REFRIGERANT RECOVERY DEVICES AND ACCESSORIES

Similar documents
Refrigerant Recovery Unit, Model RRU134

REFRIGERANT RECOVERY SYSTEMS

OPERATING INSTRUCTIONS

YELLOW JACKET Recovery Machines for every refrigerant, every size system

RecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual

Operation and Maintenance Manual

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge

Fluid Exchange. Refrigerant Handling Systems Recovery/Recycling Systems Fluid Exchangers Flushers Fluid Exchange Accessories BUYER'S GUIDE

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

Product Data. Features/Benefits. 19XB Positive Pressure Storage System

Temptek Auxiliary Equipment

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

OPERATING INSTRUCTIONS

Nirvana. Cycling Refrigerated Dryers

AIR CONDITIONNING 95 CODE 002

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

OPER LV Wheeler Way

ariazone 601HD Refrigerant Recovery & Recycling Unit User's manual

OPERATING INSTRUCTIONS

Refrigerant Recovery/Recharging Series

NQ Series Portable Chillers

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

Air-Cooled Condensing Units with Compact Screw Compressors

RECOVERY EQUIPMENT RECOVER REFRIGERANTS QUICKLY & EFFICIENTLY

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Screw Compressors AS SERIES. Capacities from: 59 to 124 cfm Pressures from: 80 to 217 psig

Caresaver Universal Refrigerant Recovery Unit

Some of these procedures need to be performed to conform to requirements of the Clean Air Act.

OPERATION & MAINTENANCE MANUAL TX600

Product Data. Features/Benefits ComfortLink control

YOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE.

Compressed Air Packages

TOOLS AND INSTRUMENTS

Screw Compressors SM SERIES. Capacities from: 16 to 54 cfm Pressures from: 80 to 217 psig

Ariazone 601HD Refrigerant Recovery&Recycling unit

MAXIMUM SERIES. Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 70 F chilled water.

REFRIGERATION PRODUCTS

347002K/177002K/34900

AUXILIARY EQUIPMENT FOR ALL YOUR NEEDS

Recirculating Coolers

R100 Oil-Less Refrigerant Recovery Unit

Freeze Dry Systems and Accessories

Nirvana Cycling Refrigerated Dryers

RIGID DC LIQUID CHILLER

Precise Temperature Control; Compact Footprint

OWNER S MANUAL (English)

SECTION REFRIGERATION. 1. Reciprocating Compressors (Hermetic). 2. Reciprocating Compressors (Open Drive). 3. Water Cooled Condensing Units.

Guide Specifications for InRow Direct Expansion

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

OACS Outdoor Air-Cooled Central Chillers

SENTRA Series Water Unit

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

CentriVap. Centrifugal Vacuum Concentrators and Cold Traps

OWNER S MANUAL (English)

SpeedClean. Work Smarter NEW! Innovative cleaning products for maximum HVAC system efficiency. Innovative Maintenance Tools.

Used Fluid Handling Portable Used Oil Gravity Drains

AQUASNAP JUNIOR 30RHV

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

Freeze Dry Systems and Accessories

SINGLE STAGE MULTI STAGE NANO MICRO

Circulating Water Temperature Controller

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

EVAC TM commercial CRH-500

REFRIGERATION PRODUCTS

DEEP VACUUM: ITS PRINCIPLE AND APPLICATION

30 F to 300 F Process Temperatures* 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 3/8-1 Solenoid Cooling Valves (VE & 300 F models)

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.

Section 2. Air Conditioning & Cooling System Service Equipment. Section 2: Suppliers: CALL:

REFRIGERANT SERVICE TOOLS VACUUM PUMPS / ACCESSORIES

TECHNICAL SPECIFICATIONS. MEXICO - HCFC PHASE-OUT MANAGEMENT PLAN (HPMP) Stage II EQUIPMENT FOR REFRIGERATION RECLAMATION CENTRES.

StableClimate Stability Chambers

TRS21 IGNITION PROOF SERIES

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

MAC N-407 Air-Cooled Chiller

Refrigeration Plant Information. We Speak Hockey 365

500 EX Fusion Compressor Series

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

Freeze Dry Systems and Accessories

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

TRS21 IGNITION PROOF SERIES

SECTION 50 - CAB CLIMATE CONTROL

Enspeco RMS. The Enspeco Refrigerant Management. The following instructions will INSTRUCTIONS

Pro-Set TRA21 SERIES Mobile Multiple Refrigerant Recovery / Recycle System

TRIDENT GS SERIES Central Chiller

AS950 REFRIGERATED SAMPLERS

Using the DewTrak II Dew Point/ Humidity Transmitter

HSXA15 HSXB15. IMPORTANT Operating pressures of this R410A unit are higher than pressures in R22 units. Always use service equipment rated for R410A.

Thermo Scientific Air Cadet

Using the Model 1500 Portable Chilled Mirror Hygrometer

REFRIGERATION PRODUCTS

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration

VWR Laboratory Refrigerators and Freezers

Integrated Process Solutions. Series 48 Heaters. heater jackets sizes 1 1/2'' to 4'' (nw 40 to nw 100)

INFICON Service Tools A Catalog For Service Professionals

Measurement Solutions for Refrigeration Technology.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

For Modules: ASM002X, ASM003X, ASM005X, ASM008X, ASM010X, ASM015X, ASM020X, ASM030X. Air Cooled Medical Chiller Product Data Catalog

Enclosed Scroll Air Compressor System SES 3-5 HP

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

Transcription:

DEVICES AND ACCESSORIES DEVICES AND ACCESSORIES PROMAX RECOVERY DEVICES PROMAX designs, engineers, and manufacturers the highest quality service equipment and makes it easy to use for all refrigerant handling industries. For the last two decades, the team at PROMAX has been producing machines for service contractors that help them PRO-fit MAX-imize their work in the field. RG5410A HIGH PRESSURE OIL-LESS SYSTEM Recovers all commonly used CFC, HFC, HCFC Refrigerants (including R-410A [Puron ]). Designed for use with High Pressure refrigerants. Selectable High Pressure safety cut off switches (400-550 psi). Proprietary Oil-less compressor capable of handling both liquid and vapor. All new ergonomic design for easier handling. 3/8-3-row condenser for maximum performance in even the harshest conditions. Corrosion proof polyethylene blow molded case. Field serviceable semi-hermetic compressor. Self-purge feature. Includes Filter-Drier. All units pre-wired to accept 80% Tank Shut Off Kit (Part No. KT5001). RG5410A-KT available with Optional 80% Tank Shut Off Kit installed at the factory. Power Source 115 V 60 Hz. ADS-100 CHARGING & RECOVERY SCALE One of the most invaluable and versatile tools for handling refrigerant. Accounts for all recovered or sold refrigerant with 176 lb/80 kg capacity and ± 1% accuracy. Calibrated to N.I.S.T. standards and operative in temperatures ranging from 32 F to 120 F. INFICON RECOVERY DEVICES THE VORTEX UNIT Vortex is the recovery machine for technicians who want a high performance, durable and compact unit at a competitive price. Vortex provides rapid recovery of all refrigerants. Individual valves with dual-sealed stems greatly reduce the potential for leaks. The enlarged, strategically placed fan provides for better airflow over the condenser as well as the compressor, allowing for improved cooling and lower pressures. Its cutting-edge condenser design makes for less air restriction, more direct heat transfer and improved durability. The single-valve, liquid tolerant, oil-less compressor with 1/3 HP DC motor drive, can stand up to heavy use and liquid slugs. And of course, Vortex is backed up with the superior support and service you expect from Inficon. Vortex comes with a sturdy carrying strap. Features at a Glance: Self-purges without the need to change hoses. Gauges are protected, yet accessible for quick, easy change. Textured, reflective handle stays cooler in direct sunlight. Revolutionary condenser design for more efficient heat transfer and lower head pressures. Large rear-mounted fan provides exceptional cooling. Individual valve assembly eliminates leaks. 1/3 HP motor drives the single valve, liquid-tolerant, oil-less compressor for high recovery rates. Optional overflow protection device is easily installed (Sold Separately). Part No. 708-202-G1 WEY-TEK REFRIGERANT CHARGING SCALE The Wey-TEK Refrigerant Charging Scale is an affordable, precision electronic scale that lets you easily weigh and charge from the same large platform. Its high-accuracy load cell gives the correct reading each time no matter where the cylinder is on the weighing platform. The optional Wey-TEK Charging Module will allow you to turn your Wey-TEK Refrigerant Scale into an automatic charging station. Features at a Glance: Wey-TEK Refrigerant Scale. Precision-designed for refrigerant charging and recovery. High-accuracy load cell won t drift. Transfers all refrigerant by weight. Measures in lb or kg. Large LCD display for easy viewing. Lightweight, modular design of high-impact foam-mold Part Numbers 110 lb. scale 707-600-G1 220 lb. scale 707-220-G1 WEY-TEK CHARGING MODULE Charging module offers charge/hold key to allow interruption of the charging process. Displays target charge and total refrigerant transferred. Part No. 709-700-G1 720

EVAC COMMERCIAL OPEN DRIVE HIGH PRESSURE RECOVERY SYSTEM Shaves hours off recovery times on chillers and large A/C or refrigeration systems. FASTER SPEED Recovers 325-lb/min liquid and 6-lb/min vapor (R-22). HIGH DURABILITY Rugged 3-Hp open drive compressor provides years of reliable service, even on refrigerants heavily contaminated with oil, air, moisture, and acids. SERVICES MOST HP REFRIGERANTS R-12, R-22, R-114, R-134a, R-404, R-407, R-500, R-502, R-507, MP39 and other high pressure refrigerants or blends (does not service very high pressure refrigerants such as R-13 and R-23). EASY OPERATIONS Purging lines and switching from liquid to vapor recovery modes simply involves turning three 3-way hand valves and rerouting a hose. Liquid Push/Pull (R-22) 325 lb/min Vapor Rate (R-22) 6.0 lb/min Final Vacuum 15-in. Hg Motor 3 Hp Power: Controls 103-127 VAC, 50/60 Hz, 1φ, 15A Connections 3/4 in. flare Dimensions (L x W x H) Electromechanical 32 in. x 29 in. x 45 in.(114 cm) Weight Electromechanical: 310 lb Shipping: 375lb. Included with Purchase: 3 Ph units have separate 115V Controls Power cord. Two cords total. Two each 3/4-5/8 and 5/8-1/2 reducing fittings -Two 48-in3 filter drier cores -One 3/4 in. x 20 ft hose -Two 3/4 in. x 10 ft hoses FD-048-CR 075-020-HP-FB 075-010-HP-FB Spare filter driers 48-in3 FD-048-CR filter drier cores Compressor fluid, 1 gal OIL-POE-1G 100, 250 and 1,000 lb tanks with 3/4 in. ports and dip tubes Custom sized ASME tanks NOMENCLATURE 721

LOVAC LOW PRESSURE RECOVERY SYSTEM LOVAC outpaces other recover systems, especially when refrigerant is contaminated with moisture, oil, or noncondensibles FASTER SPEED Recovers R-11 at 100-lb/min liquid and 0.66-lb/min vapor. NONCONDENSIBLES? NOT AN ISSUE! LOVAC s compressor works against very high head pressures and the water cooled condenser and subcools recovered refrigerant to minimize the effects of noncondensibles. HIGH DURABILITY Rugged 2.0 Hp open drive compressor stands up to difficult recovery conditions better than vacuum pumps. REFRIGERANT COMPATIBILITY Services all low pressure refrigerants. Switching between R-11, R-123, and R-113 simply involves evacuating the recovery unit, changing fluid and replacing two external filters. EASY OPERATION Purging lines and switching from liquid to vapor recovery modes simply involves turning three valves and rerouting hoses. Included with Purchase: Recovery Rates (R-11) One power cord 50 ft. Open Drive Model Two each 3/4-5/8 and 5/8- Liquid = 100-b/min 1/2 reducing fittings Vapor = 0.66-lb/min -Two 48-in3 filter drier FD-048-CR Final Vacuum: 29-in Hg cores -One 3/4 in. x 20 ft hose 075-020-HP-FB Power: Recovery Unit -Two 3/4 in. x 10 ft hoses 075-010-HP-FB 103-127VAC,1φ,50/60 Hz,1.5-hp,10A Weight Open Drive Model: 160-lbs - 48-in3 filter drier cores FD-048-CR Shipping: 210-lbs Compressor fluid, 1 gal OIL-POE-1G Connections: 3/4-in male flare 440 and 880 lb recovery tanks fittings with ball valves with 3/4 in. ports Tank float safety cables and Warranty 1-year Parts adapters Dimensions (L x W x H) Electromechanical 23 x 27 x 34 722

HANDIVAC HIGH CAPACITY OIL-LESS RECOVERY SYSTEM Extra condensing capacity and higher horsepower for faster refrigerant transfer rates and longer component life. High ARI Certified Recovery Rates (R-22) SPEED ENHANCING FEATURES Dual 0.75 hp oil-less compressors double recovery rates for servicing commercial cooling units. Unit self-evacuates prior to performing recovery. Compressor pulls directly on liquid with safeties to protect against slugging. LESS MAINTENANCE Oil-free compressor lessens maintenance hassles. Easily switches between R-12, R-22, R-134a, R-500, R-502, R-409, R-410a, MP39 and other high pressure refrigerants and blends. Dual fans provide abundant air flow to properly cool the compressor motor & head as well as other internal components for longer service life. SAFETY FEATURES High head pressure shut off at 425-psi. Low pressure shut off at 15-in Hg. Operational 80% tank full float valve shut off. push/pull* direct liquid vapor RTO-500 25-lb/min 7.8-lb/min 0.62-lb/min * Push/pull rates using 3/8-in. hose. Included with Purchase: 3/8-in. male flare x 3/8-in. female flare 6-ft float cable and 3 pin (BH) connector RFD154 FVC-006 Spare filter driers: FD-003-25 -In-line filter 3 in3,1/4 in. flare -3/8-in. male flare x 3/8-in. female flare RFD154 5, 10 and 20 ft x ¼ in. hoses 30, 50, 250 and 1,000 lb recover tanks Push/Pull (R-22)* 25-lb/min Direct Liquid (R-22) 7.8-lb/min Vapor (R-22) 0.62-lb/min Weight 63-lbs (28.6 kg) Motor 1.5 Hp Connections 3/8-in. Flare Dimensions (L x W x H) 18 x 10 x 16 Float Connection 3-pin BH Low-Pressure Switch15 Hg *Push/pull rates using 3/8 in. lines. 723

MITYVAC LIGHTWEIGHT OPEN DRIVE RECOVERY SYSTEM Offers the additional speed and durability of an open drive compressor in a lightweight package. ACCELERATES RECOVERY PROCEDURES TO SAVE LABOR AND REDUCE COOLING SYSTEM DOWNTIME 2.0-hp compressor moves refrigerant through a 1/2 port and valving system at sizzling rates of 55-lb/min liquid and 1.56-lb/min vapor (R- 22). High capacity air cooled condenser with 700-cfm fan maintains recovery rates at high ambient temperatures. RUGGED DESIGN OFFERS LONGER SERVICE LIFE AND GREATER FLEXIBILITY Open drive compressor is virtually impervious to the acids and contaminants that burnout hermetic or oil-less compressors. Services R-12, R-22, R-500, R-502, R-134a, MP39, R-409a, R-507 and other high pressure refrigerants and blends. Can be reprogrammed to service newly introduced refrigerants. SIMPLE OPERATING PROCEDURES Purging lines and switching from liquid to vapor recovery modes simply involves turning three 3-way hand valves no switching hoses is necessary. Included with Purchase (HOSES NOT INCLUDED): 50 ft. power cord Two in-line 30-in 3 filter driers FD-030-50 Recovery hoses - four required: 1/2 in. x 10 ft. hoses 050-010-HP-FB 050-020-HP- 1/2 in. x 20 ft. hoses FB Spare filter driers FD-030-50 Recovery tanks (float valves optional) -1000-lb capacity CYL-0250 Tank float safety cables and CYL-1000 adapters Liquid Push/Pull (R-22): 55 lb/min Vapor Rate (R-22): 1.56 lb/min Final Vacuum: 15 in. Hg Weight: 145 lbs. (180 shipping) Motor: 2.0 Hp Connections: 1/2 in. Flare Dimensions: (L x W x H) 18 in. x 14 in. x 19 in. (46 cm x 35 cm x 48 cm) 724

RECOVERY CYLINDERS Standard recovery tanks have small diameter ports that restrict refrigerant flow and slow your recovery procedures. Carrier 1000-lb and 250-lb tanks have been fitted with full port 3/4 service valves and copper dip tubes that eliminate restrictions and enhance throughput for faster recovery. Available in 30 lb, 50 lb, 250 lb, and 1000 lb capacities. Customer ASME vessels exceeding 1000 lbs and with larger ports are also available. Part No Description PORT SIZE DRY WEIGHT DIMS (ODXH) CYL-1000 1000 lb Tank only 3/4 358 lbs 30 x58 CYL-1000-LS 1000 lb w/80% shut off switch 3/4 359 lbs 30 x58 CYL-0250 250 lb Tank only 3/4 86 lbs 15 x49 CYL-0250-LS 250 lb w/80% shut off switch 3/4 87 lbs 15 x49 ASME CYLINDERS ASME Tank Features Mounted on casters Dual pressure relief valves Pressure gauge Liquid level indicator 80% tank full float switch Bottom drain connection Liquid and vapor ports ASME250 ASME500 Water Capacity 250 gal 500 gal Dry Weight 650 lbs 1,200 lbs Length (A) 94 in. 113 in. Diameter (B) 30 in. 37 in. Height (C) 42 in. 49 in. FLOAT VALVE CABLE Refrigerant Capacity at 80% Full ASME250 ASME500 R-12 2,195 lbs 4,390 lbs R-22 2,000 lbs 4,000 lbs R-134a 2,105 lbs 4,030 lbs R-500 2,034 lbs 4,068 lbs R-11 2,459 lbs 4,929 lbs R-123 2,440 lbs 4,880 lbs Part No FVC-006 FVC-012 Description 6-ft. Cable and connector for 80% shut off switches on Cylinders 12-ft. Cable and connector for 80% shut off switches on Cylinders 725

RECOVERY HOSES MANIFOLDS Part No Description HOSE SIZE 025-010-HP-FB 1/4 x 10 ft, flare w/ball valves 1/4 inch 025-020-HP-FB 1/4 x 20 ft, flare w/ball valves 1/4 inch 025-010-HP 1/4 x 10 ft, no isolation 1/4 inch 025-020-HP 1/4 x 20 ft, no isolation 1/4 inch 038-010-HP-FB 3/8 x 10 ft, flare w/ball valves 3/8 inch 038-020-HP-FB 3/8 x 20 ft, flare w/ball valves 3/8 inch 038-010-HP 3/8 x 10 ft, no isolation 3/8 inch 038-020-HP 3/8 x 20 ft, no isolation 3/8 inch 050-010-HP-FB 1/2 x 10 ft, flare w/ball valves 1/2 inch 050-020-HP-FB 1/2 x 20 ft, flare w/ball valves 1/2 inch 050-010-HP 1/2 x 10 ft, no isolation 1/2 inch 050-020-HP 1/2 x 20 ft, no isolation 1/2 inch 075-010-HP-FB 3/4 x 10 ft, hi pressure, flare w/ball 3/4 inch 075-010-HP-QC 3/4 x 10 ft, hi pressure quick connect 3/4 inch 075-020-HP-FB 3/4 x 20 ft, hi pressure, flare w/ball 3/4 inch 075-020-HP-QC 3/4 x 20 ft, hi pressure, quick connect 3/4 inch Manifolds allow recovery operator to transfer refrigerant simultaneously to multiple tanks or to pull vapor or liquid from multiple pickup points on the cooling system for faster speed. Part No RM-075-6 RM-050-6 Description 3/4 connections, 6 valves 1/2 connections, 6 valves 726

ENVIROPURGE HIGH PERFORMANCE PURGE SYSTEM Fast, reliable purging for low-pressure chillers.the Enviro-Purge system removes air and other noncondensibles from low pressure centrifugal chillers while minimizing the loss of refrigerant that normally accompanies the purging process. Purging is fast and microprocessor-controlled to match each chiller s requirements, and to provide historical data for studying purge trends and troubleshooting. Fast, efficient, noncondensible separation Nearly twice the evaporator coil surface area of typical purge units means fast, efficient refrigerant separation. Easy, hassle-free installation Ships pre-assembled and connects to existing ports on all types of chillers. Mounts conveniently near floor level. Simple operation Application-specific microprocessor controls enhance purge capabilities and provide a user-friendly software interface. High reliability, low maintenance Prefilter drier system removes moisture and debris from refrigerant before it enters the purge vessel. Stainless steel construction further protects the purge tank against corrosion. Safeguards Refrigerant Four temperature sensors monitor and control purge operations; alarms alert operator to trouble conditions so refrigerant loss can be avoided. Display can be in F or C. RAPID NONCONDENSIBLE SEPARATION The 1/3-hp condensing unit and oversized 350-cu.-in. purge vessel combine to process more refrigerant vapor faster. A patented reheat/re-expansion circuit provides maximum separation efficiency, and Enviro-Purge discharges only 0.48 lb. of refrigerant per pound of noncondensibles, or just 0.0049 lb when the optional carbon canister is used. CONSERVES REFRIGERANT Enviro-Purge s microprocessor control improves purge efficiency and prevents refrigerant loss, using multiple safeguards against false purging. Four temperature sensors provide continuous monitoring of purge operating conditions in either F or C. When excessive purging is detected, the LCD alerts the operator to increasing chiller leaks. CONVENIENT REMOTE INTERFACE Built-in RS-232-C interface allows energy management systems or any remote PC to monitor and control purge operations. Part No Description REFRIG EMS611-011 110 VAC, 50/60 Hz, 1φ, 15A 11 EMS522-011 220 VAC, 50 Hz, 1φ, 15A 11 EMS611-113 110 VAC, 50/60 Hz, 1φ, 15A 113 EMS522-113 220 VAC, 50 Hz, 1φ, 15A 113 EMS611-114 110 VAC, 50/60 Hz, 1φ, 15A 114 EMS522-114 220 VAC, 50 Hz, 1φ, 15A 114 EMS522-123 220 VAC, 50/60 Hz, 1φ, 15A 123 EMS611-123 110 VAC, 50/60 Hz, 1φ, 15A 123 CARBCAN Carbon canister -- Weight 175 lbs. Shipping 210 Approximate Dimensions 36 in. x 25 in. x 30 in. Condensing Unit Refrigerant R-134a Safety Certification ETL listed to UL, CSA and CE safety standards. 727

MINIPURGE PORTABLE HIGH AND LOW PRESSURE PURGE UNIT During normal operation the unit continuously displays and scrolls several system temperatures plus the current total pumpout time and cycle count.eliminate air from high or low pressure cooling systems to improve cooling efficiency and reduce energy costs. UNIVERSAL COMPATIBILITY Eliminates air from either high or low pressure refrigerants. Simply evacuate the unit before using on different refrigerant types. HIGHLY PORTABLE Smallest and lightest purge unit on the market. At 65-lbs in weight, it is readily hand carried. FAST PURGE SPEED Oil-less transfer compressor accelerates the purge process by pulling vapor from the cooling system and forcing processed refrigerant liquid back into the cooling system. HIGHER EFFICIENCY FOR BETTER REFRIGERANT CONTAINMENT Vapor is pumped through a high capacity condenser then compressed in a purge vessel. Microprocessor controls calculate the most efficient time to purge noncondensibles. Achieves discharge efficiency as high as 0.2 lb-refg/lb-noncondensibles on some refrigerants. Three to four times more efficient than thermal purge units on the market. Part No Description FD-003-25 1/4 in. flare in-line filters 025-010-HP-FB Refrigerant Hoses: 1/4 x 10-ft with ball valves 025-020-HP-FB Refrigerant Hoses: 1/4 x 20-ft with ball valves Connections 3/8 in. flares Dimensions (L x W x H) 18 in. x 10 in. x 16 in. (35 cm x 35 cm x 35 cm) Weight 65 lb Operating Environment 32-120 F, 5-95% RH, noncondensing Storage Environment (-40)-150 F, 5-95% RH, noncondensing Warranty 1-year parts 728