FFH Series. Steam Fired Instantaneous Feed Forward Water Heaters

Similar documents
Heat Transfer Packages

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

Water Heaters. Solar Applications

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

SEH Series. Stainless Steel Instantaneous Packaged Steam Fired Water Heaters

Cemline Steel Tanks. Carbon Steel, Stainless Steel, Galvanized Steel, Copper A.S.M.E. Code, Non-Code

SWH Series. STONESTEEL Packaged Copper Coil Water Heaters Steam/Boiler Water/High Temperature Hot Water Vertical or Horizontal

SPH Series. Vertical Packaged Storage Boiler Water Fired Plate Heat Exchanger Water Heaters CEMLINE CORPORATION

High Capacity Instantaneous Steam Fired Water Heater

USG Series. Unfired Steam Generators Generate Clean Steam With Boiler Steam or High Temperature Hot Water as the Energy Source

EHB Series. STONESTEEL Commercial Electric Water Heaters Individually Mounted Elements Vertical or Horizontal CEMLINE CORPORATION

Instant hot water Feed-Forward system unlimited supply accurate to +/- 4 F

Packaged Semi-Instantaneous Steam Fired Water Heater

UNFIRED STEAM GENERATORS STANDARD EQUIPMENT

Packaged Steam Fired Water Heater

Semi-Instantaneous Indirect Fired Water Heater

OPERATING AND MAINTENANCE MANUAL FOR INSTANTANEOUS STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL F

Tepid Water Delivery System

Flo-Rite-Temp Instantaneous Steam/Water Heater

Commercial Semi-Instantaneous Water Heaters

Flo-Rite-Temp Installation and Operation Manual IOM-780-N

Flo-Rite-Temp Instantaneous Steam/Water Heater

ASME Packaged Indirect Fired Water Heater

13-1. Temperature Regulator

Series 1140 and 1141 Temperature Regulators

PROVIDES TEPID WATER FOR EMERGENCY SHOWER

Installation, Operation, and Maintenance Manual CEMLINE CORPORATION

INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER. Compact Design. High Recovery. Energy Efficient. Stainless Alloy Construction

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

FLO-RITE-TEMP INSTANTANEOUS WATER HEATER INSTALLATION AND ADJUSTMENT INSTRUCTIONS FOR SINGLE AND DOUBLE WALL UNITS

DUKE UNIVERSITY DESIGN GUIDELINES

SECTION WATER HEATERS

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

Silhouette. Feedwater Heater. Boiler Feedwater

TECHNICAL. Series 18. Pump Packages

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

P-K COMPACT SEMI-INSTANTANEOUS INDIRECT WATER HEATERS

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

Packaged Instantaneous Circulation Heater Full KW Selection In All Voltages, Single or Three Phase

SECTION. Hot Water ARMSTRONG PRODUCT CATALOGUE

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

Operation & Maintenance Manual

Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water

HEAT GENERATION 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS. B. Section HVAC Basic Materials and Methods

Hydronic Product & Application Catalog

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer. Hot Water Inlet. Cold Water Inlet G3600LF

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

INSTALLATION AND MAINTENANCE INSTRUCTIONS. IM US March RediHeat. Table Of Contents. I. Installation RediHeat Start-Up Procedure 4

Blowdown Separator & Aftercoolers Installation, Operation, & Maintenance

University of Delaware

Installation & Operation Manual Models: TSU

SECTION PLUMBING EQUIPMENT

OUTLET HOT INLET COLD INLET INSTALLATION

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

INSTALLATION ADJUSTMENT SERVICE

Moss MOSS TRAY DEAERATOR ECONOMICAL INDUSTRIAL DEAERATOR SYSTEMS

Economical and simplified solutions that offer quality and optimum steam trap service.

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

Deaerator. Specifications

INTRODUCING THE BRADFORD WHITE 24/7 EXPERT SUPPORT CENTER. TABLE OF CONTENTS. Technical Support: Warranty Support:

Thermal Fluid Heaters

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

University of Houston Master Construction Specifications Insert Project Name SECTION DOMESTIC WATER HEATERS PART 1 - GENERAL

Armstrong Flo-H2O Water to Water Instantaneous Heater Installation and Maintenance & Operation

5 (34) 10 (69) 45 (170) 64 (242) 65 (246) 92 (348) 90 (341) 127 (481) 85 (322) (227) 80 (303) 113 (428) 148 (560) 105 (397) 141 (534) 100 (379)

Control and power circuit fusing to meet N.E.C.

Clean Steam Generators

ARTESIAN 220 & 340 Instantaneous Indirect Water Heater By Dunkirk Boilers INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL

MAXIMISER Semi-Storage Calorifiers

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

SECTION DOMESTIC WATER HEATERS

Commercial, Residential & Institutional Pumps, Tanks, & Accessories

TEMPERATURE CONTROLLERS

Steam Ancillary Equipment. Primary Steam System, Water Treatment and Auxiliary Steam System Equipment

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

Pump & Trap Combinations

EZ Plate Instantaneous

HEATING- Heating Accessories RW List Prices Page X - 1. Bronze B&G Circulator Pumps. Iron Body Red Fox B&G Circulator Pump

HVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

Blowdown Separator & Aftercoolers

SECTION HEATING BOILERS

Design and Construction Standards SECTION PLUMBING EQUIPMENT

DIVISION FINNED WATER-TUBE WATER HEATERS

30 F to 300 F Process Temperatures* 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 3/8-1 Solenoid Cooling Valves (VE & 300 F models)

BOILER APPLICATION GUIDE for:

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve

Water Piping and Pumps

A. This Section includes the following domestic water piping specialties:

Indirect Fired Water Heater

VS SERIES NH3 STEAM VAPORIZERS OPERATION MANUAL

THE THERMOSTATIC STEAM TRAP

Installation S HL2X2 High Capacity Manifold System. Table of Contents Rev. B; ECN Bradley Page 1 of 8 11/10/2014

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S

TK-1001, 1101, 1201, 1301, 1601

FUEL-FIRED VERTICAL TUBELESS BOILERS

HEATING- Heating Accessories RW List Prices Page X - 1. Iron Body Red Fox B&G Circulator Pump. Bronze B&G Circulator Pumps

.03 ATMOSPHERIC DEAERATOR

Columbia Boiler Company

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

OPERATING AND MAINTENANCE MANUAL FOR STEAM FIRED WATER HEATER. ELECTRIC HEATER COMPANY BASE MODEL ST and STH

Transcription:

FFH Series Steam Fired Instantaneous Feed Forward Water Heaters CEMLINE CORPORATION P.O. BOX 55 CHESWICK, PENNSYLVANIA 15024 Phone: (724) 274-5430 FAX: (724) 274-5448 www.cemline.com

Operation of Cemline Feed Forward Instantaneous Water Heaters Cemline Feed Forward Water Heaters can supply domestic hot water with a temperature range set point of 105 to 180 deg F. Models are available for flow rates from 15 to 120 gallons per minute. The Cemline Feed Forward Instantaneous Water Heaters (FFH) use a pressure sensing blending valve to mix overheated hot water with cold water to make hot domestic water. Cold water is passed through the tubes of the heat exchanger while 2 to 15 psig steam is piped to the shell of the heat exchanger which overheats the water in the tubes. A differential pressure sensing head then blends the cold water with the over heated hot water to deliver domestic hot water at a stable temperature with an adjustable range of 105 to 180 F. The varying pressures from above and below the diaphragm of the blending valve are used to balance the differential pressure sensing head. A sensing line is run from the cold water supply to the top of the blending valve applying pressure downward on the diaphragm of the blending valve. The blended water s pressure is applied upward upon the diaphragm of the valve from below. When the pressure on the diaphragm is even, the valve is closed and hot water is not being sent out to the system. When there is a demand in the system for hot water the pressure of the blended water begins to decrease. As the blended hot water s pressure drops, the pressure on the diaphragm from the cold water becomes greater than the pressure of overheated hot water on the diaphragm. The greater pressure of the cold water pushes down on the diaphragm, which pushes down on the stem of the blending valve opening up the hot water ports on the valve allowing more overheated hot water to be blended and sent out as hot water into the system. When the demand for hot water stops the pressure of the blended hot water increases equaling that of the cold water, thus raising the diaphragm and the stem of the blending valve which closes off the opened hot water ports and stops the blending of hot water. The valve allows for automatic proportioning of the hot and cold water thereby maintaining the desired set temperature even during conditions of uneven flow. The water is blended quickly, which prevent any lags in response to demand. The blending valve is safe and will shut-off in situations of loss of cold water pressure. Should the movement of the blending valve be restricted by foreign debris carried in the water, a yielding spring arrangement allows the diaphragm and stem to move up, uncovering a heat damper in the characterized blending valve. This damper allows cold water to enter the blended mix, eliminating the possibility of over-heating or scalding. Moving the adjustment rod on the stem of the blending valve easily sets the temperature of the FFH allowing for an easy start-up of the unit. The domestic hot water temperature range is 105 to 180 F. Cemline FFH units can be completely packaged allowing the customer to receive a water heater that only requires connections to be made to the cold water inlet, hot water outlet, steam in, and condensate out. This is the ideal way to get a FFH heater as it reduces piping times at the job site. Heat Exchanger Differential Sensing Head Two Innovations to Ensure Safety Pressure Gauge Steam In Temperature Adjustment Blending Valve Notch prevents over-heating of water at low flow levels. Yielding Spring Condensate Cold Water Heat Damper Blended Hot Water Out 2 Cold Water In Should movement of the blending valve be restricted by foreign matter carried in the water, a yielding spring arrangement allows the diaphragm and stem to move up, uncovering a heat damper in the characterized blending valve. This damper allows cold water to enter the blended mix, eliminating the possibility of over-heating or scalding.

Standard Equipment Cemline Feed Forward Water Heaters Cemline FFH Water Heaters are normally completely packaged and ready to use. All components are sized, mounted and piped prior to shipment. These heaters come complete and require only connection to services. Standard Equipment Heat exchanger: Vessel - Ductile Iron rated for 75 PSI Coil - Copper tubing rated for 150 PSI FFH Models 15, 30, 45, 60, 90: 1/2 O.D. x 18 BWG tubes FFH Models 105, 120: 5/8 O.D. x 18 BWG tubes Blending valve Strainers (main and drip) Outlet Water Temperature Gauge Main Trap Drip Trap Steam Pressure gauge (with pigtail) Options Vessel Material - Cast Steel rated for 150 PSI, Cast Steel 150 PSI A.S.M.E. U Stamp Coil Material - Admiralty, 90:10 Copper Nickel, 316 Stainless Steel Recirculation kit REQUIRED if the water in the system is being recirculated to the unit (for more information see page 7). Non-Packaged Unit Strainers, traps, steam gauge, temperature gauges to be piped at the job site. Packaged Unit Completely packaged and skidded unit. The only connections to be made are the cold water inlet, hot water outlet, steam in, and condensate out. Upstream Pressure Reducing Valve In some installations the steam pressure supplied will be above 15 psig. In these cases Cemline can provide a pilot operated pressure reducing valve (PRV) to be piped upstream of the FFH that will reduce the steam pressure to 15 psig going to the unit. Insulation cover The insulation cover is placed over top of the heat exchanger to prevent heat loss of the heat exchanger. This high quality insulation is an extremely reliable means of minimizing heat loss. FFH water heaters are not recommended for water with hardness over 140 parts per million. If water hardness exceeds 140 ppm either put a water softener in the system or use Cemline SEH series water heaters. Warranty Coil: The heat exchanger coils shall carry an unconditional, non-prorated 10 year guarantee against failure due to thermal shock, mechanical failure or erosion. Pressure Vessel: The heat exchanger pressure vessel shall carry an unconditional, non-prorated 10 year guarantee against any failure. 3

Feed Forward Water Heater (Skid Mounted) Dimensional Data Cemline Skid Mounted Heaters come factory piped and the user need only connect to cold and hot water lines and steam and condensate return lines. B N Cold Water Inlet O Hot Water Outlet C P Steam Inlet H J L K A Front Elevation E D End Elevation G F R Condensate Oulet DIMENSIONS (inches) Model A B C D E F G H J K L FFH-15, FFH-30 28 1 4 14 1 8 55 1 2 37 1 2 30 1 2 6 3 8 4 1 4 45 15 16 34 5 8 22 1 2 12 FFH-45, FFH-60 28 1 4 14 1 8 58 1 4 39 5 8 30 1 2 8 1 2 4 3 8 46 7 8 35 1 4 22 1 4 13 3 4 FFH-75, FFH-90 28 1 4 14 1 4 68 1 4 42 5 8 30 1 2 11 1 2 4 3 4 47 5 8 35 1 4 19 11 FFH-105, FFH-120 31 1 2 15 1 4 68 1 4 44 30 1 2 11 1 2 9 1 2 47 5 8 35 1 4 19 11 End Connection FFH-15/30 FFH-45/60 FFH-75/90 FFH-105/120 N Cold Water Inlet 1 1 2 MNPT 2 MNPT 2 1 2 MNPT 2 1 2 MNPT O Hot Water Outlet 2 FNPT 2 FNPT 2 1 2 FNPT 2 1 2 FNPT P Steam Inlet 3 150# Fig. RF 3 150# Fig. RF 4 150# Fig. RF 4 150# Fig. RF R Condensate Outlet 1 150# Fig. RF 1 1 2 150# Fig. RF 1 1 2 150# Fig. RF 1 1 2 150# Fig. RF Dimensions are approximate and may vary slightly then shown. All dimensions are in inches. Standard tolerance for location of all pipe connections and envelope dimensions is plus or minus 1/2. 4

Feed Forward Water Heater (Non-packaged Units) Dimensional Data Cemline Non-packaged Units must be field piped similarly to the skid mounted option on page 4. Specifying the skid mounted option eliminates most field piping and the skid mounted option is recommended. D E H J D E H J F C G F C G Bottom View Bottom View K Cold Water Inlet A M Cold Water Inlet A K L L Hot Water Outlet B End Elevation Hot Water Outlet B End Elevation Model FFH-15, 30, 45, 60 Model FFH-75, 90, 105, 120 DIMENSIONS (inches) Model A B C D E F G H J K L FFH-15 1 2 2 31 1 2 22 1 2 4 5 8 15 13 16 10 1 4 6 11 16 12 1 16 17 1 2 5 23 32 FFH-15-S* 1 2 2 31 1 2 22 1 2 4 5 8 15 13 16 10 1 16 5 7 8 11 1 4 17 1 2 5 3 4 FFH-30 1 2 2 31 1 2 22 1 2 4 5 8 15 13 16 10 1 4 6 11 16 12 1 16 17 1 2 5 23 32 FFH-30-S* 1 2 2 31 1 2 22 1 2 4 5 8 15 13 16 10 1 16 5 7 8 11 1 4 17 1 2 5 3 4 FFH-45 2 2 31 1 2 22 1 2 5 5 8 17 13 16 7 8 5 5 8 12 1 2 17 1 2 5 3 4 FFH-60 2 2 31 1 2 22 1 2 5 5 8 17 13 16 7 8 5 5 8 12 1 2 17 1 2 5 3 4 DIMENSIONS (inches) Model A B C D E F G H J K L M FFH-75/90 2 1 2 2 1 2 29 7 16 24 6 7 8 13 15 16 6 1 2 3 7 8 10 3 4 19 3 4 6 5 8 31 FFH-105/120 2 1 2 2 1 2 34 3 8 27 13 16 8 19 31 32 6 31 32 7 1 4 15 1 4 19 3 4 6 5 8 31 *Steel shell unit rated for 150 psi. For all other units, steel and cast iron dimensions are the same. 5

Feed Forward Water Heater Sizing Data The sizing given below covers most applications. Contact factory for selections with different starting and/or ending temperatures. Heater Sizing Chart (Gallon Per Minute) Inlet Set Temp Temp Steam Pressure-PSIG Model F F 2 5 10 15 15 15 15 15 FFH15 29 30 30 30 FFH30 105 44 45 45 45 FFH45 40 to 58 60 60 60 FFH60 110 73 75 75 75 FFH75 87 90 90 90 FFH90 102 105 105 105 FFH105 116 120 120 120 FFH120 14 15 15 15 FFH15 27 30 30 30 FFH30 41 45 45 45 FFH45 40 120 54 60 60 60 FFH60 68 75 75 75 FFH75 81 90 90 90 FFH90 95 105 105 105 FFH105 108 120 120 120 FFH120 10 11 12 14 FFH15 20 22 24 27 FFH30 33 38 41 44 FFH45 40 140 46 54 58 60 FFH60 58 68 73 75 FFH75 69 81 87 90 FFH90 81 95 102 105 FFH105 92 108 116 120 FFH120 10 10 11 12 FFH15 17 19 21 23 FFH30 29 34 37 39 FFH45 40 150 40 49 53 54 FFH60 50 61 66 68 FFH75 60 73 79 81 FFH90 70 86 93 95 FFH105 80 98 106 108 FFH120 FFH15 FFH30 26 31 33 35 FFH45 40 160 34 41 44 46 FFH60 43 51 55 58 FFH75 51 61 66 69 FFH90 60 72 77 81 FFH105 68 82 88 92 FFH120 FFH15 FFH30 16 17 19 21 FFH45 40 180 21 23 25 28 FFH60 26 29 31 35 FFH75 31 34 37 42 FFH90 37 40 44 49 FFH105 42 46 50 56 FFH120 To calculate the capacity of available alternate coils, mutiply the capacity from the table by the following factors: Coil Materials Capacity Factor Admiralty 0.95 Cupro-nickel 0.81 Stainless steel 0.85 Inlet Set Temp Temp Steam Pressure-PSIG Model F F 2 5 10 15 15 15 15 15 FFH15 30 30 30 30 FFH30 105 45 45 45 45 FFH45 60 to 60 60 60 60 FFH60 110 75 75 75 75 FFH75 90 90 90 90 FFH90 105 105 105 105 FFH105 120 120 120 120 FFH120 15 15 15 15 FFH15 30 30 30 30 FFH30 45 45 45 45 FFH45 60 120 60 60 60 60 FFH60 75 75 75 75 FFH75 90 90 90 90 FFH90 105 105 105 105 FFH105 120 120 120 120 FFH120 12 13 14 15 FFH15 23 25 27 30 FFH30 40 42 44 45 FFH45 60 140 57 59 60 60 FFH60 71 74 75 75 FFH75 85 88 90 90 FFH90 100 103 105 105 FFH105 114 118 120 120 FFH120 10 11 12 14 FFH15 20 22 24 27 FFH30 35 38 41 44 FFH45 60 150 49 54 57 60 FFH60 61 68 71 75 FFH75 73 81 85 90 FFH90 86 95 100 105 FFH105 98 108 114 120 FFH120 FFH15 FFH30 32 37 38 42 FFH45 60 160 42 49 51 56 FFH60 53 61 64 70 FFH75 63 73 76 84 FFH90 74 86 89 98 FFH105 84 98 102 112 FFH120 FFH15 FFH30 22 25 29 33 FFH45 60 180 29 33 39 44 FFH60 36 41 49 55 FFH75 43 49 58 66 FFH90 51 58 68 77 FFH105 58 66 78 88 FFH120 To calculate the #/hr of steam required. #/hr = [(GPH) x (T2-T1)] 100 To calculate condensate load. GPM condensate = #/hr 500 GPH = GPM x 60 T2 = Outlet Temperature T1 = Inlet Temperature 6

Recirculation Kit A recirculation kit is REQUIRED if the water in the system is being recirculated. Temperature control problems will occur if the recirculation kit is not used in a recirculating system. When using the Cemline FFH water heater in a water system with recirculated water, a recirculation kit must be used with the heater. Temperature control problems will occur if a recirculation kit is not installed in a recirculated system. The problem experienced is that during times of little or no hot water usage, the recirculatied water will be returned to the heater hot. The movement of the water through the system will cause the blending valve to sense a pressure drop and cause the valve to open and heat the hot water hotter. Eventually the water in the system will become dangerously hot. Therefore when recirculating water it is essential that a reciriclation kit be supplied. The recirculation kit allows for the proper mixing of hot and cold water into the system through the use of a balancing valve and a 3-way thermostatic valve. The mixing valve allows for the diverting of hot water away from the heater if the system temperature is already at the heaters set point. For safety purposes the mixing valve is non-adjustable, preventing accidental changes in the hot water system temperature thus preventing any over-temperature situations. See the operation schematic below. Operation Schematic Check Valve Hot Water Return Balancing Valve Check Valve B A C TCV Three Way Thermostatic Valve (Thermal Capsule) Recirculating Pump Check Valve Cold Water Supply Recirculation Package Hot Water Supply Specification Cemline FFH model low pressure steam water heater, for use on 2-15 psig steam consisting of an integrally piped heat exchanger, mounted on a heavy-duty angle iron frame heater control package capable of supplying GPM off hot water when heated from F to F with out the use of thermostatic control devices or storage tanks. Heaters shall be capable of maintaining the +/- 3 F over a flow range of a few percent to 100%. The water shall flow through the tubes and steam in the shell. Heater shall be supplied with main and drip trap, main and drip strainer, dial thermometer, and steam pressure gauge. The unit shall include connections in the manifolds to measure pressures and temperatures. Optional Recirculation Kit (Required on Recirculated Water Systems) The heater shall be equipped with an integral recirculation system with an adjustable valve to set the recirculation temperature. The recirculation system shall be integrally mounted and shall not alter the overall dimensions of the heater. Recommended skid mounted package Cemline FFH steam fired water heater shall be factory piped with main and drip steam traps, main and drip strainers, dial thermometer, and steam pressure gauge. Heater and components shall be mounted on angle iron frame and shall be shipped complete from factory so owner need only connect steam, condensate outlet, cold water inlet and hot water outlet pipes to the package. Complete package to be pressure tested for leaks. Unit to be assembled so that is sufficient room between heat exchanger and traps for proper operation. 7

Sales Offices Alaska Hawaii Puerto Rico Saudi Arabia Taiwan U.A.E. Available Cemline Brochures www.cemline.com Product Sizing Programs Brochures I.O.M. Manuals Drawings & Specifications Agent Locator Plant Tour STONESTEEL - Water Storage Tanks - Jacketed Storage Tanks - Commercial Electric and Packaged Copper Coil Water Heaters Submerged Heating Coils Replacement Tube Bundles Steel Tanks Chilled Water Buffer Tanks System Efficiency Buffer Tanks Electric Boilers Stainless Compact Packaged Copper Coil Water Heaters - Semi-instantaneous, Instantaneous Unfired Steam Generators Condensed Catalog Cemline is represented in all major cities. Please contact your local representative or call Cemline Corporation. 2017 Cemline Corporation All Rights Reserved. All trademarks on this brochure are the property of Cemline Corporation, unless otherwise noted or in any other way set forth as a third party rights. Unauthorized use of these trademarks, as well as the materials presented on this site, is expressly prohibited and constitutes a violation of the intellectual property rights of Cemline Corporation. Vol. 3.1 Scan to view our mobile web link. CEMLINE CORPORATION P.O. BOX 55 CHESWICK, PENNSYLVANIA 15024 Phone: (724) 274-5430 FAX: (724) 274-5448 www.cemline.com