FRIGID COIL COPPER TUBE EVAPORATIVE CONDENSERS YEC Series

Similar documents
JCseries EVAPORATIVE CONDENSER. engineering data

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

KCC Centrifugal Fan Air Cooled Condensers

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

XLP2 Evaporative Condensers

Maximum Capacity and Highest Quality to the. Lowest Shipping Costs! Engineered to Deliver the. Worldwide Market - with the.

Advance Release September 2009

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Direct Fired Heater Model AD Specification

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

MAC N-407 Air-Cooled Chiller

13 GEP A L P - 1 A

C13-Series Engineering Guide

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Efficient, Long Lasting Evaporative Condensers

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

MAC-120HE-03 Air-Cooled Chiller

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

Product Introduction...E35. Benefits...E37. Construction Details...E39. Custom Features & Options...E41. Accessories...E44. Engineering Data...

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL FEATURING

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

VertiCool Aurora Engineering Guide

MACH N-407 Heat Pump Air-Cooled Chiller

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

Split System Heat Pumps

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

technical guide Water-Cooled Self-Contained Units

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

50Hz AC, HP and Air Handler Units Up to 70 kw. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

RGE 13 A T - 1 A

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Modular Supply Make-Up Air Unit

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

1.1 This section applies to air handling units for HVAC Systems.

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Evaporative Cooling products

Direct Gas-Fired Make-Up Air

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.

RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

AIR HANDLER SPECIFICATION

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

Engineering Specifications for HXV Closed Circuit Hybrid Cooling Tower

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

PACKAGE AIR CONDITIONER

Evaporative Condensers

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

LSFG-8 LOW SOUND & SLSFG-10 SUPER LOW SOUND TOWER FEATURES

Indirect Gas-Fired Make-Up Air

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

How about Savings in Time, Money, Energy and Longer Life?

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

SECTION COOLING TOWERS

SECTION AIR-COOLED SPLIT SYSTEM AIR CONDITIONING UNITS

EMI ENGINEERING SUBMITTAL

Maintain. a TOWER of POWER. Part One How to. Don t let out of site, out of mind prevent you from keeping cooling towers running efficiently

SMALL AIR COOLED CONDENSERS

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

SKYPAK II, 3 Ton Series, gives you a

Closed Circuit Coolers Technology for the Future, Available Today

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

VTL Open Cooling Towers... B98. Benefits... B100. Construction Details... B102. Custom Features and Options... B103. Accessories...

EMI ENGINEERING SUBMITTAL

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

SKYPAK II, 3 Ton Series, gives you a

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

Closed Circuit Cooling Towers

SECTION AIR COMPRESSORS AND ACCESSORIES

SECTION AIR COOLED WATER CHILLERS

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

Transcription:

Form 60.-SED (SEP 04) Replaces: E0- SED (SEP 04) FRIGID COIL COPPER TUBE EVAPORATIVE CONDENSERS YEC Series Please check www.johnsoncontrols.com for the latest version of this publication.

60.-SED (SEP 04) Page 2 YEC SERIES COPPER TUBE EVAPORATIVE CONDENSERS

YEC SERIES COPPER TUBE EVAPORATIVE CONDENSERS 60.-SED (SEP 04) Page CONTENTS ALL YEC SERIES EVAPORATIVE CONDENSERS HAVE COPPER TUBING...4 CHOOSE COPPER...4 SAFETY and DURABILITY...4 SERVICE ACCESS DETERMINES MAINTENANCE COST...4 LONGEVITY...4 WHERE TO FIND US... In-store Retail Market... Beverage Distributing Facility... HVAC... Office Building... SPECIAL POINTS...6 BUILT IN BASICS...6 ACCESS DOOR...6 CABINET...6 SPRAY PUMP...6 DRIFT ELIMINATORS...6 SUMP BASIN...6 FORCED DRAFT BLOWER...6 BLOWER MOTOR AND DRIVES...6 INDIVIDUAL CONTROL OPTIONS...7 CRITICAL PROTECTION PACKAGES (CPP)...8 SELECTION PROCEDURES...9 YEC SERIES EVAPORATIVE CONDENSERS CAPACITY DATA... MULTICIRCUITED CONDENSER COIL DESIGN CRITERIA... PHYSICAL DATA... OPERATIONAL DATA...

60.-SED (SEP 04) Page 4 YEC SERIES COPPER TUBE EVAPORATIVE CONDENSERS ALL YEC SERIES EVAPORATIVE CONDENSERS HAVE COPPER TUBING Smart managers earn extra years of trouble-free operation by choosing Copper Tube coil construction. CHOOSE COPPER Noncorrosive Copper tubing is classified as noncorrosive. This means more years of productivity and trouble-free operation. Copper tubing provides a clean interior surface for your process fl uid system. Corrosion resistance means long service life. Efficient Heat Transfer Copper is the most effi cient heat transfer material available for evaporative condensers. This allows smaller units and lower energy consumption to produce the required heat transfer. Design Flexibility Copper coil can be split into a large number of independent circuits to handle diverse applications and confi guration requirements. Supermarkets often require multiple condensing circuits that function independently to match the confi guration of refrigeration systems. The circuits must maintain a variety of products, from ice cream to produce, at different condensing temperatures. Light Weight...Economical Installation Copper is a light weight material. It yields a more compact design that delivers results similar to other units using steel as the coil construction material. Less weight also means less required support structure and lower installation lifting costs. CRITICAL HEAT TRANSFER POINT Condensing Effectiveness Determines System Efficiency. If the condensing process is not functioning at the optimum level, the overall system costs more to operate. Why? The system works harder to achieve the same result. SERVICE ACCESS DETERMINES MAINTENANCE COST Don t waste time trying to get to the equipment. Johnson Controls evaporative condensers provide easy access for maintenance. This means less hours invested by your maintenance team to keep equipment in prime condition and lower cost for your bottom line. SAFETY and DURABILITY Prevent leaks and make your investment last. Welded stainless steel sumps are superior. Welded closures are permanent. They are secure and eliminate the water leaks that develop over time with fl anged and gasketed construction. No water, no rust, no bacteria or standing water in your equipment room. This also provides a safety bonus by removing hazards for your operators working near electrical wiring. LONGEVITY Stainless steel can also be used for Johnson Controls upper cabinet construction. If you have adverse water conditions in your facility (i.e. heavy water, chlorine, low ph, or alkaline conditions), stainless construction is for you. Stainless steel resists corrosion and provides many additional years of service. Standard construction is galvanized.

YEC SERIES COPPER TUBE EVAPORATIVE CONDENSERS 60.-SED (SEP 04) Page WHERE TO FIND US In-store Retail Market The mechanical systems in supermarkets are designed to provide cooling for multiple walk-in boxes, refrigerated cases, and specialty fi xtures that commonly operate with different refrigerants and at different temperatures. Johnson Controls effectively and efficiently rejects heat into the atmosphere from your facility refrigeration load. The use of a copper condenser coil allows for fl exible multiple circuiting with headers external to the unit casing. This is the easiest way to accommodate the individual needs of each separate condensing circuit. Supermarkets are often located next to neighborhood businesses and residences. The selection of an indoor condenser will eliminate the sound generated from a conventional outdoor installation and make the facility more acceptable to the location. Sightlines are enhanced also by locating the unit indoors rather than on the roof top. The YEC copper tube condenser incorporates a forced-draft centrifugal fan design. The moist discharge air is ducted to the outdoors. As a result, the fan operates in a relatively dry entering-air stream and avoids corrosion from moist air in the condenser. Our forced draft blower design means the condenser may be located indoors as well as outside, improving facility aesthetics while it reduces noise. Because the energy required to keep both products and customers cool is, by far, the greatest portion of the overall energy consumption for a typical supermarket, it makes sense to choose a condenser to deliver the maximum in heat transfer effi ciency and the YEC can help you control costs. Beverage Distributing Facility Facilities such as these primarily use halocarbon refrigerants for relatively highertemperature applications and are well-suited to copper tube evaporative condenser design. These systems are frequently sized to handle the infrequent pull-down loads associated with bringing warm product into the facility. This makes the use of the centrifugal fan design with optional pony motor especially desirable once the bottles or cans are in storage and the loads are reduced. HVAC Johnson Controls copper evaporative condensers are available in sizes ranging from to 62 tons nominal. This means there is a model for almost every air conditioning system, no matter how large or how small! Although airconditioning applications are typically not as stringent as those involving product refrigeration, these systems are frequently required to operate over a wide range of ambient outdoor temperatures. By providing a thermostatically operated fan damper control package, Johnson Controls ensures that expansion devices will be furnished with a reliable supply of liquid refrigerant, day or night. Office Building The Johnson Controls YEC has a compact, forced-draft blower design that allows indoor installation. This makes it a desireable solution to satisfy architectural considerations. Our standard construction design and quality prehandles many of the issues that relieve the facility manager of troublesome maintenance and service issues. Optional features offered in our plus packages offer enhanced service that can add additional years of smooth operation. This equals peace of mind and one less worry for the property manager!

60.-SED (SEP 04) Page 6 YEC SERIES COPPER TUBE EVAPORATIVE CONDENSERS SPECIAL POINTS ACCESS DOOR DRIFT ELIMINATORS FORCED DRAFT BLOWER CABINET SUMP BASIN SPRAY PUMP BLOWER MOTOR AND DRIVES BUILT IN BASICS All of the standards you expect, and more. Cabinet Our standard construction is galvanized steel, fl anged and gasketed to provide a watertight enclosure. All internal condensing coil support framing is constructed of stainless steel to avoid corrosion. the potential for clogging. Spray headers have easy-toremove end caps located outside unit casing to facilitate service. Spray pump motors are available as either 8 or 20-460-volt, 60 cycle, phase. Consult factory for alternate voltage or cycle characteristics. Access Doors Gasketed, oversized stainless steel access doors are made for easy entry to clean the sump basin. Quick-acting latches mean superior serviceability and ensure a watertight fi t. Sump Basin Say goodbye to leaks with welded stainless steel construction. Pan includes stainless steel drain connection with removable plastic overfl ow standpipe installed. Overfl ow standpipe is easy to remove by hand and makes draining the sump pan for cleaning a snap. Condensing Coil Assembly Copper tubes (/8 OD) and return bends with silver brazed joints. Tubes are supported by rugged CPVC-insert tube sheets. All condensing coils are tested under water at 0 psig to ensure leak-free operation. Spray System Spray water system consists of a closecoupled centrifugal spray pump that draws water from the sump basin and distributes it over the entire condensing coil assembly. Spray headers and nozzles are durable ABS plastic and the nozzles incorporate large orifi ces to reduce Figure - Condensing Coil Assembly Blower Forward-curved centrifugal blower is constructed of galvanized steel. Wheels are balanced after unit assembly to enhance smooth operation. Blower wheels are keyed to a polished, precision-ground, solid steel shaft. Wheels are supported by rugged, prelubricated, self-aligning bearings, specially selected for long service life.

YEC SERIES COPPER TUBE EVAPORATIVE CONDENSERS 60.-SED (SEP 04) Page 7 On-line Service Our optional external fl oat assembly provides an external fl oat chamber. It houses the solid brass fl oat valve and arm outside of the turbulent basin water and fan discharge airstream. As a result, the fl oat assembly can be serviced without shutting down the unit. Figure 2 - Spray System Blower Motors and Drives 00 RPM motors with. service factor are standard. Available as 8 or 20-460 volt, 60 cycle phase. Consult factory for alternate voltage or cycle characteristics. All motors undergo complete factory run-testing prior to shipping. Drive pulleys and V-belts are conservatively selected to provide continuous, trouble-free service. Motors mounted on heavy-duty adjustable base to allow for fan belt tension adjustment. Drift Eliminators Shipped in lightweight, easily removable sections constructed from corrosion-resistant polyvinyl-chloride (PVC). Effi cient design ensures removal of entrained water droplets from the leaving air stream, limiting drift rate to 0.002% of recirculating water rate. Bleed Control Factory calibrated automatic bleed trough minimizes scaling without excessive water loss. Water Makeup System The water makeup system is comprised of a solid brass fl oat valve and arm. Stainless steel baffl es surround the fl oat ball on three sides to isolate the fl oat. This prevents the ball from being bounced by internal air stream turbulence and gives stable operation. Extended lube lines Run from bearing to outside of the fan guard. With this easy access position, the fan guard can be left in place during service. Just place grease gun against fi tting and squirt. INDIVIDUAL CONTROL OPTIONS Long Life Stainless Steel is recognized as corrosion resistant, lasting longer than most other construction materials. Use it for your unit casings to ensure extended service life. Select Stainless Steel for the Blower Scroll. Inlet venturis and bearing supports are fabricated from epoxy-coated galvanized steel. Blower guards may be constructed from stainless if desired. Access Means Serviceability A Johnson Controls exclusive, our optional extra access door is available for cabinet sizes through (single door is standard). Make it safe and easy for your service team and minimize costs as well. Dampers for Simple Temperature Management Dampers are for less sophisticated applications. They are perfect for environments with relatively constant condensing temperature over a range of ambient operating temperatures. A thermostatically controlled damper motor modulates a damper in response to sump water temperature. An integral end switch, located within the damper motor, may be adjusted to cycle the blower motor off when the damper fully closes and on with subsequent temperature rise. Lower Energy Usage Reduce your capacity requirements with a secondary pony motor. Its reduced horsepower can operate the blower at a reduced speed during periods of lower ambient temperatures or standby conditions, leaving your primary motor on idle. Lower energy usage means lower costs. Pony motor is mounted with its own pulleys and V-belts on a common shaft with the primary blower motor. The pony motor is generally sized to provide 0% of full airfl ow. The horsepower is consistent with established fan laws. Consult factory to obtain horsepower requirements for alternate airfl ow reductions. Handle Higher Static Pressure For applications that exceed the function of our standard units (up to /4" of external static pressure), the factory can resize blower drives to compensate for additional static pressure up to /2". Motors for Special Needs TEFC, Severe-Duty TEFC, Explosion-Proof, Multi-Speed, and Energy-Effi cient (Super E) motors are available to meet your specifi cations. No Fuss Motor Control Make work simple with our optional electric motor control panel. Installed on your unit and factory prewired to the blower motor and spray pump, the panel includes a NEMA-R duty enclosure, main disconnect switch, control circuit fusing, and transformer, as required. Service personnel have convenient access to fuses and starters for the blower, spray pump motors, and toggle-type control circuit switches are also installed on the face of the enclosure. Optional NEMA- and NEMA-4 enclosures are available. Freeze Protection Protect your sump water from freezing during low-ambient operation. Order a factory-installed, electric immersion heater (single or three-phase), control thermostat, and low-water-level cutout switch. This is protection you will be glad to have. Prevent Heat Loss Don t lose water heat during shutdown. The positive-closure damper option mounts on its own discharge hood. It is factory installed on the top of smaller-sized equipment, shipped loose for larger units. Johnson Controls recommends a single layer of closed-cell rubber foam, applied to the exterior of the unit casing with positive-closure damper option applications. Reduce Debris Keep unwanted debris and contaminants out of your system with a stainless steel screen-type pump inlet strainer.

60.-SED (SEP 04) Page 8 YEC SERIES COPPER TUBE EVAPORATIVE CONDENSERS SELECTION PROCEDURES EVAPORATOR TON METHOD The Evaporator Ton selection method uses the fact that the evaporative condenser model numbers represent a nominal tonnage of evaporator capacity. The method should NOT be used in conjunction with the Total Heat Rejection figures of Table 4. The Evaporator Ton selection method should only be used on systems utilizing open reciprocating compressors. The selection method is based on average horsepower requirements for open reciprocating compressors and cannot be considered as precise. Critical selections of this type should be checked by the Heat-Of-Rejection Method. SELECTION PROCEDURE. Determine the evaporator capacity in tons of refrigeration (one ton,000 BTUH). 2. Determine Design conditions (condensing temperature, suction temperature and wet bulb temperature).. Using Table, find the correction factor for condensing temperature and wet bulb temperature, and from Table 2 the correction factor for suction temperature. 4. Multiply evaporator capacity from Step. by correction factors from Step.. From Table 4 select the evaporative condenser whose model number equals or exceeds the corrected evaporator capacity calculated in Step 4. SELECTION EAMPLE (Open reciprocating compressors only) GIVEN: R-22 Refrigerant Evaporator Capacity 62 tons Suction Temperature +0 F Condensing Temperature F Wet Bulb Temperature 72 F SOLUTION:. Determine the capacity factor for R-22 at F condensing temperature and 72 F Wet Bulb Temperature from Table 2. Determine the suction temperature correction factor for 0 F from Table 2.0. Multiply 62 x x.0 4.9 corrected tons. 4. From Table 4 select a unit equal to or larger, in this case YEC -7. TABLE CONDENSER CAPACITY FACTORS / Refrigerant R-4A, R-22, R-4A & R-07 Cond. Temp. ( F) 8 9 0 0 Entering Air Wet Bulb Temperature ( F) 0 60 6 68 70 72 7 78 80 8.0..78.6.7.6.98.8.7.66.60.4...9.8.6.7.6..04.88.76.67.60..87.4..9.79.6..98.4..97.8.72.64.6 2.26.72..0.7.66.8 2.80.96.9..9.80.69.60 2..9.22.00.8.7.6 2.7.2.0.89.7.6 2.0.27.02.84 2..67.26.99.8 TABLE 2 SUCTION TEMPERATURE CORRECTION FACTOR Suction Temp ( F) Capacity Factor -.2 -.2 0.7 +. +.07 +0.0 +.00 +0 0.97 HEAT OF REJECTION METHOD In a mechanical refrigeration system, the heat to be rejected by the evaporative condenser is equal to the heat input at the evaporator plus the energy input at the compressor. Therefore, in order to accurately determine the proper evaporative condenser required, it is necessary to establish the compressor energy input as well as the heat absorbed in the evaporator. For open compressors: Total heat of rejection Compressor evaporator capacity BTUH + (Compressor BHP x ) For hermetic compressors: Total heat of rejection Compressor evaporator capacity BTUH + (Compressor KW x 4) SELECTION PROCEDURE. Establish total Heat Rejection required by the system. 2. Determine the Design Conditions (condensing temperature, suction temperature and wet bulb temperature).. Determine the correction factor to be used from Table based on condensing temperature and wet bulb temperature. 4. Multiply correction factor by the total system heat of rejection.. Select the condenser from Table 4 whose base heat rejection equals or exceeds the corrected heat rejection from Step 4. SELECTION EAMPLES GIVEN: R-22 Refrigerant, hermetic reciprocating compressor Compressor evaporator capacity 62 tons Compressor KW input 4 Condensing Temperature F Wet Bulb Temperature 72 F SOLUTION:. Determine the Heat Rejection Compressor evaporator capacity 62 x,000 744,000 Compressor KW Input 4 x,4,67 Total Heat Rejection 897,67 2. Determine the Heat Rejection capacity factor for R-22 at F condensing temperature and 72 wet bulb temperature from Table, which is.. Multiply 897,67 x 772,000 BTUH 4. From Table 4 select a unit with a base total heat rejection equal or greater than 772 MBH. In this case, select a YEC -7 with a Heat Rejection rating of 87.9 MBH. TABLE HEAT REJECTION CORRECTION FACTORS/REFRIGERANTS R-4A, R-22, R-4A, R-07 Cond. Temp. ( F) 8 9 0 0 Entering Air Wet Bulb Temperature ( F) 0 60 6 68 70 72 7 78 80 8..9.80.7.6.6.22.02.87.76.66.9.2.9.4.9.82.62..67.2.08.89.76.66.8..94.47.6.9.79.60. 2..9.22.98.8.7.62.4 2.4.7.2.0.7.64. 2.94 2.00.4..9.79.67.7 2.8.6.2.00.84.60 2.78.79..0.88.7.62 2.6.72.27.0.8.68 2.0.6.9.92.7

YEC SERIES COPPER TUBE EVAPORATIVE CONDENSERS 60.-SED (SEP 04) Page 9 TABLE 4 YEC SERIES EVAPORATIVE CONDENSERS CAPACITY DATA YEC Evaporator Total Heat* Model Nominal Total Heat* No. of Rejection No. Tons* Rejection Circuits per Circuit - 47,000 9 7,77-2,00 9,60-4,000 9,474 2-2 2 67,00 2 7,00 2-0 0 44,000 2 2,000 2-4,00 2,00-88,000 26 22,6-46 46 676,0 26 26,008-749,700 26,8-7 7 87,0 26 2,227 4-64 64 9,800, 4-7 7,07,0 2, 4-80 80,76,000,66 -,2,000 4 2,268-0 0,470,000 4,84 -,67,000 4 9,49 -,778,700 4 4,8 * Standard Capacity for 78 W.B., F Suction, Condensing with Refrigerants R-4A, R-22, R-4A, R-07. Consult Factory for Ratings with Alternate Refrigerants YEC Evaporator Total Heat* No. of Total Heat* Model Nominal Rejection Circuits Rejection No. Tons* per Circuit 6-,984,00 0 9,6 6-2,,000 0 44,0 6-6 6 2,42,00 0 48, 6-0 0 2,646,000 0 2,9 6-0 0 2,9,000 0 8,800 7-2 2,,000 70 0,0 7-272 272,998,000 70 7,4 7-4,,000 70 9,87 8-4,704,000 70 67,0 8-0 0,4,000 70 7,00 9-7 7,,00 76 72, 9-0 0,880,000 76 77,68-42 42 6,7,00 76 82,4-40 40 6,6,000 76 87,09-47 47 6,982,00 76 9,87-2 2 7,77,00 76,46-60 60 8,22,000 76 8,6-62 62 9,7,00 76 0,888 MULTICIRCUITED CONDENSER COIL DESIGN CRITERIA The Johnson Controls YEC, Evaporative Condenser can be furnished from the factory with individual refrigerant circuits for applications where a multiple of refrigeration systems are connected to a single unit. The procedure for selecting a multicircuited condenser is described in the Selection Example as outlined. For circuit identification purposes it is required that the circuits be arranged in numerical sequence. The connections will be numbered at the factory in this sequence, from left to right, with no. circuit being on the extreme left. SELECTION EAMPLE GIVEN: Condensing Temperature F Wet Bulb Temperature 72 F Five individual suction cooled hermetic compressors operating at suction temperatures and capacities as shown in the tabulation below. (Table 6) PROCEDURE. Tabulate data in Columns, 2, and making sure circuits are in correct numerical sequence. 2. From Table, select the Evaporator Temperature Capacity Factor applicable to each suction temperature listed in column 2, and enter in column 4.. From Table select Heat Rejection Capacity Factor applicable to the design condensing temperature and the design wet bulb temperature, and enter in Column. 4. Multiply figures in Columns, 4 and and enter in Column 6.. Add all the capacities in Column 6 to arrive at the Total Heat Rejection (BTUH) required and use the total to select the proper size condenser from Table 4. SELECTION: 6. The Total Heat of Rejection for the five refrigeration systems adds up to 8,747. Table 4 shows that the smallest condenser that will meet the requirement is a model YEC 2-2 with a Total Heat Rejection of 67,00 BTUH. 7. Enter the capacity per circuit from Table 4 in Column 7. Divide Column 6 by Column 7 to get the number of tubes required and enter in column 8. 8. To assign the circuits properly, round the number in Column 8 to the nearest whole circuit and enter in Column 9. Each system must have a minimum of whole circuit assigned to it. NOTE: If the total number of circuits assigned are more or less than available on that unit, and no spares are desired, add or subtract circuits to effect a balance. However, if a reduction causes more than % reduction in any of the systems capacities, go to the next larger size unit and reassign tube circuits to give adequate capacity to every circuit. TABLE EVAPORATOR TEMPERATURE CORRECTION FACTORS Evap. Temp. F. Open compressors Hermetic Compressors -0.80 2. -2 - - - - 0 2 0.72.6.9..98.74.6.49.4..6..7..46.42.8.0..26..22.4.2.0.27.2 TABLE 6 MULTICIRCUIT DESIGN CRITERIA 2 4 6 7 8 9 CIRC. NO. 2 4 EVAP. TEMP. - - +0 + + COMP. CAP. BTUH 22,00,9 64,000 0,000 64,000 TABLE.6.7.0.2.42 TABLE THR @ 78,, 48,00 7,0 9,000 78,7 CAPACITY PER CIRCUIT FROM TABLE 4 7,00 7,00 7,00 7,00 7,00 NUMBER CIRCUITS REQUIRED.80 2.77 4.08 7.7 4.47 NUMBER CIRCUITS ASSIGNED 2 4 7 Total 8,747 TOTAL CIRCUITS ASSIGNED: 2

60.-SED (SEP 04) Page YEC SERIES COPPER TUBE EVAPORATIVE CONDENSERS PHYSICAL DATA TABLE 7 Model No. A B C D E F G H L M N P Q R T U YEC - - - 2-2 2-0 2- - -46 - -7 4-64 4-7 4-80 - -0 - - 6-6- 6-6 6-0 6-0 7-2 7-272 7-8- 8-0 9-7 9-0 -42-40 -47-2 -60-62 80 80 80 8 8 8 6 6 6 6 6 94 94 94 2 2 22 22 27 27 9 9 4 4 4 4 4 4 7 2 7 2 7 2 7 2 46 4 46 4 46 4 6 4 6 4 6 4 6 4 9 9 9 9 9 6 2 6 2 6 2 6 6 6 68 68 68 7 4 7 4 7 4 7 4 8 4 8 4 8 4 8 4 8 4 2 2 2 27 27 27 4 4 4 4 42 42 42 2 2 2 2 6 4 6 4 6 4 6 4 6 4 88 4 88 4 88 4 88 4 88 4 47 4 47 4 47 4 6 6 6 6 76 4 76 4 76 4 92 92 92 92 9 9 9 9 6 6 7 7 2 2 44 4 44 4 44 4 0 0 0 62 62 62 62 7 4 7 4 7 4 89 89 89 89 6 6 6 6 60 60 4 4 8 8 2 2 2 22 22 22 2 2 2 4 4 4 4 8 8 8 8 8 60 60 60 6 6 9 9 9 9 9 9 9 9 9 4 4 2 4 2 4 4 2 4 2 4 2 2 4 2 2 2 2 2 2 2 4 2 2 4 2 2 4 2 2 4 4 4 2 4 4 2 2 2 4 27 4 4 42 4 8 4 8 4 4 4 4 4 4 4 4 7 7 49 4 4 4 49 2 4 64 9 4 64 9 4 64 9 4 64 9 4 9 9 9 9 9 9 9 22 22 7 7 7 7 7 7 2 2 2 2 2 2 2 2 2 2 2 2 2 8 8 8 2 8 2 8 2 8 2 8 2 8 2 8 2 8 8 8 8 8 8 8 8 8 8 8* 8* 8* 8* 8* 2 8 2 8 2 8 2 8 2 8 2 8 8 8 8 8 8 8 8 8 2 8 2 8 2 8 2 8 2 8 2 8 2 8 2 8 2 8 2 8* 2 8* 2 8* 2 8* 2 8* 2 8 2 8 2 8 2 8 2 8 2 8 8 8 * Models 7-2 thru 8-0 have two inlet and two outlet connections as standard. Models 9-7 thru -62 have four inlet and two outlet connections as standard.

YEC SERIES COPPER TUBE EVAPORATIVE CONDENSERS 60.-SED (SEP 04) Page OPERATIONAL DATA TABLE 8 YEC MODEL NO. YEC - - - 2-2 2-0 2- - -46 - -7 4-64 4-7 4-80 - -0 - - 6-6- 6-6 6-0 6-0 7-2 7-272 7-8- 8-0 9-7 9-0 -42-40 -47-2 -60-62 FAN MOTOR H.P. (2) 2 2 7 2 7 2 7 2 2 0 0 0 0 0 0 60 60 PUMP MOTOR H.P. 2 2 2 2 4 4 4 7 2 7 2 SPRAY AIR REFRIGERANT CHARGE (LB) WATER FLOW GPM CFM R-4A R-22 R-4A R-07 4 4 4 72 72 72 72 8 8 8 2 2 2 2 2 00 00 00 6 6 0 0 40 40 2,80 2,, 4,800, 4,800 7,0 8,000 8,40 8,00 9,600,00,000 7,0 7,000 9,800 9,0 26,00,800 2,700,00,00 7,0 6,600 9,000 48,000 47,000 6,40 9,000 66,0 68,0 7,000 78,000 79,000 8,0 2 7 4 7 66 78 88 8 0 2 4 9 8 9 20 9 08 8 4 40 08 4 2 607 7 666 679 788 78 9 894 8 2 7 0 6 6 77 86 8 99 0 4 7 92 226 4 0 2 9 42 00 482 98 64 6 668 776 772 896 880 22 27 4 4 48 66 74 7 84 0 9 4 7 64 9 268 0 2 6 427 4 4 482 60 7 66 660 766 72 87 27 4 4 48 66 74 7 8 9 4 7 64 94 268 260 0 62 4 4 44 48 6 72 664 66 767 7 87 SUMP HEATER KW ().0.0.0... 2.0 2.0 2.0 2.0 2.6 2.6 2.6 4.0 4.0 4.0 4.0.7.7.7.7.7 8.0 8.0 8.0.0.0.0.0 4.0 4.0 6.0 6.0.0.0 MIN. WALL APPROIMATE WEIGHT (LB) CLEARANCE (INCHES) SHIP OPER. 8 8 8 6 6 6 6 0 0 72 70 800.0,,0,,00,0,40,800,0,,0,0,60,800 4,0,0,,0,00 7,680 8,060 8,0 9,,000,00,000,0,000,0,00,42 4,2,0,070,,,680,780,80,0 2,0 2,080 2,6 2,8 2,870 4,460 4,7 4,984,60 6,80 7,0 7,0 7,40 7,70,6,9,00,000,00,0,7 7,000 7,600,70 9,40 2, 2,980. Design Specifications are subject to change without notice. 2. For higher static pressure use next size motor.. Optional item

60.-SED (SEP 04) Page YEC SERIES COPPER TUBE EVAPORATIVE CONDENSERS Protect Your New Equipment for Long Service Life Maintain Regularly CRITICAL PROTECTION PACKAGES (CPP) All Johnson Controls Evaporative Condensers are factory engineered to provide years of effi cient operation and service. Our standard design incorporates serviceability, innovations such as man-sized access doors with quick-acting latches, and extended lubrication lines for fan bearings. The following options packages are suggested as ways to optimize the lifetime and performance effi ciency of your heat transfer products. DURA-PLUS CPP Highly recommended for applications where more stringent durability requirements apply. Cabinet casing material is upgraded to stainless steel to match the standard sump basin and access doors. Virtually every water contact surface is fabricated of corrosion-resistant stainless steel. The top four rows of copper condensing coil are upgraded to a heavy-wall 0.049" thickness tubing specifi cation. Designed for refrigeration-duty applications involving higher compression ratios and corresponding superheat temperatures. A screen-type pump inlet strainer fabricated of stainless steel protects the spray pump from incoming debris. CONTROL-PLUS CPP When unit control is a priority, designed for applications. Factory prewiring Customer only has to make a single power wiring connection to the unit. Weather-resistant, UL-approved motor control panel is prewired. All motors are factory-wired to the control panel. Fan damper control package maintains a relatively constant process fl uid temperature over a range of ambient operating temperatures. Convenience outlet furnished in a weather-tight housing, affi xed to the outside of the control panel. Supplies power for customer s water treatment components or light-duty accessories such as service lights. SERVICE-PLUS CPP Put the focus on convenience. Makes service easier and more effi cient. Additional access door supplied for the smaller sized units (cabinets # through #). Dual sump drain confi guration allows for quick draining of the unit. Fan and pump operation are not interrupted. External fl oat chamber allows adjustment and service of the water makeup fl oat valve while the fan and pump are running. WEATHER-PLUS CPP This option is the best protection for installations in extreme, cold-weather climates. Electric immersion-style sump heater, single-phase or three-phase, offers freeze protection for sump water. Closed-cell foam insulation, affi xed to the outside of the cabinet and sump basin, holds the heat provided by the electric heater element within the unit. Positive-closure motorized damper is mounted atop a tapered discharge hood. Damper closes automatically when the unit is not operating. Maintains the correct minimum temperature within the unit for maximum protection against freezing process fl uid and consequential equipment damage. Ask your representative about the Critical Protection Package options. These groupings are exceptional values when added to the initial specifi cation. Form 60.-SED (4) Supersedes: E0- SED (4) Subject to change without notice Published in USA GUI 00 708. 08 Johnson Controls Inc. ALL RIGHTS RESERVED JOHNSON CONTROLS Dutch Road Dixon, IL 62 Phone: 8-8-89 FA: 8-8-66 www.johnsoncontrols.com