A wider lineup of DC Inverter and Non-Inverter air conditioners with 19 models is currently available. You can choose whichever that fits your

Similar documents
PCR0709A. Options. Indoor unit

Split Type Air Conditioners FTNE-M Series Cooling Only [50 Hz]

CHI NHAÙNH HAØ NOÄI Taàng 12, toøa nhaø Ocean Park Tower, 1 Ñaøo Duy Anh, Quaän Ñoáng Ña, Haø Noäi

Inverter Wall Mounted

Inverter Wall Mounted

The Comfort and Luxury You Deserve

Inverter Wall Mounted

PLXRMM1606B. Wall Mounted. FTN-A Series. COOLING ONLY [50Hz] V

The Comfort and Luxury You Deserve

Split Type Air Conditioners

Split Type Air Conditioners

The Comfort and Luxury You Deserve

LV Series. SEER 20+ Wall Mount Heat Pump

w w w. d a i k i n. e u ATXS-E

Daikin air conditioners for your home

KE Series. SEER 14+ Wall Mount Heat Pump or Cooling Only

for your home FTYN-GX FT(Y)N-F

Daikin air conditioners for your home

Inverter Wall Mounted Series

Daikin air conditioners for your home

Up to SEER 26.1 Wall Mount Heat Pump

PCRAU0726F. Multi-Split Type Air Conditioners L Series with DC Inverter Power Control Cooling Only & Heat Pump [50 Hz]

Ceiling Mounted Cassette ( Round Flow with Sensing ) Type

BENEFIT FROM LOWER FUEL COSTS.

DAIKIN Modular Inverter Air Cooled Chiller

The Comfort and Luxury You D eserve

Si REMOVAL PROCEDURE. 2.5/3.2/3.5 kw Class. Outdoor Unit Inverter Pair Type

FAQ. Wall Mount Heat Pump or Cooling Only

SiBE04-808_C. Service Manual. Inverter Pair Wall Mounted Type G-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

Service Manual. Inverter Pair Floor Standing Type K-Series. Draft. SiBE [Applied Models] Inverter Pair : Heat Pump

SiBE041010EA. Service Manual. Inverter Pair Wall Mounted Type J-Series. [Applied Models] Inverter Pair : Heat Pump

Service Manual. Inverter Pair Floor / Ceiling Suspended Dual Type BA-Series. SiBE05-722_C

MULTI SYSTEM TECHNOLOGY. 1. Ururu Humidification PART 2 - URURU MULTI

PCXSPH1732A. Warning. Head office: Umeda Center Bldg., , Nakazaki-Nishi, Kita-ku, Osaka, Japan.

LV Series. SEER 15+ Concealed Built in Heat Pump

for your home FTXS-G WALL MOUNTED UNIT

Si REMOVAL PROCEDURE. 4.0/5.0/5.2/5.8/6.8/7.5 kw Class. Outdoor Unit Inverter Multi Type

Full range. A class energy label. for your home WALL MOUNTED UNIT. air to air heat pumps. FTXS-G

SPLIT SYSTEM HEATING AND COOLING SOLUTIONS FROM DAIKIN. Energy efficient heating and cooling solutions for your home

Lineup of DC Inverter Air Conditioners with R-32 Refrigerant

FBQ. DC Duct Heat Pump or Cooling Only

PCRAU0306K. Happiness starts at home.

The World s No.1 Heat Pump Company HEATING AND COOLING SOLUTIONS SUPER MULTI NX MULTI-SPLIT AIR CONDITIONERS DC INVERTER CONTROL

HEAT PUMPS BY DAIKIN. Energy efficient heating and cooling solutions for your home

SiUS091601E Inverter Pair Wall Mounted Type FTX-N Series Floor Standing Type FVXS-N Series [Applied Models] Inverter Pair : Heat Pump

Air Conditioning Product Brochure 2015/2016. Classic Series Hi-Wall Split Systems. Everyday Cool

AIR PURIFICATION SOLUTIONS PCAPNZ1017 AIR PURIFIER

FOR REPLACEMENT USE PCV1213. Cooling Only 50 Hz

Warning. Specifications, designs and other content appearing in this brochure are current as of May 2013 but subject to change without notice.

Technical Guide. Multizone: Multi-Split Type Heat Pump Systems

technical data air conditioning systems FT(Y)S-B Wall Mounted Unit Split Sky Air

DAIKIN FAQ SERIES HEATING & COOLING SYSTEMS. INDOOR WALL-MOUNTED UNITS Up to 18.6 SEER / Up to 9.4 HSPF Up to 12.7 EER

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE.

SPLIT SYSTEM HEATING AND COOLING SOLUTIONS FROM DAIKIN. Energy efficient heating and cooling solutions for your home

Non Inverter Wall Mounted Series

Air Conditioners. Technical Data FTXS-G

Inverter Y Series.

SPLIT SYSTEM HEATING AND COOLING SOLUTIONS FROM DAIKIN. Energy efficient heating and cooling solutions for your home

SiUS181631EA. Service Manual. Multi-Split Type Air Conditioners RMXS-L Series. [Applied Models] Inverter Multi : Heat Pump

FTXS20G FTXS25G FTXS35G FTXS42G FTXS50G FTXS60G FTXS71G

PLXSID1605. Warning HEAD OFFICE :

SPLIT SYSTEM HEATING AND COOLING SOLUTIONS FROM DAIKIN. Energy efficient heating and cooling solutions for your home

DAIKIN FCQ SERIES HEATING & COOLING SYSTEMS. ROUNDFLOW CEILING-MOUNTED CASSETTE Up to 18.6 SEER / Up to 10.2 HSPF Up to 13.0 EER

Product Brochure 2017

DAIKIN 17 SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEM S. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY

for your home FLXS-B Flexi type unit air to air heat pumps

SKYAIR SERIES SINGLE ZONE HEATING & COOLING SYSTEMS. Up to 20 SEER / Up to 12.0 HSPF / 14.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR

Consumer Guide. Split System: Wall Mounted Inverter Heat Pumps

DSS SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEMS. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY

-20 C 11 HSPF 23 SEER WALL-MOUNTED HEAT PUMPS. 10 years* *See details on the back SINGLE ZONE MULTI-ZONE (UP TO 5 ZONES) descair.

About Daikin: WARNINGS:

AIR CONDITIONERS, HEATING & COOLING for your home

FTQ SERIES DUCTED HEAT PUMP SYSTEMS. INDOOR AND OUTDOOR UNITS Up to 20 SEER / Up to 12 HSPF / Up to 14.5 EER INVERTER, VARIABLE SPEED COMPRESSOR

EEDEN technical data. air conditioning systems FTXS-G2V1B. Indoor units. Split - Sky Air

NEW DAIKIN FTQ SERIES HEATING AND COOLING SYSTEMS. MULTI-POSITIONAL AIR HANDLER Up to 16 SEER / Up to 10.4 HSPF / Up to 12.5 EER

SiBE041525F. Service Manual. Inverter Pair Wall Mounted Type FTX/ATX-K Series. [Applicable Models] Inverter Pair: Heat Pump

VRV+AHU System DAIKIN NEW STANDARD SERIES UNIT MODEL AHUR-CA/SA

SiUS04-924_A. Service Manual. Inverter Pair Wall Mounted Type H-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

DAIKIN FHQ SERIES HEAT PUMP & COOLING ONLY SYSTEMS. CEILING-SUSPENDED CASSETTE Up to 18.0 SEER / Up to 10.0 HSPF Up to 14.0 EER

Service Manual. Inverter Pair. Floor / Ceiling Suspended Dual Type B-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

RC-0219-A. Single-Split Non Inverter Series

DAIKIN FBQ DUCTED SERIES HEATING & COOLING SYSTEMS. DC DUCT-CONCEALED Up to 17.5 SEER / Up to 10.6 HSPF Up to 13.0 EER

DAIKIN FHQ SERIES HEAT PUMP & COOLING ONLY SYSTEMS. CEILING-SUSPENDED CASSETTE Up to 18.0 SEER / Up to 10.0 HSPF Up to 14.0 EER

AIR CONDITIONERS LINE-UP

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

we care about Better Air

AIR CONDITIONING REVERSE-CYCLE INVERTER

Inverter console UFV system. Compact design and personalised air flow selection

HEAT PUMPS BY DAIKIN. Energy efficient heating and cooling solutions for your home

AIR CONDITIONING AGAIN, AGAIN & AGAIN ONLY PANASONIC GETS 5 STARS #AIRTHATMOVESYOU

Air conditioners, heating & cooling for shops,restaurants and offices

PRODUCT CATALOGUE. For Qatar AIR CONDITIONERS LINE-UP SPLIT / WINDOW

. Creating Maximum Comfort

Split System Air Conditioning

M-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

COOLING ONLY HEAT PUMP PCV0612F. Cooling Only 50 Hz/60 Hz. Heat Pump 50 Hz/60 Hz

Including mounting plate. General Rating Nameplate. Terminal strip with earth terminal

technical data air conditioning systems FTKS/FTXS-C FTKS/FTXS-B Wall Mounted, Inverter Controlled Unit Split Sky Air

DESIGNER RANGE SLEEK, SLIMLINE DESIGN HIGH ENERGY EFFICIENCY BACKED BY A 5 YEAR FULL PARTS & LABOUR WARRANTY

Hi-spec Design model. Photo : LT series

Transcription:

PCRMY1204

A wider lineup of DC Inverter and Non-Inverter air conditioners with 19 models is currently available. You can choose whichever that fits your lifestyle. Both series of Daikin air conditioners help to make life more comfortable with their low sound levels and simple, stylish designs. The choice is yours. Enjoy a comfortable life with Daikin technology. 1

Contents 3 Product Line Up FTKS series FTKS25/35D FTKS50G/60G FTKS71H FTKD series FTKD25/35/42/50/60/71G FT series FT25/35/50/60H FTE series FTE25/35/50/60K 5 Inverter Technology 7 Special Functions for DC Inverter Air Conditioners Intelligent Eye / Econo Mode Quiet Operation Quiet Operation 9 Airflow Power-Airflow Dual Flaps / Wide-Angle Louvres Vertical Auto-Swing / Horizontal Auto Swing 3-D Airflow / Comfort Airflow Mode Inverter Powerful Operation / New Powerful Operation Indoor Unit On/Off Switch / Night Set Mode Home Leave operation 11 Cleanliness Titanium Apatite Photocatalytic Air-Purifying Filter Air-Purifying Filter with Photocatalytic Deodorising Function Mould Proof Operation / Wipe-Clean Flat Panel 13 Fundamental Features High Energy Savings / Quiet Sound Levels Anticorrosion Treatment of Outdoor Heat Exchanger Fins Installation Flexibility 15 Function Dictionary 17 Function List 19 Specifications 22 Options 2

FTKS series FTKS25/35D RKS25/35G RKS50/60G FTKS50/60G FTKS25DVM / RKS25GVMG 2.5 (1.2-3.2) 8,500 (4,050-10,900) FTKS35DVM / RKS35GVMG 3.5 (1.4-4.0) 11,900 (4,750-13,650) FTKS50GVMG / RKS50GVMG 5.0 (1.7-6.0) 17,100 (5,800-20,500) FTKS60GVMG / RKS60GVMG 6.0 (2.3-6.7) 20,500 (7,800-22,900) FTKS71HVMG / RKS71HVMG 7.1 (2.3-8.5) 24,200 (7,800-29,000) RKS71H FTKS71H FTKD series FTKD25/35G RKD25/35G FTKD42/50/60/71G RKD42G RKD50/60/71G 3 FTKD25GVM / RKD25GVM 2.5 (1.2-3.2) 8,500 (4,050-10,900) FTKD35GVM / RKD35GVM 3.2 (1.4-4.0) 10,900 (4,750-13,650) FTKD42GVM / RKD42GVM 4.2 (2.0-5.0) 14,300 (6,800-17,100) FTKD50GVM / RKD50GVM 5.2 (1.5-5.9) 17,700 (5,100-20,100) FTKD60GVM / RKD60GVM 6.2 (1.5-6.5) 21,200 (5,100-22,200) FTKD71GVM / RKD71GVM 7.1 (2.1-7.6) 24,200 (7,200-25,900)

FT series FT25/35H R25H R35H FT25HV1 / R25HV1 2.60 8,900 FT35HV1 / R35HV1 3.60 12,300 FT50/60H R50H R60H FT50HV1 / R50HV1 5.20 17,750 FT60HV1 / R60HV1 6.60 22,530 FTE series FTE25KV1 / RE25KV1 2.60 8,900 FTE25/35K RE25/35K FTE35KV1 / RE35KV1 3.35 11,450 FTE50KV1 / RE50KV1 5.20 17,750 FTE50/60K RE50K RE60K FTE60KV1 / RE60KV1 6.40 21,800 MODEL NAME 25 35 CAPACITY INDEX 42 50 60 71 FTKS series FTKS FTKD series FTKD FT series NON INVERTER FTE series NON INVERTER FT FTE 4

Inverter Advantages Compared to Non-Inverter Features of Inverter Technology An inverter is a device for converting frequency. The technology is used in many home appliances and controls the electric voltage, current and frequency. Inverter air conditioners can vary their cooling capacity by adjusting the power supply frequency of their compressors. In contrast, non-inverter air conditioners have a fixed cooling capacity and can only control the indoor temperature by starting or stopping their compressors. As a result, inverter air conditioners are more energy-saving and comfortable than non-inverter air conditioners. Powerful Inverter air conditioners operate at maximum capacity as soon as they start up. As a result, the set temperature can be reached more quickly. Variable Operation Inverter Power Control Power source Raise frequency Lower frequency Non-inverter type air conditioner Compressor High-speed rotation Low-speed rotation Compressor High capacity Low capacity Energy Saving After the indoor temperature approaches the set temperature, Inverter Control adjusts to low capacity operation to maintain this temperature. This makes inverter models more energy-saving than non-inverter models, which must repeatedly start or stop their compressors to maintain the room temperature. Power source Constant speed rotation Fixed capacity Inverter air conditioners are able to vary their operating capacity. Non-inverter air conditioners can only operate at a fixed capacity. Comfortable Temperature Control Temp. Compressor off Not cool Comfortable Inverter air conditioners finely adjust capacity according to changes in the air-conditioning load and the difference between the indoor temperature and set temperature is small. These give higher comfort levels than with noninverter air conditioners. Set temp. Cools a room in less time Too cool Starts Small temp. difference Compressor off During cooling operation Non-inverter type Inverter type Time This diagram is a representation for illustrative purpose only. 5

Energy-Saving Technological Features Swing Compressor Swing compressor Reluctance DC motor Thanks to its smooth rotation, the swing compressor decreases friction and vibration. It also prevents the leakage of refrigerant gas during compression. These advantages provide quiet and efficient operation. Swing bush Integral piston of blade and roller Refrigerant gas The swing compressor can reduce operational vibration and sound because its piston moves smoothly inside the compressor. Reluctance DC Motor for Compressor Neodymium magnets are used in the pink-coloured area. Daikin DC Inverter models are equipped with the Reluctance DC motor for compressor. The Reluctance DC motor uses 2 different types of torque, neodymium magnet* 1 and reluctance torque* 2. This motor can save energy because it generates more power with a smaller electric power than an AC or conventional DC motor. It is more efficient at the low frequencies most coonly used by air conditioners,* 3 improving efficiency by approximately 20%. *1. A neodymium magnet is approximately 10 times stronger than a standard ferrite magnet. *2. The torque created by the change in power between the iron and magnet parts. *3. The frequency range used by air conditioners during periods of stable operation. This is the range in which air conditioners operate for the longest periods. Efficiency of Reluctance DC motor *4 Motor efficiency (%) 90 80 70 60 Reluctance DC motor Conventional DC motor More than 20% AC motor 50 0 30 60 90 120 Rotational speed (rps) Small load Large load Low capacity High capacity *4. Data are based on studies conducted under controlled conditions at a Daikin laboratory. DC Motor for Fan The DC motor allows fine rotation control, which reduces energy consumption. The motor also provides improvements in operational efficiency of up to 40%, compared to an AC motor. These improvements are particularly noticeable in the low-speed range. Efficiency (%) Efficiency of DC motor for fan * 5 (comparison with a conventional AC motor) 100 80 60 40 20 0 Approx. 40% increase DC motor AC motor Approx. 20% increase 200 300 400 500 600 700 800 900 1000 Motor speed (rpm) *5. Data are based on studies conducted under controlled conditions at a Daikin laboratory. PAM Control PAM (Pulse Amplitude Modulation) control reduces energy loss by controlling how often the converter switches on and off. What Is DC Inverter? Daikin calls an inverter model that is equipped with a DC motor DC Inverter. A DC motor offers higher efficiency than an AC motor. A DC motor uses the power of magnets to attract and repel to generate rotation. A DC motor that is equipped with high-power neodymium magnets, which enable even greater efficiency, is called a Reluctance DC motor. 6

Intelligent Eye Intelligent Eye prevents energy wastage by using its infrared sensor to detect human movement in a room. When there is no movement, Intelligent Eye increases the temperature by 2 C to give energy savings. This reduces energy wastage if, for example, you forget to turn off the air conditioner. This function can be conveniently activated from the remote controller. This function is available for FTKS25/35D, 50/60G, 71H and FTKD25/35/ 42/50/60/71G. Once Intelligent Eye is set, it continues to work to save energy. You do not need to push the SENSOR button each time you wish to use this function. The Intelligent Eye indicator lights when movement is detected. Intelligent Eye sensor Top view 7 m Side view 7 m 110 When you are in the room, the air conditioner maintains the set temperature. If Intelligent Eye detects no human movement for 20 minutes, it automatically adjusts the set temperature by 2 C. When you enter the room, Intelligent Eye automatically returns the temperature to the set level. Econo Mode button Intelligent Eye button Econo Mode This function limits both the maximum running current and maximum power consumption to 70%* of those during normal operation. It is particularly effective if the cooling load is high, for example, at start-up or during large gatherings and periods of direct sunshine. At the same time, it maintains maximum capacity at 80%* of normal, giving improved operating efficiency, although it may take slightly longer to reach the set temperature. Econo Mode is also useful for preventing circuit breakers from being overloaded during temporary peaks in the running current. The function is easily activated from the remote controller by pushing the ECONO button. This function is available for FTKS25/35D, 71H and FTKD25/35/42/50/60/71G. *Econo Mode limits FTKS71H s maximum power consumption to 50% during normal operation and also maintains maximum capacity at 60%. FTKS25/35D and FTKD25/35/42/50/60/71G Running current and power consumption 100% 70% Econo Mode Normal operation Maximum during normal operation Maximum during Econo Mode From start-up until set temperature is reached Time This diagram is a representation for illustrative purposes only. Maximum capacity decreases during Econo Mode, requiring more time to reach the set temperature. 7

This series gives you the choice of 5-step, Quiet or Automatic settings for the fan speed. The Quiet setting selects Indoor Unit Quiet Operation. This function decreases the operation sound level by 3 db (A) below the Low setting. This wide range of settings allows you to precisely control the fan speed according to your requirements. For example, Indoor Unit Quiet Operation provides you with a good night s sleep. The sound level for FTKS25D is 22 db (A). This function is available for FTKS25/35D, 50/60G, 71H and FTKD25/35/ 42/50/60/71G. FTKS25D Fan speeds Indoor Unit Quiet Operation Sound levels High (H) Low (L) Quiet (SL) 37 db (A) 25 db (A) 22 db (A) 3 db(a) Fan speed Auto Low SL L M H High Sound level Each decrease in airflow volume reduces the sound level. Indoor Unit Quiet Operation icon Selects fan speed and Indoor Unit Quiet Operation Outdoor Unit Quiet Operation Outdoor Unit Quiet Operation 22 db (A) Is So Quiet You Can Even Hear Whispers This function decreases the operation sound level by 3 to 5 db (A) below the rated operation. It provides a low sound level of 44 db (A) for RKD42/50G. This function is available for FTKS25/35D, 50/60G, 71H and FTKD25/35/ 42/50/60/71G. may decrease when Outdoor Unit Quiet Operation is selected. RKD42/50G Operations Sound levels 20 22 30 40 44 50 Rustling of leaves Library (db (A)) Rated (H) Quiet (L) 49 db (A) 44 db (A) 5 db (A) Pendulum of a wall clock Normal office Based on Examples of Sound Levels, Ministry of the Environment, Japan, November 12, 2002 8

Power-Airflow Dual Flaps Wide-Angle Louvres Power-Airflow Dual Flaps and Wide-Angle Louvres work in tandem to precisely control both vertical and horizontal airflow for distribution of air. Power-Airflow Dual Flaps Vertical Auto-Swing (up and down) Horizontal Auto-Swing (left and right) 3-D Airflow Vertical Auto-Swing automatically moves the flaps up and down and Horizontal Auto-Swing automatically moves the louvres to the left and right. 3-D Airflow combines Vertical and Horizontal Auto-Swing to circulate air to every part of a room for uniform cooling of even large spaces. Horizontal Auto-Swing and 3-D Airflow are available for FTKS50/60G, 71H and FTKD25/35/42/50/60/71G. : the flaps flatten out during operation so that cool air slides off to reach the corner of the room. Wide-Angle Louvres From a corner to the centre The louvres can be adjusted by hand for FTKS25/35D, FTKD25/35G, FT25/35/50/ 60H and FTE25/35/50/60K and with the wireless remote controller for FTKS50/60G, 71H and FTKD42/50/60/71G. Comfort Airflow Mode Covers even a spacious room Comfort Airflow Mode prevents uncomfortable drafts from blowing directly on to your body. With this function, when you press the COMFORT button, the flap moves upward to prevent direct cold drafts. This function is available for FTKS71H and FTKD42/50/60/71G. 9

Inverter Powerful Operation Inverter Powerful Operation boosts cooling performance for a 20-minute period. This is convenient both when you first turn on your air conditioner and when you want to quickly change the temperature during operation. This function is available for FTKS25/35D, 50/60G, 71H and FTKD25/35/42/50/60/71G. Home Leave Operation Home Leave Operation prevents large rises in the indoor temperature by continuing operation* while you are sleeping or out of your home. This means that an air-conditioned welcome awaits when you wake or return. It also means that the indoor temperature can quickly return to your favourite comfort setting. This function is available for FTKS50/60G. * Home Leave Operation can be set at any temperature from 18 to 32 C. During operation, 23 C for the room temperature setting, and 28 C for the Home Leave setting. 23 C New Powerful Operation New Powerful Operation boosts airflow to maximum volume for a 20-minute period. After this, the unit automatically returns to its previous settings. This function is activated by pushing the POWERFUL button on the remote controller. So, for example, now when you come home on a hot day, a powerful airflow will always be right at your fingertips. This function is available for FT25/35/50/60H and FTE50/60K 28 C One push!! Start Home Leave Operation simply by pushing its button on the remote controller. Indoor Unit On/Off Switch The unit can be conveniently started manually in the event the wireless remote controller is misplaced or the wireless remote controller batteries are not charged. Night Set Mode Indoor Unit On/Off Switch 23 C When you are out of your home, your air conditioner prevents large rises in the indoor temperature by continuing to operate using Home Leave Operation settings. Pressing the Off timer button automatically selects Night Set Mode. Room temperature is raised by 0.5 C after 60 minutes to prevent excessive cooling for your pleasant sleep. +0.5 C Set temp. before Off timer begins to operate Push again!! When you return, you will be greeted by an airconditioned room. Just push the HOME LEAVE button again to return to your previous settings. Time 60 min. Unit: minutes Off timer turns on Off timer stops air conditioner operation: Room temperature is raised by 0.5 C after 60 minutes. 10

Titanium Apatite Photocatalytic Air-Purifying Filter Titanium apatite is a new photocatalytic material with advanced adsorption power. While the filter s micron-level fibres trap dust, this photocatalyst effectively adsorbs and decomposes bacteria. The photocatalyst is activated simply by exposure to light. The filter delivers consistent performance for approximately 3 years if washing with water is performed once in 6 months. Air filter Catches dust Titanium Apatite Photocatalytic Air-Purifying Filter Bacteria removal test Testing method: Dropping method Testing organisation: Japan Spinners Inspecting Foundation Result certificate: No. 012553-1 and 012553-2 This filter is not a medical device. Benefits such as the adsorption and decomposition of bacteria are only effective for substances that are collected on and in direct contact with the Titanium Apatite Photocatalytic Air-Purifying Filter. Effect of Titanium Apatite Photocatalyst Adsorbs Removes Light Odours Decomposed Bacteria Deactivated Titanium Apatite Photocatalyst Photocatalyst Mechanism The Titanium Apatite Photocatalytic Air-Purifying Filter incorporates titanium apatite. Titanium apatite is a photocatalyst material with advanced adsorption power. When this photocatalyst is exposed to light, a powerful oxidising action occurs. Light Odours Apatite adsorbs bacteria. At the same time, the photocatalyst oxidises odour components, breaking them down. Photocatalyst Active particles Odours Light strikes the photocatalyst and activates the surface particles. A chemical reaction decomposes the odours into CO2, O3 and H2. The odourless substances are released into the air. 11

Mould-Proof Operation When cooling or dry operation is stopped, fan-only operation runs automatically for 1 hour. This airflow dries the inside of the indoor unit to reduce the generation of mould and odours. This function is available for FTKS25/35D and FTKD25/35G. Easy to Coordinate Daikin has always focused on creating sleek, modern air conditioners that coordinate smoothly with any type of interior decor. This concept has taken a major step forward with the versatile grilleless flat panel design. Wipe-Clean Flat Panel Conventional Front Grille Design Flat panel models can be cleaned instantly with a single wipe of a cloth across their smooth surface. If more thorough cleaning is required, the panel can also be easily removed from the unit. Dust 1. Difficult to remove dust on the grille through wiping alone 2. Reduced capacity due to increased suction resistance Front grille design units collect dust on their air inlet grilles unless these grilles are cleaned regularly. 3. High sound levels due to increased suction resistance 12

High Energy Savings The FTKD25G provides high COP of 3.65. This model is appropriate for rooms, which are air-conditioned for long periods. COP FTKS25D 3.57 FTKS35D 3.38 FTKS50G 3.57 FTKS60G 3.37 FTKS71H 3.38 What Is COP? An air conditioner s COP (Coefficient of Performance) indicates how efficiently the unit uses energy. A higher COP means greater energy efficiency. It also means lower electricity consumption, so you save money. COP = (W) Power consumption (W) COP COP FTKD25G 3.65 FT25H 3.28 FTKD35G 3.60 FT35H 3.28 FTKD42G 3.60 FTKD50G 3.30 FT50H 3.28 FTKD60G 3.10 FT60H 3.28 FTKD71G 2.85 FTE25K FTE35K FTE50K FTE60K COP 3.20 3.00 3.00 3.00 Quiet Sound Levels A quiet indoor unit is essential for your personal comfort, and a quiet outdoor unit is just as important for peace in your neighbourhood. FTKS25D offers a low sound level of 25 db (A) for indoor unit operation and 46 db (A) for outdoor unit operation. Sound levels (L) Sound levels (L) FTKS25D 25 RKS25G 43 FTKD25G FTKS35D 26 RKS35G 44 FTKD35G FTKD42G FTKS50G 34 RKS50G 44 FTKD50G FTKS60G 37 RKS60G 49 FTKD60G Unit: db (A) FTKS71H 37 RKS71H 49 FTKD71G 25 db (A) is So Quiet You Can Even Hear Whispers Sound levels (L) 28 29 36 35 36 37 Sound levels (L) RKD25G 43 RKD35G 44 RKD42G 44 RKD50G 44 RKD60G 46 RKD71G 49 20 25 30 40 46 50 (db(a)) FT25H FT35H FT50H FT60H Rustling of leaves Library Pendulum of a wall clock Normal office Sound levels (L) 28 31 35 36 Based on Examples of Sound Levels, Ministry of the Environment, Japan, November 12, 2002 R25H R35H R50H R60H Sound levels (L) 49 49 52 54 FTE25K FTE35K FTE50K FTE60K Sound levels (L) 28 33 35 36 RE25K RE35K RE50K RE60K Sound levels (L) 49 50 53 55 Based on 230 V power supply 13

Anticorrosion Treatment of Outdoor Heat Exchanger Fins The outdoor unit s heat exchanger fins are processed using a special anticorrosion treatment. The surface is covered with a thin acrylic resin layer to enhance the fins resistance to acid rain and salt corrosion. A hydrophilic film layer also prevents rust caused by the run off of water droplets. Cross section of anticorrosion-treated fin Hydrophilic film Aluminium Corrosion-resistant acrylic resin Heat exchanger fin Installation Flexibility A long piping length gives installation flexibility. Installation is possible even if there is no space for the outdoor unit near the indoor unit. FTKS25D FTKS35D FTKS50G FTKS60G FTKS71H FTKD25G FTKD35G FTKD42G FTKD50G FTKD60G FTKD71G Max. piping length 25 m 30 m Max. piping length 25 m 30 m Max. height difference 15 m 20 m Max. height difference 15 m 20 m FT25HV1 FT35HV1 FT50HV1 FT60HV1 FTE25KV1 FTE35KV1 FTE50KV1 FTE60KV1 Max. piping length 25 m 30 m 20 m Max. height difference 15 m 14

Function Dictionary Comfortable Airflow Comfort Control Power-Airflow Dual Flaps Power-Airflow Dual Flaps can flatten out during cooling operation to deliver cool air to the corners of a room. See page 9 Wide-Angle Louvres The smoothly curved Wide-Angle Louvres provide wide airflow coverage for effective operation no matter where the indoor unit is placed in a room. See page 9 Vertical Auto-Swing (up and down) This function automatically moves the flaps up and down to distribute air across a room. See page 9 Horizontal Auto-Swing (left and right) Horizontal Auto-Swing automatically moves the louvres to the left and right to cover a room with cool air. See page 9 3-D Airflow This function combines Vertical and Horizontal Auto- Swing to circulate a cloud of cool air right to the corners of even large spaces. See page 9 Comfort Airflow Mode This function prevents uncomfortable drafts from blowing directly on to the body. The flap changes the airflow direction. To prevent drafts, the flap moves upward during operation. See page 9 Indoor Unit Quiet Operation operating sound levels are decreased by 3 db (A) from the Low setting fan speed using the wireless remote controller. See page 8 Outdoor Unit Quiet Operation operating sound levels are decreased by 3 to 5 db (A) from the rated operation sound using the wireless remote controller. See page 8 Intelligent Eye Intelligent Eye with its infrared sensor automatically controls air conditioner operation according to human movement in a room. When there is no movement, it adjusts the temperature by 2 C for energy savings. See page 7 Prograe Dry Function This function automatically reduces the level of humidity. Auto Fan Speed The microprocessor automatically controls fan speed to adjust the room temperature to the set temperature. Lifestyle Convenience Econo Mode This mode limits maximum running current to 70% and power consumption to 50% to 70% of normal operation, while maintaining maximum capacity at 60% to 80%. This improves operating efficiency and also prevents circuit breakers from being overloaded. See page 7 Inverter Powerful Operation This function is convenient for boosting cooling performance for a 20-minute period both when you first turn on your air conditioner or want to quickly change the room temperature. See page 10 New Powerful Operation New Powerful Operation boosts airflow to maximum volume for a 20-minute period. After this, the unit automatically returns to its previous settings. See page 10 Home Leave Operation Home Leave Operation continues operation to prevent a room from becoming too hot, while you are sleeping or out of your home. Select any temperature from 18 to 32 C. See page 10 Indoor Unit On/Off Switch The unit can be conveniently started manually in the event the wireless remote controller is misplaced or the wireless remote controller batteries are not charged. See page 10 15

Cleanliness Worry Free Titanium Apatite Photocatalytic Air-Purifying Filter This filter contains the new photocatalytic material titanium apatite. While the filter s micron-level fibres trap dust, this photocatalyst adsorbs and decomposes bacteria. The filter can be used for up to 3 years with proper maintenance. See page 11 Mould-Proof Operation Mould-Proof Operation automatically runs fan-only operation for 1 hour when cooling or dry operation is stopped. This airflow prevents the generation of mould and mould odours inside the indoor unit. See page 12 Wipe-Clean Flat Panel The flat panel models can be cleaned with only the single pass of a cloth across their smooth surface. The flat panel can also be easily removed for more thorough cleaning. See page 12 Auto-Restart after Power Failure The air conditioner memorises the settings for mode, airflow, temperature, etc., and automatically returns to them when power is restored after a power failure. Self-Diagnosis with Digital Display Malfunction codes are shown on the digital display panel of the wireless remote controller for fast and easy maintenance. Anticorrosion Treatment of Outdoor Heat Exchanger Fins The outdoor unit s heat exchanger fins are processed using a special anticorrosion treatment. The surface is covered with a thin acrylic resin layer to enhance the fins resistance to acid rain and salt corrosion. See page 14 Timers 24-Hour On/Off Timer This timer can be preset to start and stop at any time within a 24-hour period. The air conditioner is started/ stopped simply by pressing the On/Off timer button on the wireless remote controller. Night Set Mode Pressing the Off timer button automatically selects Night Set Mode. This function prevents excessive cooling for your pleasant sleep. Room temperature is raised by 0.5 C after 60 minutes for cooling operation. See page 10 16

Function List Indoor Unit s FTKS series Functions FTKS 25/35D FTKS 50/60G FTKS 71H DC Inverter Power-Airflow Dual Flaps Comfortable Airflow Wide-Angle Louvers Vertical Auto-Swing (up and down) Horizontal Auto-Swing (left and right) 3-D Airflow Comfort Airflow Mode Comfort Control Indoor Unit Quiet Operation Intelligent Eye Prograe Dry Function Auto Fan Speed Econo Mode Lifestyle Convenience Inverter Powerful Operation New Powerful Operation Home Leave Operation Indoor Unit On/Off Switch Cleanliness Titanium Apatite Photocatalytic Air-Purifying Filter Mould-Proof Operation Wipe-Clean Flat Panel Timers 24-Hour On/Off Timer Night Set Mode Worry Free Auto-Restart after Power Failure Self-Diagnosis with Digital Display Outdoor Unit Functions s RKS 25/35G RKS 50/60G RKS 71H Worry Comfort Free Comfort Control Outdoor Unit Quiet Operation Anticorrosion Treatment of Outdoor Heat Exchanger Fins 17

FTKD series FT series FTE series FTKD 25/35G FTKD 42/50/60/71G FT 25/35H FT 50/60H FTE 25/35K FTE 50/60K RKD 25/35G RKD 42/50/60/71G R 25/35H R 50/60H RE 25/35K RE 50/60K 18

Specifications FTKS25/35D name Rated (Min.-Max.) Power supply Running current Rated Power consumption Rated (Min.-Max.) COP Rated Front panel colour Airflow rate (H) Fan speed Sound levels (H/L/SL) Dimensions (H x W x D) Machine weight Casing colour Type Compressor Motor output Refrigerant charge (R-410A) Sound levels (H/L) Dimensions (H x W x D) Machine weight Operation range Piping connections Max. piping length Max. height difference FTKS series FTKS50/60G and 71H name Power supply Running current Power consumption COP Front panel colour Airflow rate (H) Fan speed Sound levels (H/L/SL) Dimensions (H x W x D) Machine weight Casing colour Piping connections Max. piping length Max. height difference FTKS series Liquid Gas Drain Rated (Min.-Max.) Rated Rated (Min.-Max.) Rated Type Compressor Motor output Refrigerant charge (R-410A) Sound levels (H/L) Dimensions (H x W x D) Machine weight Operation range Liquid Gas Drain A W W/W m 3 /min (cfm) db (A) W db (A) CDB m A W W/W m 3 /min (cfm) db (A) W db (A) CDB m FTKS25DVM RKS25GVMG 2.5 (1.2-3.2) 8,500 (4,050-10,900) 3.9 700 (295-1,050) 3.57 FTKS25DVM 8.7 (307) 37/25/22 RKS25GVMG 0.8 46/43 32 FTKS50GVMG RKS50GVMG 5.0 (1.7-6.0) 17,100 (5,800-20,500) 6.2 1,400 (440-2,080) 3.57 FTKS50GVMG 14.7 (519) FTKS60GVMG RKS60GVMG 6.0 (2.3-6.7) 20,500 (7,800-22,900) 1 phase, 220-240 V / 220-230 V, 50/60 Hz 7.8 1,780 (570-3,580) 3.37 FTKS60GVMG White 17.4 (614) 5 steps, quiet and automatic 43/34/31 46/37/34 290 x 1,050 x 238 12 RKS50GVMG RKS60GVMG Ivory white Hermetically sealed swing type 1,100 1,920 1.5 1.7 47/44 54/49 47 12.7 1 phase, 220-240 V / 220-230 V, 50/60 Hz 735 x 825 x 300 6.4 White 5 steps, quiet and automatic 283 x 800 x 195 9 Ivory white Hermetically sealed swing type 600 550 x 765 x 285 10 to 46 6.4 9.5 18.0 25 15 55 10 to 46 18.0 30 20 FTKS35DVM RKS35GVMG 3.5 (1.4-4.0) 11,900 (4,750-13,650) 4.8 1,035 (300-1,400) 3.38 FTKS35DVM 15.9 8.9 (314) 39/26/23 RKS35GVMG 1.0 47/44 34 FTKS71HVMG RKS71HVMG 7.1 (2.3-8.5) 24,200 (7,800-29,000) 9.2 2,100 (570-3,100) 3.38 FTKS71HVMG 21.5 (760) 340 x 1,200 x 240 17 RKS71HVMG 2.3 52/49 770 x 900 x 320 71 9.5 Measurement conditions 1. capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; piping length 7.5 m. 2. Sound levels are based on the temperature conditions 1. above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions. 19

FTKD25/35G name Rated (Min.-Max.) Power supply Running current Rated Power consumption Rated (Min.-Max.) COP Rated Front panel colour Airflow rate (H) Fan speed Sound levels (H/L/SL) Dimensions (H x W x D) Machine weight Casing colour Type Compressor Refrigerant charge (R-22) Sound levels (H/L) Dimensions (H x W x D) Machine weight Operation range Piping connections Max. piping length Max. height difference FTKD series Motor output Liquid Gas Drain A W W/W m 3 /min (cfm) db (A) W db (A) CDB m FTKD25GVM RKD25GVM 2.5 (1.2-3.2) 8,500 (4,050-10,900) 3.9 685 (294-1,100) 3.65 FTKD25GVM 8.9 (314) 37/28/25 RKD25GVM 0.75 46/43 32 9.5 1 phase, 220-240 V / 220-230 V, 50/60 Hz White 5 steps, quiet and automatic 283 x 800 x 195 9 Ivory white Hermetically sealed swing type 600 550 x 765 x 285 19.4 to 46 6.4 18.0 25 15 FTKD35GVM RKD35GVM 3.2 (1.4-4.0) 10,900 (4,750-13,650) 4.2 888 (301-1,429) 3.60 FTKD35GVM 9.0 (318) 39/29/26 RKD35GVM 0.90 47/44 34 12.7 FTKD series FTKD42/50/60/71G name Power supply Running current Power consumption COP Front panel colour Airflow rate (H) Fan speed Sound levels (H/L/SL) Dimensions (H x W x D) Machine weight Casing colour Rated (Min.-Max.) Rated Rated (Min.-Max.) Rated Type Compressor Motor output Refrigerant charge (R-22) Sound levels (H/L) Dimensions (H x W x D) Machine weight Operation range Liquid Piping connections Gas Drain Max. piping length Max. height difference A W W/W m 3 /min (cfm) db (A) W db (A) CDB m FTKD42GVM RKD42GVM 4.2 (2.0-5.0) 14,300 (6,800-17,100) 5.4 1,167 (520-1,600) 3.60 FTKD42GVM 15.3 (540) 42/36/33 RKD42GVM 600 1.10 49/44 550 x 765 x 285 35 25 15 12.7 FTKD50GVM RKD50GVM 5.2 (1.5-5.9) 17,700 (5,100-20,100) 1 phase, 220-240 V / 220-230 V, 50/60 Hz 7.3 9.2 1,575 (420-2,300) 2,000 (440-2,600) 3.30 3.10 FTKD50GVM FTKD60GVM White 17.5 (618) 5 steps, quiet and automatic 44/35/32 45/36/33 290 x 1,050 x 250 12 RKD50GVM RKD60GVM Ivory white Hermetically sealed swing type 1,500 1.00 49/44 43 6.4 FTKD60GVM RKD60GVM 6.2 (1.5-6.5) 21,200 (5,100-22,200) 1.50 50/46 735 x 825 x 300 47 19.4 to 46 18.0 30 20 15.9 FTKD71GVM RKD71GVM 7.1 (2.1-7.6) 24,200 (7,200-25,900) 11.5 2,491 (540-3,176) 2.85 FTKD71GVM 18.3 (646) 46/37/34 RKD71GVM 1,900 1.60 53/49 53 9.5 Measurement conditions 1. capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; piping length 7.5 m. 2. Sound levels are based on the temperature condition 1. above. These are anechoic values. These values are normally somewhat higher during actual operation as a result of ambient conditions. 20

Specifications FT series FT25/35/50/60H name FT25HV1 R25HV1 2.60 8,900 Power supply Running current A 3.4 Power consumption W 792 COP W/W 3.28 FT25HV1 Front panel colour Airflow rate (H) m 3 /min (cfm) 9.6 (339) Fan speed Sound levels (H/L) db (A) 37/28 Dimensions (H x W x D) Machine weight R25HV1 Casing colour Compressor Type Motor output W 700 Refrigerant charge (R-22) 0.60 Sound levels db (A) 49 Dimensions (H x W x D) 550 x 658 x 275 Machine weight 27 Operation range CDB Liquid Piping connections Gas 9.5 Drain Max. piping length Max. height difference m Note: The above values are based on operation with a 230 V, 50 Hz power supply. 283 x 800 x 195 9 25 FT35HV1 R35HV1 3.60 12,300 4.8 1,097 3.28 FT35HV1 White 9.9 (350) 17.5 (635) 18.5 (653) 5 steps and automatic 40/31 45/35 47/36 290 x 1,050 x 238 12 R35HV1 R50HV1 R60HV1 Ivory white Hermetically sealed rotary type 1,000 0.95 49 550 x 765 x 285 34 1,530 1.15 52 595 x 845 x 300 37 2,850 2.00 54 770 x 900 x 320 62 12.7 FT50HV1 R50HV1 5.20 17,750 1 phase, 220-240 V, 50 Hz 19.4 to 46 6.4 18.0 15 7.1 1,585 3.28 FT50HV1 15.9 30 FT60HV1 R60HV1 6.60 22,530 9.2 2,012 3.28 FT60HV1 Measurement conditions 1. capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; piping length 7.5 m. 2. Sound levels are based on the temperature condition 1. above. These are anechoic values. These values are normally somewhat higher during actual operation as a result of ambient conditions. FTE series FTE25/35/50/60K name Max. piping length Max. height difference Power supply Running current Power consumption COP Front panel colour Airflow rate (H) Fan speed Sound levels (H/L) Dimensions (H x W x D) Machine weight Casing colour Type Compressor Motor output Refrigerant charge (R-22) Sound levels Dimensions (H x W x D) Machine weight Operation range Liquid Piping connections Gas Drain A W W/W m 3 /min (cfm) db (A) W db (A) CDB FTE25KV1 RE25KV1 2.60 8,900 3.5 812 3.20 FTE25KV1 Note: The above values are based on operation with a 230 V, 50 Hz power supply. m FTE35KV1 RE35KV1 3.35 11,450 4.9 1,115 3.00 FTE35KV1 White 9.6 (339) 9.9 (350) 18.5 (653) 5 steps and automatic 37/28 39/33 48/35 48/36 283 x 800 x 195 290 x 1,050 x 238 9 12 RE25KV1 RE35KV1 RE50KV1 RE60KV1 Ivory white Hermetically sealed rotary type 700 0.60 49 1,000 1.00 50 27 9.5 550 x 658 x 275 Measurement conditions 1. capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; piping length 5 m. 2. Sound levels are based on the temperature condition 1. above. These are anechoic values. These values are normally somewhat higher during actual operation as a result of ambient conditions. 30 12.7 FTE50KV1 RE50KV1 5.20 17,750 1 phase, 220-240 V, 50 Hz 19.4 to 46 6.4 18.0 20 15 7.9 1,735 3.00 FTE50KV1 1,300 0.90 53 595 x 845 x 300 36 15.9 FTE60KV1 RE60KV1 6.40 21,800 9.2 2,135 3.00 FTE60KV1 1,600 1.56 55 735 x 825 x 300 53 21

Options No. 1 2 3 4 Item 5-room centralized controller Wiring adaptor for time clock/remote controller (Normal open pulse contact/normal open contact) Titanium apatite photocatalytic air-purifying filter Remote controller loss prevention with chain Notes: *1. A wiring adaptor (KRP413AB1S) is also required for each indoor unit. *2. The time clock and other devices should be obtained locally. *3. The filter is a standard accessory. It should be replaced approximately every 3 years. * 1 * 2 * 3 FTKS 25/35D FTKS 50/60G KAF970A46 KAF952B42 KKF917A4 FTKS 71H KAF970A48 KKF910A4 FTKD25/35/ 42/50/60/71G KRC72 KRP413AB1S FT25/35H FTE25/35K KAF970A46 KKF917A4 FT50/60H FTE50/60K KAF952A42 Titanium apatite photocatalytic air-purifying filter KAF970A46 Titanium apatite photocatalytic air-purifying filter KAF952B42 Titanium apatite photocatalytic air-purifying filter KAF970A48 5-room centralised controller KRC72 Remote controller loss prevention with chain KKF917A4 Remote controller loss prevention with chain KKF910A4 No. Item 1 Air direction adjustment grille 2 Drain plug Note: *1. One set includes 5 pieces for 5 units. RKS RKS RKS 25/35G 50/60G 71H KPW937A4 KPW945A4 KKP937A4 KKP945A4 RKD25/35/ 42/50/60/71G R25/35H RE25/35K KPW937A4 KKP937A4 R50/60H RE50/60K Air direction adjustment grille KPW945A4 Drain plug KKP937A4 Drain plug KKP945A4 Control system No. Item FTKS 25/35D FTKS 50/60G FTKS 71H 1 2 3 4 Central remote controller Unified On/Off controller Schedule timer Interface adaptor for DIII-NET use * 1 * 1 * 1 DCS302CA61 DCS301BA61 DST301BA61 KRP928BB2S Note: *1. Interface adaptor for DIII-NET use (KRP928BB2S) is also required for each indoor unit. FTKD25/35/ 42/50/60/71G FT25/35H FTE25/35K FT50/60H FTE50/60K Central remote controller DCS302CA61 Unified On/Off controller DCS301BA61 Schedule timer DST301BA61 Specifications are subject to change. 22

Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for use, in the region where the product will be used. This statement does not purport to exclude, restrict or modify the application of any local legislation. Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion. Read the User s Manual carefully before using this product. The User s Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. If you have any enquiries, please contact your local importer, distributor and/or retailer. Cautions on product corrosion 1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced. 2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor. JMI-0107 Organization: DAIKIN INDUSTRIES, LTD. AIR CONDITIONING MANUFACTURING DIVISION Scope of Registration: THE DESIGN/DEVELOPMENT AND MANUFACTURE OF COMMERCIAL AIR CONDITIONING, HEATING, COOLING, REFRIGERATING EQUIPMENT, HEATING EQUIPMENT, RESIDENTIAL AIR CONDITIONING EQUIPMENT, HEAT RECLAIM VENTILATION, AIR CLEANING EQUIPMENT, COMPRESSORS AND VALVES. JQA-1452 Organization: DAIKIN INDUSTRIES (THAILAND) LTD. Scope of Registration: THE DESIGN/DEVELOPMENT AND MANUFACTURE OF AIR CONDITIONERS AND THE COMPONENTS INCLUDING COMPRESSORS USED FOR THEM All of the Daikin Group s business facilities and subsidiaries in Japan are certified under the ISO 14001 international standard for environment management. Dealer DAIKIN AIRCONDITIONING (MALAYSIA) SDN BHD (367633-W) Tel: 03-7955 9090 Fax: 03-7954 1529 03-7954 7722 03-7955 1685 (Service) Penang Branch: Tel: 04-310 1999 Fax: 04-310 1998 Johor Branch: Tel: 07-354 2582 Fax: 07-354 2576 Email: service@daikin.com.my sales@daikin.com.my Website: www.daikin.com.my Head Office: Umeda Center Bldg., 2-4-12, Nakazaki-Nishi, Kita-ku, Osaka, 530-8323 Japan Tokyo Office: JR Shinagawa East Bldg., 2-18-1, Konan, Minato-ku, Tokyo, 108-0075 Japan http://www.daikin.com/global_ac/ c All rights reserved Printed in Malaysia 01/12 P.C. Specifications, designs and other content appearing in this brochure are current as of January 2012 but subject to change without notice.