Lab-Quality Results for Point-of-Care Testing ph pco 2 po 2 Na + K + Ca ++ PT APTT ACT ACT-LR Hematocrit Immediate Care Diagnostics
IL GEM Premier TM 3000 Lab-Quality Results for Point-of-Care Testing Comprehensive Menu Acid-Base Balance Electrolyte Balance Coagulation Other Metabolite Disorders * In development. The final performance characteristics of these tests have not been established Lab-Quality Results Maintains laboratory quality through: State-of-the-art patented planar sensors. Automatic calibration. On-board QC and patient data management program. QC and authorized user lock-out features. Available remote system control through IL IMPACT TM Information Management System. Ease of Use Disposable cartridge technology. Self-contained cartridges include all components necessary to perform analysis: sensors, calibrating solutions, gases, and waste. Totally maintenance-free operation. Test selections made by a simple keystroke on touch screen. Flexible test requisitions; individual test or user-defined panels.
...available with Coagulation module Work consolidation thru Integrated Whole blood Coagulation testing The GEM PCL TM (Portable Coagulation Laboratory) can be integrated to the IL GEM Premier 3000 to create a consolidated Critical Care testing workstation for Blood Gas, Electrolytes, Hematocrit, and PT, APTT, ACT, and ACT-LR in whole blood samples. Single user interface Integrated interface with HIS/LIS or information management system Integrated QC and patient data management
Cost-effective Point-of-Care Testing IL s exclusive multi-use cartridge technology enables the testing of critical analytes close to the patient in a cost-effective and convenient manner: Efficient multi-use cartridge Operating costs comparable to traditional blood gas instruments Simple inventory management 43,2 (17 ) 30,5 (12 ) 30,7 (12 )
GEM Premier 3000 Product Specifications Analytes Measured Analytes Displayed Ranges Resolution ph 6.80 to 7.80 0.01 pco 2 5 to 115 mmhg 1 mmhg po 2 0 to 760 mmhg 1 mmhg Na + 100 to 200 mmol/l 1 mmol/l K + 0.1 to 20.0 mmol/l 0.1 mmol/l Ca ++ 0.1 to 5.0 mmol/l 0.01 mmol/l Hct 15 to 65% 1% Derived Analytes Displayed Ranges Resolution HCO 3-3.0 to 60.0 mmol/l 0.1 mmol/l HCO 3 - (std) 3.0 to 60.0 mmol/l 0.1 mmol/l TCO 2 3.0 to 60.0 mmol/l 0.1 mmol/l BE (B) -30.0 to +30.0 mmol/l 0.1 mmol/l BE ecf Base on measured value 0.1 mmol/l SO 2 c 0 to 100% 1% Ca ++ (7.4) 0.1 to 5.0 mmol/l 0.01 mmol/l Physical Specifications GEM Premier 3000 Instrument Size and Weight in cm (inches)/kg (pounds) Width 30.5 (12.0) Depth 30.7 (12.0) Height 43.2 (17.0) Weight 13.4 (29.5) Power Requirements Utilizes a switching power supply; accommodates 90-264 VAC, 50-60 Hz. Sixty minute power interrupt allows transport without power. Instrument cannot be operated during power interrupt. Temperature Control Electrode chamber maintained at 37 C nominal. Data Output Port 3 RS-232 Serial I/O Ports, 1 Parallel Printer Port, 1 Ethernet Port Product Safety UL listed under UL-544, complies with IEC 1010-1. Complies with European CE mark requirements. GEM Premier Pak Cartridge Size and Weight in cm (inches)/kg (pounds) Width 21.6 (8.5) Depth 7.6 (3.0) Height 15.2 (6.0) Weight 1.9 (4.2) Capacity/Expiration 150 or 300 test cartridges: 21-day use life. Sample Volume 135 µl. Sample Type Whole blood with addition of approximately 25 USP units/ml. Sodium Heparin or Lithium Heparin. Measurement ph, pco 2, Na +, K +, Ca ++ potentiometric Methodology po 2 amperometric, Hct conductivity. Calibration Frequency Automatic at regularly scheduled intervals. Response Time 104 seconds from sample introduction. A Total System for Critical Care Testing throughout Your Institution Laboratory RT Point-of-Care Information Management IL GEM Premier 3100 ABG, ISE, HCT, Coagulation IL s GEM Premier is a key element in IL s total solution for immediate care testing throughout your institution. All elements of the IL system can be integrated into a single, cohesive information management flow to deliver a turnkey operation for a single hospital or a network of provider institutions. Along with the reliability and innovation we have delivered for over forty years, IL gives you the diagnostic information you need, when and where you need it most. * With the optional Coagulation Module IMPACT for Critical Care Information Management System IL Synthesis ABG, ISE, CO-Ox, HCT, Glucose, Lactate, Bilirubin, PT, APTT, ACT, ACT-LR* Immediate Care Diagnostics
Worldwide Locations Instrumentation Laboratory Corporate Headquarters Aragón 90-08015 Barcelona, Spain P.O. Box 35027 (08080) Telephone: 34-93-4010101 Fax: 34-93-4513745 US, Canada, Latin America, Headquarters Instrumentation Laboratory Company 101 Hartwell Avenue - P.O. Box 9113 Lexington, MA 02421-3125 U.S.A. Telephone: 1-781-861-0710 Fax: 1-781-861-1908 Mexico Instrumentation Laboratory Diagnostics, S.A. DE C.V. Londres 47 - Colonia Juarez - Mexico, D.F. 06600 Telephone: 52-5-525-8639 - Fax: 52-5-525-8539 Africa ESSE 3 10024 MONCALIERI (TO) tel +39 011 681 03 01 fax +39 011 681 31 87 Pacific Headquarters Instrumentation Laboratory Hamamatsucho General Bldg. 6F 2-2-15 Hamamatsucho Minato-ku, Tokyo 105, Japan Telephone: 81-3-3437-6350 Fax: 81-3-3437-6352 Japan Instrumentation Laboratory Hamamatsucho General Bldg. 6F 2-2-15 Hamamatsucho Minato-ku, Tokyo 105, Japan Telephone: 81-3-3437-6350 Fax: 81-3-3437-6352 Hong Kong Instrumentation Laboratory SpA 29 th Floor Wing On Centre 111 Connaught Road Central Hong Kong Telephone: 852-27927773 Fax: 852-27919972 Europe, Middle East, Africa Headquarters Instrumentation Laboratory SpA Viale Monza 338-20128 Milan, Italy Telephone: 39-02-25221 Fax: 39-02-2575250 Austria Instrumentation Laboratory Gesellschaft m.b.h. Baldassgasse, 5 - Postfach 54 1211 Wien, Austria Telephone: 43-1-2565800-0 - Fax: 43-1-2565800-88 Belgium Instrumentation Laboratory (Belgium) N.V./S.A. Excelsiorlaan 81 bus 1 1930 Zaventem (Brussels) - Belgium Telephone: 32-2-7252052 - Fax: 32-2-7212409 Czech Instrumentation Laboratory Czech* 10800 Praha 10 Plananska 1 - Czech Telephone: 420-2-7816047 - Fax: 420-2-7817434 France Instrumentation Laboratory S.A. 32 Avenue de Saint-Mandé B.P. 35-75560 Paris Cedex 12 France Telephone: 33-1-53338600 - Fax: 33-1-53338601 Germany Instrumentation Laboratory GmbH Klausnerring 4 D-85551 Kirchheim bei München, Germany Telephone: 49-89-909070 - Fax: 49-89-90907116 Italy Instrumentation Laboratory SpA Viale Monza 338-20128 Milan, Italy Telephone: 39-02-25221 - Fax: 39-02-2575250 Lithuania Instrumentation Laboratory (Lietuva) B.I. Savanoriu 281A 3009 Kaunas - Lithuania Telephone: 370-7-313157 - Fax: 370-7-313159 Poland Instrumentation Laboratory Poland** 03-699 Warszawa Wolińska 4 - Poland Telephone: 22-8447412 - Fax: 22-8449963 The Netherlands Instrumentation Laboratory (Netherlands) B.V. Moskesbaan 2 - AH Breda - The Netherlands Telephone: 31-76-5480100 - Fax: 31-76-5480102 United Kingdom Instrumentation Laboratory (U.K.) Ltd. Kelvin Close - Birchwood Science Park Warrington, Cheshire WA3 7PB - England Telephone: 44-1925-81-0141 - Fax: 44-1925-826708 * IL Czech is the Diagnostic Division of Comesa Czech, a CH-Werfen Company ** IL Poland is the Diagnostic Division of Comesa Polska, a CH-Werfen Company Instrumentation Laboratory on Internet: http://www.4ci.com This Brochure is used throughout the world. Applications / tests listed may not yet be approved by the regulatory authorities in your country. Please contact the appropriate office above for specific information regarding availability in your country. IL product specifications are subject to modification to assure the highest quality performance. Some of the IL sites may still be in the process of completing ISO. GEM is a registered trademark, and IMPACT, PCL, Premier and IL Synthesis are trademarks of Instrumentation Laboratory. Copyright 1999 Instrumentation Laboratory p/n 98086-01 Rev. 0 All rights reserved - Printed in Italy - Grafica Briantea 05/00 A CH Werfen Company