Silhouette Installation and Wiring Instructions

Similar documents
PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Lo-Carbon Quadra Centrifugal Fan

Lo-Carbon SOLO Plus SELV Centrifugal Bathroom/Toilet Fan

VA 150 A, VA 150 P WINDOW EXTRACT FAN. Installation and Wiring Instructions V/1/50Hz

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

HR200WK Through the wall Heat Recovery Ventilator

Lo-Carbon Quadra Centrifugal Fan

Centrif Duo & Centrif Duo Plus

Lo-Carbon Quadra SELV

Integra. Integra Plus EC MVHR. Installation & Commissioning. Stock Ref. N EC Integra Plus EC PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT.

Lo-Carbon SELV Tempra

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

Lo-Carbon PoziDry Pro

Lo-Carbon T-series Window & Roof Models

SUPER T WALL FANS. Installation and Wiring Instructions

VA100 SELV 12 RANGE. Installation and Wiring Instructions IPX7

Vent-Axia Svara Multifunctional app controlled fan. Important Information 2 Installation and Wiring Instructions 3-11 Accessories 12 Pin Code 12

T-SERIES. Wall & Panel Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS

Trimbox Mixed Flow Fans. Product Manual. ventilation systems TP220T TP221T TP222T TP223T

DUCT AIR HEATER WITH BUILT-IN CONTROLS. Installation & User Instructions. Stock Ref T T T3

Long Case Axial Fan. Installation and Wiring Instructions V/1/50Hz & V/3/50Hz

Sentinel. Kinetic Advance MVHR. Installation & Commissioning. Stock Ref. N Advance S Advance SX

Installation and Wiring Instructions

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

Sentinel Kinetic MVHR RANGE

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N

G Installation manual Solitude - dmev unit

Installation manual Mori HR

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions

CI/SfB (57.7) 2nd edition. Lo-Carbon Quadra

Simply Silent Contour 4 (100mm) Axial Extraction Fan

nergybulbs.co.uk Domestic AC Fans 230V Installation and Operating Guide Quick Order Hotline or

100 FLUEBOOST

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

Installation & Operating Instructions

l i nda b we si mpl i f y c onstr u ction Conforms ErP Ecodesign Lot 6 Residential and non-residential air handling units

Decentralised comfort ventilation unit Zehnder ComfoSpot 50

Xpelair Simply Silent TM Contour Fan

PUREAIR SENSE. Instruction Manual. A product by. B at hroom Fan wi t h O dour Sen se Tec h n ology Vent-Axia PureAir Sense F&W Manual.

Model: Kair Whole House Ventilator Model Number: KHRVWH2000

Stainless Steel Chimney Extractor

IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS.

dmev Unit Quietest dmev available. Discreet, tasteful styling. Single fan for use in all applications.

ELEGANCE IPX4 IPX7. Low Carbon Fan with EC Motor Installation and Operating Instructions. 6 models:

Xpelair Simply Silent TM DX100 Fan

CLASSIC-100. Instruction leaflet. Instruction leaflet

CI/SfB (57.7) 1st Edition. Lo-Carbon Response/SELV dmev Unit. A new generation of Lo-Carbon continuous running fans

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

FLUEBOOST. flueboost 350 gas fire model

Stainless Steel Chimney Extractor

Stainless Steel T-Box Extractor

Warnings, Safety Information and Guidance

Purge Ventilation Unit. Product Manual. ventilation systems TP625

Xpelair Simply Silent DX150

LV100 Standard LV100PC Pull Cord LV100T Timer LV100H Humidistat LV100HP Humidistat and Pull Cord LV100PIR

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

ENERGIA ЕНЕРГИЯ ΕΝΕΡΓΕΙΑ ENERGIJA ENERGY ENERGIE /2014

MODEL: BV400 Part No:

irconcentre.co.uk airooncentre.co.uk

ENERGIA ЕНЕРГИЯ ΕΝΕΡΓΕΙΑ ENERGIJA ENERGY ENERGIE /2014

Xpelair Simply Silent DX100

Vireo HR155WM / HR155CM / HR185WM Mechanical Ventilation with Heat Recovery User / Homeowner Guide

AXIAL FANS USER S MANUAL

S ILENT Series INSTALL SILENCE, INSTALL QUALITY OF LIFE. The Quietest Extractors in the World in their Category 26,5

Titon CME1 Q Plus Mechanical Extract Ventilation Unit

Installation & Operating Instructions

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use

User and maintenance manual

60cm Integrated Turbo Extractor

"Microbox" DC Models MBOX 125/2DC MBOX 125/2DC204

Domestic AC Fans 230V Installation and Operating Guide. eco. 230V AC Base Models: icon eco icon icon icon

Hand Dryer Installation & User Manual

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

GB User and maintenance manual

HOTLINE:

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

Installation and Maintenance

90cm Chimney Extractor

ELTA FANS IN-LINE MIXED FLOW FAN IMF100 / 125 / 150 / 200 INCLUDING MODELS WITH BUILT-IN-RUN-ON TIMERS T

CMX-S. Company name: Contact: Tel: Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions

European Parliament and of the Council with regard to energy labelling of residential ventilation units. (Text with EEA relevance) (2016/C 416/06)

WHHR Midi & Midi Lite

CI/SfB (57.7) 2nd Edition WINNER2011. Winners of the Energy Efficiency Initiative 2011 Award with our Lo-Carbon Continuous Ventilation Product Range.

KADO LUX LED EXHAUST FAN 200

Installation and Maintenance

Xpelair Simply Silent DX100B

INSTALLATION INSTRUCTIONS USER GUIDE

Thank you for choosing EnviroVent

Turbo. Service Instructions

Transcription:

Silhouette Installation and Wiring Instructions Stock Ref. N 45 40 55B (100B) 44 51 61 (125B) 45 40 59B (150X) 45 40 56B (100T) 44 51 62 (125T) 45 40 60B (150XT) 45 40 57B (100HT) 44 51 63 (125HT) 45 40 61B (150XHT) 45 40 58B (100TM) 220-240V~50Hz PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS. IPX4

Installation and Wiring Instructions for the Silhouette Range of Extractor Fans. IMPORTANT: READ THESE INSTRUCTIONS BEFORE COMMENCING THE INSTALLATION DO NOT install this product in areas where the following may be present or occur: Excessive oil or a grease laden atmosphere. Corrosive or flammable gases, liquids or vapours. Ambient temperatures higher than 40 C or less than 5 C. Possible obstructions which would hinder the access or removal of the Fan. SAFETY AND GUIDANCE NOTES A. All wiring to be in accordance with the current I.E.E. Regulations, or the appropriate standards of your country and MUST be installed by a suitably qualified person. B. The Fan should be provided with a local isolator switch capable of disconnecting all poles, having a contact separation of at least 3mm. C. Ensure that the mains supply (Voltage, Frequency, and Phase) complies with the rating label. D. The Fan should only be used in conjunction with the appropriate Vent-Axia products. E. The fan should only be used in conjunction with fixed wiring. F. When the Fan is used to remove air from a room containing a fuel-burning appliance, ensure that the air replacement is adequate for both the fan and the fuel-burning appliance. G. The Fan should not be used where it is liable to be subject to direct water spray for prolonged periods of time. H. Where ducted Fans are used to handle moisture-laden air, a condensation trap should be fitted. Horizontal ducts should be arranged to slope slightly downwards away from the Fan. I. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. J. Children should be supervised to ensure that they do not play with the appliance. 2

K. Stationary appliances not fitted with means for disconnection from the supply mains having a contact separation in all poles that provide full disconnection under over voltage category III, the instructions state that means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules. DESCRIPTION The Silhouette 100mm & 125mm axial extract fans are suitable for domestic bathrooms and W.C s. The Silhouette 125mm & 150mm axial extract fans are suitable for domestic kitchens and utility rooms. They are available as wall or panel/ceiling mounted models with shutter, timer, humidity and PIR combinations (100mm model only). ACCESSORIES (not supplied) WALL FITTING KIT A range of 100mm, 125mm and 150mm wall kits are available for installing into most walls using telescopic liners supplied. Fan Stock Reference Size White Brown 100mm 254102 254100 125mm 455226 N/A 150mm 140902A 140903A A. INSTALLATION IMPORTANT: The fan should only be used in conjunction with fixed wiring. PANEL/CEILING MOUNTING 1. For panel/ceiling mounting the fan should be installed into a closed duct protected by an exterior air grille that must comply with the standard requirements of your country to prevent access to the fans impeller. 2. Cut a 105mm diameter hole for 100mm fans, a 130mm hole for 125mm fans or a 155mm diameter hole for 150mm fans. 3. Loosen the screw at the bottom of the grille and remove the front grille. Mark the screw centres through the holes in the fan back plate. Drill, plug and screw into position. 4. After installation, ensure impeller rotates freely and the shutters can open. 5. Replace the grille and tighten the retaining screw. WALL MOUNTING 1. For wall mounting either cut a 115mm diameter hole for 100mm fans, a 140mm hole for 125mm fans or a 170mm diameter hole for 150mm fans, through the wall and insert the wall sleeve. Slope the sleeve slightly downwards away from the fan. Cut to length and cement both ends into position flush with the wall faces. 2. Loosen the screw in the bottom of the grille and remove the front grille. Mark the screw centres through the holes in the fan back plate. Drill, plug and screw into position. Fix exterior grille into position with the louvres positioned downwards. (Note:- The grille must comply with the standard requirements of your country to prevent access to the fans impeller. The wall kit used in this installation should provide a minimum ducting length of 100mm from the fans back plate to the inside of the external grille). 3. After installation, ensure impeller rotates freely and the shutters can open. 4. Replace the grille and tighten the retaining screw. 3

B. WIRING. WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPPLY DURING THE INSTALLATION / OR MAINTENANCE. IMPORTANT The fan should only be used in conjunction with fixed wiring. The cross - sectional area of supply cord used should be ranged from 1-1.5mm 2. Cable entry can only be made from the rear of the fan. The extraction fan is suitable for connection to 220-240V 50Hz supply. The fan is a class ll double insulated product and MUST NOT be earthed. 1. Select and follow the appropriate wiring diagram. (Fig. 2,3 or 4) 2. Check all connections have been made correctly and ensure all terminal connections and cable clamps are securely fastened. 3. Ensure the impeller rotates and is free from obstructions. C. SETUP WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPPLY DURING THE INSTALLATION / OR MAINTENANCE. NOTE On all 150mm fans the shutter may take up to one minute to activate on start-up, and the same amount of time to close when the fan is switched off. SILHOUETTE 100B/125B/150X Single speed fan. Controlled by remote switch (e.g. light switch or auto sensor) Fig.2. SILHOUETTE 100T/125T/150XT Single speed with overrun timer. The fan can be wired to a lighting circuit switch. Fig.4. or wired for a basic on/off operation wire as Fig 3. When switched ON, the fan will operate at full speed and will continue to run for a pre-set time after the switch is turned OFF. TIMER ADJUSTMENT BEFORE ADJUSTING THE TIMER, SWITCH OFF THE MAINS SUPPLY. TIMER SHOULD ONLY BE ADJUSTED BEFORE OR DURING INSTALLATION. 1. Remove the fan grille. The controller is factory set at 15 minutes approx. The overrun time period can be adjusted from 5-25 minutes by altering the adjuster on the control PCB. 2. To REDUCE the operating time, use a small screwdriver to turn the adjuster Fig.5. ANTI- CLOCKWISE. 3. To INCREASE the operating time, use a small screwdriver to turn the adjuster Fig.5. CLOCKWISE. 4. Replace the fan grille. SILHOUETTE 100HT/125HT/150XHT The fan contains an integral humidity controller. In automatic mode the controller switches the fan on at full speed when the room Relative Humidity (RH) reaches the set-point. The fan will continue to run until the room RH falls below the set-point. These fans also include a built in timer function. The timer can be activated by removing the Jumper JP1, this will give the fan a fixed over run time of approx. 15 mins. 4

HUMIDITY SET-POINT ADJUSTMENT BEFORE ADJUSTING THE CONTROLLER, SWITCH OFF THE MAINS SUPPLY. HUMIDISTAT SHOULD ONLY BE ADJUSTED BEFORE OR DURING INSTALLATION. 1. Remove the fan grille. The controller is factory set to switch on at about 70% RH. The humidity set point can be adjusted from 65-95%RH by altering the adjuster on the control PCB. 2. To LOWER the set-point use a small screwdriver to turn the adjuster Fig.6. ANTI- CLOCKWISE. This makes the controller MORE sensitive. 3. To RAISE the set-point use a small screwdriver to turn the adjuster Fig.6. CLOCKWISE. This makes the controller LESS sensitive. 4. Replace the fan grille. NOTE! DO NOT TOUCH HUMIDITY SENSOR. SILHOUETTE 100TM Single speed with PIR (passive infra-red) detector and overrun timer. The fan starts automatically when a movement is detected and will continue to operate for the set overrun time period. (See Timer Adjustment section above) Fig. 2 and 5. D. SERVICING AND MAINTENANCE. WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPPLY DURING MAINTENANCE. 1. At intervals appropriate to the installation, the fan should be inspected and cleaned to ensure there is no build up of dirt or other deposits. 2. Wipe the inlets and front face with a damp cloth until clean. The fan has sealed for life bearings, which do not require lubrication. Fig.1. Fig.2 5

Fig.3 Timer model wired as a Basic version (link between L & LS enables fan to switch on or off when power is put onto the fan). Fig.4 Fig.5. Fig.6. To activate the timer function remove jumper JP1. Once removed the fan will run on for a fixed time period of approx. 15 mins. Timer Adjustment Humidity Adjustment + I + I To REDUCE the operating time, use a small screwdriver to turn the adjuster ANTI-CLOCKWISE. To INCREASE the operating time, use a small screwdriver to turn the adjuster CLOCKWISE. To LOWER the set-point use a small screwdriver to turn the adjuster ANTI-CLOCKWISE. This makes the controller MORE sensitive. To RAISE the set-point use a small screwdriver to turn the adjuster CLOCKWISE. This makes the controller LESS sensitive. 6

PRODUCT FICHE For Residential Ventilation Units (Complying Commission Delegated Regulation (EU) No 1254/2014) Name: Vent-Axia/Manrose Vent-Axia Vent-Axia Vent-Axia Vent-Axia Model ID (Stock Ref.) : Silhouette 100B - 454055 Silhouette 100T - 454056 Silhouette 100HT - 454057 Silhouette 100TM - 454058 SEC Class F F D D SEC Value ('Average') 13.97 15.72 26.23 26.23 SEC Value ('Warm') 6.32 7.11 11.86 11.86 SEC Value ('Cold') 27.32 30.75 51.31 51.31 Label Required? (Yes/No=Out of scope) No No No No Declared as: RVU or NRVU/UVU or BVU RVU-UVU RVU-UVU RVU-UVU RVU-UVU Speed Drive Multi-Speed Multi-Speed Multi-Speed Multi-Speed Type HRS (Recuperative, Regenerative, None) None None None None Thermal Eff: [ (%), NA(if none)] N/A N/A N/A N/A Max. Flow Rate (m3/h) 75.60 75.60 75.60 75.60 Max. Power Input (W): (@Max.Flow Rate) 15.00 15.00 15.00 15.00 LWA: Sound Power Level (db) 50.53 50.53 50.53 50.53 Ref. Flow Rate (m3/s) 52.92 52.92 52.92 52.92 Ref. Pressure Diff. (Pa) TBC TBC TBC TBC SPI [W/(m3/h)] 0.28 0.28 0.28 0.28 Control Factor & Control Typology: (CTRL/ Typology) Control Factor; CTRL 1.00 0.95 0.65 0.65 Control Typology Manual Control Clock Control Local Demand Control Local Demand Control Declared: -Max Internal & External Leakage Rates(%) for BVUs or carry over (for regenerative heat exchangers only), TBC TBC TBC TBC -&Ext. Leakage Rates (%) for Ducted UVUs; Mixing Rate of Non-Ducted BVUs not intended to be equipped with one duct connection on either supply or extract air side; N/A N/A N/A N/A Filter Warning (RVU) No No No No For UVUs (Instructions Install Regulated Supply/Extract Grilles Façade) In F&W In F&W In F&W In F&W Internet Address (for Disassembly Instructions) www.vent-axia.com www.vent-axia.com www.vent-axia.com www.vent-axia.com Sensitivity p. Variation@+20/-20 Pa: (for Non- Ducted Vus) TBC TBC TBC TBC Air Tightness-ID/OD-(m3/h) (for Non-Ducted Vus) TBC TBC TBC TBC Annual Electricity Consumption: AEC (kwh/a) 9.76 9.04 5.12 5.12 Annual Heating Saved: AHS (kwh/a) AHS: Average 13.97 15.72 26.23 26.23 AHS: Warm 6.32 7.11 11.86 11.86 AHS: Cold 27.32 30.75 51.31 51.31

PRODUCT FICHE For Residential Ventilation Units (Complying Commission Delegated Regulation (EU) No 1254/2014) Name: Vent-Axia Vent-Axia Vent-Axia Model ID (Stock Ref.) : Silhouette 125 B - Silhouette 125 T - Silhouette 125 H - 445161 445162 445163 SEC Class F E C SEC Value ('Average') 13.97 15.72 26.23 SEC Value ('Warm') 6.32 7.11 11.86 SEC Value ('Cold') 27.32 30.75 51.31 Label Required? (Yes/No=Out of scope) No No No Declared as: RVU or NRVU/UVU or BVU RVU-UVU RVU-UVU RVU-UVU Speed Drive Multi-Speed Multi-Speed Multi-Speed Type HRS (Recuperative, Regenerative, None) None None None Thermal Eff: [(%), NA(if none)] N/A N/A N/A Max. Flow Rate (m3/h) 162.00 162.00 162.00 Max. Power Input (W):(@Max.Flow Rate) 20.00 20.00 20.00 LWA: Sound Power Level (db) 57.52 57.52 57.52 Ref. Flow Rate (m3/s) 0.03 0.03 0.03 Ref. Pressure Diff. (Pa) N/A N/A N/A SPI [W/(m3/h)] 0.18 0.18 0.18 Control Factor & Control Typology: (CTRL/ Typology) Control Factor; CTRL 1.00 0.95 0.65 Control Typology Manual Control Clock Control Local Demand Control Declared: -Max Internal & External Leakage Rates(%) for BVUs or carry over (for regenerative heat exchangers only), N/A N/A N/A -&Ext. Leakage Rates (%) for Ducted UVUs; Mixing Rate of Non-Ducted BVUs not intended to be equipped with one duct connection on either supply or N/A N/A N/A extract air side; Position and description of visual filter warning for RVUs intended for use with filters, including text pointing out the importance of regular filter changes for performance and N/A N/A N/A energy efficiency of the unit For UVUs (Instructions Install Regulated Supply/Extract Grilles Façade) In F&W In F&W In F&W Internet Address (for Disassembly Instructions) www.ventaxia.coaxia.coaxia.com www.vent- www.vent- Sensitivity p. Variation@+20/-20 Pa: (for Non-Ducted Vus) N/A N/A N/A Air Tightness-ID/OD-(m3/h) (for Non-Ducted Vus) N/A N/A N/A Annual Electricity Consumption: AEC (kwh/a) 2.43 2.25 1.27 Annual Heating Saved: AHS (kwh/a) AHS: Average 13.97 15.72 26.23 AHS: Warm 6.32 7.11 11.86 AHS: Cold 27.32 30.75 51.31

PRODUCT FICHE For Residential Ventilation Units (Complying Commission Delegated Regulation (EU) No 1254/2014) Name: Vent-Axia Vent-Axia Vent-Axia Model ID (Stock Ref.) : Silhouette 150 X - Silhouette 150 XT Silhouette 150 XH 454059-454060 - 454061 SEC Class F E C SEC Value ('Average') 13.97 15.72 26.23 SEC Value ('Warm') 6.32 7.11 11.86 SEC Value ('Cold') 27.32 30.75 51.31 Label Required? (Yes/No=Out of scope) No No No Declared as: RVU or NRVU/UVU or BVU RVU-UVU RVU-UVU RVU-UVU Speed Drive Multi-Speed Multi-Speed Multi-Speed Type HRS (Recuperative, Regenerative, None) None None None Thermal Eff: [(%), NA(if none)] N/A N/A N/A Max. Flow Rate (m3/h) 241.20 241.20 241.20 Max. Power Input (W):(@Max.Flow Rate) 20.00 20.00 20.00 LWA: Sound Power Level (db) 60.52 60.52 60.52 Ref. Flow Rate (m3/s) 0.05 0.05 0.05 Ref. Pressure Diff. (Pa) N/A N/A N/A SPI [W/(m3/h)] 0.12 0.12 0.12 Control Factor & Control Typology: (CTRL/ Typology) Control Factor; CTRL 1.00 0.95 0.65 Control Typology Manual Control Clock Control Local Demand Control Declared: -Max Internal & External Leakage Rates(%) for BVUs or carry over (for regenerative heat exchangers only), N/A N/A N/A -&Ext. Leakage Rates (%) for Ducted UVUs; Mixing Rate of Non-Ducted BVUs not intended to be equipped with one duct connection on either supply or N/A N/A N/A extract air side; Position and description of visual filter warning for RVUs intended for use with filters, including text pointing out the importance of regular filter changes for performance and N/A N/A N/A energy efficiency of the unit For UVUs (Instructions Install Regulated Supply/Extract Grilles Façade) In F&W In F&W In F&W Internet Address (for Disassembly Instructions) www.ventaxia.coaxia.coaxia.com www.vent- www.vent- Sensitivity p. Variation@+20/-20 Pa: (for Non-Ducted Vus) N/A N/A N/A Air Tightness-ID/OD-(m3/h) (for Non-Ducted Vus) N/A N/A N/A Annual Electricity Consumption: AEC (kwh/a) 1.63 1.51 0.86 Annual Heating Saved: AHS (kwh/a) AHS: Average 13.97 15.72 26.23 AHS: Warm 6.32 7.11 11.86 AHS: Cold 27.32 30.75 51.31

Notes:-

Notes:-

The Guarantee Applicable only to products installed and used in the United Kingdom. For details of guarantee outside the United Kingdom contact your local supplier. Vent-Axia guarantees its products for two years from date of purchase against faulty material or workmanship. In the event of any part being found to be defective, the product will be repaired, or at the Company s option replaced, without charge, provided that the product:- Has been installed and used in accordance with the instructions given with each unit. Has not been connected to an unsuitable electricity supply. (The correct electricity supply voltage is shown on the product rating label attached to the unit). Has not been subjected to misuse, neglect or damage. Has not been modified or repaired by any person not authorised by the company. IF CLAIMING UNDER TERMS OF GUARANTEE Please return the complete product, carriage paid to your original supplier or nearest Vent-Axia Centre, by post or personal visit. Please ensure that it is adequately packed and accompanied by a letter clearly marked Guarantee Claim stating the nature of the fault and providing evidence of date and source of purchase. The guarantee is offered to you as an extra benefit, and does not effect your legal rights Head Office: Fleming Way, Crawley, West Sussex, RH10 9YX. UK NATIONAL CALL CENTRE, Newton Road, Crawley, West Sussex, RH10 9JA SALES ENQUIRIES: Tel: 0844 8560590 Fax: 01293 565169 TECHNICAL SUPPORT: Tel: 0844 8560594 Fax: 01293 532814 As part of the policy of continuous product improvement Vent-Axia reserves the right to alter specifications without notice. 449631 F 0717