Conduction Cooling Techniques for Rugged Computers

Similar documents
CHOOSING THE RIGHT COOLING METHODOLOGY

Experion LX Direct Station Specification

Aerospace/ Military Thermal Management Systems Selection Guide

How to Select an Industrial PC with I/O for a Wide Temperature Application

Advanced Laundry Chemical Dosing System for Single and Multi-Washers

Sensor Interface Module Installation/Operation Instructions

DOG2 MEMS SERIES CAN J1939 INCLINOMETER

Selecting Honeywell Board Mount Pressure Sensors

Dräger VVP 1000 System Components

MODEL 4000A & 4001A ACCELEROMETER

PROCESS AUTOMATION TIME TO RELAX ADVANCED DIAGNOSTICS EXPERT SYSTEM AT WORK

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated)

SAFETY MANAGER SC Ensure safety, simplify operations and reduce lifecycle costs

Technical Development Program. Honeywell Training Services

Dräger Pac 8500 Single-Gas Detection Device

The best in connector value... today, tomorrow and into the future!

RTD TEMPERATURE SENSING SYSTEM

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

LSM Quadrant Source and Measure Unit for LED Production Tests. Two Global Leaders. One Complete Solution.

The Importance of Pressure Sensors in HVACR Systems

CSI Master Format 2004 Guide Specification for: Snow Melting (Mineral Insulated)

MSP100 Pressure Transducer

Dräger Pac 6000 Single-Gas Detection Device

15203B 25203B 35203B Uniaxial Biaxia Triaxial

Balancing & Control. Frese OPTIMIZER. Pressure Independent 4-pipe Coil Control Unit

Arun Nayar Senior Vice President, Finance and Treasurer

Empowering Your Vision

Screw Compressors SM SERIES. Capacities from: 16 to 54 cfm Pressures from: 80 to 217 psig

Dräger Pac 8000 Single-Gas Detection Device

fuel leak detection find leaks before they find you

Terminal Automation Solutions

U5600. Wireless Pressure Transducer SPECIFICATIONS

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

TE S RAYCHEM PLUG-IN TERMINATIONS (RPIT) INNER CONE SYSTEMS FOR SWITCHGEARS AND TRANSFORMERS UP TO 52 kv

Company Presentation

HPF 1.2 NEW INTERCONNECTION SYSTEM FOR EXTREME VIBRATION REQUIREMENTS IN THE VEHICLE

INDUSTRY APPLICATIONS

Airflow Sensors Line Guide

Supervisor Standard Edition

SAVING LIVES THROUGH RELIABLE AND INNOVATIVE TECHNOLOGY. Medical Refrigeration

Manufacturing Notes for RFPA2016

Honeywell Zephyr Analog Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

MODEL 834M1 ACCELEROMETER

"SAN ACE MC" for Pentium *

Heraeus Sensor Technology. Precise and reliable measurement, optimization and management Sensors for the efficient and responsible use of resources

6600 SERIES 8-Pin DIP, Subminiature Bimetal Disc Thermostat

Sensing and Control. Figure 1. SMART Position Sensor, 100 and 180 Arc Configurations

Connections. Application Note Jeronimo Rd. Irvine, CA February 20, 2008 Document Number AN0108, Rev A.1

DEFENDI Burning innovation

Tie-bar-less for maximum quality and efficiency

HTF3000LF PVH-3.3 TEMPERATURE AND HUMIDITY MODULE

Four-Door Access Controller User s Manual

PRODUCT TRAINING MODULE: Honeywell Zephyr Airflow Sensors HAF Series High Accuracy

RAYCHEM SCREENED SEPARABLE CONNECTORS RSTI FOR SWITCHGEARS AND TRANSFORMERS IN MEDIUM VOLTAGE DISTRIBUTION NETWORKS

LEVEL SENSED DRAINS KAPTIV-MD KAPTIV-CS KAPTIV-CS-HP 50 KAPTIV-CS-HP 500 NUFORS-CR MAGY-UL

Pulp & Paper Solution. Pulp & Paper Solution. Instruments and Solution for Pulp & Paper Industry LF3BUSS03-00EN.

PACIFIC INSIGHT ELECTRONICS CORP Pacific Insight Electronics Corp.

Z-PACK TinMan 85 ohm Connector Overview

Figure 1 TWM1000 Electromagnetic Flow Converter. 1. Large, illuminated graphic display with intuitive operation 2. For AC and DC operation

Liebert CW kW. Chilled Water Cooled Precision Air Conditioning For Data Centers. Precision Cooling For Business-Critical Continuity

39G Air Handling Unit

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

RFSW6132. Manufacturing Notes. Table of Contents. 1 Introduction... 2

KAPTIV-MD KAPTIV-CS KAPTIV-CS-HP NUFORS-CR MAGY-UL MAGY COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS LEVEL SENSED DRAINS

Dräger VentStar Helix heated (N) plus Consumables and Accessories

Access control hardware portfolio

Terminal Automation Solutions SmartRadar FlexLine Global Experience. Locally Applied.

Longline Heating. Contents. Introduction

Dräger PointGard 2100 Detection of toxic gases and vapours

CPS V Cabinet Power System

MULTICELL... for HIGH-TEMP TUBULAR HEATER TYPICAL CARTRIDGE HEATER WATLOW MULTICELL HEATER TYPICAL TUBULAR HEATER

FAST, INTELLIGENT FIRE ALARM SYSTEMS THAT DELIVER IT ALL

TIMER CONTROLLED DRAINS

Screw Compressors AS SERIES. Capacities from: 59 to 124 cfm Pressures from: 80 to 217 psig

HM1500LF Relative Humidity Module

Page 1. Brussels, 11 October europacable Rue Marie de Bourgogne 58 B-1000 Brussels EU Transparency Register ID

XRAY SHARK XBD50/XBD51 X-Ray Inspection System for Glass-in-Glass Detection

Airflow Sensors Line Guide

MEMS Accelerometer ICs. AMR Magnetic Sensor ICs. Gas Flow Modules. Differential Pressure Sensors. Tilt Modules. Current Sensors

Elenco delle Norme CENELEC rese disponibili nel mese di Marzo 2017

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM. Datasheet

Nardalert S3 TM Non-Ionizing Radiation Monitor

ED-18 Analog Output Series Magnetic Encoder SPECIFICATIONS

laundry Laundry dosing systems

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Above Ground Greasy Waste Disposal Lines

Modular Fire Panel 5000 Series Just as flexible as your plans

Packaging in Consumer Goods

PROCESS AUTOMATION PROTECTING YOUR PROCESS THE DEFINITION FOR INTRINSIC SAFETY K-SYSTEM K-SYSTEM THE MOST TRUSTED NAME.

The 7 attributes of highly effective quick disconnect couplings for liquid cooling of computers and servers

Surface and Ambient Sensing Thermostats VE and C8 Series

Two global companies, one solution.

Aspirated Smoke Detectors

FSS-SMT Series. Low Profile Force Sensor

Safer. Smarter. Tyco. EAS: We reinvent it every day.

Is your current safety system compliant to today's safety standard?

Dräger Pac 7000 Single-Gas Detection Device

89BSD Digital Output

LOW VOLTAGE HEAT SHRINK JOINTS TECHNOLOGY CONNECTING YOUR NEEDS TO TOMORROW S NETWORKS

Transcription:

Conduction Cooling Techniques for Rugged Computers If it s embedded, it s Kontron.

Conduction Cooling Techniques for Rugged Computers Conduction cooling for modular embedded computers have been used for many years in applications where air cooling is not appropriate. Standardization efforts in that domain have early helped to maintain interoperability of COTS products. The conduction cooled design techniques are continuously improving to meet the requirements for higher power dissipation and lower price. Contents Conduction Cooling Techniques for Rugged Computers................ 1 Summary................................................ 2 Contents................................................. 2 Why using conduction cooled board computers..................... 3 COTS approach to conduction cooled modular computers............... 3 Further refinements for conduction cooled heat drain................. 4 Extending the thermal performance with heat pipes.................. 4 Author s Bio.............................................. 4 About Kontron............................................. 5

Why using conduction cooled board computers Conduction cooled boards have traditionally been employed in applications where heat evacuation with an airflow is impractical. These include situations where there is no air available such as space applications, where the air is not efficient enough to carry all the calories at the right speed. This also includes environments where creating an airflow with moving parts would affect the reliability of the system. Computers running in harsh environments can often benefit from conduction cooled techniques. Extended board temperature specifications, for example between -40 and 85 C, require optimized thermal performance to lower the temperature difference between the silicon dies and the environment. But also, their reliability is often critical and the high level of shocks and vibrations would prohibit the use of fans. Another situation where conduction cooling is helpful, is the design of a sealed computer box to avoid exposing the electronics to dust or contaminant, for example kerosene vapours. COTS approach to conduction cooled modular computers COTS mechanical rules for conduction cooled modular board computers in the eurocard form factor were standardized in 1992 by IEEE Std 1101.2-1992 in order to ensure interoperability and common good practices. Thanks to this standard, conduction cooled boards and chassis selected from different vendor catalogues all work together. This IEEE standard mainly defines the mechanical dimensions and thermal interfaces for eurocards like VMEbus or other form factors such as CompactPCI. It was originally intended to evacuate the heat to the chassis from the bottom of the PCB plugged in module and along the card guides. In that case, the PCB is designed with an embedded conductive layer in order to move the calories toward the PCB edges. As the thermal dissipation requirements increase, this thermally conductive PCB layer is often replaced with a metal drain, machined from aluminium, which covers the whole top side of the board. And any direct contact of the electronic components is through a thermal paste. This technique, sometimes called the ruggedizer, not only improves thermal performance, but also helps to sustain a high level of shock and vibration by providing a rigid frame to attach the board at multiple points. It also helps the board vendors to offer the same electronic design in a standard air cooled and conduction cool version. The only penalty to the standard air cooled design being not to place components too close to the card guide area. Figure 1 shows the Kontron PowerEngine7 board running at up to 1 GHz, as an example of the ruggedizer which is compatible with IEEE Std 1101.2. Figure 1: Conduction cooled board computer compatible with IEEE Std 1101.2: PowerEngine7 from Kontron The wedge lock mechanism along the card guides, defined in the norm, secures the card inside the chassis and applies pressure on the thermal interface between the drain and guide in order to improve the thermal performance. In addition to IEEE Std 1101.2, other international standards are available to define the conduction cooled practices for modular computers, such as VITA 47 and VITA 20. ANSI/VITA 47-2005[R2007]. These standards normalize the different severity level of environments for air cooled, conduction cooled, liquid cooled and spray cooled boards. Related standards not addressed in this paper, and specifying conduction cooled implementations for Eurocard, are VITA 48 describing VPX VITA 46 mechanical implementations and VITA 57 dealing with FMC mezzanines. ANSI/VITA 20-2001[R2005] defines the rules for designing conduction cooled PMC mezzanine cards and their associated mother boards. The heat of the daughter cards is propagated to the motherboard through two mandatory thermal bars and two optional thermal ribs, arranged on Figure 2 representing a conduction cooled graphics card, the Kontron XMC-G72. This graphics card, engineered for air cooled and conduction cooled environment, features a state of-theart dual display capability based on ATI HD2400 graphics processor. Figure 2: Conduction cooled graphics PMC mezzanine, the Kontron XMC-G72.

Further refinements for conduction cooled heat drain To limit the cost of qualifications and inventories, modular boards offered in both air cooled and conduction cooled versions, are sometimes build from a mixed PCB outline allowing both types of cooling. This is illustrated in Figure 3 with the Kontron ITC-320, a single or dual core processor board featuring an Intel Core 2 Duo, Core Duo or Intel Celeron M processor in the 3U CompactPCI form factor. Figure 4: PowerNode5 dual PowerPC processor board running at 1.6 GHz in conduction cooled environment Figure 3: The Kontron ITC-320 Intel Core 2 Duo processor board It can also be noted on Figure 3 that half of the wedge lock mechanism is integrated inside the thermal drain. This feature reduces the thermal impedance of the drain to the chassis by increasing the section of the thermal path available to conduct the heat. In other words, it allows to reduce the component keep out area along the sides of the card while increasing the thermal conductivity. Extending the thermal performance with heat pipes For the highest thermal dissipation and thermal density, heat pipes can be very effective in conduction cooled environments. Figure 4 shows the Kontron PowerNode5 processor board which features two 64 bits PowerPC processors running at 1.6 GHz in a conduction cooled environment. The calories generated by each processor with a significant thermal density are evacuated through two heat pipes towards each side of the board. The first benefit of this is to take advantage of the extraordinary high thermal conductivity of heat pipes as compared to passive metal. The second benefit of these heat pipes is that they provide a floating copper caps to contact the dissipating die with precision, limiting heat losses at the die thermal interface. It should be noted that the heat pipes are arranged in a symmetrical topology from the die, allowing the assembly to be less sensible to gravity or acceleration. Regardless of the card orientation, if one heat pipe becomes less efficient because of acceleration or gravity, the symmetrical heat pipe will compensate through improved thermal performance. This compensation effect has been clearly validated by testing the equipment in a centrifuge. Another key feature of the heat pipes is the capability to pre heat a device cooled by a heat pipe up to a temperature that is compliant to its specification before applying the power to the board. When the board is at very low temperature, the heat pipe internal liquid is frozen, hence, it is easier to heat the die with an external device with a good efficiency since the thermal path to the cold wall is blocked. Note to Readers: Some of the characteristics described in this article are protected through pending patents of Kontron. Author s Bio Serge Tissot, Manager of the Board Computers department of Kontron Modular Computers S.A.S. 4

About Kontron Kontron designs and manufactures standard-based and custom embedded and communications solutions for OEMs, systems integrators, and application providers in a variety of markets. Kontron engineering and manufacturing facilities, located throughout Europe, North America, and Asia-Pacific, work together with streamlined global sales and support services to help customers reduce their time-to-market and gain a competitive advantage. Kontron s diverse product portfolio includes: boards and mezzanines, Computer-on-Modules, HMIs and displays, systems, and custom capabilities. Kontron is a Premier member of the Intel Embedded and Communications Alliance. The company is a recent three-time VDC Platinum vendor for Embedded Computer Boards. Kontron is listed on the German TecDAX stock exchange under the symbol KBC. For more information, please visit: Corporate Offices Europe, Middle East & Africa Oskar-von-Miller-Str. 1 85386 Eching/Munich Germany Tel.: +49 (0)8165/ 77 777 Fax: +49 (0)8165/ 77 219 sales@kontron.com North America 14118 Stowe Drive Poway, CA 92064-7147 USA Tel.: +1 888 294 4558 Fax: +1 858 677 0898 sales@us.kontron.com Asia Pacific 17 Building,Block #1,ABP. 188 Southern West 4th Ring Road Beijing 100070, P.R.China Tel.: + 86 10 63751188 Fax: + 86 10 83682438 kcn@kontron.cn #Whitepaper - Conduction Colling Techniques for Rugged Computers# 27012009PDL All data is for information purposes only and not guaranteed for legal purposes. Subject to change without notice. Information in this datasheet has been carefully checked and is believed to be accurate; however, no responsibilty is assumed for inaccurancies. All brand or product names are trademarks or registered trademarks of their respective owners. 5