SECTION LABORATORY and DE-IONIZED WATER SYSTEMS STANDARD CONSTRUCTION STANDARD

Similar documents
C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

SECTION DOMESTIC WATER PIPING SPECIALTIES

A. This Section includes the following domestic water piping specialties:

WATERSTONE ASSISTED LIVING AND MEMORY CARE

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES

A. Piping specialties Work required by this Section is indicated on drawings and schedules and by requirements of this Section.

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

SECTION DOMESTIC WATER AND DRAINAGE PIPING SPECIALTIES

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following sanitary drainage piping specialties:

VALVES SECTION 15100

B. Shop Drawings: Detail fabrication of pipe anchors, hangers, special pipe support assemblies, alignment guides, expansion joints and loops,

Division 23 - HVAC Switzerland Beallsville K-12. Section HYDRONIC PIPING SECTION HYDRONIC PIPING PART 1 - GENERAL

SECTION HYDRONIC PIPING AND SPECIALTIES

SECTION SECTION DESIGN REQUIREMENTS

SECTION BASIC MATERIALS AND METHODS

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION PLUMBING SPECIALTIES

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

PRICE BOOK CONTENTS 010 PIPE

Valve Pressure and Temperature Ratings: Not less than indicated and as required for system pressures and temperatures.

DARTMOUTH COLLEGE DESIGN November 15, 2007 & CONSTRUCTION GUIDELINES

SECTION FIRE PROTECTION. A. Examine all conditions as they exist at the project, prior to submitting a bid for the work of this section

PROJECT NAME: DPW Idaho State University Liberal Arts Building Chiller Replacement

University of Delaware

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

SECTION HYDRONIC PIPING

FIRE SUPPRESSION SPRINKLER SYSTEM

PROJ. NO SECTION HYDRONIC PIPING

PROJ. NO SECTION REFRIGERANT PIPING

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES

DUKE UNIVERSITY CONSTRUCTION STANDARDS

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

BSHM ARCHITECTS, INC. 15 Central Square, Suite 300 Youngstown, Ohio 44503

REFRIGERANT PIPING SYSTEM

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

HVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

SPRINKLERS TABLE OF CONTENTS

B. Related Sections: The following Sections contain requirements that relate to this Section.

MLA Architects Pierz Public Schools ISD #484 Healy High School Multi-Purpose & Choir Additions Pioneer Elementary School Class Room Addition Pierz, MN

SECTION PLUMBING EQUIPMENT

2016 CDM Smith All Rights Reserved July 2016 SECTION PLUMBING - EQUIPMENT

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION ELECTRIC WATER HEATERS

1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following:

SECTION PLUMBING

COBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point.

Ratio Architects, Inc. Section Refrigerant Piping

SECTION (15530) - REFRIGERANT PIPING

A. This Section includes the following emergency plumbing fixtures:

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6

NATURAL GAS PIPING

D-8 OUTLINE SPECIFICATION FOR HTHW HEAT EXCHANGERS

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

B. Shop Drawings: Include diagrams for power, signal, and control wiring.

LAV FCO WCO NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.

WET-PIPE SPRINKLER SYSTEMS

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

Lee s Summit West High School Boiler #3 Replacement SECTION CONDENSING BOILERS

SECTION DRY-PIPE SPRINKLER SYSTEMS

HWC NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.

SECTION (15530) - REFRIGERANT PIPING

SECTION WET-PIPE SPRINKLER SYSTEMS

HYDRONIC SPECIALTIES TACO AC(F)-CA 05/08/2008

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

Design and Construction Standards SECTION PLUMBING EQUIPMENT

SECTION WET-PIPE SPRINKLER SYSTEMS

A. This Section includes the following fire-suppression piping inside the building:

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

REFRIGERANT PIPING

DUKE UNIVERSITY DESIGN GUIDELINES

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

A. General provisions and other plumbing systems are specified in other Sections of Division 22.

DOMESTIC WATER PACKAGED BOOSTER PUMPS

North Hanover Township School District North Hanover Township, New Jersey

D-11 OUTLINE SPECIFICATION FOR HTHW (ABOVE GRADE) HYDRONIC PIPING

A. Standard-Pressure Piping System Component: Listed for 175-psig minimum working pressure.

DESIGN STANDARDS SECTION PLUMBING FIXTURES AND EQUIPMENT. 1.3 Wall hung toilet room fixtures. Urinals for handicapped may be stall type.

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 21 FIRE SUPPRESSION

PLUMBING DESIGN GUIDELINES SECTION DESIGN GUIDELINES DUVAL COUNTY PUBLIC SCHOOLS

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

HYDRONIC SPECIALTIES TACO MPT Tank(s) 05/30/2012. A. Multi-Purpose Tank buffer tank, air separator, and hydraulic decoupler

2016 CDM Smith All Rights Reserved July 2016 SECTION FIRE PROTECTION - SPRINKLER AND STANDPIPE SYSTEMS

DESIGN GUIDELINES AND TECHNICAL STANDARDS

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

SECTION PLUMBING EQUIPMENT

A. All fixtures shall meet the requirements of ANSI A117.1, ANSI Z124.2 and the State of Texas Accessibility Standards (TAS).

A. Section Joint Sealants: Seal fixtures to walls and floors.

TABLE OF CONTENTS DIVISION 22 - MECHANICAL

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

Wayne State University WSU Project No Chatsworth Tower Apts. Misc. Bldg. Upgrades DSD Project No

Transcription:

PART 1: GENERAL 1.01 Codes and Standards: A. Plumbing Code Compliance: Comply with applicable portions of National Standard Plumbing Code pertaining to selection and installation of Plumbing materials and products. Laboratory water is that which is downstream of a backflow preventer. B. The design guidelines contained herein include the requirements for systems, materials, fittings and valves utilized for piping systems at The University of Texas at Austin. It is the intention of this document to provide a standard for piping systems at The University in order to provide the highest level of quality and standardization possible; it is not intended to be a guide specification C. The UT-Austin campus has a central system for distribution of deionized water (DW). (For historical reasons, we often still call it distilled water.) The DW is carried in pressurized PVC Schedule 80 lines in the utility tunnels. D. For buildings that need DW, we take a small (1 ) PVC 80 line from the tunnel DW main up to a non-pressurized DW tank in the attic. There is a stainlesssteel orifice in the line (1/4 for buildings with large DW demand, 1/8 for buildings with small demand) to limit the amount of makeup to the tank. A stainless-steel solenoid valve maintains the level in the DW tank. A larger PVC line (often 2 inch) lets DW flow by gravity from the tank to the building uses. There is a detail of a typical DW tank and controls. E. Avoid 2-1/2, 3-1/2 and 5-inch pipe in deionized-water systems. F. An ultraviolet sterilizer shall be installed in the piping downstream of the DW storage tank. G. Storage tank shall be provided with tank level sight glass. Sight glass shall be piped external to tank and be provided with isolation service valves at top and bottom of glass. Sight glass shall be equipped with high and low level switches. Switches shall be located within the section of sightglass isolated by service valves. Switches shall provide dry contacts for reporting conditions to BAS/FCMS system. PART 2: PRODUCTS 2.01 Materials and Products: A. General: The following are materials and product standards to be followed in the design of domestic water systems. Design & Construction Standards, Revised May 6, 2002 15160-1

2.02 Standards for Basic Identification: A. General: Piping identification Standard at the University is ANSI A13.1 "Scheme for Identification of Piping Systems. All piping shall have flow arrows indicating direction of flow. 2.03 Basic Pipes and Pipe Fittings: A. General: The following listing is to be used as the standard for domestic and laboratory water pipes and fittings: B. Interior Laboratory Water Piping: 1. Tube Size 3" and Smaller: Copper tube; Type L, hard-drawn temper; wrought-copper fittings, lead free jointing (Silvabrite) for cold water. For hot water above 160 degrees, use Type K copper tubing with lead free jointing (Silvabrite). 2. Pipe Sizes 4 and Larger: Steel pipe with mechanical joints. C. Exterior or Below Grade Laboratory Water Piping: 1. Tube Size 3/4" and Smaller: Copper tube; Type K, soft-annealed temper; cast-copper flared tube fittings. 2. Tube Size 1" and larger Copper tube; Type K, soft-annealed temper; wrought-copper fittings, lead free jointing (Silvabrite). 2.04 De-Ionized Water Piping: A. PVC, Type DWV Pipe and Fittings: ASTM D2665 pipe and fittings, with solvent cemented joints; DWV plastic fitting patters shall conform to ASTM D3311. B. Solvent: ASTM D2564. 1. When designing De-ionized water delivery systems for low meg-ohm water (laboratory grade 1-2 meg-ohm) a recirculating system is not required. Point of use polishing utilizing de-mineralized water from the central system is the standard design for production of lab-grade de-ionized water. 2.05 Basic Piping Specialties Standard: A. General: Provide piping specialties in accordance with the following standard listing: B. Basket Strainers: Provide basket strainers with cast-iron body, 125-psi flanges, Design & Construction Standards, Revised May 6, 2002 15160-2

bolted type or yoke type cover. Furnish with removable, non-corrosive perforated strainer basket, with 1/8" perforations and lift-out handle. C. Available Manufacturers: Subject to compliance with requirements, manufacturers offering basket strainers which may be incorporated in the work include, but are not limited to, the following: 1. Josam Mfg. Co. 2. Metraflex Co. 3. Spirax Sarco 4. Smith (Jay R.) Mfg. Co. 2.06 Basic Supports and Anchors: A. General: Provide supports and anchors in accordance with the following listing: 2.07 Basic Valves: 1. Adjustable steel clevises and adjustable pipe saddle supports are Standard for horizontal piping hangers and supports. 2. Two-bolt riser clamps are Standard for vertical piping supports. 3. Concrete inserts, C-clasps, and steel brackets are Standard for building attachments. 4. Protection shields are Standard for insulated piping support in hangers. A. General: The following valves are Standard in application at the University of Texas: B. Section Valves: 1. 2" and Smaller: Gate valves or ball valves 2. 2 1/2" and Larger: Gate valves or butterfly valves C. Shutoff Valves: 1. 2" and Smaller: Gate valves or ball valves. 2. 2 1/2 or Larger: Gate valves or butterfly valves D. Drain Valves: 1. 2" and Smaller: Gate valves or ball valves. 2. 2 1/2 and Larger: Gate valves. E. Check Valves: Design & Construction Standards, Revised May 6, 2002 15160-3

1. All Sizes: Swing check valves. 2. See Section 15100 F. Plug Valves: 2.08 Bibbs and Faucets: 1. For use on natural gas, use valves approved by University of Texas Utilities Department and AGA approved. A. Hose Bibbs: 2.09 Hydrants: 1. Threaded End: Bronze body, renewable composition disc, tee handle, 3/4" NPT inlet, 3/4" hose outlet. B. Sill Faucets: Bronze body, renewable composition disc, wheel handle, 3/4" solder inlet, 3/4" hose outlet. C. Available Manufacturers: Subject to compliance with requirements, manufacturers offering bibbs and faucets, which may be incorporated in the work, include, but are not limited to, the following: 1. Hammond Valve Corp. 2. Lee Brothers; Div. Phelps Dodge Brass Co. 3. Mansfield Plumbing Products. 4. Nibco Inc. 5. Prier Brass mfg. Co. 6. Tanner Mfg. Co. 7. Watts Regulator Co. A. Recessed Non-Freeze Wall Hydrants: Case-bronze casing, length to suit wall thickness, vacuum breaker, hinged locking cover, 3/4" inlet, hose outlet. B. Project Non-Freeze Wall Hydrants: Cast-bronze hydrant, chrome plate face, tee handle key, bronze casing, length to suit wall thickness, vacuum breaker, 3/4" inlet hose outlet. C. Projected Non-Freeze Wall Hydrants: Cast-bronze hydrant, chrome plated face, tee handle key, bronze casing, length to suit wall thickness, vacuum breaker, 3/4" inlet hose outlet. D. Floor Level Non-Freeze Hydrants: Bronze hydrant, rough bronze box, tee handle key, bronze casing, length to suit depth of bury, drain hole, vacuum breaker, hinged locking cover, 3/4" inlet, hose outlet. Design & Construction Standards, Revised May 6, 2002 15160-4

E. Non-Freeze Post Hydrants: Bronze hydrant, tee handle key, bronze casing with cast-iron casing guard, length to suit depth of bury, drain hole, vacuum breaker, 3/4" inlet, hose outlet. F. Available Manufacturers: 2.10 Backflow Preventers: 1. Josam Mfg. Co. 2. Smith, (Jay R.) Mfg. Co. 3. Tyler Pipe; Sub. of Tyler Corp. 4. Woodford Mfg. Co. 5. Zurn Industries Inc., Hydromechanics Div. A. General: The standard back flow preventer is of the reduced pressure zone (RPZ) type, the assembly including shutoff valves on inlet and outlet, and strainer on inlet. Backflow preventers shall include test cocks, and pressuredifferential relief valve located between 2 positive seating check valves. Construct in accordance with ASSE Standard 1013. The exact model of the backflow preventor shall be coordinated with the Owner prior to incorporation into the design. B. Available Manufacturers: Subject to compliance with requirements, manufacturers offering backflow preventers which may be incorporated in the work include, but are not limited to, the following: 1. Febco Sales, Inc.; Subs. of Charles M. Bailey Co., Inc. 2. Hersey Products, Inc. 3. ITT Lawler; Fluid Handling Div. 4. Watts Regulator Co. 2.11 Pressure Regulating Valves: A. General: The standard pressure regulating valve is single seated, direct operated type, bronze body, integral strainer, complying with requirements of ASSE Standard 1003. B. Available Manufacturers: 2.12 Relief Valves: 1. Cash (A.W.) Valve Mfr. Corp. 2. Cla-Val Co. 3. Spencer Engineering Co., Inc. 4. Watts Regulator Co. A. General: The standard relief valves are to be manufactured in accordance with Design & Construction Standards, Revised May 6, 2002 15160-5

ASME Boiler and Pressure Vessel Code and are of the following configurations: 1. Combined Pressure-Temperature Relief Valves: Bronze body, test lever, thermostat, complying with ANSI 22l.22 listing requirements for temperature discharge capacity. Provide temperature relief at 210 o F (99 o C), and pressure relief at 150 psi. B. Available Manufacturers: PART 3: EXECUTION 3.01 General: 1. Cash (A.W.) Valve Mfg. Corp. 2. Conbraco Industries, Inc. 3. Watts Regulator Co. 4. Zurn Industries, Inc.; Wilkins-Regulator Div. A. Locate groups of pipes parallel to each other, spaced to permit applying full insulation and servicing of valves. 3.02 Installation of Valves: 1. Provide clean-out capability for domestic hot water return piping in recirculating loops. There may be a capped tee at each ninety-degree turn in the piped return system. A. Sectional Valves: Install on each branch and riser, close to main, where branch or riser serves 2 or more plumbing fixtures or equipment connections. B. Shutoff Valves: Install on inlet of each plumbing equipment item, and on inlet of each plumbing fixture. C. Drain Valves: Install on each plumbing equipment item located to completely drain equipment for service or repair. Install at base of each riser, at base of each rise or drop in piping system, and elsewhere where indicated or required to completely drain potable water system. D. Check Valves: Install on discharge side of each pump. E. Balance Cocks: Install in each hot water recirculating loop. F. Hose Bibbs: Install on exposed piping where indicated, with vacuum breaker. G. Sill Faucets: Install on concealed piping where indicated with vacuum breaker. Design & Construction Standards, Revised May 6, 2002 15160-6

3.03 Installation of Backflow Preventers: A. Install backflow preventers where required by National Standard Plumbing Code. Locate in same room as equipment being protected. Pipe relief outlet to nearest floor drain. B. Backflow preventers shall be installed at any connection between potable and non-potable water systems. 3.04 Installation of Pressure Regulating Valves: A. Provide inlet and outlet shutoff valves, and throttling valve bypass. Provide pressure gage on valve outlet. 3.05 Equipment Connections: A. Piping Runouts to Fixtures: Provide hot and cold water piping runouts to fixtures of sizes indicated, but in no case smaller than required by National Standard Plumbing Code. B. Mechanical Equipment Connections: Connect hot and cold water piping system to mechanical equipment as indicated, and comply with equipment manufacturer's installation instructions. Provide shutoff valve and union for each connection, provide drain valve on drain connection. END OF STANDARD 15160 Design & Construction Standards, Revised May 6, 2002 15160-7