Accessories DESK TOP CONTROLS MODELS SPECIFICATIONS MODELS SPECIFICATIONS UNDER DESK TOP MOUNTING MINI DESK TOP CONSOLE

Similar documents
Accessories. Desk Top Controls

Accessories. Desk Controls. Break Glass Emergency Door Release SECURITY DOOR CONTROLS

Accessories. Desk Controls. Break Glass Emergency Door Release SECURITY DOOR CONTROLS

Exit Switches 410 & 420 SERIES MODELS SPECIFICATIONS HOW TO ORDER 1 SPECIFY MODEL 2 SPECIFY FINISHES 3 SPECIFY OPTIONS

Egress Devices for Code Compliant Access-Controlled Egress Doors

Exit Switches SECURITY DOOR CONTROLS. 400 Series 410 & 420 Series. Finishes. Finishes. Options. Options. Specifications.

Code Compliance. Selected Exit Check models are available to comply with one or more codes listed below. See Operation on page 3.

Multi-Mode Annunciators

Exit Check Integrated Delayed Egress Locks

LOCK INTO THE ACSI ADVANTAGE LOCK INTO THE ACSI ADVANTAGE

PoE SOLUTIONS Power over Ethernet Capable Locking Hardware SOLUTIONS

EXIT CHECK DELAYED EGRESS LOCKS

Exit Check Integrated Delayed Egress Locks

QUIET DUO LR100 SERIES

Power Transfer Devices. Access Control Accessories. How To Order. How to Order

Exit Check Integrated Delayed Egress Locks

Optional cable and connectors SELECTRIC TM PRO

LR100 24V Latch Retraction / Dogging Kit

POWER TRANSFERS ACCESSORIES EAC. Manufacturer Product Product No. Product Description Item No.

LR100 24V Latch Retraction / Dogging Kit

ACCESS & EGRESS REMOTE CONTROLS SOLUTIONS. The lock behind the system. SDCSecurity.com

Innovative Access & Egress Solutions. Security Door Controls Condensed Catalog. Copyright 2014, Security Door Controls. US Made

Delayed Egress System DORMA EMDE

UNIVERSITY OF ROCHESTER DESIGN STANDARDS FEBRUARY 2005MARCH 2007

Security Professional Mobile Showroom. Product Training

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

System components portfolio overview. Power supplies, electromagnetic locks, electric strikes and system accessories

300 SERIES MINI MAGNETIC LOCK 1000 SERIES INDUSTRIAL MAGNETIC LOCK 1100 SERIES ARCHITECTURAL MAGNETIC LOCK 1100 SERIES MORTISE MAGLOCK & DOOR PULL

CHECK NEW PRODUCTS SECTION FOR NEW INNOVATIVE SOLUTIONS

POWER SOURCES MODEL NO. DESCRIPTION PRICE

300 SERIES MINI MAGNETIC LOCK 1000 SERIES INDUSTRIAL MAGNETIC LOCK 1100 SERIES ARCHITECTURAL MAGNETIC LOCK 1100 SERIES MORTISE MAGLOCK & DOOR PULL

ABLOY EFEND. New name for security

Delayed Egress Locks 38 SECURITY DOOR CONTROLS

631RF Amp Power Supply

SECTION DOOR HARDWARE

White Papers: Delayed Egress Hardware

Series Electric Hinges/Pivots Hager Ives McKinney Stanley PBB Bommer Rixson ABH and more

Is the Key! Premium Grade Access Control Hardware

ACCESS & EGRESS LOCKING DEVICES SOLUTIONS. 1.2 Delayed Egress Locks. The lock behind the system. SDCSecurity.com

INSTALLATION INSTRUCTIONS 101-DE/101-KDE

300 SERIES MINI MAGNETIC LOCK 1000 SERIES INDUSTRIAL MAGNETIC LOCK 1100 SERIES ARCHITECTURAL MAGNETIC LOCK 1100 SERIES MORTISE MAGLOCK & DOOR PULL

DS160/161 Request To Exit PIR sensors Installation Instructions

DS160/DS161 Request To Exit PIR sensors Installation Instructions

Digital & Card Access Control Systems

CX-WC SERIES RESTROOM CONTROL KITS ELECTRIFIED LOCKS, RELAYS & TIMERS BARRIER FREE RESTROOM CONTROL FEATURES DESCRIPTION APPLICATION

STANDARD FEATURES SPECIFICATIONS

22-F fire exit rim device for all types of 4 x 8 (1219mm x 2438mm) single doors and 8 x 8 (2438mm

APPENDIX F: LOCKSETS AND ACCESS CONTROL

Mechanical to Electrical Making the Jump

Pilfergard Door Alarms

INSTALLATION INSTRUCTIONS EXIT CHECK DELAYED EGRESS EMLOCK 1511S / 1511T

STANLEY PATIENT SAFETY LEVER (SPSL) STANLEY SECLUSION ROOM LOCK (SSRL) STANLEY EMERGENCY DOOR ALARM (SEDA)

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

Remote Chexit Module (RCM) System. General Information

Upgrade Your Solution: Mechanical to Electrical

CX-WC SERIES RESTROOM CONTROL KITS ELECTRIFIED LOCKS, RELAYS & TIMERS BARRIER FREE RESTROOM CONTROL FEATURES DESCRIPTION APPLICATION

Mechanical to Electrical Solutions. for Aluminum and Glass Openings

Complete Component Considerations

Architect s Specification Guideline:

System Design and Overview Document

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

about HES is ISO 9001:2000 certified.

1. Items known commercially as finish hardware or builders hardware, required for swing, sliding, or folding doors.

PRODUCT INTRODUCTION

PRICELIST Access. Value. Today.

INSTALLATION INSTRUCTIONS EA SERIES DOOR PROP/EXIT ALARM

2409/2900. Fire Guard

DE5300 Delayed Egress System. General Information

2408/2900. Fire Guard

SARGENT Beacon TM. A Technical and Informational Newsletter From Dugmore & Duncan. Summer 2009 Vol. VIII - Issue II L

ED4000. Narrow Stile Pushpad Exit Devices

2408/2900. Fire Guard. SARGENT Manufacturing Company 2004, 2007 All rights reserved

Alarmed Exit Hardware

Electromechanical Locks & Exit Devices

HES and Securiton have united as ASSA ABLOY Electronic Security Hardware. Electronic Security

GATE & Fence. Solar Power Supplies. Gate Locks. Gate Lock Bracket Kits. Specialty Brackets. Power Supplies. And More...

EntryCheck E70 Series

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011

ALARMED EXIT HARDWARE

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

BEA, Inc. Microwave Detector. Infrared Detectors. Time Delays/Security Modules. Accessories

SP-1000X. Panic Device Power Controller Installation Guide. Rev

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

Modular Fillerplate Subassembly P/N: X Endcap P/N: Strike *, P/N: " Narrow Stile Plastic Template. Mortise.

Installation Instructions

705 Emmett Street Bristol, CT DynaLock MODEL 3101C-TJ101 DELAY EGRESS SYSTEM WIRING INSTRUCTIONS

UBC Technical Guidelines Section Edition Access Control Page 1 of 5

Series 98/99. All Series 98/99 are available with antimicrobial coating. (Page 38 for more detail) OPTIONS AND ACCESSORIES. Touchbar Exit Devices

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

AO19 SERIES LOW ENERGY AUTOMATIC DOOR OPERATORS

DOLKPS1KB Programming & Installation Manual

RESTROOM CONTROL KITS

5900 SERIES Low Energy Power Operator

5900 Series X-in Low Energy Power Operator

Hardwired Alarm Accessories

Electric Dogging (ED)

SECTION HARDWARE

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

DOOR HARDWARE SECTION DESIGN REQUIREMENTS GENERAL INFORMATION

Transcription:

Accessories DESK TOP CONTROLS UNDER DESK TOP MOUNTING The SDC 15 Series Switch controls are mounted on the underside of a desk for remote door control. They may be connected to the REX input of an access control or to the trigger input of a time delay relay to allow timed access and egress. The 15-2-3 is equipped with one momentary switch to provide momentary access and a toggle switch for sustained bypass. 15-1 On-off push switch, 6 Amp 15-2 Momentary push switch, 10 Amp 15-3 On-off toggle switch, 6 Amp 15-2-3 On-off toggle switch and momentary push switch, 6 Amp Contact SPDT, 6 Amps @ 30VDC Dimensions 15-2 1" H x 2.25" W x 2.5" D 15-1 / 15-3 / 15-2-3 1.125" H x 3.125" W x 1.5" D 15-2 15-1 15-3 15-2-3 MINI DESK TOP CONSOLE The SDC DT Series Consoles have a clean look for desktop applications. The heavy duty momentary push switches may be connected to the REX input of an access control or trigger input of a time delay relay. The maintained switch station may be wired to provide sustained bypass (unlock). When connected to a door status switch (DPS) or magnetic bond sensor (BAS), the bi-color LED can provide status indication of the door and/or locking device. DTMO-1 DTMO-2 DTMA-2 One Momentary station and one LED Two Momentary stations and two LEDs Two Maintained stations and two LEDs DTMOMA-2 One Momentary station and 1 maintained station and two LEDs Contact SPDT, 5 Amps @ 30VDC Dimensions 4.125 W x 3.125" H x 6.25" D LED One, tri-color LED. Illuminates red, or green or amber Finish Gloss Beige Material 0.0936" Aluminum Power 24VDC @ 0.02 Amp required for each LED DTMO-1 DTMA-1 DTMO-2 DTMA-2 DTMOMA-2 ACCESS & EGRESS SOLUTIONS - THE LOCK BEHIND THE SYSTEM 1 WWW.SDCSECURITY.COM SECURITY DOOR CONTROLS

FIRE RATED ELECTRIC POWER TRANSFER HINGES 10B Listed For 3 Hrs Fire Rated Doors FEATURES 4.5 Ft Cable UL10B Listed for 3 Hour Fire Rated Doors Wire Replacement Warranty APPLICATION Installed in the center hinge position of the door, PTH Power Transfer Hinges provide the concealed wires required to transfer power from the frame to electric hardware in the door for control and monitoring capability. PTH-4Q PTH-4Q-DPS PTH-10Q PTH-10Q-DPS Four (4) Conductor Power Transfer Hinge 1 Amp @ 12/24V per pair Four (4) Conductor Power Transfer Hinge with Door Status Contact 1 Amp @ 12/24V per pair Door Status Contact: 250 ma @ 30VDC Ten (10) Conductor Power Transfer Hinge 1 Amp @ 12/24V per pair Ten (10) Conductor Power Transfer Hinge with Door Status Contact 1 Amp @ 12/24V per pair Door Status Contact: 250 ma @ 30VDC FOR VON DUPRIN EL 33 AND 99 SERIES EXIT DEVICES AND OTHER HIGH INRUSH DEVICES The PTH-2-4 hinges have been tested with Von Duprin* EL devices and Von Duprin power booster at Underwriters Laboratories. PTH-2-4Q PTH-2-4QDPS 16 Amp Inrush, 6 Conductor Power Transfer Hinge 1-pair 16 Amp inrush, 4 Amp continuous; 2-pair 1 Amp @ 12/24V 16 Amp Inrush, 6 Conductor Power Transfer Hinge, with Door Status Contact 1-pair 16 Amp inrush, 4 Amp continuous; 2-pair 1 Amp @ 12/24V Concealed Door Position Contact, 250 ma @ 30VDC FIRE RATED CONCEALED MORTISE POWER TRANSFER PT-5 Concealed Mortise Mount Power Transfer Loop Frame mortised steel dust box with flexible steel loop and chrome finish. Recommended for use with hollow metal frames. Dimensions: 11.5 H x 1 W x 0.75 D PT-5 10B Listed For 3 Hrs Fire Rated Doors PT-2U POWER TRANSFER LOOPS PT-2U With black end caps PT-3V With aluminum wire termination box PT-3V 18 Stainless steel armored flex conduit with small plastic end caps or termination box. Recommended for use with hollow metal and aluminum frames. SECURITY DOOR CONTROLS WWW.SDCSECURITY.COM 2 ACCESS & EGRESS SOLUTIONS - THE LOCK BEHIND THE SYSTEM

EMERGENCY DOOR RELEASE The SDC 490 Series Emergency Door Release is ideal for immediate unlocking of doors that are equipped with failsafe electric locks and may influence approval of an electric lock system. The built in alarm may be used as a local door annunciator. 491 Break glass emergency door release 3V-28VDC, 18mA with siren (blue) 491-GL4 Four replacement glass plates 491-BB CSFM 3625-0324-107 Surface mount back box (blue) 492 Pull station emergency door release 3V-28VDC, 18mA with siren (blue) 492-GL4 Four replacement glass rods 492-BB Surface mount back box (blue) 491 FEATURES 491 Features Alarm 2-SPDT 10 Amp contacts Remote monitoring CCTV activation, or alarm activation Single gang box mounted Two replacement glass plates included 492 Features Alarm 2-SPDT 10 Amp contacts Blue housing with easy read activation instructions Release of one or all doors on same circuit Single gang box mounted 492 COMMUNICATING BATHROOM SYSTEMS CONTROLS CB401-AU CB402-AU CB401-B CB402-B For a common single bathroom shared by two patient rooms or dormitory rooms, the CB400A controls provides privacy and ensures that both doors are locked only when the bathroom is occupied and unlocked when the bathroom is not occupied. The CB400B controls provide emergency access by facility staff. Both doors unlock when signalled by the fire life safety system. For communicating bathroom systems with EMLock Application CB401-AU The CB401-AU is located inside the bathroom. Depressing the button locks both doors for privacy. Pressing the button again unlocks both doors ensuring both doors are unlocked when unoccupied. CB401-B The CB401-B emergency door release (2 required) is located outside the bathroom above or adjacent to the door. The illuminated push switch lens indicates the doors are locked. Depressing the push switch unlocks both doors. Additional system requirements: Two SDC EMLocks 1581-DPS 650lbs holding force or 1571-DPS 1200lbs holding force; 631RF CR access control power supply with fire alarm release input. For communicating bathroom systems with Electrified Locksets, Hi/Tower or Strike Application CB402-AU The CB402-A is located inside the bathroom. Depressing the push switch locks both doors on the outside only. Doors are always unlocked on the inside for uninhibited egress. Exiting either door causes both doors to unlock. CB402-B CB402-B emergency door release (2 required) is located outside the bathroom above or adjacent to the door. The illuminated push switch lens indicates the doors are locked. Depressing the push switch unlocks both doors. Additional system requirements: Two SDC HiTower locksets Z7250-REX or Z7850-DS ; 631RF LR access control power supply with fire alarm release input. Power transfer hinge loop required with Z7850-DS and Z7250-REX. ACCESS & EGRESS SOLUTIONS - THE LOCK BEHIND THE SYSTEM 3 WWW.SDCSECURITY.COM SECURITY DOOR CONTROLS

AUDIBLE AND VISUAL ANNUNCIATORS Stainless steel single gang or narrow frame mount annunciator assemblies. Dual voltage 12/24VDC. 400U-L2 400U-LT2 400U-L2 400U-LT1 400U-LT2 400U-RMB One red and one green LED, 1 gang One tri-color LED, illuminates red, green and yellow, 1 gang Two tri-color LED s, illuminates red, green and yellow, 1 gang Buzzer, 1 gang, 12VDC or 24VDC 400NU-RMB Buzzer, narrow 1.75 " wide, 12VDC or 24VDC 400-SN 400-RMB 400U-SN 400NU-SN 85 db siren, 1 gang, 3-28VDC, 18mA 85 db siren, narrow 1.75 " wide, 3-28VDC, 18mA TIMERS 10TD 10TD Mini Timer The SDC 10TD is a field adjustable 1-60 second miniature time delay relay designed for timed unlocking of electric locks. The 10TD Mini Timer is small enough to fit in a single gang box or inside the door frame. 10TD Specifications Contact SPDT dry, 2 Amps @ 30VDC Voltage 12/24V AC/DC @ 50mA Trigger Input N.O. (normally open) Dimensions 2.25 H x 1.5 W x 0.75 D 14-2 14-2 Seven Day, Skip-A-Day Timer The SDC 14-2 is a compact, field programmable, 7 day skip-a-day timer module recommended for automatic timed locking and unlocking of one door or all doors on the same circuit. The timer may be programmed to skip unlocking on selected days or weekends. The timer may also be installed in a power supply 14-2 Specifications Contact SPDT dry, 16 Amps @ 30VDC Voltage 12V AC/DC or 24V AC/DC please specify Dimensions 2.375 H x 2.375 W x 1.25 D REQUEST-TO-EXIT PIR SENSOR MD31D-W The SDC MD31D passive infrared detector is specifically designed for request-to-exit applications. It has an adjustable 1-60 second time delay. The coverage field is internally pointable. When angled 14º down, coverage may be 5 x 6 feet at 7 feet high to 10 x 12 feet at 15 feet high. The MD31D projects a wrap around U pattern down and away from the door to inhibit tampering. The MD31D may be mounted to the frame header, wall or ceiling. Complies with NFPA applications. MD31D-B MD31D-W MD31D-B PIR motion detector, white PIR motion detector, black Input 12 or 24VDC/VAC @ 26mA max Contact 2 SPDT dry, 2 Amp @ 30VDC Operating Temperature -20ºF to 120ºF Dimensions 1.5 H x 6.25 W x 1.5 D SECURITY DOOR CONTROLS WWW.SDCSECURITY.COM 4 ACCESS & EGRESS SOLUTIONS - THE LOCK BEHIND THE SYSTEM

EXIT DEVICE SWITCH KITS Switch Kits are field installed in the inactive hinge pad of rim mount exit devices, mortise exit devices, concealed vertical rod exit devices and surface vertical rod exit devices. Switch Contact: SPDT, 5 Amp @ 30VDC APPLICATION Activation of Delayed Egress Locks Electromagnetic Lock Release Request-to-Exit Alarm Shunt or Alarm Activation 00510 00511 00512 00514 00516 00517 00518 00519 00525 00528 00527 Model Make & Model to be Modified 00510 Von Duprin 33, 35, 98, 99 00510-2 Von Duprin 33, 35, 98, 99 DPDT 00511 Von Duprin 55 00512 Von Duprin 88 00514 Dor-O-Matic 990, 1090, 1990, 2090 00515 Sargent 9300, 9400, 9500 00516 Sargent 9600, 9700, 9800, 9900 00517 Adams Rite 8300, 8400, 8700, 8800 00518 Precision Series 1100 00518A Precision Apex Series (2100-2800) 00519 Jackson 1095 00519-2 Jackson 1095 DPDT 00520 Corbin 3000 00521 Corbin 7000 00525 Monarch 18 and 19 00525-2 Monarch 18 and 19 00526 Corbin ED8200 00527 Sargent 8800, Arrow S3800 00527-2 Sargent 80 DPDT 00528 Sargent 20/60 and Yale 2100 00531 Yale 7000 (Dogging mechanism required) Corbin 4000 00535 Kawneer Mid Panel Line Dor-O-Matic 1390 00536 Jackson 1295 00539 Cal Royal 9800 00540 Arrow 00542 Hager 4700 00590 Dor-O-Matic 1690 ACCESS & EGRESS SOLUTIONS - THE LOCK BEHIND THE SYSTEM 5 WWW.SDCSECURITY.COM SECURITY DOOR CONTROLS

LATCH AND DEADBOLT MONITORING STRIKES FEATURES Strong trigger mechanism (not vandal prone sheet metal) Fits standard ANSI 2.75 or 4.875 strike (provided by others) Cylindrical; non-handed Mortise; reversible handing Standard ANSI frame preparation Vandal resistant Wide gap alignment adjustment Horizontal alignment adjustment Compatible with: Cylindrical locksets Mortise locksets Deadbolts Mortise locksets with deadbolts MS-12 APPLICATION Delayed Egress lock activation Latchbolt status Deadbolt status Alarm shunt Alarm activation Mantrap communication Common bath door communication MS-12 SPDT Cylindrical latch monitor 2-3/4 MS-12D DPDT Cylindrical latch monitor 2-3/4 MS-14 SPDT Cylindrical latch monitor 4-7/8 MS-14D DPDT Cylindrical latch monitor 4-7/8 MS-16 SPDT Mortise lock latch monitor MS-16D DPDT Mortise lock latch monitor MS-18 SPDT Mortise lock deadbolt monitor MS-18D DPDT Mortise lock deadbolt monitor MS-20* SPDT Mortise lock latch and deadbolt monitor MS-20D* DPDT Mortise lock latch and deadbolt monitor MS-14 *MS-20 and MS-20D are handed but reversible Contact: 5 Amps @ 12/24VDC Strike plate provided by others MS-16 MS-18 MS-20 SECURITY DOOR CONTROLS WWW.SDCSECURITY.COM 6 ACCESS & EGRESS SOLUTIONS - THE LOCK BEHIND THE SYSTEM

DOOR STATUS CONTACT DPS-11 Ball Switch The SDC DPS-11 ball switch is compatible with swinging or sliding doors. Recommended uses include communicated doors, mantraps, auto re-lock switches and high current applications. DPS-11 Contact SPDT, 5 Amps @ 30VDC Faceplate 2.75 H x 1.25 W x 0.125 D Switch Depth 1.25 Finish 628 Satin Aluminum MC-4M Concealed Magnetic Contact Designed for vandal resistance, the SDC MC-4M is installed in the mortise of a hollow metal or aluminum frame and wood, hollow metal or aluminum door. MC-4M Contact SPDT, 100mA @ 30VDC Faceplate 4.875 H x 1.25 W x 0.125 D Switch Depth 0.5 Finish 628 Satin Aluminum MC-4 MC-4 Magnetic Switch - single MC-4PAK Magnetic Switch - 10 pack Ideal for door status monitoring, the SDC MC-4 is easily installed in hollow metal and aluminum doors and frames. Contact Door/Frame Preparation Gap 0.5 SPDT, 50mA @ 30VDC 0.75 diameter x 1 deep MC-7 High Security Magnetic Switch Biased for high security door status monitoring, the MC-7 guards against false status indication caused by the presence of an additional magnet. Installed in hollow metal and aluminum doors and frames. Recommended for high security applications. Contact Door/Frame Preparation Gap 0.5 SPDT, 50mA @ 30VDC 1 diameter x 1 deep MC-7

2016 SECURITY DOOR CONTROLS WWW.SDCSECURITY.COM LIT-ACCESSORIES 10/16 [t] 800.413.8783 805.494.0622 [f] 866.215.3138 801 Avenida Acaso, Camarillo, CA 93012 PO Box 3670, Camarillo, CA 93011