-DA 20-18 C to -25 C Manual Single Solid Door 4 32 34 78 1/3 353 FS-3004-DA 30 0 C to 10 C Cycle Single Solid Door 5 36 36 80 1/3 421 FS-3020-DA 30-18 C to -25 C Manual Single Solid Door 5 36 36 80 1/3 418 Flammable Material Storage with built-in Digital Temperature Display, Alarm, and Chart Recorder FS-2004-DA-CR 20 0 C to 10 C Cycle Single Solid Door 4 32 34 78 1/3 356 FS-2020-DA-CR 20-18 C to -25 C Manual Single Solid Door 4 32 34 78 1/3 353 FS-3004-DA-CR 30 0 C to 10 C Cycle Single Solid Door 5 36 36 80 1/3 421 FS-3020-DA-CR 30-18 C to -25 C Manual Single Solid Door 5 36 36 80 1/3 418 13

HAZARDOUS LOCATION refrigerators & freezers Meet NFPA and OSHA guidelines for Hazardous Locations, Class 1, Division II, Group C & D. These units are engineered for use in environments where volatile / explosive conditions could potentially exist. They are not intended for common lab / room environments that are not designed to be explosion proof (See: Flammable Material units). Units are designed with no internal electrical components and all external components are sealed per NFPA and OSHA guidelines. Units must be hard wired in conduit to 120VAC power source. Power cords with plugs are NOT ACCEPTABLE. Exterior Adjustable Mechanical Thermostat sealed in UL Listed Explosion Proof Box UL Listed One year parts and labor warranty Caster Platform (20 & 30 cu. ft. units only) Additional Shelf (Refrigerator units only) EP-3020 EP-RFC-30 Explosion Proof Storage EP-1404 14 0 C to 10 C Cycle Single Solid Door 3 28 34 65 1/3 248 EP-1420 14-18 C to -25 C Manual Single Solid Door 3 28 34 65 1/3 245 EP-1704 17 0 C to 10 C Cycle Single Solid Door 3 32 32 71 1/3 276 EP-1720 17-18 C to -25 C Manual Single Solid Door 3 32 32 71 1/3 273 EP-2004 20 0 C to 10 C Cycle Single Solid Door 4 32 34 76 1/3 328 EP-2020 20-18 C to -25 C Manual Single Solid Door 4 32 34 76 1/3 325 EP-3004 30 0 C to 10 C Cycle Single Solid Door 5 36 36 78 1/3 393 EP-3020 30-18 C to -25 C Manual Single Solid Door 5 36 36 78 1/3 390 EP-RFC-30 30 0 C to 10 C/-18 C to -25 C Cycle/Manual Single Ext./Single Int. 3 36 36 78 1/3 408 14

STAINLESS STEEL The Stainless Steel Laboratory Series Refrigerators feature a microprocessor temperature controller, allowing for precise temperature control, recovery and maintenance versus mechanical style thermostats. Critical samples and supplies are security backed with an extensive package of temperature security and alarm features. Microprocessor Temperature Controller: - Digital Display - Audible and Visual High & Low Temperature Alarms - Remote Alarm Contacts Stainless Steel Exterior Swivel Casters (Adds 7 to unit height) 18 months parts and labor warranty Additional Shelves 23SS-GP 49SS-GP Plus Stainless Steel Laboratory Refrigerators 23SS-GP 23 0 C to 10 C Cycle Single Solid Door 3 27 33 78 3/8 390 49SS-GP 49 0 C to 10 C Cycle Double Solid Door 6 54 33 78 1/2 558 15

UNDERCOUNTER plus refrigerators & freezers The Undercounter Plus Series Refrigerators and Freezers, featuring a microprocessor temperature controller and display, allow for precise temperature control, verification and recovery versus mechanical style thermostats. An interior fan driven, forced-draft air circulation system provides excellent temperature uniformity and recovery after door openings. Critical samples and supplies are security backed with an extensive package of audible and visual alarms. The freezer units feature a manual defrost operating system to limit product-damaging temperature spikes found in auto defrost units. Periodic manual defrosting is required. The Undercounter Built-in models ( UCBI ) are designed with a front-breathing ventilation system, eliminating the need for clearance around the top and sides of the unit; enabling the user to incorporate these units into cabinets and other applications where free space is limited. Freestanding models ( UCFS ) require 4 of clearance around back and sides of the unit for proper ventilation. Improper installation will void the warranty and will lead to temperature maintenance issues, overheating and possible failure. Microprocessor Temperature Controller: - Digital Display - Audible and Visual High & Low Temperature Alarms - Remote Alarm Contacts White Powder Coat Paint or Stainless Steel Exterior Two years parts and labor warranty UCBI-0404G UCBI-0420 UCBI-0404SS Plus Undercounter Refrigerators & Freezers UCFS-0204 2.5 0 C to 10 C Cycle Single Solid Door 3 18 19 29 1/7 108 UCFS-0204G 2.5 0 C to 10 C Cycle Single Glass Door 3 18 19 29 1/7 108 UCFS-0504G 5.2 0 C to 10 C Cycle Single Glass Door 3 24 24 32 1/5 133 UCBI-0404 4.6 0 C to 10 C Cycle Single Solid Door 3 24 25 33 1/3 137 UCBI-0404G 4.6 0 C to 10 C Cycle Single Glass Door 3 24 26 33 1/3 137 UCBI-0420 4.2-15 C to -25 C Manual Single Solid Door 2 24 25 33 1/3 148 UCBI-0404SS 4.5 0 C to 10 C Cycle Single Solid Door 3 24 25 33 1/3 140 UCBI-0420SS 4.2-15 C to -25 C Manual Single Solid Door 2 24 25 33 1/3 140 UCBI-0404G-ADA 4.6 0 C to 10 C Cycle Single Glass Door 3 24 26 32 1/3 137 UCBI-0420-ADA 4.2-15 C to -25 C Manual Single Solid Door 2 24 25 32 1/3 148 16

basic The Undercounter Basic Series Refrigerators and Freezers are intended for general purpose applications only where precise temperature control and maintenance are not essential and there are no requirements for temperature alarms. Freezers feature a manual defrost operating system to limit product-damaging temperature spikes found in auto defrost units. Periodic manual defrosting is required. Warning: These units are not designed for built-in and/or enclosed installations. Improper installation will void the warranty and will lead to temperature maintenance issues, overheating and possible failure. Mechanical Thermostat White Powder Coat Paint One year parts and labor warranty Solar Powered Temperature Display Battery Operated Temperature Display with High/Low Alarm Stacking Kit UCFS-0504W UCFS-0420W Shown with optional temperature display and alarm UCFS-0220M General Purpose Undercounter Refrigerators & Freezers UCFS-0504W 4.6 0 C to 10 C Cycle Single Solid Door 3 22 23 34 1/7 109 UCFS-0220M 1.5-15 C to -25 C Manual Single Solid Door 1 19 20 20 1/10 50 UCFS-0420W 4-15 C to -25 C Manual Single Solid Door 3 (drawers) 22 23 34 1/7 107 17

COMBINATION UNITS plus The Combination Plus Series units feature refrigerators (and freezers in select models) with a microprocessor temperature controller allowing for precise temperature control, verification and recovery. An interior fan driven, forced-draft air circulation system provides excellent temperature uniformity and recovery after door openings. All models are equipped with digital temperature displays for convenient monitoring. Critical samples and supplies are security backed with an extensive package of audible and visual alarms. The freezer units feature a manual defrost operating system to limit product-damaging temperature spikes found in auto defrost units. Periodic manual defrosting is required. The RFC-9P and RFC-9SSP models are designed with a front-breathing ventilation system, eliminating the need for clearance around the top and sides of the unit; enabling the user to incorporate these units into cabinets and other applications where free space is limited. All other models require 4 of clearance around back and sides of the unit for proper ventilation. Improper installation will void the warranty and will lead to temperature maintenance issues, overheating and possible failure. Microprocessor Temperature Controller: - Digital Display - Audible and Visual High & Low Temperature Alarms - Remote Alarm Contacts 120 VAC Operation Requires two outlets - Excludes refrigerators on RFC-12P or RFC-14P White Powder Coat Paint or Stainless Steel Exterior Two years parts and labor warranty RFC-14P Additional Shelves (for RFC-12P or RFC-14P) Casters (for RFC-12P or RFC-14P) Solid Door Conversion RFC-9P RFC-9SSP 18 Premier Combination Refrigerator/Freezer RFC-4P 4 0 C to 10 C /-15 C to -25 C Cycle/Manual Dbl. Ext. Doors (Solid & Glass) 4 19 20 48 1/7 154 RFC-7P 7 0 C to 10 C /-15 C to -25 C Cycle/Manual Dbl. Ext. Doors (Solid & Glass) 4 24 24 52 1/5 179 RFC-9P 9 0 C to 10 C /-15 C to -25 C Cycle/Manual Dbl. Ext. Doors (Solid & Glass) 5 24 26 67 1/3 245 RFC-9SSP 9 0 C to 10 C /-15 C to -25 C Cycle/Manual Dbl. Ext. Doors (Stainless Steel) 5 24 25 67 1/3 240 RFC-12P 12 0 C to 10 C /-15 C to -25 C Cycle/Manual Dbl. Ext. Doors (Solid & Glass) 4 25 24 73 1/5 261 RFC-14P 14 0 C to 10 C /-15 C to -25 C Cycle/Manual Dbl. Ext. Doors (Solid & Glass) 4 25 24 82 1/5 281

basic The Combination Basic Series units are intended for general purpose applications only where precise temperature control and maintenance are not essential and there are no requirements for temperature alarms. Select models have freezers which feature a manual defrost operating system to limit product-damaging temperature spikes found in auto defrost units. Periodic manual defrosting is required. Models with auto defrost freezer compartments have programmed defrost cycles that will reach air temperatures of approximately 0 C. Most Combination Basic Series units will require 2 outlets (see Standard Features below for exceptions). Mechanical Thermostat 120 VAC Operation - Requires two outlets (except models ending in A or M ) - Excludes RFC-3M, RFC-12B, RFC-14B, RFC-17A, RFC-20A White Powder Coat Paint One year parts and labor warranty RFC-12M Solar Powered Temperature Display Battery Operated Temperature Display with High/Low Alarm (not standard on RFC-3M, RFC-12B, RFC-14B, RFC-17A, RFC-20A) RFC-10B RFC-12B General Purpose Combination Refrigerator/Freezer RFC-3M 3 1 C to 8 C/ -8 C to -21 C Cycle/Manual Dbl. Ext. Solid Doors 2 19 21 34 1/6 100 RFC-6B 6 0 C to 10 C/ -15 C to -25 C Cycle/Manual Dbl. Ext. Solid Doors 4 22 23 53 1/7 155 RFC-8B 8 0 C to 10 C/ -15 C to -25 C Cycle/Manual Dbl. Ext. Solid Doors 6 22 23 67 1/7 176 RFC-10B 10 0 C to 10 C/ -15 C to -25 C Cycle/Manual Dbl. Ext. Solid Doors 5 22 23 76 1/6 194 RFC-12B 12 0 C to 10 C/ -15 C to -25 C Cycle/Manual Dbl. Ext. Doors (Solid & Glass) 4 25 24 73 1/5 261 RFC-12M 12 1 C to 10 C/ -7 C to -17 C Cycle/Manual Dbl. Ext. Solid Doors 6 24 25 62 1/5 161 RFC-14B 14 0 C to 10 C/ -15 C to -25 C Cycle/Manual Dbl. Ext. Doors (Solid & Glass) 4 25 24 82 1/5 281 RFC-16M 16 1 C to 10 C/ -7 C to -27 C Cycle/Manual Dbl. Ext. Solid Doors 6 28 26 73 1/5 198 RFC-17A 17 1 C to 9 C/ -10 C to -15 C* Cycle/Auto Dbl. Ext. Solid Doors 3 28 32 65 1/4 230 RFC-20A 20 1 C to 9 C/ -10 C to -15 C* Cycle/Auto Dbl. Ext. Solid Doors 4 30 34 69 1/4 260 RFC-30M 30 2 C to 8 C/ -15 C to -20 C Cycle/Manual Single Ext. / Single. Int. 3 36 36 73 1/3 383 *Note: Auto defrost freezer models have programmed defrost cycles that will reach air temperatures of approximately 0 C 19

about us LRP has a long tradition of excellence with repeat customers who have come to expect quality products and service. All of our compressors and temperature controllers are the latest in today s technology. Our commitment to innovation combined with 50 years of refrigeration manufacturing experience allow us to offer a complete line of refrigerators and freezers to satisfy customer needs for a wide variety of applications. customer service What sets LRP apart from other manufacturers is our dedication to the customer. Our well-trained staff of Customer Service representatives collaborate with our manufacturer s representative groups across the country to properly identify products that will best serve a customer s application. In addition, our highly qualified Technical Service representatives work closely with a national network of trained service companies to back a warranty plan that is second to none. These qualities come together to form a cohesive system of support before, during and after the sale. For more information, contact us today: Lab Research Products 125 Varnfield Drive Summerville, SC 29483 1 (800) 648-4041 www.labresprod.com info@labresprod.com 20