CORREX MP Anode with external voltage source. Installation & Operation Manual

Similar documents
Instruction Manual - Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2

OPERATING AND INSTALLATION MANUAL

OPERATING AND INSTALLATION MANUAL

Mechanical seals external, single or double, to DIN EN 12756

with insulated heating elements for water heaters INSTALLATION AND USER MANUAL WARRANTY CARD

Level Electrode NRG NRG Original Installation Instructions English

Installation and Operating Instructions

Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro

OPERATING AND INSTALLATION MANUAL

Level Electrode NRG Original Installation Instructions English

Warranty Details page 2. Pump Description & Technical page 3 Specifications. Transportation, Storage & Installation page 4. Pump Maintenance page 5

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets with screw connection (16/32 A)

Installation manual extra-low-voltage socket outlets for panel- and surface-mounting

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50

Rycroft Storage & Non-Storage Calorifiers. Installation, Operation & Maintenance Manual

Hodge Clemco Ltd. MJC Mini Cartridge Filters Owners Manual. TSOM 556 Date of issue 13/07/04. Hodge Clemco Ltd

OPERATING AND INSTALLATION MANUAL

CARVER CASCADE 2 & CASCADE 2 GE CARAVAN WATER HEATER INSTALLATION INSTRUCTIONS LEAVE THESE INSTRUCTIONS WITH THE USER

#PSBTWE1000 INSTALLATION GUIDE

USER MANUAL INSTALLATION INSTRUCTIONS WARRANTY REGISTER

Chapter 3 Cooling, heating and ventilation systems

Heat Exchanger Tube Change Procedure

BG6UL. 6 Inch Bench Grinder Assembly & Operating Instructions

SERVICE MANUAL. Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

Service Documentation Market Release 7/84. Braun Kitchen machine KM 32 B 4209 with lamp

APEX Water Filters MODEL RO 5. Treat your body to pure goodness with Apex filtered water INSTRUCTION MANUAL. pure water in every drop

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

GL190-A / GL191-A / GJ461-A

Unvented Electric Water Heater 10/15 litre Undersink

Installation and operating instructions. DK energy storage and DK energy buffer

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

Parts Available from

CHIPPER PC1 INSTRUCTIONS FOR INSTALLATION OPERATION AND MAINTENANCE. Series 35

Friwa Compact. Operating instructions EN

Powerstock Storage Tank

Conductivity Electrode LRG Original Installation Instructions English

DR. E. HORN GmbH / Schoenaich, Germany

USER S MANUAL ATH WH220

EXFG Oxygen Analyzer System. Installation Guide. EXFG Probe. ABB Process Analytics

FSW300 Series Flow Switch

Service: to SLK Laboratory Hot Plates glass made of ideas

LP30 High Integrity Low Level Alarm Probe Installation and Maintenance Instructions

Operating Instructions for the BBO-1 and BBO-2 Basket Blasters

VERTICAL COOKING PRECISIO/PRECIJET COMBI OVEN PRECISIO/ PRECIJET OVENS S.A.V. MAINTENANCE AND REPAIR

SERIES 4000 AUTO GATE MANUAL

OPERATING AND INSTALLATION MANUAL

OPERATING AND INSTALLATION MANUAL

ONE PIECE TOILET LT3. Model: MPN: B0940 INSTALLATION INSTRUCTIONS. Version: 1.0

Operating Guide. Termix Solar A+/B+ 1.0 Table of Contents. 1.0 Table of Contents

Operating Guide. Termix Compact 28 VX-FI / HWP / HWS. 1.0 Table of Contents. 1.0 Table of Contents

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWE150A3V3 EKHWET150A3V3 EKHWE200A3V3 EKHWE300A3V3

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

Venco 75mm (3 ) Standard and De-airing Pugmill

Conductive Leakage detectors of the Leckstar range

! WARNING. Replacement Head Mechanism INSTRUCTION MANUAL MM-413F

OPERATING AND INSTALLATION MANUAL

Moisture inside the drum is due to final testing.

Installation Instructions

For use with models: PGM304-1, versions M-B PGM365-1, versions M-E, M-F & M-G

FUN I / FUN U FUN I MCP / FUN U MCP FUN V / FUN V MCP

Model: 1100 Float-Controlled Condensate Trap, PN 25

MIXERS SMX10-1, SMX20-1, SMX20-2, SMX30-1 INSTRUCTION MANUAL

model No: ir20.v2 FUSE

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS

Electrical Mini Tank Water Heater anual, and Warranty nformation

SERVICE MANUAL. For Service & Parts please call APK THERMAL at or SAFETY INSTRUCTION

Audi-Larm Audible Alarm

1500W PTC element (230V)

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

1. Take the hoses and elbow out of the holders, depending on model. max. 100 cm. min. * cm

60" Lyndon Patio. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

Acrylic Claw Foot Tub

Operating and installation instructions

Camera Housing Washer Units 5 and 25 Litre

541D19 SERIES. Technical Manual. A Division of Aquion Partners L.P.

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

NRG NRG NRG NRG

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR COMMERCIAL INDIRECT POWERED WATER HEATER

INSTALLATION AND USER INSTRUCTION MANUAL RENCOOL ECK4-48

PVC Ductwork Model. Installation and Maintenance for

SECTION air supply system + WARNING: + NOTE: GENERAL DESCRIPTION COMPRESSED AIR RESERVOIRS / 1.

Specifications. Vacuum motor power consumption(w/hp) 1200 / 1.6. Exhaust water pump power consumption(w/hp 800 / 1.1

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets QUICK-CONNECT (63 A)

SUBCOURSE EDITION EN US ARMY ENGINEER SCHOOL PLUMBING FIXTURES (PLUMBING IV)

AXPR Wall Mounted Axial Panel Fans

Marley X7 Fan USER MANUAL DESIGNED FOR INDUCED-DRAFT COOLING TOWER APPLICATIONS

GB User and maintenance manual

Operating and installation instructions

MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS

hp Dust Collector With Vacuum Attachment

Drain Cleaning Machine K-39

OPERATING AND INSTALLATION MANUAL

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

UL U TR LTRASONIC S ONIC SCALE ALER PIEZO MINI

Transcription:

CORREX MP Anode with external voltage source Installation & Operation Manual

Contents 1 Safety instructions... 3 2 Use in accordance with designated purpose... 5 3 Function... 5 4 Volume of the delivery... 5 4.1 Fitting into a tank sleeve... 5 4.2 Fitting into an insulated hole... 6 5 Fitting and putting into operation... 6 5.1 Fitting into a tank sleeve... 6 5.2 Fitting into an insulated hole... 8 6 Operation & Maintenance by the keeper... 10 7 Troubleshooting... 10 8 Technical Data... 11 These fitting and operation instructions apply to the below anode rods CORREX MP with an external voltage supply: Fitting into a tank sleeve a) by means of stop screw G 3/4 b) by means of stop screw G 1 c) by means of stop screw G 1 1/4 Fitting into an insulated hole Potenciostat CORREX MP is supplied with various anode types. Accumulation water heater producers provide information about which anode type is suitable. They also specify details regarding the necessary size of anode for a particular accumulator. This applies in particular to additional equipment of old tanks with anodes. Whilst choosing the right type, one has to consider the recommendations of the manufacturers on anode selection. 2

1 Safety instructions Fitting and potential repairs of anode rods CORREX MP with an external voltage supply shall only be carried out by authorised experts! Prior to the fitting of a CORREX MP device, the following has to be ensured: anode rod has been operated in a closed and dry room line voltage corresponded with the value stated on the type plate line voltage was connected permanently. To ensure trouble-free function of anode rod CORREX MP, it is absolutely necessary to follow the below safety instructions: Accumulation water heater must not be in service more than 2 months without any water withdrawal, otherwise disturbing gas concentrations may occur. The potentiostat device must not be pulled out of the socket if the accumulator is full. Disconnection interrupts anticorrosion protection. Connecting cables must not be disconnected if the accumulator is full, otherwise anticorrosion protection stops working. Anode rod CORREX MP with an external voltage source must not be put out of service even in case of longer inactivity of the heater (e.g. during a holiday), since this would interrupt anticorrosion protection. WARNING! During operation of anode rod with an external voltage source in enamelled water heater tanks with an electric tubular heating element bear the following in mind: In accumulation water heaters with separately mounted electric tubular heating element, bringing voltage by means of water to the metal parts of the tank we touch cannot be eliminated in case of a defect on the electric tubular heating element. If we touch those parts, a fatal electric injury may happen under certain circumstances. Therefore, regular maintenance of the electric heating element by an expert, e.g. plumber, is required. Thus trouble-free condition of the element in terms of its outer state and function will be ensured. In case of a defect on the electronic heating element voltage may also exist on the anode rod and the connecting cable between the anode and the potentiostat. If we touch those live parts, a fatal electric injury cannot be eliminated, either. Therefore the voltage to the tubular electronic heating element has to be disconnected before each performance of works on anode rod. 3

4

2 Use in accordance with designated purpose Anode rod CORREX MP with external voltage source serves cathode anticorrosion protection of the enamelled hot water accumulators of capacity up to 300 litres, without the need of maintenance. The appliance shall only be used for the above purpose, whilst meeting these fitting and operation instructions. We do not accept any liability for damages caused in consequence of improper use or failure to meet the said manuals! 3 Function Anode rod CORREX MP with external voltage source consists of mini-potentiostat and titanium electrode that are interconnected via a connecting cable. Current from external source is generated by mini-potentiostat, protective current is supplied into the accumulator by means of titanium electrode immune from wear. The system operates as a so-called intermittent potentiostat, i.e. protective current supply by titanium electrode is interrupted regularly in short intervals. During that interruption, the potential between the titanium electrode and the inner wall of the water accumulator is measured, and the final value is brought is the actual voltage into the mini potentiostat. There it is compared to the desired set voltage inside the appliance. The protective current supplied is then set automatically so that the potential corresponded with the value required. If the potential of the tank is U H < -530 mv, the corrosion activity is almost zero. 4 Volume of the delivery 4.1 Fitting into a tank sleeve Prior to the fitting, check the volume of the delivery in terms of completeness, and the parts for intactness using the below table, as well as the figure on page 3! Item Quantity Description 1 1 Titanium electrode with separately mounted stop screw 2 1 Connector bushing with electronic intermitting potentiostat and indicator lamps 3 1 Connecting cable with terminals 5

4.2 Fitting into an insulated hole Prior to the fitting, check the volume of the delivery in terms of completeness, and the parts for intactness using the below table, as well as the figure on page 46! Item Quantity Description 1 1 2 1 3 1 Titanium electrode with screw and sealing washer Connector bushing with electronic intermitting potentiostat and indicator lamps Connecting cable with connecting terminals A bag containing: 4 1 1 gasket (Viton) 1 insulation sleeve 1 zinc-plated washer 1 geared washer M8 2 hexagonal nuts M8 1 geared washer with flat contact 6.3 x 0.8 mm 5 Fitting and putting into operation 5.1 Fitting into a tank sleeve During the fitting, do not forget to consider the following safety instructions: If magnesium anode rod is present, dismantle it prior to fitting the CORREX MP anode rod (the case of additional equipment) Never connect CORREX MP potentiostat to magnesium anode rod Titanium electrode must not have any direct contact with the parts built in the accumulator or in the wall of the accumulator Check whether the insulation is perfect, using a suitable gauge. The function of anode rod CORREX MP with external voltage source is only guaranteed on condition of perfect connection of the conductive metals of all electric connections. Check whether the conductivity of the connections is perfect, using a suitable gauge. Use only genuine connecting cables. In no case extend the connecting cables. Prior to putting into operation check whether the cable connections are not exchanged. If so, there is a danger of corrosion. To ensure ideal seating of the sealing ring, the edge of the tank sleeve has to be bevelled by 60. 6

In case of additional assembly of the anode rod to an external voltage source, the existing sleeves with thread or reductions can be used (zinc-plated steel). Fitting and putting into operation The graphics on the folded side in the beginning of these manuals illustrates assembly of the anode to an external voltage source. The real situation depends on the heater type and its size. Let the folded side (page 3) open during the assembly. What you need for the assembly: titanium electrode with stop screw G 3/4, G1 or G 1 1/4 (1); supply cable (3) potentiostat (2) Proceed as follows during the assembly of the anode rod: Drain the water accumulator (if necessary) Dismantle the old anode rod (if necessary, e.g. in case of additional equipment) Screw the titanium electrode (1) pressure tight (up to the spigot) into the threaded sleeve of the accumulator The stop screw is provided with a PTFE sealing ring. If this sealing ring is damaged, which may occur e.g. after several screw-ins, you have to ensure the sealing function using other materials, such as cannabis or a PTFE sealing tape. Slip the flat sleeve 6.3 x 0.,8 (4) over the flat contact (5) of the geared anode washer (6). Fasten the flat plug(7) of the cable end marked as attachment to the tank frame to the earth bolt (8) of the tank. If there is not earth bolt, an alternate reliable electric cable contact of the frame to the accumulator has to be made. Without perfect connection of the conductive metal the function of the CORREX MP anode rod with external voltage source cannot be guaranteed. Insert the two-pole connector (9) of the connecting cable as far into the potentiostat socket (10) that the wedge projection snaps in. Due to using different terminals, the original connecting cable is safe against polarity reversing. Insert the potentiostat plug (2) into the 230 V power socket. Fill the accumulator with water and retest if it is tight. Check the indicator lamps on the potentiostat casing. Anode rod begins to work only if the accumulator is filled with water. If the green indicator light (12) is on, the protective current is fed. If neither indicator light is on, the power supply is probably disconnected. If the red indicator light (11) is on, a faulty function has occurred. In that case, the checks described on page 10 have to be performed. 7

5.2 Fitting into an insulated hole During the fitting, do not forget to consider the following safety instructions: If magnesium anode rod is fitted, dismantle it prior to fitting the CORREX MP anode rod (the case of additional equipment). Never connect the CORREX MP potentiostat to magnesium anode rod. Titanium electrode must not have any direct contact with the parts built in the accumulator or in the wall of the accumulator Check whether the insulation is perfect, using a suitable gauge. The function of the CORREX MP anode rod with external voltage source is only guaranteed on condition of perfect connection of the conductive metals of all electric connections. Check whether the conductivity of the connections is perfect, using a suitable gauge. Use genuine connecting cables only. In no case extend the connecting cables. Prior to putting into operation check whether the cable connections are not exchanged. If so, there is a danger of corrosion. Use genuine sealing material only. In case of additional assembly of the anode rod to an external voltage source, the existing bushings after previously separately mounted anode rods can be used. Fitting and putting into operation The graphics on the folded side in the beginning of these manuals uses examples to illustrate the assembly of the anode to an external voltage source. The real situation depends on the heater type and its size. Let the folded side (page 46) open during the assembly. What you need for the assembly: titanium electrode (1) supply cable (3) potentiostat (2) 1 gasket (Viton) (4) 1 insulation sleeve (5) 1 zinc-plated washer (6) 1 geared washer M8 (7) 2 hexagonal nuts M8 (8 & 10) 1 geared washer with flat contact 6.3 x 0.8 mm (9) 8

Proceed as follows during the assembly of anode rod with an external voltage source: Drain the water accumulator (if necessary) Dismantle the old anode rod (if necessary, e.g. in case of additional equipment). If there is no hole, bore a hole of 10.5 mm diameter into the accumulator flange cover. Slip the Viton gasket (4) over the titanium electrode screw thread (1) and run the electrode from the inner side through the hole that is prepared for the assembly. Insert the insulation sleeve (5) from the outer side of the flange cover or more precisely wall of the tank. Screw in the titanium electrode with washer (6), geared washer (7) and hexagonal nut (8). The screwing has to be pressure-tight (the torque recommended is 6 Nm). Use a wrench! Insert the geared washer with flat contact 6.3 x 0.8 mm (9) and lock it with the hexagonal nut (10). Re-fix the flange with titanium electrode to the accumulator. Fasten the flat plug (11) of the cable end marked as attachment to the tank frame to any of the flange bolt (8) of the tank. If there is not earth bolt, an alternate reliable electric cable contact of the frame to the accumulator has to be made. Without perfect connection of the conductive metal, the function of the CORREX MP anode rod with external voltage source cannot be guaranteed. Slip the flat sleeve 6.3 x 0.,8 (12) over the flat contact of the geared anode washer. Insert the connector (13) of the connecting cable as far into the potentiostat socket (14) that the wedge projection snaps in. Due to using different terminals, the original connecting cable is safe against polarity reversing. Insert the potentiostat plug (2) into the 230 V power socket. Fill the accumulator with water and retest if it is tight. Check the indicator lamps on the potentiostat casing. Anode rod begins to work only if the accumulator is filled with water. If the green indicator light (15) is on, the protective current is fed. If neither indicator light is on, the power supply is probably disconnected. If the red indicator light (16) is on, a faulty function has occurred. In that case, the checks described on page 10 have to be performed. 9

6 Operation & Maintenance by the keeper The CORREX MP anode rod is immune to wear and operates without the need of maintenance. You only need to check the control lights, from time to time. If the green indicator light is on, feeding of the protective current is in process. If neither indicator light is on, call a technician or our customer service. If the red indicator light is on, call a technician or our customer service. To ensure trouble-free function of the CORREX MP anode rod, it is absolutely necessary to follow the below safety instructions: Water heater must not be in service more than 2 months without any water withdrawal. Otherwise disturbing gas concentrations may occur. The CORREX MP potentiostat device must not be pulled out of the socket if the water accumulator is full. Disconnection from power supply interrupts anticorrosion protection. Connecting cables must not be disconnected if the water accumulator is full, otherwise anticorrosion protection stops working. Anode rod CORREX MP with an external voltage source must not be put out of service even in case of longer inactivity (e.g. during a holiday), since this would interrupt anticorrosion protection. Only pull out the bushing with the plug or the connecting cable if the accumulator is empty. Power consumption is below 35 kwh / year. 7 Troubleshooting The below described measures to remove failures shall only be performed by a technician or experts of our customer service! If neither indicator light is on, the power supply is probably disconnected. If the red indicator light is on, perform the following checks: Is the water accumulator filled with water? Fill water in the water accumulator! Is electric clearness ensured? Check all connections and contacts in terms of perfect and conductive metal contact. Remove potential defects. Is there an old magnesium anode fitted inside the accumulator? If so, dismantle it. Is perfect insulation of the electrode or more precisely of the in-built accessories - from the wall guaranteed? Check the insulation using a gauge with the accumulator empty and, if necessary, correct the position of the accessories and/or of the electrode. 10

In terms of electric insulation, has the assembly of other than enamelled heat exchangers of the heater been performed correctly (e.g. copper finned tubes, copper smooth tubes or chromiumnickel smooth tubes)? Check the insulation using a suitable gauge and, if necessary, remove the defect. If the above measures do not help to remove the defect of the CORREX MP anode rod, contact the accumulator supplier. 8 Technical Data Mini potentiostat CORREX MP Potentiostat with a plug for cathode anticorrosion protection of enamelled electric water heaters (intermitting potentiostat with Function controlled regulation of protective current potentiostat) with an integrated function indication with red/green LED control lights. Voltage: 230 V ± 10 % Mains power supply Frequency: 50/60 Hz Power input: < 4 VA Požadovaný potenciál: 2,3 V ± 50 Ev Impulse frequency: 100 Hz Indicators Intermittence: 200 µs Rated current (secondary) 100 ma Supply voltage (secondary): max 10.6 V at 100 ma Display Two LEDs, 5 mm diameter Green: followed by protective current supply Red: failure Operation Bushing Temperature range (Potentiostat): IP protection: Dimensions (without Euro socket plug): Weight (without anode cable) neither is on: no power supply 0...40 C II (operation in closed rooms) L x W x H = 80 x 50 x 45 mm approx. 160 g Titanium electrode CORREX Function Supply and referential electrode with a coating of noble metal oxides; supply with protective current without wear; referential electrode to measure the actual potential in the accumulator. Bolt with thread M8 x 30 Dimensions of electrode in the Diameter: 2 mm part filled with water Délka: 200 mm (Basic MP version) Coating length: 100 mm Assembly options: Fitting into a sleeve Fitting into an insulated hole 05-2012 11