WALL CONTROLS MAIN CONTROLS

Similar documents
WALL CONTROLS MAIN CONTROLS

WALL CONTROLS MAIN CONTROLS

HEAT RECOVERY VENTILATORS MODELS AVS HRV EKO 1.5, AVS CONSTRUCTO 1.5V, NOVOFIT 1.0 AND ENERGY RECOVERY VENTILATOR MODEL AVS ERV EKO 1.

Indoor Air Quality Product Brochure.

User Manual HEAT RECOVERY VENTILATORS 1000 HE HE HE HE HE HE COMPACT 5585 COMPACT READ AND SAVE THESE INSTRUCTIONS.

READ AND SAVE THESE INSTRUCTIONS

USER GUIDE HEAT RECOVERY VENTILATORS MODELS HRV 90H-V ECM, 90H-V AND 60H NOVO+, MODEL ERV 90H-V ECM PLEASE READ AND SAVE THESE INSTRUCTIONS

VIGÖR HRV PLUS AND VIGÖR ERV

HEAT RECOVERY VENTILATOR

Address of your installer

HEAT RECOVERY VENTILATORS MODELS HRV 90H-V ECM, 90H-V

Indoor Air Quality Product Brochure.

HEAT RECOVERY VENTILATORS HRV 60H ERV 60H. User Guide AND ENERGY RECOVERY VENTILATORS. Model no.: (HRV with ports on top)

Your complete source of information on Venmar AVS air exchangers. Constructo: 1.0 / 1.5 / 2.0 Solo: 1.5 / 2.0 Duo: 1.2 / 1.4 / 1.9 HE: 1.3 / 1.8 / 2.

HEAT RECOVERY VENTILATORS MODELS AVS E15 ECM HRV, AVS E15 HRV, AVS E10 HRV AND ENERGY RECOVERY VENTILATOR MODEL AVS E15 ECM ERV

ENERGY RECOVERY VENTILATOR

The best way to enhance indoor air quality

INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.

INSTALLATION GUIDE VB0180 VB0148

Heat Recovery Ventilators models:

HEAT RECOVERY VENTILATORS AND ENERGY RECOVERY VENTILATORS CONSTRUCTO 1.0 MODELS: Model no.: (HRV with ports on top)

Light commercial models

USER GUIDE MODELS ERV CONSTRUCTO 1.5 QUATTRO ERV CONSTRUCTO 2.0 QUATTRO READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY rev.

HOME OWNERS GUIDE ERV MODEL PE 7.15 PE SS Product of Imperial Air Technologies

Purify your world Bring a breath of fresh air to your business with vänee light commercial ERV and HRV solutions the energy-efficient choice for

INSTALLATION GUIDE. Horizontal series. HRV MODEL 8160 and MODEL 8220 ERV MODEL 3160 and MODEL 3220

Evolution Control. Zone Control Homeowner s Guide

INSTALLER AND USER MANUAL VENTILATION SYSTEM

Ventilation Solutions IAQ Canada

YEAR-ROUND COMFORT EVOLUTION CONTROL ZONE CONTROL HOMEOWNER S GUIDE. The Ultimate Home Comfort System.

BRONZE MODELS 90H* 190H READ AND SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTIONS AND USER GUIDE

ERV-24. Technician Settings & Operating Manual. Protected by one or more of the following patents: US 5,547,017; 5,881,806; 6,431,268; CA 2,245,135

INSTALLATION GUIDE FOR AVS HRV EKO 1.5, AVS CONSTRUCTO 1.5V, HRV 90H-V ECM AND 90H-V UNITS

INDOOR AIR QUALITY KITS AND ACCESSORIES /12 Supersedes 05/12

VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits

INDOOR AIR QUALITY KITS AND ACCESSORIES /2014. Supersedes 06/2014

SER Series. fantech. Installation Manual. Energy Recovery Ventilators. ser 1504 ser 1504n ser 2004 ser 2004n ser 3204d ser 3204n

Residential and Commercial HRVs & ERVs. Heat Recovery Ventilators & Energy Recovery Ventilators

VENMAR AVS INSTALLATION GUIDE AVS E15 ECM ERV* AVS E15 ECM HRV* AVS E15 HRV AVS E10 HRV 90H-V ECM ERV* 90H-V ECM HRV* 90H-V+ 60H-V+ VÄNEE

IAQ VENTILATION SOLUTIONS

Residential Heat & Energy Recovery

VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits

TR Series - The Ultimate ERV

Condensation on Your Windows?

InspirAIR Compact Heat and Energy Recovery. Multi-Family HRV/ERV

Slimline Curve Electric Radiator. Step by Step Programming Guide

Novofit 2.0 (Part no )

ETN-24-HC21-PROG Econo-Vent

Max Series 5 Speed Electronics Lifestyle MAX Digital Control included

SER150. Installation Manual. Energy Recovery Ventilators

Residential and Commercial HRVs & ERVs. Heat Recovery Ventilators & Energy Recovery Ventilators

Product Data VA3B VB5B VC5B. Heat Recovery Ventilators

SER Series. Installation Manual. Energy Recovery Ventilators SER 1504 SER 2004 SER 3204D

BETTER AIR. BETTER LIFE.

DAY/TIME Button: Selects hour, minute and day setting.

Operation GT7000. Time / Current Temp. TEMP UP button. Display. Fan. Switch. Set Temp. Display. Mode Switch. Backlight. TEMP DOWN button.

Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics. RNC Series. Residential Heat Recovery Ventilators (HRV)

INSTALLATION GUIDE FOR VENMAR AVS UNIT CONSTRUCTO 1.0 HRV AND CONSTRUCTO 1.0 ERV

Infinity Control. Homeowner s Guide. The New Feeling of Comfort

Maintenance Matters. Maintaining Your Heat Recovery Ventilation System

IAQ VENTILATION SOLUTIONS

Heat or Energy Recovery Ventilation System

DAY/TIME Button: Selects hour, minute and day setting.

Operation 8085C ENGLISH. Customer Support: or Visit our webiste Printed in China

WARNING Important Safety Information

Put the V back in HVAC

WARNING Important Safety Information

READ CAREFULLY AND SAVE R3

Smart thermostat with Humidification/De-humidification control

Smart Temp. Model

ATC32U01 igate Communicating, Programmable Thermostat

Product Data A05229 A05330 HRV

INSTALLATION GUIDE FOR VENMAR AVS CONSTRUCTO 1.5* AND CONSTRUCTO 2.0

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION. Premier Series

IT801 Thermostat. User s Manual. The complete guide to the set up and operation of your new smart Wi-Fi thermostat.

USER MANUAL WARNING! CONTENTS MODEL SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING

Peak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat.

WARNING Important Safety Information

OPERATION GUIDE MODEL CERV-001-PARTA, CERV-001-PARTB CONDITIONING ENERGY RECOVERY VENTILATOR (CERV)

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

Programmable Thermostat

Ventilation Solutions IAQ Canada

aura-t TP536/EU ventilation systems

TC-NHP01-A, TC-NAC01-A Comfort Series Non- Programmable Thermostat. Owner s Manual

INSTALLATION MANUAL MODELS ERV CONSTRUCTO 1.5 QUATTRO ERV CONSTRUCTO 2.0 QUATTRO READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY

VENTILATORS VH30100 COMPACT HEAT RECOVERY VENTILATOR VE30100 COMPACT ENERGY RECOVERY VENTILATOR. Installation and Operation Manual.

INSTALLATION GUIDE FOR VENMAR AVS UNITS CONSTRUCTO 1.0 HRV AND CONSTRUCTO 1.0 ERV

GreenCon On/Off Room Thermostat

HEAT PUMP PROGRAMMABLE THERMOSTAT

BACnet Points for Single Compressor Water-to- Air Heat Pumps With Hot Gas Reheat Utilizing the FX10 Controller

Address of your installer

Owner's Manual TABLE OF CONTENTS

HEALTHY CLIMATE Heat / Energy Recovery Ventilator

Product Data HRVCCLHU HRVCCSVC HRVCCLVU. Heat Recovery Ventilators FEATURES

INSTALLATION MANUAL MODELS ERV CONSTRUCTO 1.5 QUATTRO ERV CONSTRUCTO 2.0 QUATTRO READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY

SAT-3 Room Temperature Controller

ATC32U03 igate Communicating, Programmable Thermostat

Transcription:

WALL CONTROLS MAIN CONTROLS Due to the constant evolution of our technologies, it may be possible that some control functions are not compatible to some earlier unit models. For more details, please refer to the compatibility chart on last pages. All Venmar AVS wall controls are user-friendly. They were created for people who want to maximise the benefits of their residential ventilation unit. With Venmar AVS wall controls, the homeowner s specific needs are fulfilled. Operation Modes TURBO MODE Press the TURBO function key to turn the unit on air exchange in high speed during 4 hours, then, the unit will get back to its previous operation mode. Press the MODE key to choose the operation mode of the ventilation unit (except TURBO mode). Operating Mode will then appear on LCD screen (STANDBY, RECIRC, 20 min/h, CONT, SMART). VC0175 X-TOUCH Part no. 40455 5 manual modes: RECIRC, 20MIN/H, CONT, SMART and SMART ECO; Dehumidistat: When indoor humidity is too high and exceed the set point, unit will exchange air in high speed to take care of excess humidity. The humidity set point can be changed and you may refer to the Installation and Owner Guide; Three defrost cycling settings: Standard, Discretion which will defrost at the speed of operation either high or low, ans Plus, which will defrost in high speed for a longer period of time for very cold climate; Maintenance indicator; At installation, use the X-Touch main control to perform electronic balancing, without using balancing dampers. STANDBY Put the unit on stand-by mode, so it will only respond to override wall controls (if present). On LCD screen, only the House is visible showing the control is powered on. This is the factory set default mode. RECIRC Air is recirculated inside the house on high speed. 20 min/h The ventilation unit exchanges air intermittently on a one hour cycle as follows: OFF for 40 min. (or recirculation for 40 min. on low or high speed, see Settings) and then exchange air during 20 min. on low speed. Repeat cycle after the 20 min. of air exchange. CONT CONT Air is exchanged with the outdoors at the minimum blower speed. SMART Air exchange is managed according to indoor humidity measured by the wall control and outdoor temperature. In SMART mode, the SMART icon appears as well as the current operating mode called by SMART (For more details about SMART features, refer to the User Guide Main and Auxiliary wall controls available at www.venmar.ca).

MAIN CONTROLS (CONT D) VC0101 MODE PREF ALTITUDE Part no. 40445 Automatic and programmable control (keeps in memory all ventilation settings even after a power failure) Digital display with backlight (blue or green) Day, hour and periods of the day displayed Dynamic exchange and recirculation indicators, and also indoor and outdoors temperature Maintenance indicator SET SMART Operation Modes SMART Mode Our latest innovation! This mode optimizes automatically the ventilation functions to ensure reaching an unsurpassed comfort in the house. VENT Mode In this mode, the air exchange with the outside is performed with the speed (OFF, MIN or MAX) or with a 20, 30 or 40-minute per hour cycle, according to the user s choice. RECIRC Mode In this mode, the user decides to recirculate the air inside his house (OFF, MIN, MAX or OFF, MAX, according to the unit). PROG Mode The ventilation unit operation is factory set for alls 4 periods (morning, day, evening and night), for week days and week end days. However, these settings can be modified by the user to meet his own needs. Operation Modes RECIRC Mode* In this mode, the air is recirculated inside the house at high speed. VC0119 DECO-TOUCH Part no. 40400 Allows the user to choose either the manual modes or the automatic mode (dehumidistat) 1 x 1 LCD display Digital display with blue backlighting Dynamic exchange and recirculation* indicators Interior relative humidity displayed Maintenance indicator 20 min/h Mode The ventilation unit exchanges air intermittently on a one-hour cycle as follows: OFF for 40 min. (or recirculation* on high or low speed for 40 min.) and then exchanges air during 20 min. on low speed. Repeats cycle after the 20 min. of air exchange. Min Mode Air is exchanged with the outside on low speed. Max Mode Air is exchanged with the outside on high speed. * Recirculation is not available to all units. For more details, please refer to the compatibility chart on last pages. Hygrometer In the operating modes listed above, select a dehumidistat override so that if the relative humidity (RH) in the house exceeds the RH setting previously stored, the ventilation unit will exchange in high speed until the target indoor RH setting is reached.

MAIN CONTROLS (CONT D) S-T L-T MAX MIN RECIRCULATION MAX MIN INTERMITTENT VC0145 Simple-Touch Part no. 40390 VC0124 Lite-Touch Part no. 40370 The light indicator of this wall control shows clearly in wich operating mode the unit is. This push-button control has three functions: Recirculation (stops exchanging air with the outdoors and recirculates indoor air at high speed) Min (low speed air exchange) Max (high speed air exchange) NOTE: Wall control appearance may slightly vary. The light indicator of this wall control shows clearly in wich operating mode the unit is. This push-button control has three functions: Intermittent (unit is OFF during 40 minutes and then perform low speed air exchange with the outdoors during 20 minutes) Min (low speed air exchange) Max (high speed air exchange) NOTE: Wall control appearance may slightly vary. Z ON E 5 C 41 F OFF MIN MAX #XXXXX 01/98 C OM FOR T - -5 C 23 F -20 C -4 F CONSTRUCTO VC0086 Part no. 40350 The main control adjusts the air supply speed using the sliding button: OFF, MIN (low speed air exchange) and MAX (high speed air exchange). Also, the maximum humidity level for your house is selected by the knob.

AUXILIARY CONTROLS HOLD 60 OFF Turn Past 10 50 20 40 MINUTES 30 VC0009 Dehumidistat Part no. 11297 VC0017 60-minute mechanical timer Part no. 00910 The knob allows to adjust the maximum desired indoor humidity level during fall, winter and spring. This control is graduated in relative humidity percentage degrees. When a higher humidity level is detected, the unit turns on high speed until the situation is corrected. This timer allows for 10 to 60 minutes of high speed operation, to expel rapidly indoor stale air. Can be installed in bathrooms kitchen or laundry room. VC0141 20-minute lighted push button Part no. 12030 VC0143 20/40/60 minute push button Part no. 03364 This timer allows the unit to provide 20 minutes of high speed ventilation at the push of a button, to expel rapidly indoor stale air. Lighted when activated, up to five of them can be installed (e.g.: in bathroom, kitchen, laundry room, etc.). NOTE: Push button appearance may slightly vary. This timer allows the unit to turn on high speed during 20, 40 or 60 minutes to expel rapidly indoor stale air. Within 2 seconds, press once for 20 minutes, twice for 40 minutes or three times for a 60-minute activation. Press another time to deactivate. NOTE: Push button appearance may slightly vary.

WALL CONTROL COMPATIBILITY CHART The Dehumidistat, 60-minute crank timer and 20-minute push-button timer are compatible with all units. Model no. Name X-Touch Mod. no. 40455 Altitude version 3.01 Mod. no. 40440 Altitude version 4.04 and up Mod. no.40445 Deco-Touch version 2.01 Mod. no. 40395 Deco-Touch version 2.04 Mod. no. 40400 43911 AVS E15 ECM ERV PJ0514xxxxxxx (NOTE 2) PJ0514xxxxxxx (NOTE 2) 43901 AVS E15 ECM HRV PA0414xxxxxxx (NOTE 2) PA0414xxxxxxx (NOTE 2) 43135 AVS E15 HRV PC0114xxxxxxx (NOTE 2) PC0114xxxxxxx (NOTE 2) 41126 AVS E10 HRV PE0114xxxxxxx (NOTE 2) PE0114xxxxxxx (NOTE 2) X24ERVE, X24HRVE, X30ERVE & X30HRVE X24 ERV ECM, X24 HRV ECM, X30 ERV ECM & X30 HRV ECM 46121 & 47121 Novofit 1.5ES & Novofit 2.0ES 44162 & 44163 K7 ERV Qx0114xxxxxxx (NOTE 2) Qx0114xxxxxxx (NOTE 2) 44152 & 44153 K8 HRV Qx0114xxxxxxx (NOTE 2) Qx0114xxxxxxx (NOTE 2) 44500 & 44502 K10 HRV Qx0114xxxxxxx (NOTE 2) Qx0114xxxxxxx (NOTE 2) 44150 K7 HRV 46110 & 1601702 HRV 1.5ES NOTE 3 NOTE 3 47110 HRV 2.0ES NOTE 3 NOTE 3 47115 ERV 2.0ES NOTE 3 NOTE 3 46720 & 46725 Solo 1.5ES 47720 Solo 2.0ES 41502 & 41500 AVS 1.0 HRV 41506 & 41504 AVS 1.0 ERV Bx0814xxxxxxx (NOTE 2) Bx0814xxxxxxx (NOTE 2) Bx0814xxxxxxx (NOTE 2) Bx0814xxxxxxx (NOTE 2) 41554 & 41556 AVS C12 ERV 41550 & 41552 AVS C12 HRV 41702 AVS S10 ERVplus 41706 AVS S10n ERVplus 41700 AVS S10 ERV NOTE 3 NOTE 3 41704 AVS S10c ERV CR12HRV AVS CR12 HRV NOTE 3 NOTE 3 41708, 41709, 41718, 41719 X24ERVEN, X24HRVEN, X30ERVENn X30HRVEN S10 ERV ECM, S10 ERV ECM-R, S10d ERV ECM, S10d ERV ECM-R X24 ERV ECM-N, X24 HRV ECM-N, X30 ERV ECM-N & X30 HRV ECM-N NOTE 3 NOTE 3 NOTE 1: Wall control including configurable low speed recirculation in intermittent mode. NOTE 2: Low speed recirculation in intermittent mode starts with this unit serial number. However, this control remains compatible with units with serial number under this one. NOTE 3: Recirculation mode is not available for this unit.l. : The compatibility starts from that unit serial number. Letters and numbers Compatible Not compatible This code is the serial number of the ventilation unit; consider only the letters and numbers mentioned, not the xxx. E. g.: AVS E15 ECM ERV with serial number PJ05150004007 is fully compatible with Altitude version 4.03 and Deco-Touch version 2.04 (PJ0515 is higher than PJ0514). Subject to change without prior notice. Lite-Touch Simple- Touch 20/40/60 minutes Bx101702xxxxx () Bx101702xxxxx () Lx051702xxxxx () Lx021702xxxxx () TA0115xxxxxxx

WALL CONTROL COMPATIBILITY CHART (CONT D) The Dehumidistat, 60-minute crank timer and 20-minute push-button timer are compatible with all units. Model no. Name Altitude version 3.01 Mod. no. 40440 Altitude version 4.04 and up Mod. no. 40445 Deco-Touch version 2.01 Mod. no.40395 Deco-Touch version 2.04 Mod. no. 40400 43911 & 43910 AVS ERV EKO 1.5 NOTE 2 NOTE 2 43901 & 43900 AVS HRV EKO 1.5 NOTE 2 NOTE 2 43130 AVS 1.5V PC131211xxxxx NOTE 3 PC131211xxxxx NOTE 3 41121 AVS Novofit 1.0 NOTE 2 NOTE 2 43121 AVS Novofit 1.5 45121 AVS Novofit 2.0 43700, 43710, & 45700 AVS Duo 1.4, AVS Duo 1.2 & AVS Duo 1.9 44112, 44133 Kubix ERV NOTE 2 NOTE 2 44102, 44103 Kubix HRV Plus NOTE 2 NOTE 2 44150 Kubix HRV 43110 & 1601602 HRV 1.5 45110 & 1601612 HRV 2.0 43115 & 45115 ERV Quattro 1.5 & Quattro 2.0 43720 & 46725 Solo 1.5 45720 & 45725 Solo 2.0 41556 & 41554 AVS 1.2 ERV 43400, 45400 & 48400 1.3 HE, 1.8 HE & 2.6 HE 43300 3055 Compact 45300 4585 Compact 46700 & 47700 Duo 1.5 & Duo 2.0 H50100H & H50100E H50100H & H50100E Lx0114xxxxxxx Gx0314xxxxx () Lx0114xxxxxxx Gx0314xxxxx () Lite-Touch Simple-Touch 20/40/60 minutes NOTE 1: Wall control including configurable low speed recirculation in intermittent mode. NOTE 2: Compatible but low speed recirculation in intermittent mode is not available for this unit. NOTE 3: The compatibility starts from that unit serial number, but recirculation mode is not available for this unit. : Low speed recirculation in intermittent mode starts with this unit serial number. However, this control remains compatible with units with serial number under this one. Letters and numbers Compatible Not compatible This code is the serial number of the ventilation unit; consider only the letters and numbers mentioned, not the xxx. E. g.: AVS 1.2 ERV with serial number LC01152444567 is fully compatible with Altitude version 4.03 and Deco-Touch version 2.04 (LC0115 is higher than Lx0114). Subject to change without prior notice. Residential Products Group, 550 Lemire Blvd., Drummondville, Qc, Canada J2C 7W9 - Tel.: 1-800-567-3855 Fax: 1-800-567-1715 www.venmar.ca Controlsd170711